P 106 Roof Floor Plan Water Supply

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

----- 7.

3M ROAD -----
E-3
PLOT LIMIT PLOT LIMIT

SET BACK LINE

SET BACK LINE

SET BACK LINE

SET BACK LINE


VILLA NO - 01

DRAINAGE - LEGEND

-----
PERGOLA PERGOLA PERGOLA PERGOLA
-----

MANHOLE 600 X 600


DRY MANHOLE 600 X 600
GULLY TRAP - GT

NEIGHBOUR PLOT AFEMQTHA1808


SLOPE 1:50 DUCT SLOPE 1:50 DUCT DUCT SLOPE 1:50 DUCT SLOPE 1:50
075X035 075X035 075X035 075X035
NEIGHBOUR PLOT AFECVTH017

DRY GULLY TRAP - DGT


SLOPE 1:50

SLOPE 1:50

SLOPE 1:50

SLOPE 1:50
SL

SL
0

0
1:5

1:5

O
PE

PE
FLOOR TRAP - FT
PE

PE

1:5

1:5
O

O
SL

SL

0
DRAINAGE SOIL PIPE
DRAINAGE WAIST PIPE
DRAINAGE VENT PIPE
CO CLEAN OUT
V.P VENT PIPE
T/B TO BELOW
VILLA NO - 02 F/A FROM ABOVE
GLASS GLASS GLASS GLASS WC WATER CLOSET

E-2
E-4

HEADROOM TOP LEVEL

HEADROOM TOP LEVEL

HEADROOM TOP LEVEL

HEADROOM TOP LEVEL


WB WASH BASIN
DN RIDGE LINE DN DN RIDGE LINE DN RIDGE LINE
RIDGE LINE
HD HEAVY DUTY
+9.55m LVL.

+9.55m LVL.

+9.55m LVL.

+9.55m LVL.
D MH DRY MAINHOLE
045 X 150

045 X 150

045 X 150

045 X 150
DUCT

DUCT

DUCT

DUCT
VENT PIPE VENT PIPE VENT PIPE VENT PIPE

SOLAR SYSTEM SOLAR SYSTEM SOLAR SYSTEM SOLAR SYSTEM

CUTOUT CUTOUT CUTOUT CUTOUT


070 X 030 070 X 030 070 X 030 070 X 030

1000 GALS POLYGON O/H 1000 GALS POLYGON O/H 1000 GALS POLYGON O/H 1000 GALS POLYGON O/H
TANK ON CONCRETE TANK ON CONCRETE TANK ON CONCRETE TANK ON CONCRETE
UPSTANDS CONN. TO UPSTANDS CONN. TO UPSTANDS CONN. TO UPSTANDS CONN. TO 1. THIS DRAWING IS THE PROPERTY OF AL GAFRY CONSULTING,
1HP BOOSTER PUMP
& COVERED IN PAINTED TERRACE 1HP BOOSTER PUMP
& COVERED IN PAINTED TERRACE TERRACE 1HP BOOSTER PUMP
& COVERED IN PAINTED TERRACE 1HP BOOSTER PUMP
& COVERED IN PAINTED ITS COPYRIGHT IS RESERVED WIYH THEM.IT MUST NOT BE RETAINED,
SLOPE 1:50

SLOPE 1:50

SLOPE 1:50

SLOPE 1:50
SLATTED TIMBER ENCL. SLATTED TIMBER ENCL. SLATTED TIMBER ENCL. SLATTED TIMBER ENCL.
COPIED OR REPRODUCED IN ANY FORM WITHOUT THE WRITTEN
+7.65m LVL. +7.65m LVL. +7.65m LVL. +7.65m LVL.

SL

SL
0

CONSENT OF AL GAFRY CONSULTING


1:5

1:5

OP

OP
-----

E
2. ALL DIMENSIONS ARE IN MILLIMETER
OP

OP

1:5

1:5
SL

SL

OTHERWISE.DO NOT SCALING DRAWING,ONLY WRITTEN DIMENSIONS

-----
SLOPE 1:50 SLOPE 1:50 SLOPE 1:50 SLOPE 1:50 ARE APPROXIMATE.

3. ALL DIMENSIONS TO BE VERIFIED BY THE CONTRACTOR AND


DISCREPENCIES,IF ANY REPORTED TO THE CONSULTANT BEFORE
COMMENCING ANY WORK ON SITE
4. THIS DRAWING SHOULD BE READ IN CONJUCTION WITH RELEVANT
ARCHITECTURAL,STRUCTURAL AND SERVUCES DRAWINGS.

PERGOLA PERGOLA PERGOLA PERGOLA

GARAGE ROOF GARAGE ROOF GARAGE ROOF GARAGE ROOF


+3.00m LVL. PERGOLA +3.00m LVL. PERGOLA PERGOLA +3.00m LVL. PERGOLA +3.00m LVL.

VILLA NO - 03
SET BACK LINE

SET BACK LINE


CONSULTANT:
PERGOLA PERGOLA PERGOLA PERGOLA

PLOT LIMIT PLOT LIMIT


CLIENT :
E-1

----- 7.3M ROAD ----- PROJECT TITLE:

PLOT: LOCATION:

(SCALE : - 1:100) AFECVTH016 JABEL ALI FIRST 591

SCALE DRW. BY CKD.BY

1:100 SHAHID SHIVA


DATE PROJ. NO:
AUG-2016 P-397

TITLE :
VILLA NO - 04 P 106
ROOF FLOOR PLAN
WATER SUPPLY