Brochure UPS en in
Brochure UPS en in
Brochure UPS en in
www.deltapowersolutions.com
Contents
Delta Group 1
About MCIS 3
Delta UPS 4
Product 6
Agilon & Amplon
Ultron & Modulon
Product Application Matrix
UPS Management
Technical Specifications 32
UPS Q&A 42
1
Introduction
Delta Group
Delta Group is the worlds leading provider of power management and thermal management solutions, as well as
a major source for components, visual displays, industrial automation,networking products, and renewable energy
solutions. Delta Group is focused on three main businesses: power electronics,energy management, and smart green
life. Delta Group has sales offices worldwide and manufacturing plants in Taiwan, China, Thailand, Japan, Mexico,
India, Brazil and Europe.
As a global leader in power electronics, Deltas mission is,To provide innovative, clean and energy-efficient solutions
for a better tomorrow. Delta is committed to environmental protection and has implemented green, lead-free
production and recycling and waste management programs for many years.
2
About MCIS
With its expertise and experience in power management and energy efficiency , the Mission Critical Infrastructure
Solutions (MCIS) business of Delta Electronics Inc. positions itself as:The power behind competitiveness. MCIS
plays an important role in making our customers businesses more competitive. We fulfill this role by providing highly
reliable and efficient power management products and datacenter infrastructure solutions to ensure the continuity of
our customers mission critical operations while reducing their Total Cost of Ownership (TCO). Delta MCIS is a powerful
and trustworthy partner to companies that strive to outperform the competition.
With more than 15 years of experience in the UPS industry, Delta Electronics is a leading brand, commanding a market
share ranked top 10 in the market and featuring complete professional capacities ranging from product development,
design and manufacturing for all UPS product lines. Our client base covers world class enterprises in the areas of
semiconductors, optoelectronics, food processing, finance, petrochemicals and telecommunications. Additionally, our
UPS solutions have been adopted extensively at major Asia events in recent years, including the World Expo 2010
Shanghai, the Guangzhou Asian Games and Universiade Shenzhen, just to name a few. Deltas UPS solutions play
a critical role in power management for a number of public mega projects, including the Taipei Mass Rapid Transit
System, that has been rated number one in reliability by Nova/CoMet five years in a row since 2004; the Russia
Railway Control System, that controls the operations of the second longest railway system in the world (85,500 km);
and the recently launched Tiangong-1 Spacecraft in China. The most competitive companies in the world choose Delta
because our products are designed to enhance competitiveness.
3
Introduction
Delta UPS
Our clients are most concerned about power issues such as power failure, power sag, power surge, under voltage
or over voltage, frequency variation, harmonic distortion and line noise. Delta Electronics emphasizes the areas of
redundant power supply, voltage regulation, equipment protection and adjustment and has designed and developed
four UPS product families - Agilon, Amplon, Ultron and Modulon. Their power range, applications and the equipment
they protect are listed below:
ProductFamily Power Topology Applications
Agilon Under 1kVA Single-Phase UPS PC and Peripherals
Amplon 1kVA or higher Single-Phase UPS Server and Network Equipment
Ultron 15kVA or higher Three-Phase On-Line UPS Datacenter and Industrial Equipment
Modular. Unit expansion and Redundant power
Modulon 20kVA or higher Three-Phase modular On-Line UPS
supply can be achieved within a single rack.
4
Customers can choose suitable UPS systems based on their needs to maintain seamless operations and ensure their
long term competitiveness.
Agilon Family
In the Delta UPS product line, the Agilon family are single phase UPS systems for power rating requirements under
1kVA, that can support PC products, peripherals and small POS systems. The word Agilon (Agile + on), denotes
agility and precision, which describe the features of this UPS system small yet efficient; they are the perfect power
management solution for residential users, SOHO workers or small enterprises.
Amplon Family
In the Delta UPS product line, the Amplon family are single phase UPS systems for power rating requirements above
1kVA that support medium to small network devices, security and surveillance systems and POS systems. The word
Amplon (Ample + on), represents ample stability, which describes this UPS system it maximizes space and economic
benefits. Amplon systems are the perfect power management solution for small to medium enterprises, such as
financial institutes, government departments and medical centers, and offer the power protection solution with the
highest space and cost benefits.
Ultron Family
In the Delta UPS product line, the Ultron family are three-phase UPS systems for power rating requirements above
15kVA that support mission critical applications including industrial equipment, datacenters, traffic control facilities,
broadcast stations and backbone networks. The word Ultron (Ultra + on), signifies ultimate performance, which
describes the features of this UPS system outstanding stability and insurance for mission critical applications.
Modulon Family
In the Delta UPS product line, the Modulon family features a three-phase modularization architecture for power rating
requirements above 20kVA and supports datacenters, mid-large network equipments, data storage centers and
financial balance centers. The word Modulon (Modular + on) highlights its core feature modularization. Customers
can purchase UPS systems with greater flexibility based on their initial unit needs and future needs for scalability to
lower their TCO and maximize system benefits.
5
Product
Features:
Applications: Wide input voltage range reduces battery discharging
occurrences and prolongs battery life.
Automatic voltage regulation (AVR) delivers stable voltage
and provides higher availability.
PC Fax Monitor
Smart charger shortens battery recharging time.
Battery-start function when utility power is not present.
UPS is able to restart automatically while utility power is
recovering.
ADSL Home POS Automatic battery charging in off mode.
Appliances
LED indicators provide the UPS status at a glance.
Audible alarms provide indication of UPS and utility power
conditions.
Automatic self-test ensures battery condition.
Provides 24/7 protection from surges, lightning and other
power events.
Equipped with network line RJ45 surge protection.
Overload and over-charge protection.
Surge protection outlet for less-essential equipment.
Well-designed microprocessor control provides higher
reliability.
6
Delta UPS - Amplon Family
Features:
Double-conversion technology provides 24/7 full-time
protection.
Applications:
Automatic input frequency (50 or 60 Hz) Auto-detection.
AC-start and battery-start capabilities.
Input voltage bears up to 330 Vac. Suitable for severe utility
Server Network Security conditions.
High charging capability increases availability.
Suitable for long backup time applications with customized
battery source.
Medical POS Banking Optional external battery pack for longer backup time.
Smart slot for mission critical applications.
High input power factor (pf > 0.97) saves installation costs.
Wide input voltage range and stable power supply extends
battery lifetime.
7
Product
Features:
Double-conversion technology provides 24/7 full-time
Applications: protection.
Battery-start capability without utility power.
Automatic bypass ensures continuous output power when
fault occurs.
Server Network Security
Automatic input frequency detection.
Optional external battery pack for longer backup time.
RS232 port with power management software.
Wide input voltage range reduces battery discharging
Medical POS Banking
occurrence and prolongs battery lifetime.
Intelligent management prevents battery from over-
discharge.
8
Delta UPS - Amplon Family
Features:
Applications:
Double-conversion technology provides 24/7 full-time
protection.
Automatic input frequency detection.
Server Telecom Industrial Additional charger board can be added to reduce
recharging time.
AC-start and battery-start capabilities.
Rail kit is included in the package.
Rack or tower configuration in 2U size cabinet.
Network VolP Storage
Fulfill long backup time demand for mission critical
applications.
Remote management over network via software.
High input power factor (pf > 0.97) saves installation cost.
Medical
Wide input voltage range reduces battery discharging
occurrence and prolongs battery lifetime.
9
Product
Features:
Double-conversion technology.
Data Center Telecom Industrial In-built galvanic isolation transformer
Automatic input frequency.
AC-start and battery-start capabilities
Comprehensive LC Display for monitoring of all UPS
Parameters and operating mode / status
Network Security Lab Suitable for severe utility conditions (Commercial,
Residencial & Rural sites)
High recharging capability increases availability.
Suitable for short (in-built batteries) as well as long (external batteries)
backup
Medical Metro Additional in-built battery charging capabilities upto 12A
Smart slot to support Mini SNMP /Mini ModBus /Mini Relay I/O
Interface for mission critical applications
In-built maintenance bypass switch for online maintenance in
Addision to static bypass (automatic)
Option of Air filters for dusty environment.
High input power factor (IPF> 0.97) and low iTHD saves
on installation cost
Wide input voltage range and stable power supply extends
battery life
High energy efficiency saves on operative cost and
electricity bill.
10
Delta UPS - Amplon Family
5/6/10 kVA
The Amplon RT series delivers double-conversion on-line
technology, high power density and input power factor,
and low current harmonics with its advanced architecture.
Designed in a rack or tower configuration with an LCD
display, Amplon RT offers advanced performance for servers,
data centers, networking, VoIP and telecommunications.
The Amplon RT has 1+1 parallel redundancy function to
provide higher reliability. Optional external battery pack can
be added to fulfill longer backup time for mission critical
applications.
Applications: Features:
True online double-conversion topology provides 24/7 full-
time protection.
1+1 parallel redundancy or expansion without requiring
Server Telecom Industrial
additional hardware.
AC-start and battery-start capabilities.
Additional charger board can be added to reduce
recharging time.
Network VolP Storage Optional maintenance bypass box for parallel redundancy
with manual bypass switch.
External charger box enhances battery charging ability.
Rack or tower configuration.
Medical Multi-language LCD display with blue backlight.
Optional external battery pack for longer backup time.
Output factor 0.9 delivers more real power.
High input power factor (pf > 0.99) and low harmonic
distortion (iTHD < 5%).
Common battery installation enables two UPS in parallel to
share one battery source for cost savings.
Wide input voltage range reduces battery discharging
occurrence and prolongs battery lifetime.
11
Product
11 kVA
Delta Amplon J Series is a futuristic design using True
Online Double Conversion topology (VFI). This UPS comes
with highest power density and Rotating LCD Display for easy
Rack or Tower convertibility.
Features:
True online double conversion topology provides 24*7 ful time protections
Smart Economy Mode: operation results in greater energy saving using
energy optimizer for lesser critical applications
Dual Feed Input allows installation of two independent power sources
with option of Hot Standby to provide redundancy.
Remote Emergency Power Off (REPO) for remote shutdown in case
of emergency.
Programmable front panel Interface allows user to set up important
functions like Output Parameters & Mode of operation.
Lightning and Surge Protection is a superior to separate surge suppressors
Server Telecom Industrial Alarms & Indications provide real time parameters on the LCD Display
reducing resolution time by 70%.
SNMP Management Capability: Enables to monitor and control remote
UPSs from Web browser
Input Power Factor Correction up to unity reduces input current resulting in low
electricity bills.
Network VolP Storage
High AC to AC Efficiency with load dependent fan speed technique results in
lower running costs
Widest Input Voltage Range to operate on mains mode at voltages as low as
120V (single phase) 280V (three phase) to provide conditioned supply during
Medical long brownout conditions
Smallest Footprint: Our R&D centers have developed design using advancements
in micro-computing techniques and power devices delivering smallest footprint.
12
Delta UPS Ultron Family
Features:
Independent bypass input system supports hot standby
installation for higher reliability.
Applications:
Internal automatic bypass offers sustainable power to loads
while UPS fault.
3p-3p and 3p-1p models are available.
Data Center Telecom Industrial Multi-connectivity with power management software.
Inbuilt manual bypass switch for maintenance safety.
Remote and local emergency power off functions.
Optional external battery cabinet for longer backup time.
Network Security Lab High input power factor saves installation cost.
97% high efficiency in economy mode saves energy and
operating cost.
Wide input voltage range reduces battery discharging
occurrence and prolongs battery lifetime.
Medical Metro
13
Product
Features:
Available from 20 to 4,000 kVA (8 x 500 kVA in parallel).
Parallel redundancy without requiring extra hardware to
Applications:
increase reliability.
Optional harmonic filter and 12-pulse rectifier.
Redundant auxiliary power and control circuit ensures
Data Center Telecom Industrial higher reliability.
Inbuilt maintenance and static bypass switch.
Multi-language LCD display and LED status indicators.
RS232, RS485 and six programmable dry contact outputs.
Network Security Lab Compatible with generator installation and unbalanced
loads.
Optional external battery cabinet for longer backup time.
Parallel expansion as your business grows and
consequently saves initial investment.
Medical Metro
Wide input voltage range extends battery lifetime.
Economy mode saves energy and operating cost.
Common battery installation saves initial investment.
14
Delta UPS Ultron Family
Features:
Applications: Double-conversion and IGBT-rectifier design.
N+X redundancy or hot-standby configuration.
Wide input voltage range reduces battery discharging
occurrence.
Data Center Telecom Industrial
Advanced battery management optimizes battery
performance and lifetime.
Field programmable sequential start-up 2 to 99 seconds
even without paralleling.
Network Security Lab Redundant fan design (optional).
System efficiency up to 96% saves operating cost.
High input power factor (> 0.99) and low input harmonic
distortion (iTHD < 3%) save upstream investment.
Medical Metro
Easy parallel expansion for future business growth.
Multi-language mimic LCD display and LED status
indicators.
AC-start and battery-start capabilities.
Inbuilt maintenance and static bypass switch.
Hot-swappable fans for easy replacement.
Optional model with built-in transformer.
15
Product
Applications: Features:
Available from 20 to 480 kVA (4 units x 120 kVA in parallel).
Redundancy at module and system level.
Hot-swappable function ensures uninterrupted operations
Data Center Telecom Industrial
during maintenance.
Redundant auxiliary power and control circuit ensures
higher reliability.
Inbuilt maintenance and static bypass switch.
Network Security Lab Modular design provides easy maintenance and scalability.
Multi-language LCD display and LED status indicators.
Two smart slots and six programmable dry contact outputs.
Optional external battery cabinet for longer backup time.
Medical Metro Low harmonic distortion (iTHD<3%) optimized generator
size to save initial investment.
High input and output power factor (I/P pf >0.99; O/P pf up
to 0.9) and 94% high efficiency reduce operating costs.
16
Product Application Matrix
Agilon Amplon
Configuration1:1 O O O O O
Configuration3:1
Configuration3:3
Rackmountable O
Standalone O O O O O
Isolationtransformer O
Backup S L S, L S, L L
Homeandoffice* O O O
Smallenterprise,ITand
O O O
medical**
Mediumenterprice,
telecom,IT,media***
Heavyindustry,telecom,
IT,Industrial****
17
Product
Ultron Modulon
O O O
O O O O
O O
O O O O O O
O O
L S, L L L L L
O O
O O O O O O
O O O O
18
UPS Management
SNMP card
Network
SNMP SNMPv1 protocol support; accepts NMS monitoring as
well as actively sends Trap packets to target hosts.
HTTP Monitor and set up through network browser with built-
in web server.
Others Telnet, TFTP, FTP, BOOTP, SMTP, SNTP and WOL.
MIB Supports RFC1628 and custom defined UPSv4 MIB.
Management
Regular power Can set up UPS power on and off time.
on and off
Regular testing Battery discharge test to ensure the battery is in good
condition.
Smart power off Can send power off signal to connected host actively
if the host computer has the InsightPower Client or
SNMP power off proxy installed.
Sensor Optional environment sensor can integrate ambient
temperature and humidity for total cabinet monitoring.
Diagnosis
Event log Keep date, time, and event sequence in event log file.
History records Keep date, time, and UPS parameter data. Can be
exported into XLS file for further processing.
Reaction to events
UPS shutdown Define delay time for UPS power off to avoid deep
discharge.
Email Send email notification to predefined recipients in case
of power event.
Technical specifications
10/100MRJ45connector
Operationtemperature 0 ~ 40C
Operationhumidity 10 ~ 80 %
Inputpower 9 ~ 24 VDC
Powerconsumption < 1W
Dimensions 130 x 60 mm
Weight 58 g
19
Product
Network
SNMP SNMPv1/v3 protocol support; accepts NMS monitoring
as well as actively sends Trap packets to target hosts.
HTTP/HTTPS Monitor and set up through network browser with built-
in web server.
Others Telnet, SSH, FTP, SFTP, BOOTP, DHCP, SMTP, SNTP
and RADIUS, Syslog.
MIB Supports RFC1628 and custom defined UPSv4 MIB.
Management
Regular power Can set up UPS power on and off time.
on and off
Regular testing Battery discharge test to ensure the battery is in good
condition.
Smart power off Can send power off signal to connected host actively
if the host computer has the InsightPower Client or
SNMP power off proxy installed.
Sensor Optional environment sensor can integrate ambient
temperature and humidity for total cabinet monitoring.
Diagnosis
Event log Keep date, time, and event sequence in event log file.
History records Keep date, time, and UPS parameter data. Can be
exported into XLS file for further processing.
Reaction to events
UPS shutdown Define delay time for UPS power off to avoid deep
discharge.
Email Send email notification to predefined recipients in case
of power event.
Technical specifications
10/100MRJ45connector
Operationtemperature 0 ~ 60 C
Operationhumidity 0~90% (Non- condensing)
Inputpower 12 Vdc
Powerconsumption < 2W
Dimensions 130 X 60 mm
Weight 75 g
20
UPS Management
EnviroProbe
LCD display
Ambient temperature and humidity monitoring
Four dry input signal connectors
Supports both RS232 or RS485 communications
Supports series connections for up to 10 EnviroProbes
Supports SNMP communications protocol
Network cable
HUB
Insight Power
UPS SNMP card EnviroProbe
Technical specifications
Model EMS1000
Input Connect to UPS SNMP card: 12Vdc (pin 1 & 4) with PDU
SNMP card: 5Vdc (pin 2 & 4)
Dimensions(WxDxH) 66 x 99 x 30 mm
Weight 120g
Temperature 1C @15 ~ 35C 2C @ 0 ~ 15C and 35 ~ 45C
Relativehumidity 20 ~ 90%
Humidityaccuracy 10% from 15 ~ 35C
Height 0 ~ 10,000 feet
Safetyregulationcompliance CE, EN55022 Class B, EN55024
21
Product
Output
Programmable 6 output relays, each of them can be
configured to represent one of the 20 UPS
events respectively
NC/NO 6 output relays, each of them can be
configured to either NC (Normal Close) or
Technical specifications NO (Normal Open)
Input
5port10/100MRJ45connector Programmable The input signal can be configured to
Operationtemperature 0 ~ 40C turn off the UPS or to issue battery test
Operationhumidity 10 ~ 80 % command
Inputpower 8 ~ 20 VDC
Powerconsumption < 1.2W
Dimensions 130 x 60 mm
Weight 200g
Modbus card
Convert status and parameter data of your UPS to comply with the
standard Modbus protocol
22
UPS Management
Mini-SNMP Card
Technical specifications
23
Product
Communication Protocol
SCI: Delta Regular v1.51
USB: Delta HID Protocol v3.4
Support HID (Human Interface Device) protocol
The UPS can communicate with Windows
2000/XP/Vista/2003 without monitoring software
Compatible with Delta UPS standard software: UPSentry Smart 2000
Technical specifications
Size 68 x 43 mm
Weight 30 g
OperatingTemperature 0 ~ 40 C
OperatingHumidity 10 ~ 80 %
PowerInput 12V DC
PowerConsumption 0.5 Watts
Technical specifications
Size 68 X 43 mm
Weight 35g
OperatingTemperature 0 ~ 40 C
OperatingHumidity 10 ~ 80 %
PowerInput 8 ~ 20V DC
PowerConsumption 0.8 Watts
24
UPS Management
Mini TVSS Card
Functions and features
This connection is optional but highly suggested as network lines often carry
dangerous surges and spikes
Connect the Network Protection Lines
Connect the network line from the wall to the connector marked IN, then
connect the device (Ethernet card) to be protected to the connector marked
OUT
Technicals pecifications
Size 46 x 43 mm
Weight 25g
OperatingTemperature 0 ~ 40 C
OperatingHumidity 10 ~ 80 %
Key functions
Centralized
ShutdownOS Remotecontrol
management
InsightPower Client
UPSentry Smart 2000
InsightPower Manager
Shutdown Agent
25
Product
UPS Management
Insight Power Manager
Functions and features
Operating systemsupport
Supports Microsoft Windows, 2000, XP, 2003, Vista, Win7, 2008
Diagrammatic sketch of operating system :
HUB
InsightPower Manager
InsightPower Manager
Database
Client
SNMP card
(For IT environment)
26
Display
Responsive actions
Event log
Network broadcasting
Voice alert
Email
SMS
Event tracking
Log UPS events and operation record in sequence of date and time
Supports historical data and curve display as well as exporting as files in
Excel format
Supports statistical report generation in a specified time range
27
Product
UPS Management
Insight Power Client
Keep power events in sequence of date, time, and Weekly or by given dates
event description Power on and off time setups
Voice alert Fast battery test
Network broadcasting Deep battery test
Email
SMS
Executes external programs and commands
On-the-spot digital monitoring Keeps power events in sequence of date, time, and
Multiple display format including: dashboard, scale, event description
indicator and graph Keeps digital records for power quality analysis
Fast event and historical
data inquiry
Automatic historical data
Smart power off
statistics
Press the smart power off button in web page of SNMP
card to turn off any operating system installed with
Insight Power Client and Shutdown Agent programs
Smart power off shares the same settings with battery
capacity low
28
UPSentry Smart 2000
Supports RS232 and USB communication Multi-language design (English, French, German,
Multi-language design (English, French, German, Spanish, Portuguese, Italian, Polish, Chinese and
Spanish, Portuguese, Italian, Polish, Chinese and Japanese)
Japanese) Support multi-hosts sleep/wakeup by cross platform
Support multi-hosts sleep/wakeup by cross platform software Master/Slave structure without SNMP card
software Master/Slave structure without SNMP card Human free automatic operating system close and
Human free automatic operating system close and archive
archive Slave Slave Slave
FreeBSD
Network cable
Sun Sparc and x86 Power cord
HP-UX RS232
Master UPS
IBM AIX
Scheduling
System power on/off
10 seconds test and deep discharge test
Socket group control
29
Product
UPS Management
Shutdown Agent
Shutdown
Agent
SNMP Trap SNMP
Network cable Trap
Power cord
30
Technical Specifications
VX Series, Single Phase
Model VX-600
PowerRating 600VA/360W
31
Technical Specifications
Technical Specifications
E Series, Single Phase
32
Technical Specifications
N Series, Single Phase
Interface Standard RS232 x 1, Smart slot x 1 RS232 x 1, SNMP slot x 1 RS232 x 1, SNMP slot x 1
Physical Dimensions (WxDxH) 140 x 366 x 242 mm 140 x 425 x 373 mm 140 x 425 x 373 mm
Weight 14 kg 30.5 kg 30.5 kg
33
Technical Specifications
Technical Specifications
R Series, Single Phase
Model R-1K R-2K R-3K
PowerRating 1kVA/700W 2kVA/1400W 3kVA/2100W
36
Technical Specifications
IN Series, Single Phase
1-3kVA
Model/Rating* 1kVA / 800W 2kVA / 1600W 3kVA / 2400W
* Rated output at 250 C ** Lower range 80 ~ 176 Vac is acceptable under 50 ~ 100% loading condition. Customise variants can be offered against
specific customer requirements. Product Developement is continuous process and all specifications are subject to change without prior notice.
34
Technical Specifications
Technical Specifications
RT Series, Single Phase
Model RT-5K RT-6K RT-10K
PowerRating 5kVA/4.5kW 6VA/5.4kW 10kVA/9kW
Physical Dimensions UPS 440 x 671 x 89 mm 440 x 671 x 89 mm 440 x 623 x 131 mm
(WxDxH) Battery Pack 440 x 638 x 89 mm 440 x 638 x 89 mm 440 x 595 x 131 mm
* For 5 and 6 kVA models, lower range 100 ~ 155 Vac is acceptable under 50 ~ 100% loading condition.
For 10 kVA model, lower range 100 ~ 180 Vac is acceptable under 50 ~ 100% loading condition.
** Audible Noise is at 70% load.
All specifications are subject to change without prior notice.
35
Technical Specifications
J Series, Single Phase Three Phase
Model
Input
37
Technical Specifications
Technical Specifications
H Series, Three Phase
Model H15K 3/1 H15K 3/3 H20K 3/1 H20K 3/3 H30K 3/3
PowerRating-kVA 15 15 20 20 30
PowerRating-kW 12 12 16 16 24
Output Voltage 3/3 model: 220/380, 230/400, 240/415 Vac (3 phase, 4-wire + G)
3/1 model: 220/230/240 Vac (single phase)
Voltage Harmonic Distortion 3% (linear load)
Voltage Regulation 2%
Frequency 50 or 60 0.1 Hz
Overload Capability 102 ~ 125%: 1 minutes; 125 ~ 150%: 30 seconds; > 150%: 2 seconds
Efficiency AC-AC 3/3 model: 90% (full load) 3/1 model: 90% (full load)
ECO Mode 3/3 model: 97% (full load) 3/1 model: 97% (full load)
38
Technical Specifications
NT Series, Three Phase
Model NT-20K 30K 40K 50K 60K 80K 100K 120K 160K 200K 260K 320K 400K 500K
PowerRating-kVA 20 30 40 50 60 80 100 120 160 200 260 320 400 500
Input Nominal Voltage 208/120, 380/220, 400/230, 415/240, 480/277 Vac (3 phase, 4-wire + G)
Voltage Range 20%
Current Harmonic Distortion < 3% (with optional rectifier or filter, full load)
Frequency 50 or 60 Hz 5Hz
Output Voltage 208/120, 380/220, 400/230, 415/240, 480/277 Vac (3 phase, 4-wire + G)
220, 230, 240 Vac (1 phase, 2-wire + G) *
Voltage Harmonic Distortion 3% (linear load)
Voltage Regulation 1% (static)
Frequency 50 or 60 Hz
Frequency Regulation 0.01% (interior oscillator); 1% (synchronized)
Overload Capability 110%: 60 minutes; 110 ~ 125%: 10 minutes; 126 ~ 150%: 1 minute
Interface Standard RS232 x 1, RS485 x 2, SNMP slot x 1, Status dry contact output x 6
Weight *** kg 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410
* Single phase output voltage: 220/230/240 is only for 20 ~ 120 kVA models.
** Standard rating is 380/220 Vac with 6 pulse rectifier. For models: (1) different rating (2) with 12 pulse rectifier or filter, dimensions and weight would be
different
from standard models. Please contact your local supplier for more information.
*** 500 kVA model is assembled into two cabinets: Inverter (width=1100 mm, 1760 kg) and Rectifier (width=800 mm, 650 kg).
All specifications are subject to change without prior notice.
39
Technical Specifications Technical Specifications
Technical Specifications
DPS Series, Three Phase
Model DPS-160K DPS-200K
PowerRating-kVA 160 200
Interface Standard RS232 x 1, SNMP slot x 2, Dry contact output x 6, Dry contact input x 2,
Battery cabinet temperature x 4, Battery cabinet status detection x 1,
Parallel port x 2, REPO x 1
Management Peripherals SNMP card, Modbus card, Relay I/O control card, EnviroProbe, SNMP hub,
* When input voltage is 242 ~ 324/140 ~ 187 Vac, the sustainable loading is from 70% to 100% of the UPS capacity.
All specifications are subject to change without prior notice.
40
Technical Specifications
NH Plus Series, Three Phase
Model NHP-20K NHP-40K NHP-60K NHP-80K NHP-100K NHP-120K
PowerRating-kVA 20 40 60 80 100 120
PowerRating-kW* < 25C* 18 36 54 72 90 108
< 40C 16 32 48 64 80 96
Input Nominal Voltage 380/220, 400/230, 415/240 Vac (3 phase, 4-wire + G)
Voltage Range 208 ~ 477 Vac (line-line)/120 ~ 276 Vac (line-neutral) **
Current Harmonic Distortion < 3% (full load)
Power Factor > 0.99
Frequency 50 or 60 5 Hz
Output Voltage 380/220, 400/230, 415/240 Vac (3 phase, 4-wire + G)
Voltage Harmonic Distortion < 3% (linear load)
Voltage Regulation 1% (static)
Frequency 50 or 60 Hz
Frequency Regulation 0.05 Hz (interior oscillator)
5 Hz (synchronized, adjustable in steps of 0.1 Hz)
Overload Capability 125%: 10 minutes; 150%: 1 minute
Interface Standard RS232 x 1, SNMP slot x 2, Dry contact output x 6, Dry contact input x 2,
Battery cabinet temperature x 4, Battery cabinet status detection x 1, Parallel port x
1, REPO x 1
Management Peripherals SNMP card, Modbus card, Relay I/O control card, EnviroProbe,
SNMP + 5 ports hub, Battery cabinet temperature sensor, Battery cabinet status
cable
Conformance Safety & EMC CE, EN62040-1, EN62040-2 Class A
OtherFeatures Parallel Redundancy and Module and system redundancy; Maximum 4 units in parallel up to 480 kVA
Expansion
Emergency Power Off Local and remote
SRAM Event Log 500 records
Efficiency AC-AC 94%
ECO Mode 97%
Environment Operating Temperature 0 ~ 40C
Relative Humidity 0 ~ 90% (non-condensing)
Audible Noise (at one meter) 65 dBA 68 dBA 68 dBA 70 dBA 72 dBA 73 dBA
Physical Dimensions UPS 520 x 910 x 1165 mm 520 x 975 x 1695 mm
(WxDxH) Battery Pack 520 x 850 x 1165 mm (26 Ah x 40 pcs) 520 x 975 x 1695 mm
(40 Ah x 40 pcs)
Weight 170 kg 200 kg 230 kg 260 kg 350 kg 380 kg
41
UPS Q& A
UPS Q&A
Power issues
Q What are the power issues?
Based on a survey made by Contingency Planning, poor power quality is the key factor in computer data loss. In
A addition to black outs, other power quality problems are: voltage sag, spikes, voltage surges, noise, and voltage too
low (high). These are the events that lead to damage and reduce the life of computer components as well as cause
data loss and damage.
There are quite a few methods for dealing with power problems. The three most commonly used are: a surge
A absorber, a regulator or a UPS.
Solution
Powerissue
Surge absorber Regulator UPS
Black out X X
Sag
Surge
Noise X X
Spike
Frequency drift X
Voltage sag is the most common power problem we may encounter and it is responsible for 87% of all power issues.
A A voltage sag is a short period of voltage drop caused by some outside problem. This may result in operation failure
of computer peripherals, such as the keyboard in minor cases, or it might lead to data loss and file damage in its more
serious form. Voltage sag may also damage computer components and reduce their working lives.
A spike is a great increase in voltage of very short duration. In most cases it is generated by lightning in nearby
A regions. It may damage computer hardware or precision equipment and result in data loss.
When powering off high-current equipment or a group of high load equipment connected to a single power source, an
A inertial voltage surge may be generated during power transmission. Most computers or precision equipment feature a
certain range of operational voltage that accommodates such a situation. However, if the voltage surge is greater than
the tolerance settings, some equipment or components may be damaged and this can lead to equipment failure and a
reduced working life.
A score of factors are responsible for noise, including lightning, the powering on or off of nearby equipment,
A generators, and even wireless communications. Noise may cause precision equipment or computers to fail or result in
program runtime errors.
42
UPS Q&A
Types of UPS
Q Why is a UPS needed?
Unsteady power quality can affect the normal operation of a computer. A UPS not only provides immediate power in
A case of blackout, but also provides stable and clean power under normal conditions. It improves the incoming power
by regulation and filtration and also suppresses spikes caused by lightning. A UPS, is like a personal insurance policy
and protects your computer equipment against power risks.
Q What kinds of UPS are there?
Suppressor
DC-AC converter
+ -
Battery Inverter
Grid power supply path
43
UPS Q& A
UPS Q&A
Common battery problems
Most commercially available UPS use sealed lead-acid batteries that are water-and maintenance-free. The energy is
A generated by chemical reactions in a paste-like electrolyte. For most consumers, these batteries are not only easy to
use and maintain but also simple to replace when necessary.
The power provided by a UPS comes from the discharge of its batteries. Batteries age not only with use and external
A factors but also from the internal chemical reactions. Batteries will still age even when not in use. Generally speaking,
the average life of a lead-acid battery is 2 years.
Regular charging and discharging is very important for battery maintenance. You can regularly execute this function if
A your UPS has the battery detection feature. Otherwise, you can simply unplug the input to your UPS to simulate a grid
power black-out and check the time the battery takes to discharge. Please replace your batteries with new ones when
the discharge time becomes less than that given in the specification. This will ensure that there is enough discharge
time for the system to save files and be shut down in case of grid power failure.
Most commercially available UPS now express their capacity as VA. V stands for voltage and A for current in amps. In
A short, VA equals the power and capacity of a UPS. For example, a UPS of 500VA capacity with an output of 110V will
provide a maximum current of 4.55A and more than this will lead to overload. The unit of power can be expressed in
Watts. While the Watt indicates active power, VA indicates reactive power and Watt equals VA multiplied by the power
factor (VA pf = Watt). There is no common criterion for power factor (pf). Generally a value of between 0.6 and 0.8 is
acceptable while a value of 0.5 may represent poor design. Pay attention to this value when purchasing a UPS. A high
power factor implies better utilization and more economical use of power.
Please contact the service center or your UPS dealer when you need to replace your batteries.
A
Q Where can an appropriate UPS be bought?
1. Learn about the applicability of each type of UPS. 2. Appraise your needs for power quality.
A 3. Learn the required UPS capacity and appraise the total capacity required for future expansion.
4. Select a market proven brand and supplier.
5. Purchase an appropriate UPS that is suitable for your requirements.
Statistics indicate that black-outs are a minor power issue. Other, not so obvious power issues, like over-voltage,
A under-voltage and surges are the major ones. In addition to providing extended power for long stretches, a UPS
is designed to provide customers with critical total power protection against voltage drift, surges, high frequency
interference, and any other kind of power failure and drift.
The single most important function of a UPS is to provide adequate backup power for the equipment load. The time
A a UPS should provide power should be long enough for users to finish running reaction procedures in case of power
failure. In general, 5 to 10 minutes should be enough. If longer than this is required, you can purchase a UPS that
includes an external battery cabinet(s) that will increase the UPS backup time.
44
DeltaPowerSolutions(India)Pvt.Ltd
Client List: Delta UPS from 600VA to 4000kVA is installed at various locations all across India in
major organizations and serve diversified industries:
Automobile Industry: Amtek Auto Limited, Federal Mogul Goetze Infia Ltd, International tractors,
OverseasBusinessCorporation, Sona Koyo Steering SystemsLimited, SPM Autocomp System Pvt. Ltd,
Spray Technics, Mitsubishi Electric Automotive India Pvt. Ltd, etc.
Animation Industry and Media: HTMedia Ltd, Department Of Post India, Basking Lions Animation Pvt
Ltd, DQ Entertainment International Pvt. Ltd, Reliance Media Works Ltd etc.
BFSI:Bank of Baroda, Banking ATM Infrasolutions Ltd, ICICI Bank, Rentworks India Pvt Ltd, Stock
Holding Corporation, Tata Communications Banking etc. Reserve Bank Of India, National Insurance Co. Ltd
ConstructionIndustry: Ambuja Cement Ltd, Gujarat Ambuja Cement, IVRCL Infrastructure and
Projects Ltd, Paharpur Cooling Towers Ltd, Navayuga Engineering Company Ltd, Gurind GlassPvt Ltd,
Anant Raj Industries Ltd, SVSPropmart Pvt Ltd etc.
Education:Indian Institute Of Technology, Central Institute of Post Harvest Engineering & Technology,
Central Salt & Marine Chemicals Research Institute, CF Health Solutions Pvt Ltd, CHA Engineering &
Construction Pvt Ltd, CMR Institute of Technology, CMR Jnanadhara Trust, CMR National Public
School, Govt. Medical College, Indian Agriculture Static ResearchInstitute, Indian Institute of Science,
IndoAmerican Cancer Institute & Research Center, Institute Of Himalayan Bioresourse Technology,
Kendriya Vidyalaya Sangathan,Proudhadevaroya Institute of Technology, Rotary publics School etc.
Government: Airport Authority of India, National Insurance Company Limited, Border Security Force,
Central Reserve Police Force, Headquarters Eastern Command, Indian Navy Services, Jammu &
Kashmir Light Infantry Regimental Centre, Integral CoachFactory, Indian Coast Guard etc.
45
Hospital& Health Care:Apollo Hospital Enterprises Ltd, Dr Lal Path LabsPvt Ltd, Lifecare Hospital, NU
Hospitals, Shree Moolchand Khairati Ram Hospital, MYLAN,Vijaya Diagnostic Center Pvt Ltd etc.
IT/ ITes: Aargee Equipments Pvt Ltd, Bartronics India Pvt Ltd, CMS Computers Ltd, Department Of
Information Technology, DIACServices,Electro SalesCorporation, HP India SalesPvt Ltd, HCLComnet
Ltd, IBM Daksh Business ProcessServicesPvt Ltd, Immence Technologies Ltd, Millenium Automation
& System Ltd, Online IT Solutions Pvt Ltd, PCSTechnology Ltd, Powerview Technologies, Prime Ki
Software Solutions Pvt Ltd, SDSPower Technologies Pvt Ltd, Spanco Ltd, Byond Global Outsourcing
Pvt Ltd, Tacket Technologies Ltd, Telserra India Pvt Ltd, Wipro India Ltd, Wise Men Consulting Service
India Pvt Ltd etc. Amazon Development centre (India) Pvt Ltd. Amazon Seller services Pvt Ltd., NEC
Oil and EnergyIndustry: APS Technologies, Gas Authority of India Ltd, Oil and Natural Gas
Corporation, India Petrochemicals Pvt Ltd, Reliance Industry Ltd, Samsung Engineering India Pvt Ltd,
Windlass Engineers & ServicesPvt. Ltd etc.
Pharmaceuticals Industry: AptuitLaurus Pvt Ltd, Ashco Niulab Industries Ltd, Coronet LabsPvt Ltd, Dr
Reddy Laboratories Ltd, Labindia Instruments Pvt Ltd, Ogene Systems India Pvt Ltd, Sutures India Pvt
Ltd, Suven Nishtaa Pharma Pvt Ltd, Mylan Laboratories Limited, Matrix Laboratories Limited, Gvk Bio
SciencesPvt. Ltd, Bigtec Private Limited, Bharat Biotech International etc.
Plastic &Polymer Industry : Arihant Poly PacksLtd, Everest Polymers Pvt Ltd, Everest Vinyl Pvt Ltd,
Kunnathan Polymers Pvt Ltd, Saffire International, Veekay Polycoats Ltd etc.
Suppliers & Manufacturers: Amco India Ltd, Sterlite Technologies Ltd, Auric Communication Pvt Ltd,
Balkrishna Industries Ltd, Bhole Baba Diary Industries Ltd, BMW Industries Ltd, BPE India Pvt Ltd,
Gujarat Cablesand Enamelled Products Pvt Ltd, Halgona Radiators Pvt Ltd, New Holland Tractors India
Pvt Ltd, Paliwal Exports, Pulraj Electronics Pvt Ltd, Siemens Public Communications Network Pvt Ltd,
SaraSaePvt. Ltd etc.
Textiles: VTex OverseasPvt Ltd, Kurshang Apparels Pvt Ltd, Weavetex Overseas,Xinda Non wovens,
Wool Worths Wholesales India Pvt Ltd, Guru Kirpa Tex Fab, Aditya Nonwoven FabricsPvt. Ltd etc.
Telecom Industry: Vodafone India Pvt Ltd, Samsung Telecommunications India Pvt Ltd, Tata
Teleservices, Aditya Birla Telecom Ltd, Aircel Cellular Ltd, Aircel Ltd, Alcatel Development India Pvt
Ltd, Alcatel Lucent India Ltd, Bharat Sanchar Nigam Ltd (BSNL),Bharti Airtel Ltd, Bharati Cellular Ltd,
Bharti Hexacom Ltd, Bharti Infratel Ltd, Bharti Tele Ventures Ltd, BPL Mobile Cellular Ltd, Commtel
Networks Pvt Ltd, Ericsson India Pvt Ltd, Huawei Telecommunications India Co Pvt Ltd, Idea Cellular
Ltd, India Mobility ReseachPvt Ltd, Indus Towers Ltd, Mars Associates Pvt Ltd, Microqual Techno Pvt
Ltd, Motorola India Pvt Ltd, Nokia Siemens Networks Pvt Ltd, Ortel Communication Ltd, Radius
SynergiesPvt Ltd, Railtel Corportation Of India Ltd, Reliance Corporation of India Pvt Ltd, RN Infratech,
Sistema ShyamTeleservices Ltd, ShyamTelecom, ZTETelecom India Pvt Ltd, Viom Networks Ltd etc.
46
Plot No. 43, Sector - 35 Reliable tech park,Office 701, Ozone Manay Tech Park, A Block,
Gurgaon -122001, Haryana 7th floor off Thane Belapur Road,Airoli, 3rd Floor, Survey No, 56/18 & 55/9, Hosur Road,
TEL : +91 124 4874900 Navi Mumbai-400 708, MAHARASHTRA, INDIA Hongasandra Village, Bangalore 560068
FAX : +91 124 4874945 Ph: +91 22 61845200 Fax: +91 22 618453333 Ph: +91 80 6716 4777 Fax: +91 80 67164784
Kolkata
Plot No:68, Nagarjuna Hills, 4th Floor, Room#406, Matrix Tower,
Road No:1, Banjara Hills Plot#24, Block DN, Sector 5,
Hyderabad 500082 Salt Lake City, Kolkata - 700091
PH : +91 40 67274510 Tel: 91 33 65217306/07 Fax: 91 33 40063108
FAX : +91 40 67274545
Coimbatore
Pune Door No 123, 1st Floor
10 Ground Floor, Laxmi Ramaswamy Gounder Street, Saibaba Colony,
Plaza at Kasharwadu. Opposite Coimbatore- 641011
Alfa Laval Company, Mumbai-Pune
Tel: 0422-4202302
Road, Pune Tel: +91-9890576713
www.deltapowersolutions.com