4-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT Enhanced Sidelobe Suppression
4-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT Enhanced Sidelobe Suppression
4-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT Enhanced Sidelobe Suppression
Mechanical specifications
1)
4)
Remarks Weight approx. Units per
Type No. Description
mm | inches kg | lb antenna
1636 | 64.4
1494 | 58.8
1436 | 56.5
1389 | 54.7
For downtilt mounting use the clamps for an appropriate mast diameter together with the downtilt kit.
Wall mounting: No additional mounting kit needed.
Grounding: The metal parts of the antenna including the mounting kit and the inner
conductors are DC grounded.
Correlation Table
Adjustment
Frequency range Array Connector mechanism
with integrated long neck
1710 2200 MHz B1 12 scale
1710 2200 MHz B2 34 1) 20 | 0.8
5)
2) 72 | 2.8
3) 64 | 2.5
4) 9 | 0.4
5) 35 42 | 1.4 1.7
B1 B2
Left Right
Layout of interface:
254 | 10.0
48 | 1.9
71 | 2.8
41 | 1.6
98 | 3.9
Subject to alteration.
323 | 12.7
936.4894/a
Bottom view
All dimensions in mm | inches
Environmental Kathrein cellular antennas are designed to operate under the environmental conditions
conditions: as described in ETS 300 019-1-4 class 4.1 E.
The antennas exceed this standard with regard to the following items:
Low temperature: 55 C
High temperature (dry): +60 C
For antennas equipped with FlexRET: The electrical downtilt adjusting is designed to
operate under the environmental conditions as described in the valid data sheet of the
FlexRET.
Ice protection: Due to the very sturdy antenna construction and the protection of
the radiating system by the radome, the antenna remains operational even under icy
conditions.
Environmental Kathrein antennas fulfil the stated specifications after completion of the environmental
tests: tests as defined in ETS 300 019-2-4. The homogenous design of Kathreins antenna
families uses identical modules and materials.
Extensive tests have been performed on typical samples and modules. The vibration
test has been adapted relating to frequency and acceleration to the conditions of mast
mounted antennas.
Please note: As a result of more stringent legal regulations and judgements regarding product
liability, we are obliged to point out certain risks that may arise when products are
used under extraordinary operating conditions.
The details given in our data sheets have to be followed carefully when installing
the antennas and accessories.
Site planning and installation must be carried out by qualified and experienced
staff. All relevant national safety regulations must be upheld and respected.
Incorrect site planning, faulty installation, as well as interfering surroundings
on site, may lead to deviations in the electrical parameters compared to those
specified in the respective data sheets.
The connectors on this product are only suitable for connecting to the compatible
counterpart. Please ensure that the connected cable has been fitted with a
Subject to alteration.
Our quality assurance system and our Our products are compliant to the
environmental management system apply EU Directive RoHS as well as to other
to the entire company and are certified RoHS environmentally relevant regulations
936.4694/b
Torque MA = G
Torque:
M8 => MA = 20 Nm
M6 => MA = 8 Nm
A B C D E F G H
152 mm 40 mm 40 mm 50 115 mm 93 mm 18 26 mm 20 Nm 125 mm
Washer
Subject to alteration.
936.4123
1
2
2
Adjustment wheel with twist-lock Thread for fixing the protective To set the downtilt angle exactly,
function. cap or the RCU (Remote Control you must look horizontally at the
Downtilt spindle with integrated Unit). scale. The lower edge of the gear-
scale. Gearwheel for RCU power drive. wheel must be used for alignment.
0 max.
max. 0
Remove the protective cap. Set downtilt angle by rotating the Screw on the protective cap again.
adjustment wheel.
For a description of RCU installation please refer to the respective data sheet.
4 3
2 1
There are four interfaces for feeding the antenna The connectors are mounted at two levels in order to facilitate feederline
located at the bottom. installation.
Start with the rearside located inter- After feederline installation the optional For a full description of RCU installation
face no. 1. remote control units (RCU) can be please refer to the respective data sheet.
mounted if required.
Place the connector carefully and fix the
nut using a torque-wrench (according to
the manufacturers guidelines).
Subject to alteration.
Please note: Additional weather sealing of correctly installed feederline connector interfaces is not required,
nor is it recommended by the connector manufacturers.