Item 2: Installation Ground Terminal Block - STI 2,5-PE/L/NTB - 3038642

This document provides information on an installation ground terminal block from Phoenix Contact. Key details include: - It is a 3-level spring-cage connection terminal block for wire sizes from 0.08-4mm2. - It meets safety requirements for individual circuit isolation and has a rated surge voltage of 4kV. - Technical specifications include a nominal current of 20A, operating temperature range of -60°C to 125°C, and fire protection ratings for rail applications.

Uploaded by

HashemAliHashem
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
78 views3 pages

Item 2: Installation Ground Terminal Block - STI 2,5-PE/L/NTB - 3038642

This document provides information on an installation ground terminal block from Phoenix Contact. Key details include: - It is a 3-level spring-cage connection terminal block for wire sizes from 0.08-4mm2. - It meets safety requirements for individual circuit isolation and has a rated surge voltage of 4kV. - Technical specifications include a nominal current of 20A, operating temperature range of -60°C to 125°C, and fire protection ratings for rail applications.

Uploaded by

HashemAliHashem
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

https://www.phoenixcontact.

com/us/products/3038642

Item 2
Installation ground terminal block - STI 2,5-PE/L/NTB - 3038642
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)

Installation ground terminal block, Spring-cage connection, cross section: 0.08 mm² - 4 mm², AWG: 28 - 12,
width: 5.2 mm, color: gray, mounting type: NS 35/7,5,  NS 35/15

Why buy this product


 The terminal blocks with knife disconnect zone in the upper level meet the safety requirement regarding individual circuit isolation of DIN VDE
0100-718

Key Commercial Data


Packing unit 1 STK

GTIN

GTIN 4017918902186
Weight per Piece (excluding packing) 18.160 g
Custom tariff number 85369010
Country of origin Germany

Technical data
General
Number of levels 3
Number of connections 5
Nominal cross section 2.5 mm²
Color gray
Insulating material PA
Flammability rating according to UL 94 V0
Rated surge voltage 4 kV
Degree of pollution 3

08/18/2017   Page 1 / 16
https://www.phoenixcontact.com/us/products/3038642

Installation ground terminal block - STI 2,5-PE/L/NTB - 3038642


Technical data
General
Overvoltage category III
Insulating material group I
Maximum power dissipation for nominal condition 0.77 W (the value is multiplied when connecting multiple levels)
Connection in acc. with standard IEC 60947-7-1/IEC 60947-7-2
Nominal current IN 20 A
Maximum load current 20 A (with 6 mm² conductor cross section)
Nominal voltage UN 400 V (phase conductor/phase conductor)
250 V (phase conductor/PE and phase conductor/N)
250 V (phase conductor/N)
Connection in acc. with standard IEC 60947-7-1
Nominal current IN (upper level) 16 A
Maximum load current (upper level) 16 A
Open side panel Yes
Relative insulation material temperature index (Elec., UL 746 B) 130 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 125 °C
Static insulating material application in cold -60 °C
Behavior in fire for rail vehicles (DIN 5510-2) Test passed
Flame test method (DIN EN 60695-11-10) V0
Oxygen index (DIN EN ISO 4589-2) >32 %
NF F16-101, NF F10-102 Class I 2
NF F16-101, NF F10-102 Class F 2
Surface flammability NFPA 130 (ASTM E 162) passed
Specific optical density of smoke NFPA 130 (ASTM E 662) passed
Smoke gas toxicity NFPA 130 (SMP 800C) passed
Calorimetric heat release NFPA 130 (ASTM E 1354) 27,5 MJ/kg
Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3

Dimensions
Width 5.2 mm
Length 97 mm
Height NS 35/7,5 50.5 mm
Height NS 35/15 58 mm

Connection data
Note Please observe the current carrying capacity of the DIN rails.

08/18/2017   Page 2 / 16
https://www.phoenixcontact.com/us/products/3038642

Installation ground terminal block - STI 2,5-PE/L/NTB - 3038642


Technical data
Connection data
Conductor cross section solid min. 0.08 mm²
Conductor cross section solid max. 4 mm²
Conductor cross section flexible min. 0.08 mm²
Conductor cross section flexible max. 4 mm²
Conductor cross section AWG min. 28
Conductor cross section AWG max. 12
Conductor cross section flexible, with ferrule without plastic sleeve min. 0.14 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max. 2.5 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min. 0.14 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max. 2.5 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic
0.5 mm²
sleeve, max.
Connection method Spring-cage connection
Stripping length 10 mm
Internal cylindrical gage A3

Standards and Regulations


Connection in acc. with standard CSA
IEC 60947-7-1/IEC 60947-7-2
IEC 60947-7-1
Flammability rating according to UL 94 V0
Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3

Environmental Product Compliance


China RoHS Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values