Cullagan HE Water Softener Owners Guide
Cullagan HE Water Softener Owners Guide
Cullagan HE Water Softener Owners Guide
High
Efficiency
Automatic
Water
Softener
Owners
Guide
Attention The installation, service and maintenance of this equipment should be rendered by a qualified and trained
service technician. Your local independently operated Culligan dealer employs trained service and main-
Culligan tenance personnel who are experienced in the installation, function and repair of Culligan equipment. This
Customer publication is written specifically for these individuals and is intended for their use.
We encourage Culligan users to learn about Culligan products, but we believe that product knowledge is
best obtained by consulting with your Culligan dealer. Untrained individuals who use this manual assume
the risk of any resulting property damage or personal injury.
NOTE This system is not intended for use where water is microbiologically unsafe or with
water of unknown quality.
WARNING! This device complies with part 15 of the FCC rules subject to the
two following conditions: 1) This device may not cause harmful
interference, and 2) This device must accept all interference received
including interference that may cause undesired operation.
This equipment complies with Part 15 of the FCC rules. Any changes or modifications not expressly ap-
proved by the manufacturer could void the user’s authority to operate the equipment. Changes or modifi-
cations not expressly approved by the party responsible for compliance could void the user’s authority to
operate the equipment.
CAUTION! To reduce the risk of fire, use only No. 26 AWG or larger
telecommunications line cord.
CAUTION! If the power cord from the transformer to the unit looks or becomes
damaged, the cord and transformer should be replaced by a Culligan
Service Agent or similarly qualified
person in order to avoid a hazard.
Products manufactured and marketed by Culligan International Company (Culligan) and its affiliates are
protected by patents issued or pending in the United States and other countries. Culligan reserves the right
to change the specifications referred to in this literature at any time, without prior notice. Culligan, Aqua-
Sensor, Tripl-Hull, and SoftMinder are trademarks of Culligan International Company or its affiliates.
Culligan International Company
9399 West Higgins Road, Suite 1100
Rosemont, Illinois 60018
1-847-430-2800
ii 01021076 www.culligan.com
Thank You.................................................................................................................................... 1 Contents
Specifications............................................................................................................................... 2
Introduction.................................................................................................................................. 5
How Your Water Conditioner Works............................................................................................... 6
The Culligan Process..................................................................................................................... 7
Modes of Operation...................................................................................................................... 8
Installation.................................................................................................................................. 10
Programming.............................................................................................................................. 28
Maintenance.............................................................................................................................. 41
Sanitizing Procedure .................................................................................................................. 44
Things to Check Before You Call for Service................................................................................... 45
Error Codes................................................................................................................................ 46
When and How to Bypass Your Water Conditioner........................................................................ 47
Performance Data Sheets
Culligan HE 9" Water Softener with Soft-Minder® Meter............................................................... 48
Culligan HE 9” Water Softener with Aqua-Sensor® Sensing Device................................................ 49
Culligan HE 10” Water Softener with Soft-Minder® Meter............................................................. 50
Culligan HE 10” Water Softener with Aqua-Sensor® Sensing Device.............................................. 51
Culligan HE 12” Water Softener with Soft-Minder® Meter............................................................. 52
Culligan HE 12” Water Softener with Aqua-Sensor® Sensing Device.............................................. 53
Culligan HE 14” Water Softener with Soft-Minder® Meter............................................................. 54
Culligan HE 14” Water Softener with Aqua-Sensor® Sensing Device.............................................. 55
Culligan HE 9” Upflow Water Softener with Soft-Minder® Meter.................................................... 56
Culligan HE 9” Upflow Water Softener with Aqua-Sensor® Sensing Device..................................... 57
Culligan HE 10” Upflow Water Softener with Soft-Minder® Meter.................................................. 58
Culligan HE 10” Upflow Water Softener with Aqua-Sensor® Sensing Device................................... 59
Culligan HE Municipal 9" Water Softener.................................................................................. 60
Culligan HE Municipal 10” Water Softener................................................................................ 61
Culligan HE Municipal 12” Water Softener................................................................................ 62
Culligan HE Municipal 14” Water Softener................................................................................ 63
California Department of Public Health Certificates.......................................................................... 64
Important Data on Your Water Filter.............................................................................................. 68
Electrical Schematic..................................................................................................................... 69
Parts List..................................................................................................................................... 70
Culligan Limited Warranty........................................................................................................... 79
Index......................................................................................................................................... 81
01021076 iii
About this This manual:
Manual • familiarizes the operator with the equipment
• explains installation and setup procedures
• provides basic programming information
• explains the various modes of operation
• gives specifications and troubleshooting information
Safe Practices
Throughout this manual there are paragraphs set off by special headings.
Notice (or Note) is used to emphasize installation, operation or maintenance information which is impor-
tant, but does not present any hazard. For example,
NOTICE The nipple must extend no more than 1 inch above the cover plate.
Caution is used when failure to follow directions could result in damage to equipment or property.
Warning is used to indicate a hazard which could cause injury or death if ignored.
WARNING! Electrical shock hazard! Unplug the unit before removing the
timer mechanism or cover plates!
The CAUTION and WARNING paragraphs are not meant to cover all possible conditions and situa-
tions that may occur. Understand that common sense, caution, and careful attention are conditions which
cannot be built into the equipment. These MUST be supplied by the personnel installing, operating, or
maintaining the system.
Be sure to check and follow the applicable plumbing codes and ordinances when installing this equip-
ment. Local codes may prohibit the discharge of sanitizing or descaling solutions to drain.
Use protective clothing and proper face or eye protection equipment when handling chemicals or tools.
NOTE The Culligan High Efficiency Softener is not intended for use with water that is
microbiologically unsafe or of unknown quality without adequate disinfection
either before or after the system.
NOTE Check with your public works department for applicable local plumbing and
sanitation codes. Follow local codes if they differ from the standards used in
this manual. To ensure proper and efficient operation of the Culligan High
Efficiency Filter to your full satisfaction, carefully follow the instructions in this
manual.
iv 01021076
Welcome To Your New World of Better Living with Culligan Water. Thank You
The Culligan HE Water Softeners with Soft-Minder® Meter and Aqua-Sensor® sens-
ing device are tested and certfied by WQA against NSF/ANSI Standard 372, CSA
B483.1, NSF/ANSI Standard 44 for the effective reduction of hardness (calcium and
magnesium), barium, and radium 226/228, as verified and substantiated by test data.
The Culligan HE Municipal Water Softeners are tested and certified by WQA against
NSF/ANSI Standard 372, CSA B483.1, and NSF/ANSI Standard 44 for the effective
reduction of hardness (calcium and magnesium), and NSF/ANSI Standard 42 for the
effective reduction of Chlorine Taste and Odor, as verified and substantiated by test data.
For installations in Massachusetts, Massachusetts Plumbing Code 248 CMR shall be ad-
hered to. Consult your licensed plumber for installation of this system. This system and
its installation must comply with state and local regulations. The use of saddle valves is
not permitted.
If this is your first experience having soft, conditioned water in your home, you’ll be amazed at the marvel-
ous difference it makes. We promise that you’ll never want to be without it again.
Congratulations, too, on selecting one of the “first family” of water conditioners in the prestigious Culligan
High Efficiency Water Softeners. With Culligan’s many years of knowledge and experience in water treat-
ment, you can be confident that the model you selected has been designed and engineered to provide
years of service with a minimum of care and attention.
Some localities have corrosive water. A water softener cannot correct this problem and so its printed war-
ranty disclaims liability for corrosion of plumbing lines, fixtures or appliances. If you suspect corrosion,
your Culligan Dealer has equipment to control the problem.
NOTICE Sodium Information: Water softeners using sodium chloride for regenera-
tion add sodium to the water. Persons who are on sodium restricted diets
should consider the added sodium as part of their overall sodium intake.
Serial Numbers
The control valve serial number is located on the back of the timer case.
The media tank serial number is located on the top surface of the tank.
01021076 1
Specifications Culligan High Efficiency Water Conditioners with
Aqua-Sensor® Device or Soft-Minder® Meter—Downflow Regeneration
Model 9" Model 10" Model 12" Model 14" Model
Control Valve 1” Reinforced Thermoplastic w/ HE Circuit Boards
Overall Conditioner Ht 56 in 62 in 60 in 73 in
The efficiency rated dosage is only valid at the stated salt dosage and is efficiency rated according to NSF/ANSI Standard 44.
1
Measured from top of media to top surface of tank threads (backwashed and drained).
2
4
Auxiliary flow rates do not represent the maximum service flow rate used for determining the softener’s rated capacity and efficiency and that continuous
operation at these flow rates greater than the maximum service flow rate may affect capacity and efficiency performances.
Backwash at 120 psi.
5
10 minute backwash, 4 lb. 9” model, 6 lb. 10” model, 7 lb. 12” model, or 12 lb. 14” model salt dosage.
6
2 01021076
Culligan High Efficiency Softener—Upflow Regeneration
Model 9" Model 10" Model
Control Valve 1” Reinforced Thermoplastic with HE Circuit Board
Overall Conditioner Height 56 in 62 in
Media Tank Design Quadra-Hull™
16 x 43 in 16 x 43 in
Salt Storage Tank Dimensions (Dia x Ht)
or 18 x 43 in or 18 x 43 in
Exchange Media, Type and Quantity Cullex® Media, 1.0 ft3 Cullex Media, 1.5 ft3
Exchange Capacity @ Salt Dosage Per Recharge 9,792 gr @ 2.0 lb 30,081 gr @ 6.0 lb
Efficiency rated dosage1 4,896 gr/lb @ 2 lb salt dosage 5,014 gr/lb @ 3 lb salt dosage
Proportional Brining Efficiency Rating2 5,250 gr/lb @ 4 lb salt dosage 5,247 gr/lb @ 6 lb salt dosage
Freeboard to Media 3
14.5 in 14.5 in
Freeboard to Underbedding 4
44.5 in 47.5 in
Rated Service Flow @ Pressure Drop 9.0 gpm @ 11 psi 9.4 gpm @ 12 psi
Consumption, Average 7
33 gallons 35 gallons
The efficiency rated dosage is only valid at the stated salt dosage and is efficiency rated according to NSF/ANSI 44.
1
2
The Proportional Brining Efficiency Rating assumes a 20 percent reserve capacity at the time of regeneration that is typical of what the manufacturer expects
under real-world operation. Proportional brining is not measured by NSF/ANSI 44, and so this cliam is not, and can not, be rated to NSF/ANSI 44.
Measured from top of media to top surface of tank threads. (backwashed and drained).
3
5
Auxiliary flow rates do not represent the maximum service flow rate used for determining the softener’s rated capacity and efficiency and that continuous
operation at these flow rates greater than the maximum service flow rate may affect capacity and efficiency performances.
Backwash at 35 psi (830 kPa).
6
01021076 3
Culligan HE Municipal Water Softener
9" Model 10" Model 12" Model 14" Model
Control Valve 1”, 5-cycle Reinforced Thermoplastic with Global Electronic (GBE) Circuit Board
Exchange Media, Type and Cullex® Media, Cullex® Media, Cullex® Media, Cullex® Media,
Quantity 0.8 ft3 1.0 ft3 1.5 ft3 2.3 ft3
6 01021076
Your Culligan water conditioner consists of three basic components, (A) the Control Valve, (B) the Mineral The Culligan
Tank, and (C) the Brine System.
Process
A. Control Valve
The exclusive Culligan control valve automatically A
performs a variety of tasks that are necessary for the
proper operation of your water conditioner. These tasks, B C
commonly referred to as cycles or operating positions,
are Service, Regeneration, and Brine Refill.
1. Service: While the control valve is in the
service cycle, hard water is directed down
through the column of Cullex® resin where
hardness minerals are removed from the
water. The softened water is then directed into
your household plumbing lines. The ability of
the Cullex resin to remove hardness minerals
needs to be periodically replenished; this is
referred to as …
2. Regeneration: While the control valve is in
the regeneration cycle, water is first directed
up through the column of Cullex resin to flush accumulated sediment out of the resin and down
the drain. Then, the regenerant brine solution is slowly drawn from the bottom of the salt storage
tank of the Brine System and is directed down through the column of Cullex resin, restoring the
ability of the resin to remove hardness minerals from your water supply. Once completed, the
regeneration cycle is followed by …
3. Brine Refill: While the control valve is in the brine refill cycle, a predetermined amount of
water is directed to the salt storage tank of the Brine System so that additional salt can be dis-
solved to provide the brine solution that will be needed for the next regeneration cycle.
01021076 7
Modes of Water Meter Mode
Operation In water meter mode, the controller keeps track of the quantity of water that has flowed through the resin
bed. Based on the influent water hardness and the hardness capacity of the resin bed, a service life expec-
tancy in the quantity of softened water is calculated and programmed into the control. When the set point
is reached, regeneration is triggered. If the predict mode is not selected the regeneration will start at time
of regeneration. In immediate mode the regeneration starts as soon as the regeneration signal is provided.
If time clock backup is set and the capacity has not been exhausted but the days since last regen is greater
than time clock backup, setting the softener will immediately regenerate.
Aqua-Sensor® Mode
The Aqua-Sensor is a conductivity probe that senses when the hardness front passes through the resin
bed. It functions independently of the influent water hardness so therefore, is useful in conditions when the
influent water hardness varies throughout the year. It provides for the most efficient mode of operation. In
addition to sensing when a resin bed is exhausted, it can also be used to determine when the brine solu-
tion is rinsed from the resin bed during the Brine Draw/Slow Rinse cycle triggering the control to move to
fast rinse. This patented feature provides water savings by optimizing the amount of rinse water required
to completely rinse out the resin bed.
Modem
The modem allows for the system to be remotely monitored detecting problems before they occur, to sched-
ule salt delivery when it is needed and to keep the system software up to date with the latest advances.
Manual Regeneration
Manual regeneration can be initiated via the softener control valve or wireless remote display. Manual
regeneration can be initiated to begin regeneration immediately or that night. To immediately initiate re-
generation, press and hold for at least ten (10) seconds. To cancel a delayed regeneration, press and
hold for at least five (5) seconds.
Predict Mode
The Predict Mode is used with the flow meter to determine the optimum regeneration point. Before the re-
generation starts, the control will compare the remaining capacity value with the average daily water use.
If the average daily water usage is less than the reserve capacity, the controller will wait 24 more hours
before regeneration. If the reserve capacity is less than the average daily water usage, the control will
initiate regeneration. This works in delay mode only. At any time, if the total capacity value is reached,
the control will initiate an immediate regeneration.
Pre-Rinse Mode
The Pre-rinse mode is used to pre-rinse the softener resin bed or filter media. The pre-rinse in flow meter
mode will occur after the control has sensed that no water has flowed through the control for a period of X
hours (can be set through the programming menu). When the control is in this mode, once the X amount
of hours have elapsed the control will cycle to the fast rinse position for the pre-set length of minutes and
then return to the home or service position.
8 01021076
Down Flow Regeneration
Water and regenerate flow downward through the media tank.
Up Flow Regeneration
Water flow is downward and regenerate flow is upward through the media tank. The significance of this
is that regeneration will be most effective in those parts of the resin bed which are treated with the freshest
regenerate solution. There will tend to be less hardness leakage with up-flow regeneration.
Proportional Brining
The control monitors your softened water usage making only enough brine to regenerate that part of the
resin bed that has been exhausted. In this way the amount of salt used relates directly to the amount of
softened water used, making it more efficient and cost effective. Proportional brining can only be used
with upflow regeneration. The Aqua-Sensor or meter can be used to initiate a regeneration.
Dial-A-Softness®
Dial-A-Softness is a manual adjustment built into the control valve that allows for variable hardness bypass
into the softened water. The hard water bypass can be adjusted from 0% to 30%. The Dial-A-Softness also
increases the softener capacity in proportion to the percent hard water bypass (less salt used).
01021076 9
Installation NOTE Read this section entirely before starting the installation. Follow all applicable
plumbing and electrical codes.
Component Description
The water conditioner is shipped from the factory in a minimum of three cartons. With the exception of
media containers, remove all components from their cartons and inspect them before starting installation.
Media Tank
Includes Quadra-Hull™ media tank complete with Cullex® ion exchange resin, underbedding and outlet
manifold (12” and 14” tanks are shipped without media).
NOTE Check and comply with your state and local codes. You must follow these
guidelines.
Special Tools
• Torch, solder and flux for sweat copper connections
• Use only lead-free solder and flux for all sweat-solder connections as required by state and federal
codes.
• Threading tools, pipe wrenches and thread sealer for threaded connections.
• Saw, solvent and cement for plastic pipe connections.
10 01021076
Materials
• Brine line, 3/8” (PN 01009819 or equivalent)
• Drain line, 1/2” (PN 00303082, gray, semi-flexible; PN 00331946, black, semi-rigid; or
equivalent)
• Thread sealing tape
• Pressure reducing valve (if pressure exceeds 125 psi [860 kPa])
• Pipe and fittings suited to the type of installation
• Water softener salt (rock, solar or pellet salt formulated specifically for water softeners)
Application
Water Quality
Verify that raw water hardness and iron are within limits. Note the hardness for setting the salt dosage
and recharge frequency.
Iron is a common water problem. The chemical/physical nature of iron found in natural water supplies is
exhibited in four general types: Dissolved Iron, Particulate Iron, Organic Bound Iron and Bacterial Iron.
Hardness sample kits are available through your local Culligan dealer.
Pressure
If pressure exceeds 125 psi (860 kPa), install a pressure reducing valve (see materials checklist). On pri-
vate water systems, make sure the minimum pressure (the pressure at which the pump starts) is greater than
20 psi (140 kPa). Adjust the pressure switch if necessary.
CAUTION! The use of a pressure reducing valve may limit the flow of
water in the household.
Temperature
Do not install the unit where it might freeze, or next to a water heater or furnace or in direct sunlight.
Outdoor installation is not recommended, and voids the warranty. Use the Culligan Outdoor HE softener
for outdoor installations. The Culligan Outdoor HE softener has been certified by Underwriter’s Laborato-
ries for outdoor installation. If installing in an outside location, you must take the steps necessary to assure
the softener installation plumbing, wiring, etc. Areas well protected from the elements (sunlight, rain, wind,
heat, cold), contamination, vandalism, etc. as when installed indoors.
Location
Space Requirements
Allow 6–12 inches (15–30 cm) behind the unit for plumbing and drain lines and 4 feet (1.3 meters) above
for service access and filling the salt container.
Floor Surface
Choose an area with solid, level floor free of bumps or irregularities. Bumps, cracks, stones and other ir-
regularities can cause the salt storage tank bottom to crack when filled with salt and water.
01021076 11
Drain Facilities
Choose a nearby drain that can handle the rated drain flow (floor drain, sink or stand pipe). Refer to
“Table 3. Height of Discharge Above Floor Level Operating.” on page 22, for maximum drain line length.
NOTE Most codes require an anti-siphon device or air gap. Observe all local
plumbing codes and drain restrictions. The system and installation must
comply with all state and local laws and regulations.
Electrical Facilities
A 10-foot cord and wall mount plug-in transformer are provided. The customer should provide a recepta-
cle, preferably one not controlled by a switch that can be turned off accidentally. Observe local electrical
codes.
NOTE The softener works on 24 Volt/60 Hz electrical power only. Be sure to use the
included transformer. Be sure the electrical outlet and transformer are in an
inside location to protect from moisture. Properly ground to conform with all
governing codes and ordinances.
NOTE PN 01020620 and PN 01018133 plug-in transformer are rated for indoor
installations only.
Placement
NOTE Read this section entirely before starting the installation. Follow all applicable
plumbing and electrical codes.
Refer to Figure 1 for system placement.
1. With the exception of media containers, open the remaining containers, remove all the compo-
nents, and inspect them before starting installation.
2. Set the media tank on a solid, level surface near water, drain and electrical facilities.
3. Set the brine system on a flat, smooth, solid surface as near the media tank as possible.
Tank Assembly
9” and 10” tanks are filled with media at the factory.
1. Before the unit can be connected to the plumbing, you must insert the manifold and load the
media into the tank for 12” and 14” units.
CAUTION! Do not lay the tank down unless a suitable lifting device
is available. Personal injury and damage to the unit can
result if dropped.
12 01021076
Treated Water Out
To
Hose
Bibs
Drain Line
Hard Water In
Heater
Air Gap
(2x Pipe Diameter Water
or 1 inch, whichever Brine Tank Meter
is larger) or
Pump
6. Load the tank with the Cullex® ion exchange resin. Leveling is not
required.
7. Remove the funnel.
8. Install the inlet strainer making sure to thread the strainer until it
bottoms out on the tank thread. Failure to install the strainer cor-
rectly can cause the control to leak.
3. Moisten the cable sheath and slide the cable grip up or down to
the proper cable length.
4. Tighten the small Aqua-Sensor plug so that the fitting cannot slide
along the cable.
NOTE The media tank must be backwashed so that the Aqua-Sensor probe can
fall into the proper position. See “Recommended Aqua-Sensor® Start-Up
Procedure” on page 40.
NOTE Do not push the top O-ring down to the flange surface on the adapter.
NOTE The larger of the two O-rings in the parts should be positioned between the
adapter and the valve. Do not stretch the smaller O-ring onto the top of the
tank adapter.
3. Lubricate only the top o-ring on the tank adapter and the outlet manifold o-ring with silicone
lubricant.
4. Screw the adapter into the tank until the adapter bottoms out on the tank flange.
NOTE The adapter only needs to be tightened hand-tight to the tank flange.
5. Align the manifold with the center opening in the valve, and firmly press the valve onto the
adapter.
NOTE Make sure to push the valve straight down onto the manifold. If the valve is
cocked, it may cause the O-ring to slip off the manifold.
6. Assemble the tank clamp to the control, and tighten the clamp screw.
14 01021076
NOTE The clamp and valve will be able to rotate on the tank until pressure is
applied.
NOTE For upflow models, the backwash and fast rinse default times are set at five
(5) minutes.
01021076 15
Eductor Nozzle and Throat Replacement
Refer to Figure 6 and the instructions below when changing the eductor nozzle and throat.
1. Remove the eductor cap clip.
2. Remove the eductor cap.
3. Remove the eductor assembly.
4. Remove the eductor screen from the assembly
5. Remove the blue nozzle and replace it with the correct nozzle. See Table 2.
6. Make sure to put the O-ring on the nozzle.
7. Replace the eductor throat if required.
8. Reverse the procedure to reassemble.
NOTE Observe the orientation of the arrow on the eductor cap. The arrow faces
down for downflow regeneration applications; the arrow faces up for
upflow/proportional brining regeneration applications.
Clip
Screen
Nozzle
Throat
Eductor Cap
NOTE The number on the flow control should face into the valve body.
NOTE Do not re-install the cover until the drain line tubing is connected.
16 01021076
A
Figure 7. HE softener cover fastener clip. Figure 8. Removing the HE softener cover.
Filter
Brine Elbow
Clips
Drain Elbow Flow Control
01021076 17
Figure 10. Cover fastener clip. Figure 11. Reattaching the HE softener cover.
Push down
into place
A
Cover
Fastener
18 01021076
Dial-a-Softness
Dial-a-Softness is a manual adjustment built into
the control valve that allows for variable hardness
bypass into the softened water. The hard water
bypass can be adjusted to produce 1–3 gpg
hardness bleed. Shipped from the factory the Dial-
a-Softness knob is set to the “SOFTEST” position
(no hard water bypass). See Figure 13.
To set the Dial-a-Softness:
1. Locate the Dial-a-Softness knob on the
control valve.
2. Set the Dial-a-Softness knob to posi-
Figure 13. Dial-a-Softness knob.
tion A, B, or C as outlined in the table
below, based on raw water hardness; this should produce a 1–3 gpg hardness bleed.
Letter on Dial-a-Softness Knob 1–3 gpg Hardness Bleed
SOFTEST 0
A Greater than 20 gpg
B Between 10–20 gpg
C Less than 10 gpg
NOTE The HE must take into account the adjusted capacity if the Dial-a-Softness was
changed. See Advanced System Setup to update the Dial-a-Softness setting.
Plumbing Connections
Shipped with each softener is a Culligan® bypass valve, which is used to connect the softener to the
plumbing system. The bypass allows the softener to be isolated from the water service line if service is
necessary while still providing water to the home. The bypass valve can be directly plumbed into the
system, or can be connected with the following optional sweat connection kits.
• P/N 01010783 1" Sweat Copper Adapter Kit
• P/N 01016564 3/4" Sweat Copper Adapter Kit
• P/N 01016565 3/4" Elbow Sweat Copper Adapter Kit
• P/N P1018757 1" NPT Plastic Elbow Adapter Kit
• P/N P1018758 1" NPT Plastic Installation Kit
CAUTION! Close the inlet supply line and relieve the system
pressure before cutting into the plumbing! Flooding
could result if not done!
01021076 19
Bypass Valve Installation
Refer to Figure 14 and the instructions below to connect the meter, bypass valve, and interconnecting
pipe.
1. All HE units are equipped with a Soft-Minder® meter. The meter is installed on the outlet side
of the control valve. The meter body fits in the same space as the coupling between the control
valve and the bypass. Make sure the arrow on the flow meter is pointing in the direction of the
flow.
2. The bypass valve connects directly to the control valve with the meter and coupling and two
assembly pins. Lubricate all O-rings on the couplings/meter with silicone lubricant.
Assembly Pin
Brine Connection
Meter Body
Coupling
Bypass
NOTE If the ground from the electrical panel or breaker box to the water meter or
underground copper pipe is tied to the copper water lines and these lines
are cut during installation of the bypass valve, an approved grounding strap
must be used between the two lines that have been cut in order to maintain
continuity. The length of the grounding strap will depend upon the number
of units being installed. In all cases where metal pipe was originally used
and is later interrupted by the bypass valve to maintain proper metallic pipe
bonding, an approved ground clamp c/w not less than #6 copper conductor
must be used for continuity. Check your local electrical code for the correct
clamp and cable size.
To bypass, turn the blue knob clockwise (see directional arrow on end of knob) until the knob stops as
shown. DO NOT OVERTIGHTEN! (Figure 15). To return to service, turn the blue knob counter-clockwise
20 01021076
(see directional arrow on the end of knob) until the knob stops as shown. DO NOT OVERTIGHTEN!
(Figure 16)
About 1-1/4”
Operating
0 ft (0 m) 2 ft (0.6 m) 4 ft (1.2 m) 6 ft (1.8 m) 8 ft (2.4 m) 10 ft (3 m)
Pressure
30 psi (210 kPa) 60 ft (18 m) 50 ft (15 m) 30 ft (9 m) 15 ft (5 m) Not allowable Not allowable
40 psi (279 kPa) 100 ft (30 m) 90 ft (27 m) 70 ft (21 m) 50 ft (15 m) 30 ft (9 m) 12 ft (4 m)
50 psi (349 kPa) 145 ft (41 m) 115 ft (35 m) 80 ft (24 m) 80 ft (24 m) 60 ft (18 m) 40 ft (12 m)
60 psi (419 kPa) 100 ft (30 m) 100 ft (30 m) 85 ft (26 m) 60 ft (18 m)
80 psi (559 kPa) Normal installation should not require 140 ft (43 m) 120 ft (37 m)
100 psi (699 kPa) more than 100 ft (30 m) of drain line 150 ft (46 m)
22 01021076
Brine Valve “A” Dimension
The brine valve contains a brine float which can serve as a backup refill shutoff in the event of a failure,
such as a power outage when in the refill position. The float level should be set based on the salt dosage
setting. Refer to Figure 18.
1. Remove nut retaining brine valve to brine chamber.
2. Lift the brine valve from the brine chamber.
3. Find the correct “A” dimension from Appendix A in the HE Softener Installation/Operation
manual (PN 01021606).
4. Set the distance from the top of the filter screen to the base of the float accordingly. The slight
difference in height when the float is pulled up or down is negligible.
5. Re-install into brine chamber and replace nut.
“A” Dimension
01021076 23
Circuit Board Connections
The 24 Volt power supply and flow meter wire harness is already connected to the circuit board. If no
other circuit board connections are required proceed to the First Time Setup. Refer to the instructions below
and Figure 19 to Figure 22 for connecting the Aqua-Sensor probe wire harness to the circuit board.
CAUTION! Do not touch any surfaces of the circuit board. Electrical static
discharges might cause damage to the board. Handle the
circuit board by holding only the edges of the circuit board.
Mishandling of the circuit board will void the warranty.
1. Remove the electrical enclosure from the control valve. First remove the electrical enclosure
screw and then gently remove the enclosure from the control. Refer to Figure 19 and below
instructions.
Electrical
Enclosure Screw
24 Volt
Power Cord
Flow Meter
Accessories
Wire Harness
NOTE If additional accessories are to be connected to the circuit board (such as the
Smart Brine Tank Probe or a phone line for modem) insert both the Aqua-
Sensor 2.5 Volt power supply wire harness and the Aqua-Sensor sensor
probe wire harness through the third hole on the enclosure.
8. Connect Aqua-Sensor probe wire harness to the circuit board. The Aqua-Sensor probe terminal
is labeled “Aqua-Sensor.” See Figure 22.
NOTE The wire connectors must be connected to the circuit board properly. The wires
must exit the plug-in connector opposite of the raised white base of the circuit
board connector. Failure to properly connect any of the connectors will result
in a malfunction of the circuit board operation.
Support
Bracket
Figure 20. Circuit board power supply. Figure 21. Circuit board removal.
MOTOR CONNECTOR
PHONE
FLOW METER CONNECTOR
2.5v 24v
Blue
Red
White
Black
Aqua-Sensor power
cable should be
plugged to 2.5VAC
connectors—left side
AQUA-SENSOR PROBE
CAUTION! Verify wiring from the terminals to circuit board are correct
before applying power to the control. 24 VAC power must not
be applied to the 2.5 VAC terminals.
Align
circu slot on
it bo fr
ard ame wit
in th h
e en edge o
clos
ure f
Align
circu slot on
it bo fr
ard ame wit
in th h
e en edge o
clos
ure f
01021076 27
Navigating
the Menus
and Keypad
UP button
CHECK MARK
CANCEL (X) button or OK button
DOWN button
NOTE Hold down or to quickly scroll through the setting without repeatedly
pressing the button.
Softening 1. This is the HOME SCREEN. Press any button except to advance
JAN-01-12 12:01P to the MAIN MENU SCREEN.
>1)INFORMATION 2. This is the MAIN MENU SCREEN. The “>” symbol indicates the
2)MANUAL MODE menu selection. Press or to scroll through the menu.
28 01021076
1)INFORMATION 3. This is the MAIN MENU SCREEN. The “>” symbol indicates the
>2)MANUAL MODE menu selection. Press or to scroll through the menu.
MANUAL MODE 5. The screen displays the setting (Manual Mode) and the current value
REGEN NOW (Regen Now). Press to change the value.
6. The screen displays the “>” symbol next to the value, indicating that
MANUAL MODE
>REGEN NOW the value may be changed. Press or to change the value. For
example, press to change the value to REGEN TONITE. Press
again to select the next available value, BYPASS.
MANUAL MODE 7. Press to cancel the changed setting and revert to the default set-
REGEN NOW ting. The screen displays the default setting.
MANUAL MODE 8. Press to accept the changed value. If the setting values are dis-
>BYPASS played, the “>” symbol no longer appears next to the value.
1)INFORMATION 9. The screen then returns to the MAIN MENU. Press to return to
>2)MANUAL MODE the HOME SCREEN.
Softening
10. The screen displays the HOME SCREEN.
JAN-01-12 12:01P
NOTE Unplugging the Culligan HE water softener will not affect any of the control
settings (the control must be plugged in for at least 10 minutes). Once
programmed, the settings will be stored indefinitely.
01021076 29
First Time First Time Setup Procedure
Setup When a new controller is first powered on, the screen will display the first time setup message. The HE
Controller is designed to simplify the setup and installation process by making some default recommenda-
tions during the initial setup. These default settings are appropriate for most common installations.
After completing the plumbing connections to the water softener, turn on and program the HE Controller.
FIRST TIME SETUP When a new controller is first turned on, the screen displays FIRST TIME
PRESS DOWN ARROW SETUP. Press to display the first setup screen.
Serial Number
S/N: 00000123 The screen displays the serial number for this Smart Controller. Press
to display the firmware version information screen.
Firmware Version
FWR216LT21 The screen displays the firmware version and date installed for this Smart
Jan 4 2012 Controller. Press to display the month setup screen.
SET MONTH The screen displays the month setting. Press to accept the information
JAN displayed (and view the next setting), or press to change the setting.
SET MONTH If you press the screen displays a cursor (>) symbol next to the dis-
>JAN played value. Press to see the next available value.
SET MONTH The screen displays February instead of January. Press to accept the
>FEB selected month and advance to the next setting, SET DAY.
The screen displays the day setting. Press to accept the information
SET DAY
displayed (and view the next setup screen), or press to change the
>3 setting.
Press to see the next available value. Press to accept the selected
day and advance to the next setting, SET YEAR.
30 01021076
Set Year (2009–2030)
SET YEAR The screen displays the year setting. Press to accept the information
>2012 displayed (and view the next setup screen), or press to change the
setting.
Press to see the next available value. Press to accept the selected
year and advance to the next setting, CLOCK TYPE.
The screen displays the clock type setting. Press to accept the informa-
CLOCK TYPE
tion displayed (and view the next setup screen), or press to change
>12 HR the setting.
SET HOUR The screen displays the hour setting. Press to accept the information
>12AM displayed (and view the next setup screen), or press to change the
setting.
Press to change the hour (in this example, from 12PM to 10AM).
Press to accept the selected hour and advance to the next setting, SET
MINUTES.
The screen displays the minutes setting. Press to accept the informa-
SET MINUTES tion displayed (and view the next setup screen), or press to change
>01 the setting.
Press to change the minutes (in this example, from 0 to 20). Press
to accept the selected hour and advance to the next setting, UNIT TYPE.
Unit Type (Softener, Filter, or Resin + Carbon)
UNIT TYPE The screen displays the unit type setting. Press to accept the default
>SOFTENER setting (softener) and advance to the next setting, VALVE TYPE.
Valve Type (HE 1, HE 1.25, HE 1.5, HE 1 Twin, HE 1.5 Twin, 4-Cycle, 5-Cycle, or Plat Plus)
The screen displays the valve type setting. Press to accept the default
VALVE TYPE setting (HE 1) and advance to the next setting, UNITS.
>
UNITS The screen displays the units of measure setting. Press to accept the
>US default setting (US) and advance to the next setting, INSTALL TYPE.
01021076 31
Install Type (Residential or Commercial)
INSTALL TYPE The screen displays the installation type setting. Keep this at the default,
>Residential Residential. Press to view the next setting, BRINING TYPE.
BRINING TYPE The screen displays the brining type setting. Press or and
>Downflow then to change this setting to Downflow and view the next setting,
TANK DIAMETER.
Tank Diameter (10, 12, 14)
TANK DIAMETER The screen displays the tank diameter setting. Press or
>10 and then to change the value and view the next setting, WATER
HARDNESS.
Water Hardness (1–170)
HARDNESS GPG The screen displays the water hardness setting in grains per gallon. Press
25 (1109 GAL) or and then to change the value and begin initialization.
The screen displays the current state (the display alternates between Soft-
Softening
ening and any error) and the date/time set for the unit. This is the default
JAN-01-12 12:01P home screen.
The controller is designed to simplify the setup and installation process by making some default recom-
mendations during the Initial Setup. The default settings are designed to be appropriate for most common
installations.
32 01021076
Follow this procedure to update the date or time. Set Date and
NOTE The control must be returned to the HOME screen if settings are changed. Time
SOFTENING
N/A 1. From the HOME screen, press to view the main menu.
JAN-01-12 12:01P
Set Day
Set Year
SET YEAR 2009– 5. The screen displays the year setting. Press or
>2012 2030 and then to change the setting.
CLOCK TYPE 12 HR, 6. The screen displays the clock type setting. Press
> 12 HR 24 HR or and then to change the setting.
Set Hour
12PM–
SET HOUR 11AM, 7. The screen displays the hour setting. Press or
> 12PM and then to change the setting.
0–23
Set Minutes
01021076 33
Screen Display Range Setting Description
DAYLIGHT SAVING Yes, 9. The screen displays the Daylight Savings Time setting.
YES No Press or and then to change the setting.
2)MANUAL MODE 10. The screen displays the main menu. Press to save the
>3)SET DATE/TIME changes and initialize the system.
34 01021076
The following information can be displayed at the control valve or remote display. These settings are read- Information
only. Press or to scroll through the settings. Press to view the previous setting.
SOFTENING
N/A 1. From the HOME screen, press to view the main menu.
JAN-01-12 12:01P
AVERAGE DAILY 0–no 8. The screen displays average water usage for this con-
300 GAL limit figuration. Press to see the next information screen.
01021076 35
Screen Display Range Setting Description
10. The screen the total water used for this configuration.
TOTAL WATER USED 0–no Whole numbers are displayed above 100 gallons.
1000 GAL limit
Press to see the next information screen.
>1)INFORMATION 12. The screen displays the main menu. Press to exit to the
2)MANUAL MODE home screen.
36 01021076
There are several conditions that will cause the control to trip a regeneration. The screen displays REGEN Regeneration
Tonite when the control has signaled for a regeneration. Regenerating is displayed while the control is in
regeneration. The following are conditions that will call for regeneration:
1. When the Soft-Minder® meter has recorded the passage of a predetermined number of gallons.
2. When the Aqua-Sensor® Probe senses the hardness in the Cullex Media.
3. At the preset time, when the number of days without a regeneration is equal to the regeneration
interval (timeclock backup) setting.
4. At the preset time, when Regen Tonite is selected. The screen displays Regen Tonite.
5. Immediately, when the Regen Now is selected. The screen displays Regenerating.
6. Immediately, if power to the unit has been off for more than three hours and the time of day has
been restored.
7. At the preset time based on “Day-of-Week” Regeneration setting.
Follow either procedure to bypass the softener or to initiate a manual regeneration or automatically by-
pass the softener at the control valve or the remote display.
Delayed Regeneration
SOFTENING N/A 1. From the HOME screen, press and hold for at least
JAN-01-12 12:01P three (3)seconds and then release the button.
Immediate Regeneration
SOFTENING N/A 1. From the HOME screen, press and hold for at least
JAN-01-12 12:01P ten (10) seconds.
SOFTENING N/A 1. From the HOME screen, press to view the main
JAN-01-12 12:01P menu.
1)INFORMATION 1–6 2. The screen displays the main menu. Press to se-
>2)MANUAL MODE lect 2)MANUAL MODE.
Off, 30,
60, 90, 4. The screen displays the manual bypass duration, in min-
MANUAL BYPASS utes. This specifies the total time the softener is to be in
120,
OFF 180, the bypass state. Press or and then to
Manual change the setting.
Bypass
38 01021076
Recommended Meter Start-Up Procedure Final Startup
1. Close the main water supply valve.
2. Set the Cul-Flo-Valv® to the bypass position.
3. Ensure that all faucets at the installation site are closed.
4. Direct the drain line discharge into a bucket where flow can be observed.
5. Plug the transformer into a 120 Volt, 60 Hz, single-phase receptacle. The screen displays FIRST
TIME SETUP.
6. Complete the First Time Setup.
7. Open the main supply valve.
8. Initiate an immediate regeneration to move the control into the BACKWASH position.
9. Refer to the section on manual cycling for information on cycling the control through its posi-
tions.
10. When in the BACKWASH position, slowly rotate the bypass to the soft water position until
water flows.
11. Allow the tank to fill slowly until water flows from the drain line.
12. When flow to drain is established, open the bypass fully. Watch the drain line discharge for
signs of resin. If signs of resin particles appear, reduce the flow. Increase the flow again when
resin no longer appears in the discharge.
13. After the BACKWASH runs clear, step the control to the REFILL position to fill the brine tank
and purge air from the brine line.
14. Complete the installation and cleanup.
15. Sanitize the unit as you leave the installation site. See “Sanitizing Procedure” on page 44.
16. Initiate an immediate regeneration, or set to regenerate at the preset time.
01021076 39
Recommended Aqua-Sensor® Start-Up Procedure
NOTE You might find it useful to pre-test the sensor probe in your shop. The same
test setup can be used in the field.
1. Close the main water supply valve.
2. Install the sensor probe into the tank but do not connect the sensor to the control at this time.
3. Set the Cul-Flo-Valv® to the BYPASS position.
4. Ensure that all faucets at the installation site are closed.
5. Direct the drain line discharge into a bucket where flow can be observed.
6. Plug the transformer into a 120 Volt, 60 Hz, single-phase receptacle (make sure to connect both
24V and 2.5V properly).
7. Complete the FIrst Time Set-up.
8. Open the main supply valve.
9. Initiate an immediate regeneration to move the control into the BACKWASH position.
10. Refer to the section on manual cycling for information on cycling the control through its posi-
tions.
11. When in the BACKWASH position, slowly rotate the bypass to the soft water position until
water flows.
12. Continue BACKWASH until the drain effluent is clear and the Aqua-Sensor probe is placed in
the resin bed—at least 10 minutes (use a white foam coffee cup to occasionally collect a sample
of backwash water; the stark white of the cup will show the presence of color throw and resin
fines).
13. Continue or repeat the BACKWASH cycle if needed.
14. After the backwash water runs clear, step the control to the REFILL position to fill the brine tank
and purge air from the brine line.
15. Unplug the control and connect the sensor to the circuit board.
16. Reconnect the power and INSTALL the Aqua-Sensor Probe (Main Menu/ Accessories/
AquaSensor)
17. Check the condition of the Aqua-Sensor (Main Menu/ Diagnostics/ Checksensors)
18. Press the Program key and program the control to the desired settings.
19. Complete installation and cleanup.
20. Sanitize the unit as you leave the installation (see “Sanitizing Procedure” on page 44).
21. Initiate an immediate regeneration.
The thorough backwashing process should have cleared the fines and color-throw from the tank. The
probe should settle into the resin bed during the first couple of minutes of backwashing.
40 01021076
Salt is the mineral used to “recharge” your water conditioner. A brine solution is automatically made up in Salt Supply,
the bottom of the salt storage container, the Cullex® resin beads in the mineral tank are flushed with the
brine solution as a step in the recharging process. Usage and
Service
Your Culligan Water Conditioner has been carefully designed to get the greatest amount of softening
capacity from the salt it uses. Here is some pertinent information about salt usage, types and service.
Salt Economizer
This control is set at the time of installation, and determines salt usage according to the water hardness,
number of persons in the household, and water usage.
NOTICE Sodium Information: Water softeners using sodium chloride for regenera-
tion add sodium to the water. Persons who are on sodium restricted diets
should consider the added sodium as part of their overall sodium intake.
01021076 41
Care and Following these simple precautions will help assure continued trouble-free service and keep your Culligan
Water Conditioner looking like new for years.
Cleaning of
Your Water 1. Do not place heavy objects on top of the salt storage tank or timer cover.
Conditioner 2. Use only mild soap and warm water when cleaning the exterior of the conditioner. Never use
harsh, abrasive cleaning compounds or those which contain acid, such as vinegar, bleach and
similar products.
3. Important: Protect your water conditioner and the entire drainline from freezing temperatures.
4. Important: Culligan water softeners are sold for use on potable water only. If at any time the
water becomes contaminated, such as during a “boil water” advisory, the operation of the
water softener should be discontinued until it is verified that the water is again potable. To do
this, turn the blue knob in a clockwise position, then call your Culligan dealer to have your sys-
tem sanitized before it is placed back into service.
5. Should service, adjustment or trouble-shooting information be needed which is not covered in
the Use and Care Guide, call your Culligan Dealer.
For parts and service availability please call your local independently operated Culligan dealer. For your
nearest Culligan dealer, call (800) 285-5442.
42 01021076
A periodic clean-out of the Salt Storage Tank is necessary to keep your Culligan Water Conditioner at Cleaning
peak operating efficiency. Do it at least every two years when the salt supply is low. Follow these step-by-
step procedures:
Out the Salt
Storage Tank
Tools Needed
• Scoop
• Clean, bucket-size container
• Garden hose
• Household scrub brush or sponge
Procedure
1. Remove the salt storage tank cover and the cap from the brine valve chamber.
2. Lift the brine valve out of the brine valve chamber and set aside in an upright position.
3. If you’d like to save any clean, dry salt remaining in the tank, remove it and place it in a clean
container.
4. Using the scoop, dig out and discard as much remaining salt, water and debris as possible.
5. Remove the brine valve chamber by removing the screws on either side of the salt tank.
6. Remove the salt plate at the bottom of the brine tank.
7. Lay the salt tank on its side and direct a brisk stream of water from your garden hose to its
inside to rinse out all residue.
8. Using a household scrub brush and a mild soapy solution, clean the salt plate. This will com-
plete the tank cleaning.
9. Insert the brine valve into the chamber and replace brine valve chamber cap.
10. Fill the salt storage tank with 4 to 6 inches of water.
11. Fill the tank with salt to within a few inches of the top.
12. Replace salt storage tank cover.
01021076 43
Sanitizing A water softener in daily use on a potable water supply generally requires no special attention other than
keeping the salt tank filled. Occasionally, however, a unit may require sanitization under one of the fol-
Procedure lowing conditions:
• At start-up time.
• After standing idle for a week or more.
• On private supplies, the appearance of off-tastes and odors, particularly if musty or “rotten egg”
(caused by harmless sulfate-reducing bacteria).
NOTE If the water supply contains iron, regenerate the softener before sanitizing to
remove iron from the resin.
44 01021076
If you unexpectedly experience changes in your water, make these simple checks before calling your Cul- Things to
ligan dealer. One of the following conditions may be the reason for your interruption of service.
Check Before
Important You Call for
If any of the following conditions is found, the water softener should be manually regenerated according Service
to instructions on page 37 after you have corrected the problem.
Power Supply
Check your power supply cord. Is it plugged fully into the electric outlet? Be certain that the outlet is not
controlled by a wall switch which has been turned off. Plug in the transformer then reset conditioner to the
correct time of day.
Blown Fuse
Check the house fuse or circuit breaker panel. Replace a blown-out fuse or reset an open circuit breaker.
Power Failure
Any interruption in your power supply or time change—such as daylight savings—will disrupt your soft-
ener’s regeneration schedule by causing the timer to run off-schedule. Reset the timer to the correct time of
day.
Bypass Valves
Check to see if they are in the proper position. Cul-Flo-Valv® Bypass, if used, should be in the “Service”
position (see page 47). If hand valves are used, see that inlet and outlet valve are opened and that the
bypass valve is closed.
No Water
If you aren’t getting any water flow at all, make sure your water supply is working. Open a tap ahead of
the conditioner (outside tap) to see if you have any water pressure. If you have water pressure, check the
bypass valve. If it is in the Service position, put it into the bypass and call your Culligan dealer for service.
Increased Usage
Guests, family additions, new water-using appliances, etc., will result in more water usage and will require
more capacity from your softener. You can reprogram your regeneration schedule by following the direc-
tions beginning on page 37. Call your Culligan dealer for advice and save a service call.
01021076 45
Error Codes The controller display, as well as the Remote Display (if connected), may display the following errors.
REPLACE FILTER
MEDIA 2. Press to display any additional errors present.
Brine Overfill Contact your Culligan dealer. Contact your Culligan dealer.
Failed to refill brine tank. Refill restrictor plugged. Clean or replace refill restrictor. Verify all tubing connec-
No Brine In Tank
Air in brine line causes float to slam shut. tions are properly assembled.
An Aqua-Sensor was “Installed” but main board
Aqua Sens Probe Check connection of Aqua-Sensor to the main board.
46 01021076 detects the Aqua-Sensor is not connected.
Normally, all water except outside lines passes through the water softener. There are times when the water When and
softener should be bypassed, using the Cul-Flo-Valv® Bypass, or a three-way bypass valve. You should
bypass:
How to
Bypass
1. If lines to outside faucets do not bypass the water softener, and you do not want to waste soft-
ened water on lawn sprinkling or other outside uses. Your Water
2. If you are going away on vacation and do not want the unit to recharge.
Conditioner
Bypass Valve
In the back of Culligan water softener is a Cul-Flo-Valv® Bypass valve. To bypass the unit, turn the blue
knob clockwise. To return to softened water service, turn the blue knob counter-clockwise.
Bypassed
To BYPASS, turn the blue knob clockwise (see directional arrow on end of knob) until the knob stops as
shown in Figure 1. DO NOT OVERTIGHTEN!
About 1-1/4”
Softened Water
To return to SERVICE, turn the blue knob counter-clockwise (see directional arrow on end of knob) until the
knob stops as shown in Figure 2. DO NOT OVERTIGHTEN! 01021076 47
Performance Culligan knows the more informed you are about your water treatment systems, the more confident you will be about
its performance. It’s because of this and more than seventy years of commitment to customer satisfaction that Culligan is
Data Sheet providing this Performance Data Sheet to its customers.
NOTICE Read this Performance Data Sheet and compare the capabilities of this unit with your actual
water treatment needs. It is recommended that before purchasing a water treatment unit, you
Culligan High
have your water supply tested to determine your actual water treatment needs.
Efficiency 9” Water
Softener with Soft- Manufacturer: Culligan International Company
9399 W. Higgins Rd., Suite 1100, Rosemont, IL 60018 USA
Minder® Meter
(847) 430-2800
Product: Culligan High Efficiency 9” Water Softener with Soft-Minder® Meter
Softener Specifications:
Service Flow Rate: 9.0 gpm Pressure Drop at Max. Flow Rate: 11 psi
Operating Temp. Range: 33-125°F (0.6–51.7°C) Max. Drain Flow Rate: 2.5 gpm
Working Press. Range: 20–120 psi (1.4–8.5 kg/cm2) Oper. Press. Range (Canada): 20–90 psi (1.4–6.3 kg/cm2)
USEPA Max.
Name of Substance Contaminant Level pH Flow Rate Pressure
Barium 2.0 mg/L 7.5 + 0.5 9.0 gpm 11 (psig)
Radium 226/228 5 pCi/L 7.5 + 0.5 9.0 gpm 11 (psig)
This system is certified for barium and radium 226/228 reduction based on hardness reduction. It is recommended
you test your water every 6 months to ensure the system is performing properly and that hardness, and therefore barium
and radium 226/228, are being reduced. Hardness test strips have been included. Additional strips are available
from your local Culligan dealer.
The Culligan High Efficiency Series 9” Water Softeners with Soft-Minder® Meter are tested and certified by WQA
against NSF/ANSI Standard 372, CSA B483.1, NSF/ANSI Standard 44 for the effective reduction of hardness (cal-
cium and magnesium), barium, and radium 226/228, as verified and substantiated by test data.
An efficiency rated water softener is a DIR softener which also complies with specific performance specifications
intended to minimize the amount of regenerant brine and water used in its operation. Efficiency rated water softeners
shall have a rated salt efficiency of not less than 3350 grains of total hardness exchange per pound of salt (based on
NaCl equivalency) (477 grams of total hardness exchange per kilogram of salt), and shall not deliver more salt than
its listed rating. The efficiency is measured by a laboratory test described in NSF/ANSI 44. The test represents the
maximum possible efficiency the system can achieve. Operational efficiency is the actual efficiency achieved after the
system has been installed. It is typically less than the efficiency due to individual application factors including water
hardness, water usage, and other contaminants that reduce the softener’s capacity.
Refer to the Specifications, Familiarization and Warranty section of this Owner’s Guide for more specific product
information. To avoid contamination from improper handling and installation, your system should only be installed and
serviced by your Culligan Man. Performance will vary based on local water conditions. The substances reduced by this
system are not necessarily in your water.
Culligan water softeners are designed to work with any salt of good quality, although it is recommended that you ask
your local Culligan Man for his suggestion on the best type and grade of salt to use in this softener.
NOTICE This softener is not intended to be used for treating water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the system.
The efficiency rated dosage is only valid at the 4lb. salt dosage and maxmum service flow rate for 9” models.
†
48 01021076
Culligan knows the more informed you are about your water treatment systems, the more confident you will be about
its performance. It’s because of this and more than seventy years of commitment to customer satisfaction that Culligan is
Performance
providing this Performance Data Sheet to its customers. Data Sheet
NOTICE Read this Performance Data Sheet and compare the capabilities of this unit with your actual
water treatment needs. It is recommended that before purchasing a water treatment unit, you
have your water supply tested to determine your actual water treatment needs. Culligan High
Efficiency 9" Water
Manufacturer: Culligan International Company
9399 W. Higgins Rd., Suite 1100, Rosemont, IL 60018 USA
Softener with
(847) 430-2800 Aqua-Sensor®
Sensing Device
Product: Culligan High Efficiency 9” Water Softener with Aqua-Sensor® Sensing Device
Softener Specifications:
Service Flow Rate: 9.0 gpm Pressure Drop at Max. Flow Rate: 11 psi
Operating Temp. Range: 33-125°F (0.6–51.7°C) Max. Drain Flow Rate: 2.5 gpm
Working Press. Range: 20–120 psi (1.4–8.5 kg/cm2) Oper. Press. Range (Canada): 20–90 psi (1.4–6.3 kg/cm2)
USEPA Max.
Name of Substance Contaminant Level pH Flow Rate Pressure
Barium 2.0 mg/L 7.5 + 0.5 9.0 gpm 11 (psig)
Radium 226/228 5 pCi/L 7.5 + 0.5 9.0 gpm 11 (psig)
This system is certified for barium and radium 226/228 reduction based on hardness reduction. It is recommended
you test your water every 6 months to ensure the system is performing properly and that hardness, and therefore barium
and radium 226/228, are being reduced. Hardness test strips have been included. Additional strips are available
from your local Culligan dealer.
The Culligan High Efficiency 9” Water Softeners with Aqua-Sensor® Sensing Device are tested and certified by WQA
against NSF/ANSI Standard 372, CSA B483.1, NSF/ANSI Standard 44 for the effective reduction of hardness (cal-
cium and magnesium), barium, and radium 226/228, as verified and substantiated by test data.
An efficiency rated water softener is a DIR softener which also complies with specific performance specifications
intended to minimize the amount of regenerant brine and water used in its operation. Efficiency rated water softeners
shall have a rated salt efficiency of not less than 3350 grains of total hardness exchange per pound of salt (based on
NaCl equivalency) (477 grams of total hardness exchange per kilogram of salt), and shall not deliver more salt than
its listed rating. The efficiency is measured by a laboratory test described in NSF/ANSI 44. The test represents the
maximum possible efficiency the system can achieve. Operational efficiency is the actual efficiency achieved after the
system has been installed. It is typically less than the efficiency due to individual application factors including water
hardness, water usage, and other contaminants that reduce the softener’s capacity.
Refer to the Specifications, Familiarization and Warranty section of this Owner’s Guide for more specific product
information. To avoid contamination from improper handling and installation, your system should only be installed and
serviced by your Culligan Man. Performance will vary based on local water conditions. The substances reduced by this
system are not necessarily in your water.
Culligan water softeners are designed to work with any salt of good quality, although it is recommended that you ask
your local Culligan Man for his suggestion on the best type and grade of salt to use in this softener.
NOTICE This softener is not intended to be used for treating water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the system.
The efficiency rated dosage is only valid at the 4lb. salt dosage and maxmum service flow rate for 9” models.
†
01021076 49
Performance Culligan knows the more informed you are about your water treatment systems, the more confident you will be about
its performance. It’s because of this and more than seventy years of commitment to customer satisfaction that Culligan is
Data Sheet providing this Performance Data Sheet to its customers.
NOTICE Read this Performance Data Sheet and compare the capabilities of this unit with your actual
Culligan High water treatment needs. It is recommended that before purchasing a water treatment unit, you
have your water supply tested to determine your actual water treatment needs.
Efficiency 10"
Water Softener Manufacturer: Culligan International Company
with Soft-Minder® 9399 W. Higgins Rd., Suite 1100, Rosemont, IL 60018 USA
(847) 430-2800
Meter
Product: Culligan High Efficiency 10” Water Softener with Soft-Minder® Meter
Softener Specifications:
Service Flow Rate: 9.4 gpm Pressure Drop at Max. Flow Rate: 12 psi
Operating Temp. Range: 33-125°F (0.6–51.7°C) Max. Drain Flow Rate: 2.0 gpm
Working Press. Range: 20–120 psi (1.4–8.5 kg/cm2) Oper. Press. Range (Canada): 20–90 psi (1.4–6.3 kg/cm2)
USEPA Max.
Name of Substance Contaminant Level pH Flow Rate Pressure
Barium 2.0 mg/L 7.5 + 0.5 9.4 gpm 12 (psig)
Radium 226/228 5 pCi/L 7.5 + 0.5 9.4 gpm 12 (psig)
This system is certified for barium and radium 226/228 reduction based on hardness reduction. It is recommended
you test your water every 6 months to ensure the system is performing properly and that hardness, and therefore barium
and radium 226/228, are being reduced. Hardness test strips have been included. Additional strips are available
from your local Culligan dealer.
The Culligan High Efficiency Series 10" Water Softeners with Soft-Minder® Meter are tested and certified by WQA
against NSF/ANSI Standard 372, CSA B483.1, NSF/ANSI Standard 44 for the effective reduction of hardness (cal-
cium and magnesium), barium, and radium 226/228, as verified and substantiated by test data.
An efficiency rated water softener is a DIR softener which also complies with specific performance specifications
intended to minimize the amount of regenerant brine and water used in its operation. Efficiency rated water softeners
shall have a rated salt efficiency of not less than 3350 grains of total hardness exchange per pound of salt (based on
NaCl equivalency) (477 grams of total hardness exchange per kilogram of salt), and shall not deliver more salt than
its listed rating. The efficiency is measured by a laboratory test described in NSF/ANSI 44. The test represents the
maximum possible efficiency the system can achieve. Operational efficiency is the actual efficiency achieved after the
system has been installed. It is typically less than the efficiency due to individual application factors including water
hardness, water usage, and other contaminants that reduce the softener’s capacity.
Refer to the Specifications, Familiarization and Warranty section of this Owner’s Guide for more specific product
information. To avoid contamination from improper handling and installation, your system should only be installed and
serviced by your Culligan Man. Performance will vary based on local water conditions. The substances reduced by this
system are not necessarily in your water.
Culligan water softeners are designed to work with any salt of good quality, although it is recommended that you ask
your local Culligan Man for his suggestion on the best type and grade of salt to use in this softener.
NOTICE This softener is not intended to be used for treating water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the system.
The efficiency rated dosage is only valid at the 6 lb. salt dosage and maxmum service flow rate for 10” models.
†
50 01021076
Culligan knows the more informed you are about your water treatment systems, the more confident you will be about
its performance. It’s because of this and more than seventy years of commitment to customer satisfaction that Culligan is
Performance
providing this Performance Data Sheet to its customers. Data Sheet
NOTICE Read this Performance Data Sheet and compare the capabilities of this unit with your actual
water treatment needs. It is recommended that before purchasing a water treatment unit, you
have your water supply tested to determine your actual water treatment needs. Culligan High
Efficiency 10"
Manufacturer: Culligan International Company
9399 W. Higgins Rd., Suite 1100, Rosemont, IL 60018 USA
Water Softener
(847) 430-2800 with Aqua-Sensor®
Sensing Device
Product: Culligan High Efficiency 10” Water Softener with Aqua-Sensor® Sensing Device
Softener Specifications:
Service Flow Rate: 9.4 gpm Pressure Drop at Max. Flow Rate: 12 psi
Operating Temp. Range: 33-125°F (0.6–51.7°C) Max. Drain Flow Rate: 2.0 gpm
Working Press. Range: 20–120 psi (1.4–8.5 kg/cm2) Oper. Press. Range (Canada): 20–90 psi (1.4–6.3 kg/cm2)
USEPA Max.
Name of Substance Contaminant Level pH Flow Rate Pressure
Barium 2.0 mg/L 7.5 + 0.5 9.4 gpm 12 (psig)
Radium 226/228 5 pCi/L 7.5 + 0.5 9.4 gpm 12 (psig)
This system is certified for barium and radium 226/228 reduction based on hardness reduction. It is recommended
you test your water every 6 months to ensure the system is performing properly and that hardness, and therefore barium
and radium 226/228, are being reduced. Hardness test strips have been included. Additional strips are available
from your local Culligan dealer.
The Culligan High Efficiency 10” Water Softeners with Aqua-Sensor® Sensing Device are tested and certified by WQA
against NSF/ANSI Standard 372, CSA B483.1, NSF/ANSI Standard 44 for the effective reduction of hardness (cal-
cium and magnesium), barium, and radium 226/228, as verified and substantiated by test data.
An efficiency rated water softener is a DIR softener which also complies with specific performance specifications
intended to minimize the amount of regenerant brine and water used in its operation. Efficiency rated water softeners
shall have a rated salt efficiency of not less than 3350 grains of total hardness exchange per pound of salt (based on
NaCl equivalency) (477 grams of total hardness exchange per kilogram of salt), and shall not deliver more salt than
its listed rating. The efficiency is measured by a laboratory test described in NSF/ANSI 44. The test represents the
maximum possible efficiency the system can achieve. Operational efficiency is the actual efficiency achieved after the
system has been installed. It is typically less than the efficiency due to individual application factors including water
hardness, water usage, and other contaminants that reduce the softener’s capacity.
Refer to the Specifications, Familiarization and Warranty section of this Owner’s Guide for more specific product
information. To avoid contamination from improper handling and installation, your system should only be installed and
serviced by your Culligan Man. Performance will vary based on local water conditions. The substances reduced by this
system are not necessarily in your water.
Culligan water softeners are designed to work with any salt of good quality, although it is recommended that you ask
your local Culligan Man for his suggestion on the best type and grade of salt to use in this softener.
NOTICE This softener is not intended to be used for treating water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the system.
The efficiency rated dosage is only valid at the 6lb. salt dosage and maxmum service flow rate for 10” models.
†
01021076 51
Performance Culligan knows the more informed you are about your water treatment systems, the more confident you will be about
its performance. It’s because of this and more than seventy years of commitment to customer satisfaction that Culligan is
Data Sheet providing this Performance Data Sheet to its customers.
NOTICE Read this Performance Data Sheet and compare the capabilities of this unit with your actual
Culligan High water treatment needs. It is recommended that before purchasing a water treatment unit, you
have your water supply tested to determine your actual water treatment needs.
Efficiency 12"
Water Softener Manufacturer: Culligan International Company
9399 W. Higgins Rd., Suite 1100, Rosemont, IL 60018 USA
with Soft-Minder®
(847) 430-2800
Meter
Product: Culligan High Efficiency 12” Water Softener with Soft-Minder® Meter
Softener Specifications:
Service Flow Rate: 10.0 gpm Pressure Drop at Max. Flow Rate: 10 psi (71 kPa)
Operating Temp. Range: 33-125°F (0.6–51.7°C) Max. Drain Flow Rate: 3.0 gpm
Working Press. Range: 20–120 psi (1.4–8.5 kg/cm2) Oper. Press. Range (Canada): 20–90 psi (1.4–6.3 kg/cm2)
USEPA Max.
Name of Substance Contaminant Level pH Flow Rate Pressure
Barium 2.0 mg/L 7.5 + 0.5 10.0 gpm 10 (psig)
Radium 226/228 5 pCi/L 7.5 + 0.5 10.0 gpm 10 (psig)
This system is certified for barium and radium 226/228 reduction based on hardness reduction. It is recommended
you test your water every 6 months to ensure the system is performing properly and that hardness, and therefore barium
and radium 226/228, are being reduced. Hardness test strips have been included. Additional strips are available
from your local Culligan dealer.
The Culligan High Efficiency Series 12” Water Softeners with Soft-Minder® Meter are tested and certified by WQA
against NSF/ANSI Standard 372, CSA B483.1, NSF/ANSI Standard 44 for the effective reduction of hardness (cal-
cium and magnesium), barium, and radium 226/228, as verified and substantiated by test data.
An efficiency rated water softener is a DIR softener which also complies with specific performance specifications
intended to minimize the amount of regenerant brine and water used in its operation. Efficiency rated water softeners
shall have a rated salt efficiency of not less than 3350 grains of total hardness exchange per pound of salt (based on
NaCl equivalency) (477 grams of total hardness exchange per kilogram of salt), and shall not deliver more salt than
its listed rating. The efficiency is measured by a laboratory test described in NSF/ANSI 44. The test represents the
maximum possible efficiency the system can achieve. Operational efficiency is the actual efficiency achieved after the
system has been installed. It is typically less than the efficiency due to individual application factors including water
hardness, water usage, and other contaminants that reduce the softener’s capacity.
Refer to the Specifications, Familiarization and Warranty section of this Owner’s Guide for more specific product
information. To avoid contamination from improper handling and installation, your system should only be installed and
serviced by your Culligan Man. Performance will vary based on local water conditions. The substances reduced by this
system are not necessarily in your water.
Culligan water softeners are designed to work with any salt of good quality, although it is recommended that you ask
your local Culligan Man for his suggestion on the best type and grade of salt to use in this softener.
NOTICE This softener is not intended to be used for treating water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the system.
The efficiency rated dosage is only valid at the 8 lb. salt dosage and maxmum service flow rate for 12” models.
†
52 01021076
Culligan knows the more informed you are about your water treatment systems, the more confident you will be about Performance
its performance. It’s because of this and more than seventy years of commitment to customer satisfaction that Culligan is
providing this Performance Data Sheet to its customers. Data Sheet
NOTICE Read this Performance Data Sheet and compare the capabilities of this unit with your actual
water treatment needs. It is recommended that before purchasing a water treatment unit, you
have your water supply tested to determine your actual water treatment needs.
Culligan High
Efficiency 12"
Manufacturer: Culligan International Company
Water Softener
9399 W. Higgins Rd., Suite 1100, Rosemont, IL 60018 USA
(847) 430-2800
with Aqua-Sensor®
Sensing Device
Product: Culligan High Efficiency 12” Water Softener with Aqua-Sensor® Sensing Device
Softener Specifications:
Service Flow Rate: 10.0 gpm Pressure Drop at Max. Flow Rate: 10 psi (71 kPa)
Operating Temp. Range: 33-125°F (0.6–51.7°C) Max. Drain Flow Rate: 3.0 gpm
Working Press. Range: 20–120 psi (1.4–8.5 kg/cm2) Oper. Press. Range (Canada): 20–90 psi (1.4–6.3 kg/cm2)
USEPA Max.
Name of Substance Contaminant Level pH Flow Rate Pressure
Barium 2.0 mg/L 7.5 + 0.5 10.0 gpm 10 (psig)
Radium 226/228 5 pCi/L 7.5 + 0.5 10.0 gpm 10 (psig)
This system is certified for barium and radium 226/228 reduction based on hardness reduction. It is recommended
you test your water every 6 months to ensure the system is performing properly and that hardness, and therefore barium
and radium 226/228, are being reduced. Hardness test strips have been included. Additional strips are available
from your local Culligan dealer.
The Culligan High Efficiency 12” Water Softeners with Aqua-Sensor® Sensing Device are tested and certified by WQA
against NSF/ANSI Standard 372, CSA B483.1, NSF/ANSI Standard 44 for the effective reduction of hardness (cal-
cium and magnesium), barium, and radium 226/228, as verified and substantiated by test data.
An efficiency rated water softener is a DIR softener which also complies with specific performance specifications
intended to minimize the amount of regenerant brine and water used in its operation. Efficiency rated water softeners
shall have a rated salt efficiency of not less than 3350 grains of total hardness exchange per pound of salt (based on
NaCl equivalency) (477 grams of total hardness exchange per kilogram of salt), and shall not deliver more salt than
its listed rating. The efficiency is measured by a laboratory test described in NSF/ANSI 44. The test represents the
maximum possible efficiency the system can achieve. Operational efficiency is the actual efficiency achieved after the
system has been installed. It is typically less than the efficiency due to individual application factors including water
hardness, water usage, and other contaminants that reduce the softener’s capacity.
Refer to the Specifications, Familiarization and Warranty section of this Owner’s Guide for more specific product
information. To avoid contamination from improper handling and installation, your system should only be installed and
serviced by your Culligan Man. Performance will vary based on local water conditions. The substances reduced by this
system are not necessarily in your water.
Culligan water softeners are designed to work with any salt of good quality, although it is recommended that you ask
your local Culligan Man for his suggestion on the best type and grade of salt to use in this softener.
NOTICE This softener is not intended to be used for treating water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the system.
†
The efficiency rated dosage is only valid at the 8 lb. salt dosage and maxmum service flow rate for 12” models.
01021076 53
Performance Culligan knows the more informed you are about your water treatment systems, the more confident you will be about
its performance. It’s because of this and more than seventy years of commitment to customer satisfaction that Culligan is
Data Sheet providing this Performance Data Sheet to its customers.
NOTICE Read this Performance Data Sheet and compare the capabilities of this unit with your actual
Culligan High water treatment needs. It is recommended that before purchasing a water treatment unit, you
have your water supply tested to determine your actual water treatment needs.
Efficiency 14”
Water Softener Manufacturer: Culligan International Company
9399 W. Higgins Rd., Suite 1100, Rosemont, IL 60018 USA
with Soft-Minder®
(847) 430-2800
Meter
Product: Culligan High Efficiency 14” Water Softener with Soft-Minder® Meter
Softener Specifications:
Service Flow Rate: 10.6 gpm Pressure Drop at Max. Flow Rate: 11 psi
Operating Temp. Range: 33-125°F (0.6–51.7°C) Max. Drain Flow Rate: 2.5 gpm
Working Press. Range: 20–120 psi (1.4–8.5 kg/cm2) Oper. Press. Range (Canada): 20–90 psi (1.4–6.3 kg/cm2)
USEPA Max.
Name of Substance Contaminant Level pH Flow Rate Pressure
Barium 2.0 mg/L 7.5 + 0.5 10.6 gpm 11 (psig)
Radium 226/228 5 pCi/L 7.5 + 0.5 10.6 gpm 11 (psig)
This system is certified for barium and radium 226/228 reduction based on hardness reduction. It is recommended
you test your water every 6 months to ensure the system is performing properly and that hardness, and therefore barium
and radium 226/228, are being reduced. Hardness test strips have been included. Additional strips are available
from your local Culligan dealer.
The Culligan High Efficiency Series 14” Water Softeners with Soft-Minder® Meter are tested and certified by WQA
against NSF/ANSI Standard 372, CSA B483.1, NSF/ANSI Standard 44 for the effective reduction of hardness (cal-
cium and magnesium), barium, and radium 226/228, as verified and substantiated by test data.
An efficiency rated water softener is a DIR softener which also complies with specific performance specifications
intended to minimize the amount of regenerant brine and water used in its operation. Efficiency rated water softeners
shall have a rated salt efficiency of not less than 3350 grains of total hardness exchange per pound of salt (based on
NaCl equivalency) (477 grams of total hardness exchange per kilogram of salt), and shall not deliver more salt than
its listed rating. The efficiency is measured by a laboratory test described in NSF/ANSI 44. The test represents the
maximum possible efficiency the system can achieve. Operational efficiency is the actual efficiency achieved after the
system has been installed. It is typically less than the efficiency due to individual application factors including water
hardness, water usage, and other contaminants that reduce the softener’s capacity.
Refer to the Specifications, Familiarization and Warranty section of this Owner’s Guide for more specific product
information. To avoid contamination from improper handling and installation, your system should only be installed and
serviced by your Culligan Man. Performance will vary based on local water conditions. The substances reduced by this
system are not necessarily in your water.
Culligan water softeners are designed to work with any salt of good quality, although it is recommended that you ask
your local Culligan Man for his suggestion on the best type and grade of salt to use in this softener.
NOTICE This softener is not intended to be used for treating water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the system.
The efficiency rated dosage is only valid at the 12 lb. salt dosage and maxmum service flow rate for 14” models.
†
54 01021076
Culligan knows the more informed you are about your water treatment systems, the more confident you will be about
its performance. It’s because of this and more than seventy years of commitment to customer satisfaction that Culligan is
Performance
providing this Performance Data Sheet to its customers. Data Sheet
NOTICE Read this Performance Data Sheet and compare the capabilities of this unit with your actual
water treatment needs. It is recommended that before purchasing a water treatment unit, you
have your water supply tested to determine your actual water treatment needs.
Culligan High
Efficiency 14”
Manufacturer: Culligan International Company
Water Softener
9399 W. Higgins Rd., Suite 1100, Rosemont, IL 60018 USA
(847) 430-2800 with Aqua-Sensor®
Sensing Device
Product: Culligan High Efficiency 14” Water Softener with Aqua-Sensor® Sensing Device
Softener Specifications:
Service Flow Rate: 10.6 gpm Pressure Drop at Max. Flow Rate: 11 psi
Operating Temp. Range: 33-125°F (0.6–51.7°C) Max. Drain Flow Rate: 2.5 gpm
Working Press. Range: 20–120 psi (1.4–8.5 kg/cm2) Oper. Press. Range (Canada): 20–90 psi (1.4–6.3 kg/cm2)
USEPA Max.
Name of Substance Contaminant Level pH Flow Rate Pressure
Barium 2.0 mg/L 7.5 + 0.5 10.6 gpm 11 (psig)
Radium 226/228 5 pCi/L 7.5 + 0.5 10.6 gpm 11 (psig)
This system is certified for barium and radium 226/228 reduction based on hardness reduction. It is recommended
you test your water every 6 months to ensure the system is performing properly and that hardness, and therefore barium
and radium 226/228, are being reduced. Hardness test strips have been included. Additional strips are available
from your local Culligan dealer.
The Culligan High Efficiency 14” Water Softeners with Aqua-Sensor® Sensing Device are tested and certified by WQA
against NSF/ANSI Standard 372, CSA B483.1, NSF/ANSI Standard 44 for the effective reduction of hardness (cal-
cium and magnesium), barium, and radium 226/228, as verified and substantiated by test data.
An efficiency rated water softener is a DIR softener which also complies with specific performance specifications
intended to minimize the amount of regenerant brine and water used in its operation. Efficiency rated water softeners
shall have a rated salt efficiency of not less than 3350 grains of total hardness exchange per pound of salt (based on
NaCl equivalency) (477 grams of total hardness exchange per kilogram of salt), and shall not deliver more salt than
its listed rating. The efficiency is measured by a laboratory test described in NSF/ANSI 44. The test represents the
maximum possible efficiency the system can achieve. Operational efficiency is the actual efficiency achieved after the
system has been installed. It is typically less than the efficiency due to individual application factors including water
hardness, water usage, and other contaminants that reduce the softener’s capacity.
Refer to the Specifications, Familiarization and Warranty section of this Owner’s Guide for more specific product
information. To avoid contamination from improper handling and installation, your system should only be installed and
serviced by your Culligan Man. Performance will vary based on local water conditions. The substances reduced by this
system are not necessarily in your water.
Culligan water softeners are designed to work with any salt of good quality, although it is recommended that you ask
your local Culligan Man for his suggestion on the best type and grade of salt to use in this softener.
NOTICE This softener is not intended to be used for treating water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the system.
†
The efficiency rated dosage is only valid at the 12lb. salt dosage and maxmum service flow rate for 14” models.
01021076 55
Performance Culligan knows the more informed you are about your water treatment systems, the more confident you will be about
its performance. It’s because of this and more than seventy years of commitment to customer satisfaction that Culligan is
Data Sheet providing this Performance Data Sheet to its customers.
NOTICE Read this Performance Data Sheet and compare the capabilities of this unit with your actual
Culligan High water treatment needs. It is recommended that before purchasing a water treatment unit, you
have your water supply tested to determine your actual water treatment needs.
Efficiency 9”
Upflow Water Manufacturer: Culligan International Company
9399 W. Higgins Rd., Suite 1100, Rosemont, IL 60018 USA
Softener with Soft-
(847) 430-2800
Minder® Meter
Product: Culligan High Efficiency 9” Upflow Water Softener with Soft-Minder® Meter
Softener Specifications:
Service Flow Rate: 9.0 gpm Pressure Drop at Max. Flow Rate: 11 psi
Operating Temp. Range: 33-125°F (0.6–51.7°C) Max. Drain Flow Rate: 2.2 gpm
Working Press. Range: 20–120 psi (1.4–8.5 kg/cm2) Oper. Press. Range (Canada): 20–90 psi (1.4–6.3 kg/cm2)
USEPA Max.
Name of Substance Contaminant Level pH Flow Rate Pressure
Barium 2.0 mg/L 7.5 + 0.5 9.0 gpm 11 (psig)
Radium 226/228 5 pCi/L 7.5 + 0.5 9.0 gpm 11 (psig)
This system is certified for barium and radium 226/228 reduction based on hardness reduction. It is recommended you
test your water every six months to ensure the system is performing properly and that hardness, and therefore barium
and radium 226/228, are being reduced. Hardness test strips have been included. Additional strips are available
from your local Culligan dealer.
The Culligan High Efficiency Series 9” Upflow Water Softeners with Soft-Minder® Meter are tested and certified by
WQA against NSF/ANSI Standard 372, CSA B483.1, NSF/ANSI Standard 44 for the effective reduction of hardness
(calcium and magnesium), barium, and radium 226/228, as verified and substantiated by test data.
An efficiency rated water softener is a DIR softener which also complies with specific performance specifications
intended to minimize the amount of regenerant brine and water used in its operation. Efficiency rated water softeners
shall have a rated salt efficiency of not less than 3350 grains of total hardness exchange per pound of salt (based on
NaCl equivalency) (477 grams of total hardness exchange per kilogram of salt), and shall not deliver more salt than
its listed rating. The efficiency is measured by a laboratory test described in NSF/ANSI 44. The test represents the
maximum possible efficiency the system can achieve. Operational efficiency is the actual efficiency achieved after the
system has been installed. It is typically less than the efficiency due to individual application factors including water
hardness, water usage, and other contaminants that reduce the softener’s capacity.
Refer to the Specifications, Familiarization and Warranty section of this Owner’s Guide for more specific product
information. To avoid contamination from improper handling and installation, your system should only be installed and
serviced by your Culligan Man. Performance will vary based on local water conditions. The substances reduced by this
system are not necessarily in your water.
Culligan water softeners are designed to work with any salt of good quality, although it is recommended that you ask
your local Culligan Man for his suggestion on the best type and grade of salt to use in this softener.
NOTICE This softener is not intended to be used for treating water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the system.
The efficiency rated dosage is only valid at the 2 lb. salt dosage and maxmum service flow rate for 9” models.
†
56 01021076
Culligan knows the more informed you are about your water treatment systems, the more confident you will be about
its performance. It’s because of this and more than seventy years of commitment to customer satisfaction that Culligan is
Performance
providing this Performance Data Sheet to its customers. Data Sheet
NOTICE Read this Performance Data Sheet and compare the capabilities of this unit with your actual
water treatment needs. It is recommended that before purchasing a water treatment unit, you
have your water supply tested to determine your actual water treatment needs.
Culligan High
Efficiency 9”
Manufacturer: Culligan International Company
Upflow Water
9399 W. Higgins Rd., Suite 1100, Rosemont, IL 60018 USA
(847) 430-2800 Softener with
Aqua-Sensor®
Product: Culligan High Efficiency 9” Upflow Water Softener with Aqua-Sensor® Sensing Device Sensing Device
Testing Conditions & Results:
Flow Rate: 9.0 gpm @ 11 psi Capacity: 9,792 grains @ 2.0 lb. salt
Pressure: 30–40 psi (2.1–2.8 kg/cm2) 17,366 grains @ 4.0 lb. salt
Acidity: Non-Corrosive 27,306 grains @ 8.0 lb. salt
Temperature: 68°F (20°C)
Efficiency Rated Dosage†: 4,896 gr/lb pH: 7.6
Softener Specifications:
Service Flow Rate: 9.0 gpm Pressure Drop at Max. Flow Rate: 11 psi
Operating Temp. Range: 33-125°F (0.6–51.7°C) Max. Drain Flow Rate: 2.5 gpm
Working Press. Range: 20–120 psi (1.4–8.5 kg/cm2) Oper. Press. Range (Canada): 20–90 psi (1.4–6.3 kg/cm2)
USEPA Max.
Name of Substance Contaminant Level pH Flow Rate Pressure
Barium 2.0 mg/L 7.5 + 0.5 9.0 gpm 11 (psig)
Radium 226/228 5 pCi/L 7.5 + 0.5 9.0 gpm 11 (psig)
This system is certified for barium and radium 226/228 reduction based on hardness reduction. It is recommended you
test your water every six months to ensure the system is performing properly and that hardness, and therefore barium
and radium 226/228, are being reduced. Hardness test strips have been included. Additional strips are available
from your local Culligan dealer.
The Culligan High Efficiency 9” Upflow Water Softeners with Aqua-Sensor® Sensing Device are tested and certified by
WQA against NSF/ANSI Standard 372, CSA B483.1, NSF/ANSI Standard 44 for the effective reduction of hardness
(calcium and magnesium), barium, and radium 226/228, as verified and substantiated by test data.
An efficiency rated water softener is a DIR softener which also complies with specific performance specifications
intended to minimize the amount of regenerant brine and water used in its operation. Efficiency rated water softeners
shall have a rated salt efficiency of not less than 3350 grains of total hardness exchange per pound of salt (based on
NaCl equivalency) (477 grams of total hardness exchange per kilogram of salt), and shall not deliver more salt than
its listed rating. The efficiency is measured by a laboratory test described in NSF/ANSI 44. The test represents the
maximum possible efficiency the system can achieve. Operational efficiency is the actual efficiency achieved after the
system has been installed. It is typically less than the efficiency due to individual application factors including water
hardness, water usage, and other contaminants that reduce the softener’s capacity.
Refer to the Specifications, Familiarization and Warranty section of this Owner’s Guide for more specific product
information. To avoid contamination from improper handling and installation, your system should only be installed and
serviced by your Culligan Man. Performance will vary based on local water conditions. The substances reduced by this
system are not necessarily in your water.
Culligan water softeners are designed to work with any salt of good quality, although it is recommended that you ask
your local Culligan Man for his suggestion on the best type and grade of salt to use in this softener.
NOTICE This softener is not intended to be used for treating water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the system.
†
The efficiency rated dosage is only valid at the 2 lb. salt dosage and maxmum service flow rate for 9” models.
01021076 57
Performance Culligan knows the more informed you are about your water treatment systems, the more confident you will be about
its performance. It’s because of this and more than seventy years of commitment to customer satisfaction that Culligan is
Data Sheet providing this Performance Data Sheet to its customers.
NOTICE Read this Performance Data Sheet and compare the capabilities of this unit with your actual
Culligan High water treatment needs. It is recommended that before purchasing a water treatment unit, you
have your water supply tested to determine your actual water treatment needs.
Efficiency 10”
Upflow Water Manufacturer: Culligan International Company
9399 W. Higgins Rd., Suite 1100, Rosemont, IL 60018 USA
Softener with Soft-
(847) 430-2800
Minder® Meter
Product: Culligan High Efficiency 10” Upflow Water Softener with Soft-Minder® Meter
Softener Specifications:
Service Flow Rate: 9.4 gpm Pressure Drop at Max. Flow Rate: 12 psi
Operating Temp. Range: 33-125°F (0.6–51.7°C) Max. Drain Flow Rate: 2.3 gpm
Working Press. Range: 20–120 psi (1.4–8.5 kg/cm2) Oper. Press. Range (Canada): 20–90 psi (1.4–6.3 kg/cm2)
USEPA Max.
Name of Substance Contaminant Level pH Flow Rate Pressure
Barium 2.0 mg/L 7.5 + 0.5 9.4 gpm 12 (psig)
Radium 226/228 5 pCi/L 7.5 + 0.5 9.4 gpm 12 (psig)
This system is certified for barium and radium 226/228 reduction based on hardness reduction. It is recommended
you test your water every six months to ensure the system is performing properly and that hardness, and therefore
barium and radium 226/228, are being reduced. Hardness test strips have been included. Additional strips are avail-
able from your local Culligan dealer.
The Culligan High Efficiency Series 10” Upflow Water Softeners with Soft-Minder® Meter are tested and certified by
WQA against NSF/ANSI Standard 372, CSA B483.1, NSF/ANSI Standard 44 for the effective reduction of hardness
(calcium and magnesium), barium, and radium 226/228, as verified and substantiated by test data.
An efficiency rated water softener is a DIR softener which also complies with specific performance specifications
intended to minimize the amount of regenerant brine and water used in its operation. Efficiency rated water softeners
shall have a rated salt efficiency of not less than 3350 grains of total hardness exchange per pound of salt (based on
NaCl equivalency) (477 grams of total hardness exchange per kilogram of salt), and shall not deliver more salt than
its listed rating. The efficiency is measured by a laboratory test described in NSF/ANSI 44. The test represents the
maximum possible efficiency the system can achieve. Operational efficiency is the actual efficiency achieved after the
system has been installed. It is typically less than the efficiency due to individual application factors including water
hardness, water usage, and other contaminants that reduce the softener’s capacity.
Refer to the Specifications, Familiarization and Warranty section of this Owner’s Guide for more specific product
information. To avoid contamination from improper handling and installation, your system should only be installed and
serviced by your Culligan Man. Performance will vary based on local water conditions. The substances reduced by this
system are not necessarily in your water.
Culligan water softeners are designed to work with any salt of good quality, although it is recommended that you ask
your local Culligan Man for his suggestion on the best type and grade of salt to use in this softener.
NOTICE This softener is not intended to be used for treating water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the system.
The efficiency rated dosage is only valid at the 3 lb. salt dosage and maxmum service flow rate for 10” models.
†
58 01021076
Culligan knows the more informed you are about your water treatment systems, the more confident you will be about Performance
its performance. It’s because of this and more than seventy years of commitment to customer satisfaction that Culligan is
providing this Performance Data Sheet to its customers. Data Sheet
NOTICE Read this Performance Data Sheet and compare the capabilities of this unit with your actual
water treatment needs. It is recommended that before purchasing a water treatment unit, you
have your water supply tested to determine your actual water treatment needs.
Culligan High
Efficiency 10”
Manufacturer: Culligan International Company
Upflow Water
9399 W. Higgins Rd., Suite 1100, Rosemont, IL 60018 USA
(847) 430-2800
Softener with
Aqua-Sensor®
Product: Culligan High Efficiency 10” Upflow Water Softener with Aqua-Sensor® Sensing Device Sensing Device
Softener Specifications:
Service Flow Rate: 9.4 gpm Pressure Drop at Max. Flow Rate: 12 psi
Operating Temp. Range: 33-125°F (0.6–51.7°C) Max. Drain Flow Rate: 2.3 gpm
Working Press. Range: 20–120 psi (1.4–8.5 kg/cm2) Oper. Press. Range (Canada): 20–90 psi (1.4–6.3 kg/cm2)
USEPA Max.
Name of Substance Contaminant Level pH Flow Rate Pressure
Barium 2.0 mg/L 7.5 + 0.5 9.4 gpm 12 (psig)
Radium 226/228 5 pCi/L 7.5 + 0.5 9.4 gpm 12 (psig)
This system is certified for barium and radium 226/228 reduction based on hardness reduction. It is recommended
you test your water every six months to ensure the system is performing properly and that hardness, and therefore
barium and radium 226/228, are being reduced. Hardness test strips have been included. Additional strips are avail-
able from your local Culligan dealer.
The Culligan High Efficiency 10” Upflow Water Softeners with Aqua-Sensor® Sensing Device are tested and certified
by WQA against NSF/ANSI Standard 372, CSA B483.1, NSF/ANSI Standard 44 for the effective reduction of hard-
ness (calcium and magnesium), barium, and radium 226/228, as verified and substantiated by test data.
An efficiency rated water softener is a DIR softener which also complies with specific performance specifications
intended to minimize the amount of regenerant brine and water used in its operation. Efficiency rated water softeners
shall have a rated salt efficiency of not less than 3350 grains of total hardness exchange per pound of salt (based on
NaCl equivalency) (477 grams of total hardness exchange per kilogram of salt), and shall not deliver more salt than
its listed rating. The efficiency is measured by a laboratory test described in NSF/ANSI 44. The test represents the
maximum possible efficiency the system can achieve. Operational efficiency is the actual efficiency achieved after the
system has been installed. It is typically less than the efficiency due to individual application factors including water
hardness, water usage, and other contaminants that reduce the softener’s capacity.
Refer to the Specifications, Familiarization and Warranty section of this Owner’s Guide for more specific product
information. To avoid contamination from improper handling and installation, your system should only be installed and
serviced by your Culligan Man. Performance will vary based on local water conditions. The substances reduced by this
system are not necessarily in your water.
Culligan water softeners are designed to work with any salt of good quality, although it is recommended that you ask
your local Culligan Man for his suggestion on the best type and grade of salt to use in this softener.
NOTICE This softener is not intended to be used for treating water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the system.
†
The efficiency rated dosage is only valid at the 3 lb. salt dosage and maxmum service flow rate for 10” models.
01021076 59
Performance Culligan knows the more informed you are about your water treatment systems, the more confident you will be about
its performance. It’s because of this and more than seventy years of commitment to customer satisfaction that Culligan is
Data Sheet providing this Performance Data Sheet to its customers.
NOTICE Read this Performance Data Sheet and compare the capabilities of this unit with your actual
Culligan High water treatment needs. It is recommended that before purchasing a water treatment unit, you
have your water supply tested to determine your actual water treatment needs.
Efficiency Municipal
9" Water Softener Manufacturer: Culligan International Company
9399 W. Higgins Rd., Suite 1100, Rosemont, IL 60018 USA
(847) 430-2800
Product: Culligan High Efficiency Municipal 9” Water Softener
Softener Specifications:
Service Flow Rate: 9.0 gpm Pressure Drop at Max. Flow Rate: 12 psi
Operating Temp. Range: 33-125°F (0.6–51.7°C) Max. Drain Flow Rate: 2.6 gpm
Working Press. Range: 20–120 psi (1.4–8.5 kg/cm2) Oper. Press. Range (Canada): 20–90 psi (1.4–6.3 kg/cm2)
Substance Reduction
While testing was performed under standard laboratory conditions, actual performance may vary.
The Culligan HE Municipal 9” Water Softener is tested and certified by WQA against NSF/ANSI Standard 372, CSA
B483.1, and NSF/ANSI Standard 44 for the effective reduction of hardness (calcium and magnesium), and NSF/ANSI
Standard 42 for the effective reduction of Chlorine Taste and Odor, as verified and substantiated by test data.
An efficiency rated water softener is a DIR softener which also complies with specific performance specifications
intended to minimize the amount of regenerant brine and water used in its operation. Efficiency rated water softeners
shall have a rated salt efficiency of not less than 3350 grains of total hardness exchange per pound of salt (based on
NaCl equivalency) (477 grams of total hardness exchange per kilogram of salt), and shall not deliver more salt than
its listed rating. The efficiency is measured by a laboratory test described in NSF/ANSI 44. The test represents the
maximum possible efficiency the system can achieve. Operational efficiency is the actual efficiency achieved after the
system has been installed. It is typically less than the efficiency due to individual application factors including water
hardness, water usage, and other contaminants that reduce the softener’s capacity.
Refer to the Specifications, Familiarization and Warranty section of this Owner’s Guide for more specific product
information. To avoid contamination from improper handling and installation, your system should only be installed and
serviced by your Culligan Man. Performance will vary based on local water conditions. The substances reduced by this
system are not necessarily in your water.
Culligan water softeners are designed to work with any salt of good quality, although it is recommended that you ask
your local Culligan Man for his suggestion on the best type and grade of salt to use in this softener.
NOTICE This softener is not intended to be used for treating water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the system.
The efficiency rated dosage is valid only at the 4lb. salt dosage and 9.0 gpm flow rate for 9” models.
†
60 01021076
Culligan knows the more informed you are about your water treatment systems, the more confident you will be about
its performance. It’s because of this and more than seventy years of commitment to customer satisfaction that Culligan is
Performance
providing this Performance Data Sheet to its customers. Data Sheet
NOTICE Read this Performance Data Sheet and compare the capabilities of this unit with your actual
water treatment needs. It is recommended that before purchasing a water treatment unit, you
have your water supply tested to determine your actual water treatment needs.
Culligan High
Efficiency Municipal
Manufacturer: Culligan International Company
10" Water Softener
9399 W. Higgins Rd., Suite 1100, Rosemont, IL 60018 USA
(847) 430-2800
Product: Culligan High Efficiency Municipal 10” Water Softener
Softener Specifications:
Service Flow Rate: 9.4 gpm Pressure Drop at Max. Flow Rate: 11 psi
Operating Temp. Range: 33-125°F (0.6–51.7°C) Max. Drain Flow Rate: 2.6 gpm
Working Press. Range: 20–120 psi (1.4–8.5 kg/cm2) Oper. Press. Range (Canada): 20–90 psi (1.4–6.3 kg/cm2)
Substance Reduction
While testing was performed under standard laboratory conditions, actual performance may vary.
The Culligan HE Municipal 10” Water Softener is tested and certified by WQA against NSF/ANSI Standard 372, CSA
B483.1, and NSF/ANSI Standard 44 for the effective reduction of hardness (calcium and magnesium), and NSF/ANSI
Standard 42 for the effective reduction of Chlorine Taste and Odor, as verified and substantiated by test data.
An efficiency rated water softener is a DIR softener which also complies with specific performance specifications
intended to minimize the amount of regenerant brine and water used in its operation. Efficiency rated water softeners
shall have a rated salt efficiency of not less than 3350 grains of total hardness exchange per pound of salt (based on
NaCl equivalency) (477 grams of total hardness exchange per kilogram of salt), and shall not deliver more salt than
its listed rating. The efficiency is measured by a laboratory test described in NSF/ANSI 44. The test represents the
maximum possible efficiency the system can achieve. Operational efficiency is the actual efficiency achieved after the
system has been installed. It is typically less than the efficiency due to individual application factors including water
hardness, water usage, and other contaminants that reduce the softener’s capacity.
Refer to the Specifications, Familiarization and Warranty section of this Owner’s Guide for more specific product
information. To avoid contamination from improper handling and installation, your system should only be installed and
serviced by your Culligan Man. Performance will vary based on local water conditions. The substances reduced by this
system are not necessarily in your water.
Culligan water softeners are designed to work with any salt of good quality, although it is recommended that you ask
your local Culligan Man for his suggestion on the best type and grade of salt to use in this softener.
NOTICE This softener is not intended to be used for treating water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the system.
The efficiency rated dosage is valid only at the 5 lb. salt dosage and 9.4 gpm flow rate for 10” models.
†
01021076 61
Performance Culligan knows the more informed you are about your water treatment systems, the more confident you will be about
its performance. It’s because of this and more than seventy years of commitment to customer satisfaction that Culligan is
Data Sheet providing this Performance Data Sheet to its customers.
NOTICE Read this Performance Data Sheet and compare the capabilities of this unit with your actual
Culligan High water treatment needs. It is recommended that before purchasing a water treatment unit, you
have your water supply tested to determine your actual water treatment needs.
Efficiency Municipal
12” Water Softener Manufacturer: Culligan International Company
9399 W. Higgins Rd., Suite 1100, Rosemont, IL 60018 USA
(847) 430-2800
Product: Culligan High Efficiency Municipal 12” Water Softener
Softener Specifications:
Service Flow Rate: 10.0 gpm Pressure Drop at Max. Flow Rate: 11 psi
Operating Temp. Range: 33-125°F (0.6–51.7°C) Max. Drain Flow Rate: 3.2 gpm
Working Press. Range: 20–120 psi (1.4–8.5 kg/cm2) Oper. Press. Range (Canada): 20–90 psi (1.4–6.3 kg/cm2)
Substance Reduction
While testing was performed under standard laboratory conditions, actual performance may vary.
The Culligan HE Municipal 12” Water Softener is tested and certified by WQA against NSF/ANSI Standard 372, CSA
B483.1, and NSF/ANSI Standard 44 for the effective reduction of hardness (calcium and magnesium), and NSF/ANSI
Standard 42 for the effective reduction of Chlorine Taste and Odor, as verified and substantiated by test data.
An efficiency rated water softener is a DIR softener which also complies with specific performance specifications
intended to minimize the amount of regenerant brine and water used in its operation. Efficiency rated water softeners
shall have a rated salt efficiency of not less than 3350 grains of total hardness exchange per pound of salt (based on
NaCl equivalency) (477 grams of total hardness exchange per kilogram of salt), and shall not deliver more salt than
its listed rating. The efficiency is measured by a laboratory test described in NSF/ANSI 44. The test represents the
maximum possible efficiency the system can achieve. Operational efficiency is the actual efficiency achieved after the
system has been installed. It is typically less than the efficiency due to individual application factors including water
hardness, water usage, and other contaminants that reduce the softener’s capacity.
Refer to the Specifications, Familiarization and Warranty section of this Owner’s Guide for more specific product
information. To avoid contamination from improper handling and installation, your system should only be installed and
serviced by your Culligan Man. Performance will vary based on local water conditions. The substances reduced by this
system are not necessarily in your water.
Culligan water softeners are designed to work with any salt of good quality, although it is recommended that you ask
your local Culligan Man for his suggestion on the best type and grade of salt to use in this softener.
NOTICE This softener is not intended to be used for treating water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the system.
The efficiency rated dosage is valid only at the 7 lb. salt dosage and 10.0 gpm flow rate for 12” models.
†
62 01021076
Culligan knows the more informed you are about your water treatment systems, the more confident you will be about
its performance. It’s because of this and more than seventy years of commitment to customer satisfaction that Culligan is
Performance
providing this Performance Data Sheet to its customers. Data Sheet
NOTICE Read this Performance Data Sheet and compare the capabilities of this unit with your actual
water treatment needs. It is recommended that before purchasing a water treatment unit, you
have your water supply tested to determine your actual water treatment needs.
Culligan High
Efficiency Municipal
Manufacturer: Culligan International Company
14” Water Softener
9399 W. Higgins Rd., Suite 1100, Rosemont, IL 60018 USA
(847) 430-2800
Product: Culligan High Efficiency Municipal 14” Water Softener
Softener Specifications:
Service Flow Rate: 10.6 gpm Pressure Drop at Max. Flow Rate: 11 psi
Operating Temp. Range: 33-125°F (0.6–51.7°C) Max. Drain Flow Rate: 6.2 gpm
Working Press. Range: 20–120 psi (1.4–8.5 kg/cm2) Oper. Press. Range (Canada): 20–90 psi (1.4–6.3 kg/cm2)
Substance Reduction
While testing was performed under standard laboratory conditions, actual performance may vary.
The Culligan HE Municipal 14” Water Softener is tested and certified by WQA against NSF/ANSI Standard 372, CSA
B483.1, and NSF/ANSI Standard 44 for the effective reduction of hardness (calcium and magnesium), and NSF/ANSI
Standard 42 for the effective reduction of Chlorine Taste and Odor, as verified and substantiated by test data.
An efficiency rated water softener is a DIR softener which also complies with specific performance specifications
intended to minimize the amount of regenerant brine and water used in its operation. Efficiency rated water softeners
shall have a rated salt efficiency of not less than 3350 grains of total hardness exchange per pound of salt (based on
NaCl equivalency) (477 grams of total hardness exchange per kilogram of salt), and shall not deliver more salt than
its listed rating. The efficiency is measured by a laboratory test described in NSF/ANSI 44. The test represents the
maximum possible efficiency the system can achieve. Operational efficiency is the actual efficiency achieved after the
system has been installed. It is typically less than the efficiency due to individual application factors including water
hardness, water usage, and other contaminants that reduce the softener’s capacity.
Refer to the Specifications, Familiarization and Warranty section of this Owner’s Guide for more specific product
information. To avoid contamination from improper handling and installation, your system should only be installed and
serviced by your Culligan Man. Performance will vary based on local water conditions. The substances reduced by this
system are not necessarily in your water.
Culligan water softeners are designed to work with any salt of good quality, although it is recommended that you ask
your local Culligan Man for his suggestion on the best type and grade of salt to use in this softener.
NOTICE This softener is not intended to be used for treating water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the system.
The efficiency rated dosage is valid only at the 9 lb. salt dosage and 10.6 gpm flow rate for 14” models.
†
01021076 63
California State of California
Department of Department of Public Health
Public Health Water Treatment Device
Certificate Certificate Number
10 - 2044
Culligan High Date Issued: August 2, 2010
Efficiency 9” Water
Softener
9” Soft-Minder Meter
Upflow 9” Aqua-Sensor
The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section
116830 of the Health and Safety Code for the following health related contaminants:
Do not use where water is microbiologically unsafe or with water of unknown quality, except that systems
certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
64 01021076
State of California California
Department of Public Health Department of
Water Treatment Device Public Health
Certificate Number Certificate
10 - 2043
Date Issued: August 2, 2010 Culligan High
Efficiency 10”
Water Softener
The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section
116830 of the Health and Safety Code for the following health related contaminants:
Do not use where water is microbiologically unsafe or with water of unknown quality, except that systems
certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
01021076 65
California State of California
Department of Department of Public Health
Public Health Water Treatment Device
Certificate Certificate Number
10 - 2046
Culligan High
Date Issued: August 2, 2010
Efficiency 12”
Water Softener
The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section
116830 of the Health and Safety Code for the following health related contaminants:
Do not use where water is microbiologically unsafe or with water of unknown quality, except that systems
certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
66 01021076
State of California California
Department of Public Health Department of
Water Treatment Device Public Health
Certificate Number Certificate
10 - 2045
Date Issued: August 2, 2010
Culligan High
Efficiency 14”
Water Softener
The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section
116830 of the Health and Safety Code for the following health related contaminants:
Do not use where water is microbiologically unsafe or with water of unknown quality, except that systems
certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
01021076 67
Important It is advisable to have the salesperson or installer fill in the information below for your future reference. If
this has not been done, please ask for it, as it is necessary if you contact your dealer.
Data on Your
Water Filter Identification
Model Name ________________________________ Catalog No. _______________________________
Settings
Time of Recharge: ____________________________ a.m. / ______________________________ p.m.
Water Analysis
Total Hardness ____________________________________________________________________ (gpg)
pH (acidity) _____________________________________________________________________________
Other____________________________________________________________________________________
________________________________________________________________________________________
________________________________________________________________________________________
________________________________________________________________________________________
68 01021076
RED WIRE
RED WIRE
FRONT EMPTY
GREEN WIRE
BLACK WIRE BLACK WIRE
DISPLAY
GREEN WIRE
POSITION
MOTOR BLACK WIRE
RED WIRE BACK
BLACK WIRE
KEYPAD CONNECTOR
PHONE
FLOW METER
CONNECTOR
RED WIRE
2.5v 24v
Red
Blue
Black
White
Aqua-Sensor power
cable should be
plugged to 2.5VAC
connectors—left side
BLACK WIRE
POWER FLOW
CABLE PLUGS
METER
CABLE
AQUA-SENSOR PROBE
01021076
69
Schematic
Electrical
70
Parts List
High Efficiency
Indoor Assembly
01021076
O-RING GROOVES
35 85*
84 & 85 UPFLOW ONLY
84*
34
14
45
48
46
47 8
50
49
8 60
15
12 1
O-RING GROOVES
25 11
16
QUAD-RING GROOVE
61
50
64
18
13
20
2
24 4
5
17 29 23
19
51
5
2 8
37
55 38
53 83 39
29 24
6
7
O-RING GROOVES
9
QUAD-RING GROOVE
5 10 40
65 28
54
62
32
63
57
41 31
42
Part Part
Item Description Item Description
Number Number
01023111 HE Control Valve, Dowflow, Complete Eductor Throat with O-rings, Upflow, White (10" Tanks),
P1023713
10ea/Kit
01023115 HE Control Valve, Upflow, Complete
46 P1020603 Eductor Throat O-ring, Large, 10ea/Kit
1 01023020 Valve Body
47 P1020428 Eductor Throat O-ring, Small, 10ea/Kit
Piston Rebuild Kit, Includes 6ea Piston assem-blies and
2 01022791
1ea Brine Piston Assembly Eductor Nozzle w/ O-ring, Blue (9” & 10” tanks), 10ea/
48 P1013894
Kit
4 01020440 Gear Box Assembly, Downflow
Eductor Nozzle w/ O-ring, Beige (10” & 12” tanks),
01022234 Gear Box Assembly, Upflow P1013895
10ea/Kit
5 01020240 Gearmotor 00447752 Eductor Nozzle w/ O-ring, Green (14” tanks)
6 P1020415 Retainer, Gearmotor, 10ea/Kit 49 P0308438 O-ring, Eductor Nozzle, 10ea/Kit
7 01020420 Wire Harness w/ Optical Sensor 50 P1020256 Screen, 10ea/Kit
8 01022735 Wire Harness, Motor 51 01014153 Tank Adapter Assy, 1” valve to tank less O-Rings
9 P1020433 Optical Sensor Screw, 10ea/Kit 52 01013958 Tank Adapter, 1” Valve
10 P1020517 Gear Box Assembly Screw, 10ea/Kit 53 P1013959 Tank Clamp, 1” Valve
11 P1020289 Dial-a-Softness Knob, 10ea/Kit 54 P1013669 Tank Clamp Pin, 1” Valve
12 P1020427 Dial-a-Softness Assembly w/ O-Rings, 10ea/Kit 55 P0318383 Tank Clamp Screw, 1” Valve/3/4” bkt
13 P0440268 O-Ring, Brine & Drain Elbow, 10ea/Kit 56 P1014848 O-ring, Large, Valve to Tank Adapter
14 P1020487 Eductor Plug Assembly w/ O-Rings, 10ea/Kit 57 P0440052 O-ring, Valve Adapter to ACME Tank
15 P1020290 Eductor Plug Retainer, 10ea/Kit 60 P1020431 Main Piston O-ring, 25ea/Kit
16 P1023051 Dial-a-Softness Locking Plug, 10ea/Kit 61 P1020430 Main Piston Quad Ring, 25ea/Kit
17 P1020291 Dial-a-Softness Locking Plug Retainer 62 P1020426 Brine Piston O-ring 25ea/Kit
18 P1020581 Brine Elbow Assembly, 10ea/Kit 63 P1021881 Brine Piston Quad Ring 25ea/Kit
19 P1020432 Retainer, Brine & Drain Elbow, 10ea/Kit 64 P1020252 Main Piston Spring, 10ea/Kit
20 P1023021 Drain Elbow Assembly, 10ea/Kit 65 P1020286 Brine Piston Spring 10ea/Kit
23 01023014 Enclosure Frame 69 01018760 Bypass Valve, Rotary
Backwash Flow Control, #2 Brown (9" & 10" Tanks), 70 P1009075 Retaining Clip, 1” Bypass valve
24 P0331635
10ea/Kit
71 01014033 Coupling Kit - 1” Bypass
P0331636 Backwash Flow Control, #3 Green (12" Tanks), 10ea/Kit
72 P1009099 O-ring, Couplings/Meters
P0401031 Backwash Flow Control, Black (14" Tanks), 10ea/ Kit
82 01011188 Meter Kit - 1” w/wire harness
25 01023066 Control Valve Cover
83 01023117 Wire Harness, Meter, 28"Long
28 P0318383 Enclosure Screw, 10ea/Kit
Half Ball w/ Post, Upflow Only, 10ea/Kit (only upflow
29 P1023122 Retainer for Enclosure Screw, 10ea/Kit 84 P1023699
models)
31 P1000372 Strain Relief Fitting, 10ea/Kit 85 P1023695 Spring, Upflow Only, 10ea/Kit (only upflow models)
32 P1006498 Plug, 10ea/Kit * P0451701 Hose Clamp, Drain
34 P1021162 O-ring, Eductor Plug Assembly, Large, 10ea/Kit * 01018249 1 1/4” Straight Through Adapter
35 P1020424 O-ring, Eductor Plug Assembly, Small, 10ea/Kit * 01018755 Rebuild Kit - 1”/1-1/4” Rotary Bypass
37 01017134 Power Cord * P1019646 Replacement O-Ring for Bypass Valve Stem, 50ea/Kit
38 P1017264 Power Cord Connector, 10ea/Kit * 01010783 1” Copper Adapter Kit, (1” Bypass)
39 01023448 Electronics Enclosure Kit less Circuit Board * 01016564 3/4” Copper Adapter Kit (1” Bypass)
40 01023447 Replacement Circuit Board * 01016565 3/4” Elbow Copper Adapter Kit (1” Bypass)
41 P1023112 Circuit Board Label, 10ea/Kit * P1018757 1” NPT Female Elbow Kit (1” Rotary Bypass)
42 P1020497 Keypad with Connector, 10ea/Kit * P1009856 Gasket, Copper Plumbing Adapters
Eductor Throat with O-rings, Downflow, Tan (9, 10 & 12" * 01018133 Transformer, Dual Output
45 P1022796
Tanks), 10ea/Kit
* 01020620 Transformer, Dual Output w/ 6' Power Cord
Eductor Throat with O-rings, Downflow, Blue (14" Tanks),
P1022723
10ea/Kit * Not shown
Eductor Throat with O-rings, Upflow, Gray (9" Tanks),
P1023712
10ea/Kit
01021076 71
72
Parts List
High Efficiency
Outdoor Assembly
01021076
26 72
O-RING GROOVES
35 85*
84 & 85 UPFLOW ONLY
84*
34
14 69
45 60
83
48 70
46 71
47
O-RING GROOVES
50 82
49
QUAD-RING GROOVE
15
12 61
34 64
11
16
1 O-RING GROOVES
18 QUAD-RING GROOVE
65
50
46 62
20
13
17
24 63
2
43
23
4
10
39 19
42 40
31
56 5
2
40
27 22
55 33
53
6 7 9
25
52
54
57
Part Part
Item Description Item Description
Number Number
01023120 HE Outdoor Control Valve, Downflow, Complete Eductor Throat with O-rings, Upflow, Gray (9" Tanks),
P1023712
10ea/Kit
01023121 HE Outdoor Control Valve, Upflow, Complete
Eductor Throat with O-rings, Upflow, White (10" Tanks),
1 01023020 Valve Body P1023713
10ea/Kit
Piston Rebuild Kit, Includes 6ea Piston assem-blies and 46 P1020603 Eductor Throat O-ring, Large, 10ea/Kit
2 01022791
1ea Brine Piston Assembly
47 P1020428 Eductor Throat O-ring, Small, 10ea/Kit
4 01020440 Gear Box Assembly, Downflow
Eductor Nozzle w/ O-ring, Blue (9” & 10” tanks), 10ea/
01022234 Gear Box Assembly, Upflow 48 P1013894
Kit
5 01020240 Gearmotor Eductor Nozzle w/ O-ring, Beige (10” & 12” tanks),
P1013895
6 P1020415 Retainer, Gearmotor, 10ea/Kit 10ea/Kit
7 01020420 Wire Harness w/ Optical Sensor 00447752 Eductor Nozzle w/ O-ring, Green (14” tanks)
10 P1020517 Gear Box Assembly Screw, 10ea/Kit 51 01014153 Tank Adapter Assy, 1” valve to tank less O-Rings
13 P0440268 O-Ring, Brine & Drain Elbow, 10ea/Kit 54 P1013669 Tank Clamp Pin, 1” Valve
14 P1020487 Eductor Plug Assembly w/ O-Rings, 10ea/Kit 55 P0318383 Tank Clamp Screw, 1” Valve/3/4” bkt
15 P1020290 Eductor Plug Retainer, 10ea/Kit 56 P1014848 O-ring, Large, Valve to Tank Adapter
16 P1023051 Dial-a-Softness Locking Plug, 10ea/Kit 57 P0440052 O-ring, Valve Adapter to ACME Tank
17 P1020291 Dial-a-Softness Locking Plug Retainer 60 P1020431 Main Piston O-ring, 25ea/Kit
18 P1020581 Brine Elbow Assembly, 10ea/Kit 61 P1020430 Main Piston Quad Ring, 25ea/Kit
P1018871 Insert, Brine Line Connector, 3/8” 62 P1020426 Brine Piston O-ring 25ea/Kit
P1002205 Nut, Brine Line Connector, 3/8” 63 P1021881 Brine Pston Quad Ring 25ea/Kit
19 P1020432 Retainer, Brine & Drain Elbow, 10ea/Kit 64 P1020252 Main Piston Spring, 10ea/Kit
20 P1023021 Drain Elbow Assembly, 10ea/Kit 65 P1020286 Brine Piston Spring 10ea/Kit
Backwash Flow Control, #2 Brown (9" & 10" Tanks), 71 01014033 Coupling Kit - 1” Bypass
24 P0331635
10ea/Kit 72 P1009099 O-ring, Couplings/Meters
P0331636 Backwash Flow Control, #3 Green (12" Tanks), 10ea/Kit 82 01011188 Meter Kit - 1” w/wire harness
P0401031 Backwash Flow Control, Black (14" Tanks), 10ea/ Kit 83 01023117 Wire Harness, Meter, 28"Long
25 01021040 Enclosure Tray, Outdoor Half Ball w/ Post, Upflow Only, 10ea/Kit (only upflow
84 P1023699
26 01021041 Enclosure, Outdoor models)
27 P1020590 Enclosure Plug, 10ea/Kit 85 P1023695 Spring, Upflow Only, 10ea/Kit (only upflow models)
33 P1022777 Screw for Outdoor Enclosure, 10ea/Kit * P0451701 Hose Clamp, Drain
34 P1021162 O-ring, Eductor Plug Assembly, Large, 10ea/Kit * 01018249 1 1/4” Straight Through Adapter
35 P1020424 O-ring, Eductor Plug Assembly, Small, 10ea/Kit * 01018755 Rebuild Kit - 1”/1-1/4” Rotary Bypass
37 01017134 Power Cord * P1019646 Replacement O-Ring for Bypass Valve Stem, 50ea/Kit
38 P1017264 Power Cord Connector, 10ea/Kit * 01010783 1” Copper Adapter Kit, (1” Bypass)
39 01022800 Electronics Enclosure Kit less Circuit Board * 01016564 3/4” Copper Adapter Kit (1” Bypass)
40 01020745 Replacement Circuit Board * 01016565 3/4” Elbow Copper Adapter Kit (1” Bypass)
41 P1020496 Push Button Label, 10ea/Kit * 01018757 1” NPT Female Elbow Kit (1” Rotary Bypass)
42 P1020497 Keypad with Connector, 10ea/Kit * P1009856 Gasket, Copper Plumbing Adapters
44 01017134 Power Cord * 01020620 Transformer, Dual Output w/ 6' Power Cord
45 P1022796
Eductor Throat with O-rings, Downflow, Tan (9, 10 & 12" * Not shown
Tanks), 10ea/Kit
Eductor Throat with O-rings, Downflow, Blue (14" Tanks),
P1022723
10ea/Kit
01021076 73
Parts List
Remote Display
and Smart Brine
Tank Sensor
B
3
2
1
74 01021076
Part Parts List
Item Description Qty
No.
Tank Assembly, 9” w/ Fill-
1 01016617
port, Complete Tank Assembly
8 Tank Assembly, 10” w/ Fill-
01016618
port, Complete
Tank Assembly, 12” w/ Fill-
01017192
port, Complete, Less Media
Tank Assembly, 14” w/ Fill-
01017194
port, Complete, Less Media
Tank Assembly, 9” w/o Fill-
01016351
port, Complete
Tank Assembly, 10” w/o Fill-
01016352
port, Complete
Tank Replacement, 9”, w/
01016349
Fillport, Empty
Tank Replacement, 10”, w/
01016350
Fillport, Empty
Tank Replacement, 12”, w/
01016520
Fillport, Empty
Tank Replacement, 14”, w/
01016522
Fillport, Empty
Tank Replacement, 9”, w/o
01016347
Fillport, Empty
Tank Replacement, 10”, w/o
01016348
Fillport, Empty
6 01015122 Plug 1
3
5
01021076 77
Parts List Item Part No. Description
2
- 01018720 Brine System, 650 lb
24" Brine System
1 01018718 Replacement Tank, 650 lb
3
2 01018719 Cover, 650 lb
78 01021076
Culligan High Efficiency Automatic Water Conditioners Culligan
You have just purchased one of the finest water conditioners made. As an expression of our confidence Limited
in Culligan International Company products, your water conditioner is warranted to the original end-user,
when installed in accordance with Culligan specifications, against defects in material and workmanship
Warranty
from the date of original installation, as follows:
For a period of ONE The entire conditioner and Culligan HE Municipal Media
YEAR
For a period of FIVE YEARS Remote display, modem, Soft-Minder® meter, Smart Brine probe,
or Aqua-Sensor® probe, if so equipped.
For a period of TEN YEARS High Efficiency circuit board, control valve body, excluding inter-
nal parts.
The salt storage container, brine valve and all its component parts
For the LIFETIME of the The Quadra-Hull™ conditioner tank and the Cullex® resin
original consumer purchaser
If a part described above is found defective within the specified period, you should notify your indepen-
dently operated Culligan dealer and arrange a time during normal business hours for the dealer to inspect
the water conditioner on your premises. Any part found defective within the terms of this warranty will be
repaired or replaced by the dealer. You pay only freight from our factory and local dealer charges.
We are not responsible for damage caused by accident, fire, flood, freezing, Act of God, misuse, misap-
plication, neglect, oxidizing agents (such as chlorine, ozone, chloramines and other related components),
alteration, installation or operation contrary to our printed instructions, or by the use of accessories or com-
ponents which do not meet Culligan specifications, is not covered by this warranty. Refer to the specifica-
tions section in the Installation and Operating manual for application parameters.
Our product performance specifications are furnished with each water conditioning unit. TO THE EXTENT
PERMITTED BY LAW, CULLIGAN DISCLAIMS ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITA-
TION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE; TO THE EXTENT
REQUIRED BY LAW, ANY SUCH IMPLIED WARRANTIES ARE LIMITED IN DURATION TO THE ONE-YEAR
PERIOD SPECIFIED ABOVE FOR THE ENTIRE CONDITIONER. As a manufacturer, we do not know the
characteristics of your water supply or the purpose for which you are purchasing a water conditioner.
The quality of water supplies may vary seasonally or over a period of time, and your water usage rate
may vary as well. Water characteristics can also differ considerably if your water conditioner is moved to
a new location. For these reasons, we assume no liability for the determination of the proper equipment
necessary to meet your requirements, and we do not authorize others to assume such obligations for us.
Further, we assume no liability and extend no warranties, express or implied, for the use of this product
with a non-potable water source. OUR OBLIGATIONS UNDER THIS WARRANTY ARE LIMITED TO THE
REPAIR OR REPLACEMENT OF THE FAILED PARTS OF THE WATER CONDITIONER, AND WE ASSUME
NO LIABILITY WHATSOEVER FOR DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, SPECIAL, GEN-
ERAL, OR OTHER DAMAGES.
Some states do not allow the exclusion of implied warranties or limitations on how long an implied war-
ranty lasts, so the above limitation may not apply to you. Similarly, some states do not allow the exclusion
of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This
warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Consult your telephone directory for your local independently operated Culligan dealer, or write Culligan
International Company for warranty and service information.
80 01021076
A Drain facilities 10, 12 Index
Application 9 Drain Line Connection , 21
AquaSensor 46 Dubl-Safe™ valve 7
Aqua-Sensor® Device 2 E
Aqua-Sensor, Install 12
Aqua-Sensor® Mode , 8 Eductor 15
Aqua-Sensor plug 14 Eductor Nozzle and Throat Replacement 14
Aqua-Sensor® Start-Up Procedure 40 Eductor Nozzle Replacement 15
Aqua Sens Probe 46 Eductor Nozzle—Throat , 15
Attaching the Cover 15 Electrical facilities 10, 12
Electrical Installation 32
B Electrical Schematic 67
Backwash Flow Control 13 Error Codes 44
Backwash Flow Control Replacement , 16, 17, 18 F
Bacterial Iron 4
Blown Fuse 43 Few Days Salt 46
blue bypass knob 21 Final Startup 37
Brine Blocked 46 First Time Setup 28
Brine Overfill 46 First Time Setup Procedure 28
Brine Refill , 7 Floor surface 9, 11
Brine Valve “A” Dimension , 23 Flow Restrictors 15
Brine valve tubing 22 G
Bypass Valve 45
Global Valve Assembly 70
Bypass valve assembly 20
Bypass Valve Installation , 19 H
Bypass Valves 43
Height of Discharge Above Floor Level Operating
Bypass Your Water Filter 45
22
C HE Twin cable lengths 14
High Efficiency 68, 70
California Department of Public Health Certificate
High Efficiency Water Conditioners with 2
64
How Your Water Conditioner Works 4
Call for Service 43
CANCEL or X button 26 I
Care and Cleaning of Your Water Conditioner 40
Immediate Regeneration 35
Check Brine Tank 46
Important Data on Your Water Filter 68
CHECK MARK button 26
Increased Usage 43
Circuit Board Connections , 23, 24
Indoor Assembly 68
Clean 43
Information 33
Cleaning 41
Inspection Schedule 42
Component 8
Install Aqua-Sensor 12
Connect the Brine Line 20
Installation 8
Control Valve 5, 14
Iron, Bacterial 4
Control Valve Assembly , 10
Iron, Dissolved 4
Cullex resin 7
Iron, Organic Bound 4
Cullsan® underbedding 7
Iron, Particulate 4
Customizing the Setup 33, 44
K
D
Keypad 26
Delayed Regeneration 35
Dial-a-Softness 7, 17, 18 L
Dial-a-Softness Knob 19
Line, Connect the Brine 20
Dissolved Iron 4
Loading the Tank 13
DOWN ARROW button 26
Location , 11
Downflow Regeneration 2
Low Battery 46
Down Flow Regeneration 7, 10, 12
Low Salt Level 46
01021076 81
M Remote Display 69, 71
Manual Regeneration , 8 Remote Display and Smart Brine Tank Sensor 72
Materials , 10 Replace Aux Filter Media 46
Media Tank , 10 Replace Ext Filt 46
Meter Start-Up Procedure 39 S
Mineral Tank , 7, 12
Mineral Tank(s) 10 Salt Bridging 46
Modem , 8 Salt Delivery Service , 41
Modes of Operation 6 Salt Economizer , 41
Motor Home Err 46 Salt Storage Container , 22
Motor Position Error 46 Salt Storage Tank 10
Mount the Control Valve , 14 Salt Storage Tank Assembly 8
Municipal Replacement Media Packs 75 Salt Supply , 41
Municipal Water Softener 4 Sanitizing Procedure , 44
Service , 7
N Set Date and Time 31
Navigating the Menus and Keypad 26 Smart Brine Tank Probe , 8
No Brine In Tank 46 Smart Brine Tank Sensor 72
No Refill 46 Soft-Minder® Meter 2
No Remote RF Signal 46 Space requirements 9, 11
No Remote Signal 46 Special Tools 8
No Water 43 Specifications 2
Standard Manual Regeneration 36
O Storage Tank , 43
Organic Bound Iron 4 T
Outdoor Assembly 70
Out the Salt , 43 Tank Assembly , 12, 12
Temperature , 11
P Test Modem , 46, 42, 48, 50, 52, 37, 56, 58
Particulate Iron 4 Tools 10
Performance Data Sheet 46, 47, 48, 49, 50, 51, Tools and Materials 8
52, 53, 56, 57, 58, 59, 60, 61, 62, 63 U
Placement , 12
Plumbing Connections , 19 UP ARROW button 26
Position Sensor Error 46 Upflow Regeneration 3, 9
Pos Sensor Err 46 W
Power Failure 43
Power Supply 43 Water Meter Mode , 8
Predict Mode , 8 Water Quality 9
Pre-Rinse Mode , 8 Wireless Remote Control , 8
Pressure 11, 9, 12, 13, 19 X
Preventative Maintenance 42
xxx-xxx-xxxx 46
Proportional Brining , 9
R
Recommended Aqua-Sensor® Start-Up Procedure
38
Recommended Meter Start-Up Procedure , 39
Recommended Preventative Maintenance Inspection
Schedule 40
Regeneration , 5, 7, 9