Trans Amf Manual
Trans Amf Manual
1.2 Warranty
EMKO Elektronik warrants that the equipment delivered is free from defects in material and workmanship.
This warranty is provided for a period of two years. The warranty period starts from the delivery date. This
warranty is in force if duty and responsibilities which are determined in warranty document and instruction
manual performs by the customer completely.
1.3 Maintenance
Repairs should only be performed by trained and specialized personnel. Cut power to the device before
accessing internal parts.
Do not clean the case with hydrocarbon-based solvents (Petrol, Trichlorethylene etc.). Use of these
solvents can reduce the mechanical reliability of the device. Use a cloth dampened in ethyl alcohol or
water to clean the external plastic case.
Introduction Brochure. ENG TRANS-AMF 01 V22 02/15
2. Installation
indekiler
A visual inspection of this product for possible damage occured during shipment is
recommended before installation. It is your responsibility to ensure that qualified mechanical
and electrical technicians install this product.
If there is danger of serious accident resulting from a failure or defect in this unit , power off
the system and seperate the electrical connection of the device from the system.
Keep the power off until all of the wiring is completed so that electric shock and trouble with
the unit can be prevented.
The unit can be programmed using the buttons and LCD display on the front panel or PC
Software.
The unit is designed for panel mounting. Fixing is by two screw fixings.
1- Insert the unit in the panel cut-out from the front.
2- Insert the fixings in the slotted at the corners of the unit and tighten the fixing screws to secure
the unit against the panel.
! During the equipment is putted in hole on the metal panel while mechanical
installation some metal burrs can cause injury on hands, you must be careful.
152mm
135mm
182mm
229mm
2
2.3 Electrical Connection
TRANS-AMF three phase connections schematic
BATTERY -
22 21
17 18 19 20
-(SCR) +
USB
MPU
!
!
1
3
FUSE-7
BATTERY +
J1939 ECUs
! 2
N
L1
L2
L3
GENERATOR
! 4
11 12 13 14 15 16
27 26 25 24 23
Configurable Analog Input-2
* * * *
Oil Sender
Temperature Sender
BY SELECTING
Configurable Analog Input-1
PARAMETERS
To Engine
Sender Common Earth
BATTERY -
*
Max. 300VV
5
Configurable Input-1
35 34 33 32 31 30 29 28
FUSE-5
Configurable Input-2
3
8A High Temperature or
1
Configurable Input-5
Generator Configurable Input-6
Contactor
Relay
G
Cabin Temperature or
Electrical interlock
Configurable Input-7
D+(W.L.)
LOAD
Charge Alt.
BATTERY +
M
Mains Fuel Or
TRANSISTOR OUTPUTS
Relay Crank Or
10
Configurable Output-2
8A
Configurable Output-3
MAX. 1 A
FUSE-3
Configurable Output-4
9
Max. 300VV
FUSE-2
8
FUSE-8 BATTERY +
42 41 40
FUSE-1
7
5A
Configurable Output-5
MAINS
5A
Configurable Output-6
L1
L2
L3
N
!
supply the right way round and battery negative should be grounded.
2- The CAN interface requires that a 120 Ohms terminator is fitted to each end of the
communications link. This termination resistor is fitted internally into the unit. So it is not
required externally. The screen is grounded at one end ONLY.
3- Screened cable must be used for connecting the Magnetic Pickup, ensuring that the
screen is grounded at one end ONLY.
4- Current transformers secondary should be grounded.
3
3. Changing And Saving Parameters Values
Operation Screen
MAINS PROGRAM
V12: 380V V1: 220V Operator setting Press the Up or
V23: 380V V2: 220V Technician setting Down buttons to
V31: 380V V3: 220V Factory adjustment
Wait for start select the section
you wish to
view/change.
When the Prog button is
pressed, the parameters
section is asked for
accessing to parameters.
4
4. Parameters
4.1 Operator Parameters
4.1.1 Mains
4.1.2 Generator
DATE & TIME SET (System->Date & time set) Min Max Default Unit
Year Year 0 99
Month Month 1 12
Day Date 1 31
Week Day of week 1 7
Hour Hour 0 23
Minute Minute 0 59
Second Second 0 59
Note:
NO / NC : Normally Open / Normally Close
NOR / PULS : Normal / Pulse
dis = disable
7
DEFAULT SETTINGS (System->Default settings) Min Max Default Unit
Save setting to def. Save setting to default YES / NO NO
Reset default sets Reset default sets YES / NO NO
Reset factory sets Reset factory sets YES / NO NO
4.2.2 Mains
MAINS VOLT LEVEL (Mains->Volt level) Min Max Default Unit
Under volt trip Mains Under Voltage 60 600 320 VV
Under volt reset Mains Under Voltage Reset 60 600 340 VV
Over volt trip Mains Over Voltage 60 600 440 VV
Over volt reset Mains Over Voltage Reset 60 600 420 VV
4.2.3 Generator
GENERATOR VOLT LEVEL (Generator->Volt level) Min Max Default Unit
Under volt shutdown Generator Under Voltage Shutdown 60(dis) 600 320 VV
Under volt prealarm Generator Under Voltage Pre-Alarm 60(dis) 600 340 VV
Under volt reset Generator Under Voltage Pre-Alarm Reset 60 600 350 VV
Over volt shutdown Generator Over Voltage Shutdown 60 600 440 VV
Over volt prealarm Generator Over Voltage Pre-Alarm 60(dis) 600 420 VV
Over volt reset Generator Over Voltage Pre-Alarm Reset 60 600 400 VV
Shutdown delay time Generator Voltage Shutdown Delay Time 0.0 10.0 1.0 Sec
9
GEN POWER LEVEL (Generator->Power level) Min Max Default Unit
Under power set Generator Under Power Set 0 9999 0 kVA
Under power prealarm Generator Under Power Pre-Alarm 0(dis) 9999 dis kVA
Under power reset Generator Under Power Pre-Alarm Reset 0 9999 5 kVA
Under power act. Generator Under Power Actions 0(dis) 3 0(dis)
0 - Disable
1 - Warning (Alarm Only, No Shutdown)
2 - Electrical Trip (Alarm/Off Load Generator
Followed By Shutdown After Cooling)
3 - Shutdown (Alarm And Shutdown)
Under act. delay time Generator Under Power Action Delay Time 0 99 2 Sec
Over power set Generator Over Power Set 0 9999 0 kVA
Over power prealarm Generator Over Power Pre-Alarm 0(dis) 9999 dis kVA
Over power reset Generator Over Power Pre-Alarm Reset 0 9999 0 kVA
Over power act. Generator Over Power Actions 0(dis) 3 0(dis)
0 - Disable
1 - Warning (Alarm Only, No Shutdown)
2 - Electrical Trip (Alarm/Off Load Generator
Followed By Shutdown After Cooling)
3 - Shutdown (Alarm And Shutdown)
Over act. delay time Generator Over Power Action Delay Time 0 99 2 Sec
Reverse power set Reverse Power Set -9999 0 0 kW
Reverse power act. Reverse Power Actions 0(dis) 3 0(dis)
0 - Disable
1 - Warning (Alarm Only, No Shutdown)
2 - Electrical Trip (Alarm/Off Load Generator
Followed By Shutdown After Cooling)
3 - Shutdown (Alarm And Shutdown)
Rv.pow.act.delay time Reverse Power Action Delay Time 0 99 2 Sec
10
4.2.4 Engine
11
CANBUS ECU (Engine->CanBus ECU) Min Max Default Unit
Baud rate Baud Rate: 0 7 4 kBaud
0 - 20
1 - 50
2 - 100
3 - 125
4 - 250
5 - 500
6 - 800
7 - 1.000
J1939 ECU type J1939 ECU Type Selection: 0(dis) 13 0
0 - Disable
1 - Standard
2 - Volvo EMS1
3 - Volvo EMS2
4 - Volvo EMS2b
5 - Volvo EDC3
6 - Volvo EDC4
7 - Deutz EMR2
8 - Deutz EMR3
9 - Perkins 1300
10 - Perkins ADEM3
11 - Perkins ADEM4
12 - Scania S6
13 - MAN MFR
Device address Device Address 0 255 17
SPN version SPN version 1 3 1
ECU remote control ECU Remote Control via J1939 ENABL/DISBL ENABL
Speed control enable Speed Control via J1939 ENABL/DISBL ENABL
Oil pres cont. enab Oil Pressure Control via J1939 ENABL/DISBL DISBL
Temp. control enable Coolant Temperature Control via J1939 ENABL/DISBL DISBL
Speed set point Speed Set Point Selection 1500 / 1800 1500 RPM
Speed correction Speed Correction Value 0 100 50 %
Red stop delay J1939 Red Stop Lamp Delay 0 250 2 Sec
16
Conf. AI1 high shutd. Configurable Analog Input-1 0 (dis) 3000 0 (dis) %
High Shutdown
Conf. AI1 control ON Configurable Analog Input-1 0 (dis) 3000 0 (dis) %
control ON
Conf. AI1 control OFF Configurable Analog Input-1 0 3000 75 %
control OFF
Conf. AI2 unit Configurable Analog Input-2 Unit BAR/PSI/KPA/C/F/%/Lt C
Conf. AI2 type Configurable Analog Input-2 Type 0 - Not Used (Disable) 0 (dis)
1 - Digital NC
2 - Digital NO
3 - VDO 120 C
4 - VDO 150 C
5 - DATCON
6 - MURPHY
7 - PT100
8 - User Configured
Conf. AI2 low prealrm Configurable Analog Input-2 0 (dis) 300 0 (dis) C
Low Pre-Alarm
Conf. AI2 low reset Configurable Analog Input-2 0 300 60 C
Low Reset
Conf. AI2 low shutdwn Configurable Analog Input-2 0 (dis) 300 0 (dis) C
Low Shutdown
Conf. AI2 high prealr Configurable Analog Input-2 0 (dis) 300 0 (dis) C
High Pre-Alarm
Conf. AI2 high reset Configurable Analog Input-2 0 300 90 C
High Reset
Conf. AI2 high shutd. Configurable Analog Input-2 0 (dis) 300 0 (dis) C
High Shutdown
Configurable Analog Input-2 0 (dis) 300 0 (dis) C
Conf. AI2 control ON
control ON
Configurable Analog Input-2 0 300 75 C
Conf. AI2 control OFF
control OFF
18
Conf. AI1 sender 6 Configurable Analog Input-1 Sender Point-6 0 1300 110 R
Conf. AI1 value 6 Configurable Analog Input-1 Point-6 0 3000 55 %
Conf. AI1 sender 7 Configurable Analog Input-1 Sender Point-7 0 1300 130 R
Conf. AI1 value 7 Configurable Analog Input-1 Point-7 0 3000 66 %
Conf. AI1 sender 8 Configurable Analog Input-1 Sender Point-8 0 1300 150 R
Conf. AI1 value 8 Configurable Analog Input-1 Point-8 0 3000 77 %
Conf. AI1 sender 9 Configurable Analog Input-1 Sender Point-9 0 1300 170 R
Conf. AI1 value 9 Configurable Analog Input-1 Point-9 0 3000 88 %
Conf. AI1 sender 10 Configurable Analog Input-1 Sender Point-10 0 1300 190 R
Conf. AI1 value 10 Configurable Analog Input-1 Point-10 0 3000 100 %
Conf. AI2 sender 1 Configurable Analog Input-2 Sender Point-1 0 1300 579 R
Conf. AI2 value 1 Configurable Analog Input-2 Point-1 0 300 28 C
Conf. AI2 sender 2 Configurable Analog Input-2 Sender Point-2 0 1300 404 R
Conf. AI2 value 2 Configurable Analog Input-2 Point-2 0 300 35 C
Conf. AI2 sender 3 Configurable Analog Input-2 Sender Point-3 0 1300 342 R
Conf. AI2 value 3 Configurable Analog Input-2 Point-3 0 300 40 C
Conf. AI2 sender 4 Configurable Analog Input-2 Sender Point-4 0 1300 250 R
Conf. AI2 value 4 Configurable Analog Input-2 Point-4 0 300 50 C
Conf. AI2 sender 5 Configurable Analog Input-2 Sender Point-5 0 1300 179 R
Conf. AI2 value 5 Configurable Analog Input-2 Point-5 0 300 60 C
Conf. AI2 sender 6 Configurable Analog Input-2 Sender Point-6 0 1300 136 R
Conf. AI2 value 6 Configurable Analog Input-2 Point-6 0 300 70 C
Conf. AI2 sender 7 Configurable Analog Input-2 Sender Point-7 0 1300 103 R
Conf. AI2 value 7 Configurable Analog Input-2 Point-7 0 300 80 C
Conf. AI2 sender 8 Configurable Analog Input-2 Sender Point-8 0 1300 77 R
Conf. AI2 value 8 Configurable Analog Input-2 Point-8 0 300 90 C
Conf. AI2 sender 9 Configurable Analog Input-2 Sender Point-9 0 1300 67 R
Conf. AI2 value 9 Configurable Analog Input-2 Point-9 0 300 95 C
Conf. AI2 sender 10 Configurable Analog Input-2 Sender Point-10 0 1300 63 R
Conf. AI2 value 10 Configurable Analog Input-2 Point-10 0 300 98 C
19
CONF. INPUT-X (Inputs->Conf. input-x) Min Max Default Unit
Dis,user conf.or list 0- Disable 0(dis) 2 in2,in1=2
3=1
1- User Configured in4, 5=2
2- Select From List in6=1
Polarity 0- Normally Open (Close To Activate) 0 1 in1, 3=1
in2, 4=0
1- Normally Close (Open To Activate) in5, 6=0
Indication If User Configured 0 4 in1=0
in2=0
0- Status in3=4
1- Warning Non-Latching in4=0
2- Warning Latching in5=0
3- Electrical Trip in6=0
4- Shutdown
Activation If User Configured 0 2 in1, 2=2
in3, 4=2
0- Active From Starting in5, 6=2
1- Active From Safety On
2- Always Active
Select from list If Select From List 0 in1=26 in1=25
0-Remote Start On Load in2=24 in2=3
in3=24 in3=4
1-Remote Start Off Load in4=26 in4=25
2-Auxiliary Mains Fail in5=25 in5=25
3-Simulate Lamp Test Button in6=24 in6=7
4-Simulate Horn Reset Button
5-Simulate Alarm Reset Button
6-Simulate Auto Button
7-Simulate Test Button
8-Simulate Manual Button
9-Simulate Start Button
10-Simulate Stop Button
11-Generator Closed Auxiliary
12-Generator Load Inhibit
13-Mains Closed Auxiliary
14-Mains Load Inhibit
15-Auto Restore Inhibit
16-Auto Start Inhibit
17-Panel Lock
18-Scheduled Runs(Exercise) Inhibited
19-Priority Select
20-Transfer To Generator/Open Mains
21-Transfer To Mains/Open Generator
22-Remote Inhibit
23-Being Found Alive
24-Generator is loaded in stop mode
25 - Emergency Stop (for only input-1)
25 - Low Oil Pressure (for only input-4)
25 - High Temperature (for only input-5)
26 - Low Oil Level (for only input-4)
26 - Emergency Stop No-Latching (for only input-1)
Active delay Input active delay 0 250 in1=0 Sec
in2, 3=5
in4, 5=0
in6=5
20
CONF. INPUT-7 (Inputs->Conf. input-7) Min Max Default Unit
Input type 0- Disable 0(dis) 3 3
1- User Configured (Digital)
2- Select From List (Digital)
3- Cabin Temperature (Anolog)
Polarity If Input Type is Digital 0 1 0
0- Normally Open (Close To Activate)
1- Normally Close (Open To Activate)
Indication If Input Type is User Configured 0 4 0
0- Status
1- Warning Non-Latching
2- Warning Latching
3- Electrical Trip
4- Shutdown
Activation If Input Type is User Configured 0 2 2
0- Active From Starting
1- Active From Safety On
2- Always Active
Select from list If Input Type is Select From List 0 24 8
0-Remote Start On Load
1-Remote Start Off Load
2-Auxiliary Mains Fail
3-Simulate Lamp Test Button
4-Simulate Horn Reset Button
5-Simulate Alarm Reset Button
6-Simulate Auto Button
7-Simulate Test Button
8-Simulate Manual Button
9-Simulate Start Button
10-Simulate Stop Button
11-Generator Closed Auxiliary
12-Generator Load Inhibit
13-Mains Closed Auxiliary
14-Mains Load Inhibit
15-Auto Restore Inhibit
16-Auto Start Inhibit
17-Panel Lock
18-Scheduled Runs(Exercise) Inhibited
19-Priority Select
20-Transfer To Generator/Open Mains
21-Transfer To Mains/Open Generator
22-Remote Inhibit
23-Being Found Alive
24-Generator is loaded in stop mode
Active delay Input active delay (If Input Type is Digital) 0 250 5 Sec
Cabin temp.low prealr Cabin temperature low prealarm -50(dis) 100 dis C
Cabin temp.low reset Cabin temperature low prealarm reset -50 100 0 C
Cabin temp.low shutd. Cabin temperature low shutdown -50(dis) 100 dis C
Cabin temp.high preal Cabin temperature high prealarm reset -50(dis) 100 dis C
Cabin temp.high reset Cabin temperature high prealarm -50 100 0 C
Cabin temp.high shutd Cabin temperature high shutdown -50(dis) 100 dis C
Note-1 : x = 1(exp. input-1), 2(exp. input-2), 3(exp. input-3), 4(exp. input-4), 5(exp. input-5), 6(exp.
input-6), 7(exp. input-7) or 8(exp. input-8)
Note-2 : dis = disable
22
4.2.6 Outputs
CONF. OUTPUT-1 (Outputs->Conf. output-1) Min Max Default Unit
Polarity 0- Normally Open (Close To Activate) 0 1 0
1- Normally Close (Open To Activate)
0-NOT USED
Function 1-AIR FLAP CONTROL 0 131 43
2-ALARM RESET
3-AUDIBLE ALARM
4-AUTO START INHIBIT
5-AUXILIARY MAINS FAILURE
6-BATTERY HIGH VOLTAGE
7-BATTERY LOW VOLTAGE
8-CALLING FOR SCHEDULED RUN(EXERCISE)
9-CAN ECU POWER
10-CAN ECU STOP
11-CHARGE ALTERNATOR FAILURE
12-COMMON ALARM
13-COMMON ELECTRICAL TRIP ALARM
14-COMMON SHUTDOWN ALARM
15-COMMON WARNING ALARM
16-COOLING FAN AFTER START
17-COOLING FAN AFTER STOP
18-COOLANT TEMPERATURE HIGH PRE-ALARM
19-COOLANT TEMPERATURE HIGH SHUTDOWN
20-COOLING DOWN TIMER IN PROGRESS
21-CRANK RELAY ENERGISED
22-DELAYED ALARMS ACTIVE
23-DIGITAL INPUT1 ALARM
24-DIGITAL INPUT2 ALARM
25-DIGITAL INPUT3 ALARM
26-DIGITAL INPUT4 ALARM
27-DIGITAL INPUT5 ALARM
28-DIGITAL INPUT6 ALARM
29-DIGITAL INPUT7 ALARM
30-EXPANSION INPUT1 ALARM
31-EXPANSION INPUT2 ALARM
32-EXPANSION INPUT3 ALARM
33-EXPANSION INPUT4 ALARM
34-EXPANSION INPUT5 ALARM
35-EXPANSION INPUT6 ALARM
36-EXPANSION INPUT7 ALARM
37-EXPANSION INPUT8 ALARM
38-EARTH FAULT
39-EMERGENCY STOP
40-FAIL TO START ALARM
41-FAIL TO STOP ALARM
42-CONF. AI1 CONTROL
43-FUEL RELAY ENERGISED
44-GAS ENGINE IGNITION OUTPUT
45-GENERATOR AT REST
46-GENERATOR AVAILABLE
47-GENERATOR CLOSED AUXILIARY
48-GENERATOR FAILED TO CLOSE
49-GENERATOR FAILED TO OPEN
50-GENERATOR HIGH FREQUENCY PRE-ALARM
51-GENERATOR HIGH FREQUENCY SHUTDOWN
52-GENERATOR HIGH VOLTAGE PRE-ALARM
53-GENERATOR HIGH VOLTAGE SHUTDOWN
54-GENERATOR LOAD INHIBIT
55-GENERATOR LOW FREQUENCY PRE-ALARM
56-GENERATOR LOW FREQUENCY SHUTDOWN
57-GENERATOR LOW VOLTAGE PRE-ALARM
58-GENERATOR LOW VOLTAGE SHUTDOWN
59-GENERATOR STOPPING
60-GENERATOR OPEN BREAKER
61-HORN OUTPUT LATCHED
62-HORN OUTPUT PULSED
63-LAMP TEST
64-CONF. AI2 CONTROL
65-LOSS OF MAGNETIC PICK-UP SPEED SIGNAL
66-LOW TEMPERATURE
67-MAINTENANCE DUE ALARM
68-MAINS CLOSED AUXILIARY
69-MAINS FAILED TO CLOSE
70-MAINS FAILED TO OPEN
71-MAINS FAILURE
72-MAINS HIGH FREQUENCY
73-MAINS HIGH VOLTAGE
74-MAINS LOAD INHIBIT
75-MAINS LOW FREQUENCY
76-MAINS LOW VOLTAGE
77-MAINS OPEN BREAKER
78-NO LOADING COMMAND
79-OIL PRESSURE LOW PRE-ALARM
80-OIL PRESSURE LOW SHUTDOWN
81-CONF.AI1.HIGH PREA
82-CONF.AI1.HIGH SHUT
83-OVER CURRENT PRE-ALARM
84-OVER CURRENT
85-OVER POWER PRE-ALARM
86-OVER POWER SHUTDOWN
87-OVERSPEED PRE-ALARM
88-OVERSPEED SHUTDOWN
89-PANEL LOCK
90-PRE-HEAT(during preheat timer)
91-PRE-HEAT(until end of cranking)
92-PRE-HEAT(until end of warming)
93-PRE-HEAT(until end safety on)
94-REMOTE START PRESENT
95-REMOTE STOP DELAY IN PROGRESS
96-SHORT CIRCUIT
97-SMOKE LIMITING
98-STARTING ALARM
99-STARTING ALARMS ARMED
100-STOP RELAY ENERGISED
101-SYSTEM IN AUTO MODE
102-SYSTEM IN MANUAL MODE
103-SYSTEM IN STOP MODE
104-SYSTEM IN TEST MODE
105-UNDER CURRENT PRE-ALARM
106-UNDER CURRENT
107-UNDER POWER PRE-ALARM
108-UNDER POWER SHUTDOWN
109-UNDERSPEED PRE-ALARM
110-UNDERSPEED SHUTDOWN
111-WAITING FOR GENERATOR
112-DUAL COMMUNICATION ERROR
113-LOAD SUPPLY FROM GENERATOR
114-LOAD SUPPLY FROM MAINS
115-CONFIGURABLE ANALOG INPUT 1 LOW PRE-ALARM
116-CONFIGURABLE ANALOG INPUT 1 LOW SHUTDOWN
117-CONFIGURABLE ANALOG INPUT 2 LOW PRE-ALARM
118-CONFIGURABLE ANALOG INPUT 2 LOW SHUTDOWN
119-CONFIGURABLE ANALOG INPUT 2 HIGH PRE-ALARM
120-CONFIGURABLE ANALOG INPUT 2 HIGH SHUTDOWN
121-CHOKE ACTIVE
122-REMOTE CONTROL ACTIVE
123-REVERSE POWER
124-CABIN TEMPERATURE LOW PRE-ALARM
125-CABIN TEMPERATURE LOW SHUTDOWN
126-CABIN TEMPERATURE HIGH PRE-ALARM
127-CABIN TEMPERATURE HIGH SHUTDOWN
128-HEATER CONTROL
129-REMOTE OUTPUT
130-UNBALANCE LOAD
131-WATER PUMP
23
CONF. OUTPUT-2 (Outputs->Conf. output-2) Min Max Default Unit
Polarity 0- Normally Open (Close To Activate) 0 1 0
1- Normally Close (Open To Activate)
Function The same as Configurable Output-1 options 0 131 21
CONF. EXP. OUTPUT-1 (Outputs->Conf. exp. output-1) Min Max Default Unit
Polarity 0- Normally Open (Close To Activate) 0 1 0
1- Normally Close (Open To Activate)
Function The same as Configurable Output-1 options 0 131 12
CONF. EXP. OUTPUT-2 (Outputs->Conf. exp. output-2) Min Max Default Unit
Polarity 0- Normally Open (Close To Activate) 0 1 0
1- Normally Close (Open To Activate)
Function The same as Configurable Output-1 options 0 131 12
CONF. EXP. OUTPUT-3 (Outputs->Conf. exp. output-3) Min Max Default Unit
Polarity 0- Normally Open (Close To Activate) 0 1 0
1- Normally Close (Open To Activate)
Function The same as Configurable Output-1 options 0 131 12
CONF. EXP. OUTPUT-4 (Outputs->Conf. exp. output-4) Min Max Default Unit
Polarity 0- Normally Open (Close To Activate) 0 1 0
1- Normally Close (Open To Activate)
Function The same as Configurable Output-1 options 0 131 12
CONF. EXP. OUTPUT-5 (Outputs->Conf. exp. output-5) Min Max Default Unit
Polarity 0- Normally Open (Close To Activate) 0 1 0
1- Normally Close (Open To Activate)
Function The same as Configurable Output-1 options 0 131 12
CONF. EXP. OUTPUT-6 (Outputs->Conf. exp. output-6) Min Max Default Unit
Polarity 0- Normally Open (Close To Activate) 0 1 0
1- Normally Close (Open To Activate)
Function The same as Configurable Output-1 options 0 131 12
24
CONF. EXP. OUTPUT-7 (Outputs->Conf. exp. output-7) Min Max Default Unit
Polarity 0- Normally Open (Close To Activate) 0 1 0
1- Normally Close (Open To Activate)
Function The same as Configurable Output-1 options 0 131 12
CONF. EXP. OUTPUT-8 (Outputs->Conf. exp. output-8) Min Max Default Unit
Polarity 0- Normally Open (Close To Activate) 0 1 0
1- Normally Close (Open To Activate)
Function The same as Configurable Output-1 options 0 131 12
4.2.7 Timers
START TIMERS (Timers->Start timers) Min Max Default Unit
Mains transient delay Mains Transient Delay 0.0 20.0 2.0 Sec
Mains fail start dely Mains Fail Start Delay 0 9999 0 Sec
Remote start delay Remote Start Delay 0 3600 4 Sec
Pre-heat Pre-Heat 0 250 3 Sec
Pre-heat bypass Pre-Heat Bypass 0 250 0 Min
Safety on delay Safety On Delay 0 99 5 Sec
Warming up time Warmup Time 0 250 3 Sec
Horn duration Horn Duration 0 (dis) 999 60 Sec
Chg. excitation time Charge Excitation Time 0 99(cont) 15 Sec
Cooling fan time Cooling Fan Time 0 250 180 Sec
Idle mode time Idle Mode Time (Smoke Limiting) 0 (dis) 3600 dis Sec
Idle mode time off Idle Mode Time Off (Smoke Limiting Off) 0 250 5 Sec
DIAL-UP & ETHERNET (Expansion modules->Dial-up & Ethernet) Min Max Default Unit
Disable/enable select Expansion Dal-up&Ethernet Module Selection ENABL/DISBL ENABL
Call back selection Call Back Selection ENABL/DISBL DISBL
WEB SERVER MODULE (Expansion modules->Web Server) Min Max Default Unit
Disable/enable select Web Server Module Selection ENABL/DISBL ENABL
GPRS WEB MODULE (Expansion modules->GPRS Web) Min Max Default Unit
Disable/enable select GPRS-Web Module Selection ENABL/DISBL ENABL
GEN. VOLTAGE OFFSET (User adjustment->Gen. voltage offset) Min Max Default Unit
Gen. V1 offset Generator V1 Offset -20 20 0 VV
Gen. V2 offset Generator V2 Offset -20 20 0 VV
Gen. V3 offset Generator V3 Offset -20 20 0 VV
SENDER INPUTS OFFSET (User adjustment->Sender inputs offset) Min Max Default Unit
Oil Pressure offset Oil Pressure Offset -2.0 2.0 0.0 BAR
Temperature offset Coolant Temperature Offset -20 20 0 C
Conf. AI1 offset Configurable Analog Input-1 Offset -200 200 0 %
Conf. AI2 offset Configurable Analog Input-2 Offset -20 20 0 C
Thank you very much for your preference to use Emko Elektronik
products, please visit our web page to download detailed user
Your Technology Partner manual. www.emkoelektronik.com.tr
28