LG - Instruction Manual PDF
LG - Instruction Manual PDF
LG - Instruction Manual PDF
Rotary Screw
Air Compressor
LG Series
Instruction
Manual
Direct Drive
1. Safety Information…………………...………………………………………………………4
1.1 Safety Alert Symbols………………………………………..……………………………4
1.2 Safety Precautions………………………………………………...……………………...5
1.3 Pressure……………………………………..…………………………………………….5
1.4 Fire and Explosion…………………………..…………………………………………...6
1.5 Moving Parts………………………………………………..……………………………6
1.6 Hot Surfaces…………………………….……………………………….……………….6
1.7 Proper Compressed Air Applications…........................................………..6
1.8 Electrical Shock…………………………………………………….…………………….7
2. General Information…………………………………………………………………………8
2.1 Introduction………………………………………………………………………………8
2.2 The Compression Cycle………………………………………………………………….9
2.3 Compressor Lubrication and Cooling System………………………….……..……...10
2.4 Compressor Discharge System………………………………………….……………..10
2.5 Airend, Inlet Valve and Filtration System…………………………………………….11
2.6 Control Panel Layout...……………………………………………………………..12-14
2.7 LG Technical Data………………………………………………………………..16-17
3. Fluid Information…………………………………………………………………………..19
3.1 Fluid Guide……………………………………………………………………….……..19
3.2 Fluid Change and Recommendations…………………………………………....……19
4. Installation…………………………………………………………………………………..20
4.1 Compressor Mounting, Support and Location…………………….…………………20
4.2 Ventilation and Cooling………………………………………….…………………20-21
4.3 Piping Connection…………………………………………………………..............22-23
4.4 Fluid Level Inspection……………………………………………….…………………23
4.5 Electrical………………………………………..………………………………….23-24
4.6 Motor Rotation Inspection………………………………………………...…………...25
4.7 Fan Rotation Inspection ………………………………………………….……………26
5. Operation………………………………………………………………………….………...26
5.1 Routine Operation………………………………………………….…………………..26
5.2 Operating Procedures (Electrical Control Panel)………………………………27-28
5.3 Display Unit Status and Operations………………………………………………29-32
5.4 Customer Parameter and Functions…………………………………….…………32-35
LG series Page 2
TABLE OF CONTENTS
LG series Page 3
Safety Information
Thank you for choosing Kaishan Compressor. Please read this instruction manual carefully
before using the compressor. This manual must be kept in the safe place for future reference.
Kaishan Compressor’s authorized distributors provide maintenance service for LG series rotary
screw compressors. A certified technician is required to ensure compressors maintenance is
safely handled. By following the instructions in this manual, the user will minimize possibility of
an accident throughout the useful life of this equipment.
Key hazards are used throughout this manual. The level of hazards seriousness is symbolized as
follows:
LG series Page 4
Safety Information
This manual describes the safety precautions, structure and functions of all systems and
components, as well as the operation and maintenance methods for the LG series rotary screw air
compressors. The owner and operator shall read the manual carefully. Only after thorough
understanding should the machine be operated for the first time. This manual gives you a general
description of the, mechanical and electrical systems and maintenance. However, if you have any
questions about operating and maintenance of the compressor; please contact your authorized
distributor or our service department personnel.
Do not modify the compressor and/or controls in any way except with written factory approval.
While not specifically applicable to all types of compressors with all types of prime movers,
most of the precautionary statements contained herein are applicable to most compressors and
the concepts behind these statements are generally applicable to all compressors.
Failure to follow any of these precautions may results in severe personal injury,
death, property damage and/or compressor damage
1.3 PRESSURE
A properly sized pressure relief valve must be installed in the discharge piping ahead (upstream)
of any shutoff valve (block valve), heat exchanger, orifice or any potential blockage point.
Failure to install a pressure relief valve could result in the rupturing or explosion of some system
component. Relieve all pressure internally to the compressor prior to servicing. Do not depend
on check valves to hold system pressure. Do not change the pressure setting of the pressure relief
valve, restrict the function of the pressure relief valve, or replace the pressure relief valve with a
plug. Over pressurization of system or compressor components can occur, resulting in death,
severe personal injury or property damage. Do not operate the compressor at pressures in excess
of its rating. Never use plastic pipe, rubber hose, or soldered joints in any part of the compressed
air system. Failure to ensure system compatibility with compressor piping is dangerous.
LG series Page 5
Safety Information
Clean up any spills of lubricant or combustible liquid immediately. Keep sparks and flame away
from the compressor. Do not permit smoking during servicing, such as checking or adding fluid.
Wipe down spills immediately using industrial cleaner as required. Do not use flammable
material for cleaning purposes. Do not operate the compressor in a hazardous environment unless
the compressor has been specially designed for that environment. Wear personal protective
equipment including safety goggles and clothing during servicing the compressor. Never use a
flammable or toxic solvent for cleaning the air filter or any parts.
Keep hands, arms and cloths away from the coupling and fans of the compressor. Do not remove
any guards or cabinet panels or attempt to service any compressor part while the compressor is
operating.
Do not touch any hot surface and parts during the compressor’s operation. Keep all body parts
away from air/oil receiver tank, steel tubing, air end and after-cooler. Wear personal protective
equipment including gloves while servicing the compressor.
Air from this compressor will cause severe injury or death if used for breathing or food
processing. Air used for those processes must meet OSHA and applicable industry regulations.
This compressor is designed for use in the compression of normal atmospheric air only. No other
gases, vapors or fumes should be exposed to the compressor intake, nor processed through the
compressor. Keep personnel away from the compressed air discharge. Use compressed air for
cleaning purpose, only with effective chip guarding and personal protective equipment which
meet OSHA standard and/or any federal, state, local codes, standard and regulation.
LG series Page 6
Safety Information
Never start the compressor unless it is safe to do so. Do not attempt to operate the compressor
with a known unsafe condition. Tag the compressor and render it inoperative by disconnecting
and locking out all power at the source or otherwise disabling its prime mover so others who
may not know of the unsafe condition cannot attempt to operate it until the condition is corrected.
Install, use and operate the compressor only in full compliance with all pertinent OSHA
regulations and/or any applicable Federal, State, and Local codes, standards and regulations.
Never assume it is safe to work on the compressor because it is not operating. Many installations
have automatic start/stop controls and the compressor may start at any time.
- Follow all maintenance procedures and check all safety devices on schedule.
- Do not rely on the discharge check valve to isolate the compressed air service line
NOTICE
- Keep panels closed at all times and stay away from hot surfaces to prevent hazards
Every effort has been taken to ensure complete and correct instructions have been included in
this manual. However, possible product updates and changes may have occurred since printing
this manual. Kaishan Compressor reserves the right to change specifications without incurring
any obligation for equipment previously or subsequently sold.
LG series Page 7
General Information
2.1 INTRODUCTION
The LG series offer models with power ranging from 10 hp to 250 hp (7.5 kw to 160 kw). These
direct driven compressors have standard full load pressure rating from 100 psi to 175 psi (7bar to
13bar). The compressor is a single stage, positive displacement, fluid-flooded rotary screw. A
complete package consists of following:
LG series Page 8
General Information
When the compressor is operating, a partial vacuum is produced at the compressor inlet. Fluid is
injected into the compressor unit and mixed with the air. The fluid has three basic functions:
As a coolant, it controls the rise in air temperature normally associated with the heat of
compression.
It seals the leakage paths between the rotors and stator and also between the rotors
themselves.
It acts as a lubricating film between the rotors allowing one rotor to directly drive the
other, which is an idler.
After air/fluid mixture is discharged from compressor to the reservoir, fluid is separated from the
air in the separator tank. Compressed air then flows through the after-cooler for moisture
removal while the lubricant is being cooled by the fluid-cooler for re-injection.
LG series Page 9
General Information
The lubrication and cooling system consists of a reservoir, centrifugal fan, fan motor, aluminum
finned fluid-cooler and after-cooler, thermal valve & fluid filter. High pressure forces the
lubricant through a series of direction changes in the reservoir where it is separated from the air.
The fluid is then delivered to the thermal valve and fluid-cooler. Cooled fluid will be filtered
before being re-injected back into the compressor.
Ambient air is being forced through the cooler fins by the centrifugal fan, which cools the fluid
and compressed air in the cooler tubes. The after-cooler helps separate the water content in the
discharge air, and through the automatic condensate drain, the water will be drained. This avoids
water contamination problems downstream (in service lines). Cooler fins must be kept clean at
all times.
Fluid from reservoir circulates to the thermal valve. The thermal valve is fully closed when the
fluid temperature is below 70°C (158°F). Fluid (below 158°F) will bypass the thermal valve and
inject directly to the airend. As the discharge temperature rises above 80°C (176°F), due to heat
of compression, the thermal valve begins to open and fluid will be circulated to the cooler.
Air/fluid mixture has been forced into reservoir after compression. The reservoir has two basic
functions:
The sight glass enables the operator to visually monitor the reservoir fluid level. Fluid is added to
the reservoir by removing the fluid filling cap after all system pressure is relieved. The fluid
level should remain at the top red lines on the sightglass. Fluid refill is required once its level
drops below the lower red line.
LG series Page 10
General Information
The minimum pressure check valve assures the reservoir maintains a minimum pressure between
58 psig and 72 psig (0.4Mpa and 0.5Mpa) during unloading conditions. This pressure is
necessary for air/fluid separation and fluid circulation.
SKK airend
LG series Page 11
General Information
——Set Button/ Loading / unloading Button: After modification, press this to confirm
and save modified data;When the compressor is running ,press this to load or
unload under a certain pressure.
LG series Page 12
General Information
——Shift button /Enter button: This button services as shift button when data are modified
and services as enter button when menu is selected.
——Back button / Reset button: This button services as back button when operate menu
return to parent menu; reset is carried out by pressing and hold this button when failure
shutdown.
I
GAS T:80C
GAS P:0.8MPa
STATE NORMAL STOP
O
0S REMOTE
C
S C
S——Set Button: Press this button to confirm the input data to be saved after modification of the
data.
——Up button: Press this button to move upward during modification data. Or press this button
to select menu during the menu selection
——Down Button: Press this button to move downward during modification data. Or press this
button to select menu during the menu selection
——Cursor / Confirm Button: This button can be used as cursor during the data modification and
as confirm (enter) button during the menu selection
LG series Page 13
General Information
——Manual Loading / unloading Button: In the manual mode, press this button to loading or
unloading under a certain pressure.
C——Return / Reset Button: Press this button to return to upper menu during the menu operation.
Or press this
button to reset the machine for 5 seconds to reset when the unit is stopped in failure.
LG series Page 14
General Information
Always check power supply before you service the unit. The power indication
light could be in faulty status.
LG series Page 15
General Information
LG series Page 16
General Information
LG series Page 17
General Information
The dimensions listed are for air-cooled units. Above 37 kw, the water-cooled units
are available. Please contact the manufacturer for the dimensions of the water-
cooled units.
LG series Page 18
Fluid Information
Sight Glass
Do not use different fluid. Using different fluid will void compressor’s warranty.
Kerry 4000
Every 4,000 hours Every 2,000 hours Every 3,000 hours
Or equivalence*
LG series Page 19
Installation
Compressor should be located on a flat surface in a clean, well-lit and well-ventilated area. The
location must have sufficient access for maintenance equipment and lifting vehicle. Four feet (4’)
of clearance around the compressor is recommended for daily inspection and easy access to all
compressor components. The area must have sufficient lighting for technicians to safely operate
the compressor as well as perform maintenance work. The location should be free from standing
water.
The compressor’s base must be securely bolted to the floor with lag bolts. Rubber pad with 5 -
15mm thickness or pliable material should be placed under the bottom of the base if floor surface
is uneven or irregular. A stationary compressor will prevent accidents such as broken piping or
electrical connections. Do not over tighten the lag bolts because this may cause the frame to twist
or bind which could results in possible breakage of fluid coolers, piping and the reservoir.
Brand new compressor has “Orange Color” shipping bracket installed under
airend assembly. Please remove the bracket after the unit is installed.
NOTICE!
Removal or paint over of safety labels will be a safety hazard. This could result in
personal injury or property damage. Warning signs and labels should be
conspicuous and on a bright legible surface. Do not remove any warning, caution or
instructional material attached with unit.
Ambient temperature should not exceed 40°C (104°F). High ambient temperatures may result in
high air temperature shutdown.
LG series Page 20
Installation
Do not install and operate compressor if the ambient temperature is below 5°C
(41°F). Pre-heat option must be installed with the unit for lower ambient
NOTICE! temperatures.
The compressor air inlet must be located in the opposite direction to other compressors or heat
generating equipment. The object is to avoid hot air being drawn into the system. Do not block
the exhaust air from cooler or fan. Hot exhaust air must be vented outside through a duct to
prevent high ambient room temperature. The compressor room must be properly ventilated to
avoid compressor high temperature shutdown.
Maintain clean & fresh air, dust free, metal particle free and chemical vapor free in
the compressor’s room. Housing the compressor within a poorly ventilated
enclosure will cause higher operating temperature.
All models are intended for indoor installation; however, it is possible, with certain
modifications, to accommodate some outdoor locations. Models with standard enclosure are
water-resistant but not water tight. Shelter is needed to protect the unit from rain, snow and
freezing temperatures. An optional weather hood or air grille could be installed to protect
compressor against blowing rain and snow as well as cabinet heater additions if ambient
temperature will be below 5°C (41 F).
LG series Page 21
Installation
Before installation, review the complete air systems layout, which includes compressor(s),
receiver tank, dryer(s), line filter(s), pipe size, water drain and isolator valves. Never join pipes
or fittings by soldering. Never use PVC pipe or non-genuine rubber hose in the air system. Use
flexible connections to prevent pipe load from being transmitted to the compressor. Never use a
different pipe size other than the manufacturer specification for the compressor unit.
A service line shut off valve must be installed after the compressor air outlet connection with a
pressure relief valve installed to release compressed air to the atmosphere. For a single
compressor and air receiver tank, manual shut off valves are typically being installed. A union
connector must be installed after the ball valve (quarter turn, shut off valve) at the compressed
air outlet. This will allow unit isolation for maintenance.
Release system pressure by opening manual pressure relief valve prior to servicing.
Failure to relieve system pressure could result in death or serious injury and
property damage.
The compressor after-cooler comes with an automatic condensate drain. The drain line should be
installed to remove the condensate during compressor operation.
A receiver tank should be installed if compressed air demands fluctuate. Service line piping is
recommended to be sized to match the compressor’s discharge connector. All piping & fittings
should be rated to withstand greater pressure than the discharge pressure. Isolation valves &
drain valves are installed to isolate the compressor when service is required. These valves should
have water drip legs with the drain direction facing downward to the floor. Piping should all line
up properly with an adequate loop radius or bend radius given for easy installation and to prevent
bending stress, flow restriction and damage due to thermal expansion. Piping support brackets
must be mounted independent of the compressor and motor. This will avoid damage caused by
vibration.
LG series Page 22
Installation
Pressure relief valves are sized to protect the system. Never change the pressure setting or tamper
with the valve. Only the valve manufacturer and their authorized representatives are allowed to
make such changes.
Pressure relief valves are used to protect system integrity in accordance with safety
standards. Failure to provide properly sized valves will result in death or serious
injury.
Pressure relief valves are installed prior to any potential blockage point such as shutoff valves,
heat exchangers and discharge silencers. Ideally, the valve should be threaded directly into the
pressure point it is sensing, not connected with tubing or pipe. Always direct discharge from
relief valves to a safe area away from personnel.
Inspect the fluid level when the compressor is in shut down mode. Fluid level is indicated on the
reservoir sight glass (see figure 3-1). The maximum fluid level is at the top red-mark. Add fluid
until the top red-mark is reached.
4.5 ELECTRICAL
Before installation, the electrical supply should be checked for adequate wire size and capacity.
User must comply with national & local electrical codes. The codes specify the surrounding
clearance requirement for the electrical panel. Wiring work should be undertaken only by a
qualified electrician in compliance with OSHA, national or local electrical code. Kaishan
compressor provides wiring diagrams for user reference. Refer to the electrical control schematic
in the parts manual for wiring diagrams. Genuine fused disconnect switch or circuit breaker
should be purchased from the manufacturer. Any unreasonable voltage imbalance (5%) between
phases must be eliminated and low voltage problems must be corrected to prevent excessive
current draw. Air compressors must be grounded in accordance with applicable codes,
regulations and requirement.
LG series Page 23
Installation
All electrical supply cables must be adequately sized to prevent overheating due to
current draw.
Enclosure panels and drive grille must be fastened in place before starting the
compressor and never removed before lock out / tag out of the main power supply.
A starter hole is provided for an incoming power connection. If a different location for the starter
hole is needed, the certified technician must make sure to keep control box clean after the hole is
created. The original hole must be capped if another hole is used. Inspect incoming voltage to
match the compressor’s specification. Inspect motor starter and overload heater sizes. Check all
electrical connections L1-L2-L3 for tightness and cleanliness.
LG series Page 24
Installation
Motor rotation must be checked after the wiring has been installed. Operating the compressor in
incorrect rotation will result in severe damage to the compressor and warranty coverage will be
voided. Motor rotation can be viewed through the opening in the drive grille. The drive motor
end of the compressor is marked with an arrow noting the proper rotation.
To inspect rotors rotation, pull out the “EMERGENCY STOP” button and press once, quickly
press the “START” and “STOP” button in sequence, allowing the motor to turn 2 or 3
revolutions. Observe the drive shaft for correct direction. If reverse rotation is observed,
disconnect the power supply, reverse power input leads at the motor starter. Recheck for proper
rotation.
Fan motor rotation should be inspected. LG compressors uses n axial fan for cooling. Fan
rotation should be inspected when start-up. The fan must rotate in the direction indicated by the
arrow.
Always inspect fan. Never assume the fan rotation is correct based on the induced
air flow across the coolers. An axial fan cannot pull the airflow across the coolers
when rotating is in wrong direction; Incorrect rotation will cause high discharge
NOTICE! temperature.
LG series Page 25
Operation
Provisions should be made to have the instruction manual readily available to the
operator and maintenance personnel. If, for any reason, any parts of the manual
become illegible or if the manual is lost, have it replaced immediately. The
instruction manual should be read periodically to refresh one’s memory. This may
prevent a serious accident.
Before compressor start up, inspect fluid level in reservoir. After start up, observe the control
panel screen for operation status. Ensure the compressor is running at its optimum level.
Close the service valve to plant air distribution system. Allow pressure to build up within the
reservoir until compressor fully unloads. Press the stop button.
Always close the service valve when compressor is not being used. It prevents
back pressure from the service line and avoids leakage due to check valve failure.
NOTICE
Emergency shutdown. Press the emergency stop button or pull the circuit breaker
at the main power terminal.
NOTICE
LG series Page 26
Operation
——Shift button /Enter button: This button services as shift button when data are modified
LG series Page 27
and services as enter button when menu is selected.
——Back button / Reset button: This button services as back button when operate menu
return to parent menu; reset is carried out by pressing and hold this button when failure
shutdown.
LG series Page 28
Operation
WELCOME USING
SCREW COMPRESSOR
AIR T:20℃
AIR P:0.60MPA
NORMAL STOP
C001 NEAR
RUN PARAMETER
CUSTOMER SET
FACTORY SET
LG series Page 29
Viewing Run Parameter:
Press “▼”or “▲” to move the black cursor to “RUN PARAMETER”, press ““ to pop
up submenu:
MOTORS CURRENT
MAINTENANCE SET
Press ““ again to pop up:
R 0.0
0.0
S 0.0
0.0
If the menu popped up is at the lastT level,
0.0 the black cursor will disappear. Press the return
button “C” to return to the upper menu0.0 or the main page. If the operation stops at a
certain page, it will automatically return to the main page shortly.
Using moving buttons “▼”, “▲”; confirm button ““ to view other parameters like:
Maintenance Parameter, History Failure, Production Time, Current Failure and etc. and to
return to the upper menu by using return button “C”.
Parameter Modification
---------- User Parameter and Manufacturer Default Parameter can not be modified during running
status and stop delay period ------------
To view and modify User Parameter you can use the same method of “Viewing Run Parameter”,
If you want to modify “HOST START”, please follow the instructions below:
LG series Page 30
Operation
Press “▼”or “▲” black moving cursor to “Customer Parameter” and then press “” to pop
up:
SET P、T
SET TIME E
OPERATION MODE
Press “▼”move the cursor to “SET TIME”and then Press “” again to pop up:
BLOCKING MODE
2
HOST START:0012S
0
0
FAN START :0006S 4
年
STAR DELAY:0010S 2
Now you can view the data, if you press ““ again, the following interface will be popped 月 up
LOAD DELAY:0006S
which requires you to input password. 2
2
2
日
0
星期日 0
ENTER PASSWORD 4
年
**** 2
月
Attention: User Password can be modified in the “Customer Parameter”; Factory Password 2
2
2
0
is fixed to be 日
0
星期日 4
Now you can modify the data in the previous page. There will be a blinking cursor.年
“▼”and “▲” now turn to be descending and increase Buttons to modify the data. When 2
finish modification, press “M” to confirm and save. 月
2
2
For example: 日
星期日
when
HOSTthere is a﹡displayed
START:0012S * at
theSTART
FAN up right corner which means
:0006S
LOAD DELAY:0006S
LG series Page 31
2
0
0
4
年
2
When pressing “▲” or “▼” button to move black cursor to “HOST START ” and press
““ to confirm. Now the blinking cursor with﹡appears. User can press “▼”、“▲” and
““ button to modify the present data. Press “S” button to confirm when finished. The
blinking cursor will disappear. “▲”, “▼” and ““ can be used for modifying other parameter
and data. If there is no need for further modification, press “C” to go back to upper menu or
main menu.
LG series Page 32
The machine will not stop until the load free
STOP DELAY 0010S
running status lasting till this time
LG series Page 33
During interlocking operation, if one air
compressor continuously operates for time
period more than time set here and rest
9999 time of one air compressor in interlocking
TURN TIME
Hours network has reached the time set here,
alternative rest is achieved by starting the
resting air compressor and stopping the
operating air compressor
LG series Page 34
Set this value to “0” will make the oil filter
OIL FILTER 9999s
alarm not available
NEW USER PIN **** **** Customer could modify the user password
⑷.Manufacturer Parameters
The difference between manufacturer parameters and user parameters is in that manufacturer
parameters can be looked over and modified with manufacturer password, but its operation method
is the same as that of user parameters. Please refer to following table for main functions and
purposes.
LG series Page 35
Alarm when the air exhausting temperature
STOP T. 110℃
reaches this set value.
PROD NO. ****** The manufacturer input the product No. of the unit
LG series Page 36
Operation
Automatic control (ON/OFF mode: Local control; Loading/unloading method: Automatic and
Manual)
LG series Page 37
Operation
4) Normal shutdown:
Press the button “O”, the load-solenoid valve will lose power and unload-solenoid valve will
be energized with power, the inlet valve will close. After the delay time (stop delay) is
reached, the motor contactor will lose power, the unit and fan will stop RUNNING. After
the restart delay operation is completed, the unload solenoid valve will lose power. Only
pressing the button “︱”will restart the motor.
Remote automatic control (method of starting and stopping: remote; method of loading:
automatic)
Remote automatic control and local automatic control are basically the same. For remote
automatic control, start-up or stoppage of the compressor can be achieved by the remote
control switch. For Local manual control (method of starting and stopping: local; method of
loading: manual), the start and stop control are the same as the automatic control, but the
compressor remains in unloaded status after start-up. Loading is carried out by pressing
loading /unloading button “S” to load. When the air pressure is greater than the relief
pressure, the device unloads automatically. If loading/unloading button “S” is not pressed,
the compressor will stay unloaded until it stops. During unloading, press loading/unloading
button “S” to load. During loading, press loading/ unloading button “S” to unload.
The remote automatic control is almost the same as the local manual control; the only
difference is that the start and stop unit is controlled by remote control.
LG series Page 38
Operation
When the discharge temperature is higher than the fan’s starting temperature, the fan starts to
operate; when the discharge temperature is lower than fan’s stopping temperature, the fan stops.
When electrical failure or high discharge temperature appears during compressor operation, the
controller stops the motor’s operation immediately. The air compressor can only be restarted
after the failure is eliminated. In case of emergency, press the emergency stop button to cut off
the power supply to the controller and contactors.
Prompts on display
LG series Page 39
Operation
LG series Page 40
Operation
Electronic
Failure Display Reason
failure
LG series Page 41
Operation
LG series Page 42
Operation
Press Down button “▼” or Up button “▲”, to move the black scroll bar to “RUN PARAMETER”
menu, then press Enter button “”, the lower menu would be propped out:
MOTORS CURRENT
MAINTENANCE SET
Press Down key “▼” always and the following menu will appear:
HISTORY FAULT
THIS FAULT
Press Enter key “” and the following failure causes will appear:
0170℃
In this case, just check if the temperature sensor is disconnected and if the sensor is damaged, etc.
LG series Page 43
⑵. Common Failures and Causes
Failure Reason Disposal method
Air Exhaust
Bad vent condition, Oil lacking Check the vent condition and lubricant
Temperature too
etc. amount etc.
high
Temperature Sensor
Cable off or PT1OO damaged Checking the wiring and PT100
Failure
The pressure too high or the Check the pressure and the pressure
Over Pressure
pressure sensor failure sensor
Pressure Sensor Cable off, Sensor damaged or Check the wiring and sensor
Failure the cable connected reversed transformer
Wrong Wiring, Incorrect Data Checking the wiring and set the data
Short Circuit
setting etc. correctly
LG series Page 44
Fan damaged, Contactor
Fan stopped Check the wiring and control output
damaged, no control output
Overload or Rotor Host start time set to a Reset the host starting time to be
locking during valueless than the star angel longer than star angel delay + Load
starting process time delay delay time
Main Contactor
The emergency button loose Check the wiring
activate time to time
Air Exhaust
Bad vent condition, Oil lacking Check the vent condition and lubricant
Temperature too
etc. amount etc.
high
Temperature Sensor
Cable off or PT1OO damaged Checking the wiring and PT100
Failure
The pressure too high or the Check the pressure and the pressure
Over Pressure
pressure sensor failure sensor
LG series Page 45
Servicing
LG compressor requires the minimum amount of inspection and maintenance. The controller and
indicator alerts the operator to perform required maintenance or repair unit problems.
i. Press the emergency stop button and remove the right side cabinet panel (if applicable).
ii. Check the pressure gauge reading on reservoir and wait until reservoir pressure drops to
approximately 0.05 Mpa (7psig).
iii. Close the 1/4 turn valve on the blow-down valve.
iv. Remove the drain plug and attach the 1/4 NPT barb fitting and drain tube (supplied with
the unit) to the drain on the oil/air separator tank.
v. Slowly open the 1/4 turn valve on the drain of oil/air separator tank. The pressure
remaining in the tank will force the fluid out. When air begins to escape from the tank,
close the valve.
vi. After closing the valve, remove the tubing and barb fitting and reinstall the drain plug.
vii. Remove the plug from the fluid fill port and refill the reservoir with the appropriate
amount of Kerry 4000 fluid.
viii. Before starting the compressor opens the 1/4 turn valve on the blow-down valve to
ensure the blow-down valve functions correctly.
The 1/4 turn valve on the blow-down valve MUST be open for the unit to
blow down during regular unit operation.
NOTICE
LG series Page 46
Servicing
Intake filtration equipment supplied from the factory may not be adequate for
extremely dirty applications or some forms of dust or vapors. It is the customer’s
responsibility to provide adequate filtration for those conditions. Warranty will
NOTICE
be voided if inadequate filtration causes a failure.
As indicated by the fluid filter maintenance indicator when the fluid is at normal operating
temperature
Every 2,000 hours
Every fluid change
The fluid filter maintenance indicator may read high upon start up on cool
mornings due to sluggish fluid creating higher than normal differential
NOTICE pressures. Monitor indicator after the fluid warms up.
LG series Page 47
Servicing
Every 1000 hours Clean air filter or replace with new element.
Replace fluid.
LG series Page 48
Troubleshooting Guide
Loose wire connections Check all wiring terminals for contact and
tightness
Compressor shuts High ambient temperature Make fresh air intake openings or install
down during loaded ducts to discharge the hot air.
condition
Low incoming voltage Check voltage and power source, or
contact local power company.
Line pressure rises Control system air leakage Check for leak
above unload pressure
LG series Page 49
set-point causing loss of pressure
Air Intake valve stuck open Remove the intake hose and check the
inlet valve for proper operation
Jammed air inlet valve Check and repair air inlet valve
assembly
LG series Page 50
Low air capacity Plugged air filter Clean air filter or replace with new element
delivery
Air Intake valve failure Remove the intake hose and check the
inlet
Excessive oil carry over High oil level Check oil level
in discharge
compressed air. Plugged oil orifice valve Clean or replace as necessary
Air Intake valve stuck open Remove the intake hose and check the
inlet
LG series Page 51
Air Intake valve stuck open Remove the intake hose and check the
inlet
Air flow into the main Increase pipe size. Checks filter cartridge
network restricted failure.
Oil vapor leak from air Air inlet valve failure Check and replace as necessary
filter when compressor
stops Minimum pressure valve Check for leaks and replace as necessary
failure
Excessive Fluid Different oil is being used. Use KHE genuine fluid.
Consumption
Separator element Check and replace as necessary.
damaged
Oil level too high Drain off oil until the correct level.
LG series Page 52
Standard Terms and Conditions
These terms and conditions govern the sale of Products (“Rotary Screw Air Compressors and
parts”) and provisions of services by Kaishan Compressor Co. Ltd (Seller) and its authorized
representative or buyer. These terms and conditions (“Agreement”) take precedence over Buyer’s
supplemental or conflicting terms and conditions to which notice of objection is hereby given.
Neither Seller’s commencement of performance or delivery shall be deemed or construed as
acceptance of Buyer’s supplemental or conflicting terms and conditions. Kaishan Compressor’s
failure to object to conflicting or additional terms will not change or add to the terms of this
agreement. Buyer’s acceptance of the Products and/or Services from Seller shall be deemed to
constitute acceptance of the terms and conditions contained herein.
Orders: All orders placed by Buyer are subject to acceptance by Seller. Orders may not be
canceled or rescheduled without Seller’s written consent. All orders must identify the products,
unit quantities, part numbers, applicable prices and requested delivery dates of the Products being
purchased. Seller may at its sole discretion allocate Product among its Buyer. Seller may
designate certain Products and Services as non-cancelable, non-returnable and the sale of such
Products shall be subject to the special terms and conditions contained in Seller’s Customer
Acknowledgement or Non-Returnable Product Form, which shall prevail and supersede any
inconsistent terms and conditions contained herein or elsewhere.
Prices: The prices of the Products are those prices specified on the front of the invoice or
contained within an agreed written contract. Price quotations shall automatically expire in thirty
(30) days from the date issued, or as otherwise stated in the quotation.
Taxes: Unless otherwise agreed to in writing by Seller, all prices quoted are exclusive of
transportation and insurance costs, duties, and all taxes including federal, state and local sales,
excise and value added, goods and services taxes, and any other taxes. Buyer agrees to indemnify
and hold Seller harmless for any liability for tax in connection with the sale, as well as the
collection or withholding thereof, including penalties and interest thereon. When applicable,
transportation and taxes shall appear as separate items on Seller’s invoice.
Payment: Payment may be made by check, money order, credit card, or wire transfer (all fees are
borne by the Buyer). Where Seller has extended credit to Buyer, terms of payment shall be net
thirty (30) days from date of invoice, without offset or deduction. On any past due invoice, Seller
may impose a monthly interest rate. If Buyer fails to make the required payments the Seller will
impose the interest rate each month. If Buyer fails to make each payment when it is due, Seller
reserves the right to withdraw credit and thereby suspend or cancel performance under any or all
purchase orders or agreements in which Seller has extended credit to Buyer. In the event of
default by Buyer, Seller shall be entitled to costs, fees, and expenses including but not limited to
recovery of attorney fees, court costs and fees, and collections costs.
LG series Page 53
Standard Terms and Conditions
Delivery and Title: The locations of shipment delivery will be made according to the Seller and
Buyer agreement. Title and risk of loss pass to the Buyer upon delivery of the Product to the
carrier. Seller’s delivery dates are estimates only and Seller is not liable for delays in delivery or
for failure to perform due to causes beyond the reasonable control of the Seller, nor shall the
carrier be deemed an agent of the Seller. A delayed delivery of any part of an Order does not
entitle Buyer to cancel other deliveries. Kaishan Compressor will comply with various federal,
state and local laws and regulation concerning occupational health, safety and environment
concerns. Buyer has full responsibility to comply with those laws and regulations during the
installation and operation of the equipment.
Acceptance / Returns: Shipments will be deemed to have been accepted by Buyer upon delivery
of the said shipments to Buyer unless rejected upon receipt. Buyer shall perform all inspections
and tests. Buyer deems necessary as promptly as possible but in no event later than 7 days after
receipt of Products, at which time Buyer will be deemed to have irrevocably accepted the
Products. Any discrepancy in shipment quantity must be reported within 7 days after receipt of
Products. Buyer may not return Products without a Return Material Authorization (“RMA”)
number. RMA’s valid for 30 days from the date issued.
Standard Warranty: Buyer will honor Product warranties and indemnities authorized by the
manufacturer, including any transferable. 90 days warranty is given for service parts from receipt
date. Seller warrants to Buyer that Products purchased hereunder will conform to the applicable
manufacturer’s specifications for such products and that any value-added work performed by
Seller on such Products will conform to applicable Buyer’s specifications. If Seller breaches this
warranty, Buyer’s remedy is limited to (at Seller’s election) (1) refund of Buyer’s purchase price
for such Product (without interest), (2) repair of such Products, or (3) replacement of such
Products provided that such Products must be returned to Seller, along with acceptable evidence
of purchase within 13 days from date of delivery, transportation charges prepaid. No warranty
will apply if the Product has been subject to misuse, neglect, accident or modification.
Limitation of Liabilities: Buyer shall not be entitled to, and Seller shall not be liable for, loss of
profit or revenue, promotional or manufacturing expenses, overheads expenses, business
interruption cost, loss of data, removal or reinstallation costs, injury to reputation of buyer,
punitive damages, loss of contractor orders or any indirect, special, incidental or consequential
damages of any nature. Buyer’s recovery from seller for any claim shall not exceed the purchase
price paid for the affected products irrespective of the nature of the claim whether in contract, tort,
warranty, or otherwise. Buyer will indemnify, defend and hold seller harmless from any claims
based on (a) Seller’s compliance with buyer’s designs, specifications, or instructions, (b)
Modification of any products by anyone other than Seller, or (c) use in combination with other
products not supplied by seller.
LG series Page 54
Standard Terms and Conditions
Export Control: Buyer certifies that it will be the recipient of the Products delivered by
Seller. Seller will void product warranty if buyer resales and exports the product without
manufacturer’s agreement. Buyer acknowledges that the Products are subject to the
export/import control laws and regulations of various countries, including the Export
Administration Laws of the United States. Products sold by Seller cannot be transferred, sold or
re-exported to any party on the List or Restricted Person List of the U. S. Department of
Commerce Bureau of Industry and Security, any party designated by the U.S. Treasury
Department’s Office of Foreign Assets Control, and any party debarred or sanctioned for nuclear
proliferation or terrorism reasons by the U.S. State Department.
Use of Products: Unless otherwise specified. Products sold by Seller are not designed, intended
or authorized for use in life support, life sustaining, nuclear, or other applications in which the
failure of such Products could reasonably be expected to result in personal injury, loss of life or
catastrophic property damage. If buyer uses or sales the Products for use in any such applications:
(1) Buyer acknowledges that such use or sale is at Buyer’s sole risk; (2) Buyer agrees that Seller
and the manufacturer of the Products are not liable, in whole or in part, for any claim or damage
arising from such use; and (3) Buyer agrees to indemnify, defend and hold Seller and the
manufacturer of the Products harmless from and against any and all claims, damages, losses, costs,
expenses and liabilities arising out of or in connection with such use or sale.
Force Majeure: Seller is not liable for failure to fulfill its obligations for any accepted Order or
for delays in delivery due to causes beyond Seller’s reasonable control including, but not limited
to, acts of God, natural or artificial disaster, riot, war, strike, delay by carrier, shortage of Product,
acts or omissions of other parties, acts or omissions of civil or military authority, Government
priorities, changes in law, material shortages, fire, strikes, floods, epidemics, quarantine
restrictions, acts of terrorism, delays in transportation or inability to obtain labor, materials or
products through its regular sources, which shall be considered as an event of force majeure
excusing Seller from performance and barring remedies for non-performance. In an event of
force majeure condition, the Seller’s time for performance shall be extended for a period equal to
the time lost as a consequence of the force majeure condition without subjecting Seller to any
liability or penalty. Seller may, at its option, cancel the remaining performance, without any
liability or penalty, by giving notice of such cancellation to the Buyer.
General: (a) Seller will comply with state law for any dispute from buyer. (b) Buyer may not
assign this Agreement without the prior written consent of Seller. Seller or its affiliates may
perform the obligations under this Agreement. This Agreement is binding on successor and
assigns, (c) Products, including software or other intellectual property, are subject to any
applicable rights of third parties, such as patents, copyrights and/or user licenses.
LG series Page 55
Contact Information
Customer Service:
Tel: 86-21-62882179
E-mail Address:
[email protected]
LG series Page 56