Quad-band Panel R1 R2 Y1 Y2

Frequency Range 698–862 880–960 1695–2690 1695–2690


Dual Polarization X X X X
HPBW 65° 65° 65° 65°
Adjust. Electr. DT 2°–12° 2°–12° 2.5°–12° 2.5°–12°
set by

4XPol Panel 698–862/880–960/1695–2690/1695–2690 65°/65°/65°/65° 15.5/16/18/18dBi


2°–12°/2°–12°/2.5°–12°/2.5°–12°T
Type No. 80010868
Low bands R1, connector 1– 2 R2, connector 3 – 4
698– 862 880 – 960
Frequency Range (MHz) 698 – 806 790 – 862 880 – 960
Gain at mid Tilt (dBi) 15.0 15.3 15.9
Gain over all Tilts (dBi) 14.9 ± 0.5 15.2 ± 0.4 15.8 ± 0.3
Horizontal Pattern:
Azimuth Beamwidth (°) 71 ± 2.5 68 ± 2.4 66 ± 1.6
Front-to-Back Ratio,
> 22 > 24 > 26
Total Power, ± 30° (dB)
Cross Polar Discrimination
> 22 > 22 > 19
at Boresight (dB)
Cross Polar Discrimination
>7 >7 > 8.5
over Sector (dB)
Azimuth Beam
<2 < 2.5 < 2.5
Port-to-Port Tracking (dB)
Vertical Pattern:
Elevation Beamwidth (°) 11.0 ± 0.9 10.3 ± 0.5 9.4 ± 0.5
Electrical Downtilt
2 – 12 2 – 12
continuously adjustable (°)
Tilt Accuracy (°) < 0.5 < 0.4 < 0.3
First Upper Side Lobe
> 16 > 18 > 18
Suppression (dB)
Upper Side Lobe
Suppression, 20° Sector > 16 > 18 > 18
above Main Beam (dB)
Cross Polar Isolation > 30 dB > 30 dB
Port to Port Isolation > 28 dB (R1//R2)
> 30 dB (R1//Y1,Y2)
> 30 dB (R2//Y1,Y2)
Max. Effective Power per Port 250 W (at 50 °C ambient temperature)
Values based on ngmn-P-BASTA requirements.
936.4365/a ngmn 04.18.04 Subject to alteration.

www.kathrein.de 80010868 Page 1 of 4


KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820
Quad-band Panel

Left side, high band Y1, connector 5 – 6


1695 – 2690
Frequency Range (MHz) 1695 – 1880 1850 – 1990 1920 – 2170 2300 – 2400 2500 – 2690
Gain at mid Tilt (dBi) 17.4 17.8 17.9 17.6 18.3
Gain over all Tilts (dBi) 17.3 ± 0.5 17.7 ± 0.3 17.8 ± 0.3 17.5 ± 0.4 18.1 ± 0.6
Horizontal Pattern:
Azimuth Beamwidth (°) 64 ± 4.2 61 ± 3.0 60 ± 2.5 65 ± 5.0 61 ± 5.6
Front-to-Back Ratio,
> 26 > 26 > 26 > 24 > 24
Total Power, ± 30° (dB)
Cross Polar Discrimination
> 16 > 21 > 25 > 18 > 15
at Boresight (dB)
Cross Polar Discrimination
>8 >8 > 9.5 >9 > 10
over Sector (dB)
Azimuth Beam
<2 <2 < 1.5 < 1.5 <2
Port-to-Port Tracking (dB)
Vertical Pattern:
Elevation Beamwidth (°) 6.3 ± 0.4 5.9 ± 0.2 5.6 ± 0.4 4.9 ± 0.2 4.4 ± 0.3
Electrical Downtilt
2.5 – 12
continuously adjustable (°)
Tilt Accuracy (°) < 0.2 < 0.2 < 0.2 < 0.2 < 0.2
First Upper Side Lobe
> 19 > 19 > 18 > 17 > 18
Suppression (dB)
Upper Side Lobe
Suppression, 20° Sector > 15 > 15 > 14 > 14 > 15
above Main Beam (dB)
Cross Polar Isolation > 28 dB
Port to Port Isolation > 30 dB (R1,R2//Y1)
> 30 dB (Y1//Y2)
Max. Effective Power per Port 200 W (at 50 °C ambient temperature)
Values based on ngmn-P-BASTA requirements.

Right side, high band Y2, connector 7– 8


1695 – 2690
Frequency Range (MHz) 1695 – 1880 1850 – 1990 1920 – 2170 2300 – 2400 2500 – 2690
Gain at mid Tilt (dBi) 17.3 17.7 18.0 18.4 18.4
Gain over all Tilts (dBi) 17.3 ± 0.4 17.6 ± 0.3 17.9 ± 0.4 18.3 ± 0.3 18.3 ± 0.4
Horizontal Pattern:
Azimuth Beamwidth (°) 64 ± 2.4 63 ± 3.2 62 ± 2.9 60 ± 2.0 60 ± 2.7
Front-to-Back Ratio,
> 24 > 23 > 24 > 23 > 25
Total Power, ± 30° (dB)
Cross Polar Discrimination
> 22 > 24 > 23 > 20 > 19
at Boresight (dB)
936.4365/a ngmn 04.18.04 Subject to alteration.

Cross Polar Discrimination


> 15.5 > 14.5 > 13 > 7.5 >9
over Sector (dB)
Azimuth Beam
<1 <1 <1 <2 <2
Port-to-Port Tracking (dB)
Vertical Pattern:
Elevation Beamwidth (°) 7.1 ± 0.4 6.7 ± 0.3 6.4 ± 0.4 5.5 ± 0.4 5.0 ± 0.2
Electrical Downtilt
2.5 – 12
continuously adjustable (°)
Tilt Accuracy (°) < 0.2 < 0.2 < 0.2 < 0.2 < 0.2
First Upper Side Lobe
> 20 > 21 > 22 > 17 > 20
Suppression (dB)
Upper Side Lobe
Suppression, 20° Sector > 13 > 16 > 15 > 15 > 16
above Main Beam (dB)
Cross Polar Isolation > 28 dB
Port to Port Isolation > 30 dB (R1,R2//Y2)
> 30 dB (Y1//Y2)
Max. Effective Power per Port 200 W (at 50 °C ambient temperature)
Values based on ngmn-P-BASTA requirements.

Page 2 of 4 80010868 www.kathrein.de


KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820
Quad-band Panel

Electrical specifications, all systems Mechanical specifications


Impedance (Ω) 50 Input 8 x 7-16 female long neck
VSWR < 1.5 Connector Position bottom
Return Loss (dB) > 14 Adjustment Mechanism FlexRET,
Interband Isolation (dB) > 28 continuously adjustable
Passive Intermodulation (dBc) < –150 (2 x 43 dBm carrier) Wind load (N) Maximum 1210
(at Rated Wind Speed: Frontal 1160
Polarization (°) +45, –45 150 km/h) Lateral 390
Values based on ngmn-P-BASTA requirements. Rearside 1210
Max. Wind Velocity (km/h) 241
Height / Width / Depth (mm) 1921 / 377 / 169
Category of
H (Heavy)
Mounting Hardware
Weight (kg) 35.0 / 37.0 (clamps incl.)
Packing Size (mm) 2121 / 397 / 212
Scope of Supply Panel, FlexRET and
2 units of clamps
for 42 – 115 mm diameter

Accessories (order separately if required) 72

13
’9
Weight Units per
Type No. Description Remarks
approx. antenna

85010002 1 clamp Mast: 110 – 220 mm diameter 2.7 kg 2


85010003 1 clamp Mast: 210 – 380 mm diameter 4.8 kg 2
85010008 1 downtilt kit Downtilt angle: 0° – 11° 6.5 kg 1

Accessories (included in the scope of supply)


738546 1 clamp Mast: 42 – 115 mm diameter 1.1 kg 2
86010153 FlexRET 1
936.4365/a ngmn 04.18.04 Subject to alteration.

For downtilt mounting use the clamps for an appropriate mast diameter together with the downtilt kit.
Wall mounting: No additional mounting kit needed.
1921
1948
1988

Material: Reflector screen: Aluminum.


Fiberglass housing: It covers totally the internal antenna components.
The special design reduces the sealing areas to a minimum and
guarantees the best weather protection. Fiberglass material guarantees
optimum performance with regards to stability, stiffness, UV resistance
and painting. The color of the radome is light grey.
All nuts and bolts: Stainless steel or hot-dip galvanized steel.

Grounding: The metal parts of the antenna including the mounting kit and the inner
conductors are DC grounded.

www.kathrein.de 80010868 Page 3 of 4


KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820
Quad-band Panel

Layout of interface:

Left Right

R2 R2
169*
195*

1695
4 3

Y1 Y1 R1 R1 Y2 Y2

104
6 5 2 1 8 7

54
124

224.5

325

377*

Bottom view
* Dimensions refer to radome

Correlation Table
R2
Frequency range Array Connector
936.4365/a ngmn 04.18.04 Subject to alteration.

698 – 862 MHz R1 1–2


880 – 960 MHz R2 3–4
1695 – 2690 MHz Y1 5–6 1x
1695 – 2690 MHz Y2 7–8

Y1 Y2
R1
Left Right

Page 4 of 4 80010868 Any previous data sheet issues have now become invalid.
www.kathrein.de
KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820