Swimming Pool Type Heat Pump Water Heater Technical Manual

Download as pdf or txt
Download as pdf or txt
You are on page 1of 65
At a glance
Powered by AI
The manual provides specifications, dimensions, installation instructions, operating instructions, and troubleshooting information for Midea's swimming pool heat pump water heaters.

The main components described include the outdoor units, installation requirements, water piping diagram, electric connections, and controller interface.

The modes of operation described include cooling, water heating, pumping, and standby. It also covers operating instructions for different unit capacities.

Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

Midea Swimming Pool Type


Heat Pump Water Heater
Technical Manual

Applicable Models:
LRSJ-60/NYN1 LRSJ-80/NYN1
LRSJ-120/NYN1 LRSJ-140/NYN1

Applicable Models:
LRSJ-900/SY LRSJ-450/SY
Midea reserves the right to discontinue, or change at any time, specifications or designs without notices and
without incurring obligations.

1
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

Contents
Part 1 General Information .................................................. 3

1. Measurements ................................................................................ 4
2. External Appearance ..................................................................... 4
3. Nomenclature ................................................................................. 5
4. Features .......................................................................................... 6
Part 2 Outdoor Units ............................................................ 7

1. Specifications................................................................................. 8
2. Capacity & COP curve ................................................................. 10
3. Dimensions................................................................................... 19
4. Service Space ............................................................................... 21
5. Wiring Diagrams .......................................................................... 22
12Kw and 14Kw wiring diagrams: .......................................... 23
Part 3 Installation ............................................................... 45

1. Precautions .................................................................................. 46
2. Installation information ............................................................... 47
3. Unit Appearance........................................................................... 48
4. Accessories .................................................................................. 50
5. Inspecting and Handling the Unit ............................................... 50
6. Water pipeline diagram ................................................................ 51
7. Water pump selection .................................................................. 52
8. Tools required for installation ..................................................... 52
9. Electric connection ...................................................................... 52
Part 4 Trial Operation ........................................................ 54

1. Confirmation Before the Trial Operation .................................... 55


2. Operating Instruction .................................................................. 55
2.1 Operating Instruction for 6KW,8KW,12KW,14KW .................... 55
2.2 Operating Instruction for 45KW,90KW ..................................... 58
2.2.1 The appearance of controller ................................................. 58

2
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

Part 1
General Information
1. Measurements .................................................................. 4

2. External Appearance ....................................................... 4

3. Nomenclature ................................................................... 5

4. Features ............................................................................ 6

3
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

1. Measurements

Dimension Net weight / Gross weight


Model Power Supply
(mm: W*H*D) (kg)
CE-LRSJ-60/NYN1 1015*705*385 60/64 220~240V-1ph-50Hz

CE-LRSJ-80/NYN1 1015*705*385 62/66 220~240V-1ph-50Hz

CE-LRSJ-120/NYN1 1050*855*315 75/85 220~240V-1ph-50Hz

CE-LRSJ-140/NYN1 1050*855*315 75/85 220~240V-1ph-50Hz

LRSJ-450/SY 1514*1820*850 380/400 380~420V-3ph-50Hz

LRSJ-900/SY 2000*1970*900 580/650 380~420V-3ph-50Hz

2. External Appearance

LRSJ-60/NYN1 LRSJ-80/NYN1 LRSJ-120/NYN1 LRSJ-140/NYN1

LRSJ-900/SY LRSJ-450/SY

4
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

3. Nomenclature Cooling recovery code

Household Water Heating Unit

1 - 2 3 4 - 5 / 6 7 8 9 10 11 - 12
Design code
Water heating unit code Refrigerant code
Water supply pump lift code
Other functions code
Power supply specification code
Heating mode code
whether the system with pump
Rated hot water output, unit: 100 W
Installation type code
cooling recovery code
Export model code
Export model code

For example:

L RSJ - 60 / N Y N1

Refrigerant type :R410a

Heating mode code:swimming pool

No water pump with machine

Rated hot water output, unit: 100 W

Water heating unit code

With cooling function

5
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

4. Features
4.1 Titanium heat exchanger
a. Excellent prevent eroding material, keep the machine long life.
b. High energy efficiency.

4.2 LCD display and build in high pressure meter in refrigerant side
User can see the machine running parameter and the state quickly.
Engineer can see the machine discharge pressure quickly, get hold of the machine
running reliably.
4.3 About the 3-minute protection
Restart or open the manual switch after the unit has shut down, unit will not start immediately until 3 minutes
later, because of the self-protect function of the compressor.
4.4 Defrosting function
In case of the unit requiring deicing during heating operation, to prevent the heating efficiency from decreasing,
defrosting operation will turn on automatically (approx. 2~8 minutes) .
In the process of defrosting operation, the unit air supply motor will stop running.
4.5 Safety
a. Realize isolation between water and electricity. No electric shock problem, more safety.
b. No fuel tubes and storage, no potential danger from oil leakage, fire, explosion etc.

4.6 Automatic Control:


Automatic start-up and shutdown, automatic defrosting by revising refrigerant cycle. Save you much extra
operation.
4.7 R410a gas, Environmental protection (except LRSJ-450/SY & LRSJ-900/SY)
a. No discharge of poisonous gas.
b. No pollution to atmosphere and environment

4.8 All-the-weather Running.


Within the temperature range from -7℃ to 43℃, it will not be affected by night, cloudy
sky, rain even snow weather.

6
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

Part 2
Outdoor Units
1. Specifications................................................................... 8
2. Capacity & COP table .................................................... 19
3. Dimensions .................................................................... 19
4. Service Space................................................................. 21
5. Wiring Diagrams ............................................................ 22
6. System refrigerant Diagrams ........................................ 27
7. Exploded View ............................................................... 27
8. PCB explain .................................................................... 27

7
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

1. Specifications
HPWH SPECIFICATION
Model CE-LRSJ-60/NYN1 CE-LRSJ-80/NYN1 CE-LRSJ-120/NYN1 CE-LRSJ-140/NYN1
Power supply Ph-V-hz 1-230-50 1-230-50 1-230-50 1-230-50
Capacity kW 6 8 12 14
Water Input kW 1.15 1.52 2.40 2.55
Heating Outdoor ambient
(-7℃~38℃) (-7℃~38℃) (-7℃~38℃) (-7℃~38℃)
temperature
Capacity kW 4.0 5.8 8.4 10.4
Water Input kW 1.3 1.5 2.4 2.9
Cooling Outdoor ambient
(15℃~43℃) (15℃~43℃) (15℃~43℃) (15℃~43℃)
temperature
COP 5.2 5.3 4.9 5.3
Max power kW 1.7 2.0 3.3 3.8
Outdoor noise level dB(A) 58 58 58 58
Refrigerant type/Quantity Kg R410A/1.0 R410A/1.25 R410A/1.6 R410A/1.85
Heat exchanger Titanium-tube Titanium-tube Titanium-tube Titanium-tube
material thermal exchanger thermal exchanger thermal exchanger thermal exchanger
Water inlet and
outlet pipe mm DN50 DN50 DN50 DN50
diameter
Drain pipe
DN25 DN25 DN25 DN25
diameter mm
Max. pressure MPa 0.4 0.4 0.4 0.4
Fin type Hydrophilic Hydrophilic Hydrophilic Hydrophilic
Air side aluminium aluminium aluminium aluminium
exchanger Tube outer type innergroove tube innergroove tube innergroove tube innergroove tube
Air outflow mode air flow from rear air flow from rear air flow from rear air flow from rear
Dimension
(W*H*D) mm 1015*705*385 1015*705*385 1050*855*315 1050*855*315
Outdoor Packing
unit (W*H*D) mm 1095*755*455 1095*755*455 1170*905*410 1170*905*410
Net/Gross weight kg 60/64 62/66 75/85 75/85
Water contented capacity (m3) 40.0 50.0 60~85 75~100
3
Hot Water Yield m /h 2.3 2.8 3.8 3.8
Wire controller KJR-08B KJR-08B KJR-08B KJR-08B
(default)28℃, (default)28℃, (default)28℃, (default)28℃,
Water Heating Outwater Temp ℃ 20℃~35℃ 20℃~35℃ 20℃~35℃ 20℃~35℃
(default)28℃, (default)28℃, (default)28℃, (default)28℃,
Water Cooling Outwater Temp ℃ 10℃~30℃ 10℃~30℃ 10℃~30℃ 10℃~30℃
Applicable range 40 50 60-85 75-100
m3
Compressor current protection 10 12 20 22
value A

Remark:
1. The test conditions: outdoor temp.
Water Heating: outdoor temp. 24/19℃(DB/WB), inlet water temp. 27℃,outlet water temp. 29℃
Water Cooling: outdoor temp. 35/24℃(DB/WB), inlet water temp. 27℃
2. The specification may be changed for product improvement, please refer to the nameplate.

8
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

HPWH SPECIFICATION
Model LRSJ-450/SY LRSJ-900/SY
Power supply Ph-V-hz 3-380-50 3-380-50
Capacity kW 45 90
Water
Input kW 8.5 16.4
Heating
Outdoor ambient temperature (-7℃~43℃) (-7℃~43℃)
Capacity kW 40 80
Water
Input kW 11.5 20.5
Cooling
Outdoor ambient temperature (21℃~43℃) (21℃~43℃)
COP 5.2 5.3
Max power input kW 14 24.8
Outdoor noise level dB(A) 65 67
Refrigerant type/Quantity Kg R22/3.5*2 R22/7*2
Titanium-tube thermal Titanium-tube thermal
Heat exchanger material
exchanger exchanger

Water inlet and outlet pipe diameter mm DN50 DN100

Drain pipe diameter mm DN25 DN25


Max. pressure MPa 0.4 0.4
Fin type
Air side Hydrophilic aluminium Hydrophilic aluminium
exchanger Tube outer type innergroove tube innergroove tube
Air outflow mode air flow from top air flow from top
Dimension (W*H*D) mm 1514*1820*850 2000*1970*900
Outdoor
Packing (W*H*D) mm 1620*2041*1034 2150*2110*1000
unit
Net/Gross weight kg 380/400 580/650
3
Hot Water Yield m /h 15 30
Wire controller KJR-08B KJR-08B
(default)28℃,20℃~
(default)28℃,20℃~40℃
Water Heating Outwater Temp ℃ 40℃
(default)28℃,10℃~
(default)28℃,10℃~30℃
Water Cooling Outwater Temp ℃ 30℃
Applicable range 100 200
m3

Compressor current protection value A

9
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

2. Capacity & COP curve

10
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

MODE : 6 kw

11
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

12
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

MODE :8 kw

13
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

14
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

MODEL :12 kw

15
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

16
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

17
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

Model: 45KW

LRSJ-450/SY

70000 7
60000 6
50000
5
Capacity (W)

COP (W/W)
40000 Ambient temp.
4
30000 Capacity
3 COP
20000
2
10000
0 1

-10000 -7 0 7 15 20 24 30 35 43 0
Ambient temperature (℃)

Test condition: water heating model, ambient temperature 24/19℃(DB/WB), water inlet
temperature 27℃, water outlet temperature 29℃

Ambient temp.(℃) -7 0 7 15 20 24 30 35 43
Capacity (W) 18180 25660 31550 37474 42719 47350 53189 57229 60223
COP (W/W) 2.51 3.2 3.9 4.65 5.2 5.5 6.1 6.4 6.5

Model: 90KW

LRSJ-900/SY

120000 6
100000 5
80000
Capacity (W)

4
COP (W/W)

60000 Ambient temp.


3 Capacity
40000 COP
2
20000

0 1
-7 0 7 15 20 24 30 35 43
-20000 0
Ambient temperture (℃)

Test condition: water heating model, ambient temperature 24/19℃(DB/WB), water inlet
temperature 27℃, water outlet temperature 29℃

Ambient temp.(℃) -7 0 7 15 20 24 30 35 43
Capacity (W) 43419 48522 67915 78134 89719 94813 97357 98229 99697
COP (W/W) 2.93 3.46 4.45 4.86 5.22 5.5 5.51 5.54 5.56

18
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

3. Dimensions

MODEL 6KW 12KW


8KW 14KW
A 610 590
B 390 333
C 170 165
D 1015 1050
E 385 315
H 705 855

19
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

20
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

4. Service Space

LRSJ-60/NYN1 LRSJ-80/NYN1 LRSJ-120/NYN1 LRSJ-140/NYN1

21
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

5. Wiring Diagrams
6Kw and 8Kw wiring diagrams:

22
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

12Kw and 14Kw wiring diagrams:

23
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

45kw wiring diagrams:

24
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

90 kw wiring diagrams:

25
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

6. System Refrigerant Diagrams

Tout

four-way titanium heat


valve exchanger
Tp T6

water
high pressure pump
protection valve

evaporator
comp. T4

T3

泳池系列系统图

26
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

7. Exploded View
MODEL: LRSJ-60/NYN1

27
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

No. Part Name BOM code Quantity No. Part Name BOM code Quantity
Titanium heat exchanger
1 201790590014 1 12 Wire controller 203355100539 1
components
2 Rear right clapboard 201290590132 1 13 Front right clapboard 201290590133 1

3 Right cover 201290590134 1 14 Wire controller box ass'y 201190590054 1


Oil-filled high pressure
4 201800100017 1 15 Axial flow fan 201100300102 1
gauge
5 Drain stop up 201690502080 1 16 Front panel 201248100024 1

6 Cable Gland 201101000005 1 17 Grille 201148350005 1

7 Compressor 201400600690 1 18 Motor 202400400579 1

8 Capillary ass'y 201690590319 1 19 Motor bracket ass'y 201290590130 1

9 Base ass'y 201290590135 1 20 Left holder 201248100022 1

10 E-part box ass'y 203390590062 1 21 Condenser ass'y 201590590016 1

10 Main control board ass'y 201390590016 1 22 Rear net 201190590053 1


Middle connection board
10 201390500120 1 23 4-way valve ass'y 201690590322 1
ass'y
10 Relay 202300800071 1 24 Partition board 201290590122 1

10 Motor capacitor 202401100505 1 25 cover 201290590129 1

11 Transformer 202300900109 1 26 Temperature sensor 202301300303 2

11 Compressor capacitor 202401000610 1 27 Temp.sensor ass'y 202301300437 1

11 Contactor 202300850043 1 28 Discharge temp sensor ass'y 202301300130 1

11 Wire joint 202301450130 1 29 room temp sensor ass'y 202301300197 1

11 Wire joint 202301450115 1 30 Compressor electric heater 202403100104 1

10 Wire clamp 201219900001 2 31 Rear net frame 201245500029 1

10 Wire joint 201135000004 2 32 Target Flow Switch 202301800829 1

11 Handle 201148700005 2 33 Compressor wire joint ass'y 202490590040 1

28
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

MODEL: LRSJ-80/NYN1

29
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

No. Part Name BOM code Quantity No. Part Name BOM code Quantity
Titanium heat exchanger
1 201790590014 1 12 Wire controller 203355100539 1
components
2 Rear right clapboard 201290590132 1 13 Front right clapboard 201290590133 1
3 Right cover 201290590134 1 14 Wire controller box ass'y 201190590054 1
4 Oil-filled high pressure gauge 201800100017 1 15 Axial flow fan 201100300102 1
5 Drain stop up 201690502080 1 16 Front panel 201248100024 1
6 Cable Gland 201101000005 1 17 Grille 201148350005 1
7 Compressor 201400620160 1 18 Motor 202400400579 1
8 Capillary assembly 201690590293 1 19 Motor bracket ass'y 201290590130 1
9 Base assembly 201290590131 1 20 Left holder 201248100022 1
Electrical controlling box
10 203390590061 1 21 Condenser ass'y 201590590016 1
ass'y
10.1 Main control board ass'y 201390590016 1 22 Rear net 201190590053 1
10.2 Middle connection board ass'y 201390500120 1 23 4-way valve ass'y 201690590299 1
10.3 Relay 202300800071 1 24 Partition board 201290590122 1
10.4 Motor capacitor 202401100505 1 25 cover 201290590129 1
10.5 Transformer 202300900109 1 26 Temperature sensor 202301300303 2
10.6 Compressor capacitor 202401090057 1 27 Temp.sensor ass'y 202301300437 1
Discharge temp sensor
10.7 Contactor 202300850043 1 28 202301300130 1
ass'y
10.8 Wire joint 202301450130 1 29 room temp sensor ass'y 202301300197 1
10.9 Wire joint 202301450115 1 30 Compressor electric heater 202495030150 1
10.1 Wire clamp 201219900001 2 31 Rear net frame 201245500029 1
10.11 Wire joint 201135000004 2 32 Target Flow Switch 202301800829 1
Compressor wire joint
11 Handle 201148700005 2 33 202490590040 1
ass'y

30
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

MODEL: LRSJ-120/NYN1

31
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

No. Part Name Quantity BOM code No. Part Name Quantity BOM code
1 Rear net 1 201147090001 12.9 Wire joint 1 202301450115
2 Side board 1 201290590076 12.1 Wire clamp 2 201219900001
3 Target switch 1 202301800834 12.11 Wire joint 2 201135000004
4 main capilary 1 201690590234 13 Handle 2 201148700005
5 titanium heat exchanger 1 201790590010 14 Wire controller 1 203355100539
6 High pressure meter 1 201800100017 15 Front side board 1 201290590078
7 right side board 1 201290590080 16 Front panel 1 201275390172
8 Base ass'y 1 201290590118 17 Grille 1 201148350005
9 Solenoid 1 201600600045 18 Axial flow fan 1 201100300202
10 4-way valve assembly 1 201690590223 19 Motor 1 202400400148
10.1 Pressure controller 1 202301820042 20 Condenser ass'y 1 201590590014
10.2 4-way valve 1 201600600119 20.1 Flute shape pipe ass'y 1 201690590240
10.3 Accumulator tank 1 201601000004 21 Left bracket 1 201248400027
11 Compressor 1 201400620150 22 Rear supporter 1 201245320912
12 electrical controlling box 1 203390590057 23 Motor bracket ass'y 1 201248200038
12.1 Main controller board ass'y 1 201390590016 24 Cover 1 201290590119
Middle connection board
12.2 1 201390500120 25 Partition board ass'y 1 201275390176
ass'y
12.3 Relay 1 202300800071 26 Temperature sensor 2 202301300303
12.4 Motor capacitor 1 202401100505 27 Temp.sensor ass'y 1 202301300437
Discharge temp sensor
12.5 Transformer 1 202300900109 28 1 202301300130
ass'y
12.6 Compressor capacitor 1 202401090057 29 room temp sensor ass'y 1 202301300197
Compressor electric
12.7 Contactor 1 202300850043 30 1 202403100321
heater
12.8 Wire joint 1 202301450130

32
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

MODEL: LRSJ-140/NYN1

33
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

No. Part Name Quantity Quantity No. Part Name Quantity Quantity
1 Rear net 201147090001 1 12.9 Wire joint 202301450115 1
2 Side board 201290590076 1 12.1 Wire clamp 201219900001 2
3 Target switch 202301800834 1 12.11 Wire joint 201135000004 2
4 Main capillary ass'y 201690590243 1 13 Handle 201148700005 2
5 Titanium heat exchanger 201790590011 1 14 Wire controller 203355100539 1
6 High pressure meter 201800100017 1 15 Front side board 201290590078 1
7 right side board 201290590080 1 16 Front panel 201275390172 1
8 Base ass'y 201290590118 1 17 Grille 201148350005 1
9 Solenoid 201600600045 1 18 Axial flow fan 201100300202 1
10 4-way valve ass'y 201690590247 1 19 Motor 202400400148 1
10.1 Pressure controller 202301820042 1 20 Condenser ass'y 201590590014 1
10.2 4-way valve 201600600119 1 20.1 Flute shape pipe ass'y 201690590240 1
10.3 Accumulator tank 201601000004 1 21 Left bracket 201248400027 1
11 Compressor 201400630440 1 22 Rear supporter 201245320912 1
12 E-part box ass'y 203390590058 1 23 Motor bracket ass'y 201248200038 1
12.1 Main controller board 201390590016 1 24 Cover 201290590119 1
ass'y
12.2 Middle connection board 201390500120 1 25 Partition board ass'y 201275390176 1
ass'y
12.3 Relay 202300800071 1 26 Temperature sensor 202301300303 2
12.4 Motor capacitor 202401100505 1 27 Temp.sensor ass'y 202301300437 1
12.5 Transformer 202300900109 1 28 Discharge temp sensor 202301300130 1
ass'y
12.6 Compressor capacitor 202401000411 1 29 room temp sensor ass'y 202301300197 1
12.7 Contactor 202300850043 1 30 Compressor electric 202403100321 1
heater
12.8 Wire joint 202301450130 1

34
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

MODEL: LRSJ-450/SY

35
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

No. Part Name Quantity No. Part Name Quantity

1 Net 2 25.2 Cover ass'y 1

2 Right sealing plate D of condenser 1 25.3 PCB 1

3 Titanium heat exchanger 1 25.4 Wire joint 4

4 Right sealing plate A of condenser 1 25.5 Compressor capacitor 1

5 Input tube I of unit B 1 25.6 Terminal label 1

5.1 Electronic expansion valve 1 25.7 Wire joint 1

6 Input tube II of unit A 1 25.8 Wire joint, 3p 1

6.1 Strainer 1 25.9 Wire joint 1

7 Input tube I of unit A 1 25.10 Contactor 2

7.1 Electronic expansion valve 1 25.11 Relay 2

8 Left sealing plate A of condenser 1 25.12 Wire joint, 4p 1

9 Input tube ass'y of unit A 1 25.13 Axial flow fan 1

9.1 Pressure controller 1 25.14 Three-phase power protection devices 1

10 4-way valve ass'y of unit A 1 26 Compressor 1

10.1 4-way valve 1 27 Drainage pan holder 2

10.2 4-Ways valve solenoid 1 28 E-Part box cover 1

10.3 Muffler 1 29 Drainage pan holder 1

10.4 Strainer 1 30 Protecting water box 1

36
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

10.5 Pipe joint 3 31 Condenser ass'y of unit A 1

10.6 Pressure controller 1 32 Cover 1

11 Inputtub II of unit B 1 33 1

11.1 Strainer 1 34 Condenser ass'y of unit B 1

12 B unit 4-way valve ass'y 1 35 Motor holder 2

12.1 4-way valve 1 36 Side sealed board 4

12.2 4-Ways valve solenoid 1 37 Clapboard supporting board 3

12.3 Muffler 1 38 Motor bracket 1

12.4 Strainer 1 39 Cover 2

12.5 Pipe joint 3 40 Motor 1

13 Suction pipe ass'y A 1 41 Axial flow fan 1

13.1 Pipe joint 1 42 Top cover 1

14 Suction pipe ass'y D 1 43 Middle partition plate 1

14.1 Pipe joint 1 44 Top cover 1

15 Support board 2 45 Sealed board 1

16 Cover 1 46 Rear cover 1

17 Cover board 2 47 Front cover 1

18 Bracket ass'y 2 48 About clapboard 2

19 Bracket ass'y 2 49 EEV solenoid 2

20 Base ass'y 1 50 Discharge temp sensor 2

21 Accumulator cylinder 2 51 Compressor electric heater 2

22 Compressor 1 52 Room temp sensor ass'y 1

23 Base 1 53 Temp sensor ass'y 6

24 Base ass'y 1 54 Pressure controller 2

25 E-controlling box ass'y 1 55 Pressure controller 2

25.1 E-part boxr Ass'y 1 56 R22 7

57 Wire controller 1

37
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

MODEL: LRSJ-900/SY

38
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

No. Part Name BOM code Quantity No. Part Name BOM code Quantity
1 Axial flow fan 201200300013 2 28 Right cover 201290190082 1
2 Motor 202400400399 2 29 Mid upright support 201290100211 2
3 Motor bracket ass'y 201290100005 4 30 Pole 201290190074 4
Unit B fixed tray ass'y of
4 201290108629 1 31 Net 201290100240 2
condenser
5 Condenser ass'y of unit A 201590500621 1 32 Rear left cover ass'y 201290501318 1
6 Condenser ass'y of unit B 201590500622 1 33 Rear right cover ass'y 201290501310 1
7 Triangle reinforcement ass'y 201290100218 8 34 Mid horizontal support 201290100219 2
8 Drain pipe 201190100001 4 35 Condenser seal connector 201290108626 1
A combination of pieces of
9 4-way valve ass'y of unit A 201690502361 1 36 201290108627 1
fixed plate condenser
10 4-way valve ass'y of unit B 201690502356 1 37 Net 201290100237 4
Heat exchanger input tube of
11 201690502350 1 38 Condenser seal connector 201290108625 1
unit A
12 E-part box door 201290100194 1 39 Condenser side board 201290108624 2
13 Compressor 201401420300 2 40 Mid horizontal support 201290100223 2
14 Rubber gasket 202790150330 6 41 Top cover 201195300051 2
15 Pipe clamp B 201286900515 4 42 Top upright support 201290100191 2
16 Separator 201601100055 2 43 E-controlling box ass'y 203390500614 1
Heat exchanger input tube of
17 201690502344 1 43.1 E-part box 201290100212 1
unit B
Electric installation
18 Titanium heat exchanger 201790501177 1 43.2 201290190083 1
board ass'y
19 Conduit ass'y of unit B 201690502352 1 43.3 PCB 201390500623 1
Mounting panel ass'y of
20 201290501308 2 43.4 Wire joint, 3p 202301450044 2
compressor
21 Conduit ass'y of unit A 201690502354 1 43.5 Wire joint 202301450130 1
22 Base ass'y 201290501320 1 43.6 Wire joint 202301450110 1
23 Front right cover ass'y 201290501314 1 43.7 Wire joint 202301450122 3
24 Front left cover ass'y 201290501316 1 43.8 AC contactor 202300850050 2
25 Tube fixed panel A 201290501370 2 43.9 Transformer 202300900109 1
43.1
26 Tube fixed panel B 201290501371 3 Relay 202300800003 2
0
43.1
27 Reinforcement board 201290100247 4 Compressor capacitor 202401000410 2
1

39
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

8. PCB explain
A

■ A : appliance type dial code

40
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

Model: 45KW & 90KW

41
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

42
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

43
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

44
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

Part 3
Installation
1. Precautions .................................................................... 46

2. Installation information ................................................. 47

3. Unit Appearance ............................................................ 48

4. Accessories .................................................................... 50

5. Inspecting and Handling the Unit ................................. 50

6. Water pipeline diagram ................................................. 51

7. Water pump selection .................................................... 52

8. Tools required for installation ....................................... 52

9. Electric connection ........................................................ 52

45
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

1. Precautions
To prevent injury to the user or other people and property damage, the following instructions must be
followed. Incorrect operation due to ignoring of instructions may cause harm or damage.
The safety precautions listed here are divided into two categories. In either case, important safety
instructions are listed to which close attention must be paid.

WARNING
Failure to observe a warning may result in death.

CAUTION
Failure to observe a caution may result in injury or damage to the equipment.

WARNING
■ The water heating unit must be earthed effectively.
■ A creepage breaker must be installed near the power supply.
■ Ask your supplier for installation of the air source heat pump water heating units. Incomplete installation
performed by yourself may result in water leakage, electric shock, or fire.
■ Ask your supplier for the repair and maintenance. Incomplete repair and maintenance may result in
water leakage, electric shock or fire.
■ In order to avoid electric shock, fire or injury, if any abnormality is detected, such as smell of fire, turn off
the power supply and call your supplier for instructions.
■ Never replace a fuse with that of wrong rated current or other wires when a fuse blows out. Use of
wrong wire or copper wire may cause the unit to break down or a fire.
■ Do not insert fingers, rods or other objects into the air inlet or outlet. When the fan is rotating at high
speed, it will cause injury.
■ Never use a flammable spray such as hair spray, lacquer paint near the unit. It may cause a fire.
■ Never touch the air outlet or the horizontal blades while the swing flap is in operation. Fingers may
become caught or the unit may break down.
■ Never put any objects into the air inlet or outlet. Objects touching the fan of high speed can be
dangerous.
■ Do not dispose this product as unsorted municipal waste. Collection of such waste separately for
special treatment is necessary.
■ The appliance shall be installed in accordance with national wiring regulations.

CAUTION
■ Do not use the air-source water heater for other purposes.
■ Before cleaning, be sure to stop the operation and turn the breaker off or pull out the power cord.
Otherwise, an electric shock and injury may be caused.
■ In order to avoid injury, do not remove the fan guard on the outdoor unit.
■ Do not operate the air-source water heater with a wet hand. An electric shock may be caused.
■ In the place and the wall where water may be spattered, the installation height must be more than 1.8m.
■ At the water inlet, the One Way valve must be installed.
■ After a long use, check the unit stand and fittings. If damaged, the unit may fall and result in injury.
■ Never touch the internal parts of the controller.
■ Do not remove the front panel. Some parts inside are dangerous to touch, and a machine malfunction
may be caused.
■ Never expose babies, plants or animals directly to the air flow. Adverse influence to babies, animals and
plants may be resulted.

46
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

2. Installation information
■ Enough space is installation and maintenance shall be preserved.
■ The air inlet and outlet should be free from obstacles and strong wind.
■ The bearing surface should be flat, able to bear weight of the unit and suitable for installing the unit
horizontally without increasing noise or vibration.
■ The operation noise and air flow expelled shall not affect neighbors.
■ No flammable gas is leaked nearby.
■ It is convenient for piping and wiring.

■ The maximum pressure is 0.4 Mpa, when the pressure is more than 0.4 Mpa, Please add a pressure
relief valve.

CAUTION
■ Installing the equipment in any of the following places may lead to malfunction of the equipment (if it is
inevitable, consult the supplier):
1) The site contains mineral oils such as cutting lubricant.
2) Seaside where the air contains much salt.
3) Hot spring area where corrosive gases exist, e.g., sulfide gas.
4) Factories where the power voltage fluctuates seriously.
5) Inside a car or cabin.
6) Place like kitchen where oil permeates.
7) Place where strong electromagnetic waves exist.
8) Place where flammable gases or materials exist.
9) Place where acid or alkali gases evaporate.
10) Other special environments.
■ Precautions before installation
1) Decide the correct way of conveying the equipment.
2) Try to transport this equipment with the original package.
3) If the unit has to be installed on a metal part of the building, electric insulation must be installed, and the
installation must meet the relevant technical standards for electric devices.
■ Installation space
Before installing the unit, reserve the space of maintenance .

WARNING
■ Ask your supplier to install the air source heat pump water heating units. Incomplete installation
performed by yourself may result in a water leakage, electric shock, or fire.
■ The place without direct sunlight and other heat supplies. If there’s no way to avoid these, please install
a covering.
■ The unit must be securely fixed, or else, noise and shaking will be resulted.
■ Make sure that there’s no remora around the unit.
■ In the place where there is strong wind like seashore, fix the unit in the location protected from the wind.
■ Carry the unit onto the site
1) In order to avoid scratch or deformation of the unit surface, apply guard boards to the contacting
surface.
2) No contact of fingers and other things with the vanes.

47
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

3) Don’t incline the unit more than 45° in moving, and keep it vertical when installing.
■ Install the unit.
1) The circulating air for every unit should be more than 2400m3/h.
2) Make sure there is enough Installation space.
3) Outline dimensional drawing

Water treatment
In order to use our appliances under the best conditions, the following parameters must be respected:
free chlorine: max.2.5mg/l, total bromine: max. 5.5 mg/l, PH between 6.9 and 8.0. If chemical or
electrophysical disinfection systems are used, the installer and user must contact the supplier to ensure they
are compatible with our materials. These systems must be installed after the heating system.

3. Unit Appearance

48
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

49
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

4. Accessories
Check whether the following assemblies are complete.
Model: 6KW, 8KW, 12KW, 14KW
Name Quantity Note Purpose
Installation& Operation Manual 1 —— Installation and Operation instruction
Seal ring 1 —— Discharge condensate water
Water outlet jointing pipe 1 —— Discharge condensate water

Model: 45KW, 90KW

5. Inspecting and Handling the Unit


After delivery, the package should be checked and any damage should be reported immediately to the
carrier claims agent.
When handling the unit, take into account the following:

1. Fragile, handle the unit with care.

Keep the unit upright in order to avoid compressor damage.


2. Choose before hand the path along which the unit is to be brought in.
3. Move this unit with original package.
4. When lifting the unit , always use protectors to prevent belt damage and pay attention to the balance of
the unit’s gravity.

50
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

6. Water pipeline diagram

Connect drawing for pipeline system (45KW & 90KW)


51
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

8.1 Connection is established with a by-pass on the pool filtration circuit after the filter and before the water
treatment device (see diagrams upper). In order to connect other heat source
8.2 During installation of connective pipe, you must beware not to let any dust or other foreign substance
intrude into pipe system.
8.3 Water inlet and outlet pipes can be installed as long as the water-heating A/C have been fixed.
8.4 Thermal insulation materials should be employed to seal up water outlet and inlet pipes.
8.5 Before operation, please confirm that the specifications of connective pipes are correct, and thermal
insulation layer have been wrapped on pipes. It requires that all pipes have been sealed up, and no water
leakage has been detected.
8.6 Hydraulic circuit test pressure: 3 bars - Hydraulic circuit operating pressure: 1.5 bar
pressure drop 2.2 mCE (0.22 bar)

7. Water pump selection

Model Water flow Recommendatory flow


LRSJ-60/NYN1 0.8~20m3/h 3m3/h
LRSJ-80/NYN1 0.8~20m3/h 4m3/h
LRSJ-120/NYN1 1.5~20m3/h 5m3/h
LRSJ-140/NYN1 1.5~20m3/h 5.8m3/h
LRSJ-450/SY 9-30 15 m3/h
LRSJ-900/SY 18-50 30 m3/h

8. Tools required for installation


- 1 set of flat head screwdrivers
- 1 set of crosshead screwdrivers
- 1 cutter
- 1 wire stripper
- 1 pipe or round head spanner 13
- 1 ratchet spanner
- 1 pliers
- 2 straps (for handling)

9. Electric connection
9.1 Power specification
2
Diameter of the thinnest cable (mm ) Manual Switch
Item (Metal pipe and synthetic resin pipe wiring) (A)
Power Supply
Model Size (continuous length
Earthling Wire Capacity Fuse
<30 m
LRSJ-60/NYN1 220~240V-1ph-50Hz 2.5 2.5 ≥30 20
LRSJ-80/NYN1 220~240V-1ph-50Hz 2.5 2.5 ≥30 20
LRSJ-120/NYN1 220~240V-1ph-50Hz 4.0 4.0 ≥30 25
LRSJ-140/NYN1 220~240V-1ph-50Hz 4.0 4.0 ≥30 25
LRSJ-450/SY 380~420V-3ph-50Hz 6 6 ≥60 50
LRSJ-900/SY 380~420V-3ph-50Hz 16 16 ≥125 100

9.2 Electric wiring diagram


Electric wiring diagram for Model 6kW 8kW 12kW 14kW

52
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

Electric wiring diagram for single model of 45kW or 90kW

Networking communication schematic of main unit and auxiliary unit (45KW & 90KW)

53
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

Part 4
Trial Operation
1. Confirmation Before the Trial Operation ...................... 55

2. Operating Instruction .................................................... 55

2.1 Operating Instruction for 6KW,8KW,12KW,14KW ..... 55

2.2 Operating Instruction for 45KW,90KW ....................... 58

54
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

1. Confirmation Before the Trial Operation


1.1 All the installation is complete.
1.2 Water heater is installed correctly.
1.3 The pipelines and wiring are correct.
1.4 The accessories are installed correctly.
1.5 The drainage is smooth.
1.6 The thermal insulation is sound.
1.7 The earthing wire is connected correctly.
1.8 The power voltage is consistent with the rated voltage of the heater.
1.9 No obstacle at the air inlet and outlet of the unit.
1.10 The leakage protector can work effectively.

2. Operating Instruction
2.1 Operating Instruction for 6KW,8KW,12KW,14KW

2.1.1 The appearance of controller

2.1.2 Name and function description of LCD screen of wire controller

55
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

2.1.3 Names of keys on the wire controller and the keypad operation description

2.1.4 Application of wire controller


 Preparation before running the unit.
When you run the unit for the first time, all the indicators on the wire controller will light for 3s, and then,
display the fiducial web page. After no operation for 40s, all indicators will go out automatically except POOL
TEMP indicator lighting. When the unit is running, if there is no operation or malfunction for 10s, the
backlight of the display will go out automatically. After 30s ,all indicator will disappear except operation mode
and pool temp.
By default, the unit operates Heat Mode. Change:
 Mode Selection
The unit is enhanced with three operation modes, Cool Mode, Heat Mode and Pump Mode.
Cool Mode: The unit cools down swimming pool water by compressor drive according to heat-pump
principle. Used when the swimming temp. is high in summer.
Heat Mode: The unit heats swimming pool water by compressor drive according to heat-pump principle.
Used when the ambient temp. is low.
Pump Mode: The pump run for circling the water. Used when trial run or other necessary situation.

By default, the unit operates Heat Mode. Change:

56
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

 Temperature set
Temp. displayed is the setting
water temp. Default is 28℃ and the Cool mode setting range is
10~30℃,the heat mode setting range is 20~35℃

 Power on/Power off


Press Power On/Power Off button after all the above have finished
and the system will run as the setting. And simply press the same
button to stop it.

 Operation status display

2.1.5. Fault code list


Display Malfunction Description
E1 Phase sequence of power error
E2 Outdoor unit and wire controller communication error
E3 Outlet water temperature sensor error
E4 Inlet water temperature sensor error
E5 Evaporator pipe temperature sensor error
E7 Ambient temperature sensor error
E9 Water flow switch error
EE Discharge pipe temperature sensor error
P0 Discharge pressure over-high protection
P1 Inhale pressure over-low protection
P4 Compressor current over-high protection
P6 Evaporator temperature over-high protection
Pb Anti-frozen protection
PF Discharge pipe temperature over-high protection

57
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

2.1.6. Self-checking function

NO. Description
1 Normal display : T6 ;
2 Mode code :(0 6KW; 1 8KW; 2 12KW; 3 14KW);
3 Operate mode:(1 cooling;16 water heating;4 pump );
4 Fan speed(0 stop;1 low ;2 high);
5 T4;
6 Tp;
7 T3;
8 T6;
9 Tout;
10 Compressor current ;
11 Ts;
12 The last error code“--”

2.2 Operating Instruction for 45KW,90KW

2.2.1 The appearance of controller

58
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

2.2.2 operating instructions of buttons

59
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

2.2.3 ON/OFF

60
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

2.2.4 Trouble shooting

61
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

2.2.5 Maintaince and upkeep

62
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

2.2.6 Error code


63
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

NO. Code Reason


1 E0 Water flow detection error or fan protection (the 3rd time)
2 E1 Power phase sequence error
3 E2 Communication error
4 E3 Total water outlet temperature sensor error
5 E4 Outlet water temperature sensor of system A error
6 E5 Pipe temperature sensor in condenser A error
7 E6 Pipe temperature sensor in condenser B error
8 E7 Outdoor ambient temperature sensor error or power supply protection
9 E8 Outlet water temperature sensor of system B error
10 E9 Water flow detection error or fan protection (the 1st and 2nd time)
11 EA Main unit detect that auxiliary unit's quantity have decreased
12 Eb Freeze-proof temperature sensor of system A error
13 EC Wire controller did not found out any on-line module unit
14 Ed 1-hour consecutive 3-times PE protection
15 EF freeze-proof temperature sensor of system B error
16 P0 High pressure or air discharge temperature protection error in system A
17 P1 Low pressure protection system A
18 P2 High pressure or air discharge temperature protection error in system B
19 P3 Low pressure protection system B
20 P4 Current protection in system A
21 P5 Current protection in system B
22 P6 Condenser high pressure protection in system A
23 P7 Condenser high pressure protection in system B
24 PA Low ambient temperature drive-up protection
25 Pb System freeze-proof protection
26 PC Reserved
27 PE Low-temperature protection of system
28 F1 wire controller failure
Failure of reduction of wired controller number at parallel connection of
29 F2
multiple wired controller (reserved)

2.2.7 Self-checking function

64
Midea HVAC-TSM-2010-03 Midea Swimming Pool Type Heat Pump Water Heater Technical Manual

NO. Description
1 Normal display : T6 ;
2 Operate mode:(1 cooling;2 heating; 4 pump ;8 standby)
3 Capacity of compressor B
4 Quantity of online units
5 Ambient temperature
6 Pipe temperature of condenser A
7 Pipe temperature of condenser B
8 water temperature of the pool T5
9 water outlet temperature of unit A
10 water outlet temperature of unit B
11 Aperture of E-expansion valve A
12 Aperture of E-expansion valve B
13 Compressor current for system A
14 Compressor current for system B
15 Error code for the last time

65