Minimum Plumbing Facilities
Minimum Plumbing Facilities
Minimum Plumbing Facilities
BATHTUBS
URINALS or
WATER CLOSETS LAVATORIES DRINKING
TYPES OF OCCUPANCY (Fixtures per SHOWERS FOUNTAINS
(Fixtures per Person) (Fixtures per Person)
Person) (Fixtures per
Person)
Male Female Male Female
1: 1-15 1: 1-15 0: 1-9
2: 16-53 2: 16-53 1: 10-50
Assembly Places – Theaters,
3: 36-55 3: 36-55
Auditoriums, Convention Halls,
Over 55, add 1 Over 55, add 1 Add 1 fixture 1 per 40 1 per 40
etc., - for Permanent Employee
fixture for each fixture for for each
Use
additional 40 each additional additional 50
persons 40 persons males
3: 1-50 1: 1-100
1: 1-100 4: 51-100 2: 101-200 1: 1-200 1: 1-200
2: 101-200 8:101-200 3: 201-400 2: 201-400 2: 201-400
Assembly Places – Theaters, 3: 201-400 11: 201-400 4: 401-600 3: 401-750 3: 401-750
Auditoriums, Convention Halls, Over 400, add 1 Over 400, add Over 600, add Over 750, add Over 750, add 1 per 75
etc., - for Public Use fixture for each 2 fixtures for 1 fixture for 1 fixture for 1 fixture for
additional 500 each additional each each additional each additional
persons 300 persons additional 500 500 persons 500 persons
males
1 per 25
1 per 12 1 per 12
1 per 10 1 per 8 Over 150, add
Over 150, add Over 150,
Dormitories Add 1 fixture Add 1 fixture 1 fixture for
1 fixture for add 1 fixture 1 per 8
School or Labor for each for each each
each additional for each
additional 25 additional 20 additional 50
20 additional 15
males
Dormitories 1: 1-15 1: 1-15 1 per 50 1 per 40 1 per 40 1 per 8
Staff Use 2: 16-35 2: 16-35
3: 36-55 3: 36-55
Over 55, add 1 Over 55, add 1
fixture for each fixture for
additional 40 each additional
Hospital Waiting Rooms 1 per room 1 per room 0: 1-9 1 per room 1 per room 1 per 75
Whenever urinals are provided, one water closet is subtracted from the number specified on the table, except that the number of water closets in such cases shall not be reduced to less than 2/3 of the minimum
specified.