SIEMENS
OEM
Outside Sensors QAC..
Type summary
‘+ Outside sensor for acquiring the outdoor temperature and - to a lesser extent
= solar radiation, wind influence and the temperature of the wall
‘+ The QAC.. and this Data Sheet are intended for OEMs which use the outside
sensors in connection with their products
‘+ Reference sensor for weather-compensated flow temperature control
‘* Measuring sensor for optimization functions
Type [Sensing element
[Measure- |Tole- Time |Weight |Packing size [Copper cable |Perm. cabie|
reference Iment range ance "constant dia. length
lQac2t® [LG-Ni 10002 at 0°C}-50..70°C + 0.4K |14:min [48 pieces [0.6mm — [20m
ind-vidually {5.5 mm
lQAcs1/101 NTC 575 0 at 20°C |-50..60°C [k1K [12min Jpacked in [4 mma [80 m’
73.9 |mutipacks —\6.6 rom
[QAC34/101 [NTC1000 0 at 25°C |50..70°C Je 1K [12min 1.5mm [120m
72mm
Ordering
CE101811en
2015-01-28,
‘QACRT at 0°C, GACSTIIOT and GACSAOT at=10..420°
® QAG2t is not supplied any more
When ordering, please give type reference according to “Type summary’, €9.
@ac3t/101
Building TechnologiesTechnical design
acai
@acst/i01
Qacsa/101
Mechanical design
‘The sensing element is a thin-film LG-Ni element with a resistance of 1000 2 at 0 °C.
‘The resistance rises as a function of the temperature at about 5 2 per Kelvin.
‘The sensing element is an NTC resistor with a linearized characteristic and a
resistance of 575.2 at 20 °C.
The sensing element is an NTC resistor with a resistance of 1000 0 at
25°C. The resistance drops at about 4 % per Kelvin,
Mounting and installation
‘The outside sensor consists of plastic housing with a removable cover. The sensing
clement is embedded in synthetic resin. The connection terminals are accessible after
removal of the cover. To introduce the cable through the wall, a grommet, cable gland
or sealing compound is required (also refer to illustration below). For wall mounting, a
cable entry gland can be screwed into the bottom ofthe housing
Technical data
®
El
XE
wm LE
UX
x
Directives and Product standard EN 60730-1
Standards ‘Automatic electrical controls for
household and similar use
Degree of protection Protection degree of housing IP 54 according to EN 60529
Protection class Il according to EN 60730-1
General device data Electrical connections
Connection terminals interchangeable
Cable entry for cable gland (e.g. M16 x 1.5)
Color Cover RAL 9003
Base RAL 7001
213
Siemens (Outside Sensors QAC. ‘CE10181 ten
Building Technologies 2015-01-28Dimensions
11.2.1 EXTERNAL SENSOR
“To connect this accessory, 360 gure to side (terminals 45)
and te netctons supphed wit ine sensors i
‘SETTING THE “Kt CLIMATE CURVE
When the extemal sensor is connected to the boiler. the
electronic board gusts. the flow temperature calculated
Sccordng1o he sat Kt cooticent Sole! he required eve by
presi se '2s indicated in the chart in annex SECTIO!
E for selecting the most appropriate one (00 to $0),
KEY TO CHART - “SECTION” E
jue Flow temp is Ouiside temp
“Kt curve for Outdoor Sensor” for BAX! Luna Duo Tect GA range
Ben (R/R) / (1/T-1/T)
SIEMENS
@acse
(© Siemens Switzriand Lt, 2005 Subject to change
Siemens (Outside Sensors GAC ‘cEI0181 140
Building Technologies 2015-01-28