PowerScale
10–50 kVA
Maximize your availability
with PowerScale
PowerScale – premium power protection
PowerScale is a mid-size, three-phase UPS system and space for internal batteries. PowerScale is a complete
that delivers premium power protection for the increasing power protection system in one box and allows for
loads in today’s server rooms and data centers. simple installation.
PowerScale is available in seven power ratings:
10, 15, 20, 25, 30, 40 and 50 kVA. The standalone three-phase UPS system is the ideal
solution for server rooms, networks, small data centers,
This new generation of transformer-less UPS responds to all telecommunications and health care infrastructures, banking
major concerns of IT and facility managers. As saving costs and industrial applications.
and 100 percent uptime are their top priorities, PowerScale
offers the lowest cost of ownership of any UPS system The broad range of PowerScale has been designed to offer
by providing energy efficiency, scalable flexibility, highest the most important benefits to our customers and fulfil today’s
availability and easy serviceability. most demanding requirements in terms of:
PowerScale
PowerScale
PowerScale
efficiency curve is typical for all ABB products, and hence the 95
This enables significant energy savings in every working Input power factor versus load
condition.The input power factor of PowerScale is near
unity. This is made possible by the advanced booster PFC 1.0
(Power Factor Correction) circuit of ABB’s transformer-less
technology. As a result there is no need for a filter for phase
compensation. When using PowerScale, the UPS system
respects the power grid regulations, and therefore achieves
important energy savings. 0.8
The outstanding low input current total harmonic distortion Input current total harmonie distortion (THDi)
(THDi) helps to enhance the compatibility with generators.
Low THDi eliminates possible interference with other 6
equipment in the scheme, reduces the size of power cables, 5
fuses and breakers at the input and avoids excess heating of 4
power transformers. 3
2
1
0
25% 50% 75% 100% load
Technical specifications
Flexible battery configuration With the advanced booster technology of ABB’s transformer-
In each cabinet, the space available for internal batteries less UPS, the number of battery blocks per string can be
is designed to fulfil most of the run-time requirements. The adjusted to the exact run-time required. This unique flexibility
smaller units (10 to 25 kVA) are available in two cabinet sizes, allows an optimal sizing of the battery capacity and a minimal
and the larger units (30 to 50 kVA) can house different battery investment.
sizes (7 / 9 Ah or 28 Ah).
Standard features
– – RS 232 on Sub-D9 port
–– 4 input contacts
–– 12 VDC source
–– RJ 45 for multidrop
Optional features
– – SNMP card (slot)
–– Card including 5 potential free output contacts
and USB port The front panel of the type C cabinet is easily removable.