DTC P0778 Pressure Control Solenoid "B" Electrical (Shift Solenoid Valve SL2)

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

U151E AUTOMATIC TRANSAXLE – AUTOMATIC TRANSAXLE SYSTEM AX–97

Pressure Control Solenoid "B" Electrical (Shift


DTC P0778
Solenoid Valve SL2)
DESCRIPTION
Shifting from 1st to 5th is performed in combination with the ON and OFF operation of the shift solenoid
valves SL1, SL2, SL3, S4 and SR, which are controlled by the ECM. If an open or short circuit occurs in
any of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valves to allow the
vehicle to be operated safely (see page AX-35).
DTC No. DTC Detection Condition Trouble Area
P0778 ECM checks for an open or short circuit in • Open or short in shift solenoid valve SL2
shift solenoid valves SL2 (1 trip detection circuit
logic) • Shift solenoid valve SL2
Hybrid IC for solenoid indicates fail • ECM

MONITOR DESCRIPTION
The ECM commands gear shifts by turning the shift solenoid valves ON/OFF. When there is an open or
short circuit in any shift solenoid valve circuit, the ECM detects the problem and illuminates the MIL and
stores the DTC. And the ECM performs the fail-safe function and turns the other normal shift solenoid
valves ON/OFF. In case of an open or short circuit, the ECM stops sending current to the circuit (see page
AX-35).

MONITOR STRATEGY
Related DTCs P0778: Shift solenoid valve SL2/Range check
Required sensors/Components Shift solenoid valve SL2
Frequency of operation Continuous
Duration 1 sec.
MIL operation Immediate
Sequence of operation None

TYPICAL ENABLING CONDITIONS


The monitor will run whenever this DTC is not present. None
Battery voltage 11 V or more
Starter OFF
Ignition switch ON
Solenoid current cut status Not cut
CPU commanded duty 19% or more

TYPICAL MALFUNCTION THRESHOLDS


Solenoid status from MIC Fail

COMPONENT OPERATING RANGE


Output signal duty Less than 100%

AX
AX–98 U151E AUTOMATIC TRANSAXLE – AUTOMATIC TRANSAXLE SYSTEM

WIRING DIAGRAM

Shift Solenoid Valve SL2


(ECT Solenoid Valve)
ECM

SL2+
SL2+

SL2-
SL2-

C119177E04

INSPECTION PROCEDURE

1 INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL2)

(a) Disconnect the B32 wire connector.


Wire Harness Side (b) Measure the resistance of the transmission wire.
Standard resistance
Tester Connection Condition Specified Condition
SL2+ 5 (SL2+) - 12 (SL2-) 20°C (68°F) 5.0 to 5.6 Ω
5 (SL2+) - Body ground 20°C (68°F) 1 MΩ or higher
12 (SL2-) - Body ground 20°C (68°F) 1 MΩ or higher
6 5 4 3 2 1
13 12 11 10 9 8 7
NG Go to step 3

SL2-

C136383E04

OK

AX
U151E AUTOMATIC TRANSAXLE – AUTOMATIC TRANSAXLE SYSTEM AX–99

2 CHECK WIRE HARNESS (TRANSMISSION WIRE - ECM)

(a) Disconnect the B30 ECM connector.


Wire Harness Side (b) Measure the resistance of the wire harness side
connector.
Standard resistance
B30
SL2+ SL2- Tester Connection Condition Specified Condition
B30-12 (SL2+) - B30-13 20°C (68°F) 5.0 to 5.6 Ω
(SL2-)
B30-12 (SL2+) - Body 20°C (68°F) 1 MΩ or higher
ground
B30-13 (SL2-) - Body 20°C (68°F) 1 MΩ or higher
ground

NG REPAIR OR REPLACE HARNESS AND


CONNECTOR
A107892E72

OK

REPLACE ECM

3 INSPECT SHIFT SOLENOID VALVE SL2

(a) Remove the shift solenoid valve SL2.


(b) Measure the resistance of the solenoid valve.
1 2 Standard resistance:
5.0 to 5.6 Ω at 20°C (68°F)
(c) Connect the battery's positive (+) lead with a 21 W bulb
to terminal 2 and the negative (-) lead to terminal 1 of the
solenoid valve connector. Then check that the valve
moves and makes an operating noise.
OK:
Valve moves and makes operating noise.
NG REPLACE SHIFT SOLENOID VALVE SL2
1 2

(-) (+)

C140848E01

OK
AX
REPAIR OR REPLACE TRANSMISSION WIRE

You might also like