Eng Seng Cement Products Pte LTD: Enhancing The Building Industry Since 1961

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

Eng Seng Cement Products Pte Ltd

enhancing the building industry since 1961

2
2
TYPICAL PAVEMENT TYPICAL BLOCK TYPICAL BASECOURSE REQUIREMENTS
APPLICATION THICKNESS(MM)
TYPE OF MATERIAL THICKNESS (mm)

(i) Light to medium duty (a) Quarry dust


e.g. Footpaths, jogging, 80MM (footpaths) WRPP
tracks, residential driveways (b) Crusher run
100 to 200 mm
(driveways)
(ii) Heavy duty
 HJ5RDGVIDFWRU\ÀRRUV 00 (c) Crusher run
(road & container 225 to 600 mm
container yards, aircraft
yards)
parking aprons
(d) Lean concrete
(very heavy 225 to 600 mm
concentared roads)

GENERAL INFORMATION
The thickness and design of
a concrete segmental
pavement is subject to:

! 7UDI¿FYROXPHHVWLPDWLRQ
> Soil & subgrade investigation
> Surface design
> Basecourse thickness design
> Design considerations for low-
strength subgrades or irregular
shaped areas

COMPRESSIVE STRENGTH
80MM - 49MPa
100MM - 49MPa

TOLERANCE
Thickness of any paver shall be ±3mm

3
Basecourse
Talking the existing sub-grade / soil conditions and
WKH DQWLFLSDWHG WUDI¿F ORDGLQJ LQWR FRQVLGHUDWLRQ DQ
DGHTXDWHWKLFNQHVVRIZHOOFRPSDFWHGEDVHFRXUVHPXVW
EH SURYLGHG WR HQVXUH JRRG SDYHPHQW SHUIRUPDQFH
([LVWLQJ ELWXPHQ RU FRQFUHWH VXUIDFHV QHHG QRW EH
UHPRYHGDQGFDQDFWDVJRRGVXEJUDGH

Sand Bedding Layer


A layer of sand should be loosely spread and screeded to
a uniform thickness such that its compacted thickness
would be approximately 30mm. It is important that the
sand layer remains undisturbed prior to the laying of
blocks.

Laying The Blocks


Paving blocks are placed side by side on the sand bed
with gaps of approximately 2mm between adjoining
blocks.

Blocks Cut And Fit


Paving blocks can be cut to fit and awkward corners

Pavement Compaction
Block pavement is compacted with a hand -guided
plate vibrator until it is embedded in the sand layer.
Type C7, C7A, C8, C8A, C8B
6FDOH

5
High Quality Finish, Concealed Services

R
Residential
id ti l - Hi
Highh rise
i Residential
R id ti l - Low
L rise
i Commercial
C i l / IIndustrial
d ti l

Material Panel Dimensions


)LQH$GMXVWPHQW
7
7KLFNQHVV better control of
Ferroconcrete PP DOLJQPHQW
 PP ZLGWK
PPZLGWK

FerroLite Partition
Wall System

Product P
Performance
Strength & Robustness
S
7
7HVWHGWR66%6
3DUW
3

Fire Resistance:
F

KUKU>%6
3DUW@
3

Sound Transmission Clss


S
'% $ >$670(@ Fastener
Steel tie plate
I
Initial Surface Absorption
aand Carbonation Test:
7HVWHGWR+'%VSHFL¿FDWLRQV
7
6
7
Cert.No: N483303 Cert.No: 022-024