Thermal overload relays are economic electromechanical protection devices for the main circuit. They offer reliable protection for motors in the event of overload or phase failure. The thermal overload relay can make up a compact starting solution together with contactors.

Uploaded by

Pak Tam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
371 views1 page

ABB Thermal Overload Relays

Thermal overload relays are economic electromechanical protection devices for the main circuit. They offer reliable protection for motors in the event of overload or phase failure. The thermal overload relay can make up a compact starting solution together with contactors.

Uploaded by

Pak Tam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

or

ot ad
M rlo on
e ti
ov tec
o General information
pr
Thermal overload relays
2 Types T, TF & TA
Application
Description Three pole devices for single and three phase motor overload
Thermal overload relays are electromechanical protection devices for the power circuit. protection. devices are either directly connected in the motor circuit,
They offer reliable protection for motors in the event of overload or phase failure. or are fed through type (current) transformer.
The thermal overload relays are three pole relays with bimetal tripping elements. The
Thermal overload relay types
motor current flows through the bimetal tripping elements and heats them directly
Directly conn ected to circuit:
and indirectly. In case of an overload (over current), the bimetal elements bend as a
T16, TF42, TA25DU, TA42DU,
result of the heating. This leads to a release of the relay and a change of the contacts

TA75DU, TA80DU, TA110DU,
switching position (95-96 / 97-98).
TA200DU
Linear transformer-fed: TA450DU

Clear indication of ratings, approval Terminals 1/L1, 3/L2, 5/L3; for direct mounting
standards, and installation requirements to contactors (TA450DU requires accessory)

Function markers included Adjustable setting range; trips at 125% setting


(Types TF & TA) value

Sealable cover (TF42 only) RESET button, manual and automatic


selectable

STOP button
Test function and ON-OFF status indication

Phase loss sensitivity per IEC/EC 60947-4-1


Auxiliary contacts
N.C. 95-96 (tripping contact)
Terminals 2/T1, 4/T2, 6/T3 N.O. 97-98 (signaling contact)

Catalog number explanation


TF42 - 20

Overload relay type Current setting range


Upper limit

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]