TYPE-71C
Administrator menu
Operation instructions
Table of contents
Overview 1
Accessing administrator menu 1
Function settings 2
Changing Passcode for administrator menu 4
Lock Functions 5
Administrator menu details 6
Changing settings 9
Analyzing fiber type 12
Registration of splice program 12
Release of splice program 14
Security (Startup password protection) 15
Overview
The administrator menu enables setting up further detailed functions.
The access to the menu is limited by pass code.
Menu Login
DATA
* * * 0
Splice Function Maintenance Security 1 2 3 4 5 6 7 8 9 0
Data
Q W E R T Y U I O P
A S D F G H J K L
USB Login Information Wireless
LAN
Z X C V B N M
2014/01/01 0000
1
Function settings
2
Page Functions Details
Light for v-groove This function sets the V-groove illumination to ON or OFF.
Postsplice Action This function sets the Postsplice Action to None-Open or
6/8 (Proof-Reset) Auto-Open or None-Key.
Opening Title1 Sets the message to be displayed when splicer power is
Opening Title2 turned on. Max number of characters: 13
Additional Arc This function sets the Additional Arc to ON or OFF.
Additional Arc Input This function sets the Additional Arc Input after splicing every
time to ON or OFF.
7/8 Caution for Arc Count This function sets the caution for arc count. For further
details, please refer to page 3-5 in guide to operation.
Warning for Arc Count This function sets the warning for arc count. For further
details, please refer to page 3-5 in guide to operation.
Change Administrator This function changes pass code of administrator menu.
Passcode
8/8
Lock Functions This function sets the lock of user menu to Enable or
Disable.
3
Changing Passcode for administrator menu
A passcode for login can be changed in the Administrator mode.
Menu Function
Arc Pause
DATA
ON
Function 1234
Lock Functions
Disable
1 2 3 4 5 6 7 8 9 0
8/8
Q W E R T Y U I O P
BS A S D F G H J K L
Z X C V B N M
Select Function OK
3: Change Administrator Pass code 4: Enter the current passcode.
is selected. The new passcode setup screen
is displayed. Enter a 4 digit new
passcode.
1234
(Example above: 1234)
Confirm new passcode for
administrator.
1 2 3 4 5 6 7 8 9 0
Q W E R T Y U I O P It becomes impossible to start when the
BS A S D F G H J K L passcode is forgotten.
Z X C V B N M
OK Please note it.
Please inquire of our maintenance
5: Enter the 4 digit new passcode
service center when you forget the
for confirmation.
(Example above: 1234) passcode by any chance.
4
Lock Functions
An administrator can lock splice and heater programs so that operator cannot
change them.
DATA
X/Y
Splice Function Maintenance Security
Data
Ready
2014/01/01 0000
Start
Select Item
Select
SelectItem
Item
1: Touch Function ( ) to go to 4: The splice and heater
function screen. programs are not changeable.
Touch the MENU icon. The
login screen will be displayed.
Function
Lock Functions
Disable
8/8
1 2 3 4 5 6 7 8 9 0
Q W E R T Y U I O P
A S D F G H J K L
Select Function Z X C V B N M
5
Administrator menu details
6
Page Item Description
6/8 Fiber Pulling ON or OFF the action of pulling fiber after overlapping fiber.
Fiber Pulling Start Sets the time of pulling fiber.
Fiber Pulling Length Sets the distance of pulling fiber.
7/8 Estimation Mode Sets the loss estimation method to High(HDCM) or
Standard. If High(HDCM) is chosen, the splicer will
observe and inspect the core of spliced fiber with very high
precision after fusion splicing.
MFD-L Sets the MFD of left side optical fiber.
MFD-R Sets the MFD of right side optical fiber.
Wavelength Sets the wavelength for loss estimation calculation.
8/8 Minimum Loss Sets the value to be added to an estimated loss.
Est. Loss Coef. Sets the coefficient for loss estimation.
MFD Mismatch Coef. Sets the coefficient for an estimated loss yielded due to
MFD mismatch.
<How an arc discharges and motors run during the splicing process>
7
<Heater program settings>
Page Item Description
1/3 Heat up Temp. A Temperature for the first half of the heating cycle.
(Numerical input)
Heating Duration A Duration for maintaining Heat Up Temp.A. (Numerical
input)
Heat up Temp. B Temperature for the latter half of the heating cycle.
(Numerical input)
Heating Duration B Duration for maintaining Heat Up Temp.B. (Numerical
input)
2/3 Finish Temp. The temperature of finishing heating cycle after
cooling by the fan. (Numerical input)
Preheating temperature* Temperature for the pre-heating duration of the
heating cycle. (Numerical input)
Preheating time* Duration for maintaining the Pre-heating Temp.
(Numerical input)
*When the heating process is started, the pre-heating
process is automatically finished.
Sleeve ID Name Change the protection sleeve name. (Text input)
3/3 Heat ID Name Change the heater programs name. (Text input)
*Quick Heater program only.
Temperature
Heat up Temp. A
Heat up Temp. B
Finish Temp.
Pre-heating Temp.
Time
Heating Duration A Heating Duration B
8
Changing settings
Example 1: Change Align Method from Core to Diameter.
Splice Program Splice Program
SM G652 Std. SM G652 Std.
Name Name SMF Quick
SM G652 Std. SM G652 Std.
Template 003 Template 003
SMF Quick SM G652 Std. SMF Quick SM G652 Std.
SMF Quick
AIAS Auto Power
SMF Quick OFF
9
Example 2: Change Arc Power. (Numerical input)
Splice Program Splice Program
SM G652 Std. SM G652 Std.
Name Arc Power
SM G652 Std. Standard + 0000 step
Template 003 Gapset Position
SMF Quick SM G652 Std. Standard + 0000 dot
+ 0 0 1 0 7 8 9 Arc Power
Standard + 0010 step
10
Example 3: Edit Splice Program Name.
Splice Program Splice Program
SM G652 Std. SM G652 Std.
Name Name
SM G652 Std. SM G652 Std.
Auto Power
SMF Quick Auto Power
SMF Quick
OFF OFF
! @ # $ % ^ & * ( ) 1 2 3 4 5 6 7 8 9 0
_ + , . -
< > ? : { } / ; [ ] =
Shift
Q W E R T Y U I O P q w e r t y u i o p
A S D F G H J K L a s d f g h j k l
Z X C V B N M z x c v b n m
Shift BS Shift BS
Default Cancel OK Default Cancel OK
3: Edit the name according to the key guidance shown on the screen.
11
Analyzing fiber type
APDS: Auto fiber Profiling check and Detection System
The splicer automatically analyzes optical fiber type to be spliced from fiber image,
compares the analyzed splice program to the selected splice program and displays the
result on a screen. This system prevents splice program and fiber type from being
miss-selected. When the analyzed fiber type is different from the set fiber type, the
result screen appears and the splicer stops.
Fiber types that can be analyzed are typically SMF, MMF, DSF/NZDS and BIF.
The right and left fibers are analyzed individually.
If a fiber profile cannot be identified, the splicer displays OTHER.
Note: The TYPE-71C+ fusion splicer stores the profiling information of representative
fiber types. Therefore the splicer could make miss-analysis on a different
manufacturers or new fiber types. With regard to profiling data customization and the
modification of fiber types, contact our maintenance service center or sales personnel.
Go on Next (ARC TEST) Change the splice program and perform an arc test.
Go on Next (SPLICE) Change the splice program and perform splice.
Override Ignore the result and continue to perform the splicing process.
Tips
The background of the splice program that is registered is shown in blue and
highlighted in green when selected.
The background of the splice program that is NOT registered is shown in black and the
text is highlighted in red when selected.
12
SM G652 Std. 60mm 0.25 Splice Program
MENU
NZDS
027
X/Y NZ G655 Typ.
028
NZ G655 Quick
Ready 029
1/43 G655-G652
DISP 030
PureGuide
Start Select Splice Program
Edit ON
Copy OFF
1/1 Memory 1/1
Splice Program
NZDS
027
NZ G655 Typ.
028
NZ G655 Quick
029
1/43 G655-G652
030
PureGuide
13
Release of splice program
The registered splice program that is currently selected cannot be released. Select
other splice program first and release the registered program.
Ready Ready
DISP DISP
Start Start
Tips
An administrator can also register a heater program, change settings
and edit sleeve names in the same way. Go to the administrator menu,
refer to page 4-7 of guide to operation, and go to the heater program
setting screen. Then refer to page 9 to 13.
14
Security (Startup password protection)
Using a startup password, Security function prevents unwanted users from
accessing the splicer. It is located in Security function on menu screen.
1234
Select Item
New startup password. By selecting Cycle, the setting that
demands the startup password for each
certain period (every day/every week/every
1 2 3 4 5 6 7 8 9 0
month) after the date when the startup
Q W E R T Y U I O P
A D
password demand can be done.
BS S F G H J K L
Z X C V B N M It becomes impossible to start when the start
OK
Setting startup password screen up password is forgotten. Please note it.
is displayed. Please set an Please inquire of our maintenance service
arbitrary password of four digits. center when you forget the startup password
ex) 1234
by any chance.
15
Revision D Aug. 25, 2015
Tokyo (JAPAN)
Sumitomo Electric Industries, Ltd.
(Global Business Dept.)
Akasaka Center Building, 1-3-13, Motoakasaka,
Minato-ku, Tokyo, 107-8468, JAPAN
Tel: +81-3-6406-2666
http://global-sei.com/sumitomo-electric-splicers
London (U.K)
Sumitomo Electric Europe Ltd.
220 Centennial Park, Centennial Avenue,
Elstree, Herts, WD6 3SL, U.K.
Tel: +44 20-8953-8118
http://www.sumielectric.com
Dubai (U.A.E.)
Middle East office
Dubai Airport Free Zone Phase 6 EA,
Office 303 P.O.Box 54890, Dubai, UAE
Tel: +971 4-701-7338