Technical literature for Optical Fiber Cable

TECHNICAL DATA SHEET


FOR
Single Mode Optical Fibre Cable
Direct Burial Application
Non-metallic CSM
(SM 6, 12, 24, 48 Fibers)

Page 1 of 6
Technical literature for Optical Fiber Cable

1. Cable Construction
1.1 Cable cross-section

2. Cable Specification
2.1 Sheath marking
TDGD 2015 GYFTY53 XXB1.3 (G.652D) XXXXm

TDGD : Manufacturers brand


2015 : Manufacture year
GYFTY53 : Cable type
XXB1.3 (G.652D) : XX cores single-mode optical fiber (ITU-T Rec. G.652D)
XXXXm : Mark of meters
*The marking is printed every 1 meter;
**G.652D means ITU-T Rec. Low Water Peak (LWP) G.652 Single Mode Optical Fiber.

2.2 The color of marking is white, but if the remarking is necessary, the yellow color marking shall
be printed newly on a different position.

2.3 An occasional unclear of length marking is permitted if both of the neighboring markings are
clear;

2.4 The both cable ends are sealed with heat shrinkable end caps to prevent water ingress.

Page 2 of 6
Technical literature for Optical Fiber Cable

2.5 Fiber color code


No. 1 2 3 4 5 6
Color Blue Orange Green Brown Gray White
No. 7 8 9 10 11 12
Color Red Black Yellow Violet Pink Aqua

2.6 Color Code for Loose Tube (LT) and Filler Rod (FR)
Fiber Element no.
count 1 2 3 4 5 6
6 LT FR FR FR FR FR

12 LT LT FR FR FR FR

24 LT LT LT LT FR FR

48 LT LT LT LT FR FR
* LT means Loose Tube;
** FR means Filler Rod;

2.7 Cable structure and parameter


I / O sheath
Max. fiber Total unit Overall diameter Weight
Fiber thickness
count count (nominal**) (approx.)
count (nominal*)
per tube (LT + FR)
mm mm kg/km

6 6 6(1LT+5FR) 1.0/1.6 13.6 174

12 6 6(2LT+4FR) 1.0/1.6 13.6 174

24 6 6(4LT+2FR) 1.0/1.6 13.6 175

48 12 6(4LT+2FR) 1.0/1.6 13.6 185


* The nominal sheath thickness may vary by 0.2mm.
** The nominal outer diameter and height may vary by 0.2mm.

Page 3 of 6
Technical literature for Optical Fiber Cable

3. Fiber Properties
3.1 The properties of single mode optical fiber (ITU-T Rec. G.652D)
Item Specification

Fiber type Single mode

Fiber material Doped silica

Attenuation coefficient
@ 1310 nm 0.35 dB/km
@ 1383 nm 0.35 dB/km
@ 1550 nm 0.21 dB/km
@ 1625 nm 0.30 dB/km

Point discontinuity 0.05 dB

Cable cut-off wavelength 1260 nm

Zero-dispersion wavelength 1300 ~ 1324 nm

Zero-dispersion slope 0.093 ps/(nm2.km)

Chromatic dispersion
@ 1288 ~ 1339 nm 3.5 ps/(nm. km)
@ 1271 ~ 1360 nm 5.3 ps/(nm. km)
@ 1550 nm 18 ps/(nm. km)
@ 1625 nm 22 ps/(nm. km)

PMD 0.2 ps/km1/2

Mode field diameter @ 1310 nm (8.6~9.5)0.6 um

Core / Clad concentricity error 0.6 um

Cladding diameter 125.0 1 um

Cladding non-circularity 1.0%

Primary coating diameter 245 10 um

Proof test level 100 kpsi (=0.69 Gpa), 1%

Temperature dependence
o o 0.1 dB/km
0 C~ +70 C @ 1310 & 1550nm
* PMDQ is a link of 20 cable sections (M) and a probability level of 0.01% (Q).

4. Characteristic of Optical Cable


4.1 Mechanical & environmental characteristics
4.1.1 Cable bending radius: 10 x cable diameter (during operation)
20 x cable diameter (during installation)
4.1.2 Temperature range
Operating temperature range -20oC to +60oC
Storage / Transport temperature range -40oC to +70oC
o o
Installation temperature range -10 C to +50 C

Page 4 of 6
Technical literature for Optical Fiber Cable

4.2 Main mechanical & environmental characteristics test


NO ITEM TEST METHOD ACCEPTANCE
REQUIREMENTS
1 Tensile Strength - Load: 2,000 N - Loss change 0.1 dB @1550 nm
IEC 794-1-E1 - Length of cable under load: 50m - No fiber break and no sheath
- Load time: 5min damage.

2 Crush Test - Load: 2, 000 N/100mm - Loss change 0.1 dB @1550 nm


IEC 60794-1-E3 - Load time: 1min - No fiber break and no sheath
damage.
3 Impact Test - Points of impact: 5 - Loss change 0.1 dB @1550 nm
IEC 60794-1-E4 - Times of per point: 5 - No fiber break and no sheath
- Impact energy: 2.5Nm damage.
- Radius of hammer head: 12.5mm
- Impact rate: 2sec/cycle

4 Repeated Bending - Bending Dia.: 20 x OD - Loss change 0.1 dB @1550 nm


IEC 60794-1-E6 - Load: 250N - No fiber break and no sheath
- Flexing rate: 3sec/cycle damage.
- No. of cycle: 30

5 Torsion - Length: 1m - Loss change 0.1 dB @1550 nm


IEC 60794-1-E7 - Load: 250N - No fiber break and no sheath
- Twist rate: 1min/cycle damage.
- Twist angle: 90
- No. of cycle: 10

6 Water Penetration - Height of water: 1m - No water shall have leaked from


IEC 60794-1-F5B - Sample length: 3 m the opposite end of cable
- Time: 24 hour

7 Temperature Cycling - Temperature step: - Loss change 0.1 dB @1550 nm


IEC 60794-1-F1 +20oC-40oC+60oC +20oC - No fiber break and no sheath
- Time per each step: 24 hrs damage.
- Number of cycle: 2

8 Compound Flow - Sample length: 30 cm - No compound flow


IEC 60794-1-E14 - Temp: 70C 2C
- Time: 24 hours

9 Sheath High Voltage Test - On line test - No sheath breakdown


- 9t KV (t-sheath thickness)

Page 5 of 6
Technical literature for Optical Fiber Cable

5. Packing and Marking


5.1 Packing
5.1.1 Each single length of cable shall be reeled on Fumigated Wooden Drum suitable for long
distance shipment.
5.1.2 Covered by plastic buffer sheet.
5.1.3 Sealed by strong wooden battens.
5.1.4 At least 1 m of inside end of cable will be reserved for testing.
5.1.5 Drum length
5.1.5.1 Standard drum length is 2000m3%;
5.1.5.2 Single length not less than 90% of standard length per drum shall be permitted for quantity
not exceeding 10% of the total supply;
5.1.5.3 Total quantity is at least the ordered quantity.

5.2. Drum Marking


5.2.1 Cable drum
- Manufacturer brand;
- Roll-direction arrow;
- Cable outer end position indicating arrow;
- The word OPTICAL FIBER CABLE;
- Origin, The word MADE IN CHINA;
- Caution plate indicating the correct method for loading, unloading and convey the cable;
- Other customer information such as contract no., project no., and delivery destination. (if
needed)
5.2.2 Marking plate
- Product name;
- Cable type and size;
- Drum length;
- Gross / Net weight in kilograms;
- Drum number in meters;
- Manufacturer's name;
- Manufacturing year and month;
- Project number, contract number or purchasing order number (if needed).
5.3 Cable identification documents
- Test report.

-----------End----------