(William H. Avery, Chih Wu) Renewable Energy From
(William H. Avery, Chih Wu) Renewable Energy From
(William H. Avery, Chih Wu) Renewable Energy From
William H. Avery
Chih Wu
SERIES EDITOR
JOHN R. APEL
BRUCE I. BLUM.
Software Engineering: A Holistic View
ROBERT M. FRISTROM.
Flame Structure and Processes
William H. Avery
DIRECTOR (RETIRED)
Ocean Energy Programs
The Johns Hopkins University
Applied Physics Laboratory
and
Chih Wu
PROFESSOR
Department of Mechanical Engineering
United States Naval Academy
987654321
Printed in the United States of America
on acid-free paper
To the Pioneers
This page intentionally left blank
Foreword
All too often when societies face crises involving population, energy, resources, or
environment they procrastinate until the problem can no longer be ignored. This
phase is followed by a period in which the society turns to panaceas or palliatives.
These cosmetic solutions mask and defer the problem until a new crisis erupts in a
new mode with heightened potential for catastrophe. Happily, some real solutions
to past problems have emerged. These solutions resulted from the work of problem
solvers who recognized that there were no short-term answers.
The energy-environmental crisis with which the world is wrestling, and has
wrestled for more than 2 decades, when coupled with the population explosion, will
be the most chronic and crucial of these world crises. We are now aware that the
panaceas of direct solar conversion, nuclear energy, and natural gas, even with the
palliatives of energy conservation, are ineffective solutions to the onset of global
warming. World competition surrounds the depleting pools of oil like a crowd of
thirsting dinosaurs.
Once again the establishment machinery is in motion to pump new life into
short-term solutions. But the readers of this book will recognize that long-term
solutions are an absolute necessity. One such solution is the development of ocean
thermal energy and the transportable nonpolluting fuels that can be obtained from
this large renewable reservoir.
Dr. William Avery and his colleagues were among the few teams who, in 1973,
asked themselves the scientific questionhow best to meet the energy crisis
without any preconceived notion or prejudice about what the solution might be.
Their long experience in the development of advanced technology made them
familiar with the scientific approach to innovation that strips away the conventional
wisdom of the past and reduces the problem to one of fundamental physics and
geophysics. This approach led to the identification of ocean thermal energy
conversion as a plentiful and practical way of alleviating world energy needs by
utilizing solar energy stored in the vast tropical oceans that is available night and
day, throughout the year.
Once identified, there was the analytical and experimental documentation of
practical ways of transferring this thermal energy into electrical energy and from
electrical energy to chemical energy in the form of hydrogen, ammonia, or
methanol. Each step required consideration of economics and environment as well
as technology with recognition that solutions must be economically viable and
environmentally sustainable.
viii
As early as 1975 A very and his colleagues had identified the sea-based
manufacture of ammonia as an economically and environmentally feasible energy
option, but the implementation of this option was held back by the availability of
"low-cost fuel." The economic and environmental impacts of dependence on
Middle East fuel supplies were disregarded. As a consequence the team was
reduced in size and then all but abandoned. Avery and Wu have pooled the
knowledge gained and in this book have carefully and meticulously documented the
studies and experimental results of the small band of investigators who persisted in
the exploration of this vital resource.
Who would deny that we are once again in the middle of an energy/
environmental/population crisis? Now, however, a critical mass of investigators
employing the waters of Hawaii as their laboratory have developed the proof that
ocean thermal energy and its by-products are an important element in a rational and
environmentally sustainable solution. This important work is being recognized.
Relevant pilot projects now exist in Britain and Hawaii, and developments are
under serious consideration in the Cook Islands, the Marshall Islands, and the Cape
Verde Islands. The entrepreneurs who have independently entered the development
process will soon be joined by others. This book will be their bible.
John P. Craven
Former Dean of Marine Engineering
University of Hawaii
Preface
The upper layers of the tropical oceans are a vast reservoir of warm water that is held
at a temperature near 27C (80F) by a balance between the absorption of heat from
the sun and the loss of heat by evaporation, convection, and long-wavelength
radiation. On an average day, the water near the surface absorbs more heat from the
sun in one square mile of ocean area than could be produced by burning 7000 barrels
of oil. For the whole tropical ocean area, the solar energy absorbed per day by the
surface waters is more than 10,000 times the heat content of the daily oil
consumption of the United States. A practical and economical technology for
converting even 0.01 % of the absorbed solar energy into electricity or fuel in a form
suitable for delivery to consumers on land could have a profound impact on world
energy availability and economics.
The technology called ocean thermal energy conversion (OTEC) fulfills the
technical and economic requirements for productive use of the solar energy
continually absorbed by the oceans. However, the unfamiliarity of the OTEC
concept and misconceptions about the difficulty of implementing it have slowed the
development of interest by industry and government.
This book presents the scientific and engineering fundamentals of OTEC
technology in a context that will make clear how this technology can be applied in
a practical way to a future world economy based on renewable, nonpolluting energy
sources. The status of OTEC development programs is presented, and technical and
cost information are provided from which valid estimates can be made of OTEC
plant investment requirements and delivered costs of OTEC fuels, chemicals, and
electric power. The book shows that the technology base for OTEC is sufficiently
well established for large-scale demonstration plants to be built as forerunners to
commercial plants and plantships that will be economically attractive and environ-
mentally benign. The manufacture of OTEC plants and plantships can draw on the
talents and facilities available in the U.S. chemical and power production industries
and in shipyards, steel companies, and concrete construction firms. OTEC commer-
cialization offers many new employment opportunities, including large require-
ments for low-skilled laborers.
OTEC-produced fuels can be an inexhaustible substitute for petroleum-based
fuels and could ultimately be produced in quantities and at costs that would make
it practical for this technology to supply a large part of the energy needs of the world.
After an introductory overview, the book reviews the history of OTEC
development and presents a discussion of the scientific and engineering fundamen-
tals of the technology, including the technical options for electrical and chemical
energy delivery. The engineering status, projected costs (which are favorable in
X
Acknowledgments
A few farseeing and dedicated individuals created programs in the early 1970s that
expanded rapidly to establish OTEC technology as a renewable energy resource
with the potential to make major contributions to world requirements for safe,
benign, and inexhaustible energy sources. The senior author (WHA) has been
privileged to know and have the support of the early American investigators, and
to play a part in the efforts of the large teams of scientists and engineers who worked
to bring OTEC into operation in the early 1980s. Unfortunately only a small number
of those whose contributions were vital to the success of the technical program can
be given credit for their contributions. Since team efforts were the rule, it is
appropriate to recognize individuals in conjunction with the organizations that
supported their work. To all of them we are grateful.
J. Hilbert Anderson, Sea Solar Power, Inc.: His innovative engineering
concepts and tireless enthusiasm brought OTEC to the attention of the engineering
community and inspired future efforts worldwide.
Clarence Zener, Carnegie-Mellon University: His physical insight into en-
ergy options led to his interest in OTEC, and his international prestige created
significant support for OTEC within the National Science Foundation, ERDA, and,
finally, DOE.
Robert Cohen, NSF, ERDA, and DOE: He was able to maintain funding for
OTEC despite unenthusiastic support from the federal bureaucracy and the energy
establishment.
Marvin Pitkin, MARAD: His recognition of the commercial promise of OTEC
brought funding from the U.S. Maritime Administration (MARAD) for vital
studies of the shipbuilding and commercialization requirements.
Eugene Schorsch: His interest in OTEC gained the support of the management
of the Sun Shipbuilding and Drydock Company, who, at their expense, assigned a
team to work with JHU/APL to define the marine engineering requirements and
conceptual design of a concrete barge that would minimize OTEC shipbuilding
costs.
John Craven, University of Hawaii: His deep understanding of ocean science
and engineering combined with political prowess induced the government of
Hawaii to recognize the unique capabilities of Hawaii to become a world center for
renewable energy development, with particular emphasis on OTEC. This led to the
establishment of the Natural Energy Laboratory in Hawaii.
The Lockheed team: Under the leadership of James Wentzel and Lloyd
Trimble, Lockheed, with support from the State of Hawaii and industrial partners,
built and operated the Mini-OTEC vessel with private funding, demonstrating for
the first time net power production from solar thermal energy stored in the oceans.
xi
The TRW team: Under the leadership of Arthur Butler and Robert Douglass,
the TRW team conducted the program that developed and performed the at-sea
demonstration of the OTEC-1 heat exchanger test vehicle.
ABAM Engineers: Robert Mast and his associates generously provided
engineering and cost data acquired in the design and construction of the concrete
ARCO LPG vessel, information that was vital to the design of the 40-MWe OTEC
baseline demonstration vessels.
SOLARAMCO: J. F. Babbitt graciously furnished detailed information for
the design of an ammonia plant suitable for installation on an OTEC plantship,
based on his wide background in ammonia plant construction and operation.
Brown and Root Development, Inc. (BARDI), EBASCO Engineering, and
Rocketdyne International Corp.: Teams from these organizations, led by J. D.
Shoemaker, W. G. Niemeyer, and Farouk Mian of BARDI, Malcolm Jones of
EBASCO, and Arthur Kohl of Rocketdyne, cooperated in the conceptual design of
the 200-MWe OTEC methanol plantship, generously making available much of
their relevant in-house development and construction experience.
The DOE Ocean Energy team: William Richards, William Sherwood, Car-
mine Castellano, and Peter Ritzcoven of DOE, and Abraham Lavi, on leave from
Carnegie-Mellon University, recognized the potential of OTEC to make large
contributions to world energy needs and were able temporarily to manage a
program in DOE that provided solutions to the perceived technological problems.
As a consequence, OTEC is ready to proceed to large-scale demonstration when
financing becomes available.
The pioneering work of the French and Japanese teams is reviewed in
Chapter 3.
We are deeply indebted to our associates at JHU/APL and the Naval Academy
whose engineering understanding and program management capabilities provided
insights essential to the success of the program and the writing of this book.
Particular credit is due to Gordon Dugger (deceased), Dennis Richards, E. J.
Francis, R. W. Blevins, James George, W. B. Shippen, and Peter Pandolfini of JHU/
APL. We are also deeply grateful to Michael McCormick of the U.S. Naval
Academy for his support and counsel.
The vital help of those concerned with the production of the book is acknowl-
edged with deep gratitude: Jeffrey Robbins and Anita Lekhwani of the Oxford
University Press; JHU/APL management under the direction of Carl Bostrom; John
Apel, Laurie Fetcher, Carol West, Terry Gordon, Murrie W. Burgan, and Ruth
Novick of JHU/APL; P. R. Wells and C. A. Mayr of the United States Naval
Academy; and G. A. Bare of the United States Air Force.
Finally, both authors are deeply aware that nothing of value would have been
accomplished without the enthusiastic, devoted, untiring, and patient support of
their wives, for whom no words of gratitude can be sufficient.
Chapter 5 and Sections 9.2 and 9.3 of Chapter 9 were written by C. Wu. The
remaining text was written by W. H. Avery.
This page intentionally left blank
Of a / / . . . inorganic substances . . . water is the most wonderful... if we
think of it as the source of all the changefulness and beauty which we have seen in
clouds; then as the instrument by which the earth we have contemplated was
modelled into symmetry, and its crags chiselled into grace; then as, in the form of
snow, it robes the mountains it has made, with that transcendent light which we
could not have conceived if we had not seen; then as it exists in the form of the
torrent. . . in the iris which spans it, in the morning mist which rises from it in the
deep crystalline pools which mirror its hanging shore, in the broad lake and
glancing river; finally, in that which is to all human minds the best emblem of
unwearied, unconquerable power, the wild, various, fantastic, tameless unity of the
sea; what shall we compare to this mighty, this universal element, for glory and for
beauty ? or how shall we follow its eternal changefulness of feeling ? It is like trying
to paint a soul.
John Ruskin
Foreword vii
Preface ix
INDEX 441
FIGURES
4-43 Pressure loss (hydraulic head) versus water flow velocity for Saga
University plate evaporator 140
4-44 Pressure loss (hydraulic head) versus water flow velocity for Saga
University plate condenser 141
4-45 Diagram of test module for JHU/APL folded-tube heat exchanger .... 142
4-46 Heat transfer versus flow rates of water and ammonia in ANL tests
of the JHU/APL folded-tube evaporator 143
4-47 Heat transfer versus water flow velocity in ANL tests of the
JHU/APL folded-tube condenser 144
4-48 Heat transfer in two-phase flow of ammonia in tests of the
JHU/APL folded-tube condenser 145
4-49 Design of Rocketdyne axial-fluted heat exchanger tube 146
4-50 Alternative concepts for cold-water pipe construction 157
4-51 Comparison of CWP dynamics measured in at-sea test, with
analytical predictions of Paulling computer programs 162
4-52 OTEC system characteristic frequencies in at-sea operation 164
4-53 Observed strains in at-sea test of FRP CWP 165
4-54 Typical off-shore profile for island-based OTEC plant 166
4-55 Deployment method for proposed FRP CWP at Tahiti 168
4-56 Voltage profiles for improved Electrolyzer, Inc., electrolysis
cells 171
4-57 Layout of 35-MWe Electrolyzer, Inc., hydrogen plant 172
4-58 Typical performance of GE SPE electrolyzer 173
4-59 Layout of 4-MWe module of GE SPE electrolyzer system 174
4-60 Performance improvements through research and development
of Teledyne Energy Systems electrolyzer 175
4-61 Schematic of Claude hydrogen liquefaction process 176
4-62 Cable construction for underwater power transmission 181
4-63 Proposed deployment arrangement for OTEC power cables 181
4-64 Dependence of drag coefficients on design for alternative OTEC
configurations 186
4-65 Drag force versus displacement for OTEC system alternatives 187
4-66 Power requirements for position control 187
4-67 Thruster types available for OTEC position control 188
4-68 Estimated cost of thrusters for OTEC position control 189
4-69 Estimated cost of OTEC position control using thrusters 190
4-70 OTEC position control combining mooring and thrusters 190
4-71 Alternative mooring arrangements for OTEC systems 191
4-72 OTEC-1 CWP support assembly 194
4-73 Types of flexible joints studied for OTEC CWP support 195
4-74 Diagram of universal joint for OTEC FRP cold-water pipe 196
4-75 Ball-and-socket design for 4-MWe OTEC CWP support 197
4-76 Alternative design of ball-and-socket support for 40-MWe
OTEC CWP 198
4-77 Layouts of OTEC ammonia plantships of various power outputs 200
XX
A map prepared by Wolff for the U.S. Department of Energy showing the
temperature difference in the tropical oceans between the surface and a depth of
1000 m (3287 ft) is presented in Fig. 1-1. The regions most suitable for OTEC
operation, in which the change in temperature (AT) exceeds 22 degrees Celsius (40
degrees Fahrenheit), have a total area of approximately 60 million km2 (23 million
miles2). Thus, if floating OTEC power plants were uniformly spaced throughout the
FIG. 1-1. Ocean temperature resource for OTEC (U.S. Department of Energy, Assistant Secretary
Energy Technology, Division of Solar Technology).
INTRODUCTION AND OVERVIEW 3
useful tropical ocean area, the total power generated on board would exceed 10
million MWe; if each plant generated 200 MWe of net power, the plants would be
spaced 32 km (20 miles) apart. For comparison, the total U.S. electricity-generating
capacity in 1987 was 165 thousand MWe.
Where deep water exists near the shore, for example, at tropical islands and
coral atolls and at some continental sites, OTEC plants may be on shore or shelf
mounted.
The following sections in this chapter present brief discussions of the general
design features of the major OTEC subsystems to show the basic relationships
among engineering and thermodynamic requirements, component design, and
system construction and performance that are necessary for a preliminary assess-
ment of OTEC technical feasibility and cost. Specific engineering information on
the design and construction of systems and components, and detailed cost and
performance estimates are presented in succeeding chapters.
Fig. 1 -4. In early 1981, an ocean-based OTEC power system (OTEC-1), including
a 670-m (2200-ft) CWP of 2.55 m diameter (8.4 ft), and cold- and warm-water
ducting equipment, was deployed and operated at 1 -MWe scale, also in Hawaii
(Castellano, 1981). A photograph of the ship and a layout diagram are shown in Fig.
1-5. These successful tests demonstrate that closed-cycle OTEC is ready for the
next major step: scale-up to a size large enough to provide detailed engineering data
on performance and cost for the design of commercial OTEC systems.
Open-cycle OTEC systems are still in the research and development phase but
offer promise of competitive performance, particularly if fresh water, and/or
mariculture products, produced along with or instead of electric power, are
marketable products at the plant site.
Since the purpose of this overview chapter is to give the reader an understand-
ing of the general features of OTEC design and operation, along with cost
information that will allow evaluation of the appropriate role of OTEC in future
U.S. and world energy development, discussion of open-cycle OTEC is postponed
until Chapter 5.
FIG. 1-4. Mini-OTEC deployed near Kailua-Kona, Hawaii (Courtesy Lockheed Missile and Space
Co.).
6 OCEAN THERMAL ENERGY CONVERSION
FIG. 1-5. (a) OTEC-1 heat exchanger test vessel deployed near Kalua-Kona, Hawaii (Courtesy C.
Castellano). (b) Layout diagram for OTEC-1 subsystems (Castellano, 1981).
FIG. 1-6. Flow diagram of typical OTEC heat engine power cycle.
INTRODUCTION AND OVERVIEW 7
enters a condenser cooled by water at 4.0C (39.2F), which is drawn from a depth
of approximately 1000 m (3300 ft).
The vapor pressure of ammonia at the temperature in the condenser, 10.3C
(50.6F), is 620 kPa (6.1 atm). Thus, a significant pressure difference is available
to drive the turbine and generate electric power.
As the ammonia condenses, the liquid is pumped back into the evaporator to
complete the cycle, producing continuous power generation as long as the warm
water and cold water continue to flow.
The closed OTEC cycle is basically the same as the conventional Rankine
cycle employed in steam engines, in which the steam is condensed and returned to
the boiler after driving a piston or steam turbine. OTEC differs by using a different
working fluid and lower pressures and temperatures.
The closed OTEC cycle is also essentially the same as that used in commercial
refrigerators, except that the OTEC cycle is run in the opposite direction so that a
hot source and a cold heat sink are used to produce electric power, rather than the
reverse. In refrigeration systems the temperatures and pressures of the working
fluid are almost the same as those of the OTEC cycle, and the same working fluid
may be used. Any of the common refrigerant fluids (freons) would be suitable for
OTEC operation, but ammonia is the preeminent choice. Thus, much of the large
body of technical information, engineering data, subsystems, and components
developed over the years for the manufacture of refrigeration and cryogenic
systems is directly applicable to OTEC and provides a good basis for the prediction
of OTEC performance and costs.
difference in vapor pressure in the ammonia between the evaporator and condenser,
and (2) the Ts required to induce a high heat transfer rate from warm water to
ammonia in the evaporator and from ammonia to cold water in the condenser. An
analysis is presented in Wu (1987).
Only the AT associated with the pressure difference across the turbine is
associated with the production of mechanical work; therefore, in practical operation
of an OTEC power system, the gross power efficiency is only about half the Carnot
limit. This requirement reduces the maximum practical efficiency of OTEC gross
power production to 3.5 to 4.0%.
Finally, analysis shows that 25 to 30% of the gross electric power generated
by a floating OTEC plant operating with a AT of 22 degrees Celsius (40 degrees
Fahrenheit) will be required to operate the water and ammonia pumps and to supply
power to meet auxiliary needs for plant operation and ship station keeping. Thus,
the net efficiency of conversion of the thermal energy stored in the ocean surface
waters to net electric energy available at the on-board bus bar will be between 2.5
and 3%.
The small value of the OTEC net efficiency compared with efficiencies typical
of heat engines that operate at high temperatures and pressures has led to assump-
tions by some energy planners that OTEC power would be too costly to compete
with other methods of power production; however, design studies supported by
research and development testing show that commercial production of OTEC will
be cost effective, for the following reasons:
1. OTEC involves no costs for fuel or for its preparation and storage.
2. The low pressures and temperatures of the OTEC cycle permit major reduc-
tions in component costs compared with conventional power systems, which
are dependent on high temperature, high pressure, and special materials for
efficient operation.
3. OTEC reliability of operation and freedom from maintenance will be compa-
rable to commercial refrigeration systems, which typically operate continu-
ously for many years without shutdown. Operating factors of 85 to 95% are
projected, compared with 50 to 70% for coal and nuclear plants.
4. OTEC operation will be safe and environmentally benign. Ocean basing frees
OTEC from the taxes and delays imposed on conventional power plants by
local governments opposed to power generation in their neighborhoods.
5. OTEC construction will employ facilities, procedures, and components that
are standard in marine construction. Construction time will be 2.5 to 3 years,
rather than the 6 to 10 years typical of coal and nuclear plants.
The preceding reasons combine to make the predicted costs of OTEC power
attractive compared with other practical energy supply alternatives of comparable
safety and environmental acceptability.
Because the thermal efficiency is low, OTEC operation requires the flow of
large amounts of ocean water through the power system per kilowatt of power
generated. This requirement in turn implies large heat exchangers, which must have
INTRODUCTION AND OVERVIEW 9
a low unit cost if the total system is to meet competitive cost standards. The technical
and design requirements to satisfy this criterion are discussed in the next section.
1.2.1.3 Basic Heat Exchanger Design Factors
The rate of heat transfer from one fluid through a dividing wall to another fluid is
governed by the following general expression:
where Q = heat transfer rate; U = specific heat transfer coefficient (kW/m2 C);
A = surface area (m2); T1= temperature of first fluid (C); T2 = temperature of second
fluid (C).
For the heat transfer rate from warm water to ammonia in the evaporator,
where Qe = evaporator heat transfer rate; Ue = heat transfer coefficient for the
evaporator; Ag = heat transfer area of the evaporator; Tww = warm-water tempera-
ture; Tae = ammonia temperature in the evaporator.
For the heat flow from ammonia to cold water in the condenser,
where Qc = heat transfer rate for the condenser; Uc = heat transfer coefficient for
the condenser; AC = condenser area; Tac = ammonia temperature in the condenser;
TCW = cold-water temperature.
Since the heat exchangers (HX) are of finite size and heat is transferred as
water flows over the HX surfaces, the temperature of the water leaving the
evaporator is lower than the temperature at the inlet. The ammonia boiling and
condensation temperatures are determined by the pressures in the evaporator and
condenser and are approximately constant.
The rate of heat transfer from water to ammonia varies with position in the HX;
therefore, appropriate average values must be used for these quantities. Further
elucidation is provided in Chapter 4.
The value of the coefficient U is dependent on the thermodynamic properties
of the fluids, the flow velocities, the fraction of ammonia vaporized at a particular
point in the heat exchanger, the pressures, the composition and construction of the
separator material that forms the bounding surface between the fluids, the character
of the surfaces on both sides of the separator (roughness, presence or absence of
scale, biofouling, etc.), and the detailed design and dimensions of the heat
exchanger. An analysis of the heat transfer process is given in Section 4.1.
As may be seen from Fig. 1-7, if a quantity of heat, Q, flows from water to
ammonia, it must pass first from the water interior to the separating surface.1 This
requires a temperature difference, Tw-Tsb, the magnitude of which depends on the
10 OCEAN THERMAL ENERGY CONVERSION
character of the flow at that point. This, in turn, depends on the local geometry of
the flow passage. The heat then flows through any buildup of scale plus biofouling
on the water side of the surface, where a further temperature drop, TsbTmo, occurs.
Similarly, the heat passes through the other resistances until it is finally absorbed
by the bulk ammonia flow. We then have:
it follows that
Eq. (1.2.7) to assess the relative importance of the terms on the right-hand side of
the equation. From this assessment, one can estimate the effect of changes in the
coefficients that could result from design improvements, changes in operating
conditions, or degraded heat transfer due to biofouling or scaling.
As a baseline, values of the heat transfer coefficients in SI units typical of the
current state of the art are listed here (English units are in parentheses):
h =W/m 2 C = (Btu/ft 2 hF)
x =m = (ft)
k =W/mC = (Btu/fthF)
\lhw =0.00018(0.001)
1 lhsb = 0 to 0.000088 (0 to 0.0005)
XA, * = 0.0015 (0.005); xTi = 0.00076 (0.0025)
k
A15052 =138 (8); k
AI3003 = 156
(90); k
Ti= 17 10
( )
\lhsa =0.0000(0.0000)"
\lha = 0.000088 (0.0005)
Ti = titanium
Al = aluminum (numerical subscripts are alloy designations).
With these values, we have for an aluminum HX with no biofouling,
l/U = 0.00018 + 0.00000 + 0.00001 + 0.00000 + 0.000088
= 0.000278
U = 3600 W/m2 C (630 Btu/ft2 h F).
Substitution of more optimistic or more pessimistic values in the formula leads
to the changes in performance shown in Table 1-1. The table shows that major
improvements in power output will be possible with foreseeable improvements in
heat transfer rates, and that biofouling effects will be minor if the fouling coefficient
is maintained below an average value of 0.0001, as expected from experimental
results.
1.2.1.4 Heat Exchanger Dimensions
The low heat transfer rates typical of OTEC systems impose a requirement for large
surface areas in the heat exchangers. For typical values of the heat transfer
where v is the flow velocity and t is the time. The quantity of heat transferred during
flow through the heat exchanger is then
where is the liquid ammonia density and Cp is the specific heat. Since t = z/v,
INTRODUCTION AND OVERVIEW 13
For example, if
(T w i n - T w out) =3-50C(6.3F)
(Tw-Ta) =5.56C(10.0F)
p M' = 0.824 kg/m3 (64 lb/ft3)
Cp = 0.96 kcal/kg (0.96 Btu/lb)
y = 0.0254m (1/12 ft)
v =0.91m/s(3ft/s)
U = 3620 W/m2 C (638 Btu/ft2 h F),
then
z = 8.23 m (27 ft).
Furthermore, since the volume rate of water flowing is yvx and x is the total
length of flow passage normal to the flow, x = 990 m (3250 ft).
Finally, if the inlet areas of water and ammonia passages are equal and the wall
thicknesses are (1/20) y, the total cross-sectional area of each heat exchanger for this
nominal 10-MWe (gross) module will be approximately 106 m2 (1140 ft 2 ). The
platform area required just for the heat exchangers in a 54-MWe (40-MWe [net])
OTEC vessel will then be approximately 572 m2 (6200 ft2) for the values of the
parameters given.
Thus, for the range of surface temperatures between 23.9C (75F) and 30.0C
(86F), corresponding to Ts of 19.4 to 25.6 degrees Celsius (35 to 46 degrees
Fahrenheit), the output varies from
This steep dependence of net power on water surface temperature shows that
OTEC cost per megawatt of net power output will have a pronounced minimum at
ocean sites of high average surface temperature. This provides a strong impetus for
focusing economic analyses of OTEC relative to other energy alternatives on the
construction costs and costs of delivered power of OTEC plants designed for
operation at sites of maximum ocean water temperature.
1.2.3 Water Ducting Subsystems
This section is concerned with the equipment and structures needed for drawing
warm and cold water from the ocean, directing it to the heat exchangers, and
returning it to the ocean. Water ducting is a major part of the OTEC system because
of the large volume of water that must be handled and the size and length of the
required cold-water pipe (CWP).
1.2.3.1 OTEC Cold-Water Pipe
General Requirements. Inherent in the OTEC concept is the use of cold
water drawn from depths to 1000 m (3300 ft) to cool and liquefy the vapor emerging
from the power plant turbine. The pipe and its attachment to the platform must be
designed to withstand the static and dynamic loads imposed by the pipe weight, the
relative motions of the pipe and platform when subjected to wave and current loads
of up to 100-year-storm severity, and the collapsing load induced by the water pump
suction. The CWP must be large enough to handle the required water flow with low
drag loss; it also must be of a material that will be durable in seawater and not
capable of forming corrosion or erosion products that would induce HX corrosion
or be environmentally unacceptable.
A brief discussion is presented of the factors that must be considered in
arriving at an optimum design for the CWP. The exposition is based on the analyses
made in connection with the preliminary design of a 40-MW floating OTEC plant
(George and Richards, 1980). The CWP requirements for a 50-MW plant resting
on the sea bottom near the shore (shelf mounted) are also discussed briefly (Ocean
INTRODUCTION AND OVERVIEW 17
We note that
Since
Engineering data on two 9.1-m- (30-ft-) diameter CWP designs of the types
discussed here are given in Section 4.2.
INTRODUCTION AND OVERVIEW 21
The first design employs 15-m- (50-ft-) long cylindrical sections (modules)
made of post-tensioned lightweight concrete. The modules are connected through
flexible joints having elastomeric pads of the type used between and under highway
bridge sections.
The density of concrete can be lowered by replacing the sand with lighter
materials such as fly-ash, without significant degradation in strength or suitability
for use in marine applications. This feature allows the concrete specific gravity to
be selected at an optimum value, 13% above that of seawater, which makes the
deployed weight of the pipe only that required to hold the pipe angle at small values
in the presence of ocean currents.
The second design uses a 910-m- (3000-ft-) long pipe made of concentric
fiber-reinforced plastic tubes with an internal low-density plastic (syntactic foam)
spacer. In this case, a weight is attached to the bottom of the slightly buoyant pipe
to maintain the pipe at small angles from the vertical in the presence of lateral
currents or platform motions.
The dynamic behavior of the CWP is determined by the longitudinal tension
in the pipe wall, the bending strength (stiffness) of the wall, the longitudinal mass
distribution, and the varying stresses imposed by the platform motions and ocean
currents. In the first approximation, the CWP may be represented as a stretched
string of uniform mass, which is supported at the top and subjected to a periodic
force produced by wave action. The tension in the pipe decreases linearly with
depth. If such a system is excited by a periodic force that is slowly increased from
zero frequency, at a particular frequency the pipe will begin to vibrate, and, with no
damping, the amplitude of the motion will increase at every cycle. This frequency
is called the resonant frequency for the first vibrational mode. If the frequency of
the periodic forcing function is now increased, the pipe motion will diminish to
nearly zero; however, with further increase in the forcing frequency to a value about
twice the first frequency, another resonance condition will occur, called the first
overtone or second normal mode. Further overtones will be di splayed as the forcing
frequency is progressively increased.
The vibrational amplitude depends on the frequency of the forcing function
and, with no damping, will assume extreme values for every instance in which the
forcing frequency equals the frequency of one of the normal modes. With damping,
energy is absorbed in proportion to the lateral vibrational velocity of the string, so
that a limiting amplitude of vibration is reached at resonance conditions.
For a CWP suspended from a platform that is subject to wave motion, the
forcing frequency will not be a single value but will be distributed over a spectrum
of frequencies defined by the sea state, which will also be time dependent; however,
for a given sea state, a narrow frequency range will dominate, and the CWP will
vibrate in an overtone mode that most closely matches the exciting frequency. For
the 100-year-storm condition in the equatorial Atlantic Ocean, the dominant
frequency will be 1/10 to 1 /13 Hz, that is, a wave period of 10 to 13 s. In Puerto Rico
and Hawaii, the wave period during the 100-year-storm will be about 13 s.
22 OCEAN THERMAL ENERGY CONVERSION
1.2.4.1 Hydrogen
Hydrogen is an excellent fuel that burns with high efficiency and produces only
water as a combustion product. These characteristics have caused it to be advocated
as the most desirable fuel to replace hydrocarbons in the future; however, hydrogen
has two severe drawbacks: a very low density, both as a gas and as a liquid, and an
extremely low boiling point ( 265C, 445F). Cryogenic storage is required if
hydrogen is to be used in liquid form. The estimated costs of liquefaction, storage,
and transport of hydrogen from an OTEC plantship to users on land are high enough
to make it unattractive in the near future to produce OTEC hydrogen as a fuel for
motor vehicles or for power plants; however, preliminary design estimates indicate
that OTEC liquid hydrogen could compete with other production options for
applications that require liquid hydrogen per se, such as the space shuttle or
hypersonic aircraft.
1.2.4.2 Ammonia
An attractive method of storing and transporting OTEC hydrogen is to combine it
with nitrogen on the plantship to form ammonia, NH3, which can be easily liquefied,
transported, and stored by standard methods and equipment. Liquid ammonia is
nine times as dense as liquid hydrogen and can be stored at ambient temperatures.
Combustion of a liter of liquid ammonia produces 30% more heat than combustion
of the same volume of liquid hydrogen. When ammonia burns, only water and
nitrogen, the principal constituents of air, are formed as products; therefore,
ammonia, like hydrogen, can be a fuel for the future because no pollutants are
produced when it burns. Engine tests have demonstrated that ammonia is an
excellent fuel for internal combustion engines, burning with high efficiency with
an octane number of 111 (Starkman et al., 1966).
Ammonia is now produced commercially in multimillion-ton quantities by
processes that use natural gas as a source of hydrogen. Ammonia is used worldwide
as a fertilizer and is a major feed stock for the production of other nitrogen-rich
fertilizers or plastics such as polyurethane. Thus, facilities and distribution systems
are available for ammonia that would be suitable for direct introduction of OTEC
ammonia into world markets if natural gas prices were to rise to values that would
make OTEC ammonia competitive (Avery, 1988).
In the preliminary design of a baseline 40-MWe OTEC plantship, the electric
power generated is used for on-board ammonia synthesis. The demonstration plant
24 OCEAN THERMAL ENERGY CONVERSION
produces 103 metric tons (114 tons) per day of ammonia, which is stored on board
for shipment to shore at approximately monthly intervals. A conceptual design was
also prepared for a 325-MWe commercial plant that would produce 1100 metric
tons (1200 tons) per day of ammonia. It was estimated that ammonia from such
plants would be cost competitive with ammonia from natural gas if the natural gas
cost rose to about $6.00 per GJ ($5.70 per million Btu). Details are presented in
Chapter 4.
1.2.4.3 Methanol
The energy transfer method that offers the most promise for OTEC to become an
early contributor to world energy supplies is the production of methanol (CH3OH)
on OTEC plantships (Avery et al., 1985). OTEC methanol could be a competitively
priced substitute for petroleum-based fuels, even at 1989 gasoline prices. Methanol
is a liquid at ambient temperatures. It burns cleanly and has an octane number of
110. Extensive tests with standard automobiles have shown that it can replace
gasoline as a fuel with only minor modifications in operational factors and give a
lower cost per kilometer than premium gasoline fuel (Fisher, 1984).
Methanol is made by combining two volumes of hydrogen with one volume
of carbon monoxide (CO) in the presence of a suitable catalyst. CO is formed by the
reaction of carbon with oxygen. The methanol synthesis reactions use the oxygen
as well as the hydrogen of OTEC water electrolysis, with a corresponding reduction
in the product cost. The low cost of coal shipment makes it commercially attractive
to transport coal to the OTEC plantship to supply carbon for CO production. A
design of an OTEC plantship with nominal 160-MWe output power that produces
1750 tonnes (1925 tons) per day of methanol is described in Chapter 4 (Ebasco and
Rockwell, 1984).
1.2.4.4 Energy Transfer from Grazing OTEC Plants
OTEC plantships designed to produce ammonia, methanol, or other energy prod-
ucts will cruise slowly (graze) in regions of the tropical oceans where T exceeds
22 degrees Celsius (40 degrees Fahrenheit). Energy transfer will involve shipboard
storage of the energy product for periods of about 1 month, followed by transfer of
the product to a tanker for transport to world ports where the product will be stored
for transshipment to the ultimate consumer. The basic equipment and procedures
required for this method of energy transfer are in general commercial use. Some
development will be necessary for shipboard operation. The requirements are
discussed in Chapter 4. In brief,
1. Electrolyzers now in commercial use must be scaled up to a suitable size and
efficiency for economical production of hydrogen on OTEC plantships.
2. Commercial air-separation plant subsystems must be arranged for shipboard
operation as integral units in OTEC ammonia or methanol plants. For methanol
production, scale-up of the Rockwell molten carbonate gasifier is necessary
(see Section 6.4).
INTRODUCTION AND OVERVIEW 25
support an OTEC plant of cost-effective size. The islands of Oahu in Hawaii and
Puerto Rico have attractive sites for moored OTEC plants that could contribute to
U.S. needs. Similar opportunities exist on other islands in the Caribbean and
throughout the Pacific. If underwater power transmission for distances of about 160
km (100 miles) can be proved feasible, OTEC plants could also be placed near the
edge of the continental shelf in the Gulf of Mexico and at other sites bordering the
Atlantic, Pacific, and Indian oceans (Morello, 1978; Garrity and Morello, 1978;
Garrity et al., 1980).
Successful deployment and operation of a moored OTEC plant requires
development of a mooring or station-keeping system that will hold the plant on
station at offshore sites where the water depth exceeds 1100 m (3600 ft), which is
needed to leave ample clearance for the CWP intake. The mooring must also be
compatible with the power-cable system designed to bring electric power from the
OTEC plant to the substation on land. Several methods have been devised that seem
suitable for mooring or position control of an OTEC platform sited where the water
depth is 1100 m (3600 ft) or more. The mooring studies have included a number of
platform types and sizes and have addressed wave and wind conditions predicted
for the worst storm expected to occur at the site during a 100-year period. Methods
of rotating the platform to the optimal heading during the storm were included.
Differential traction of the mooring cables and use of thrusters mounted at the
corners of the platform were investigated (Trimble and Robidart, 1978). A "watch
circle"3 no greater than 5% of the mooring depth was imposed as a design
requirement to ensure compatibility with the power-cable requirements.
Two potential designs of mooring lines for a multiline mooring system that
combines features of earlier studies are shown in Fig. 1-9 (Ross and Wood, 1981).
Three potential power-cable support methods are shown in Fig. 1-10 (Schultz et al.,
1981). Several concepts have been proposed that address the combined mooring
and power transmission requirements, but an optimal system has not been defined.
The perceived technical difficulties of moored floating plants led to a diversion of
Department of Energy (DOE) program emphasis after 1981 to shelf- or shore-
mounted concepts for this OTEC application.
The equipment for the transfer of OTEC power to shore includes the power-
cable mounting, power-conditioning equipment, switching gear, operator's control
station, and safety equipment. In the 40-MWe demonstration vessel design, the total
electric power transfer system occupies a space 33 m (108 ft) wide and 21 m
(70 ft) long.
FIG. 1-9. Diagram of mooring options for an OTEC barge (Ross and Wood, 1981).
FIG. 1-10. Diagram of power cable deployment options for moored OTEC power plant (Schultz et al.,
1981).
totaling several hours per year at sites within 10 of the equator in the Atlantic
Ocean. For a severe storm, when the wave height reaches 3.5 m (12 ft), the ship
power plant is shut down and the propulsion power is supplied by standby diesel-
electric generators. Dicsel-electric-driven thrusters mounted at the four corners of
28 OCEAN THERMAL ENERGY CONVERSION
the OTEC platform, rated at a maximum power of 2 MWe each (2500 hp), that is,
8 MWe total, are used to maintain heading and ship stability under these extreme
conditions. Under the normal grazing operation, at an average 0.4-knot speed, a
total thruster power of 1.4 MWe supplied by the OTEC power plant suffices.
Thrusters with the desired power and ability to direct the thrust in any desired
horizontal direction (azimuthing capability) are commercially available. A discus-
sion of the requirements is given in Chapter 4.
of these systems to the major energy needs of the United States or other
developed countries is small, except for their inputs to the technical and
commercial development of OTEC as a major energy source; however, such
small systems can be cost effective at many island sites and could induce a total
demand large enough to generate commercial interest. Indeed, such interest
appears to be attracting Japanese involvement.
This overview and the remaining chapters focus on defining the technology
that is needed for OTEC to meet the requirements of Category 1; however, funding
support in the United States, after initial emphasis on Category 2, turned to Category
3 and has been directed to the investigation of specific component or subsystem
designs. Thus, conceptual designs of complete OTEC systems are available for only
eight U.S. systems. Of these, three are for moored installations, three are for shelf-
mounted systems, and two are for plantships. Preliminary engineering designs were
completed for only one 40-MWe plantship, one moored 40-MWe power plant, and
one 50-MWe shelf-mounted system.
Land-based (shelf-mounted or onshore) OTEC installations, which are site
specific, are discussed in Chapters 4 and 5.
FIG. 1-11. Alternative platform configurations for moored OTEC power plants (Waid, 1978).
3. A hull configuration is chosen that will provide space and support for the
arrangement of subsystems defined in Step 2 and that satisfies naval architec-
ture and marine engineering requirements such as the length-to-beam ratio,
buoyancy, pitch and roll angles, angular excursions of the joint between the
CWP and platform, and survival strength. Materials, facilities, and construc-
tion procedures are considered from the standpoint of minimizing cost and
schedule, and a provisional design concept is selected.
4. Weights and volumes of the light ship and fully loaded platform are assessed,
reflecting the inputs from Step 3. Ballasting requirements are calculated that
will adjust the displacement and metacentric height to appropriate values in
operational and survival conditions. If incompatibilities are found, the design
process is recycled until a satisfactory design is achieved.
The platform-CWP combination must be designed so that angular motions at
the joint between the CWP and platform will be small in normal operation and will
not exceed safe limits, even with waves of the magnitude predicted for a 100-year
storm.
The volume of water flowing to the heat exchangers implies a design in which
the water pumps are mounted so that the water exhausts at an elevation above sea
level that balances the head required to overcome pressure drops in the heat
exchanger cycle. To minimize pumping power costs, water flow velocity in the
ducts should be moderate. The ducts and heat exchanger bays for a power module
are designed to form a compact unit associated with the corresponding pump
outflow, so that they become an integral part of the structural configuration of the
ship.
As in other aspects of OTEC design, thorough systems engineering is required
to achieve a platform design that will be optimal for performance, durability, and
maintainability at minimal cost. The major aspects will be summarized here. The
design details are discussed in Chapter 4.
Platform Dimensions. The platform dimensions are defined by the volume
requirements of the major subsystems and the ways in which they may be combined
to form a practical total design. The dimensions and volumes of these subsystems
may be estimated by considering the size requirements defined for the baseline 40-
MWe plantship. These resulted from a systems integration and optimization
program (George and Richards, 1980).
The platform is a box structure 135 m (443.5 ft) long, 43 m (140 ft) wide, and
27 m (89 ft) deep. A sketch of the baseline barge and the general layout of the
baseline plant are shown in Figs. 6-56 and 6-57 in Chapter 6. Details of the design
are presented in Section 6.5.1.
1. The baseline power plant consists of four modular units of nominal 10-MWe
net output. Each module includes heat exchangers and associated structures,
ammonia pump, demister and turbine, and electric generator.
2. The water ducting subsystem includes the CWP assembly with a pipe-to-
platform joint and supporting structure, warm-water intakes and pumps, and
32 OCEAN THERMAL ENERGY CONVERSION
ducts to carry water to the heat exchangers and afterward discharge it to the
ocean in a manner that will be environmentally satisfactory. The cold-water
pumps direct water into a moon pool at the top of the CWP.
3. Transfer of OTEC energy from the bus bar on the plantship to shore is by
conversion of electrical energy to stored chemical energy in the form of
ammonia. The baseline design assigns an area of 700 m2 (7500 ft2) for this
subsystem. The electrolysis system, ammonia plant, and ammonia storage and
transfer gear are included in this volume. The area and volume requirements
of the power subsystem for direct transfer of electric power to shore in the
moored plant configuration, including mooring and power conditioning space,
are estimated to be the same for the 40-MWe moored baseline vessel as for the
energy conversion plant.
4. Crew accommodations are provided for 40 people, including space for visitors
and supporting facilities. The personnel are housed in a five-story hotel. Area
for shops and additional facilities is provided on lower decks.
5. Wing walls extending the length of the platform are required to provide
strength to resist bending and twisting loads. For the baseline design these are
box beam structures.
The total platform area of the baseline barge is 5770 m2 (62,100 ft2) not
including the sponsons. The main deck is 23.5 m (77 ft) above the keel. Hull volume
not occupied by the power plant equipment, water ducting, and energy transfer
equipment is allocated to machinery, fuel storage, ballast, electrical gear, position-
ing control equipment, safety equipment, and miscellaneous items. The positions
of the various subsystems are shown in Fig. 6-56.
The 40-MWe ammonia plantship design has been used as a baseline for
preliminary design studies of a 182-MWe (160-MWe [nom]) plantship (Ebasco and
Rockwell, 1984). A layout drawing of the methanol plantship is shown in Fig. 6-
39. The vessel is 275 m long, 100 m wide, and has a draft of 20 m (Richards et al.,
1984; Avery, 1984). Details are presented in Section 6.4.7.
Comparison of the dimensions of the 160-MWe (nom) plantship with the 40-
MWe (nom) baseline shows that more efficient use of the platform area assigned
to the cold-water ducting and wing wall structures is achieved in the larger
plantship; however, no specific effort was made to minimize packaging for the hotel
and miscellaneous structures, in scaling to 160 MWe. The power plant area was
based on the use of the 10-MWe modules of the baseline design and remained
constant. Thus, the area assigned is much larger than necessary.
Construction Materials. The technology and materials for construction of
OTEC floating platforms of either steel or concrete are available at many shipyards
in the United States and other countries. Although steel is the predominant choice
for ship construction, concrete with reinforcing steel and/or post-tensioning is more
suitable for OTEC barges because of several factors:
1. The hull cost per unit of power output is significantly less for concrete
construction.
INTRODUCTION AND OVERVIEW 33
2. The greater weight and volume of concrete, which increase ship drag, are not
a significant drawback for moored or slowly moving OTEC barges.
3. Since considerable ballast is needed to compensate for the buoyancy of
submerged OTEC heat exchangers, the greater weight of the concrete hull
simply reduces the amount of ballast needed.
4. Concrete is compatible with aluminum, but steel requires special precautions
to avoid corrosion induced by electrolytic action or by deposition of corrosion-
inducing particles of iron or rust on aluminum heat exchanger surfaces.
5. Concrete is durable in seawater, whereas steel ships must be returned to
drydock at intervals of approximately 5 years for rust removal and reapplica-
tion of rust-prevention coatings.
These factors have led to the selection of concrete hull designs for almost all
of the proposed OTEC installations.
Shipyards suitable for the construction of floating OTEC plants are available
on the east and west coasts of the United States, along the Gulf of Mexico, and in
other maritime countries. New graving docks would usually be required but would
be a small addition to the total investment. A listing of suitable facilities is presented
in Chapter 4.
only withstand the corrosive action of seawater but also must not contaminate the
outflow with dissolved chemicals hazardous to marine life.
The initial review of this program element led to the establishment of a
research and development program under Argonne National Laboratory direction
to furnish test data on the durability of candidate aluminum alloys and to provide
further data on copper and stainless steel alloys, which might offer intermediate cost
advantages (Kinelski, 1979; LeQue, 1979). Test programs were set up, principally
at the Naval Coastal Systems Center, Panama City, Florida; at the LeQue Center for
Corrosion Research, Wrightsville Beach, North Carolina; at the Center for Energy
and Environmental Research, San Juan, Puerto Rico; and at the Sea Coast Test
Facility of the University of Hawaii. The last two had access to warm ocean water
typical of OTEC operating conditions. Five years of testing in Hawaii proved that
several aluminum alloys showed corrosion rates low enough to qualify them for 30-
year life in OTEC heat exchangers. Since the life-cycle cost of aluminum heat
exchangers will be much lower than the costs of other alternatives, the OTEC
system cost estimates discussed later are based on the use of aluminum (Panchal et
al., 1985). The demonstration that high-cost titanium heat exchangers would
not be required was a major result of this program. The data are presented in
Chapter 4.
of this work, a practical method of OTEC biofouling control is now available. It has
been shown that injection of 70 parts per billion of chlorine for 1 hid into the warm-
water flow to the evaporator effectively prevents film formation. As of July 1986,
heat exchanger test samples had been exposed to seawater with this chlorine
concentration for more than 1000 d, with no significant reduction in the heat transfer
coefficient due to biofouling. The chlorine added is one-twentieth of the amount
considered environmentally acceptable by the U.S. Environmental Protection
Agency. There was no biofouling in the condenser test samples exposed to cold-
water flow; therefore, there was no need for chlorine addition (Berger and Berger,
1986).
Figure 1-12 displays biofouling test results for a typical experiment using
warm seawater with chlorine injection, and for a control run in which fouling was
allowed to build without chlorine injection until Rf reached the value 5 x 10 -4 m2
h F/Btu, after which the heat exchanger surface was cleaned and the process
repeated.
The research and development program also demonstrated that biofouling can
be controlled by physical means, including brushing and ultraviolet and ultrasonic
radiation; however, these methods are less attractive to use and are not likely to be
adopted unless chlorine or other biocides are arbitrarily, or as the result of new
evidence, ruled to be unacceptable.
The biofouling program also included studies of the biology of slime forma-
tion on surfaces exposed to seawater. The process involves an initial phase in which
a bacterial film is deposited on the heat exchanger surface. This film provides
sustenance for marine organisms, which gradually build up a layer that covers the
surface. When this stage is reached, growth proceeds at a relatively fast, approxi-
mately constant, rate. Experiments show that the value of Rf is directly proportional
to the film thickness (Liebert et al., 1981).
Another important result of the biological investigations is that no significant
differences are found in the organisms that cause fouling at sites in Hawaii, Puerto
Rico, and the Gulf of Mexico. This result gives confidence that biocontrol measures
that are effective in Hawaii will be applicable throughout the tropical ocean area
(Sasscer, 1981; Liebert et al., 1981).
FIG. 1-12. Change of fouling coefficient with time in HX tubes exposed to warm seawater. (Top) With
chlorine addition of 70 ppb/h per day. (Bottom) Without chlorine but cleaned when Rf reached 5 x 10-4
ft2 h F/Btu (Berger amd Berger, 1986).
in diameter were in use on land. Thus, facilities were available or could readily be
assembled that could be used to build pipe segments of these materials that could
then be joined to form pipes of the required length. The major questions that arose
were the following:
1. How do we determine the dynamics of the CWP- platform system as a function
of the design variables?
2. Would the CWP-platform loads be a determining factor in the total system
design? For example, would a submerged or spar design for the platform be
required for a feasible design of the CWP to be achieved?
INTRODUCTION AND OVERVIEW 39
FIG. 1-13. Design of platform of 160-MWe (nom) OTEC methanol plantship (EBASCO and
Rockwell, 1984).
Many teams of oceanographers and biologists were recruited early in the OTEC
program to compile information that could serve as a data base for assessing OTEC
performance and environmental interactions. Regions investigated in some detail
included the Gulf of Mexico, Hawaii, Puerto Rico, and the tropical Atlantic Ocean.
Available data were assembled on temperature, salinity, winds, currents, and
marine life, from the surface to a depth of 1000 m (3280 ft). To the extent that funds
and personnel were available, additional measurements were made at specific
points of interest. This information has been invaluable in judging the potential
interactions of OTEC with the environment.
The initial program in this field was designed to provide the basic marine biological
information needed for OTEC design and performance evaluation. Topics assigned
for investigation included the identification of marine organisms involved in
biofouling, description of the fouling process, effect of operational site on fouling,
measurement of biofouling rates, measurement of the reduction of heat transfer as
a function of biofouling buildup, effectiveness of various chemical and physical
methods of biocontrol, and development of facilities, instruments, and evaluation
procedures required for the different investigations.
The program has reaffirmed the observation that the quantitative description
of the marine world and its interaction with ocean-based structures, processes, and
materials is an infinite task. Nevertheless, the needed basis for the design of OTEC
power systems that will operate with high performance in the tropical ocean regions
suitable for OTEC has been established.
The results of the studies of heat exchanger biofouling were discussed in
Section 1.3.
In summary,
1. Fouling of heat exchangers occurs slowly under OTEC evaporator operating
conditions and does not occur in the cold environment of condenser operating
conditions. Biofouling can be prevented by injecting chlorine 1 h/d into the
inlet water at a concentration of 70 parts per billion. Physical methods of
biocontrol are also available but are less cost effective.
2. Tests in Puerto Rico, the Gulf of Mexico, and Hawaii, which show similar
results, provide evidence that biofouling is not site specific at deep-water
tropical sites suitable for OTEC operation.
3. Concerns that biofouling could seriously degrade OTEC performance and
operating cost have been allayed.
4. Materials have been identified and tested that would satisfy at reasonable cost
the OTEC requirements for the 30-year life of the power system components,
platforms, and CWPs.
44 OCEAN THERMAL ENERGY CONVERSION
depths is warmed an equal amount in passage through the condensers. The two
flows are mixed and are then discharged at an appropriate depth. For the baseline
40-MWe moored plant design, the mixed flow emerges downward at a depth of
about 76 m (250 ft) through eight pipes 4.6 m (15 ft) in diameter. The temperature
of the discharged water is 15.5 1.7C(60 3F), and the exhaust velocity is 2.1
m/s (6.8 ft/s). The momentum of the flow and its lower density than the surrounding
water cause the water column to descend to a depth of about 200 m (650 ft) before
it equilibrates with the surrounding water (see Chapters 4 and 5). No measurable
effect on the water temperature at the surface is expected from operating a single
OTEC plant under actual conditions.
If moored plant operation were established and continued in a completely still
environment, the water emerging downward would gradually induce a large-scale
circulation pattern that would ultimately get to the surface; however, since currents
of fluctuating intensity and direction are always present in the ocean, it appears that
steady circulation patterns would not have a chance to become established with
plants of commercial size. Surveys of the flow from actual plants will be needed to
provide a detailed picture of the impact of moored plant operation on the hydrody-
namic and biological environments of the plants.
Grazing OTEC plantships will be sited in regions of the tropical oceans where
an adequate T is available. The plants will cruise within an ocean region of several
hundred square kilometers per plant at speeds of about 1.26 m/s (0.5 knot). If
constructed in accord with the present designs, these plants will discharge the
outflow at a depth of 20 m (65 ft), and the outflow will slowly descend to a depth
of about 200 m (600 ft) before equilibrating. A small part of the outlet flow will
remain in the mixed layer near the surface and could stimulate the production of
marine life, as is characteristic of tropical regions near Peru where upwelling brings
nutrient-rich deep water to the surface. The lack of oceanographic analysis of the
flow patterns and the absence of experimental data prevent quantitative prediction
of the effects.
The potential increase in marine life associated with OTEC plantship opera-
tion is expected to be beneficial, although it could lead to the need for somewhat
more vigorous methods to control biofouling of the OTEC heat exchangers. The
needed data can be acquired when the first commercial OTEC plantships begin
operation (Laurence and Roels, 1977).
can be used for estimates of the long-term effects of OTEC plant operation on the
distribution of the plant outflow and on ocean surface temperatures. Using a one-
dimensional model, Martin and Roberts (1977) derived the temperature and flow
impacts of operation of 100 and 1000 moored 200-MWe plants, uniformly
distributed at spacings of 107 and 34 km in the 1 million square kilometer area of
the Gulf of Mexico. Operation of 1000 200-MWe plants in the Gulf of Mexico
would cause changes in the mixed layer that would stabilize after about 2 years with
a decrease of the annual average surface temperature of about 1.3C. With 100
plants, the decrease in surface temperature would be only 0.05C. (The electric
power production of 1000 200-MWe plants would be equal to 25% of the total U.S.
electric power demand in 1990.) In this one-dimensional model, the principal effect
of the OTEC operation is to produce a flat oval of mixed effluent water centered at
about 850-m depth, which steadily increases in temperature. The predicted gain in
temperature in this zone is about 0.3C/year for the 1000-plant case and 0.03C/
year for the 100-plant siting. In actual operation, cold water flowing into the Gulf
of Mexico would displace the warmer water at the 1000-m level, so that net plant
output would be determined by the rate of flow of cold water into the Gulf. Similar
conclusions appear reasonable for dense siting of OTEC plants in other tropical
ocean areas; however, definitive studies have not been done. A study by Brin of the
effect of continuing OTEC operation on the cold-water reservoir below 1000 m in
depth showed that the impact would be insignificant if OTEC plants were sited to
produce no more than 0.2 MWe/km2 of ocean surface area (Brin, 1981).
Refinement of the models to include three-dimensional analyses and experi-
mental data from at-sea plant operations are required for precise estimates (Allender
et al., 1978). It is clear from the present studies that the thermal and hydrodynamic
impacts will be small for operation of individual plants and that large numbers of
OTEC plants can be operated without causing environmental concerns. Decisions
on optimal plant spacing for maximum long-term power production can await data
from multiplant operational experience.
A more extensive discussion of environmental impacts of OTEC operation is
given in Chapter 9.
The investment requirements and operating costs for OTEC systems of demonstra-
tion size were determined in the OTEC preliminary design and conceptual design
programs funded by the DOE. This information and data from French, Japanese,
and Taiwanese programs provide a base for estimating investment and operating
costs for commercial plants and plantships. The most complete cost assessments
were made in the preliminary design of a land-based OTEC power plant by the
Ocean Thermal Corporation, and in the programs resulting in baseline designs of
barge-mounted OTEC plants that were done by the Applied Physics Laboratory of
The Johns Hopkins University. The land-based plant would be sited in Hawaii on
the island of Oahu. The floating plants include a moored plant to be sited off Punta
Tuna, Puerto Rico, and grazing OTEC plantships sited near the equator in the
Atlantic Ocean. The cost data for OTEC systems are presented in Chapter 7.
From the plant investment and operating cost data for an energy production system,
an investor can estimate the sales price of power or products that will return an
attractive profit to a private investor or allowable return to a publicly owned
enterprise. This sales price represents the result of an in-house assessment of factors
that include: perceived risk, projections of future markets, government subsidies
(for example, government-supported research and development, government-
supplied facilities, depletion allowances), tax incentives, financing options, and
other factors. Without knowledge of these proprietary factors, unbiased judgments
cannot be made in comparing the quoted prices of power or fuels from alternative
energy systems. A financial analysis procedure devised by Mossman (1988), based
primarily on plant investment, that uses the same guideline to estimate the sales
price that would return an acceptable profit for each energy production system
allows a valid comparison to be made of the relative commercial attractiveness.
This procedure eliminates distortions and misunderstandings caused by failure to
include the effects of government subsidies that differ widely among the various
options.
The financial analysis procedure and investment data to rate systems proposed
to meet future requirements for fuels and power are presented and compared in
Chapters 7, 8, and 9. The studies show that OTEC systems will be commercially
attractive when the product costs are compared with the costs of supplying motor
vehicle fuels from conventional systems. An investment in OTEC methanol
plantships with total capacity sufficient to replace all U.S. gasoline derived from
imported petroleum is estimated to provide investors an annual return after taxes of
38% on their equity. The assessment is based on a comparison of OTEC investment
needs with the investment requirements, without subsidies, of existing commercial
48 OCEAN THERMAL ENERGY CONVERSION
and proposed nonsolar options that must satisfy long-term requirements for
environmental acceptability and safety.
NOTES
1. Heat is not a substance. Therefore, it is not correct to speak of heat flowing from one
position to another; however, it is pedagogically useful to describe the process in this
manner. For an interesting discussion of this point, see Fenn (1982).
2. In the floating 40-MWe baseline design, the CWP diameter was not chosen to minimize
system costs but to demonstrate a CWP in the pilot plant test that would be the maximum
size considered feasible to construct with facilities available in 1979.
3. The tension in the mooring lines must be adjusted so that the ship cannot move from the
design surface position a distance more than 5% of the mooring depth.
4. Parallel studies were made by Basar et al. (1978); however, they assumed a fixed
connection between the CWP and the platform, which made their conclusions invalid
for platforms with a flexible CWP joint.
5. Significant wave height is the average height of the highest 10% of the waves occurring
during a storm of specified duration.
REFERENCES
Allender, J. H., J. D. Ditmars, R. A. Paddock, and K. D. Saunders, 1978. "OTEC physical
and climatic environmental impacts: An overview of modeling efforts and needs." Proc.
5th Ocean Thermal Energy Conversion Conf., Miami Beach, Fla., Feb., III-165.
Avery, W. H., 1984. "Methanol from ocean thermal energy." Johns Hopkins APL Tech. Dig.,
5, 159.
; 1988. "A role for ammonia in the hydrogen economy." Int. J. Hydrogen Energy, 13,
761.
, R. W. Blevins, G. L. Dugger, and E. J. Francis, 1976. Maritime and construction
aspects of ocean thermal energy conversion (OTEC) plant ships. Johns Hopkins Univ.
Applied Physics Lab., SR 76-1B.
, J. D. Richards, and G. L. Dugger, 1985. "Hydrogen generation by OTEC electrolysis
and economical energy transfer to world markets via ammonia and methanol." Int. J.
Hydrogen Energy, 10, 727.
BARDI, 1982. Coal to methanol study using OTEC technology. Brown and Root Develop-
ment, Inc. (BARDI).
Basar, N. S., J. C. Daidola, and N. M. Maniar, 1978. "OTEC ocean systems evaluation."
Proc. 5th Ocean Thermal Energy Conversion Conf., Miami Beach, Fla., Feb., IV-15.
Beck, E. J., 1975. "Ocean thermal gradient power plant." Science, 189, 293.
Berger, L. R., and J. A. Berger, 1986. "Countermeasures to microbiofouling in simulated
ocean thermal energy conversion heat exchangers with surface and deep water in
Hawaii." Solar Energy Update: Final Issue, SFU-86-12, 31.
Bretschneider, C. L., 1977. "Operational sea state and design wave criteria: state of the art
of available data for U.S. A. Coasts and equatorial latitudes."Proc. 4th Annual Conf. on
Ocean Thermal Energy Conversion, New Orleans, March, IV-61.
, and E. E. Tamaye, 1977. "Hurricane wind and wave forecasting techniques." Univ. of
Hawaii Look Lab., 6, No. 1.
, 1978. "Operational sea state and design wave criteria for potential OTEC sites." Proc.
5th Ocean Thermal Energy Conversion Conf., Miami Beach, Feb., IV-17 & IV-236.
INTRODUCTION AND OVERVIEW 49
, 1979. "Hurricane design winds and waves and current criteria." Univ. of Hawaii Look
Lab. Report No. 79-45.
Brin, C., L981. Energy and the oceans. Ann Arbor Publishers, Inc., Butterworth Group,
Chapter 8.
Carnot, S., 1824. "Reflexions sur la puissance motrice du feu et sur les machines propres a
developper cette puissance." Paris, Bachelier, Annales Scienufiques de I 'Ecole Normal
Superieure, 2, No. 1, 383 (1872).
Castellano, C. C., 1981. "Overall OTEC-1 status and accomplishments." Proc. 8th Ocean
Energy Conf., Washington, D.C., 2, 971.
Cichanski, W., and R. F. Mast, 1979. "Design of a concrete cold water pipe for ocean thermal
energy conversion (OTEC) systems." Proc. Offshore Technology Conf., Houston, Tex.,
11, 1653.
Cichanski, W., and J. S. O'Connor, 1983. "Development of a concrete cold water pipe for
ocean thermal energy (OTEC) systems." in Alternate energy sources III, Washington,
D.C.: Hemisphere Publishing Corp., p. 321.
Claude, G., 1930. "Cold water pipe for ocean thermal energy conversion (OTEC) systems."
Mechanical Engineering 52, 1039.
Det Norske Veritas, 1981. "Rules for the design, construction and inspection of fixed
offshore structures." Oslo.
Ditmars, J. D., and R. A. Paddock, 1979. "OTEC physical and climatic impacts." Proc. 6th
OTEC Conf., Washington, D.C., June, 13.11.
Donnelly, H. L., J. T. Stadter, and R. O. Weiss, 1979. "Cold water pipe verification test."
Proc. 6th OTEC Conf., Washington, D.C., 1, 6.2-1.
Ebasco Services, Inc., and Rockwell International Corp., 1984. "Coal to methanol OTEC
plantship study using the Rockwell molten carbonate gasification system." Johns
Hopkins Univ. Applied Physics Lab., APL Contract No. 601863-L, March.
Fenn, J. B., 1982. Engines, energy and entropy. New York: W. H. Freedman and Co.
Fisher, M., 1984. Methanol fuel program. Bank of America, San Francisco, Cal. (internal
publication).
Garrity, T. F., and A. Morello, 1979. "A theoretical study of technical and economic
feasibility of submarine cables for OTEC plants." Proc. 6th OTEC Conf., Washington,
D.C., 1,7.1.1.
Garrity, T. F., R. Eaton HI, T. Dalton, C. Pieroni, and J. P. Walsh, 1980. "Design, test and
commercialization considerations of OTEC pilot plant riser cables," Proc. 7th Ocean
Energy Conf., Washington, D.C., 3, 3.5-1.
George, J. F., D. R, Richards, and L. L. Peroni, 1978. A baseline design of an OTEC plantship.
Vol. A: Detailed report. Johns Hopkins Univ. Applied Physics Lab., SR-78-3A.
George, J. F., and D. Richards, 1980. Baseline designs of moored and grazing 40-MWe
OTEC pilot plants. Johns Hopkins Univ. Applied Physics Lab., JHU/APL SR-80-1A.
, 1981. "Model basin tests of a baseline 40 MWe OTEC pilot plant." Proc. 8th Ocean
Energy Conf., Washington, D.C., June, 77.
Gershunov, E. M., Y. H. Ozudogru, and J. M. Betts, 1981. "Analysis of the up-ending
problem of OTEC-1 cold water pipe." Proc. 8th Ocean Energy Conf., Washington,
D.C., June, 2, 991.
Hartwig, E. O., 1981. "OTEC environmental biological oceanographic program." Proc. 8th
Ocean Energy Conf., Washington, D.C., June, 507.
Hawiian Dredging and Construction Co., 1982. OTEC cold water pipe at-sea test program.
Hawaiian Dredging and Construction Co. Design Report No. 1.
50 OCEAN THERMAL ENERGY CONVERSION
Haynes, H. H., and R. D. Rail, 1977. "Concrete structuresfabrication methods." Proc. 4th
Annual Conf. on Ocean Thermal Energy Conversion, New Orleans, La., V-70.
Hove, D. T., and P. B. Grote, 1980. "OTEC CWP baseline designs." Conf. Proc. 7th Ocean
Energy Conf., Washington, D.C., June, 1 & 2, 3.3.1.
Jirka, G. H., J. M. Jones, and F. E. Sargent, 1981. "Intermediate field plumes from OTEC
plants: Predictions for typical site conditions." Proc. 8th Ocean Energy Conf., Wash-
ington, D.C., June, 475.
Kincaide, W. J., 1981. "Advanced alkaline electrolysis systems for OTEC." Proc. 8th Ocean
Energy Conf., Washington, D.C., 685.
Kinelski, E. H., 1979. "Biofouling, corrosion and materials overview." Proc. 6th OTEC
Conf., Washington, D.C., June, 2, 12.1.
, 1982. "OTEC biofouling, corrosion and materials program." Conf. Proc. 7th Ocean
Energy Conf., Washington, D.C., June, 1, 5.1.
Konopka, A., N. Biederman, B. Talib, and B. Yudow, 1977. "Alternative forms of energy
transmission from OTEC plants." Proc. 4th Annual Conf. on Ocean Thermal Energy
Conversion, July, 3, 47.
Laurence, S., and O. A. Roels, 1977. "Potential mariculture lead of sea thermal power
plants," Proc. 4th Annual Conf. on Ocean Thermal Energy Conversion, New Orleans,
La., March, III-21.
LeRoy, R. L., 1983. "Industrial water electrolysis: past and future." Int. J. Hydrogen Energy
6,401.
LeQue, F. L., 1979. "Qualifying aluminum and stainless alloys for OTEC heat exchangers."
Proc. 6th OTEC Conf., Washington, D.C., June, 2, 1.
Lewis, L. F., 1979. "OTEC environmental and resource assessment program," Proc. 6th
OTEC Conf., Washington, D.C., 1, 13.1.
, and C. P. Duncan, 1978. "OTEC environmental and resource assessment program,"
Proc. 5th Ocean Thermal Energy Conversion Conf., III, 1.
Liebert, B. E., J. Larsen-Basse, J. A. Berger, and L. R. Berger, 1981. "Biofouling and
corrosion studies at Keahole Point, Hawaii." Proc. 8th Ocean Energy Conf., Washing-
ton, D.C., June, 1,421.
Little, T. E., 1978. "Selection of seawater pumping systems for OTEC power plants." Proc.
5th Ocean Thermal Energy Conversion Conf., Miami Beach, Fla., Feb., 1-5, 199.
Martin, P. J., and G. O. Roberts, 1977. "An estimate of the impact of OTEC. operation on
the vertical distribution of heat in the Gulf of Mexico," Proc. 4th Annual Conf. on Ocean
Thermal Energy Conversion, New Orleans, La., March, IV-26.
Meyers, E. P., S. M. Sullivan, and J. R. Donat, 1981. "Programmatic environmental impact
statement on commercial OTEC licencing." Proc. 8th Ocean Energy Conf., Washing-
ton, D.C., 1, 453.
Miller, A. R., 1978. "A preliminary comparative study of historical sea surface temperatures
at potential OTEC sites." Proc. 5th Ocean Thermal Energy Conversion Conf., Miami
Beach, Fla., III, 214.
Molinari, R. L., 1979. "Thermal and current data for the Gulf of Mexico and South Atlantic
relative to placement of OTEC plants." Proc. 6th OTEC Conf., Washington, D.C., June,
2, 13.3-1.
Morello, A., 1978. "Bottom power cables connecting floating plants to shore."
Proc. 5th Ocean Thermal Energy Conversion Conf., Miami Beach, Fla., Feb., II-5.
Mossman, B. J., 1989. "OTEC methanol plantship proposal: A financial evaluation. "Project
in fulfillment of the requirements for the M.B.A. degree from the Wharton School of the
University of Pennsylvania. (Document available from the author.)
INTRODUCTION AND OVERVIEW 51
Nuttal, L. J., 1981. "Utilization of ocean energy." Proc. 8th Ocean Energy Conf., Washing-
ton, D.C., 1, 679.
Ocean Thermal Corp., 1984. 40-MWe OTEC power plant. Ocean Thermal Corporation,
Preliminary design engineering report, 1-4.
O'Connor, J. S., 1981. Lightweight concrete OTEC cold water pipe tests, phase II. Johns
Hopkins Univ. Applied Physics Lab., SR-80-5A.
Olsen, H. L., G. L. Dugger, W. B. Shippen, and W. H. Avery, 1973. "Solar sea power plant
conference and workshop." A. Lavi, ed., Carnegie Mellon Univ., Pittsburgh, June, p.
185.
Panchal, C. B., J. Larsen-Basse, L. R. Berger, J. A. Berger, B. J. Little, H. J. Stevens, J. B.
Darby, L. E. Genens, and D. L. Hillis, 1985. OTEC biofouling control and corrosion
protection study at the sea coast test facility 1981-83. Argonne National Lab., Report
No. OTEC-TM5.
Pandolfini, P. P., J. L. Keirsey, G. L. Dugger, and W. H. Avery, 1980. "Alclad aluminum,
folded-tube heat exchangers for OTEC." Proc. 3rd Miami International Conf. on
Alternative Energy Sources, University of Miami, Dec.
, E. J. Francis, and L. L. Perini, 1986. OTEC system. Johns Hopkins Univ. Applied
Physics Lab. Internal report.
Paulling, J. R., 1979. "Frequency-domain analysis of OTEC CWP and platform dynamics."
Proc. 6th OTEC Conf., Houston, April, 1641.
, 1959. "Frequency domain analysis of OTEC CWP and platform dynamics." Offshore
Technology Conf., Houston, OTC paper 3543.
Pieroni, C. A., R. T. Traut, D. O. Libby, and T. P. Garrity, 1979. "The development of riser
cable systems for OTEC power plants." Proc. 6th OTEC Conf., Washington, D.C., June,
1,7.2-1.
Quinby-Hunt, M. S., 1981. "Nutrient and dissolved oxygen studies at OTEC sites." Proc. 8th
Ocean Energy Conf., Washington, D.C., 1, 537.
Resales, L. A., C. Dvorak, M. M. Kwan, and M. P. Bianchi, 1978. "Materials selection for
ocean thermal energy heat exchangers." Proc. 5th Ocean Thermal Energy Conversion
Conf., Miami Beach, Fla., Feb., 4, VIII-231.
Richards, D., W. H. Avery, E. J. Francis, M. Jones, B. Heyer, A. L. Kohl, and J. K. Rosemary,
1984. "OTEC methanol-from-coal process plantship studies." Amer. Soc. Mech. Eng.,
84-WA/Sol-32, 2.
Ross, J. M., and W. A. Wood, 1981. "OTEC mooring system development: Recent
accomplishments." Proc. 8th Ocean Energy Conf., Washington, D.C., June, 85.
Sasscer, D. S., 1981. "Microbiology of aluminum and titanium ocean thermal energy
conversion (OTEC) evaporator tubes at a potential OTEC site." Proc 8th Ocean Energy
Conf., Washington, D.C., June, 1, 403.
, T. Morgan, and T. R. Tosteson, 1980. "Biofouling measurements from a moored
floating platform off Punta Tuna, Puerto Rico." Conf. Proc. 7th Ocean Energy Conf.,
Washington, D.C., June, 1, 10.3-1.
Schultz, J. A., T. C. Dalton, and R. Eaton, 1981. "The development design status of riser cable
systems for OTEC pilot plants." Proc. 8th Ocean Energy Conf., Washington, D.C.,
June, 607.
Scott, R. J., and W. W. Rogalski, Jr., 1978. "Considerations in selection of OTEC platform
size and configuration." Proc. 5th Ocean Thermal Energy Conversion Conf., Miami
Beach, Fla., Feb., 77.
Soden, J. E., R. Eaton, and J. P. Walsh, 1982. "Progress in the development and testing of
OTEC riser cables." Proc. Oceans '82 Conf., Washington, D.C., Sept., 1, 587.
52 OCEAN THERMAL ENERGY CONVERSION
established the unit of one horsepower as the power needed to raise 33,000 pounds
1 foot in 1 minute. Thus, a determination of the efficiency of steam engines in
service could be defined in terms of bushels of coal burned per horsepower
delivered; however, no basis existed for estimating what performance might be
attained by further engine improvements. The answer to this question was first
stated by the French engineer, Sadi Carnot, in a paper written in 1824. Carnot
recognized that the production of work by the thermal expansion of a fluid (or any
substance) required the transfer of heat from a source at one temperature (T 1 ) to a
heat sink at a lower temperature (T2). He showed that the efficiency of such a process
had a theoretical limit defined by the relationship:
Implicit in Eq. (2.2.1) is the recognition that heat and work are both forms of
energy and should be expressible in the same units; however, the relationship was
not established until 1843, when careful experiments by the English scientist James
Prescott Joule gave a value of 770 foot-pounds of work as being equivalent in
energy to 1 Btu of heat. More accurate measurements have established the
mechanical equivalent of heat at its present value of 778.5 ft Ib/Btu. Carnot's paper
apparently went unnoticed by engineers until 1849, when William Thompson (later
Lord Kelvin) presented to the Royal Society of England an analysis of the
implications of Carnot's paper with respect to the theoretical performance of heat
engines. Two years later Thompson and Rudolph Clausius, in Germany, indepen-
dently enunciated the law of conservation of energy, which was established as the
First Law of Thermodynamics. Carnot's equation became recognized as the Second
Law of Thermodynamics, although it had been formulated 25 years earlier than the
First Law.
Steam engine technology developed rapidly after 1850, aided by an under-
standing of the benefits of high temperature and pressure in achieving improved
efficiency, which resulted from thermodynamic analyses by Lord Kelvin, Rankine,
and others. A necessary supplement to the theoretical work was the concomitant
OTEC HISTORICAL BACKGROUND 55
Table 2-2. Pressure difference for potential working fluids (D'Arsonval, 1881)
Working Pressure difference
fluid (ram Hg)
Sulfur dioxide 137
Dimethyl ether 170
Methyl chloride 181
Ammonia 328
Hydrogen sulfide 550
Nitrous oxide 1390
Carbon dioxide 1646
used as working fluids. The table assumes a boiler temperature of 30C and a
condenser temperature of 15C.
Apparently no attempt was made to implement D'Arsonval's proposal for
power generation based on ocean temperature difference until 1926, when Georges
Claude, a French engineer and former student of D'Arsonval, embarked on a
program to demonstrate that ocean thermal power generation could be practical.
Claude believed that the cost of constructing heat exchangers of the large area
required for closed-cycle OTEC operation as envisioned by D'Arsonval would
make the process uneconomical, and that corrosion and biofouling of the heat
exchangers would pose further difficulties. He proposed to avoid those problems
by using the warm seawater itself as the working fluid in an open cycle, now known
as the Claude cycle. The basic process has been described in Section 1.2.
Claude demonstrated the feasibility of this concept in 1928 by an experiment
at Ougree-Marhaye in Belgium in which the cooling water at 30C from a steel plant
was used as a source of warm water for the boiler (evaporator) and the water of the
Meuse River at 10C as the condensing fluid. The setup incorporated a turbine of
1 m diameter mounted in a pipe between an evaporator chamber evacuated to a
pressure of 0.04 atm (the vapor pressure of water at 30C), which induced boiling
of warm water and production of steam, and a condenser vessel in which cold water
with vapor pressure of 0.02 atm was sprayed to condense the vapor. The pressure
difference between the two vessels induced rapid steam production and a high mass
flow rate that could generate significant power in the turbine despite the very low
pressure and temperature of the steam. In the test, the turbine attained a speed of
5000 rpm and generated a power output of 50 kW.
The success of this test enabled Claude to get financial backing for the next
step: demonstration of the use of cold deep water from the ocean in combination
with warm surface water to generate ocean thermal power.
For this purpose, Claude chose a site at Matanzas Bay in Cuba where the water
temperature at the surface was 25 to 28C and cold water was available at a depth
of 700 m at a distance of 1600 m from shore. The experimental plant used at Ougree
was moved to the new site. The major task was now the construction and
deployment of the long pipe that would carry the cold water from depth to the plant
on shore. The water flow needs of the 50-kW plant would have been met by use of
a 0.6-m diameter pipe and cold-water flow velocity of 2 m/s; however, Claude
OTEC HISTORICAL BACKGROUND 57
estimated that heat flow through the pipe walls during the long transit through the
1600-m pipe would warm the water almost to the surface temperature before it
arrived at the plant. Therefore, he chose to use a 2-m pipe, which would supply ten
times the required flow of cold water and increase the pumping power tenfold but
would reduce the warming to two or three degrees. Deployment of the large pipe
was beset with severe problems, partly due to the site characteristics, partly to
stormy weather, and partly to inadequate supporting facilities. Two pipes were lost
in deployment, but Claude continued and on the third try was successful in installing
a 2-km-long pipe, and operating the plant successfully. The results were in accord
with his earlier engineering estimates and demonstrated the technical feasibility of
the open-cycle concept. The cold-water pipe for this test failed in a storm after 11
days of plant operation and caused the project to be terminated; however, the
successful operation proved for the first time the technical feasibility of conversion
of ocean thermal energy to electric power.
For one of the tests in which 22 kW of power was produced, 200 liters/s of cold
water entered the condenser at 13C and left at 15C. Warm water entered at the
same rate at 27C and left at 25C. Thus the theoretical Carnot efficiency was 4.0%.
The thermal efficiency was 1.3 % (ratio of work output to heat taken from the water).
Because of the power needed to pump the water flowing through the oversized cold-
water pipe, the plant produced no net power (Claude, 1930).
In 1933, Claude installed a complete open-cycle plant, designed for ice
production off the coast of Brazil, on the 10,000-ton barge Tunisie (Claude, 1933).
The open-cycle power system was mounted in an enclosure 8 m in diameter and 25
m long, and included a turbine designed to produce 2000 kW of shaft power, of
which 1200 kW would be used for the ice machine. The ship was to be connected
by a flexible tube to a 2.5-m-diameter cold-water pipe suspended from a semi-
submersible float. Unfortunately, during deployment, heaving of the float pre-
vented successful attachment of the pipe, and in the process the pipe was lost,
forcing abandonment of the project from depletion of funds. A schematic diagram
of the Brazil plant from Marchand (1979) is shown in Fig. 2-1.
Despite his severe financial losses, Claude maintained his interest in OTEC.
In 1940, he proposed a plan to the French government for a 40-MWe plant intended
for installation at Abidjan, Ivory Coast, where a favorable site with a shallow lagoon
of solar-heated water could be used as the warm-water source. A deep canyon filled
with cold water approached to within 5 km of the coast. Claude proposed to tap the
cold water through a tunnel from shore. The project encountered problems and
proceeded slowly, but in 1948, a French government company, "Energie de Mer,"
was formed with specific objectives for development of the concept. The program
led to several significant accomplishments (Marchand, 1979):
1. An optimum evaporator design was selected after many tests.
2. A de-aerator of French commercial design was shown to be effective and of
low power consumption.
3. A low-pressure turbine of 8 m diameter was successfully constructed.
4. A complete, compact plant was designed with projected cold-water consump-
tion of 1 m3/s per MW of gross power. A 2-m-diameter cold-water pipe was
58 OCEAN THERMAL ENERGY CONVERSION
FIG. 2-1. Design of Claude OTEC plant deployed in Brazil (Marchand, 1979).
designed and tested. This was made of rigid sections of steel pipe 6.25 m long,
joined by 2.5-m-long flexible sections of rubber reinforced with steel springs.
5. A pipe 150 m long of this construction was successfully deployed at a depth of
300m.
6. A photograph of a section of the cold-water pipe of the 3.5-MWe OTEC plant
designed for the Abidjan installation is shown in Fig. 2-2.
After the development program was completed, plans were made in 1956 for
construction of a 5-MWe plant. Cost estimates showed that the plant would be
economical if a 30-year life could be attained and construction costs and financing
assumptions were valid; however, the project was abandoned when it was an-
nounced that a large dam and hydroelectric plant were to be built at Abidjan.
Studies were made in 1958 to determine whether the plant would be economi-
cally attractive for installation in Guadaloupe, but the site was found to be
unsuitable. This ended active French interest in OTEC until the 1970s.
FIG. 2-2. CWP ready for deployment at Abidjan, Morocco (courtesy, P. Marchand).
and his father described the concept at a meeting of the American Society of
Mechanical Engineers. A study of Claude's work convinced them that the open-
cycle concept was impractical because the very low pressure of the steam in the
Claude cycle required turbines too large to be feasible, and expensive and complex
equipment would be needed for removing the gases dissolved in the seawater,
which would otherwise accumulate and block the operation. Instead, the Andersons
proposed to develop the original Rankine closed-cycle concept of D'Arsonval with
improvements available in the background technology of the refrigeration and
cryogenic industries.
Features of the Andersons' design, further refined in 1966, included the use of
a floating plant with a power system employing propane as the working fluid, heat
exchangers mounted at a depth at which the water pressure would approximately
balance the pressure of the propane, and selection of construction materials and
techniques that would minimize cost. A schematic diagram of the plant is shown in
Fig. 2-3. A cost estimate indicated that their proposed system would be able to
deliver power from sites in the Caribbean at lower rates than oil, coal, or nuclear
alternatives. Although the Andersons' proposal was published in the journal of the
American Society of Mechanical Engineers, it appears to have created no visible
interest during the 1960s among energy planners, who assumed that nuclear power
and fossil fuels would meet future energy demands at minimum cost.
FIG. 2-3. Design of the Andersons' 100-MWe OTEC power plant (Anderson, 1985).
production of low-cost oil and coal for other energy needs, was replaced by
apprehension and drastic revision of energy forecasts in 1973. This resulted from
two events totally unanticipated by the energy planning community:
1. A groundswell of concern developed about the effects on human health and
quality of life of pollution of air, water, and land by automobiles, power plants,
and industry. This apprehension, augmented by public concern about the
hazards of nuclear developments, began in the late 1960s and grew to political
power by 1973.
2. Arab potentates gained control of Mideast oil production, which led to
formation of OPEC and worldwide escalation of petroleum prices, with severe
impacts on U.S. and world economies.
The first event led to vigorous public opposition to the construction of nuclear
and coal power plants; the second to rapid increases in the price of fuel for
automobiles, power plants, and industry. In this situation, strong interest arose
among scientists and engineers not affiliated with the energy establishment in the
development of pollution-free, safe, and inexhaustible sources of energy that could
replace the conventional sources now publicly unacceptable. Attention was fo-
cused on the direct use of solar energy to produce electric power and heat, and on
OTEC HISTORICAL BACKGROUND 61
energy sources indirectly dependent on solar energy such as winds, waves, tides,
heat stored in the surface waters of the tropical oceans, and wood, kelp, and other
forms of so-called "biomass" that could be processed to produce fuels.
The time was appropriate for a resurgence of interest in ocean thermal energy.
A major contribution to this interest was made in an article in Physics Today written
by the distinguished physicist, Clarence Zener (Zener, 1973). He called attention
to the Andersons' design of an ocean thermal plant and its estimated costs, and
stated that the rising costs of nuclear plants would make them more expensive than
ocean thermal plants. After a careful review of positive and negative factors for
ocean thermal plants versus nuclear and coal plants, Zener concluded that ocean
thermal plants would be superior from both cost and environmental standpoints.
Zener's paper inspired interest by many research organizations in the United
States and led the U.S. National Science Foundation (NSF) to expand its support of
study programs on ocean thermal energy. (A small contract on the subject had been
awarded to the University of Massachusetts in 1972.) Under NSF sponsorship, the
first OTEC workshop was held at Carnegie-Mellon University (CMU) in June
1973 and attracted approximately forty attendants, representing NSF, CMU, the
University of Massachusetts, The Johns Hopkins University Applied Physics
Laboratory (JHU/APL), and representatives of government and industry.
Interest in OTEC, along with other solar-based energy sources, grew rapidly
with strong support from the U.S. Congress. A sense of urgency was provided by
the oil embargo of 1974. Funds for new energy alternatives were appropriated in
response to public demands for the development of energy options that would be
safe, environmentally acceptable, and nonpolluting. From this impetus, the Energy
Research and Development Administration (ERDA) was established in January
1975 with the mission to evaluate all potential energy options for the U.S. future and
to support development of the most promising forms. To provide foxes to guard the
fledgling products being hatched, personnel for the new agency were drawn from
the existing agencies concerned with energy research and development, in rough
proportion to their budgets: namely, 90% from the Atomic Energy Commission
(AEC), 10% from the Bureau of Mines, and 0.1% from the NSF, which acquired
responsibility for all solar energy programs.
After its preliminary review, ERDA endorsed the development of renewable
energy options but contended in public statements that OTEC, along with other
solar energy options, could not be expected to contribute significantly to U.S.
energy needs before the year 2000 and that emphasis in ERDA programs should be
placed on development of nuclear and coal options. It was therefore stated that the
funds supplied by Congress for OTEC should be used to support research programs
on ocean energy subsystems and components that would provide a technical base
for later OTEC development, if and when needed. This position accurately
represented the opinions of the public utilities, the nuclear power industry, the oil
companies, and the coal companies. It did not reflect the views of the scientists and
engineers who had studied energy options in some depth, nor of the general public
and their representatives in Congress. A situation developed in which the Congress
every year appropriated more money for ocean energy development than ERDA
62 OCEAN THERMAL ENERGY CONVERSION
[and its successor in 1977, the Department of Energy (DOE)] requested, and the
funds were then distributed by DOE to support, for the most part, unfocused efforts
on energy projects. In the OTEC program, the funds were used initially to establish
a broad program to investigate the ocean sciences, engineering disciplines, and
components basic to OTEC development, including two small contracts to consider
potential OTEC system designs.
Reports on these projects were issued in 1975, with the conclusion that OTEC
systems were feasible and projected costs were attractive. (The goals and accom-
plishments of the research and development programs are discussed in Section 1.2
of this volume.) As the work progressed, it became apparent that the technology was
ready for the design and construction of pilot systems that would provide valid
engineering data on which to base commercial development; however, reorienta-
tion of the work toward pilot plant construction was opposed by the DOE
management. Instead, a major program was initiated to provide a large-scale test of
one component of an OTEC system, the heat exchanger, and lesser efforts were
directed to further studies of other components and subsystems.
The OTEC program of ERDA inherited a research orientation from the NSF
and was devised with the long-range interests of the electric power industry in mind.
An alternative base for OTEC support existed in the research and development
program of the Maritime Administration (MARAD) of the U.S. Department of
Commerce. MARAD's research and development goals were directed to enhance-
ment of the commercial success of the U.S. Merchant Marine and were focused on
efforts that would provide commercially attractive opportunities for new ship
construction and products that would improve the U.S. balance of trade. The
MARAD evaluation of OTEC, based on their strong background in marine
engineering and the orientation of the division head, Marvin Pitkin, toward solving
problems rather than studying problems, convinced them that OTEC should be
oriented toward system development and gave MARAD a positive interest in
supporting a research and development program that could lead to early commer-
cialization of the concept.
With this objective, MARAD awarded a contract to JHU/APL in 1974 to
investigate the "Maritime and Construction Aspects of Ocean Thermal Energy
Conversion (OTEC) Plantships." The program considered site selection, plantship
design, on-board production of ammonia and other OTEC products, maritime
impacts, and legal and political implications. The final report on the program,
issued at the conclusion of the contract (Avery et al., 1976), affirmed the feasibility
of OTEC and stated that OTEC plantships should be capable of profitable produc-
tion of ammonia and other products. With government support during develop-
ment, it was projected that ammonia plantships could be in commercial operation
within 10 years.
The positive conclusions of the report led MARAD to support a follow-on
program to explore the investment requirements for commercial development of
OTEC plants. A favorable report on this study was issued in 1977.
In April 1977, the results of these studies led JHU/APL to propose to MARAD
the preliminary engineering design of a 20-MWc OTEC pilot plant that, after
OTEC HISTORICAL BACKGROUND 63
The response to the PON was enthusiastic. Consortia were formed by industry
that included major representation from the shipbuilding, power plant, and refrig-
eration industries, pump manufacturers and others, who contributed many man-
months of effort in formulating responses. Eight proposals were received represent-
ing three positioning options (two land-based, five moored, and one grazing); eight
plant concepts; proposed sites in Puerto Rico, Hawaii, the Gulf of Mexico near
Tampa, the Marianas Islands, and the Pacific Ocean south of Hawaii for the grazing
plant; and several product and management options. However, with the change of
Administration in 1980, the ground rules were changed. Only two conceptual-
design contracts were awarded, both for shelf-mounted designs to deliver electrical
power to the island of Oahu, Hawaii. The remaining $4.5 million of the appropria-
tion was deferred to be used for a single second-phase contract award. This action
of DOE was regarded by the OTEC community as a gross breach of faith, and dealt
a body blow to major industrial interest in OTEC commercialization.
Two conceptual design contracts were awarded, one to General Electric
(Lessard, 1982) and one to Ocean Thermal Corporation (1982). On the conclusion
of these contracts, one contract was awarded by DOE to Ocean Thermal Corpora-
tion for the preliminary design phase, after which DOE terminated support for
OTEC system development and announced that further development would have
to be done exclusively with private funding. The preliminary design contract was
completed in November 1984.
With installation of the new Administration in 1980, perceptions of the need
for the alternative energy sources diminished. Funding was progressively reduced
and, in 1984, the DOE OTEC system development program was terminated after
the preliminary design of a land-based 40-MWe OTEC plant for siting at Kahe Point
on the Island of Oahu, Hawaii, was completed. Plans were announced by Ocean
Thermal Corporation for beginning construction of the 40-MWe plant in late 1986
with private financing but were put on hold when oil prices dropped precipitously
in 1985.
No funds were requested for OTEC by DOE in fiscal years 1982, 1983, and
1984, but Congress appropriated modest funds specifically identified to support the
research programs directed by the Solar Energy Research Institute and Argonne
National Laboratory. In 1985, DOE announced a reorientation of its thinking about
OTEC and requested funding for support of limited research efforts on open-cycle
OTEC. The DOE interest was stimulated by a Japanese offer to support work in
Hawaii through the Pacific International Center for High Technology Research
(PICTR). Minimal funding was requested through! fiscal year 1989 for study of
CWPs for small, shore-based plants and for research on power plant subsystems,
but no funding was requested for 1990 and 1991.
Thus, Japanese interest in OTEC preceded the revival of interest in France and the
United States. Preliminary results of the investigation, including a system concept,
were presented by Kamogawa (1972) to the fifth general meeting of the Pacific
Basin Economic Council in a paper entitled "Equatorial Industrial Marine Com-
plex." The concept involved OTEC power generation and use of the nutrient-rich
cold water for mariculture.
Interest in OTEC continued to develop and led to the inclusion of OTEC in a
development program on new energy technologies called the "Sunshine Project,"
which was established in 1974 (Kajikawa, 1982). Concurrently, experimental
research was begun at the Electrotechnical Laboratory of AIST in Tokyo and at the
Science and Engineering Faculty of Saga University in Saga. Design studies of
land-based OTEC power plants were also started in this period by the Tokyo
Electric Power Service Co. (TEPSO).
The objectives and program accomplishments during the period 1974-1979
have been summarized by Kamogawa (1980) as follows: "The objectives of the
OTEC feasibility study ... were the evolution of technical and economic factors of
the concept as a whole. As a first step, design work was conducted in 1974 on a 1.5-
MW land-based experimental OTEC power plant. In the second year, 1975, a
conceptual design was prepared for an ocean-based demonstration OTEC power
plant rated at 100 MW and sited at a benign tropical location. The design was based
on the current state of technology with minor improvements, particularly in the heat
exchangers. In the third year, 1976, an improved conceptual design of a 100-MW
power plant, to be located in the sea near Japan, was made. This later design was
based on advanced technology. The results of the study were reported. In the
following two years (1977 and 1978), additional work on the previous year's
designs was carried out. Emphasis was placed especially on the optimum design of
100-MW plants, the platform structure and station-keeping at the representative
sites, structure model experiments in a wave flume, and improvements in the heat
exchangers."
The studies of 100-MW OTEC plants included estimates of total system
investments and operating costs for floating and semi-submerged concepts, from
which delivered power costs could be estimated. The results indicated that con-
struction costs would be in the range of $2000-3000/kW, and busbar power cost
would be in the neighborhood of 60 mills/kW h (1977 dollars) (Homma and
Kamogawa, 1979). This estimate led to expectations that OTEC power could
become competitive with other sources if commercial operation was established.
Accordingly, a three-phase development plan was outlined that would involve
major subsystem development and component testing and evaluation from 1978 to
1983, development of a 10- to 25-MW at-sea engineering test facility along with
additional major component development during the period 1983-1989, and
beginning of commercial construction in 1990.
Specific goals established for the first-phase program included:
1. Development of economically viable heat exchanger designs by laboratory
tests, small-scale at-sea tests, and system simulation tests;
68 OCEAN THERMAL ENERGY CONVERSION
2. Development of the technology needed for the design of cold-water pipes and
mooring systems through analysis, simulation, and small-scale model tests in
water tunnels and at sea;
3. Investigation of oceanographic conditions and the thermal resources for
candidate sites at sea; and
4. Development of the design methods to determine the optimum OTEC system
from an economic standpoint for the proposed sites, recognizing the tempera-
ture distributions and seasonal variations in the thermal resource.
The first-phase program led to a number of significant accomplishments:
1. An on-shore, 100-kW closed-cycle OTEC test facility was installed on the
seashore of the island of Nauru, in the equatorial Pacific Ocean at latitude 0.5S
and longitude 167E. The plant employed a polyethylene CWP of 70 cm inner
diameter and 1250 m length that drew cold water from 700 m depth. This gave
a Tof 24C. Titanium shell-and-tube heat exchangers were installed. A thin
copper coating on the water side of the tubes in the evaporator and fluting of
the working-fluid side in the vertical condensers were used to enhance heat
transfer. The plant operated successfully for a series of experiments conducted
over a period of about 1 year that confirmed predicted performance. A
maximum power output of 120 kW and net power of 31.5 kW were demon-
strated. Testing was concluded in September 1982 (Ito and Seya, 1985).
2. A Japanese "Mini-OTEC" was deployed successfully in October 1979 at a site
off the coast of Shimane in the Japan Sea, where the temperature was 23.1C
at the surface and 0.5C at a depth of 230 m (Uehara et al., 1980). Details of the
test are given in Section 6.3.4.
3. A research and development program based on a 50-kW experimental facility
was established at Saga University to investigate the performance of plate-type
heat exchangers and other power system components, and to provide informa-
tion for system optimization of OTEC power plants. The data obtained were
used for analysis of an optimum power cycle for a 100-MWe OTEC power
plant (Uehara, 1982).
4. Construction of a 50-kW closed-cycle OTEC plant was started by the Kyushu
Electric Power Co. in Tokunoshima, on the southwestern coast of the island of
Kyushu. The design employs plate-type heat exchangers and ammonia work-
ing fluid.
5. Conceptual designs of 1-MWe barge- and spar-type OTEC pilot plants were
prepared. An OTEC simulator was developed to measure the sensitivity of the
system performance to variations in the input conditions, for example, effects
of heave, pitch, and roll on pump operations. Follow-up led to the preliminary
design of a 1-MWe barge-type test facility for a site off Kumejima, near
Okinawa. The steel barge (100m X 30m X l7m, draft 12 m) would be attached
to a mooring buoy that would support a steel CWP 1.8m inner diameter X 700
m long (Kajikawa et al., 1978).
6. Experimental programs were initiated to support the design work with data on
advanced materials, design methods, and procedures.
OTEC HISTORICAL BACKGROUND 69
and when subjected to current forces after installation. It was specified that
the pipe would be 3 m in diameter and 3 km long.
c. Financial analyses and economic projections were made to evaluate the
potential role of OTEC as a future energy source. Considerations of future
costs of petroleum and expected technical development of OTEC led to a
conclusion that 50-MWe OTEC plants could compete in the midterm with
diesel-powered generation of electric power. Benefits of fresh-water pro-
duction were included.
The results of these studies led to a provisional decision to proceed with the
design of a 5-MWe land-based OTEC pilot plant that could be in operation in 1989.
REFERENCES
Anderson, J. H., 1985. "Ocean thermal power: the coming energy revolution." Solar and
Wind Technology 2, 25.
Avery, W. H., R. W. Blevins, G. L. Dugger, and E. J. Francis, 1976. Maritime and
construction aspects ofOTECplantships. Johns Hopkins Univ. Applied Physics Lab.,
SR76-1B.
Callendar, H. L., and D. H. Andrews, 1958. "Heat." Encyclopedia Britannica 11, 315.
Castellano, C. C., 1981. "Overall OTEC-1 status and accomplishments." Proc. 8th Ocean
Energy Conf., Washington, D.C., 2, 971.
Claude, G., 1930. "Power from the tropical seas." Mechanical Engineering, 52, 1039.
, 1933. "Sur une usine flottante Claude-Boucherot." Academic des Sciences (France),
May.
D'Arsonval, A., 1881. "Utilisation de forces naturelles." Revue Scientifique, 2, 370.
Fenn, J. B., 1982. Engines, energy and entropy. New York: W. H. Freeman.
Forbes, R. J., 1958. in A history of technology. Vol. 4, p. 164. New York: Oxford University
Press.
George, J. F. , D. Richards, and L. L. Perini, 1979. A baseline design of an OTEC pilot
plantship. Johns Hopkins Univ. Applied Physics Lab., SR 78-3A.
Homma, T., and H. Kamogawa, 1979. "An overview of Japanese OTEC development."
Proc. 6th OTEC Conf., Washington, D.C., June 1, 3.3.
Ito, F., and Y. Seya, 1985. "Operation experiences of 100-kW OTEC and its subsequent
research." Marine Technology Society, Ocean Energy Workshop. Washington, D. C.,
35.
Kajikawa, T., T. Agawa, H. Takayawa, K. Nishiyama, M. Amano, and T. Homma, 1978.
"Study on OTEC power cycle characteristics with ETL-OTEC-II experimental facil-
ity." Proc. 5th Ocean Thermal Energy Conversion Conf. 2, V-164.
, 1982. "Status of R&D activities in Sunshine project." Marine Technology Soc., Ocean
Energy Workshop. Washington, D. C., 35.
Kamogawa, H., 1972. "Equatorial marine-industrial complex. A report for the Natural
Resources Development Committee." Proc. 2nd International Ocean Development
Conf., Tokyo, Oct. 1.
, 1980. "OTEC research in Japan." in Energy. Pergamon Press Ltd.
Lessard, D., 1982. "Conceptual design of a tower-mounted, 40-MWe pilot plant for Oahu,
Hawaii." Proc. 5th Miami Conf. on Energy Sources, Miami Beach, Dec.
Liao, T., J. G. Giannotti, P. R. Van Mater, Jr., and R. A. Lindman, 1986. "Feasibility and
concept design studies for OTEC plants along the east coast of Taiwan, Republic of
China." Proc. International Offshore Mechanics and Arctic Engineering Symposium,
2,618.
Marchand, P., 1979. "The French OTEC program." Proc. 6th OTEC Conf., Washington,
D.C., June, 1,790631, 3.2-1.
, 1986, "Ocean renewable energy resources: A chance for the future?" Conference SUT
"Exclusive Economic Zones," London, 1.
Ocean Thermal Corp., 1982. Ocean thermal energy conversion (OTEC) pilot plant concep-
tual design study. Ocean Thermal Corp., internal report.
Paoloni, E. C., 1982. "Conceptual design of a 40-MWe OTEC pilot plant on an artificial
island off Oahu, Hawaii: OTEC power for Hawaii." Proc. 5th Miami Conf. on Alt.
Energy Sources, Miami Beach, Dec., 3.
72 OCEAN THERMAL ENERGY CONVERSION
Uehara, H., 1982. "Research and development on ocean thermal energy conversion in
Japan." Proc. American Institute of Chemical Engineers 17th IECEC Conf., Washing-
ton, D. C., June, 4, 1454.
, 1990. "Ocean energy." Japan Society for Mechanical Engineers 14.4, 1.
, S. Nagasaki, and H. Yokohama, 1980. "Deployment of cold water pipe in the Japan
Sea." Proc. 7th Ocean Energy Conf., Washington, D. C., June, II, 14.4.
, H. Kusuda, M. Monde, T. Nakaoka, T. Yamashita, and N. Maeda, 1981. "The test of
OTEC plant in Imari Bay." Proc. 8th Ocean Energy Conf., Washington, D. C., June, 2,
803.
Zener, C., 1973. "Solar sea power." Physics Today, January, 48.
3
OTEC SYSTEM CONCEPTS
Failure to define the system need with sufficient clarity is a root cause of
most system development difficulties. It must not be assumed that the
government or other sponsor's statement of a requirement is adequate. The
need must be stated in systems engineering terms, including the criteria for
determining the suitability of the system to be developed and the date when
the new system must be operational.
2. A listing of alternative system concepts for meeting the need is prepared. For
alternative energy sources, this includes fuel synthesis from coal, nuclear
power, hydropower, photovoltaic generation of electricity, solar thermal heat
production, energy from biomass, OTEC, wind power, and other possibilities.
3. A first-order evaluation is made of the concepts identified in (2) for technical
feasibility, potential contribution, environmental impacts, manufacturing ca-
pability, operational practicality, rough cost, and estimated development time.
The purpose of this evaluation is to select three or four options of major promise
that fulfill the operational need for in-depth consideration. A common diffi-
culty in this task is a desire to avoid choosing any option until it can be proved
that the "best" concept has been identified, even though several options would
apparently meet the system requirements; however, selection of the favored
concepts should not be based on a rating system that incorporates inadequate
data. Engineering judgment must not be replaced by decisions based on a
matrix of faulty numbers.
4. An engineering study (conceptual design) is made of each of the attractive
concepts to document component performance and cost where available, to
identify needs for additional information, and to suggest research and devel-
opment programs that would provide information required to assure technical
feasibility and minimum cost for the concepts.
5. Development programs are outlined for one or more of the favored concepts.
In each program, the research and development needs are identified in separate
subprograms, each of which is evaluated according to the rationale outlined.
A multiphase development plan is then prepared that outlines a work schedule
for each subprogram, showing estimated completion dates and identifying
efforts and funding critical to completion of the program on the desired time
scale.
6. If the required funding is available and time scales are suitable, development
programs are established that proceed through the phases of preliminary
design, engineering design, construction, deployment, and operational testing,
with review at the end of each phase. The final phase is commercial construc-
tion and enduring operation of the system.
The requirement for a new system to be designed to achieve a minimum cost
deserves special comment. Since World War II, research and development of major
new systems have been funded by government requirements for advanced technol-
ogy to meet perceived threats to national security or public welfare. The goal of such
efforts has been to move the science and engineering underlying the new concept
beyond existing frontiers. Advanced performance became the criterion for excel-
OTEC SYSTEM CONCEPTS 75
lence. Cost entered the picture as the final step in decisions among candidate
systems, which were then required to adhere to pre-established design specifica-
tions. Such programs were regarded as high risk, were exciting to work on, and
attracted the most competent program participants. Conversely, programs with a
goal to reduce cost while maintaining established performance came to be regarded
as dull, suitable for second-level personnel, and unimportant.
This attitude must be changed in planning renewable energy developments,
which must be of reasonable initial cost if they are to attract industrial support as
opposed to governmental support and become commercially successful.
Costs of the first production version of systems requiring development of new
technology are usually underestimated, often by large amounts. A common cause
is optimism about the expected performance of undeveloped components or
subsystems, and failure to consider off-design features. The largest errors result
from several faulty assumptions or procedures in the design process:
1. Bottom-up rather than top-down systems design. This procedure, favored by
government program managers, leads to development and optimization of
system components by different contractors as isolated items. In final assem-
bly, it is found that components or performance is incompatible and that system
redesign is required. This leads to extended schedules and large cost overruns.
It is analogous to awarding individual contracts to makers of a jigsaw puzzle,
one contract for manufacture of the red pieces, another for the blue pieces, and
so on, with a final contract to a systems contractor to assemble the puzzle using
the delivered pieces.
2. Failure to involve industrial contractors who would be potential producers and
installers of the system in the initial phases of the systems design. Many
systems at the end of development are faced with major redesign because the
components or systems are not compatible with manufacturing facilities or
procedures for cost-effective production.
3. Failure to identify design for minimum cost as a primary development goal.
The desire of engineers to design for performance that exceeds the state of the
art, with cost as a secondary objective, can introduce unforeseen problems and
delays, with serious cost overruns.
4. Lack of a well-defined development, test, and production plan with appropri-
ate, scheduled funding subject to timely reviews of progress.
Much effort has been given to the search for alternatives to the use of
petroleum fuels. Coal may be substituted for some fraction of the liquid or gaseous
fuels used by industry to provide process heat, but coal is impractical as an energy
source for transportation or general purposes. Thus, it may be estimated that
approximately 40% of the world's energy needs must be supplied by liquid or
gaseous fuels, if the present forms of transportation and nonindustrial energy uses
are to be continued.
Several alternative solutions to the problem of petroleum fuel depletion have
been proposed:
1. Improvement in the efficiency of liquid fuel use. This is the most attractive
immediate approach because most of the equipment and devices that use liquid
or gaseous fuel that were designed before 1980 sacrificed efficiency for lower
cost or did not consider efficiency important in the design. Thus, large gains
can be possible with small changes in design. Implementation of this approach
in the United States since the mid-1970s has significantly reduced fuel use with
minor impacts on life styles or equipment costs. Major gains in efficiency
would be possible if practical methods were developed for replacing internal
combustion engines with electric motors powered by fuel cells (Flavin, 1992);
however, it is clear that with continued increases in world demands for energy,
particularly in the developing countries, efficiency improvements will not be
sufficient.
2. Production of synthetic conventional fuels from coal in land-based plants. This
approach has been shown to be technologically feasible but was not commer-
cially attractive with projected costs of crude oil at $28 per barrel and natural
gas at $5 per million Btu. The proposed equipment and processes require the
use of approximately two atoms of carbon for each atom incorporated in the
liquid fuel. Thus, the greenhouse problem would be doubled by using coal with
these processes to replace petroleum fuel. The environmental concerns would
add to the cost.
3. Substitution of liquid-fuel energy by electrical energy produced in nuclear or
coal-fired power plants. Electrical heat can replace oil or gas used for heating,
but at high cost. Heat from electrical energy at $0.06/kW h is equivalent in cost
to heat from oil at $74/bbl. Higher efficiency can compensate to some extent.
Electric energy can be used to charge storage batteries, which can provide
motive power for vehicles; however, great reductions must be made in battery
weights and volumes before battery-powered vehicles could be practical for
ordinary transportation purposes.
4. Production of fuels from biomass, such as wood, organic waste materials, kelp,
or agricultural products. This approach is technically feasible and has been
successfully used for production of ethyl alcohol for motor vehicle fuel,
particularly in Brazil (Renner, 1989). Large government subsidies have
encouraged development of an infant industry in the United States. With this
option, an equilibrium energy cycle could possibly be established in which the
CO2 produced by combustion of biomass-produced fuels would be consumed
OTEC SYSTEM CONCEPTS 77
FIG. 3-1. Sites surveyed for potential OTEC plantship operation (Wolff et al., 1979).
OTEC SYSTEM CONCEPTS 79
OTEC preliminary design purposes. These data have been used to estimate, by time
of year and geographical location, the stresses that would be imposed on planned
structures and to provide a basis for appropriate structural design. (The design
requirements are discussed in Chapter 4.)
The most severe stresses are associated with the massive waves produced by
hurricanes, which have reached record heights of nearly 33 m (100 ft) at latitudes
above 30. Hurricanes do not occur at latitudes in the 10 zone centered on the
equator; so the structural requirements are significantly less for ships and installa-
tions confined to that region.
Methods for predicting hurricane frequencies and intensities were developed
and have been refined since 1959 by Bretschneider. His formulas are now accepted
as the standard for design calculations (Bretschneider, 1975,1977,1978,1979). For
example, his formulas predict for the most severe storm in 100 years, maximum
wave heights of 16 m for the tropical mid-Atlantic Ocean and 27 m for the southern
coast of Puerto Rico (George et al., 1979). The damage potential to structures from
waves of this magnitude with their associated currents has major significance for
the design of floating OTEC platforms as well as shore-based installations.
Stresses imposed by winds on exposed structures must be considered in OTEC
design but are small compared to the loads induced by wave action, and play a
secondary role in OTEC systems engineering. Fatigue problems in normal opera-
tion are also expected to be of secondary importance for overall system design, and
will be less severe in the more benign environment near the equator. There may be
a need in some components to design around possible resonance effects associated
with differences in average wave frequency at potential sites.
3.3.1.3 Conclusions Regarding the OTEC Resource
It is clear from the preceding discussion that the ocean energy resource that could
be used by grazing OTEC plantships is ample to provide an alternative to U.S.
dependence on petroleum fuels.
The major resource implications for OTEC systems engineering are that
power output will be much higher for plants operating with the high T available
near the equator, and that structural requirements and costs will be appreciably less
for installations sited in the less rigorous environment at low latitudes. The large
waves and currents that develop in shallow water during storms place special
structural demands on near-shore and shore installations. Thus, much lower cost per
kilowatt of on-board power can be expected for plants designed for grazing
operation at ocean sites near the equator. This conclusion is of fundamental
importance in the selection of OTEC system alternatives.
2. The open-cycle (OC) process described by Claude and Boucherot (1928) and
Claude (1930) in which low-pressure water vapor, generated by seawater
boiling under reduced pressure, is the working fluid.
Other alternatives for OTEC include the use of water vapor produced by vigorous
surface evaporation at low pressure to lift droplets of liquid spray or foam to an
appreciable height where they may be collected. Power may then be produced by
directing the water through a hydraulic turbine as it flows back to sea level. The
mist-lift system of Ridgway (1977) and the foam-lift design of Zener and Fetkovitch
(1975) employ this procedure. Power may also be produced through the use of hot
and cold ocean water sources for thermoelectric generation (Kajikawa, 1982). The
concepts are discussed in detail in Chapters 4 and 5.
Estimates of the performance, size, and cost requirements of OTEC OC power
systems based on component testing at reduced scale are available. Less detailed
estimates indicate that the other concepts mentioned previously would have similar
net efficiencies and would have similar cold- and warm-water mass flows per
kilowatt of net power delivered; however, there will be major differences in the
systems engineering requirements for power system components and for the
platform, both in size and configuration, which must be considered in evaluating the
overall merits and costs for OTEC applications. Discussion of the systems engi-
neering implications of these factors is restricted here to the first two concepts since
complete systems designs have not been developed for the last three.
3.3.2.1 Differences between Closed-Cycle and Open-Cycle Systems
A fundamental, major difference between the CC and OC systems is in the sizes of
the ducts and turbines, which are roughly proportional to the specific volume of the
working fluid. In the closed cycle employing ammonia, the inlet pressure to the
turbine is approximately 860 kPa (125 psi). In the Claude open cycle, the water
vapor pressure is 3.1 kPa (0.45 psi at 25C). Allowing for differences in thermody-
namic properties, flow velocities, and design variables, the duct area must be over
100 times as large in the latter case. A duct and turbine about 15 m in diameter (50
ft) would be required for the OC system to accommodate the water vapor flow of
a 10-MWe OTEC plant module. This can be compared to the 1.4-m diameter
required for the ammonia flow of the CC system (George and Richards, 1980). A
conceptual design study of a 100-MWe (net) open-cycle plant by Westinghouse
(Coleman and Rogers, 1981) called for a turbine tip diameter of 44 m (144 ft), a
power plant diameter of 113 m (373 ft), and a height of 98 m (320 ft).
A second difference between open- and closed-cycle OTEC systems is in the
elimination in the OC system of the very large areas of metal surface required for
heat transfer in the CC system. In a nominal closed-cycle power plant, 6.2 m2 (67
ft2) heat exchanger surface area will be required per kilowatt of net power delivered,
or approximately 60,000 square meters for a 10-MWe power output. Elimination
of this metal surface and the pressure vessels and pumps of the ammonia system
results in a major reduction in the complexity of the heat transfer equipment
compared to the OC direct contact exchangers. The need for biofouling control
equipment is also eliminated. Since heat transfer coefficients are higher for the OC
82 OCEAN THERMAL ENERGY CONVERSION
system, the water flow needs may also be lower. A full discussion of OC systems
is presented in Chapter 5.
3.3.2.2 Conclusions Regarding Power Plant Type
An assessment of the relative merits of the CC versus the OC concept for total
system engineering performance and costs cannot be made without further research
and development on the OC system; however, the large volume requirements of the
OC plant raise serious questions about its suitability for grazing OTEC plantships.
The choice will involve evaluation of the dependence of power plant cost on plant
size, implications of the OC size and performance on total platform size and system
cost, and possible advantages in fresh-water production as well as electric power.
It must also be recognized that OC may have special advantages for small tropical
island installations, which could offer an attractive way to begin commercialization
of OTEC technology.
risk, and cost. Generic studies were supported of OTEC configurations based on
semi-submersible, spar, sphere, cylinder (or disk), and submerged platforms, as
well as barge-ship types. All incorporated suspended CWPs (Waid, 1978; Scott and
Rogalski, 1978; Basaret al., 1978). Schematic designs illustrating the concepts are
shown in Fig. 1-11. Studies of shore- or shelf-mounted plants were conducted by
Brewer (1979) and Brewer et al. (1979).
Structural requirements and the apparent relative costs of OTEC power plants
designed for off-shore power generation at levels ranging from 50 to 500 MWe were
evaluated for sites in Hawaii; Key West, Florida; Puerto Rico; and south of New
Orleans in the Gulf of Mexico. A DOE requirement was imposed that stated all
options of a given power output should use the same power plant, and that a single
CWP sized for an internal water flow velocity of 6 ft/s would be used. All
investigations selected a 25-MWe power module as a basic unit which could be
repeated for higher power levels. A figure of merit was developed for each design
that included weighting factors for technical feasibility, the state of the technology
required for construction of the design, the estimated risk, and cost. The Waid study
found the types designated as circular barge, submersible, spar with detached
modules, and ship to be essentially equivalent for off-shore OTEC power pro-
duction. Waid noted that if the grazing operation had been included, only the ship
would have qualified. The Scott-Rogalski study gave the highest rating to the ship-
barge. Spar and semi-submersible ranked second for power ranges from 100 to 350
MWe, while sphere and spar had second ranking for powers in the range 350 to 500
MWe. As in the Waid study, only the ship-barge options would have qualified for
grazing operation. Basar et al. (1978) considered a wide range of surface and
submerged options in which the CWP was either pinned to the platform or
separately supported from a buoy. They concluded that surface-supported configu-
rations should be eliminated because stresses in the pinned CWP would require
unacceptably high wall thickness and weights. Submerged designs could alleviate
this problem. Their study gave highest ranking to a novel tubular truss designed by
Rosenblatt & Sons, Inc. The assumption that the CWP would be pinned to the
platform made the ranking invalid for configurations using a flexible joint. The
work of Waid and of Scott and Rogalski showed that CWPs supported by a flexible
joint at the platform would be feasible at diameters of at least 10m and could be
made with either concrete or fiber-reinforced plastic. (The subject is discussed in
detail in Chapter 4.)
3.3.4.3 Conclusions Regarding Platform-CWP Design Options
The design investigations indicate that a ship-barge configuration with a flexible
CWP suspended from the platform by a flexible joint will be optimum for the
grazing mode of OTEC operation. This configuration will also be a candidate for
moored operation; however, problems of power transmission from a bobbing ship-
barge suggest that other alternatives could have overall system advantages for this
role. A DOE decision in 1980 to concentrate OTEC research and development
effort on shore-mounted or shelf-mounted systems has left unresolved the question
of optimum design for moored or dynamically positioned OTEC power plants.
OTEC SYSTEM CONCEPTS 87
REFERENCES
Anderson, J. H., and J. H. Anderson, Jr., 1966. "Sea solar power." Mechanical Engineering,
41.
Avery, W. H., D. Richards, and G. L. Dugger, 1985. "Hydrogen generation by OTEC
electrolysis, and economical energy transfer to world markets via ammonia and
methanol." Int. J. of Hydrogen Energy, 10, 727.
Basar, N. S., J. C. Daidola, and N. M. Maniar, 1978. "OTEC ocean systems evaluation."
Proc. 5th Ocean Thermal Energy Conversion Conf., Miami Beach, Fla., Feb., 2, IV-15.
Bretschneider, C. L., 1975. "Operational sea state and design wave criteria, a generalized
study for OTEC." Proc. 3rd Workshop Ocean Thermal Energy Conversion, OTEC,
Houston, May, 87.
, 1977, "Operational sea state and design wave criteria: State-of-the-art of available data
for US A coasts equatorial latitudes."Proc. 4th Annual Conf. on Ocean Thermal Energy
Conversion, New Orleans, Mar., 4, 61.
, 1978. "Operational sea state and design wave criteria for potential OTEC sites." Proc.
5th Ocean Thermal Energy Conversion Conf., Sept., 2, IV-178.
, 1979. "Appendix A 100-year design hurricane wave criteria for potential OTEC sites."
Proc. 6th OTEC Conf., Washington, D.C., June, 1, 6.10-7.
Brewer, J. H., 1979. "Land-based OTEC plants-cold water pipe concepts." Proc. 6th OTEC
Conf., 1,5.10-1.
, J. Minor, and R. Jacobs, 1979. Feasibility design study. Land-based OTEC plants. U.S.
Department of Energy, COO-4931-0.
Churgin, J., and H. Iredale, 1979. "OTEC data base and data products: NOAA." Proc. 6th
OTEC Conf., Washington, D.C., June, 1, 13.4-1.
Claude, G., 1930. "Power from the tropical seas." Mechanical Engineering, 52, 1039.
, and P. Boucherot, 1928. "Conferences faites grand amphitheatre de la Sorbonne."
Conf. on Ocean Energy, Feb., 3.
Coleman, W. H., and J. D. Rogers, 1981. "Design and development of an open-cycle OTEC
turbine with particular emphasis on mechanical design aspects of rotor blades." Proc.
8th Ocean Energy Conf., Washington, D.C., 2, 277.
Davidson, Jr., H., and T. E. Little, 1978. "OTEC platform station keeping analysis." Proc.
5th Ocean Thermal Energy Conversion Conf. 2,1V-237.
Flavin, C., 1992. "Building a bridge to sustainable energy." in State of the World 1992,
WorldWatch Inst., p. 27.
George, J. E., D. Richards, and L. L. Perini, 1979. A baseline design of an OTEC pilot
plantship. Johns Hopkins University Applied Physics Laboratory, SR-78-3A.
, and D. Richards, 1980. Baseline designs of moored and grazing 40-MW OTEC pilot
plants. Johns Hopkins University Applied Physics Laboratory, SR-80-A.
OTEC SYSTEM CONCEPTS 89
Giannotti, J. G., K. A. Stambaugh, and W. K. Jawish III, 1981. "OTEC cold water pipe
hydrodynamic loading and structural response: At-sea measurements, model experi-
ments and analytical simulations." Proc. Int. Symp. on Hydrodynamics in Ocean
Engineering, Norwegian Inst. of Technology, 963.
Goldman, G. G., and D. Pesante, 1979. "Preliminary results of a program to study OTEC
oceanic environmental parameters at Punta Tuna, PR." Proc. 6th OTEC Conf, Wash-
ington, D.C., June, 1,13.9.
Hill, F. K., 1979. Satellite tropical ocean surveys of SST. Johns Hopkins Univ. Applied
Physics Lab., FKH 79-4.
, and G. L. Dugger, 1979. "Use of satellite-derived sea surface temperatures for cruising
OTEC plants." Proc, 6th OTEC Conf., 2, 13.8.
Kajikawa, T., 1982. "Status of R&D activities in Sunshine project." Proc. Marine Technol-
ogy Soc. Ocean Energy Workshop, Washington, D.C., Sept., 35.
Magura, D. D., and R. F. Mast, 1979. "Ocean thermal energy conversion (OTEC) 10-MWe
preliminary plantship design." Proc. llth Annual Offshore Technology Conf., 3,2059.
Marchand, P., 1980. "The French ocean energy program." Proc. 7th Ocean Energy Conf.,
Washington, D.C., June, 1,2, 2.7.
Marchetti, C., 1987. "The future of hydrogenan analysis at world level with a special look
at air transport." Int. J. of Hydrogen Energy 12(2), 61.
Mast, R. F., 1975. "The ARCO LPG terminal vessel." Conf. on Concrete Ships and Floating
Structures. Berkley, Cal., Sept., 1.
Munier, R. S., T. N. Lee, and S. Chiu, 1979. "Observations of water mass structure and
variability north of St. Croix, U.S. Virgin Islands for OTEC assessment." Proc. 6th
OTEC Conf., Washington, D.C., June, 2, 13.10.
Renner, N., 1989. "Rethinking transportation." in State of the World 1989, WorldWatch Inst.,
p. 101.
Ridgway, S. L., 1977. "The mist flow OTEC plant." Proc. 4th Annual Conf. on Ocean
Thermal Energy Conversion, New Orleans, VIII-37.
Scott, R. J., and W. W. Rogalski, 1978. "Considerations in selection of OTEC platform size
and configuration." Proc. 5th Ocean Thermal Energy Conversion Conf., Miami Beach.,
Fla., Sept., 2, IV-77.
Shea, C. P., 1988. "Renewable energy: Today's contribution, tomorrow's promise."
Worldwatch Paper 81, WorldWatch Inst., Jan. p. 5.
Statistical Abstract of the United States, 1990. U.S. Dept. of Commerce Bureau of the
Census, Table 957.
Uehara, H., 1982. "Research and development on ocean thermal energy conversion in
Japan." Proc. 17th IECEC Conf., American Inst. of Chemical Engineers, 4.
Veziroglu, T. N., 1987. "Hydrogen technology for energy needs of human settlements." Int.
J. of Hydrogen Energy 12(2), 99.
Waid, R. L., 1978. "OTEC platform design optimization." Proc. 5th Ocean Thermal Energy
Conversion Conf., Miami Beach, Fla., 2, IV-1.
Wolff, P. M., 1978. "Temperature difference resource." Proc. 5th Ocean Thermal Energy
Conversion Conf., Miami Beach, Fla., III, 11.
Wolff, W. A., W. E. Hubert, and P .M. Wolff, 1979. "OTEC world thermal resource." Proc.
6th OTEC Conf., Washington, D. C., II, 13-5.
Zener, C., and J. Fetkovitch, 1975. "Foam solar sea power plant." Science, 189, 294.
4
CLOSED-CYCLE OTEC SYSTEMS
The Rankine closed cycle is a process in which beat is used to evaporate a fluid at
constant pressure in a "boiler" or evaporator, from which the vapor enters a piston
engine or turbine and expands doing work. The vapor exhaust then enters a vessel
where heat is transferred from the vapor to a cooling fluid, causing the vapor to
condense to a liquid, which is pumped back to the evaporator to complete the cycle.
A layout of the plantship shown in Fig. 1-2.
The basic cycle comprises four steps, as shown in the pressure-volume (pV)
diagram of Fig. 4-1.1
1. Starting at point a, heat is added to the working fluid in the boiler until the
temperature reaches the boiling point at the design pressure, represented by
point b.
2. With further heat addition, the liquid vaporizes at constant temperature and
pressure, increasing in volume to point c.
3. The high-pressure vapor enters the piston or turbine and expands adiabatically
to point d.
4. The low-pressure vapor enters the condenser and, with heat removal at constant
pressure, is cooled and liquefied, returning to its original volume at point a.
The work done by the cycle is the area enclosed by the points a,b,c,d,a. This
is equal to Hc Hd where H is the enthalpy of the fluid at the indicated point. The
heat transferred in the process is Hc - Ha. Thus the efficiency, defined as the ratio
of work to heat used, is:
Carnot showed that if the heat-engine cycle was conducted so that equilibrium
conditions were maintained in the process, that the efficiency was determined
solely by the ratio of the temperatures of the working fluid in the evaporator and the
condenser.
The maximum Carnot efficiency can be attained only for a cycle in which thermal
equilibrium exists in each phase of the process; however, for power to be generated
a temperature difference must exist between the working fluid in the evaporator and
the warm-water heat source, and between the working fluid in the condenser and
the cold-water heat sink. The rate of heat transfer increases as the temperature
differences are increased, but the pressure difference between the working fluid in
the evaporator and in the condenser is reduced, leading to an optimum distribution
of temperatures in the total system for maximum power production. A theoretical
analysis of the ideal power production process is presented in Wu (1987).
Values of the enthalpy and entropy of fluids that could be considered for use
in OTEC power plants are available in the technical literature; therefore, the
efficiency may be calculated for any Rankine cycle for which the state variables are
known at the points of change in the cycle. The actual values of the variables will
differ from the ideal values because of heat losses in the boiler, pressure losses in
the lines and process equipment, and friction and inefficiencies in the prime mover.
Estimation of the performance of a new design must be based on the use of
manufacturers' specifications for components such as pumps, turbines, and demisters,
and calculated values for temperatures and pressures derived from heat transfer
rates and pressure losses associated with the flow properties, geometry, and
construction. Thermodynamic relationships, combined with measured properties
dependent on temperature and pressure, determine the power that can be generated
92 OCEAN THERMAL ENERGY CONVERSION
for any particular plant design for which heat transfer coefficients and component
efficiencies are known. An elegant analysis of the maximum net OTEC power that
could be produced by an actual design was published by Owens (1979). Detailed
discussion is deferred to Section 4.1.4. The following discussion follows Owens'
exposition. The OTEC power cycle is shown schematically in Fig. 4-2 (Dugger et
al., 1983). The net power of the OTEC power plant is the net power of the thermal
cycle minus the power required for pumping the warm- and cold-water flows to the
evaporator and condenser:
where mcs is the mass flow rate of the cold seawater and Zcv is the sum of three
terms: losses in pressure in water flow through the heat exchanger and associated
ducting, ( pHXC), a pressure loss due to friction of the flow through the cold-water
pipe ( pcwP), and a loss caused by the difference in density between the water in the
CWP and the surrounding warm seawater (Z ):
The temperature range available for the Rankine cycle is restricted to about
half the difference in temperature between warm and cold water by the require-
ments that a temperature difference must exist to enable heat to be transferred from
the warm water to the working fluid in the evaporator, and another must exist for
heat transfer from the working fluid to cold water in the condenser. Thus, the
temperatures and flow variables change as shown in Fig. 4-2.
The principal mechanical components of the closed-cycle heat engine are the
two heat exchangers (evaporator and condenser), the turbine generator, the water
and working-fluid (ammonia) pumps, the demister (which is required for removal
of liquid droplets from the vapor before it enters the turbine), the ducts that conduct
FIG. 4-2. Typical process parameters for the 40-MWe OTEC power system (Dugger et al.. 1983).
CLOSED-CYCLE OTEC SYSTEMS 93
warm and cold water to the heat exchangers, and the ducts that carry working-fluid
vapor and liquid around the cycle. Only the heat exchangers and cold-water pipe
have required development of new technology for application to OTEC.
FIG. 4-3. Schematic design of shell-and-tuhc spray evaporator (Dugger et al.. 1981).
CLOSED-CYCLE OTEC SYSTEMS 95
Laboratory in Japan (Kajikawa et al, 1980). Heat transfer coefficients on the water
side are relatively low because practical flow velocities of from 1 to 2 m/s allow a
thick laminar boundary layer to form on smooth surfaces, which impedes heat
transfer. Various enhancement methods to thin or energize the boundary layer have
been devised, which include surface roughening, extended surfaces, enhancement
devices on the surface, and swirl-inducing techniques. A sketch of proposed
methods is shown in Fig. 4-5 (Lorenz and Yung, 1980).
FIG. 4-4. Fluid flow over a vertical Gregorig surface (Gregorig, 1954).
FIG. 4-5. Types of surface treatments to enhance evaporator heat transfer (Lorenx, and Yung, 1980).
CLOSED-CYCLE OTEC SYSTEMS 97
FIG. 4-6. Schematic design of folded-tube heat exchanger (George and Richards, 1980).
is available on potential performance gains with the use of tubing geometries that
would enhance heat transfer, for example, fluted or twisted configurations, which
are effective in more conventional heat exchanger designs.
4.1.2.3 Working-Fluid Selection
The Rankine closed cycle can employ as a working medium any fluid with an
appropriate vapor pressure at the temperature of the hot source and physical and
chemical properties suitable for the total power system design. Most of the working
fluids developed for air-conditioning systems are potential OTEC candidates.
Desirable Characteristics of Working Fluids. The major factors are:
1. Vapor pressure in the range of 700 to 1400 kPa (100 to 200 psi) at 27C (80oF).
2. Low volume flow of working medium per kilowatt of power produced.
3. High heat transfer coefficient, that is, low thermal resistance to heat transfer
from the bulk vapor to the heat exchanger surface through the liquid film.
4. Chemical stability and compatibility with materials and structures of the power
cycle, including heat exchangers, turbine, seals, and lubricants.
5. Safety.
6. Environmental acceptability.
7. Low cost.
Evaluation of Candidate Fluids. The thermodynamic properties of four
working fluids that are potential candidates for OTEC use are summarized in Table
4-1.
CLOSED-CYCLE OTEC SYSTEMS 99
Table 4-1. Properties of heat engine working fluids of interest for OTEC
(15.56C[60F])
Propertya Ammonia Propane Butane R-22
Formula NH3 C3H8 C4H10 CHF2C1
Molecular weight (M) 17.03 44.09 58.12 123.46
Density(l) (kg/m3) 616.73 508.60 583.73 1229.78
Density(v) (kg/m3) 5.82 16.19 4.61 33.89
Vapor pressure(sat) (kPa) 741.88 741.40 179.40 801.93
Heat of vaporization (kJ/kg) 1214.63 350.63 374.64 193.51
Specific heat(l) (kJ/kg K) 4.68 2.56 2.37 1.22
Specific heat(v) (kJ/kg K) 2.92 2.01 1.76 0.78
Viscosity(l) (Pa s) 1.596 X 10-4 1.199 X 10 -4 1.782 X 10-4 2.121 X 10 -4
Viscosity(v) (Pa s) 1.100 X 10-5 8.681 X 10- 6 7.606 X 10-6 1.277 X 10-5
Thermal conductivity(l) (W/m K) 0.50343 0.101551 0.1211 0.092382
Thermal conductivity(v) (W/m K) 0.02595 0.018684 0.015397 0.01038
B (kPa M kJ/kg) 1.535 X 107 1.146 X 107 3.906 X 106 1.916 X 107
32
Kp /mu 7.796 X 102
1.678 X 10 2
1.889 X 102
1.816 X 102
a
l, saturated liquid; y, vapor.
where k is the thermal conductivity, p the liquid density, and mu the dynamic
viscosity. For a given temperature and tube diameter,
but also for piping, valves, and other structures commonly employed in commercial
equipment. Ammonia does not dissolve grease and oil, which may be used for
lubrication of turbines or valves. This means that if any vapors are generated by
these lubricants, they will tend to deposit and remain on the cool condenser heat
transfer surfaces with eventual degradation of the condenser performance. Hydro-
carbons and Freons do not have these drawbacks; however, the other advantages of
ammonia for OTEC have led to its adoption by most designers. The disadvantages
can be avoided by appropriate system design.
Safety. This item involves consideration of toxicity and fire and explosion
hazards associated with the use of the working fluid. Although the relative values
differ among the fluids, all of those considered for OTEC use are widely used
commercially and are approved for public use in compliance with the safety
standards that have been established.
Because of the large amounts of working fluids that would be involved in
OTEC, special consideration is required of the hazards that would arise with
catastrophic accidents. From this standpoint, the hydrocarbon fluids would be the
most hazardous because any significant leak could form a cloud of denser-than-air
gas that could produce fires and explosions involving the entire amount of working
fluid and destruction of the OTEC vessel or installation. Several hundred tons or
more of flammable hydrocarbons could be discharged in a catastrophic accident
involving a large OTEC plant. The safety regulations of the Interstate Commerce
Commission classify ammonia as a nonexplosive material for shipping and han-
dling. A large leak of ammonia would produce a gaseous mixture that would be
lethal after a few minutes of exposure wherever ammonia concentrations exceeded
one part per thousand. Ammonia is highly soluble in water, and if it were rapidly
mixed with seawater in large amounts, could lead to large heat evolution, boiling,
and vigorous steam production. Concentrations of dissolved ammonia that would
be lethal to marine life could be found to an appreciable distance (a kilometer or
more), depending on ocean currents and mixing rates. The fluorinated hydrocar-
bons are nontoxic and nonflammable but are denser than air. A large spill would
create an asphyxiating cloud, perhaps several hundred meters in diameter.
In view of the widespread safe distribution of hydrocarbons and ammonia by
barge and tanker in quantities of millions of tons per year, as well as the large use
of halogenated hydrocarbons as working fluids in commercial refrigeration, the
hazards of their use for OTEC appear to be small enough to be disregarded in the
choice of optimal working fluids.
Environmental Considerations. Widespread commercial use of OTEC plants
and plantships would inevitably lead to some release of working fluid into the
atmosphere and ocean environments. For hydrocarbons and ammonia, the quanti-
ties emitted would be insignificant in comparison to those associated with industrial
uses of hydrocarbons for transportation and heating, and ammonia uses for
fertilizers. Effects of the fluorine-chlorine-carbon compounds (Freons) are more
questionable because these compounds entering the atmosphere can affect the
ozone layer and in seawater can enter the food chain, becoming progressively
concentrated and eventually reaching possibly toxic concentrations (for example,
CLOSED-CYCLE OTEC SYSTEMS 101
plankton are eaten by small fish that are eaten by larger fish that may be eventually
consumed by humans). Insufficient information is available to allow any estimate
of these potential long-term effects; however, the initial impact would be small, and
time would be available to allow the collection of data and to permit informed
assessments to be made.
Working Fluid Cost. Depending on the power plant design and provisions
for storage, the working fluid cost would be about $5/kW for ammonia and $35/kW
for Freon R-22. Thus, working fluid cost is not a significant consideration in
working fluid selection. Total assessments of all of these factors by the OTEC
community have led to a consensus on the selection of ammonia as the preferred
working fluid for OTEC.
Since heat is extracted as water flows over the heat exchanger surfaces, the
water temperature at the heat exchanger exit is lower than at the inlet. Thus, the rate
of heat transfer from water to ammonia varies with position in the heat exchanger,
and appropriate average values must be used for these quantities. If U does not
depend on AT or flow position in the heat exchanger,
where AT. is the temperature difference between water and working fluid at HX
inlet, Tothe temperature difference between water and working fluid at HX outlet,
Tm the log mean temperature difference, and U the overall heat transfer coefficient.
Equation (4. 1 . 10) is valid for parallel flow, cross flow, and counter flow if the
temperature of the working fluid is constant. This will be approximately true for
OTEC evaporators and condensers. Accurate calculations require finite difference
methods. For OTEC conditions, this refinement is generally not needed. The value
of the coefficient, U, is dependent on the thermodynamic properties of the fluids,
flow velocities, fraction of each fluid vaporized at a particular point in the heat
exchanger pressure, composition and construction of the separator material that
forms the bounding surface between the fluids, character of the surfaces on both
sides of the separator (roughness, presence or absence of scale, biofouling, etc.),
and detailed design and dimensions of the heat exchanger.
As shown in Fig. 1 -7, if a quantity of heat Q flows from water to ammonia,
it must pass first from the water interior to the separating surface. This requires a
temperature difference Tw Tsb, the magnitude of which depends on the character
of the flow at that point, which in turn depends on the local geometry of the flow
passage. The heat then passes through any buildup of corrosion and biofouling on
102 OCEAN THERMAL ENERGY CONVERSION
the water side of the surface, where a further temperature drop, Tsb Tmo, occurs.
Similarly, the heat passes through the other resistances until it is finally absorbed
in the bulk ammonia flow. We then have per unit area,
Also, since
it follows that
Of the terms in Eq. (4.1.13), 1/h w and 1/h a depend on fluid-dynamic parameters
applicable to the specific heat exchanger design. The term 1/h sb is time dependent
and varies with local environment and biofouling countermeasures; x/k can be
accurately calculated from the physical properties and dimensions of the separating
surfaces; and 1/hsa will be unimportant if the working fluid does not become
contaminated with materials that can deposit on the surface, and the wall material
and working fluid are noninteractive. With proper design, this term will be
negligible. Because the physical processes are complex and geometry dependent,
it is generally not possible with actual heat exchangers to predict accurate values of
1/haand 1/hw from basic principles. Many formulas have, however, been derived for
idealized flow situations and correlated with experimental data, which may be used
to provide design and performance predictions for particular heat exchanger
configurations. These are discussed briefly in the following sections, supplemented
by references to the extensive technical literature.
4.1.3.2 Shell-and-Tube Heat Exchangers
Performance prediction requires analysis of the fluid dynamics of water flow in
tubes and of two-phase evaporative and condensing cross flow over the external
surfaces of nested tubes.
Water-Side Heat Transfer and Pressure Drop. Heat transfer rates for single-
phase fluid flow inside long tubes in which turbulent flow is established can be
correlated in terms of the dimensionless quantitiesthe Nusselt number, Nu; the
Reynolds number, Re; and the Prandtl number, Pr (ASHRAE, 1985):
This is equivalent to
CLOSED-CYCLE OTEC SYSTEMS 103
The values of the constant, m, and n depend on the heat loading, tube friction,
and Reynolds number range of operation. For heat exchanger conditions typical of
OTEC operation, the Sieder-Tate relationship is generally used (Holman, 1981):
Usually the final term is omitted and the Sieder-Tate equation is given as
where
The pressure drop (loss of hydraulic head) due to friction in fluid flow through
a straight circular pipe is given by the Fanning equation (Perry and Green, 1984):
The quantity e is a measure of pipe roughness. For drawn tubing, has a value
of approximately 0.0015 mm. For commercial steel pipe, the value is about 0.046
mm. A plot of friction factor versus Reynolds number and surface roughness based
on Eq. (4.1.20) is shown in Fig. 4-7 (Perry and Green, 1984).
FIG. 4-7. Dependence of friction factor on surface roughness and Reynolds number (Perry and Green,
1984).
104 OCEAN THERMAL ENERGY CONVERSION
Table 4-2. Water-side heat transfer and pressure drop for flow in smooth tubes
Water Water Head Pumping
temp. vel. h loss power
(C) (m/s) Re Pr (W/m) (m) (% net power) /
4 3
4.4 0.76 1.26 X 10 11.2 4.5 X 10 0.52 2.59 0.0073
1.5 2.48 X 104 11.2 8.1 X 103 1.69 8.48 0.0061
4 4
2 3.31 X 10 11.2 1.0 X 10 2.80 14.06 0.0057
4
3 4.96 X 10 11.2 1.5 X 104 5.73 28.81 0.0052
4 3
26.7 0.76 2.26 X 10 5.8 6.1 X 10 0.44 2.23 0.0063
4 4
1.5 4.46 X 10 5.8 1.1 X 10 1.47 7.38 0.0053
4 4
2 5.94 X 10 5.8 1.4 X 10 2.45 12.30 0.0050
3 8.91 X 10
4
5.8 2.1 X 104 5.04 25.35 0.0046
Table 4-2 shows that improving heat transfer by increasing water velocity will
be accompanied by sharp increases in water pumping power for conventional heat
exchanger designs. Note that ducting pressure losses and the head requirement
imposed by the higher density of the cold seawater are not included in the table.
Working Fluid Heat Transfer: Pool Boiling. Transfer of heat from a sub-
merged surface to a liquid at a temperature above the boiling point will cause bubble
formation if the temperature and heating rate are high enough to surpass convective
heat transfer to the body of the fluid and if nuclei are available that can initiate
bubble formation at the local fluid temperature. Bubble formation causes a sharp
increase in heat transfer so that the coefficient increases with heating rate; however,
with further heating, the evolved vapor begins to interfere with the access of liquid
to the surface so that the heat transfer rate decreases, eventually reaching a
maximum, as vapor bubbles interfere with heat transfer to the surface. With higher
heat loading the heat transfer rate drops rapidly. Therefore, pool-boiling heat
transfer coefficients are highly dependent on surface characteristics, working fluid
purity, and geometrical factors that affect convection patterns, as well as tempera-
ture differentials and fluid thermodynamic properties. Several equations have been
derived that can be useful in estimating the effects of changes in scale or operating
conditions on the performance of particular designs (Rohsenow, 1952; Holman,
1991; Perry and Green, 1984). A thorough discussion is given by Holman.
CLOSED-CYCLE OTEC SYSTEMS 105
Many methods have been studied for enhancing pool-boiling heat transfer by
alteration of the surface characteristics to promote bubble formation. Porous
coatings formed by spraying or sintering powders or fibers, as well as surface
roughening to create nucleation sites, have been found effective. Order of magni-
tude improvements in the shell-side heat transfer coefficient in comparison with
smooth tubes have been achieved (Berenson, 1962;Czikketal., 1975,1977,1978;
Sabin and Poppendiek, 1977, 1978, 1979; Kajikawa et al., 1980, 1983; Mailen,
1980). The benefits with surfaces coated with piled fibers were investigated in
detail by Kajikawa et al. (1983). Twenty-six kinds of surface structures were used
in the experiments, and an equation was developed relating boiling heat transfer
performance to the physical characteristics of the fiber sintered material. Model
tests in the Argonne facility with a pool-boiling heat exchanger using the Linde Hi
Flux coating indicate that the ammonia-side heat transfer coefficient for OTEC
operating conditions will be in the range of 25.5 to 28.4 kW/m2 K (Thomas et al.,
1980). Mochida et al. (1983) obtained similar values with their enhanced surfaces
by using Freon-type working fluids (Flon). Enhanced tubes of this type were
employed in the pool boiler of the 100-kW demonstration plant at Nauru, which
operated successfully over an 8-month period.
Spray Evaporator. Spray evaporators are designed to distribute a thin film
of the liquid working fluid over all of the tubes so that vaporization takes place from
the film surface or via nucleate boiling. The tube banks are mounted horizontally
to facilitate uniform distribution of the working fluid from nozzles mounted above
the tube banks. Liquid is injected at a rate that will prevent dry-out as the film
progresses down the tubes. Unvaporized fluid drips down to a collecting pool at the
bottom of the tube bank and is recirculated to the spray nozzles. This process is
illustrated in Fig. 4-8 (a-c) (Lorenz and Yung, 1978). Subcooled spray falling on
the top tube of a vertical bank forms a liquid film (a,b). As the fluid flows around
the tube, heat is conducted into the film, changing the temperature profiles, as
shown in (c). When the temperature wave reaches the surface, surface warming
begins and is accompanied by evaporation. With further flow around the tube, a
steady state is reached in which film heating balances film cooling by evaporation.
Depending on mass flow, this condition may be reached before the liquid drips off
the first tube. The liquid then remains at the equilibrium temperature as it drips from
tube to tube to the bottom of the tube bank. For a given surface temperature, the
vapor pressure in the evaporator is then a measure of the Tbetween the tube wall
and the film surface. Nucleate boiling may also occur, varying in intensity with the
number of nucleation sites and the degree of super-heating required to initiate
boiling. The dependence of heat transfer on Reynolds number, Prandtl number, heat
flux, and flow rate for potential OTEC working fluids and operating conditions has
been studied by many investigators (for example, Lorenz and Yung, 1978; Owens
1978). Lorenz and Yung (1978) proposed equations to predict heat transfer rates in
spray evaporators.
Owens (1978), in experiments with ammonia evaporation from a 51-mm-
diameter horizontal stainless steel tube and by using other data for tube banks,
showed that the following correlations are valid for OTEC, within 10% (see Fig.
4-9).
106 OCEAN THERMAL ENERGY CONVERSION
FIG. 4-8. Working fluid evaporation from horizontal tubes in a spray evaporator (Lorenz and Yung,
1978).
where H is the distance between the top and bottom of two adjacent tubes in a
column.
CLOSED-CYCLE OTEC SYSTEMS 107
FIG. 4-9. Predicted heat transfer in NH3 flow over horizontal tube banks (Owens, 1979).
Predictions by Owens (1978) for ammonia and other potential OTEC working
fluids are shown in Fig. 4-10. The Owens values are about 10% above those
predicted by Lorenz and Yung. Either of the sets of equations appears satisfactory
for predicting working-fluid-side heat transfer coefficients for smooth horizontal
tubes. Major improvements are possible in heat transfer coefficients with surface
enhancements that promote nucleate boiling or thinning of the flowing film. For
thin film evaporation of ammonia, Sabin and Poppendiek (1978) compared the
conductances of films on smooth tubes with those on tubes having five types of
enhanced surfaces: (1) porous nickel plating, (2) Linde Hi Flux, (3) fine turned
and burnished grooves, (4) diamond knurl, and (5) straight knurl. As shown in
Fig. 4-11 the diamond knurled surface gave the best results, slightly better than the
Linde surface. The improvement is between two and three times, depending on
weight flow, compared with the smooth tube. Czikk et al. (1978) measured the film
conductances in a test bundle of 13 Hi Flux-coated tubes. Heat transfer values range
from 28.4 to 34 kW/m2 K, and the heat flux varied from 9.5 to 30 kW/m2. The
performance was essentially the same as for the pool-boiling condition. A test of the
horizontal spray evaporator with Hi Flux-coated tubes at Argonne National
Laboratory (ANL) gave a value of 26.0 kW/m2 K (Panchal et al., 1981).
Condensation. In the horizontal shell-and-tube condenser, vapor enters the
shell side and condenses as it impinges on the tube surfaces, forming a liquid film
that drips from tube to tube in the bank, finally flowing to the collecting pool at the
bottom. The process is described in detail by Holman (1981). Nusselt showed that
for laminar flow over the tubes, the average heat transfer coefficient was given by
the following equation:
108 OCEAN THERMAL ENERGY CONVERSION
FIG. 4-10. Predicted heat transfer in spray evaporators with various working fluids (Owens, 1978).
FIG. 4-11. Heat conductance in ammonia films on various surfaces (Sabin and Poppendiek, 1978).
where n is the number of tubes in a vertical bank. The coefficient will increase by
about 20% if ripples form in the film, which is generally the case. Equation (4.1.23)
may be expressed as a function of the Reynolds number:
FIG. 4-12. Schematic of CMU vertical heat exchangers. Condenser: left; evaporator: right (Rothfus
and Lavi, 1978).
110 OCEAN THERMAL ENERGY CONVERSION
University confirmed the predicted improvement and led to the design and
construction of a fluted evaporator and condenser for tests at ANL. The flutes were
a constant 0.66-mm radius machined on the outer surface of a 25.4-mm-diameter
tube. The area ratio compared with the smooth 25.4-mm-diameter tube was 1.50
(Rothfus and Neumann, 1977). Tests were conducted with both ammonia and Freon
R-ll. Heat transfer enhancement factors of 3 to 5 were demonstrated. Extensive
studies of longitudinally fluted tube condensers were done by Ueharaet al. (1978),
Suematsu (1974), and Miyoshi et al. (1977) using water, R-ll, and R-113 as
working fluids. Tube diameters of 25.4 and 51 mm, flute heights of 0.15 to 1.07 mm,
and flute pitches of 1.0 to 3.6 mm were studied. Smooth tubes were also included.
The data were correlated by the relationship:
where Nu is the Nusselt number, d the flute depth, P the flute pitch, Ga the Galileo
number = gl3/v3 I the effective length of fluted tube, H = C (Tsat - TW)/L, L the latent
heat of vaporization, and v the viscosity.
For the Freons, the constant had a value of 0.94 for smooth tubes, 1.8 for the
tube with flute height 0.15 mm and 2.00-mm pitch, and 2.6 for the remaining tubes.
Additional experiments by Kawano et al. (1983) with a series of fluted tube designs
have shown that the equation in the figure correlates all of the experimental results
within 20%, including the data of Uehara et al. (Fig. 4-13).
FIG. 4-13. Heat transfer coefficients for downward flow over fluted lubes (Uehara, 1978).
CLOSED-CYCLE OTEC SYSTEMS 111
The Nusselt number for the fluted tubes was found to be 1.5 to 7 times the value
for smooth tubes. A cross-sectional view of the fluted tubes is shown in Fig. 4-14
(Kawano et al., 1983). The experimental data show the highest heat transfer
coefficient for the fluted tube with 1-mm groove pitch and 0.5-mm groove depth
(tube 3). This tube design was adopted for the proposed 100-kW demonstration
plant. Although vertical flutes are effective in increasing heat transfer, with long
tubes the liquid film floods the surface, causing the heat transfer coefficient to
approach smooth tube values. The difficulty may be alleviated by providing gutters
or separators at intervals to drain off the film. In the demonstration plant, separators
were provided at 1.2-m intervals. Various methods have been devised for prevent-
ing buildup of thick films. A wire-wrapped configuration developed by Linde was
tested at ANL (Thomas et al., 1979). Studies have also been made by Webb (1978),
Combs (1979), and Kajikawa et al. (1979), among others. Takazawa et al. (1983)
showed that spirally fluted tubes with drainage gutters, as shown in Fig. 4-15, could
be particularly effective. The heat transfer coefficient of the tube that gave the best
performance is compared with the smooth tube in Fig. 4-16. This shows an
enhancement ratio of 4 for a heat duty of 8.9 kW/m2, which is the design value for
the 100-kW demonstration plant.
4.1.3.3 Plate Heat Exchangers
Plate heat exchangers have long been used for forced-convection heat transfer
between two liquids. Their use for OTEC was explored by Alfa-Laval as part of the
European program begun in 1970 to explore industrial uses of the oceans
(Lachmann, 1978). Heat exchangers made from thin plates separated by gaskets
designed to channel the water and working fluid between alternate corrugated
FIG. 4-14. Profiles of tube surfaces used in fluted tube condensation tests (Kawano et al., 1983).
112 OCEAN THERMAL ENERGY CONVERSION
FIG. 4-15. Design of spirally fluted tube with drainage gutters (Takazawa et al., 1983).
FIG. 4-16. Working fluid heat transfer with smooth and spirally grooved tubes (Takazawa et al., 1983).
CLOSED-CYCLE OTEC SYSTEMS 113
plates had been developed by Alfa-Laval for a variety of applications, but new
designs were required for two-phase flow (Berndt and Connell, 1978). A schematic
view of the design is shown in Fig. 4-17. A plate heat exchanger supplied by Alfa-
Laval was used in the Mini-OTEC demonstration (Owens and Trimble, 1980), and
was also tested in the ANL program (Panchal et al., 1981, 1984). Tests of a
commercial plate heat exchanger made by the Tranter Company were also con-
ducted in the ANL program (Panchal et al., 1983).
The corrugations on the heat exchanger plates act as Gregorig surfaces to
enhance heat transfer and also increase the heat transfer area by 20 to 30% relative
to the projected area. They also provide structural rigidity and serve to distribute the
fluid flow uniformly. The plate surfaces may also be coated with thin layers of fibers
or powders to enhance nucleate boiling. In combination, these features can permit
maj or reductions to be made in the size of OTEC heat exchangers; however, the heat
transfer advantages of the plate heat exchanger tend to be accompanied by
significant pressure drops, which reduce the system benefits. The plate concept may
be extended to include thin plates that may be formed and combined by welding or
adhesives to carry water and working fluid in parallel channels, with heat transfer
through a dividing wall. Such designs may offer great advantages in volume
reduction and constructibility. Anderson and associates explored the potential
FIG. 4-17. Schematic view of Alfa-Laval plate heat exchanger (Berndt and Connell, 1978).
114 OCEAN THERMAL ENERGY CONVERSION
benefits of several variations of this approach (Anderson and Anderson, Jr., 1977;
Anderson, 1978; Anderson and Pribis, 1979; Anderson et al., 1980). A drawing of
a recent test configuration, designed to be suitable for scale-up to OTEC sizes, is
shown in Fig. 4-18 (Anderson et al.,1980).
A modification of the plate concept that combines compact design and ease of
fabrication with high performance, and avoids sealing and crevice corrosion
problems, has been proposed by the Trane Company (Ashworth and Slebodnick,
1980; Foust, 1981). The concept is illustrated in Fig. 4-19. Aluminum billets are
extruded to form flat plate sections with internal water passages, as shown.
Longitudinally corrugated sections are rolled from thin aluminum sheet to form
ammonia flow channels. The heat exchanger is then constructed by aligning the
plates alternately and brazing the assembly. A diagonal cut enables two ammonia
sections to be joined at right angles so that ammonia can enter the channels
horizontally at the top, then turn to flow vertically, until it reaches the bottom where
another diagonal cut returns the flow to the horizontal direction. A cutaway view
of the assembly is shown in Fig. 6-25. Water flows downward under gravity from
pools above the heat exchangers. This simplifies ducting and makes the water
channels easily accessible for inspection and cleaning. A heat exchanger of this type
was tested at the 1-MWt level at ANL (Panchal et al., 1981).
FIG. 4-18. Compact heal exchanger of the Andersons' design (Anderson et al., 1980).
CLOSED-CYCLE OTEC SYSTEMS 115
FIG. 4-20. Design of JHU/APL 2.5-MWe folded-tube heat exchanger module (George and Richards,
1980).
proposed that correlate experimental data for internal two-phase flow for specific
designs, working fluids, and operational conditions. Since the heat transfer and flow
resistance progressively change as the fluid moves forward, the use of average
values derived from inlet and outlet measurements can be misleading and should
be used with caution, particularly in comparisons of overall heat transfer behavioi
from one type of heat exchanger to another. Data on water-side heat transfer and
internal two-phase flow ammonia heat transfer, directly applicable to OTEC heal
exchanger conditions, were obtained in experimental programs conducted at JHU/
APL (Pandolfini et al., 1978,1980). These were followed by tests at the first on-land
OTEC installation at Kea-Hole Point, Hawaii (Pandolfini et al., 1977). Data on
overall heat transfer were measured later at the 1-MWt test facility at ANL. In the
initial tests, water-side and ammonia-side heat transfer rates and pressure drops
were measured separately.
Water-Side Heat Transfer. The assembly shown schematically in Fig. 4-21
was used for the water-side measurements. Instrumented, electrically heated tubes,
as shown in Fig. 4-22, were placed at the indicated positions for heat transfer
measurements, and pressure sensors measuring p were placed above and below
the tube bank. Heat transfer rates varied with radial position on the tubes and were
slightly different for the upper and lower tubes, compared with tubes internal to the
bank. The data were correlated by the Zukauskas formula:
The measured values were roughly 25% higher than those predicted by the formula
(Pandolfini et al., 1981; Afgan and Schlunder, 1974).
Water-Side Pressure Drop. The pressure drop in flow across a staggered
bank of tubes is given by the following relationship:
where Eu is the Euler number -0.1 for the folded-tube bank, Vm the water velocity
at minimal clearance between tubes, and N the number of tubes in one vertical
column.
Measured values of the variation of pressure loss with flow velocity are shown
in Fig. 4-23. The graph indicates a small decrease in Euler number with Reynolds
number.
Ammonia-Side Heat Transfer. Heat transfer coefficients for internal two-
phase flow of ammonia were measured by using the apparatus shown schematically
in Fig. 4-24 (Keirsey et al., 1979). By adjusting the heat input to the steam preheater,
ammonia at any desired quality (mass percentage of vapor to total mass) could be
introduced to the electrically heated test section, from subcooled to 20% quality.
Wall surface temperature measurements and ammonia pressures were then used to
derive heat transfer coefficients. In the all-liquid flow regimes, heat transfer rates
agreed reasonably well with the Dittus-Boelter correlation:
FIG. 4-21. Drawing of apparatus for measuring water-side heat transfer in folded-tube HX (Pandolfini
etal., 1977).
FIG. 4-22. Instrumented tube used in water-side heat transfer measurements (Pandolfini et al., 1977).
CLOSED-CYCLE OTEC SYSTEMS 119
FIG. 4-23. Variation of pressure loss with water velocity in folded-tube heat exchanger tests
(Pandolfini et al., 1981).
FIG. 4-24. Diagram of apparatus for measuring heat transfer in internal two-phase flow of ammonia
(Kcirsey et al., 1979).
120 OCEAN THERMAL ENERGY CONVERSION
where h is the two-phase flow heat transfer coefficient, Bo the boiling number =
(Q/A)p 1 v 1 H, and X the Martinelli parameter
The experimental results for the two-phase flow regime are presented in Fig. 4-25.
Ammonia-Side Pressure Drop. The pressure drop in two-phase flow may be
estimated by use of a correlation proposed by Chisholm (Collier, 1972):
where x is the vapor mass quality and p1 is the all-liquid pressure drop given by
the Fanning equation for the same conditions:
FIG. 4-25. Variation of liquid ammonia heat transfer w i t h flow velocity in internal flow (Pandolfini
etal., 1980).
CLOSED-CYCLE OTEC SYSTEMS 121
FIG. 4-26. Ratio of two-phase flow to all liquid heat transfer in ammonia internal flow (Pandolfini et
al., 1981).
for demonstration-size OTEC power units. A nominal heat loading of 1 MWt was
selected for the tests, and participants in the OTEC program were encouraged to
fabricate innovative heat exchanger designs for comparative evaluations. Particu-
lar care was taken to ensure accuracy in the measurement of heat inputs and outputs
and pressure drops across the exchangers so that accurate values of overall heat
transfer and pumping losses could be obtained. It was not feasible to measure the
water and working fluid heat transfer coefficients directly. These values were
inferred, via the Wilson plot procedure, that is, from the measured change in the
overall heat transfer coefficient at constant heating rate when the flow rate of one
fluid was varied while the other fluid was held constant. The facility design,
instrumentation, and methods of data analysis are described in Sather et al. (1978)
and Lewis and Sather (1978). The careful design of the equipment and operating
procedures is attested by the accuracy of the data, which were reproducible within
a few percent. A schematic of the test loop is shown in Fig. 4-27.
4.1.4.1 Linde Flooded-Bundle Evaporator
The Union Carbide flooded-bundle test evaporator, of conventional horizontal
shell-and-tube design, employed a proprietary surface coating called Hi Flux on the
shell side of 3. 8-cm-OD titanium tubes. Tests were conducted during November
and December 1978 and were supplemented by additional experiments during
March to May 1979. Details of the tests are given in Lewis and Sather (1978). A
schematic of the heat exchanger is presented in Fig. 4-28. Nominal design
parameters are listed in Table 4-3,
122 OCEAN THERMAL ENERGY CONVERSION
FIG. 4-27. Schematic of ANL test facility for 1 -MWt model heat exchangers (Lewis and Sather, 1978).
FIG. 4-28. Diagram of Linde flooded-bundle evaporator (Lewis and Sather, 1978).
CLOSED-CYCLE OTEC SYSTEMS 123
Table 4-3. Nominal design parameters for the Linde flooded-bundle evaporator
Parameter English units SI units
Heat duty 3.2 MBtu/h 0.94 MWt
Ammonia inlet temperature 72F 22.22C
Water inlet temperature 80F 26.67C
Water outlet temperature 78F 25.56C
Number of tubes 279 279
Hi Flux-coated tube length 75 in. 1.90m
Tube outside diameter 1.5 in. 0.139m
Tube inside diameter 1.43 in. 0.133m
Effective outside heat transfer area" 685 ft2 63.63 m2
Mean water velocity in tubes 6.8 ft/s 2.07 m/s
Overall water-side pressure drop 2.75 psia 18.96kPa
Shell inside diameter 49 in. 1.24m
Shell-side design pressure 215 psig 1482 kPa
Tube-side design pressure lOOpsig 689 kPa
"Clean" overall heat transfer coef. 768 Btu/ft 2 h F 4365 W/m2 C
"Based on actual coated tube length of 75 in.; the total tube length between tube sheets is 2.75 in. longer.
"Based on outside tube surface area. Assumes no tube-side or shell-side fouling.
The tests fully confirmed the predicted improvement in the overall heat
transfer coefficient through the use of the Hi Flux surface coating. A summary of
the test results in normal operation is given in Table 4-4, showing a value of
U = 4336 W/m2 C and pressure drop of 18.8 kPa for the nominal water velocity of
2.1 m/s. The variation of water-side heat transfer with water velocity is shown in
Fig. 4-29. The observed data are correlated by the following equation:
As in other experiments, the measured values are about 20% above the
predictions of the Sieder-Tate and Dittus-Boelter correlations. An unexpected
observation during the tests was that the surface tended to become deactivated if
liquid ammonia was allowed to stand in contact with the surface under nonboiling
conditions. The effectiveness of the surface was restored in operation, but approxi-
mately 100 h of operation was required for the full effectiveness to be regained.
Table 4-4. Values of U 0 as a function of water flow rate for the Linde flooded-bundle
evaporator
Flow rate U0 Ap
gpm kg/s Btu/ft W/m C 20
psi kPa
1492 97 514 2917 0.57 3.93
2404 156 665 3775 1 .55 10.68
3171 205 764 4336 2.72 18.75
4008 259 840 4768 4.32 29.78
4997 323 909 5159 6.61 45.57
124 OCEAN THERMAL ENERGY CONVERSION
FIG. 4-29. Variation of water-side heat transfer with flow rate in Linde flooded-bundle evaporator
(Lewis and Sather, 1978).
For the spray evaporator setup, the pressure drop was 27.6 kPa (including
ducting losses), a significantly higher pumping power requirement than for the
flooded-bundle design. As with that design, the enhanced surfaces were deactivated
by being allowed to remain in contact with nonboiling liquid ammonia. For this
CLOSED-CYCLE OTEC SYSTEMS 125
Table 4-5. Nominal design parameters for the Linde sprayed-bundle evaporator
Parameter English units SI units
Heat duty 3.2 MBtu/h 0.94 MWt
Ammonia inlet temperature 72F 22.22C
Water inlet temperature 80F 26.67C
Water outlet temperature 78F 25.56C
Number of tubes 388 388
Hi Flux-coated tube length 55 in. 1.40m
Tube outside diameter 1.5 in. 0.038 m
Tube inside diameter 1.43 in. 0.036 m
Effective outside heat transfer area" 698 ft2 64.7 m2
Mean water velocity in tubes 6.6 ft/s 2.01 m/s
Water-side pressure dropb 2.1 psi 14.5 kPa
Shell inside diameter 71 in. 1.803m
Shell-side design pressure 215psig 1482 kPa
Tube-side design pressure 100 psig 690 kPa
"Clean" overall heat transfer coef.c 740 Btu/ft2 h F 4200W/m 20 C
a
Based on actual coated tube length of 55 in.; the total tube length between tube sheets is 6 in. longer,
b
Does not include tube and nozzle inlet and exit losses.
c
Based on outside lube surface area. Assumes no lube-side or shell-side fouling.
126 OCEAN THERMAL ENERGY CONVERSION
Table 4-6. Values of Uo as a function of water flow rate for the Linde sprayed-bundle
evaporator
Flow rate Uo
2
gpm kg/s Btu/ft h F W/m20C
1502 95 500 2837
2384 150 637 3615
3177 200 760 4313
4012 253 835 4738
5004 315 905 5135
Table 4-7. Nominal design parameters for the Linde enhanced-tube condensers
Parameter English units SI units
Heat duty 3.2 mBtu/h 0.94 MWt
Ammonia condensing temperature 48F 8.9C
Water inlet temperature 40F 4.4C
Water outlet temperature 42F 5.6C
Number of tubes 147 147
Externally enhanced tube length 154.5 in. 3.92m
Tube outside diameter (excluding wrapped wire) 1 .50 in. 0.0381 m
Tube inside diameter 1.37 in. 0.0348 m
Effective outside heat transfer area" 743 ft2 69.1 m2
Mean water velocity in tubes 4.7 ft/s 1.43m/s
Overall water-side pressure drop 2.0 psiab 13.8 kPa
Shell inside diameter 29.25 in. 0.743 m
Shell-side design pressure 2l5psig 1482 kPa
Tube-side design pressure l00 psig 690 kPa
"Clean" overall heat transfer coef.' 740 Btu/ft 2 h F 4427 W/m 20 C
a
Based on outside diameter without wrapped wire and on actual enhanced tube length of 154.5 in., the total tube
length between the tube sheets is 6.4 in. longer.
b
Based on communication with Union Carbide, Linde Division, Tonawanda, New York.
c
Based on outside lube surface area. Assumes no tube-side or shell-side fouling.
CLOSED-CYCLE OTEC SYSTEMS 127
FIG. 4-32. Details of Linde condenser tube design (Yung et al, 1979).
Table 4-8. Heat transfer and pressure drop for Linde enhanced-tube condenser
(Yung et al., 1979)
Water flow 0 p
2 2
gpm kg/s Btu/h ft F W/m K psi kPa
FIG. 4-33. Water-side heat transfer coefficient versus water flow rate in Linde condenser (Yung et al.,
1979).
The measured values are from 1.5 to 1.75 times the Sieder-Tate predictions
for smooth tubes of the same nominal diameter. Since the actual wetted area was
1.8 times the smooth-tube area, reasonable agreement would result from substitut-
ing the actual wetted perimeter of the fluted tube for the smooth-tube value in the
Sieder-Tate equation. The experimental program also included tests that showed
that the ammonia-side heat transfer was not affected by the heat duty, within the
range from 13,620 to 22,700 W/m2 C. This implies that the average thickness of
the condensing film is effectively maintained at a constant level by the wire-
wrapping technique.
CLOSED-CYCLE OTEC SYSTEMS 129
FIG. 4-34. Diagram of CMU evaporator test vessel (Lorenz et al., 1979).
130 OCEAN THERMAL ENERGY CONVERSION
For the nominal operating conditions, the overall heat transfer coefficient, U,
was 4680 W/m2 K, and the pressure drop was 22.1 kPa. The value of U is based on
surface areas computed as 2 times the mean inside and outside diameters times the
total tube length. If the actual area were used, the U value would be 2264 W/m2 K.
The value of ha computed from a Wilson plot was 10,214 W/m2 K. This is 2.5 times
the smooth-surface value that would be predicted by the Chun-Seban correlation.
Since the enhanced area due to fluting was 1.85 times the smooth-tube area, it is
apparent that the flutes produced the beneficial behavior predicted by Zener and
Lavi (1973). The water-side heat transfer coefficient was 1.95 times the smooth-
tube value computed by using the Sieder-Tate equation. This value is in close
agreement with the enhancement in internal area by a factor of 2.07 due to the water-
side fluting. Figure 4-36 and Tables 4-10 and 4-11 summarize the test results.
CLOSED-CYCLE OTEC SYSTEMS 131
Table 4-9. Nominal design parameters for the CMU vertical fluted-tube evaporator
Parameter English units SI units
Heat duty 3.2 MBtu/h 0.94 MWt
Ammonia evaporating temperature 72F 22 22C
Water inlet temperature 80F 26.67C
Water outlet temperature 78F 25.56C
Number of tubes 240 240
Tube length 172 in. 4.4 m
Tube outside diameter (to midpoint of flutes) 1.218 in. 0.031 m
Tube inside diameter (to midpoint of flutes) 0.915 in. 0.023 m
Outside heat transfer area" 1097 ft2 102.0 m2
Mean water velocity in tubes 6.5 ft/s 1 .98 m/s
Overall water-side pressure drop 2.7 psia 18.6kPa
Shell inside diameter 42.25 in. 1.07m
Shell-side design pressure 215 psig 1482 kPa
Tube-side design pressure 1 00 psig 690 kPa
FIG. 4-36. Heat transfer results in tests of the CMU evaporator (Lorenz et al., 1979).
132 OCEAN THERMAL ENERGY CONVERSION
Table 4-10. Values of U0 as a function of water flow rate for the CMU fluted-tube
evaporator
Water flow velocitya v, )
"The gpm values can be converted to tube-side velocity v (ft/s) by the relationship v = 0.002033w.
Table 4-11. Values of hi as a function of water flow rate for the CMU fluted-tube
evaporator
Water flow rate hi
2
gpm kg/s Btu/ft h F W/m 20 C
1510 95 1431 8120
2420 152 2047 11616
3200 202 2610 14810
4050 255 3 1 50 17875
4940 311 3692 20950
The tests showed that the results were not reproducible if the tubes were
allowed to dry out, presumably because of difficulty in re-establishing surface
wetting. It also appeared that the applicator did not produce uniform films at the tops
of the tubes, which caused scatter in the data.
The CarnegieMellon condenser, shown in Fig. 4-37, was of the same general
design as the Carnegie-Mellon evaporator. It employed fluted aluminum tubes, of
3.09 cm average OD and 2.33 cm average ID. Details of the tube design are shown
in Fig. 4-38 (Lewis and Sather, 1979). The nominal design parameters are given in
Table 4-12.
The performance of the condenser was in accord with the predictions of the
bench-scale tests conducted by the Carnegie-Mellon group. At the nominal
conditions, U was 5918 W/m2 K, and the water-side pressure drop was 23.0 kPa. As
with the evaporator, the U value is based on the projected area of the tubes. If the
actual surface areas are used for the calculation, the value of U is 2917 W/m2 K for
the nominal test conditions. The ammonia heat transfer coefficient deduced from
Wilson plots at heat duties of 2.3,3.2, and 4.0 X 106 kJ/h shows an increase in value
from 18,556 to 21,166 W/m 2 K. This result shows that the film thickness under the
test conditions did not reach the critical loading values. The Sieder-Tate equation
would predict a value of U of 2463 W/m 2 K for a smooth tube of this diameter. The
experimental result is in accord with other observations that give about 20% higher
overall heat transfer values for smooth tubes than the Sieder-Tate equation.
CLOSED-CYCLE OTEC SYSTEMS 133
FIG. 4-38. Diagram of CMU condenser tube design (Lewis and Sather, 1979).
A series of experiments was made with the Alfa-Laval plate heat exchanger
at several values of heat flux to measure the effects of flow rates of water and
ammonia on overall heat transfer and pressure (Panchal et al., 1983). Three types
of corrugation (chevrons) were tested. Both ammonia and Freon 22 were used as
working fluids. The data for these tests are shown in Tables 4-14 and 4-15.
The results of the evaluation of the Hi Flux coating on the performance of the
Tranter heat exchanger are shown in Table 4-16.
4.1.4.6 Japanese Plate Heat Exchangers (Saga University)
Extensive tests of plate heat exchangers were conducted by Uehara and associates
at Saga University (1978, 1983). Both ammonia and R-22 were used as working
fluids. The fluid distributions are indicated in Fig. 4-40. Specifications for the plates
are given in Table 4-17.
CLOSED-CYCLE OTEC SYSTEMS 135
Table 4-12. Nominal design parameters for the CMU vertical fluted-tube condenser
Parameter English units SI units
Heal duty 3.2 MBtu/h 0.94 MWt
Ammonia inlet temperature 48F 8.89C
Water inlet temperature 40F 4.44C
Water outlet temperature 42F 5.56C
Number of tubes 240 240
Externally enhanced tube length 172 in. 4.37m
Tube outside diameter (to midpoint of flutes) 1.2 18 in. 0.0309 m
Tube inside diameter (to midpoint of flutes) 0.915 in. 0.0232 m
Effective outside heat transfer area" 109 ft2 10.13m 3
Mean water velocity in tubes 6.5 ft/s 1 .98 m/s
Overall water-side pressure drop 2.95 psi 20.3 kPa
Shell inside diameter 42.25 in. 1.073m
Shell-side design pressure 215psig 1482kPa
Tube-side design pressure lOOpsig 690 kPa
''Clean" overall heat transfer coefficient b 1045blu/ft 2 hF 5930 W/m 2 C
a
Based on outside tube diameter to midpoint of flutes.
b
Based on mean outside tube surface area (1097 ft 2 ). Assumes no tube-side or shell-side fouling.
FIG. 4-39. Diagram of Alfa-Laval heat exchanger construction (Panchal et al., 1983).
136 OCEAN THERMAL ENERGY CONVERSION
Table 4-14. Effects of chevron angles on the overall performance of the Alfa-Laval
plate heat exchanger
Water-side Overall heat transfer
pressure drop coefficient
Run Heat flux H2O flow rate NH, flow rate (kPa) (kW/m2 K)
no. (kW/m2) (kg/s/channel) (kg/s/channel) M" H L M" H L
1 6.98 1.55" 0.023 44.1 102.0 13.1 3.29 3.47 2.56
2 6.96 2.26 0.035 92.4 203.4 25.5 3.55 3.68 2.84
3 7.04 0.97 0.047 15.2 40.7 3.4 3.17 3.41 2.34
4 10.00 1.03 0.510 17.2 46.2 4.1 3.37 3.73 2.44
5 9.96 1.67 0.039 47.6 116.5 14.5 3.63 3.92 2.71
6 11.94 1.55 0.039 42.1 99.3 13.1 3.75 3.84 2.67
7 11.95 2.25 0.058 89.6 202.0 26.2 4.15 4.34 3.00
8 11.99 0.9 K 0.045 16.6 35.5 4.14 3.41 3.59 2.37
a
M = mixed plates; H - high-angle plates; L - low-angle plates.
b
Water flow rate for mixed plates was 1.60 kg/s/channel.
c
Water flow rate for mixed plates was 0.97 kg/s/channel.
Table 4-16. Comparison of the thermal performance of the Tranter plate heat exchanger
with smooth and with Linde Hi Flux surface
With Hi Flux surface
Smooth Same heat Same approach Same mean temp.
surface flux temperature" differenceb
FIG. 4-40. Fluid flow in Saga University plate heat exchangers (Uehara et al., 1983).
Table 4-17. Specifications of plates for the Saga University heat exchangers
Item S plate IP plate P plate No. 1 plate No. 2 plate
Length (mm) 1255 1255 1450 1255 1450
Width (mm) 415 415 235 415 235
Thickness (mm) 0.8 0.8 1.0 0.8 1.0
Material titanium titanium titanium titanium titanium
Number 60 50 100 54 168
Total surface area (m 2 ) 20.8 8.16 21.95 21.6 40.7
138 OCEAN THERMAL ENERGY CONVERSION
Results of the Uehara tests parallel those of Panchal et al. (1983). The best plate
configurations enhance overall heat transfer by a factor of about 4 in comparison
with the smooth plate. Plots of overall heat transfer coefficient versus water flow
velocity are shown in Fig. 4-41 for the evaporator and Fig. 4-42 for the condenser.
Pressure loss (hydraulic head) as dependent on water velocity is shown in Figs. 4-
43 and 4-44.
4.1.4.7 Folded-Tube Heat Exchanger (Johns Hopkins University APL)
The JHU/APL folded-tube heat exchanger constructed for the ANL test had three
7.62-cm-OD (3 in.) folded tubes, each folded into 43 passes and mounted in a
vertical plane. Ammonia flowed inside the tubes, and water flowed externally from
FIG. 4-41. Heat transfer versus water flow for Saga University plate evaporators (Uehara ct al., 1978,
1983).
CLOSED-CYCLE OTEC SYSTEMS 139
FIG. 4-42. Heat transfer versus water flow for Saga University plate condensers (Ueharaet al., 1978,
1983).
a head pond above the tubes. The equipment was designed to permit swirlers to be
inserted in the three inlet tubes of the evaporator to test whether they would improve
the heat transfer at the low flow velocity of the first pass. A diagram of the ANL test
article is shown in Fig. 4-45 (Yung et al., 1981). The heat exchanger was tested both
as an evaporator and as a condenser. Operation was unusually stable and reproduc-
ible. The performances of both the evaporator and condenser exceeded predictions
based on published correlations and earlier smaller-scale experiments. This re-
140 OCEAN THERMAL ENERGY CONVERSION
FIG. 4-43. Pressure loss (hydraulic head) versus water flow velocity for Saga University plate
evaporator (Uehara et al., 1983).
where P is the pressure (psi); mA, the ammonia flow rate (1b/s); and Q, the heat
loading (10 6 Btu/h).
CLOSED-CYCLE OTEC SYSTEMS 141
FIG. 4-44. Pressure loss (hydraulic head) versus water flow velocity for Saga University plate
condenser (Ueharaet al., 1983).
FIG. 4-45. Diagram of test module for JHU/APL folded-tube heat exchanger (Yung et al., 1981).
Heat transfer rates for the condenser are shown in Fig. 4-47. Analysis of the
data showed that the stratified flow model of Nusselt accurately predicted the heat
transfer rates over the expected OTEC operating range. For this model (Collier,
1972):
FIG. 4-46. Heat transfer versus flow rates of water and ammonia in ANL tests of the JHU/APL folded-
tube evaporator (Yung et al, 1981).
Water flow = 3200 gpm (v = 2.54 ft/s); ammonia flow = 1.0 lbm/s/tube; heat duty = 3.2 X 106 Btu/h; exit quality
= 58%.
"Average ammonia inlet subeooling. Standard deviation for 7 runs with swirlers = 9.0 2.40F, and for 4 runs without
swirlers = 7.3 2.4F.
144 OCEAN THERMAL ENERGY CONVERSION
FIG. 4-47. Heat transfer versus water flow velocity in ANL tests of the JHU/APL folded-tube
condenser (Yung et al., 1981).
CLOSED-CYCLE OTEC SYSTEMS 145
In the stratified flow regime, vapor condenses at the tube wall and flows down
the sides, forming a channel of liquid ammonia at the bottom that increases in depth
as the vapor progressively condenses toward the end of the tube. As vapor flow rates
increase, the liquid flow at the bottom is thrown more and more to the sides and top,
eventually producing the condition called annular flow. The test results show that
stratified flow analysis applies to flow rates up to about 0.39 kg/s in the 0.068-m-
ID folded tube, after which a combination of equations for annular flow and
stratified flow gives better agreement with the measured results. (The nominal
OTEC value of ammonia flow for the ANL tests was 0.32 kg/s. Algorithms for
finding ha were developed by Pandolfini et al., 1981).
A comparison of the observed overall heat transfer coefficients with the
predictions of stratified and annular flow models is shown in Fig. 4-48.
FIG, 4-48. Heat transfer in two-phase flow of ammonia in tests of the JHU/API. folded-tube condenser
(Pandolfini el al., 1983).
146 OCEAN THERMAL ENERGY CONVERSION
FIG. 4-49. Design of Rocketdyne axial-fluted heat exchanger tube (Panchal et al., 1981).
CLOSED-CYCLE OTEC SYSTEMS 147
produced by OTEC plants of various types. The analysis follows the exposition of
Owens (1983), to which the reader is referred for details. Owens derived a closed-
form solution for the OTEC thermal cycle that permits the maximum net power to
be expressed in terms of the optimum saturation temperature difference, which is
shown to be dependent for a particular design only on the seawater temperature
difference and constants associated with vapor and condensate flow. The net power
per unit of total heat exchanger area is then shown to be primarily dependent only
on the heat transfer coefficients as dependent on seawater flow velocities in the
evaporator and condenser, and on the associated pressure losses, which can be
defined in terms of the length to hydraulic diameter ratios. With the Owens analysis
a computer program can be used to predict the power output of OTEC plants
designed to employ heat exchangers of the advanced types tested in the ANL
program. The optimum selections of flow conditions are then displayed as a ratio
of net power output to maximum theoretical output.
A summary of the model heat exchanger test conditions, the heat transfer
coefficients, and pressure drops measured by ANL, for which complete data have
been reported by ANL, is given in Table 4-21. The data are used to predict the OTEC
power plant performance, using the Owens analysis procedure, as shown in the
table. Data from performance tests of heat exchangers for a 100-kW demonstration
plant designed by Japanese investigators for the island of Nauru are also included
(Panchaletal., 1981;Hillisetal., 1979;Pandolfinietal., 1981;Mochidaetal., 1983;
Kawanoetal., 1983).
The predictions of system performance based on the results of the ANL HX
tests at the nominal conditions are presented in Table 4-21 in the columns with
"nom" in the heading. For each system design a second column is also displayed,
with "opt" in the heading. This shows the heat loading and water flow that yield the
optimal net power output per unit of heat exchanger area as estimated by use of the
analysis procedure of Owens (1983). A second column, labeled "opt2," is displayed
for the folded-tube HX design to show the power system performance when water
flows are varied to minimize C WP size. The implications of the analysis with regard
to OTEC system design are large but have not been investigated because of the
termination of program support. The results, however, demonstrate that major
improvements in power plant performance for OTEC, compared with systems
based on conventional heat exchanger designs, are possible with enhancement
techniques, improved hardware concepts, and optimization of operating condi-
tions. The data also show the significant impact of pressure losses in water ducting
on the net power output of the systems.
The ANL tests and the Japanese investigations, along with research and
development by other organizations, show that OTEC heat exchangers are practical
to construct that will have a heat transfer area requirement of between 4 and 9 m2
of heat exchanger surface per megawatt of net power developed by the power
system. For a particular design, minimum surface area per kilowatt will imply
mini mum heat exchanger cost, but area per kilowatt of net power is not a good basis
for comparing the merits of heat exchangers of different designs. Power plant cost
per kilowatt of delivered power is a better measure; however, the only valid basis
Table 4-21. OTEC power plant performance comparison
APLHX ANL-SP3 CMU Trane Japan Alfa-Laval
(nom) (opt 1) (opt 2) (nom) (opt) (nom) (opt) (nom) (opt) (nom) (opt) (nom) (opt)
Heat loading (kWt) 937 1591 570 937 1332 938 2019 938 1615 4091 4664 938 938
Water flow area (evaporator) (m2) 0.26 0.26 0.26 0.10 0.10 0.26 0.26 0.089 0.089 0.20 0.20 0.31 0.31
Water flow area (condenser) (m2) 0.26 0.26 0.26 0.14 0.14 0.26 0.26 0.089 0.089 0.20 0.20 0.31 0.31
Mass flow, warm water (kg/s) 202 202 75 202 202 202 202 202 202 409 409 202 202
Mass flow, cold water (kg/s) 202 202 30 202 202 202 202 202 202 392 392 202 202
Working fluid (WF) NH3 NH3 NH3 NH3 NH3 NH3 NH3 NH3 NH3 R-22 R-22 NH3 NH3
Mass flow, WF (kg/s) 0.76 1.28 0.46 0.76 1.09 0.77 1.66 0.78 1.35 21.47 23.50 0.77 1.81
p (sat) (kPa) 402 271 268 378 283 446 276 412 279 320 320 440 266
T (sat) (K) 15.83 10.61 9.64 14.80 10.98 17.42 10.59 15.94 10.59 10.66 9.73 17.63 10.66
T (lmtd) (evaporator) 3.27 5.55 2.75 3.52 5.01 2.26 4.86 2.51 4.32 3.82 4.35 2.48 5.02
T (lmtd) (condenser) 3.11 5.27 6.35 3.90 5.69 2.50 5.39 3.73 6.42 4.52 4.77 2.09 4.95
T in WW flow through evaporator (K) 1.16 1.97 1.90 1.16 1.65 1.16 2.50 1.16 2.00 2.50 2.85 1.16 2.75
T in CW flow through condenser (K) 1.13 1.91 4.61 1.13 1.60 1.13 2.43 1.13 1.94 2.43 2.76 1.13 2.67
U0 (evaporator) (W/m2 K) 1469 1469 1464 2844 2844 2709 2709 4030 4030 2593 2593 1956 2461
U0 (condenser) (W/m2 K) 1503 1509 644 2678 2678 3423 3423 2811 2811 1886 1886 2406 2406
Net OTEC power (kWe) 25.69 32.31 12.86 19.65 23.24 23.92 38.97 21.49 28.33 80.27 91.77 17.52 37.68
Cycle net power/max cycle power 0.825 1.000 1.000 0.891 1.000 0.683 1.000 0.817 1.000 0.994 1.000 0.663 1.000
Net power/total heat exchanger area (kWe/m2) 0.092 0.116 0.046 0.147 0.173 0.173 0.282 0.195 0.257 0.197 0.225 0.115 0.247
CW flow for 40-MWe (net) power (m3/s) 7.86 6.25 2.33 10.28 8.69 8.44 5.18 9.39 7.13 4.88 4.27 11.53 5.36
CWP diam. for 40-MWe (net) power (m) 14.15 12.61 7.71 16.18 14.87 14.66 11.49 15.47 13.47 11.15 10.43 17.13 11.68
CLOSED-CYCLE OTEC SYSTEMS 149
for heat exchanger optimization is the power cost for a total OTEC system, suitably
amortized over the life of the plant. In this selection the significant impact of the
layout and volume requirements of the heat exchanger and its associated ducting on
the total OTEC system cost must be considered. These factors are discussed in the
next section.
4.1.5.2 OTEC Power System Space Requirements
It was realized in the early design studies that the selection of shell-and-tube heat
exchangers for OTEC commercial plants would make the heat exchangers a major
volume element in the total OTEC plant installation. Thus, it was important to
investigate alternative designs that would reduce heat exchanger size per kilowatt
of net power produced. This consideration focused research and development
attention on so-called "compact" heat exchanger designs.
Estimates of the layout dimensions of 10-MWe (net) OTEC power systems
employing various heat exchanger types were made in DOE-sponsored programs
designed to identify the requirements for demonstration of OTEC commercial
capabilities. The programs were conducted in response to Public Law 96-320,
which called for the demonstration of 100 MWe of OTEC power by 1985. Power
system conceptual design studies were supported at Westinghouse (1978), Lockheed
(1981), and General Electric (1983), and a preliminary design of a power system for
baseline, barge-mounted, complete OTEC systems was prepared by JHU/APL
(George et al., 1979; George and Richards, 1980). Also, a preliminary design of a
shore-based OTEC power plant for a site at Kahe Point on the island of Oahu,
Hawaii, was prepared by Ocean Thermal Corporation (OTC) (1984) as the second
phase of a DOE cost-sharing plan to build a demonstration plant in cooperation with
the Hawaiian Electric Corporation.
The approximate volume requirements of the three 10-MWe (net) power
system modules designed in these programs, which incorporated different types of
compact heat exchangers, are compared with a module employing a conventional
shell-and-tube type exchanger in Table 4-22. The arrangement of the water ducts
significantly affects the space assigned to the machinery part of the modules. The
comparison shows that the compact designs will reduce HX volume requirements
by 55 to 70% in comparison with the shell-and-tube values, with a reduction of from
45 to 60% in total module space requirements. Proposed layouts for the four power
system types are illustrated in Figs. 6-35 and 6-36.
4.1.5.3 Other Power System Components
The principal characteristics of the major subsystems of the baseline 40-MWe
OTEC demonstration vessel are listed in Table 4-23.
Turboelectric Generators. The technology for production of vapor turbines
is highly developed and embodied in installations throughout industry and the
public utilities. Turboelectric steam generators with outputs exceeding 50 MWe in
individual units are commercially available. The technology is described in
standard references, for example, Marks' Standard Handbook for Mechanical
Engineers, 8th Ed., Baumeister, Avallone, and Baumeister, eds. Large turbines for
150 OCEAN THERMAL ENERGY CONVERSION
Table 4-22. Dimensions of alternate types of OTEC 10-MWe heat exchanger modules
Evaporator or condenser
Length Width Depth Area Volume
HX typea Designer (m) (m) (m) (m2) (m3)
S&T OTC 21.0 21.9 15.9 460 7300
PHE LMSD 10.8 13.3 14.6 145 2070
Trane Trane 23.8 9.5 14.6 225 3290
Folded tube JHU/APL 16.5 9.1 18.0 150 2700
"S&T, Ocean Thermal Corp. (1984). PHE, Lockheed (1979). Trane, Ashworth and Slabodnick (1980). Folded tube,
George and Richards (1980).
Table 4-23. OTEC power plant subsystems [40 MWe (net), 10 MWe modules]
Subsystem Approx. dimen. (m)
or component L W Z Wt (mt) Power (kW)
HX (8) 33.0 9.1 18.0 1163
Turbo-generator 10.7 4.9 3.7 102 13000
WW pump 3.8 Diam. 12.2 45
Motor & drive 3.7 2.6 6.0 20 1030
CW pump 3.5 Diam. 9.1 39
Motor & drive 3.6 2.6 6.0 25 1440
use with ammonia vapor are not in use because there has not been a demand for large
sizes. The basic design information and manufacturing technology for steam
turbines, however, are directly applicable to scale-up of ammonia turbine designs
to sizes of OTEC interest. The conceptual and preliminary design studies by
American and Japanese teams showed that several commercially available turbine
designs employing ammonia and other potential working fluids would be suitable
for OTEC. Firm quotes for the manufacture of ammonia-powered multi-megawatt
turbine-generator sets, with delivery within 12 to 18 months from receipt of an
order, were obtained in the DOE-sponsored OTEC conceptual and preliminary
design studies. Engineering designs for turbine-generator assemblies of 13-MWe
gross power were received from six organizations in 1984 in response to a request
for bids for OTC's planned installation at Kahe Point. The Ocean Thermal
Corporation preliminary design program chose the Toshiba design, which is an
axial, three-stage, double-flow type.
Liquid Ammonia Pumps. Liquid ammonia pumps with capacities in the
range from 20 to 200 kg/s are required for recycling condensate from the condenser
to the evaporator, for returning liquid from the demister or evaporator sump to the
CLOSED-CYCLE OTEC SYSTEMS 151
evaporator, and for transferring ammonia to and from storage and purification
areas. Ammonia pumps are commercially available that are suitable for these
purposes.
Electrical Power Generation and Distribution. In an OTEC system based
on the modular concept, the electrical system must be designed to combine
multiple, parallel generator outputs, for example, 10 MW (net), with appropriate
signal processing of individual unit voltages and phases to satisfy the total power
requirements. This includes power to operate water and ammonia pumps, power for
system operation and maintenance including personnel needs, and net power output
and transfer to the consumer. Provision must be made for transition to standby
diesel-generated power for essential services during shutdown or start-up opera-
tions and for transitions to and from operation with one or more units temporarily
shut down. The design must satisfy all requirements and specifications of IEEE
Standard No. 45, USCG Electrical Engineering Regulations, CG-259, ABS rules,
and appropriate standards and specifications of NEMA, IEEE, NFPA, and UL.
Commercial equipment and industrial procedures are available for these purposes.
The OTEC requirements can be met by straightforward application of electrical and
marine engineering practice.
A discussion of the electrical systems for the 40-MWe baseline moored OTEC
plant is given Section 6.5. The layout is representative of the designs prepared in
the other studies.
Biofouling Protection. Experiments with warm and cold flowing seawater,
conducted at the Natural Energy Laboratory of Hawaii (NELH) over a period of 5
years, showed that negligible biofouling of heat exchanger surfaces occurred in
operating conditions typical of OTEC condenser operation. Biofouling did build up
slowly in the evaporator operating regime; however, fouling was completely
prevented by the injection of chlorine at a concentration of 50 to 70 parts per billion
(ppb) for 1 hour per day (24-h average of 2-3 ppb) (Larsen-Basse, 1983). This
concentration is well below the level established by the Environmental Protection
Agency (EPA) as acceptable for continuous chlorine injection in power plant
operation at coastal sites. An average chlorine concentration of 2 ppb is 1% of the
minimum level typically specified for protection of public drinking water.
At an average chlorine concentration of 2 ppb, the amount needed to prevent
biofouling of the heat exchangers in a 10-MWe (net) power module would be
between 5 and 10 kg of chlorine per day. This could be supplied by shipment of
bottled liquid chlorine to the OTEC plant at monthly intervals, or a small electro-
lytic chlorine generator could be installed. In either case, the cost would be minimal.
Since chlorination is economical and convenient to use, it is the preferred
method of biofouling control; however, ultrasonic radiation (Pandolfini et al.,
1977), circulating Amertap rubber sponges, and MANN brushes have also been
shown to be effective biocontrol methods (Draley, 1981). Slurries of silica particles
of various sizes and concentrations circulated past the heat exchanger surface were
of limited effectiveness (Draley, 1981).
152 OCEAN THERMAL ENERGY CONVERSION
loads are imposed by underwater currents and shedding of vortices from the pipe.
Loads imposed during pipe deployment must also be carefully analyzed, and
designs and strategies adopted that prevent pipe damage in this critical phase of the
operation.
The following discussion is based on analytical procedures and experimental
data derived in DOE-sponsored programs conducted during the period 1975 to
1980. As shown in Fig. 4-50, many alternative concepts have been proposed
(Anderson, 1974b, 1975; Bell-Aerospace, 1979; McGuiness and Griffin, 1979).
The programs have included parametric examinations of CWP requirements for
floating OTEC plants of power ranging from 100 to 1000 MWe (Little, 1976) and
included analytic and experimental studies to provide CWP design information for
barge-mounted 40-MWe (net) OTEC demonstration vessels (George et al., 1979;
McGuiness, 1982; McHale and Bender, 1979). Design studies of cold-water pipes
for 10- and 40-MWe shore-based plants for sites in Hawaii and Puerto Rico were
made by Brewer (1979). The studies have been refined and extended as part of
conceptual and preliminary designs of a 40-MWe (nom) shore-based OTEC plant
for Hawaii by OTC (1982). Design studies of shore-based CWPs for small plants
in the 1- to 10-MW range have also been reported by Stevens (1982, 1986).
Nominal parameters for design of the 40-MWe demonstration vessel CWP
were:
Net OTEC power 40 MWe
Gross OTEC power 50-60 MWe
CWP pipe diameter 9.1m
CWP pipe length 90-1000 rn
Pipe pivoted near the center of gravity of the platform
For the demonstration program the CWP diameter was selected to represent
the maximum consistent with the use of existing construction techniques, and
facilities that could reasonably be expanded. The water flow requirement would be
met by a significantly smaller diameter, as shown in Table 4-21 (APL HX, Opt 2).
A preliminary determination of the structural requirements for an OTEC CWP
can be made from an estimate of the static loads. This estimate can be used to select
suitable materials and methods of construction and to indicate design options for
dynamic analysis and test. The final design options are then selected based on an
evaluation of construction and deployment feasibility and cost.
4.2.1.3 Static Loads
Evaluation of the static loads provides a basis for preliminary selection of materials
of construction and definition of structural details. By superposition of loads an
estimate may be made of the extreme values expected. Cylindrical vessels of steel,
aluminum, concrete, and reinforced plastics are in commercial use in diameters
exceeding 10 m. These materials and vessel construction techniques could be
adapted for CWP design (Brewer et al. 1979). The discussion to follow of the static
loads and CWP design implications is based mainly on the analysis by Little (1976).
154 OCEAN THERMAL ENERGY CONVERSION
The static forces acting on the CWP during OTEC operation are:
1. Bending moments at the joint between the CWP and the platform. For a
1000-m-long CWP of 10 m diameter, rigidly attached to the platform, the
bending moment would exceed 3 X 107 kg m if the near- surface current
attained the projected 100- year- storm value of 3.2 knots. The magnitude of the
moment shows that a pivoted connection is necessary. Bending moments also
result from subsurface currents that vary with depth. These moments may be
relieved by designing the CWP to be flexible, either by use of compliant
materials or by incorporating flexible joints between rigid pipe sections. A
pivot between the CWP and the platform is assumed in the following discus-
sion.
2. Longitudinal tension due to the weight of the pipe in seawater. This is lessened
slightly during OTEC operation by the drag force of the upward flow of cold
water through the pipe.
3. Collapse loads produced by the suction pressure in the pipe.
4. Ovalling loads caused by circumferential pressure differences.
Bending Loads. The force exerted by horizontal water flow past the CWP at
a given depth will consist of three components:
where F'd is the drag force associated with normal flow around a cylinder; Fd'', the
intermittent force produced by eddy shedding; F1 the intermittent lateral lift force
associated with changes in flow; v', the instantaneous flow velocity; and v, the
average flow velocity.
Maximum values of the forces can be estimated by assigning values of the
coefficients of:
C'd = 0.3, C''d= 0.03, Cl = 0.4 .
The maximum resulting shear force at a particular depth is then:
Since there are underwater currents that vary with depth, the values of flow
velocity used in computing shear forces and moments must be found by vector
addition at each depth of the flow velocity past the CWP due to horizontal platform
motion and to current velocity. The maximum bending loads are then found by
integration over the length of the pipe.
Longitudinal Forces. Tension in a uniform pipe caused by its submerged
weight is:
CLOSED-CYCLE OTEC SYSTEMS 155
where T is the unit stress; pP, the average density of CWP wall; p, the density of
seawater; L0, the design pipe length; and L the pipe length to depth z.
Upward force caused by internal drag on the pipe walls by flow of water is
given by:
e = pipe surface roughness factor (0.3 mm for smooth concrete, and 0.05 mm for
steel), Re = 1.7 X 106, vp = flow velocity in the CWP, D = internal diameter of the
CWP, L = CWP length."
Collapse Loads. The suction pressure difference across the CWP is the sum
of the ps caused by flow drag in the pipe, by the density difference between the
cold water and warm surface water, and by the p associated with accelerating the
cold water to the flow velocity in the pipe. Minor losses due to the inlet screens and
other restrictions in the flow must also be considered. Pumping power must also be
provided to overcome pressure losses in the heat exchangers and associated ducts.
where p0 is the density of water outside the CWP (depends on depth), vP the flow
velocity of water in the CWP, y the depth,f the friction factor = 4f', LID the length
to diameter ratio of the CWP, and p. the density of water inside the CWP.
Values of p for cold-water flow computed for values of LID and v represen-
tative of power levels of 40, 60, and 80 MWe (net) are shown in Table 4-24. The
values are based on cold-water flow of 3.4 m3/s per MWe (net), which was found
to be optimum for the 40-MWe (net) baseline design (George and Richards, 1980).
Ovalling Loads. Ovalling of the pipe can result from a circumferential
difference in pressure between the inside and outside of the pipe, which varies with
current direction and velocity. The effect is small for CWP designs of practical
interest and may be neglected.
4.2.1.4 Structural Design Options
Design of the CWP involves selection of materials and a configuration that will
have sufficient structural strength to resist the operating loads during the design life
of the pipe. The CWP must be feasible to construct and deploy at reasonable cost.
156 OCEAN THERMAL ENERGY CONVERSION
Corrosion or deterioration of the CWP wall must not produce products that could
cause corrosion or fouling of the heat exchangers. Design concepts that have been
proposed are shown schematically in Fig. 4-50.
Properties of materials that have been considered suitable for OTEC cold-
water pipe construction are summarized in Table 4-25 (Little, 1976; George et al.,
1979).
Table 4-24. Collapsing loads on CWP [cold water flow 3.4 m3/s per MWe (net)]
Power MWe (net)
40 40 60 60 80 80
V (m/s) 2.00 2.50 2.00 2.50 2.00 2.50
D(m) 9.30 8.32 11.40 10.19 13.16 11.77
L(m) 1000 1000 1000 1000 1000 1000
P (kPa)
Friction 3.53 6.16 2.88 5.03 2.50 4.36
Density effect 7.65 7.65 7.65 7.65 7.65 7.65
Dynamic loss 1.03 1.60 1.03 1.60 1.03 1.60
Miscellaneous 1.00 1.00 1.00 1.00 1.00 1.00
P(total) (kPa) 13.20 16.40 12.60 15.30 12.20 14.60
P(total) (psi) 1.90 2.40 1.80 2.20 1.80 2.10
P(800 m) (kPa) 12.50 15.20 12.00 14.30 11.70 13.70
where t is the wall thickness, E the elastic modulus, D the pipe diameter, P0 the
external water pressure, and p the internal water pressure.
Values of wall thickness computed by Eq. (4.2.6) for the structural materials
shown in Table 4-25 are listed in Table 4-26 for module sizes of 40,60, and 80 MWe
(net) for flow velocity of 2.5 m/s, and for CWP lengths of 800 and 1000 m. Data are
listed for a cold-water volume flow of 3.4 m3/s that was selected as optimum for the
40-MWe baseline OTEC demonstration plant (George and Richards, 1980).
Major reductions in the wall thickness and weight of steel, aluminum, and
glass-reinforced plastic cold-water pipes can be achieved by the use of circumfer-
CLOSED-CYCLE OTEC SYSTEMS 157
FIG. 4-50. Alternative concepts for cold-water pipe construction (McGuiness, 1979).
ential ring stiffeners. The minimum wall thickness of reinforced concrete CWPs is
limited by the requirement for 4 to 6 cm of concrete covering of the steel reinforcing
rods. Data for a range of materials, power levels, and pipe lengths are tabulated by
Little (1976).
4.2.1.5 Dynamic Loads
Deflection by Currents and Ship Forward Motions. A freely supported
CWP attached to a moored platform subjected to steady ocean currents will assume
158 OCEAN THERMAL ENERGY CONVERSION
Table 4-26. Wall thickness needed to prevent CWP buckling (flow velocity = 2.5 m/s)
CWP CWP Wall thickness (cm)
Power length diameter p
(MWe) (m) (m) (kPa) Steel Al Concrete FRPa
40 800 8.32 16.4 2.76 3.94 7.31 6.30
1000 7.13 16.1 2.35 3.35 6.23 5.37
60 800 8.74 15.0 2.82 4.02 7.45 6.42
1000 8.74 14.1 2.76 3.93 7.30 6.29
80 800 10.09 13.6 3.15 4.49 8.33 7.18
1000 10.09 14.4 3.21 4.57 8.49 7.32
"Fiberglass-reinforced plastic.
For typical cases the waves will approach the platform from one or a few
preferred directions. The function may then beconsidered as the superposition
of unidirectional functions. The 0 dependence is then eliminated.
2. If the response of the platform-CWP system to regular waves of unit amplitude
may be expressed by a response transfer function whose amplitude is R(f), then
the spectral density of the response, SR(f), to a random seaway whose spectrum
is S w (f) is given by:
3. Many statistical properties of the response can be derived from the response
function, in particular:
a. The average of the peak values of response during a period of N cycles.
b. The expected value of the largest single excursion during a large number,
N, of cycles of the response.
4. The spectral density function of Bretschneider (1959) is a valid representation
of S w (f). This formula embodies the results of a large number of sea state
measurements in a form that may be easily used for computational purposes.
160 OCEAN THERMAL ENERGY CONVERSION
There are two independent parameters: Hs, the significant wave height of the
random seaway, and f0, the frequency of waves having peak energy of the
seaway. Values of the significant wave height and mean frequency for
potential OTEC sites have been calculated by Bretschneider (1978) from
historical data on wind velocities developed in hurricanes. He has then used the
data to derive equations relating wave height to wind velocity as dependent on
geographical location.
5. The six degree-of-freedom motions of the combined system of platform and
CWP can be modeled by a quasilinear frequency-domain analysis, which uses
a finite-element model of the pipe structural dynamics and contemporary ship
or stable platform theory for the platform motions.
With this rationale, the systems of equations are formulated and solved
successively for a series of different wave frequencies, wave directions, and an
assumed unit wave magnitude. For each node the resulting complex motion vector,
xi, may be considered a frequency-dependent transfer function for that node's
motion. From the nodal motions the internal forces may be found for each element
of the continuous pipe, or the joint forces for the segmented pipe. Having the
transfer function for any response, such as platform motion, pipe nodal motion,
element stress, the response of the total system to the random seaway may be
computed.
Computer programs have been developed that solve the equations for systems
with suspended CWPs attached to a floating platform by a flexible joint. Separate
programs provide solutions as a function of pipe length, for motions and moments
of flexible pipes of specified dimensions and physical properties (ROTEC), and for
pipes made of rigid segments connected by flexible joints of given compliance
(SEGPIP). The programs include internal and external water flow (Paulling, 1979).
4.2.1.6 CWP Requirements for 40-MWe Demonstration Plants
Dynamic Analysis. The equations and programs discussed have been used
to estimate the expected stresses and displacements in the 9.1-m (30-ft) diameter
CWP designed for the demonstration plants, either grazing at a mid-Atlantic site
east of Brazil or moored at a site south of Punta Tuna, Puerto Rico.
The following significant wave heights, wave periods, and surface currents
were selected as representative for design estimates:
Two at-sea test programs, at one-sixth and one-fourth scale of the OTEC
demonstration design, and two small-scale water tunnel programs have been
conducted to measure the behavior of platform-CWP systems under conditions
CLOSED-CYCLE OTEC SYSTEMS 161
FIG. 4-51. Comparison of CWP dynamics measured in at-sea test, with analytical predictions of
Paulling computer programs (O'Connor, 1981).
CLOSED-CYCLE OTEC SYSTEMS 163
Fairly good agreement was found between the 1/20-scale-model behavior and
full-scale X-l test results; however, the predictions of full-scale motions and
stresses from extrapolation of the 1/20-scale measurements were significantly less
reliable than the predictions of full-scale behavior from the ROTEC and SEGPIP
program, using as input parameters the physical properties of the barge and CWP
and the measured environmental data.
At-Sea Test of Fiber-Reinforced Plastic (FRP) Cold-Water Pipe. With
support by the National Oceanic and Atmospheric Administration (NOAA) an at-
sea test was conducted in April and May 1983 of an 8-ft-diameter (2.44 m) FRP
cold-water pipe, 400 ft long (122 m) (Kalvaitis et al., 1983). Design, construction,
and deployment were conducted by the Hawaiian Dredging and Construction
Company. The pipe was of sandwich construction with inner and outer face sheets
0.97 cm (0.38 in.) thick separated by a 3.3-cm (1.3-in.) layer of syntactic foam. The
facing laminates were filament wound with filament strands at 60 degrees to the
longitudinal axis and with unidirectional weft-roving parallel to the pipe axis to give
an optimum balance between stiffness and strength properties.
The principal objectives of the test were to demonstrate the fabrication and
deployment of a CWP of the FRP type and to document the responses of the pipe
to the sea environment, which would provide design information for full-scale
CWPs of this type. The system characteristic frequencies are shown in Fig. 4-52
(Kalvaitis et al., 1983).
The tests included: wave height measurements and current gauge measure-
ments of the sea environment at the surface and at depth; measurement of platform
accelerations at the center of gravity in heave, sway, and surge, and yaw, roll, and
pitch; gimbal angles in roll and pitch; strain measurements at nine stations along the
pipe and accelerations at one station; and differential pressures around the pipe at
one station. An example of the average, RMS, and maximum values of the strain
measured in a test with significant wave height of 1.31 m (4.3 ft) is shown in Fig.
4-53. The observed maximum strain of 1000 microstrains corresponds to a stress
of 20.7 MPa (3000 psi) in a pipe wall with ultimate design stress of 393 MPa (57,000
psi).
Review and analysis of the test results and comparison of measured and
predicted pipe and barge responses were conducted by Vega and Nihaus (1985)
under NOAA support. General conclusions from the test and data analysis were:
1. The pipe response was dominated by the bending strains induced by barge
motions coupling with the pipe, and was large enough to be important for
design.
2. No evidence was found for vortex-excited vibrations, heave-induced axial
strains, or torsional oscillations.
3. There was general agreement between the measured system responses and the
predictions of the NOAA/ROTEC frequency-domain model. The predicted
response of a barge as characterized by response amplitude operators agreed
with the observed behavior within the limits of the measurement uncertainties.
The response of the pipe as determined by the lengthwise distribution of
standard distribution strain was underestimated by the model program. The
164 OCEAN THERMAL ENERGY CONVERSION
FIG. 4-52. OTEC system characteristic frequencies in at-sea operation (Kalvaitis et al., 1983).
high-end values from the range of predicted standard deviation strains were
10-20% less than the standard-deviation strains derived from measurements.
4. It was determined that the predictions were sensitive to the values assumed for
the added mass and drag coefficients, indicating that a range of values should
be selected for predictions. The values giving the highest response used in
determining the standard deviation should be used to predict operational and
extreme weather effects. The relationship between peak value and standard
deviation should be used to estimate maximum stresses for a given number of
cycles.
4.2.1.7 General Conclusions Regarding Suspended Cold-Water Pipes
The analytical and experimental studies discussed have established a firm engineer-
ing basis for the construction of OTEC cold-water pipes up to 10 m in diameter.
Important points include:
1. Methods of construction have been demonstrated for cold-water pipes of 2.5
m (FRP) and 3 m (lightweight concrete) in diameter, which are directly
applicable to fabrication of CWPs with diameters up to 10 m or more.
2. At-sea tests have demonstrated that analytical models can predict dynamic
behavior and pipe stresses with sufficient accuracy to give high confidence of
pipe survivability under extreme 100-year-storm conditions.
3. Lightweight concrete and FRP have been shown to be suitable CWP construc-
tion materials.
4. More accurate data are desirable on added mass and drag associated with lateral
CLOSED-CYCLE OTEC SYSTEMS 165
FIG. 4-53. Observed strains in at-sea test of FRP CWP (Kalvaitis et al., 1983).
electric power plants that discharge effluents through large underwater pipes
extending to considerable depths and distances from shore.
Design studies of cold-water pipes, including a review of materials options and
installation methods for 10- and 40-MWe shore-based plants for sites in Hawaii and
Puerto Rico, were made by Brewer (1979). Facilities and materials for construction
of pipes of concrete, steel, fiber-reinforced plastic (FRP), and elastomeric materi-
als, were investigated. It was concluded that land-based plants of 10 to 40 MWe in
size were feasible. The near-shore installation could be done with existing technol-
ogy. Emplacement of the deep-water section of the pipe would require development
of new techniques and facilities. This would require new development involving
reasonable extension of demonstrated technology. The work led to recommenda-
tion of reinforced concrete as the lowest-cost material for construction and
deployment at the Hawaii site where the sea bottom was relatively smooth. It was
concluded that the irregular sea bottom at the Puerto Rico site would require a
buoyant pipe using a catenary support anchored with piles driven into the sea floor.
For this design FRP, although considerably more expensive than concrete, would
be the preferred option. Concrete and FRP pipes in diameters exceeding 50 ft have
been constructed for use as storage vessels and in off-shore platform structures and
have been made with existing facilities. Pipe dimensions and materials for the two
plant sizes and locations are listed in Table 4-27.
Similar studies have been conducted for sites at Punta Yeguas, Puerto Rico (40
MWe) (Moak et al., 1981); at Taiwan [8.7 MWe (net)] (Lin et al. 1983); at Tahiti
(5 MWe) (Vilain et al., 1985); at Jamaica (1 MWe) (Berndt and Hogbom, 1983),
and at the island of Bali (100 kW) (Bart, 1983). Design studies of CWPs for small
FIG. 4-54. Typical off-shore profile for island-based OTEC plant (Brewer, 1979).
CLOSED-CYCLE OTEC SYSTEMS 167
Table 4-27. CWP dimensions for shore-based OTEC plants of 10.0 and 40.0 MWe (net)
power
Hawaii Puerto Rico
10.0 MWe (net) 40.0 MWe (net) 10.0 MWe (net) 40.0 MWe (net)
ID (m) 6.80 7.50 7.61 10.05
Wall thickness (cm) 34.3 45.7 3.8-11" 3.8-11a
Length (m) 2440.0 2440.0 2440.0 2440.0
Material concrete concrete FRP FRP
plants in the 0.07- to 2-5-MWe range have also been reported by Stevens (1982).
After review of previous work and consideration of factors affecting deploy-
ment costs, the French team involved in the design of a 5-MWe plant for the island
of Tahiti selected an FRP pipe construction as the preferred design for a new
deployment and emplacement method that would avoid the problems associated
with the topography of the sea bottom at potential OTEC sites. The method,
indicated in Fig. 4-55 (Vilain et al, 1985), involves two steps:
1. A series of anchoring fixtures are mounted on the sea bed at intervals along the
pipe trajectory, to which cables supported by floats are attached. The anchors
may be held in place by dead weights or by piles driven into the sea bottom. To
each cable a sleeve (hawse) is attached at a depth determined by the pipe
trajectory.
2. The flexible, slightly buoyant FRP pipe is assembled on shore and deployed by
drawing it through the hawses. It is then attached to the end of the shelf-
mounted pipe, which extends from the onshore plant through the surf zone to
a suitable point near the edge of the shelf.
The most comprehensive studies of the design requirements for shore-based
cold-water pipes were made in the preliminary design of a 50-MWe OTEC plant
planned for operation at Kahe Point, Hawaii (Ocean Thermal Corp., 1984). That
work led to a final pipe configuration in two segments with total length of 3667 m
(12,030 ft). The near-shore segment would extend 935m from the inlet of the OTEC
plant, approximately 485 m off shore, to the edge of the shelf at 1410m from shore.
This section would be made of post-tensioned concrete and would be integral with
two similar ducts carrying the mixed effluent from the plant to a discharge point at
the edge of the shelf. The final section, extending from the shelf to a depth of 670
m, would be made of FRP segments with bellows joints at alternating intervals of
75 and 91 m along the 2560-m length of the deep-water section of the pipe. Details
of the pipe construction and deployment are presented in Section 6.4 in connection
with the complete plant design. It is worth noting that the final cost of the pipe,
including deployment, was estimated to be 47% of the total system construction
cost of $327 million.
From the preceding discussion, the follow conclusions regarding CWPs for
168 OCEAN THERMAL ENERGY CONVERSION
FIG. 4-55. Deployment method proposed for FRP CWP at Tahiti (Vilain et al., 1985).
4.3.1 Electrolysis
In water electrolysis gaseous hydrogen and oxygen are produced, which store the
electricity in the form of internal chemical energy. Because electrolysis does not
involve a thermal cycle, Carnot's equation does not apply and, ideally, 100%
conversion of electrical to chemical energy can occur. In practice, values of 80 to
90% can be achieved; therefore, hydrogen production is a highly efficient way to
store electrical energy on grazing OTEC ships. The OTEC hydrogen gas may be
liquefied and shipped to world ports or it may be used on board for the manufacture
of methanol, of current interest as a replacement for gasoline and diesel fuel, or
170 OCEAN THERMAL ENERGY CONVERSION
ammonia, a storable, high-octane-number fuel that would produce only water and
nitrogen as combustion products.
Major commercial interest in water electrolysis developed after 1920 in
connection with world demands for ammonia fertilizers that could be produced
economically using low-cost hydroelectric power to supply hydrogen. Develop-
ment stopped in the 1940s when natural gas became a lower-cost source of
hydrogen for ammonia synthesis. Apprehension about potential depletion of fossil
fuel supplies and environmental concerns caused a renewal of research and
development in the 1970s that showed that significant improvements in electrolyzer
performance were possible compared with the early designs; however, the low cost
of hydrogen produced from natural gas has continued to make electrolytic hydrogen
noncompetitive for ammonia synthesis and has inhibited growth of a demand for
large electrolyzers.
Electrolyzers are designated as unipolar or bipolar. In the unipolar design, a
voltage is applied between a positive metal electrode and a negative metal electrode
that are suspended in a vessel containing an electrolyte. Hydrogen is evolved at one
electrode (the cathode) and oxygen at the other (the anode). A suitable barrier
directs the gases into separate ducts. A single cell may hold many electrodes, all of
the same polarity being connected in parallel. Thus, a unipolar cell is characterized
by low voltage and high current, large size, and simplicity of design.
In bipolar cells the electrodes are formed by depositing or pressing a thin
coating of conducting material onto opposite sides of thin sheets of porous material
containing the electrolyte. With appropriate packaging each sheet can become an
electrolyzer cell, and cells may be assembled in stacks that are held together by tie-
bolts, as in a filter press. The positive electrode of one cell is connected to the
negative electrode of the next (i.e., in series). Bipolar systems are compact and
compatible with voltage and current loadings typical of power generation equip-
ment; however, special electrode-separator constructions and leak-proof gaskets
are required that pose problems of reliability, durability, and cost. A concise
discussion of the electrochemical and manufacturing status of unipolar and bipolar
electrolyzers is presented in LeRoy (1983). A comprehensive review of industrial
equipment for water electrolysis is given in Tilak et al., 1981).
Water electrolyzers are commercially available from several manufacturers;
however, scale-up and further development are required to provide units of 2- to
5-MWe capacity suitable for OTEC.
4.3.1.1 Electrolyzer, Inc., Unipolar Electrolyzer
The principal developer and supplier of unipolar electrolyzers since the 1940s has
been Electrolyzer, Inc., of Canada (Crawford and Benzima, 1986). The electrolyte
is concentrated KOH. Development was slow for 3 decades, but in recent years
improvements in the cell design have been achieved that boost performance and
reduce cost (LeRoy, 1983). Durable surface coatings for the electrodes have been
developed that significantly reduce the cell voltage required, as shown in Fig. 4-56.
The data provide evidence that electrolyzer efficiency above 85% will be attainable
in commercial models. Improvements have also been made in cell resistance and
CLOSED-CYCLE OTEC SYSTEMS 171
FIG. 4-56. Voltage profiles for improved Electrolyzer, Inc., electrolysis cells (Crawford and Benzima,
1986).
FIG. 4-57. Layout of 35-MWe Electrolyzer, Inc., hydrogen plant (Crawford and Benziraa, 1986).
GE, and New York electric power producers to support the development of large
units for energy storage and advanced energy systems (Nuttall, 1981). Further
impetus for development of large units was provided by the OTEC program, which
proposed tests of a 40-MWe baseline plantship as a prelude to larger commercial
vessels.
The SPE electrolyzer uses as the electrolyte a sulfonated fluorocarbon plastic
film (Nafion), approximately 1/4 mm thick, which conducts electricity when
saturated with water. Electrodes are formed by bonding a thin platinum coating on
opposite sides of the film. When a voltage is applied, hydrogen ions pass through
the film releasing hydrogen gas at the surface. Electrons are taken from hydroxyl
ions at the opposite surface to generate oxygen gas. Since the solid electrolyte is
stable and fixed in position, only pure water needs to be supplied for elcctrolyzer
operation. Individual cells are pressed together in a bipolar arrangement with
suitable separators to form a complete electrolyzer consisting of 50 to 200 cells.
Since the cells are in series, the voltage across a stack of plates is the product of cell
CLOSED-CYCLE OTEC SYSTEMS 173
voltage times the number of cells. When the electrolyzer operates, water is
protonically pumped through the Nafion film at a rate about 8 times the electrolysis
rate. The water provides the source of hydrogen and oxygen, as well as cooling to
remove heat generated by the ohmic resistance of the Nafion film.
Initial SPE development focused on electrolysis modules comprising 60 cells
with Nafion sheets of 1/4 m2 area. At 10,000 A/m2 the design power input was 275
kW. An example of average cell performance is shown in Fig. 4-58, and the
proposed layout of a 4-MWe module is shown in Fig. 4-59. The floor area is 42 m2,
and headroom of 2.7 m is indicated (Nuttall, 1981).
Experiments were conducted with cell area of 1 m2, which showed the
feasibility of scale-up to this size, but problems with gaskets were encountered that
had not been eliminated when funding support was withdrawn after 1980 as a result
of low fossil fuel prices and the change of DOE administration. It is believed that
the emergence of a large demand for electrolytic hydrogen would lead to rapid
commercialization of this technology.
4.3.1.3 Teledyne Energy Systems' Alkaline-Electrolyte Electrolyzer
For the past 2 decades the Teledyne Energy Systems has been a commercial supplier
of bipolar electrolysis cells that use a concentrated solution of potassium hydroxide
as the electrolyte (Kincaide, 1979; Kincaide and Murray, 1981). The commercial
units supply a steady industrial demand for packaged electrolyzers that deliver 50-
200 standard liters per minute of pure hydrogen. Input power ranges from 10 to 40
kW. Similar systems are also commercially available from several foreign manu-
facturers: Brown-Boveri (Switzerland), Norsk-Hydro (Norway); and French and
Belgian suppliers.
The basic design of these electrolyzers is similar to that of the SPE type of GE.
Thin sheets of asbestos of 0.1 m2 area, saturated with KOH, are used as separators
instead of the Nafion film; concentrated KOH solution is circulated instead of pure
water for electrolysis and to remove heat. Teledyne was funded in parallel with the
FIG. 4-59. Layout of 4-MWe module of GE SPE electrolyzer system (Nuttall, 1981).
FIG. 4-60. Performance improvements through research and development of Teledyne Energy
Systems electrolyzer (Kincaide and Murray, 1981).
FIG. 4-61. Schematic of Claude hydrogen liquefaction process (Perry and Green, 1984).
also pioneered the development of this cycle.) The ideal work to liquefy hydrogen
is 4.0 kW h/kg. For plants in the kilowatt range the actual requirement is about 25
kW h/kg; at power inputs above 1 MW the requirement is estimated to be 15 kW
h/kg. Thus, energy required for hydrogen liquefaction, at a 1-MWe power level,
adds 27% to that needed for electrolysis.
After liquefaction the hydrogen flows through insulated lines to storage
vessels of Dewar construction that are designed to hold approximately 1 month's
output from the liquefaction plant. The design requirements and practical construc-
tion of the transfer and storage equipment have been established in operation of the
Kennedy Space Center and other sites, and are directly applicable to OTEC design
needs (Loyd, 1986). For a 160-MWe OTEC plant a single storage vessel of
approximately 40 m diameter, or four vessels of 20 m diameter, would be required.
The engineering requirements of transfer lines for liquid hydrogen are discussed by
Jones etal. (1983).
The practical problems caused by the low density of liquid hydrogen and the
need for cryogenic equipment and procedures make this method of OTEC energy
transfer not attractive for near-term applications, unless a large demand should arise
for liquid hydrogen per se for space-shuttle or aerospace-plane applications.
fuel for nonpolluting internal combustion engines (the octane number is 111). With
this fuel only water and nitrogen gas are produced as exhaust products. Thus, OTEC
ammonia could play a major role in supplying future world needs for a practical fuel
that would not contribute to global warming in either its manufacture or its use. The
use of OTEC ammonia as an energy transfer medium was proposed in 1975 (Olsen
and Pandolfini, 1975). Preliminary design of a 40-MWe OTEC plantship was
reported in 1980 (George and Richards, 1980).
The heat of combustion of ammonia based on the hydrogen content is 88% of
that of molecular hydrogen, but the density is 0.60 kg/liter compared with 0.071 of
liquid hydrogen, and the boiling point is -33.4C rather than 258C. The heat of
combustion per liter is 11.2 MJ versus 8.58 MJ for liquid hydrogen. At 20C the
vapor pressure is 10 atm. These properties combine to make ammonia production
an efficient and practical way to store OTEC energy for periodic transport at normal
temperatures and reasonable pressure for later use on land.
Ammonia is an important industrial chemical that is produced commercially
by steam reforming of methane to supply the hydrogen. In this process nitrogen is
prepared either by air liquefaction and distillation or by burning hydrogen in air in
a closed vessel to convert the oxygen to water, which is then removed by
condensation. The two gases are then combined in a catalytic reactor to form
ammonia. For OTEC ammonia manufacture the reactor and distillation plant
equipment of the commercial ammonia from natural gas plants are directly
applicable. The costly steam-reforming subsystem is eliminated.
The basic reactions in the commercial process are:
1.77 H 2 0+0.88 C H 4 = 0.88 C0 2 +3.53H,
0.53 H2 + air (0.266 O2 + N2) = 0.53 H20 + N2
N2 + 3H2 = 2NH 3
Thus, 0.44 mole of CO2 is formed for each mole of ammonia, or 1.3 kg of CO2 per
kgofNH 3 . 2
Ammonia is the primary source material for fertilizers containing nitrogen,
which have a major role in international food production. Over 125 million metric
tons of ammonia are produced per year worldwide for this and other uses. In
consequence, facilities are available worldwide for liquid ammonia storage and
transport: in tank cars, trucks, and pipelines, and in ammonia tankers (the liquid is
cooled to 33.4C to allow storage at atmospheric pressure). OTEC ammonia
production would be able to use these facilities as soon as commercial operation
began, avoiding the slow and costly development of the infrastructure that would
be required for liquid hydrogen use as an energy carrier (Avery, 1988).
Preliminary design details of a 40-MWe OTEC baseline ammonia demonstra-
tion plantship are presented in Section 6.5.1.
Primary aluminum production by electrolysis in the United States in 1989 was four
million metric tons and consumed approximately 66 billion kilowatt hours of
electric power (Aluminum Association of America, 1989). This is equivalent to
2.6% of the U.S. output of the electric power plants in that year. The low bus-bar
cost of OTEC electric power suggests examination of the potential economic
benefits of using this source of electricity for aluminum refining. A study of the
process requirements, siting options, estimated costs, and projected financial
returns was made for several alternative scenarios, including on-board aluminum
plants and onshore installations receiving electrical power from dedicated OTEC
plants moored offshore. The results were compared with data for a baseline plant
using the conventional Hall process, built and operated onshore at a Gulf of Mexico
site, that would purchase power from a public utility company. Floating OTEC
aluminum plantships and shore-based plants using the Hall process were found to
CLOSED-CYCLE OTEC SYSTEMS 179
1. The need for durability under repeated flexing of the "riser cable" that would
carry power from the OTEC power plant to a firm support on the sea floor or
on a submerged buoy supported at a depth low enough to be free from waves
and water currents. For plants moored within approximately 15 km of shore,
single cables could carry alternating current directly from the OTEC plant to
the shore installation. Longer distances would require cables designed for
direct current that would involve a bottom-laid cable connected at a junction
box to a riser cable of different construction. Methods of predicting loading and
bending stresses were developed (Lindman and Constantino, 1981). Two cable
designs were identified as candidates for OTEC application: a self-contained,
oil-filled design with paper insulation (SCOF) and a type using cross-linked
polyethylene as insulation (XLPE). Both types were tested in a special facility
designed by Simplex Wire and Cable Co. and operated using facilities
provided by Hydro Quebec Institute de Recherche (Kurt, 1981). The construc-
tion of the two cable types is shown in Fig. 4-62. In the tests the cables were
subjected to repeated cycles of bending and tension under varying loads to
90,000 kg while immersed in seawater in a tank that could simulate water
depths to 1800 m (6000 ft). The water temperature was controlled at an average
value that would be experienced by a riser cable installation at the Puerto Rico
site. Voltage of 200 kV was applied during the test with current flow adjusted
to bring the internal temperature to the maximum value predicted for the test
regime.
Sample cables of the two types were subjected to six different testing
regimes lasting 1 month representing conditions that could be encountered in
moored OTEC operation including 100-year-storm sea states. The tests indi-
cated that cables of the XLPE design would meet requirements for 30-year life
under OTEC moored-plant conditions and could be used in water depths over
200 m (Soden et al., 1981).
2. Development of a method for protection of the section of the cable from the
anchor position on the seabed at a depth of 1200 m or more to the shore
installation. Experience has shown that the cable must be placed in a trench to
provide adequate protection. A survey showed that one commercial trenching
system (Scarab II of Ocean Search, Inc.) was available that could operate at a
maximum depth of 1840 m. A second (Sea Plow IV of AT&T) had a depth
capability of 914 m. Both would require operational modifications for OTEC
use. Extension of the capabilities to satisfy OTEC requirements appears to be
feasible (Nunn, 1981).
3. Identification and development of equipment and procedures for deploying
and servicing the system. Alternative riser cable systems that could be used
with barge or spar OTEC plants moored at Puerto Rico were evaluated, as
shown in Fig. 4-63 (Pieroni et al., 1979). The use of a stand-off submerged buoy
arrangement that routes the riser cable from the OTEC plant to the buoy and
then to the seabed is favored (Schultz and Dalton, 1981). Design details are
presented for a gimballed attachment of the cable to the ship, for disconnect
hardware, and for the anchor assembly on the sea bottom. Deployment
equipment and costs are also discussed.
CLOSED-CYCLE OTEC SYSTEMS 181
FIG. 4-62. Cable construction for underwater power transmission (Kurt, 1981).
FIG. 4-63. Proposed deployment arrangement for OTEC power cables (Pieroni et al., 1979).
182 OCEAN THERMAL ENERGY CONVERSION
This concept is a variant on the method of energy transfer that uses OTEC to
produce a fuel that is transported to a land installation where it is used to generate
electricity, preferably by fuel cells.
The electrochemical-bridge system stores OTEC energy electrochemically,
transfers the product to shore by ship, then generates electric power on shore by
reversing the shipboard process. Two processes were investigated: a redox battery
system and a lithium-water-air battery system (Biederman, 1978). The author
compares the estimated costs of the electrochemical method with other alternatives,
including production of hydrogen or ammonia and transfer of molten salts.
The redox battery is a device containing electrodes immersed in an electrolyte
containing a salt that can exist in two ionic states, such as ferrous or ferric chloride.
Application of a voltage above the ionization potential of the lower state causes
migration of the ions to the anode where Fe3+ ions are converted to Fe2+ ions, with
release of an electron to the external circuit. The redox process allows energy to be
stored in the electrolyte, which may then be shipped to shore where the reverse
process can deliver energy to a user. Quantitative evaluation of the system indicates
that the shipping cost of the dilute solution would be too high to make the system
of commercial interest.
In the lithium-air-battery process a slurry of lithium hydroxide produced at an
onshore plant is transported to an OTEC ship, where OTEC electric power is used
electrolytically to convert the slurry to billets of metallic lithium. The lithium is then
shipped back to the onshore plant where the lithium becomes the anode of a lithium-
air-battery assembly in which concentrated lithium hydroxide is the electrolyte.
The battery generates electric power, in the process converting the metallic lithium
to lithium hydroxide. Cooling the electrolyte causes lithium hydroxide to precipi-
tate. The precipitate is mixed with water to form a pumpable slurry, which is then
returned by ship to the OTEC vessel where the cycle is repeated. The concept has
been examined on a small scale and could be economically attractive if the design
assumptions were verified in commercial development. The overall efficiency of
electric power transfer by this method was estimated to be in the range of 60%
(Biederman, 1978).
The need for an underwater cable is avoided by siting the OTEC plant on land or
on the continental shelf in shallow water. In this case warm and cold water are
conveyed to the plant through bottom-anchored ducts with inlets at appropriate
depths. This method allows the cold water to be used for other purposes after
flowing through the heat exchangers. Production of fresh water, use of the cold
water for air conditioning, and mariculture are all potential benefits. Where the
power demand is large and deep cold water is available only far from shore, moored
CLOSED-CYCLE OTEC SYSTEMS 183
plants stationed at the edge of the continental shelf will be favored. It was estimated
that up to 15 GWe of power for southern states in the United States could be
produced in this way by OTEC plants sited near the edge of the continental shelf in
the Gulf of Mexico. At small tropical-island sites where cold and warm water are
available close to shore, power demand is small, but requirements for fresh water
and opportunities for profitable mariculture exist. Shore-based OTEC plants will be
favored for these installations. The OTEC power from either type of installation
could be used for fuel production via water electrolysis, as discussed previously.
4.4.1 Grazing
OTEC plantships in normal operation will graze at an average speed of 0.4-0.5 knot
and a maximum speed of 1.0 knot on the tropical oceans, changing position from
day to day to keep the plantship in a region of optimal surface temperature. The
propulsion system must also be able to maintain ship heading and stability in waves
and winds of the severity predicted for the 100-year storm. Because the forward
speed is so low, maneuverability must be achieved by varying the thrust angle of
the propulsion system; therefore, the design incorporates rotatable thrusters mounted
below the hull at the four corners of the platform. With this arrangement thrust can
be oriented as needed to maintain heading in crosscurrents and to counteract the
effects of beam seas.
An estimate of the power requirements for OTEC plantships can be made with
standard marine engineering procedures based on the geometry of the platform and
cold-water pipe. Propulsion equipment (thrusters and controls) of the required
performance is commercially available; however, estimates require detailed data
on the dependence of drag coefficients (Cd) on grazing speed as affected by winds
and waves. The estimated error is in the range of 15 to 25% (SNAME, 1980).
The propulsion requirements for the 40-MWe OTEC ammonia plantship were
determined in the baseline design study (George and Richards, 1980). A value of
Cd = 1 was selected for the platform and Cd = 0.7 for the cold-water pipe. The
pertinent parameters of the cruising rectangular barge was:
Bow width (W) = 43 m
Length (L) = 135 m
Draft (normal operation) (Dn = 20 m
Draft (off-loaded) (Dt) = Urn
CWP(OD) = 9.9m "
CWP (length) = 915m
Velocity (calm water) = 0.51 rn/s (1 knot)
Velocity (normal operation) = 0.2 m/s (0.4 knot)
For the maximum cruising speed in calm water the drag is 98,800 kgf.
184 OCEAN THERMAL ENERGY CONVERSION
4.4.2 Position Control for Direct Power Transmission from Floating OTEC
Plants
Direct transmission of OTEC power to shore requires that floating OTEC plants be
maintained at a fixed location by mooring or dynamic positioning. Both procedures
have been considered. Engineering design data and equipment can be based on the
extensive technology developed in the off-shore oil industry.
4.4.2 A Stationkceping
Power transmission from a floating OTEC plant imposes two conditions not
encountered in commercial marine engineering practice. A stationkeeping system
CLOSED-CYCLE OTEC SYSTEMS 185
must be designed to hold the plant within a small circle above the selected
geographical position without interfering with the power cable, in water depths
exceeding 1000 m. It must also ensure that the platform can be oriented to withstand
waves and currents generated in storms of once-in-100-years severity. Mooring
and/or dynamic positioning may be used. The requirements and potential designs
have been the subject of several investigations.
A general study of OTEC stationkeeping requirements was made in 1976 and
1977 using systems studies from the DOE OTEC program as a source of design data
(Davidson and Little, 1978). The study includes assessment of the requirements,
equipment options, and costs of stationkeeping systems. Mooring systems and
dynamic positioning systems using thrusters, effluent vectoring, and combinations
of the two were evaluated. Figures 4-64 to 4-70 are drawn from the report.
Characteristics of platform configurations and estimated drag coefficients are given
in Fig. 4-64. Marine engineering experience and design information acquired in
OTEC plant design studies were used to derive a baseline relationship between
OTEC plant displacement and net power output, P(net):
Displacement (mt)/P(net) (MWe) = 3210P(net) 018 . (4.4.1)
This equation was used to estimate the stationkeeping loads for OTEC plant
configurations ranging in power from 10 to 1000 MWe. Two model environmental
situations were selected for evaluation:
1. A moderate environment with surface current of 1.5 m/s.
2. An extreme environment with surface current of 3 m/s.
Drag forces computed for the two environments, which are based on the drag
coefficients shown in Fig. 4-64, gave the values shown in Fig. 4-65 for the range
of plant powers and configuration types. The shaded areas bounded by the lines
labelled "semi-submersible" and "spar" include the ranges for the other platform
types. The power requirements for position control are shown in Fig. 4-66.
An estimate of mooring system relative performances and costs showed that
moorings could be designed, using state-of-the-art technology, for OTEC power
plants as large as 1000 MWe that would have an estimated cost for the extreme
environment ranging from about $1000/kW for plants in the 10-MWe range to
about $100/kW for the 1000-MWe size (1978 dollars). For a 200-MWe plant, the
study predicts a mooring cost of about $200/kW (Davidson and Little, 1978). The
data in Chapter 7 show that the estimated mooring system costs would be about 8%
of the total plant cost at the 200-MWe power level.
Types of thrusters applicable to OTEC position control are illustrated in Fig.
4-67. As shown in Fig. 4-68, a survey indicated that the delivered thrust of available
units ranged from 125 to 225 N/kW (12.5 to 22.5 kgf/kW). For the evaluation study
a thruster type designed to produce a thrust of 190 N/kW was chosen as a baseline.
With these guidelines the dynamic positioning requirements, without effluent
thrust control, were estimated as shown in Fig. 4-68. The corresponding costs are
presented in Fig. 4-69.
186 OCEAN THERMAL ENERGY CONVERSION
FIG. 4-64. Dependence of drag coefficients on design for alternative OTEC configurations (Davidson
and Little, 1978).
FIG. 4-65. Drag force versus displacement for OTEC system alternatives (Davidson and Little, 1978).
FIG. 4-66. Power requirements for position control (Davidson and Little, 1978).
188 OCEAN THERMAL ENERGY CONVERSION
FIG. 4-67. Thruster types available for OTEC position control (Davidson and Little, 1978).
cost of these units was estimated as $0.8/N in the APL baseline barge design. Thus
total costs of dynamic positioning equipment that would provide sufficient thrust
to ensure survival in extreme storm conditions would be about $280 per kilowatt of
OTEC plant power, or roughly 40% higher than mooring costs.
Subsequent to the Davidson and Little study, two detailed evaluations of the
stationkeeping requirements of 40-MWe OTEC power plants that would be
emplaced either on a barge of the APL baseline design or on a spar were made with
DOE support by Lockheed (1979) and M. Rosenblatt & Son (MRS) (1980). A
variety of possible systems were studied, and the two most promising designs were
identified for each platform type. Designs and costs of 10- and 40-MWe spar plants
were also developed by Scott (1979). General reviews were published by Wood and
Price (1980) and Ross and Wood (198 1). An evaluation of mooring requirements
and options was also published by Homma and Kamogawa (1979).
CLOSED-CYCLE OTEC SYSTEMS 189
FIG, 4-68. Estimated cost of thrusters for OTEC position control (Davidson and Little, 1978).
Examples of mooring concepts from the Lockheed and MRS studies are
shown in Fig. 4-71. In both studies barge and spar platforms were considered. The
preferred barge mooring concepts were basically the same, that is, a multileg moor
made of chain segments attached to drag embedment anchors at the bottom with
wire rope for the intermediate sections. The MRS design brings the wire rope to line
handling machinery on the platform. The Lockheed design uses a chain section for
the line handling on the platform. The Lockheed design uses a chain section for the
line handling on the platform. For the spar configuration both multi-anchor-leg
(MAL) mooring and tension-anchor-leg (TAL) concepts were investigated. In the
latter scheme the CWP is designed to incorporate tensile elements that can
withstand the tension loads.
190 OCEAN THERMAL ENERGY CONVERSION
FIG. 4-69. Estimated cost of OTEC position control using thrusters (Davidson and Little, 1978).
FIG. 4-70. OTEC position control combining mooring and thrusters (Davidson and Little, 1978).
CLOSED-CYCLE OTEC SYSTEMS 191
FIG. 4-71. Alternative mooring arrangements for OTEC systems (Wood and Price, 1980).
The mooring procedure for the TAL design involves the following steps
(Wood and Price, 1980):
1. A deadweight anchor with buoyant cables attached is floated to the mooring
site, lowered to the sea bottom, and filled with concrete or secured by piles
driven into the sea floor.
2. The spar platform is positioned over the anchor and ballasted to lower it until
the bottom link of the CWP can be attached to the anchor.
3. The spar platform is then deballasted, raising the spar to the operational
submergence level.
The TAL concept has several attractive features:
1. The system eliminates the need for onboard anchor-line handling equipment.
2. The simplicity implies minimal operating problems.
3. It can be employed in shallower water than multileg arrangements.
4. It could simplify power cable problems.
5. Life-cycle costs could be lower.
There are two serious disadvantages that were not resolved when the program
was terminated:
1. The security of the system is totally dependent on the integrity of the single
tension leg, which includes the anchor, the connection to the end of the cold-
water pipe, the internal tension member in the CWP, and the universal joint at
the top of the CWP. Failure of any one could lead to catastrophic failure of the
entire system.
192 OCEAN THERMAL ENERGY CONVERSION
4.5 PLATFORM
The term OTEC platform is used here to denote the structure that houses and
supports the systems involved in ocean thermal energy conversion, storage, and
transfer. It may take many forms depending on size, site, purpose, and subsystems
designs. A basic distinction may be made between floating platforms and fixed
installations constructed onshore or bottom-mounted in shallow water near the
shore. Engineering studies have shown that the design and constuction can use
technology already well developed in the shipbuilding and offshore oil industries
such as Deep Oil Technology (Brewer, 1979), Gibbs and Cox, Inc. (Scott and
Rogalski, 1978), M. Rosenblatt & Son, Inc. (Basar et al., 1979), Gilbert/Common-
wealth (Bartone, Jr., 1978), and Mitre Corp. (Roberts, 1977). Some modifications
or extensions of U.S. facilities would be necessary. A vigorous OTEC program
could revitalize the U.S. shipbuilding industry.
(Castellano and van Summern, 1978), and JHU/APL (George and Blevins, 1978).
The configurations selected are shown in Fig. 1-11 (Waid, 1978).
The primary conclusion of the study was that all of the configurations studied
could be constructed in existing U.S. shipyardsone Atlantic, two Pacificusing
either concrete or steel. Facility modifications would be minor; however, for
configurations involving draft of more than 28.3 m (80 ft) (spar types), a sheltered
deep-water site would be required. Three suitable sites in the U.S. were identified:
Puget Sound in Washington, Honolulu Harbor, and Lahaina Roadstead in Hawaii.
(Shipyards throughout the world equipped for construction of super tankers and
offshore platforms would also be suitable. A listing is presented in Chapter 6.)
For the specific requirements of OTEC, post-tensioned concrete is the favored
material for the hull. The cost of construction would be lower than for steel; concrete
is durable in seawater without the need for surface protection; concrete is compat-
ible with the use of aluminum heat exchangers. The greater weight and volume of
the hull are not a disadvantage because hull drag is not significant at the grazing
speed of 0.4 knot, and added weight is necessary, even with the concrete hull, to
compensate for the buoyancy of the heat exchangers. The attractiveness of concrete
construction for the OTEC barge design was demonstrated in the low-cost con-
struction and deployment of the ARCO barge in 1976 shown in Fig. 6-2. This ves-
sel, 133 m long and 35 m wide with 20 m draft, was constructed in 28 months
from the contract date (Mast, 1975; Anderson, 1977). The design studies for this
vessel, backed by successful construction experience, formed the basis for the 137
m X 43 m X 27 m deep platform of the 40-MWe OTEC baseline, which is fully
described in Chapter 6 (George and Richards, 1980).
To minimize cold-water pipe motions the CWP-platform joint should be
located at the center of gravity of the platform, or if more than one pipe is employed,
at the longitudinal center of rotation. This requirement and the hull penetrations
required for the heat exchangers make it necessary to provide large wing walls at
the sides of the platform to meet requirements for longitudinal strength.
Although the platform size and construction requirements are within normal
shipbuilding and oil platform technology, the combination of platform and cold-
water pipe introduces new features that require evaluation and optimization. Of
primary importance is the supporting structure for the cold-water pipe, which must
accommodate angular motions up to about 20, must incorporate a seawater seal,
and must be compatible with the proposed method of installing the CWP.
30 rotation. In the plane of the gimbal a spherical shell formed the top of the pipe.
A cylindrical cap with a flat ring of nylon and Teflon provided a sliding seal between
the cold water in the pipe and the surrounding platform structure. A diagram of the
assembly, without the sealing equipment, is shown in Fig. 4-72. Operation of the
structure was satisfactory during the 5-month at-sea test period, including an
occasion when a combination of mooring loads, strong currents, and high seas
caused the pipe angle at the platform to reach the design limit of 30. Impact of the
pipe with one of the stops caused minor damage to that structure but did not interfere
with the scheduled testing. To prevent further damage the ship was released from
the mooring and allowed to drift with the current. On release of the platform from
the mooring the pipe angle decreased to 10. This experience confirms the predicted
advantage of the grazing mode in minimizing CWP support problems.
Advantages Disadvantages
FIG. 4-73. Types of flexible joints studied for OTIiC CWP support (TRW, 1979).
196 OCEAN THERMAL ENERGY CONVERSION
Only the ball-and-socket joint allows freedom of rotation about the vertical
axis, which is desirable to avoid torques associated with platform slewing motions;
however, analysis showed that the loads would not be excessive for the universal
joint. The design concept of the universal joint assembly to support a 9.1 -m FRP
CWP is shown in Fig. 4-74. The study indicates that optimum design of CWP-
platform combinations based on FRP pipes will favor use of cold-water pipes
supported at the platform by a universal joint at the center of rotation. A spherical
shell segment with the same geometrical center in contact on its outer surface with
a ring seal attached to the platform prevents water leakage. The ring seal would be
made of replaceable segments. The concept envisions construction of the CWP on
shore as a single 9- to 10-m-diameter tube that would be floated to the platform,
upended, and inserted from below into the attachment assembly. The concept
would be applicable to platforms employing CWP designs of diameters larger than
10-15 m if OTEC development in the future should indicate their desirability.
4.5.3.2 Support Structure for Segmented CWP
An independent preliminary design of a CWP-platform joint was made as part of
the baseline design by JHU/APL of a 40-MWe OTEC pilot plant. The concept
involves use of a jointed CWP of lightweight concrete that is assembled by
successively connecting and lowering 15-m pipe segments through the opening in
I-'IG. 4-74. Diagram of universal join! for OTF.C FRP cold-water pipe (TRW, 1979).
CLOSED-CYCLE OTEC SYSTEMS 197
the platform. This requires a joint design that allows the pipe to be supported at the
joint during the assembly process. After consideration of gimbal and universal joint
designs, the ball-and-socket configuration shown in Fig. 4-75 was selected as
optimum for this design, because existing technology could be extended with low
risk to accommodate both manufacturing and deployment requirements (George
and Richards, 1980). An alternate to the design of Fig. 4-75 was subsequently
proposed that would employ an inner ball supported by external bearing pads, as
shown in Fig. 4-76. This design is preferred because it simplifies problems of
fabrication. The large-diameter shell section of Fig. 4-75 would be more difficult
to machine and install, without distortion, in the ship structure.
To demonstrate feasibility of the lightweight concrete jointed pipe design, a
3.0-m- (10-ft-) diameter, 1/3-scale pipe, consisting of two pipe sections joined by
the planned flexible joint, was constructed and tested (O'Connor, 1980, 1981).
Figure 6-4 shows a drawing of the assembly. The joint was tested to failure by
applying increasing lateral and longitudinal loads to the two pipe sections. Failure
FIG. 4-75. Ball-and-socket design tor 40-MWe OTEC CWP support (George and Richards, 1980).
198 OCEAN THERMAL ENERGY CONVERSION
FIG. 4-76. Alternative design of ball-and-socket support for 40-MWe OTEC CWP (George and
Richards, 1980).
occurred at a load 140% of the design value, based on the loads predicted for the
most severe 100-year storm in the equatorial Atlantic Ocean.
Construction of this first-of-a-kind test article at the Concrete Technology
commercial facility, using existing equipment, was completed within the planned
time and cost and without need for modification of the initial design specifications.
The test provided a firm basis for concluding that the jointed CWP made of
lightweight concrete would be feasible to construct and would meet operational
requirements. Existing handling equipment would be compatible with the planned
procedures for deploying the rigid pipe sections.
CLOSED-CYCLE OTEC SYSTEMS 199
Both flexible and j ointed C WP designs would require platform space along the
centerline with an outside diameter of approximately 25 m (80 ft) to support and
allow movement of the 9.1-m CWP through an 18 angle.
4.5.3.3 Support Structure for Stockade-Pipe CWP
A third alternative for the CWP-platform joint was proposed by Anderson for
support of his novel stockade CWP design (Anderson, 1976). In this concept the
pipe is supported by cables connected to an air spring that is designed to have a
natural frequency roughly half the minimum wave exciting frequency. This
prevents the pipe from resonating with the waves. Thus the pipe remains relatively
stationary during the heave motions of the platform. Details of the design and of a
later version involving servo control have not been published.
General layouts of OTEC systems on floating platforms were included in the studies
discussed previously; however, only the JHU/APL 40-MWe baseline study of
moored and grazing OTEC plants included preliminary engineering of the platform
(a concrete barge) and details of the structures that would be needed to accommo-
date all of the subsystems, arranged to form a first approximation to an optimum
total system. The design represented a team effort under overall direction of JHU/
APL (George and Richards, 1980) including contributions from AB AM Engineers,
Inc.; L. R. Glostenand Associates, Inc.; Tokola Offshore, Inc.; Sew ard Associates;
and J. R. Paulling, Inc. This baseline information is suitable for determining weights
and dimensions of the components of total OTEC systems, for quantitative
estimates of dimensional requirements of larger-scale commercial-size floating
OTEC plants and plantships, and for preliminary estimates of system costs.
The dimensions and layout of the 40-MWe baseline barge designed to
demonstrate either ammonia OTEC plantship operation or direct power transfer to
shore from a moored plant are presented in Section 6.5 (George and Richards,
1980). The baseline design provides data for scale-up of OTEC vessels to sizes
above 300 MWe, by considering a 40- to 60-MWe power assembly as a modular
unit for larger plants (Richards et al., 1980). Conceptual layouts of ammonia
plantships of 40,60,120, and 360 MWe (net) capacity, from this article, are shown
in Fig. 4-77. It should be noted that area per megawatt decreases from 145 m2 (1550
ft2) for the 40-MWe size, to 107 m2 (1150 ft2) per megawatt for the 360-MWe size.
This implies a significant reduction in cost per megawatt for the larger plant sizes.
Further reductions would be expected through optimization of the cold-water flow
and incorporation of more compact heat exchangers of the plate type, as discussed
in Section 4.2. These considerations suggest selection of a maximum diameter of
about 10 m as being optimum, which would imply scale-up in modules of
approximately 80 MWe (nom). Detailed designs have not been made.
The dimensions (Z vertical) and weights of the principal subsystems included
in the integrated 40-MWe grazing plant were estimated as shown in Table 4-23
(George and Richards, 1980). These components would be typical of power plant
200 OCEAN THERMAL ENERGY CONVERSION
FIG. 4-77. Layouts of OTEC ammonia plantships of various power outputs (Richards et al., 1980).
designs for both floating and stationary systems employing compact 10-MWe
modules.
The dimensions of heat exchanger subsystems proposed for OTEC by several
contractors are listed in Table 4-22. The advantages of compact HX types compare
with the S&T type are evident from the table.
range of 10 MWe, and the opportunity to combine OTEC power generation with
mariculture, fresh-water production, and use of the cold water for air conditioning,
leads to plant layouts that will be ramified and site specific. Water pumping power
will be substantially increased if the plant is placed on the shore at a height above
storm-wave limits. Preliminary layouts for plants proposed for Hawaii, Nauru, and
Tahiti are summarized in Section 6.4.
NOTES
1. The diagram represents the values of the parameters for the nominal 40-MWe OTEC
power cycle discussed in Section 4.1.3.
2. If nitrogen is produced by air liquefaction and distillation, the estimated electrical
energy required for the process is 34.3 MJ per kg of nitrogen produced (Perry and
Green, 1984). If the energy is supplied by a coal-burning power plant that requires
10,000 kJ per kW h of power produced, approximately 10 kg of CO2 will be formed
per kg of N2 produced.
3. This would not occur with properly ballasted cold-water pipes.
REFERENCES
Afgan, N. H., and E. U. Schlunder, 1974. Heat exchangers: Design and theory source, book.
Washington, D.C.: Scripta.
Aluminum Association of America, 1988. Aluminum production and power consumption.
Anderson, A. R., 1977. "World's largest prestressed LPG vessel." J. Prestressed Concrete
Institute, 22, 1.
Anderson, J. H., 1974a. "Ocean thermal energy." 2nd Ocean Thermal Energy Conversion
Conf. and Workshop Proc., Washington, D.C., Sept.
, 1974b. "Progress report on a working model of a closed cycle plant." 2nd Ocean
Thermal Energy Conversion Conf. and Workshop Proc., Washington, D.C., Sept., 55.
, 1975. "The Andersons' operating model of the ocean thermal energy conversion
principle." Proc. 3rd Workshop on Ocean Thermal Energy Conversion, Houston, Tex.,
May, IX.
, 1976. "Design of cold water pipe for sea thermal power plants." Sea Solar Power, Inc.,
York, Pa., COO-2961-2.
, 1978. "A compact heat exchanger concept for ocean thermal power plants." Proc. 5th
Ocean Thermal Energy Conversion Conf., Miami Beach, Fla., February, 6, VI-321.
, 1986. Sea solar power business plan. Sea Solar Power, Inc., York, Pa.
, and J. H. Anderson, Jr., 1977. "Compact heat exchangers for sea thermal power
plants." Proc. 4th Annual Conf. on Ocean Thermal Energy Conversion, New Orleans,
La., March, 6, 3.
, T. D. Dellinger, D. H. Forney, and R. S. Lyman, 1980. "The SSP compact heat
exchangertest results." Proc. 7th Ocean Energy Conf., Washington, D.C., June, 1,
7.4.
, and P. B. Pribis, 1979. "Compact heat exchanger design progress." Proc. 6th OTEC
Conf., Washington, D.C., 1, 1 1.4.
ASHRAE, 1977, 1985. ASHRAE handbook and product directory fundamentals. Society of
Naval Architects and Marine Engineers, New York.
Ashworth, D. J., and G. Slebodnick, 1980. "Cost and configuration of a closed-cycle OTEC
power system using bra/.ed aluminum plate-and-fin heat exchangers." Conf. Proc. 7th
Ocean Energy Conf., Washington, D.C., June, 1 & 2, 7.1.
202 OCEAN THERMAL ENERGY CONVERSION
Avery, W. H., 1988. "A role for ammonia in the hydrogen economy." Int. J. of Hydrogen
Energy 13, 761.
, D. Richards, and G. L. Dugger, 1985. "Hydrogen generation by OTEC electrolysis,
and economical energy transfer to world markets via ammonia and methanol." Int. J. of
Hydrogen Energy, 11, 727.
, D. Richards, W. G. Niemeyer, and J. D. Shoemaker, 1983. "OTEC energy via
methanol production." Proc. Intersociety Energy Conversion Conf., Orlando, Fla.,
August, 1, 346.
Bakstad, P. J., and R. O. Pearson, 1979. "Design of a 10-MWe (net) OTEC power module
using vertical, falling-film heat exchangers." Proc. 6th OTEC Conf., Washington, D.C.,
June, 8.2-1.
Barr, R. A., P. Y. Chang, andC.Thasanatorn, 1978. "Methods for and examples of dynamic
load and stress analysis of OTEC cold weather pipe designs." Hydronautics, Inc., Nov.
Bart, J. G., 1983. "OTEC activities by the Netherlands." Proc. Oceans '83, Aug. 2, 716.
Bartone, Jr.,L. M., 1978. "Alternative power systems for ex trading energy from the ocean:
A comparison of three concepts." Proc. 5th Ocean Thermal Energy Conf., Miami
Beach, Fla.,3, VII-68-108.
Basar, N. S., 1978. "OTEC ocean systems evaluation." Proc. 5th Ocean Thermal Energy
Conversion Conf., Miami Beach, Fla., 2, IV-15.
, J. C. Daidola, and R. C. Sheffield, 1979. "Station keeping subsystem designs for
modular experiment OTEC plants." Proc. 6th OTEC Conf., Washington, D.C., 1, 5.8-
1.
Baumeister, T., E. A. Avallone, and T. Baumeister III Marks' standard handbook for
mechanical engineers, 8th Ed., New York: McGraw-Hill, p. 9.
Berenson, P. J., 1962. "Experiments on pool-boiling heat transfers." /. Heat Mass Transfer
5, 985.
Bergles, A. E., and M. K. Jensen, 1977. "Enhanced single-phase heat transfer for OTEC
systems." Proc. 4th Annual Conf. on Ocean Thermal Energy Conversion, New Orleans,
La., March, 6, VI-41.
Berndt, T., and J. W. Connell, 1978. "Plate heat exchangers for OTEC." Proc. 5th Ocean
Thermal Energy Conversion, Miami Beach, Fla., Feb., 6, VI-288.
,andT.Hogbom, 1983."The 1-MWe OTEC pilot plant in Jamaica." Proc. Oceans '83,
718.
Biederman, N. P., 1978. "Chemical, electrochemical and thermal bridges for transmission
of OTEC power." Proc. 5th Ocean Thermal Energy Conversion Conf., Miami Beach,
Fla., 2, 94.
Blevins, R. W., H. L. Donnelly, and J. T., Stadter, 1980. Verification test for cold water pipe
analysis. Johns Hopkins Univ. Applied Physics Lab., SR-80-2A,B,C, Oct.
Bretschneider, C. L., 1959. Wave variability and wave spectra for wind generated and
gravity waves. Beach Erosion Board, TM 118.
, 1978. "Operational sea state and design wave criteria for potential OTEC sites." Proc.
5th Ocean Thermal Energy Conversion Conf., 2, IV-178.
Brewer, J. H., 1979. "Land-based OTEC plantscold water pipe concepts." Proc. 6th OTEC
Conf., Washington, D.C., 1, 5.10-1.
Castellano, C., and J. van Summcrn, 1978. "OTEC-1 early ocean test project." Proc. 5th
Ocean Thermal Energy Conversion Conf., Miami Beach, Fla., 1, IV-128.
Chang, P. Y., 1977. Structural analysis of cold water pipes for ocean thermal energy
conversion power plants. Hydronautics, Inc., May.
Chun, K. R., and R. A. Seban, 1971. "Heat transfer to evaporating liquid films." /. Heat
Transfer, Trans. ASME, Series.
CLOSED-CYCLE OTEC SYSTEMS 203
Hawaiian Dredging and Construction Company, 1983. CWP at-sea test article. TRW
Defense and Space Systems Group. Internal report.
Hillis, D. L., J. J. Lorenz, D. T. Yung, and N. F. Sather, 1979. OTECperformance tests of
the Union Carbide sprayed-bundle evaporator. Argonne National Lab., May, ANL/
OTEC-PS-3.
Holman, J. P., 199\. Heat transfer. New York: McGraw-Hill.
Homma, T., and H. Kamogawa, 1979. "An overview of Japanese OTEC development."
Proc. 6th OTEC Conf., Washington, D.C., 1, 3.3.
Hoshide, R. K., A. Klein, et ah, 1983. OTEC-1 test operations experience final report.
Energy Technology Engineering Center, Energy Systems Group, Rockwell Interna-
tional, ETEC-82-19.
Jones, M. S., 1979. "Integration issues of OTEC technology to the American aluminum
industry." Proc. 6th OTEC Conf., Washington, D.C., 1, 10.9-1.
, V. Thiagarahan, and K. Sathjanarayna, 1981. "OTEC aluminum integration studies."
Proc. 8th Ocean Energy Conf., Washington, D.C., 1, 643.
Kajikawa, T., T. Agawa, H. Takazawa, M. Amano, K. Nishiyama, and T. Homma, 1979.
"Studies on OTEC power system characteristics and enhanced heat transfer perfor-
mance." Proc. 6th OTEC Conf., Washington, D.C., June, II, 11.5.
, M. Takazawa, and M. Mizuki, 1983. "Heat transfer performance of metal fiber sintered
surfaces." Heat Transfer Eng., 4, 57.
-, H. Takazawa, H. Nishiyama, T. Agawa, H. lidaka, and M. Amano, 1980. "Develop-
ment of enhancement of the working fluid side heat transfer for OTEC." Conf. Proc. 7th
Ocean Energy Conf. Washington, D.C. Sept., 1 & 2, 12.2.
Kalvaitis, A. N., F. A. McHale, and L. A. Vega, 1983. "At-sea test of a large-scale OTEC
pipe." Proc. Oceans '83, Aug., 2, 734.
Kawano, S.,T. Takahata, and M.Miyoshi, 1983. "Performance tests of a condenser for a 100-
kW (gross) OTEC plant." Proc. ASME-JSME Thermal Eng. Joint Conference, Hono-
lulu, March, 2, 247.
Keirsey, J. L., J. A. Funk, P. P. Pandolfini, and R. T. Cusick, 1979. "Core unit testing of the
JHU/APL shell-less folded tube heat exchanger." Proc. 6th OTEC Conf., Washington,
D.C., June, II, 11.2
Kincaide, W. C., 1979. "Large alkaline electrolysis systems for OTEC." Proc. 6th OTEC
Conf., Washington, D.C., 2, 10.8-1.
, and J. N. Murray, 1981. "Advanced alkaline electrolysis systems for OTEC." Proc. 8th
Ocean Energy Conf., Washington, D.C., 1, 685.
Kirkbride, C. G., 1934. "Heat transfer by condensing vapors on vertical tubes." Trans.
AICHE,30, 170.
Kurt, J. R., 1981. "Testing of OTEC riser cable components and models." Proc. 8th Ocean
Energy Conversion Conf., Washington, D.C., 2, 595.
Lachmann, B. A. P., 1978. "European OTEC project." Proc. 5th Ocean Thermal Energy
Conversion Conf., Miami Beach, Fla., 11-174.
Larsen-Basse, J., 1983. "Effect of biofouling and countermeasures on heat transfer in surface
and deep ocean Hawaiian watersEarly results from the seacoast test facility." Proc.
ASME-JSME Thermal Eng. Joint Conf., Honolulu, March, 2, 285.
Lavi, A., 1974. "Heat exchangers and optimum design for solar sea power plants." 2nd
Ocean Thermal Energy Conversion Conf. and Workshop Proc., Washington, D.C.,
Sept., 101.
LcRoy, R. L., 1983. "Industrial water electrolysis: Present and future." Int. J. Hydrogen
Energy 8, 401.
CLOSED-CYCLE OTEC SYSTEMS 205
Lewis, L. G., and N. F. Sather, 1979. OTEC performance texts of the Carnegie-Mellon
University vertical fluted-tube condenser. Argonne National Lab., May, ANL/OTEC-
PS-4.
, and Sather, N. F., 1978. OTEC performance tests of the Union Carbide flooded-bundle
evaporator. Argonne National Lab., Dec. ANL/OTEC-PS-1.
Lin, G. W., T. T. Lee, and K. K. Hwang, 1983. "Ocean thermal energy conversion technology
development program in Taiwan, Republic of China." Proc. Oceans '83, Aug., 2, 723.
Lindman, R., and R. W. Constantino, 1981. "Methods of predicting loading and bending in
an OTEC riser cable." Proc. 8th Ocean Energy Conf., Washington, D.C., 2, 587.
Little, T. E., J. D. Marks, and K. Ft. Wellman, 1976. Deep water pipe, pump, and mooring
study: Ocean thermal energv conversion program final report. Westinghouse Electric
Corp., ERDA/COO-2642-3.
Lockheed, 1979. Preliminary design report for OTEC station-keeping (SKSS). Lockheed
Missiles and Space Co.
, 1979. PSD-II final design briefing. Lockheed Missiles and Space Co., Task 2.
Lorenz, J. J., C. B. Panchal, and G. E. Layton, 1982. An assessment of heat-transfer
correlations for turbulent water flow through a pipe at Prandtl No.s. 6.0 and 11.6.
Argonne National Lab., ANL/OTEC-PS-11.
, andD. Yung, 1978. "Combined boiling and evaporation of liquid films on horizontal
tubes." Proc. 5th Ocean Thermal Energy Conversion Conf., Miami Beach, Fla., Feb.,
6, 46.
, and D. T. Yung, 1980. "An evaluation of the cost-effectiveness of surface enhance-
ments for OTEC heat exchangers." Conf. Proc. 7th Ocean Energy Conf., Washington,
D.C., June, 1 & 2, 12.3.
D. T. Yung, D. L. Hillis, and N. F. Sather, 1979. OTEC performance tests of the
Carnegie-Mellon University vertical fluted-tube evaporator. Argonne National Lab.,
July, ANL/OTEC-PS-5.
Loyd, C., 1986, "Hydrogen production processes and facilities." Hydrogen Technology
Conf. Proc., NASA Lewis Research Center.
Mailen, G.S., 1980. "Experimental studies of OTEC heat transfer evaporation of ammonia
on vertical smooth and fluted tubes." Conf. Proc. 7th Ocean Energy Conf., Washington,
D.C., June, 2, 12.5-1.
Marchand, P., 1980. Le Energie Thermique des Met: IFREMER, 1.
, 1981. "Travaux francais sur 1'energie thermique des mers." La Houille Blanche, 4/5,
315.
1985. "French thermal energy conversion program." Proc. French-Japanese Symp.
on Ocean Development, Tokyo, Sept., 1.
Mast, R. F., 1975. "The ARCO LPG vessel." Conf. on Concrete Floating Ships and Terminal
Vessels, 1.
McGuiness, T., 1982. "Some ocean engineering considerations in the design of OTEC
plants." Proc. IECEC '82 J7th Intel-society Engineering Conf., 3, 1423.
, and A. Griffin, 1979. "Preliminary designs of OTEC cold water pipes for barge and
spar-type OTEC plants." Proc. 6th OTEC Conf., 1, 6.1-1.
McHale, F., and M. Bender, 1979. "Construction and deployment of an operational OTEC
plant at Kona, HI." Proc. 11th Annual Offshore Technology Conf., 3, 1661.
, 1984a. OTEC CWP at-sea test program phase II final report. Hawaiian Dredging and
Construction Co.
, 1984b. OTEC.'cold water pipe at-sea test program final report phase II suspended pipe
test. Hawaiian Dredging and Construction Co.
206 OCEAN THERMAL ENERGY CONVERSION
Miyoshi, R., T. Takahata, and H. Mochida, 1977. "Condensation heat transfer of Freon-11."
Proc. 14th Heat Transfer Symposium (in Japanese).
Moak, K. E., G. M. Hagerman, and J. T. Wu, 1981. "Design and integration of a 40-MWe
OTEC shelf-mounted pilot plant." Proc. 8th Ocean Energy Conf., Washington, D.C.,
June, 2, 133.
Mochida, Y., T. Takahata, and M. Miyoshi, 1983. "Performance tests of an evaporator for
a 100-kW (gross) OTEC plant." Proc. ASME-JSME Thermal Eng. Joint Conf., Hono-
lulu, March, 2, 241.
Mortaloni, L. R., 1983. CWP at-sea test article. TRW Internal Report, Hawaiian Dredging
and Construction Co.
Nunn, G. N., 1981. "OTEC subsea electrical power cable protection systems and technol-
ogy." Proc. 8th Ocean Energy Conf., Washington, D.C., 2, 625.
Nuttall,L.J., 1981. "Advanced water electrolysis technology for efficient utilization of ocean
thermal energy." Proc. 8th Ocean Energy Conf., Washington, D.C., 2, 679.
Ocean Thermal Corporation, 1982. Ocean thermal energy (OTEC) pilot plant conceptual
design study. Ocean Thermal Corp.
, 1984. OTEC preliminary design engineering. Ocean Thermal Corp., 2.2.1.
O'Connor, J. S., 1979. Lightweight concrete development program, phase I. Johns Hopkins
Univ. Applied Physics Lab., SR-79-1.
, 1981. Lightweight concrete cold water pipe tests phase II. Johns Hopkins Univ.
Applied Physics Lab. , SR 80-5A.
Olsen, H. L., and P. P. Pandolfini, 19~i'5. Analytical study of two-phase-flow heat exchangers
for OTEC systems. Johns Hopkins Univ. Applied Physics Lab., AEO-75-37.
Otteman, L. G., R. C. Crooke, and R. Shoemaker, 1985. "Offshore oil and gas technology
assessment." Proc. Oceans '85, 4.
Owens, W. L., 1978. "Correlation of thin film evaporation heat transfer coefficient for
horizontal tubes." Proc. 5th Ocean Thermal Energy Conversion Conf., Miami Beach,
Fla.,Feb., 6, 71.
, 1979. "OTEC system response and control analy sis." Proc. 6th OTEC Conf. June, 8.8-
1.
, 1983. "Optimization of closed-cycle OTEC plants." Proc. ASME-JSME Thermal Eng.
Joint Conf., Honolulu, March, 2, 227.
-, and L. C. Trimble, 1980. "Mini-OTEC operational results." Conf. Proc. 7th Ocean
Energy Conf., Washington, D.C., June, 2, 14.1-1.
Panchal, C. B., 1984. "Heat transfer with phase change in plate-fin heat exchangers." Proc.
22nd ASME-AICHE National Heat Transfer Conf., Niagara Falls, N.Y., August.
, D. Hillis, L. Seren, D. Yung, J. Lorenz, A. Thomas, and N. Sather, 1981. "Heat
exchanger tests at Argonne National Laboratory." Proc. 8th Ocean Energy Conf.,
Washington, D.C., June.
-, D. L. Hillis, and A. Thomas, 1983. "Convective boiling of ammonia and Freon 22 in
plate heat exchangers." Proc. ASME-JSME Thermal Eng. Joint Conf., Honolulu,
March, 2, 261.
Pandolfini, P. P., W. H. Avery, and J. Jones, 1977. "Effect of biofouling and cleaning on the
external heat transfer of large diameter tubes." OTEC Biofouling and Corrosion Conf.,
Battelle Seattle Research Center, Seattle, Wash., Oct.
, G. L. Dugger, F. K. Hill, and W. H. Avery, 1980. "ALCLAD-aluminum, folded-tube
heat exchangers for OTEC." Proc. 3rd Miami International Conf. on Alternative
Energy Sources, Miami Beach, Fla., Dec.
-CLOSED-CYCLE OTEC SYSTEMS 207
Schultz, J. A., T. C. Dalton, and R. Eaton, "Developmental design status of riser cable
systems for OTEC pilot plants." Proc. 8th Ocean Energv Con/, Washington, D.C., 2,
607.
Scott, R. J., 1979. "Conceptual designs and costs of OTEC 10-40-MWe spar platforms."
Proc. 6th OTEC Conf., Washington, D.C., 1, 5.6-1.
, and W. W. Rogalski, 1978. "Considerations in selection of OTEC platform size and
configuration." Proc. 5th Ocean Thermal Energy Conversion Conf., Miami Beach, Fla.
2, IV-77.
SNAME, 1980. Society of Naval Architects and Marine Engineers, New York.
Snyder, III, J. E., 1976. Energy utilization aboard OTEC platforms. Ocean and Energy
Systems.
Soden, J. E., D. O. Libby, and J. R. Spiller, 1981. "A study of ocean cableships applied to
submarine power cable installation." Proc. 8th Ocean Energy Conf., Washington, D.C.,
2,617.
, R. Eaton, and J. P. Walsh, 1982. "Progress in the development and testing of OTEC
riser cables." Oceans '82 Conf. Records, Marine Tech. Soc., Washington, D.C., E, 587.
Stevens, H.C., 1982. "ANL research and development programs at the seacoast test facility."
Proc. Marine Technology Workshop, Washington, D.C., Sept., 56.
, 1986. "Updated conceptual design of a 10-MW shore-based OTEC plant." Proc.
Energy Sources Technology Conf. and Exhibition, New Orleans, Feb.
Stevens Institute, 1975. Hydrogen storage and transfer. Stevens Institute of Technology,
AD-AO16 25.
Suematsu, H., 1974. "Condensation heat transfer on fluted tubes." Proc. Kakagu Kokaku 8th
Shuki (in Japanese), 402.
Takazawa, H., K. Nishiyama, and T. Kajikawa, 1983. "Condensing heat transfer enhance-
ment on vertical spiral double fin tubes with drainage gutters." Proc. ASME-JSME
Thermal Engineering Joint Conf., 269.
Thomas A., D. Hillis, C. B. Panchal, J. J. Lorenz, D. Yung, and N. D. Sather, 1980.
"Experimental tests of 1-MWt OTEC heat exchangers at Argonne National Labora-
tory." Conf. Proc. 7th Ocean Energy Conf., Washington, D.C., June, 2, 12.1-1.
, J. J. Lorenz, and D. L. Hillis, 1979. "Performance tests of the 1-MWt shell-and-tube heat
exchangers for OTEC." Proc. 6th OTEC Conf., Washington, D.C., June, 2, 11.1-1.
Tilak, P. W., T. W. Lu, J. E. Colman, and S. Srinivasan, 1981. "Electrolytic production of
hydrogen." in Comprehensive treatise of electrochemistry, Vol. 2, New York: Plenum
Press.
TRW, 1979. Ocean thermal energy conversion cold water pipe preliminary design project
final report. TRW Energy Systems Group.
, 1982. Ocean thermal energy conversion (OTEC) three-dimensional design methodol-
ogy. TRW Defense and Space Systems Group. Vol. 1, Technical manual, Vol. 2, User's
manual.
Uehara, H., H. Kusuda, M. Monde, T. Nakaoka, and H. Sumitomo, 1983. "Shell-and-plate
type heat exchangers for an OTEC plant." Proc. ASME-JSME Thermal Eng. Joint Conf.,
Honolulu, March, 2, 253.
, K. Masutani, and M. Miyoshi, 1978. "Heat transfer coefficients of condensation on
vertical fluted tubes." Proc. 5th Ocean Thermal Energy Conversion Conf., Miami
Beach, Feb., 6, 146.
Vachon, R. I., G. H. Nix, and G. E. Tanger, 1968. "Evaluation of constants for the Rohsenow
pool-boiling correlation.' ./. Heal Transfer, May, 239.
CLOSED-CYCLE OTEC SYSTEMS 209
Vega, L. A., and G. C. Nihaus, 1985. OTEC cold water pipe al-sea test program data
analysis project, comparisons between measured and predicted barge and pipe re-
sponse: Evaluation of the NOAA/ROTECF and NOAA/TRW computer models. Vega
and Associates, Honolulu, HI.
Vilain, R. H.,M. A. Spielrein, and J. P. Elcano, 1985. "Structure and material for the CWP
for OTEC Tahiti experimental plant." Proc. Ocean Engineering and the Environment
(Oceans '85), San Diego, Nov., 2, 1217.
Waid, R. L., 1978. "OTEC platform design optimization." Proc. 5th Ocean Thermal Energy
Conversion Conf., Miami Beach, Fla., 2, IV 1-15.
Webb, R. L., 1978. "A generalized procedure for the design and optimization of fluted
Gregorig condensing surfaces." Proc. 5th Ocean Thermal Energy Conversion Conf.,
Miami Beach, Fla., Feb, 6, 123.
Westinghouse, 1978. Ocean thermal energy power system development phase IPSD-I final
report. Westinghouse Electric Corp. Power Gen. Div.
Wood, W. A.,andD. Price, 1980. "The design of stationkeeping subsystems for OTEC pilot
plants." Conf. Proc. 7th Ocean Energy Conf., 1, 3.4-1.
Wright, D., W. Wagner, J. Shoji, and J. Campbell, 1978. "Summary of analysis and testing
on advanced Variflux OTEC scaled evaporators and condenser components." Proc. 5th
Ocean Thermal Energy Conversion Conf., Miami Beach, Fla., 6, 345.
Wu, C., 1987. "A performance bound for real OTEC heat engines." Ocean Engineering, 14,
349.
Yung, D. T., D. L. Hillis, J. J. Lorenz, and N. F. Sather, 1979. OTEC performance tests of
the Union Carbide enhanced-tube condenser. Argonne National Lab., ANL/OTEC-PS-
2.
, J. J. Lorenz, D. L. Hillis, and C. B. Panchal, 1981. OTEC performance tests of the Johns
Hopkins University Applied Physics Laboratory folded-tube heat exchanger. Argonne
National Lab., ANL/OTEC-PS-9.
Zener, C., and A. Lavi, 1973. "Drainage systems for condensation." Prof. Solar Sea Power
Plant Conf. and Workshop, Carnegie-Mellon University, Pittsburgh, July, 60.
5
OPEN-CYCLE OTEC
flow rate of (1 x) m at state 3,. is pumped back to the ocean at state 7, where its
temperature is lower than the inlet warm seawater temperature. This temperature
difference is the "flashdown" of a flash evaporator. The turbine exhaust at state 4
is condensed by giving up heat to the cold seawater and ends up at state 5 as saturated
condensate before it is pumped back to the surroundings at state 6. The condensate
in a surface condenser is fresh water, which can be utilized as a by-product of an
open-cycle OTEC power plant. If the condensate is put back into the ocean, it will
eventually be mixed with the seawater and travel along the process path from states
6 and 7 to state 1 through a natural convection mechanism originated from the
absorption of solar thermal energy by the earth's atmosphere and the oceans.
The system temperature and mass flow rate distribution in the open cycle
consisting of the flash evaporator, turbine/generator, and surface condenser is
shown in Fig. 5-3.
Neglecting the small sensible heat effect in the steam production and combin-
ing the energy and mass balances in the flash evaporator, turbine, and surface
condenser gives the rates of heal transfer and power production in the basic open-
cycle OTEC system in the following equations:
OPEN-CYCLE OTEC 213
where mH is the warm water mass now rate, THis the warm-water inlet temperature,
TW is the warm-water exit temperature; TC is the steam condensing temperature; Cp
is the specific heat; Qin is the rate of heat transfer to the system; Qout is the rate of
heat removal from the system; is the efficiency of the system; T is the turbine
efficiency; Pn is the net power; P i is the gross power; and PCWS Pwsw, and Pinisc are
the parasitic power loss in cold- and warm-water loops and miscellaneous equip-
ment, respectively.
The principal disadvantages of the open-cycle OTEC system are the low Ap
available to operate the turbine, 2.8 kPa (0.15 psi) compared with 270 kPa (49 psi)
for the closed-cycle system using ammonia working fluid, and the large specific
volumes that must be used by the steam turbine. A low cycle efficiency due to the
small temperature difference combined with the large specific volumes requires a
very large turbine. So far, no full-scale turbines for plants 1 MW and greater have
been designed and operated. A further disadvantage of open-cycle operation is the
need to provide vacuum pumps to remove fixed gases that are removed from the
214 OCEAN THERMAL ENERGY CONVERSION
seawater along with the steam that forms the working fluid to drive the turbine. If
allowed to accumulate in the condenser, these fixed gases would rapidly degrade
the operation of the condenser. The power needed to operate the vacuum pumps can
significantly reduce the net power output.
On the other hand, for a given temperature difference, the open-cycle OTEC
system is thermodynamically superior to the closed-cycle system because a larger
portion of the temperature difference between the hot and the cold water is available
to produce net power. The reason is that in the direct-contact heat transfer mode of
the evaporator and condenser used in the open-cycle system, the steam in the
vacuum chamber can approach the temperature of the warm-water discharge from
the evaporator (Kreith and Bharathan, 1987). At the same time, the exhaust steam
from the turbine can be condensed at a temperature approaching the condenser exit
temperature of the cold water from the deep ocean. In the closed-cycle system, the
working fluid passing through the turbine is separated from the warm and cold
waters of the ocean by a solid wall. Hence, in both the evaporator and the condenser,
a first temperature drop is necessary to transfer the heat from the ocean water
through the wall to produce the vapor in the boiler, and then another temperature
drop is required to condense the vapor of the working fluid at the outlet from the
turbine by cold seawater. Consequently, the heat exchangers for closed-cycle
OTEC plants require very large surface areas to minimize the thermodynamically
required temperature losses. These exchange surfaces are continuously exposed to
corrosion and biofouling in the ocean environment. A large fraction of the heat
exchanger cost is saved if the Claude process is used. Moreover, in the open cycle
one need not consider the possible loss of volatile or hazardous working fluids. A
supporting reason for building OTEC power plants with open-cycle power genera-
tors (Hagen, 1975) is the additional use of cold water for fish farming. However, all
OTEC designs make use of massive amounts of cold deep ocean water; therefore,
no one design possesses any significant advantage over any other with respect to
mariculture considerations.
An analytical model of the power cycle and seawater supply systems for an OC
OTEC power plant that allows ready examination of the effects of system and
component operating points on plant size and parasitic power requirements has
been developed by Parsons et al. (1984, 1985). Johnson (1978) derived a formula
to compute the maximum amount of work that can be extracted from a given
combined mass of warm and cold ocean water in OC OTEC operation.
To summarize, the Claude-cycle OTEC offers the following advantages:
1. Less loss in temperature due to the use of heat exchangers (increased power
production);
2. Reduced heat exchanger expenses, depending on whether or not fresh water is
produced (requiring surface condensers);
3. Relative immunity to biological fouling of surfaces.
While the past work of researchers in this area shows the overall feasibility of
such a system, a need for a more detailed technical updating of the system and its
components exists. Even though almost 50 years of engineering progress have
OPEN-CYCLE OTEC 215
elapsed since the time of Claude, many of the problems that he faced will not be
overcome by a mere updating of his work.
5.2.1 Evaporator
The evaporator supplies the OC OTEC plant with low-pressure steam produced by
vaporizing warm seawater. The evaporator is a vacuum chamber in which the
pressure is maintained below the saturation pressure (1/20 atmosphere pressure) of
the warm seawater. As the superheated seawater enters the low-pressure chamber,
some of it flashes to steam.
Assuming an adiabatic evaporator and that the system comes to thermody-
natnic equilibrium, energy balance of the flash process gives
where mH is the warm seawater mass flow rate, ms the steam mass flow rate, Cp
the specific heat capacity of seawater, TH the warm seawater inlet temperature, Tw
the warm seawater exit temperature, TE the saturated temperature at the evaporator
pressure, Hfg the steam enthalpy of evaporation at TE or atpE, and Hs the enthalpy
of the steam leaving the evaporator, as shown in Fig. 5-4.
The mass rate of steam flow generated by the evaporator is
and it is important that the water be used effectively and that the liquid head losses
or pressure drops be minimized. A well-designed evaporator delivers steam with an
acceptably low liquid content to the turbine and/or condenser(s), while minimizing
the overall cost. The vacuum boundary of the evaporator is usually incorporated
into the structure of the plant. A large proportion of the cost of the evaporator system
is the cost of the structural pressure boundary required to enclose it.
The water distribution system enhances evaporation effectiveness while
limiting head losses and platform area. Generally, evaporation is enhanced by a
large interfacial area at which vapor can be formed. Adequate superheating of the
inlet water (relative to saturation conditions in the evaporator) must also be allowed
in order to yield a high effectiveness. The effectiveness is defined as:
evaporator, no sealing is required. As a result, the brine free falls from the channel
to a brine collector and is discharged back into the ocean at sufficient depth to
preclude mixing with inlet flows. This concept has been successfully used in
multistage flash evaporators and is known to be a low-pressure-drop option.
However, horizontal channels are unlikely to perform at nearly theoretical effec-
tiveness due to rapid suppression of evaporation caused by hydrostatic pressure in
the channel. The effectiveness of the Westinghouse evaporator was estimated to be
about 80%.
The Westinghouse flash evaporator is a toroidal open-channel flow type. The
turbine is located on the center of the vertical axis and above the plane of the toroid.
Steam released in the flashing process flows vertically upward from the open
channel and then inward and down to the turbine, as shown in Fig. 5-5.
Equations of the sluice gate volumetric flow, empirical discharge and contrac-
tion coefficients, mass balance, energy balance, pressure summation, temperature
summation, generated steam vapor-brine ratio, and generated steam vaporair
ration of the flash evaporator of the Westinghouse 100-MW OTEC design have
been derived. The pressure drop, the steam vapor production flow, the air produc-
tion flow, and the size of the multistage flash evaporator have been calculated and
designed based on those equations, and several control factors including specific
mass velocity, interfacing constraints, a moisture carryover removal device, and the
degree of thermal nonequilibrium in the flash evaporation process. At the low
pressures and temperatures experienced in an OC OTEC plant, flashing can be
conservatively conceived as a surface evaporation process. Assuming a surface
evaporation process, Westinghouse obtained results for a rectangular, open-
channel flash evaporator with a baseline design tray length of 20 m (65.6 ft). An
overall platform cost and volume as functions of flash evaporator specific mass
flow rate was developed by Westinghouse, who estimated the platform cost as
$495/kW (1977 value) and the approximate platform outside diameter as 106.7 m
(350 ft).
The University of Massachusetts study (Boot and McGowan, 1974) selected
a vertical falling film flash evaporator for the open-cycle power module. The
disadvantages of this design are the large free-fall height and the high turbine cost.
The free fall is lost head and must be compensated by pumping power. The
effectiveness of the falling film evaporators was estimated by Bugby et al. (1983)
and ranged from 0.75 to 0.95.
The vertical spout evaporator originally suggested by Claude combines the
unobstructed vapor path of the open-channel configuration with the large interfa-
cial surface area generated by the falling-jets type. Effectiveness ranging from 0.85
to 0.97 was measured by Bharathan et al. (1983) and Ghiaasiaan and Wassel (1983).
The channel-flow flash evaporator (Lewandowski et al., 1982) and the vertical
spout evaporator performance analysis have been performed by Lewandowski et al.
(1982) and Block (1984), respectively.
Evaporation from falling superheated water jets for application to OC OTEC
power plants was considered by Wassel and Ghiaasiaan (1985), Green et al. (1981),
Kogan et al. (1980), and Fournier (1985). Analyses and experimental results were
performed to show that the interfacial resistance was of no importance to evaporator
design and that evaporation was liquid-side controlled. The heat exchanger perfor-
mance was presented in terms of its effectiveness and change of bulk temperature.
Mass transfer (Leninger, 1983) and experimental (Ofer, 1983) evaporation
from round turbine water jets of varying velocity, diameter, and length have been
studied. Experimental data for liquid-side mass and heat transfer coefficients have
been presented.
A heat exchanger evaluation of old and new concepts was carried out by Bell
(1983) to update information on the OTEC heat exchanger.
A sketch (Kreith and Bharathan, 1987) of the typical spout evaporator is
shown in Fig. 5-6. The sequence of spout appearance (Larsen-Basse et al., 1986) is
shown in Fig. 5-7. In the initial stage, before boiling has begun, the water exits the
spout to form an umbrella-shaped sheet (Fig. 5-7a). At lower vacuum levels bubbles
begin to develop in the spout upcomer, and at a certain point bubbles also form in
the umbrella-shaped sheet to the point where the sheet has a honeycomb structure
(Fig. 5-7b). As the pressure drops slightly farther, vigorous boiling sets in, starting
in the upper part of the upcomer, and droplets are ejected into the chamber at
substantial velocity (Fig. 5-7c).
OPEN-CYCLE OTEC 219
FIG. 5-6. Sketch of a single spout evaporator (Kreith and Bharathan, 1987).
5.2.2 Condenser
After expanding through the steam turbine of the open-cycle OTEC system, the
steam is condensed in either a surface condenser or a direct-contact condenser by
cold water from the ocean depth. Typically, the surface condensers are shell-and-
tube configurations with cold water flowing inside the tubes and steam condensing
on the outside of the tubes. Data on the performance of the surface condenser are
available. For the expense of adding a surface condenser, the open-cycle OTEC
plant can be configured to provide fresh water in addition to power. The surface
condenser consists of a heat transfer surface across which the heat released by
condensing steam is transferred to the cold seawater. A potential advantage of the
open-cycle OTEC systems is that it allows the use of direct-contact condensers
instead of the conventional surface heat exchangers required in closed-cycle OTEC
systems. Direct contact heat transfer results in a lower temperature difference
between the water vapor working fluid and the seawater, which implies a higher
220 OCEAN THERMAL ENERGY CONVERSION
conversion efficiency, lower seawater flow requirement, and lower capital cost.
However, this system cannot provide fresh water as a product. These two types of
condensers are discussed in the following sections.
5.2.2.1 Direct Contact Condenser
Direct contact condensers were used with steam engines and turbines to obtain low
exhaust pressures and high thermal efficiencies; however, with the adaption of
closed-cycle boiler water systems and the need for boiler feedwater treatment, they
were replaced with surface condensers. The use of surface condensers became
standard with the introduction of high-temperature steam turbines around 1900.
From that time, the importance of direct-contact condensers in power plants
steadily decreased.
There are little general design data for direct-contact condensers. They are
mostly designed using empirical data for particular applications, sizes, and fluids.
Design work has generally been carried out by "rules of thumb." The open-cycle
OTEC application of a direct-contact condenser is unique because of the large
amount of noncondensable gases, low-temperature driving force, and low pressure
level.
The direct-contact condenser for the open-cycle system may be a "jet"-type or
a "spray"-type condensing unit. There is no surface separating the steam from the
coolant, and inefficiencies associated with the thermal resistance of a heat ex-
changer surface are eliminated. In addition, the expense of a heat exchanger surface
is eliminated in the direct-contact condenser. Because the condensed steam is
mixed with the cold seawater, the direct-contact condenser does not produce fresh
water.
As the cold seawater absorbs the latent heat of the condensing steam, its
temperature rises, and an approximate heat balance yields
where mL is the mass rate of steam condensed into liquid, rhc is the mass flow rate
of cold seawater, C is the heat capacity of cold seawater, TL is the exit temperature
of cold seawater, Tc is the inlet temperature of cold seawater, and H, is the latent
heat of vaporization of steam.
If the coolant temperature rise is 5C (9F), roughly 100 kg (220 Ib) of cold
water is required for each kilogram of steam condensed. In a typical application,
cold seawater is available at 5C (41F), and the steam enters the condenser with
a saturation temperature between 10C (50F) and 15C (59F) [corresponding to
a vapor pressure between 1.2 kPa (0.1741 psi) and 1.7 kPa (0.2467 psi)J.
The condenser performance (Block, 1984) can be characterized by an effec-
tiveness defined as
OPEN-CYCLE OTEC 221
where U is the volumetric heat transfer coefficient (kWe/m3 C); the tempera-
ture driving force (F); and/7/po the condenser pressure/atmospheric pressure ratio,
where Ke is the entrainment coefficient (usually 0.05-0.15 m/s), p/ the liquid density
(kg/m3), and pg the vapor density (kg/m3).
The initial design height of the Westinghouse direct contact condenser is 0.884
m (2.9 ft) for a steam flow rate 1.36 x 106 kg/h (3 x 106 Ib/h), and a 0.278C (0.5F)
terminal temperature difference with a cold seawater flow rate of 270 x 106 kg/h
(594 x 106 Ib/h). The inlet and saturation temperatures of the cold seawater are 5C
(40F) and 7.78C (46F), respectively. Note that the cold seawater flow rate
required is reduced (compared with that of a surface condenser) because of the
much smaller terminal temperature difference.
Gases from the flashed hot seawater, from air leakage into the OTEC OC
vessel, and from air liberated in the direct-contact condenser must be considered in
determining the size of the unit. A large portion of the cost of the unit is the cost of
the vacuum boundary required to contain it. Thus the unit should be small to be cost
effective.
Steam condensation on falling water jets has been studied by many investiga-
tors in recent years. Experimental programs have produced correlations relating the
222 OCEAN THERMAL ENERGY CONVERSION
Stanton number to such parameters as the jet Reynolds number, Prandtl number,
Weber number, jet length and thickness, coolant subcooling, and air content of the
steam. The Stanton number is defined as:
where, h is the heat transfer coefficient based on jet surface area (W/m2 C), pc the
coolant density (kg/m3), V/ the jet velocity (m/s), and Cp the coolant heat capacity
(J/kg C).
With a constant saturation temperature in the vapor phase, the condenser effective-
ness can be related to the Stanton number by:
OPEN-CYCLE OTEC 223
where L is the jet length (m) and t the jet thickness (m).
Bharathan (1981) and Sam et al. (1982) have studied falling jet condensers
under OC OTEC conditions. Bharathan et al. measured the performance of multiple
planar jets 3.2 mm thick and 76 cm high with concurrent vapor flow. The Stanton
number was a weak function of the jet Reynolds number, coolant temperature, or
steam loading. With no noncondensables present, the data showed:
plant surface condensers are shell-and-tube configurations, with cold water flowing
inside the tubes and steam condensing on the outside of the tubes (shell side). Thus
the surface condenser configuration (Block, 1984) would be a shell and tube with
condensation occurring on the shell side. The steam pressure in a typical OC OTEC
surface condenser is on the order of 1.500 kPa (0.22 psi), corresponding to a
saturation temperature of approximately 12C (54F). The surface condenser heat
transfer can be characterized by the log mean temperature difference, or LMTD,
defined as:
where TL is the cold seawater exit temperature, Tc the cold seawater inlet tempera-
ture, and Ts the steam saturation temperature.
With cold seawater available at 5C (41F), and assuming a coolant tempera-
ture rise of 5C, the LMTD in the OC OTEC surface condenser is roughly 4C
(7.2F), compared to 5 or 6C in conventional power plant condensers. Thus the
driving force for heat transfer is reduced by 20 to 33% in the OC OTEC surface
condenser. Because of the small available temperature difference, a large surface
area is required for heat transfer and the ratio of cooling water to steam condensed
is quite high.
Noncondensable gases degrade condensation heat transfer by collecting
around condenser tubes as the steam condenses. This implies an added resistance
to heat and mass transfer through the layer of noncondensable gases. The impact of
noncondensables must be added to the thermal resistance of the condensate film, the
tube wall, and the coolant inside the tubes.
Fouling of condenser tubes has been anticipated as an added resistance to heat
transfer. Typical fouling resistances when seawater at normal temperature is used
as a coolant are on the order of 0.0001 W/m2 K (Fraas and Ozisik, 1965). Cold
seawater, typical of OTEC operation, has been shown to produce negligible fouling
compared to typical shore-based power plants because of its purity and lack of
biological activity. Larsen-Basse (1983) observed no fouling with cold deep-ocean
water in a test that extended for 1000 days.
The choice of tube material in the surface condenser must be made on the basis
of cost and anticipated durability. Enhanced tube surfaces, employing internal fins
and/or corrugations on the condensate film side, may be cost effective for OC
OTEC systems. The tradeoff is one of enhanced heat transfer performance versus
increased capital costs and increased parasitic losses caused by additional friction
in the tubes.
Large-scale steam surface condensers have been employed in the power
industry for many years. There exists a large base of condenser performance data
and design experience. In part, standard design considerations can be applied to the
OC OTEC surface condenser. Manufacturers typically include steam lanes to direct
the vapor flow into the tube bank and to ensure that noncondensable gases are swept
to a point of removal. Baffles are commonly employed to direct the vapor through
the coldest region of the condenser just prior to the point of noncondensable
OPEN-CYCLE OTEC 225
removal. By rule of thumb, steam velocities of at least 30 m/s (98.4 ft/s) are
maintained in order to effectively sweep the noncondensables to the exit.
In other respects, the OC OTEC surface condenser lies outside the ordinary
design limits for power plant condensers. The vapor pressure is no greater than
1.500 kPa (0.22 psi), compared to 3.4-6.8 kPa (0.50-1.0 psi) in more standard low-
pressure steam applications. The total temperature difference between steam and
cooling water is 5 to 7C (9 to 12.6F) at OC OTEC conditions, while 12C (21.6F)
or more is typical in the power industry. Thus the driving force for heat transfer is
over 50% lower than in standard steam condensers. Similarly, the available coolant
temperature rise is roughly halved, implying a higher mass flow rate of coolant. The
OC OTEC condenser is also faced with a higher-than-normal noncondensable mass
fraction in the inlet steam (0.2 to 0.4% anticipated).
No full-scale steam surface condenser performance data are available at OC
OTEC conditions. Most experimental programs have been conducted outside the
extremely low pressure and low temperature difference range of OC OTEC
systems. A brief review of analytical approaches and experimental results for the
OC OTEC surface condenser design is available (Block, 1984).
An analytical approach to condenser analysis or design includes the thermal
resistance of the condensate film and the tube wall, forced convection to the cooling
water, and the effect of noncondensable gases in the vapor phase. The standard
analytical technique is to use Nusselt's theory and the Colburn-Hougen method to
calculate forced convection inside the tubes using an equation such as the Dittus-
Boelter correlation.
Experimental results by Sklover and Grigorev (1975), Fuks and Bernova
(1970), Bobe and Malyshev (1971), Buglaev et al. (1971), Mills et al. (1974),
Henderson and Marchello (1969), etc. have correlated the mass transfer Nusselt
number and friction factor for steam in air as a function of Reynolds number and
Prandtl number at various conditions.
The water-side heat transfer and pressure drop can be calculated using
standard thermohydraulic equations discussed in detail in Chapter 4.
Eight surface enhancement arrangements were considered as promising for
the surface condenser in the Westinghouse 100-MW OC OTEC system design.
Tube materials selected were 90-10 Cu-Ni, aluminum, and titanium. Enhanced
surfaces considered were applied coatings, fins, corrugations, and flutes. Only
those surfaces that had comparable test data available and had been manufactured
in sufficient quantity were selected by the Westinghouse project. The eight steam
condensers are listed in the report from Westinghouse Electric Co. (1978). The
inside heat transfer coefficients and friction factors, the tube metal wall heat
resistance, the outside heat transfer and pressure drop, surface area calculation,
weight, and cost of the OC OTEC surface condenser are also discussed (Westinghouse
Electric Co., 1978).
The University of Massachusetts study (1974) chose a small l-in.-diameter
tube with a low inside velocity of 3.05 m/s (10 fl/s). The shell diameter is 14.8 m
(48.57 ft); total number of tubes is 154,276; the core length is 12.4 m (40.76 ft); the
overall heat transfer coefficient is 3.98 kW/m 2 C (686.3 Btu/h ft2 F); the total heat
226 OCEAN THERMAL ENERGY CONVERSION
area is 201,200 m2 (2,165,00 ft2); the core pressure drop is 45.9 kPa (6.80 psi); and
the cooling water pumping work required is 13.6 MW. The turbine exhaust mass
flow rate is 1309 kg/s (2.88 x 103 Ib/s); and the mass flow rate of the cold ocean water
is 2.70 x 105 kg/s (5.95 x 105 Ib/s) for the 100-MW OC OTEC preliminary design
project.
Results of experiments and analyses that determine jet flow distribution from
slotted pipes of dimensions typical for OC OTEC condensers are described by
Olson (1981). Apparatus for OC OTEC heat and mass transfer experiments,
including single- and three-vertical spout, deaeration, and scoping test of a surface
condenser at the sea coast test as applied to OC OTEC condensers, is also given by
Panchal (Panchal and Bell, 1984; Panchal and Stevens, 1986). The state of the art
of heat and mass transfer related to condensation of steam at low pressure in OC
OTEC is summarized by Bharathan et al. (1984). These experimental data on steam
condensation can be extended to the conditions encountered in OC OTEC systems.
Design of the condenser can be based on established analytical techniques such as
the Nusselt analysis.
5.2.3 Turbine
The large volumetric rate of steam flow necessary in the open-cycle OTEC system
results in a unique large and expensive turbine. The turbine is a significant element
of the open-cycle OTEC system (Westinghouse Electric Co., 1978). Several
investigators have stated that the cost of the turbine alone made the open-cycle
OTEC power system uncompetitive. However, through the recent research, intro-
duction of unique design concepts, development of materials, fabrication, and other
advances in technologies, turbines for the open-cycle OTEC system could be both
economically and technically feasible.
The turbine system consists of the turbine rotor, stator, bearing, generator, and
power conditioning equipment. The steam flows from the evaporator through a
fixed blade row (stator), which imparts tangential velocity to the flow. The angular
momentum is extracted by the rotor, and the nominally axial discharge flow passes
through a diffusing section to the condenser.
A thermodynamic analysis of turbine performance and geometry is described
in detail by Lewandowski et al. (1980).
Selection of a particular type of turbine for a specific application depends on
the maximum efficiency potential for the turbine type at the operating conditions.
The specific speed, Ns, and specific diameter, Ds, in terms of rotational speed
in rpm (AT), exit volumetric flow in m3/s (Qe), tip diameter in m (D), and isentropic
enthalpy drop across the machine in m, are given by Coleman et al. (1981)
For an OC OTEC turbine operating with nearly saturated steam at 21C inlet
temperature and an 8 to 10C temperature drop, axial flow turbines are chosen
OPEN-CYCLE OTEC 227
(Parsons et al., 1985) because the most efficient turbine at the OC OTEC operating
condition is an axial flow turbine with an efficiency of around 80%. There is also
a large specific speed range over which high efficiencies are possible with axial
flow turbines.
The aerodynamic design of axial turbines is a mature technology. Sophisti-
cated design methods, based on fundamental physics and buttressed with experi-
mental factors, have been developed by the major turbine manufacturers. The
boundaries of these design methods are set by the major nondimensional groups:
specific speed, specific diameter, Mach number, and Reynolds number. If the
operating conditions, overall diameter, and speed fall inside these boundaries, a
detailed blade design effort will succeed in producing an aerodynamic efficiency
exceeding 80% (Block, 1984).
The mechanical design of turbines large enough for OC OTEC ,systems
remains speculative. The largest turbine today is the last low-pressure stage of a
nuclear power plant. These steel alloy (stainless steel) blades are up to 1.1 m long
and are attached to a disk of approximately 2.0 m diameter. Such a stage run at
typical OC OTEC conditions would generate about 1.6 MWe. (In the typical dual
flow configuration it would generate about 3 MWe.)
For larger OTEC plants, Westinghouse (1978) has suggested fiberglass-
reinforced plastic (FRP) rotor blades. Their study covered OC OTEC turbines to
140-MWe gross power output. Extensive review of aerodynamics, aeroelasticity,
stress, fabrication techniques, and cost has uncovered no barrier to the production
of such blades. However, construction of an FRP turbine must be regarded as a
major development effort.
The Westinghouse (1978) turbine design uses three basic building blocks that
form its OC OTEC turbine model. The three blocks are turbine performance model,
turbine mechanical model, and turbine cost model. The turbine mechanical model
is used to determine the basic geometric turbine parameters, including the blade
diameter, blade height, thickness, etc. To meet the thermodynamic and fluid
dynamic requirements, the turbine mechanical model determines stresses such as
the blade bending stress, centrifugal stress, and tangential stress. The model makes
sure that these stresses are within acceptable levels at industry accepted factors of
safety. The turbine cost model predicts the overall cost of potential design
alternatives. Exercising the three models over a wide range of pertinent design
parameters, Westinghouse provided the information to develop an excellent
conceptual turbine design (Coleman et al., 1981).
The University of Massachusetts (Boot and McGowan, 1974) turbine design
is based on a 1.36-kPa (0.2-psi) pressure head across the turbine and a steam mass
flow of gross output power. An axial flow turbine with a specific speed of 120 and
specific diameter of 1.2 is designed to rotate at 139 rpm and has a turbine blade
diameter of 5 8 m (191 ft) for a net power of 100 MW per OC OTEC plant. A radial
inflow turbine with a specific speed of 80, specific diameter of 1.4, turbine blade
of 68 m (223 ft), and 92.8 rpm rotating speed was also investigated. Since the size
of one turbine for the OC OTEC cycle is extremely large, it might be necessary to
have several smaller turbines instead of one large turbine (Lewandowski et al.,
228 OCEAN THERMAL ENERGY CONVERSION
1980; Watt et al, 1978). Analysis has shown that the relative size of five individual
axial and radial turbine sizes are 26.2 m (86 ft) and 30.5 m (100 ft), respectively.
Rosard (1978) examined turbine sizes, speeds, and efficiencies for various
candidate working fluids for OC OTEC power systems. The turbine performance
and design limits were found to be strongly influenced by blade stress criteria,
which had been ignored previously by investigators.
The design of a low-pressure OC OTEC plant is described by Coleman et al.
(1981). Small-scale turbine rotors made from composites (Penney, 1986) offer
several technical advantages for an OC OTEC plant. Penney (1986) designed a
composite turbine rotor using state-of-the-art analysis methods for large-scale
(100-MW) OC OTEC applications. Successful near-term tests using conventional
low-pressure turbine blade shapes with composite materials would demonstrate
feasibility and modern credibility of the OC OTEC power plant. Application of
composite blades for low-pressure turbo-machinery potentially improves the
reliability of conventional metal blades affected by stress corrosion. A partial rotor
assembly of the Penney design is shown in Fig. 5-9.
Preliminary studies were being conducted by University of Pennsylvania,
Texas A & M, and Massachusetts Institute of Technology in 1989 to identify and
evaluate advanced turbine concepts for the open-cycle power system. These steam
turbines have the potential to reduce the cost of OTEC electrical power plants
significantly. The three concepts are (1) a cross-flow turbine, (2) a vertical-axis,
axial-flow turbine, and (3) a double-flow, radial-inflow turbine with mixed-flow
blading. In all cases, the concept involves the use of light-weight, composite plastic
blading and a physical geometry that facilitates efficient fluid flow to and from the
other major system components and reduces the structural requirements for the
turbine or the system vacuum enclosure, or both. These concepts were all found to
be workable. Key issues with respect to cost reduction remain on overall system
integration and use of low-cost composite material for blading.
Dissolved oxygen and nitrogen gases are present in seawater. Some of these gases
evolve when the seawater enters a containment power module under vacuum. Air
leakage also exists because the containment is under vacuum. These gases signifi-
cantly lower the heat transfer coefficients on the vapor side in the condenser and
decrease the pressure drop across the turbine. This problem must be overcome by
continuous operation of the vacuum pump in the condenser chamber of the system
containment structure. These gases must also be removed to maintain the vacuum
of the containment power module. The power requirement of the vacuum pump is
also significant.
Oxygen and nitrogen are present in the seawater at normal OTEC operating
temperature at 6.4 and 10.8ppm,respectively(Dukler, 1971; Watt etal., 1977). The
air leakage rate is assumed to be 1820 kg/h (4000 Ib/h) regardless of the power
module size (Boot et al., 1974).
For the open cycle with a surface condenser, conventional shell-and-tube
condensers are used. The gases in the cold seawater will remain in solution since
the cold seawater always remains in closed pressurized conduits. Only the gases in
the hot seawater and the air leakage must be removed. For the open cycle with a
direct-contact condenser, the gases liberated by the cold seawater also must be
removed.
The gases in the warm seawater can be removed in one or more deaerators
located upstream of the flash evaporator. The remaining gases plus the air leakage
must pass through the system along with the steam and must be removed continu-
ously from the condensers. Sophisticated design is necessary to avoid loss of steam
along with the noncondensable gases being expelled. For the open cycle with the
direct-contact condenser, deaerators can also be used before the condenser in the
cold-water loop.
The exhaust system consists of a series of stages. Each stage has a deaerator,
a vent condenser, and a compressor, as shown in Fig. 5-10 (Lewandowski et al.,
1980). Aerated seawater, consisting of dissolved air and water, enters at stage N.
The vent condenser maintains a pressure above the stage larger than the vapor
saturation pressure at the water temperature, drawing air out of the seawater. Each
successive deaerator stage operates at a lower pressure. The pressures in the stages
are fixed by the vent condensers. Air and water vapor enter the first vent condenser
from the last stage in the staged system. Much of the liberated water vapor is
230 OCEAN THERMAL ENERGY CONVERSION
condensed by the intercoolers to reduce the amount of gas that must be compressed.
A compressor pumps the remaining mixture to the next vent condenser, fixing its
operating pressure and the stage 2 deaerator operating pressure (higher than stage
1). Air and water vapor are added from the stage 2 deaerator, compressed to the next
vent condenser, and so on down the line. The main purpose of a staged system is
to reduce the amount of air removed at low pressure. Compression efficiency
decreases with decreasing pressure; therefore a greater penalty is applied to the low-
pressure stages.
A four-stage system consists of four compressors with three vent condensers
located between the compressors. There is no vent condenser before the first stage,
since it operates at the same temperature as the incoming water vapor.
The total mass flow rate through the first compressor, mtt\, is the sum of air
flow ma and uncondensed vapor mro
where y is the compression ratio per stage, ps1 is the pressure in stage 1, p0 is the
outlet pressure of the multistage system, is the vent condenser pressure drop, and
n is the number of stages.
The flow of vapor through subsequent compressors is reduced by the vent
condensers. The vapor flow for rth-stage compressor, m r j, is
OPEN-CYCLE OTEC 231
where Ma and Mw are the molecular weights of air and water vapor, respectively,
Pvc in is the saturated water vapor pressure at inlet water temperature, and Pa,,i is the
air pressure at the inlet of the rth-stage compressor.
The total flow through the ith-stage compressor, mti, is
The power required to compress this flow for the fth stage can be computed.
The total power required for the system is the sum of the power for each compressor.
The University of Massachusetts study (1974) assumed that all the liquid
sprayed into the evaporator gave up its noncondensable gases. This flow of gas was
pumped from the condenser, where it was at 10C (50F) and 1360 Pa (0.2 psi), to
the ocean's surface, where it was expelled at atmosphere pressure. The deaeration
pump work was found to be 8.2 MW (Hagan, 1975), or a fraction of 5.8% of the
gross power.
The Westinghouse study (1978) selected compressors with intermediate vent
condensers to exhaust the gases to the environment. The optimum number of
compressors determined by the study is between three and five. Two types of
compressors (roots and axial flow) were considered. The study concluded that axial
compressors were superior to the roots type because of the large rate of gas flow that
must be handled. The basis for this conclusion was the substantial reduction in the
power consumption with only a marginal cost increase. Vent condensers located
between the compressors were used to reduce the gas volumetric flow rate to the
following compressor. The impact of the vent condensers on the power and cost of
the air removal system was dramatic. The power required was reduced from 10.4
MW without vent condenser to 4.25 MW with three vent condensers, and the cost
was reduced from $3.50 x 106 to $2.4 x 106 (1978 value) for the Westinghouse
design. A thin film mechanism for promoting desorption to achieve deaeration of
seawater was selected by the Westinghouse design. The packing deaerator design
for a warm seawater flow rate of 4.54 x 108 kg/h (109 Ibm/h) was estimated at a cost
of $2.84 x 106 (1978 value), or $28.4 per net output kW.
A test loop for OTEC gas desorption was constructed by Oak Ridge National
Laboratory (Chen and Golshani, 1982), and experiments were carried out in three
areas: (1) vacuum deaeration in a packed column using plastic pall rings, (2)
deaeration in a barometric water intake system, and (3) disposal of noncondensables
through hydraulic air compression.
Subsystem analyses based on the experimental data have shown that a 10%
reduction both in deaeration cost and pumping power can be realized with a
combination of barometric intake and packed column deaeration.
Bugby et al. (1983) examined bubble nucleation and growth in the evaporator,
condenser, upcomers, and feedwater distribution systems of OC OTEC systems.
The phenomenon that has the most impact on OTEC system design is cavitation in
the warm-water feed near the entrance of the evaporator. The critical bubble size
for cavitation is about 105 um. Sources of bubbles in the warm-water feed are those
entering from the ocean, those nucleating on suspended particles, and those
232 OCEAN THERMAL ENERGY CONVERSION
An early study indicated that the size of the water pump could permit the
circulation pumps to be housed within the water inlet or outlet pipe.
and water flow rate, it is difficult to make valves large enough and fast enough to
ensure that the turbine steam flow rate, power, and torque stay within safe limits.
Westinghouse (1978) considered an electrical turbine-generator control system
involving feed-forward and feed-back modulation of a voltage regulator for speed
control.
5.2.7 SeawaterDueling
The function of the seawater ducting is to provide warm surface seawater to the
evaporators and cold deep seawater to the condensers, and return the effluent
streams to the sea. Although four seawater piping systems are required for operation
of an OC OTEC plant, it may be desirable to combine the warm and cold discharge
streams in one pipe.
5.2.7.1 Cold-Water Pipe
The majority of the closed-cycle OTEC power plant designs are sited on various
types of floating structures. However, most of the open-cycle OTEC power plant
designs are land based, which offers an attractive alternative to floating plants for
certain applications in specific locations (particularly islands). The general require-
ments of the cold-water pipe (CWP), including structure, design, and static and
dynamic forces acting on the CWP, at sea test, scale-model test, and material
selection, have been discussed in Chapter 4 on closed-cycle OTEC plants. Most of
these discussions also apply to open-cycle, land-based OTEC plants. The installa-
tion of the cold-water pipe of a land-based OTEC plant involves unique construc-
tion aspects. Both the large-diameter requirement (nominally 10 m for a 40-MW
plant) and the depth of water (1000 m) for installation exceed the current demon-
strated capabilities (Brewer, 1979) of the offshore pipe laying industry. Therefore
the design and deployment of the cold-water pipe is one of the most difficult and
challenging engineering tasks of the OC OTEC plant.
A variety of materials, construction techniques, and deployment methods have
been suggested (Brewer, 1979) for the cold-seawater pipe design based on the plant
type (i.e., land-based, shore-mounted, and shelf-mounted). A short list of candidate
pipe materials and the estimated cost (1979 value) for manufacturing an 1800-m
length of pipe for a 40-MW land-based OTEC plant is presented in Table 5-1. The
comparison is for the deep water, steeply sloped, portion of the cold-water intake
pipe only. There is no advantage of buoyant pipe in the shallow-water zone because
the pipe has to be trenched and buried.
The best method for installing the cold-water pipe in the deep water and steep
slope zone depends on many factors (Creare, Inc., 1984), which include:
1. Whether the pipe is installed in a single length or multiple sections;
2. Whether the pipe is transported to its final position along the sea floor or on the
surface;
3. Whether the pipe deployment proceeds toward the deeper water or toward the
shallower water;
4. The sea floor conditions along the pipe line route.
234 OCEAN THERMAL ENERGY CONVERSION
The installation method may be quite different for different situations (Brewer,
1979).
A schematic of the cold-water system of the Westinghouse floating (1978) OC
OTEC plant is shown in Fig. 5-11. The pump head, Wp, required for the system can
be analyzed by the energy equation:
where Hz, Hv, HP, Hc, and HM are the potential head, velocity head, piping frictional
head, minor head, and condenser head losses, respectively. These head losses are
expressed by the following equations.
where p,- and p,, are the seawater inside and outside densities, zt and z9 are the inlet
and discharge depth, V9 and V} are the seawater velocity at states 9 and 1 shown in
Fig. 5-11,/is the frictional factor of the pipe, / and D are the length and diameter
of the pipe, and KM is the minor loss factor. The Westinghouse 100-MW OC OTEC
floating plant (1978) assumes a water velocity of 2 m/s in the pipe, V1 = 1 m/s at the
screen inlet, V9 = 2 m/s at the pump discharge, a condenser head loss of 2.3 m, a cold
water inlet depth of 940 m, and a discharge depth of 100 m. The minor cold-water-
path viscous dissipation loss factors are: Kscreen = 3, Karea contraction - 0.05, and
K90o turn = 1. The head loss calculation shows that Hz = 0.41 m, Hv = 0.2 m,
Hp = 0.11 m, HM = 0.56 m, Hc = 2.3 m, and Wp - 3.37 m. Each of the four pumps
requires a power of 3490 kW and delivers a flow rate of 102 m3/s.
The cold-seawater pipe length of a land-based OC OTEC power plant will be
much longer than that of a floating plant. For example, the pipe proposed for an OC
OTEC plant at Hawaii (Brewer, 1979) is 1768 m in length and 6.7 m in diameter.
The pump power required to deliver a flow rate of 35 m3/s is a large portion (0.29)
of the total gross output power of the plant.
The cold seawater pipe cost (C) is assumed (Creare Inc., 1984) to be
proportional to the product of the length (L), diameter (D), and a cost factor K
without consideration of set-up and other related costs. The factor K is determined
from the seawater pipe data given by Creare, Inc. (1984):
warm-water distribution channel and manifold (if multimodules are used), then to
the evaporator heat exchangers. The warm-water pipe of a land-based 40-MW
closed-cycle OTEC pilot plant designed by Ocean Thermal Corporation (1983) is
a concrete pipe of 5.2 m (17 ft) inside diameter to provide about 1.5 million gal/min
of warm water to the plant.
Analysis of the warm-water system can be based upon the energy equation
from the inlet state 1 to evaporator outlet 7. The evaporator elevation /2 provides
the pressure, velocity, potential, and frictional head losses as
where Hp, Hv, Hz, HL, and H,, are the pressure head, velocity head, potential head,
frictional head, and evaporator losses, respectively. The head losses are expressed
by the following equations:
OPEN-CYCLE OTEC 237
where ps and pa are absolute pressure at the free surface inside (state 6) and outside
the warm-water system, p is the seawater density, v7 and v1 are the velocity at the
outlet of the evaporator and inlet of the pipe, l1 is the inlet depth,f is the frictional
factor of the pipe, / and D are the length and diameter of the pipe, v is the water
velocity in the pipe, and Ku are the minor loss factors of the system including inlet,
screen, turn, etc.
The Westinghouse 100-MW OC OTEC floating plant design (1978) has ps =
2.76 kN/m2 abs. (0.40 psia), v, = 1 m/s, v = 2 m/s, D = 3.6 m,/= 0.0116, ^scrcen =
1.5,v7 = 0,Ar areacontraction = 0.05 ) ^ expansion = ! , / = / , + /2 = 40 m, ffz = 0.005 m,Hv
= Qm,HM = 0.39 m, HH = 0.2 m, Hp - 12 = 0.60 m, and 12 = 9.45 m.
The warm-water discharge from the evaporators of the OC OTEC plant shown
in Fig. 5-12 can also be analyzed by the energy equation
where Wp is the pump head, HE is the head required to extract water from the low-
pressure evaporator chamber, Hz is the potential head loss as water flows from state
7 to sea level, Hvis the velocity head loss from state 7 to 11, H, is the frictional head
loss, and HP is the pressure head.
The Westinghouse study (1978) gives Vpump discharge = 2 m/s, HE = 2.1 m,
Hp = 10.05 m, Hz =7.35 m, HL = 0.14 m, Hv=0.2 m, and WP = 3A m.
The warm-water discharge and cold-water discharge from the evaporators and
condensers of the OC OTEC plant may be mixed after passage through the heat
exchangers. The mix effluents are then discharged to a certain depth, where they
sink to the equivalent density depth.
In summary, floating plants offer potentially the lowest structure and pipe
costs, offset by high mooring costs for plants designed for electric power transmis-
sion to shore. Tradeoffs exist between uncertainty and risk vis-a-vis CWP installa-
tion and storm survival. Shelf mounting exchanges substantial foundation costs for
high mooring costs, reduces survival uncertainty, increases CWP length and cost,
and raises new uncertainties relative to deployment of bottom-mounted CWPs.
Shore-mounted or surf-zone sites reduce foundation costs, further reduce survival
uncertainty, and increase pipe length, number, and installation cost. Land basing
increases construction and foundation costs and pumping costs, along with pipe
length and installation costs, but virtually eliminates platform risk and uncertainty
and eases operation.
Both concrete and steel have been extensively studied for OC OTEC plant
construction materials. Reinforced concrete provides lower installation cost and
substantially lower maintenance cost, due to corrosion of steel in the marine
environment. Concrete of high quality and minimum water content shows excellent
marine durability. Care must be exercised to provide adequate coverage of
reinforcing steel, to minimize chloride penetration and depassivation of the steel
(Browne and Bury, 1981). Air permeability is low and may be kept low by periodic
application of external sealant coats on exposed surfaces while plant vacuum is
maintained. Use of plasticizers may be beneficial to enhance the workability of low-
water concrete mix. Installed costs may be accurately estimated on the basis of
concrete volume, assuming conventional shapes and reinforcement (Barr and
Chang, 1977). The structure cost model used a value of $l,540/m3 (1983$) for
installed reinforce concrete.
The unit area cost estimation of the structure (ZIA) in 1983 dollars per unit
plant area in square meters given by Creare R and D, Inc. (1984) is roughly a
constant due to the need for ballast weights:
For a small 1 -MW OC OTEC power plant with a plan area of 117 m2 designed
by Penney (1984), the cost estimation is $9831 per unit area.
at 13.8 kV and is sent via a 56-MVA, 13.8- to 138-kV step-up transformer to the
electric utility. The transmission voltage of 138 kV is selected to match the
transmission voltage of the local electric power company. Transformers and switch
gears should be housed in enclosures and supplied with force ventilated, filtered air
to reduce corrosion. Conventional oil-filled cables are selected for transmitting
power to the onshore grid.
5.3 HYBRID CYCLE
5.3.1 System Analysis
The hybrid-cycle OTEC system is one of the variations on the standard open-cycle
OTEC system. It is a blend of both the open and closed cycles designed to produce
both electric power and fresh water as OTEC products. The hybrid cycle is an
attempt to combine the best features and avoid the worst features of the open and
closed cycles.
The focus of the U.S. OTEC program was shifted in 1980 from large (100- to
400-MW) floating plants to small (10- to 40-MW) shore-based plants for early
commercialization. Small plants have potential applications for the island market.
Moreover, some islands can use desalinated water, which can be produced by a
hybrid OTEC plant. Small hybrid OTEC plants for simultaneous production of
desalinated water and power could have greater potential for islands and deserts
than the closed and open cycles for power production alone.
In the hybrid cycle (Panchal and Bell, 1987), the warm seawater is flash
evaporated under vacuum to steam (as in OC OTEC systems), as shown by process
1-2 of the T-S diagram in Fig. 5-13. The heat in the resulting low-pressure steam
is then transferred via a heat exchanger to ammonia in a conventional closed
Rankine cycle system and condensed in the ammonia evaporator as shown by
process 3-4. The drop in the condensation temperature from state 3 to state 4 is due
to the combined effects of noncondensable gas evolved from the seawater and
steam-side pressure drop. Ammonia, evaporating in process 5-6, is passed through
the turbine in process 6-7 and is condensed in a surface condenser in process 7-8.
Cold seawater is sensibly warmed in passing through the condenser, process 9-10.
The schematic diagram of the hybrid OTEC power system is illustrated in Fig.
5-14. Warm seawater is pumped from a depth of about 10 to 15 m. It is flash
evaporated, and about 0.5% of the water flow is converted into low-pressure steam.
During the flash evaporation, dissolved gases evolve. The low-pressure steam
flows to the ammonia evaporator, where about 95% of the steam is condensed. All
of the steam cannot be condensed due to the presence of noncondensable gases that
reduce the condensation temperature. Therefore, an optimum fraction of steam that
should be condensed in the ammonia evaporator needs to be determined for a given
set of operating conditions.
The major part of the remaining steam is condensed in the condenser, where
ammonia from the condenser is used as a coolant. Alternatively, cold seawater can
be used as a coolant in the vent condenser. However, ammonia is the better choice
for the following reasons:
OPEN-CYCLE OTEC 241
where AE and Ac are evaporator and condenser surface areas, QE and Qc are heat
transfers in the evaporator and condenser, UE and Uc are overall heat transfer
coefficients of the evaporator and condenser, and (LMTD) and (LMTD)C are the
log mean temperature differences between the ammonia and seawater in the
evaporator and condenser, respectively.
where 'ww/, rhA, and mc are the mass rates of flow of the warm flashed seawater,
ammonia, and cold seawater, respectively; C} is the heat capacity of seawater; Tis
the temperature of the seawater; and H is the enthalpy of the ammonia at various
thermodynamic states shown in Fig. 5-13.
The basic heat exchange analysis and design factors of the hybrid ammonia
closed cycle are very similar to those of the closed cycle, which have been discussed
in detail in Chapter 4.
Vacuum deaerators are required in the hybrid cycle. The presence of
noncondensable gases, particularly oxygen, in the hybrid-system ammonia evapo-
rator creates the potential for excessive corrosion. In addition, performance
degradation of the system results from the blanketing of heat transfer surface by the
noncondensable gases in the hybrid system ammonia evaporator. The basic flash
evaporator and deaerator analysis and design factors of the hybrid system are
similar to those of the open system discussed in Section 5.2.1.
The ammonia turbine and pump of the hybrid system are related to the
thermodynamic states (Fig. 5-13) by the following equations:
where WT is the actual turbine power delivered, Wp is the actual pump power
needed, and riT and 17 are the turbine and pump efficiencies of the ammonia closed
cycle, respectively.
The analysis and design factors of the ammonia turbine and pump have been
discussed in Chapter 4. The flash evaporator has been discussed in Section 5.1.1.
The mass rate of steam flow generated by the evaporator is
where mw is the warm seawater mass flow rate, C} is the specific heat capacity of
seawater, T{ is the warm seawater inlet temperature, T2 is the warm seawaler outlet
244 OCEAN THERMAL ENERGY CONVERSION
Table 5-2. Power system parameters for 10-MW hybrid-cycle OTEC plant
Vertical spouts flash evaporator
Rate of heat transfer 639 (MW)
Water flow rate 42,560 (kg/s)
Rate of steam generation 261 (kg/s)
Water velocity in spouts 1 .83 (m/s)
Number of spouts 1799
Rate of clesorption of gases 0.68 (kg/s)
Brazed aluminum plate-fin ammonia evaporator and steam condenser
Rate of heat transfer 607 (MW)
Fraction of steam condensed 0.95
Heat exchanger area 84,1 60 (nr)
Steam-side channel size 44.5 (mm)
Ammonia-side channel size 7. 1 (mm)
Brazed aluminum plate-fin vent condenser
Rate of heat transfer 30.8 (MW)
Fraction of steam condensed 0.9
Heat exchanger area 8400 (m2)
Steam-side channel size 31.7 (mm)
Ammonia-side channel size 6.35 (mm)
Titanium shell-and-tube ammonia condenser
Rate of heat transfer 620 (MW)
Tube diameter 25.4 (mm)
Tube length 15.2(m)
Heat transfer area 80,532 (m 2 )
Gas compressor system
Number of stages 5
Inlet steam-to-gas ratio 0.7
Inlet pressure 2.58 (kPa)
Compressor efficiency 0.8
OPEN-CYCLE OTEC 245
device with associated control systems should dampen the effects of ocean
dynamics on the flash-evaporation process and the resulting steam pressure.
The low-pressure steam, generated in the flash evaporator, flows to the
ammonia evaporator. About 95% of the steam is condensed in the ammonia
evaporator. It is an aluminum plate-fin heat exchanger, assembled using a brazing
technique. Aluminum has proved to be suitable for closed-cycle heat exchangers,
which do have contact with seawater. Steam condenses in horizontal channels
formed by the fins while ammonia evaporates on vertical channels formed by
serrated channels. The condensate is pumped to a fresh-water storage tank.
The hybrid OTEC plant discussed (Panchal and Bell, 1987) produces 2.25
million liters per day of desalinated water per MWe of electric power generation.
If the ratio of water to power production needs to be other than the above value, the
hybrid-cycle plant can be designed accordingly. On the other hand, for a certain
range of operating conditions, this plant can be operated off design conditions for
production of additional desalinated water at reduced net power generation. This
can be done either by lowering the flash-down temperature (i.e., increasing
temperature change for warm water) or bypassing the ammonia turbine (i.e.,
allowing the ammonia vapor to flow directly to the condenser). It is, however,
necessary to install a control system for such off-design operations. For a modular
plant system, one of the turbine modules can be shut down and the ammonia vapor
allowed to flow directly to the condenser, resulting in a 60 to 80% increase in water
production for that module. It should be noted that the net power generation
decreases by shutting down a module.
Since the available temperature difference for power production is small, it is
not possible to increase production of desalinated water significantly from a plant
that was optimized for power generation. However, certain design features can be
incorporated into the original design for required water production at a given power
generation level. Among other design options, provision for varying the warm
seawater flow rate seems to be an efficient and least expensive approach. In this
case, the warm-water pipe, flash evaporator, and ammonia evaporator are designed
for varying water flow and the corresponding rate of steam generation. The rest of
the system, including the cold-water flow system, remains essentially the same as
that for optimum power production.
Three different hybrid plant configurations have been studied by Creare, Inc.,
as shown in Fig. 5-16. One configuration is a single-stage (Plant 1.0) and two are
double-stage (Plants 2.0 and 2.1) plants. In the single-stage plant, all of the steam
is produced in one flash evaporator and condensed in a single surface condenser,
allowing for the production of both electricity and fresh water. Double-stage plants
have potentially higher efficiency than the single-stage plant and also can provide
greater flexibility of operation. Steam produced in the first-stage flash evaporator
is routed directly to a surface condenser to obtain fresh water, and steam from the
second flash evaporator is expanded through a turbine to produce power. Analyses
have been performed to determine the optimal plant configurations for the produc-
OPEN-CYCLE OTEC 247
FIG. 5-16. Single-stage and double-stage hybrid OTEC plant configurations (Creare, 1984).
tion of fresh water alone (a zero net power output), for combined power and fresh
water production, or for power production only. Results (Creare, Inc., 1984) show
that there was little cost difference between single- and double-stage plants in
generating power, but a double-stage plant was consistently more economical for
the production of water. The capital costs in 1983$/(m3/s) for the plants optimized
for fresh-water production were found to be $120 and $170 for double stage and
single stage, respectively, at a fresh-water production rate of 4 m3/s.
248 OCEAN THERMAL ENERGY CONVERSION
5.4.1 Concept
The Beck cycle is a modified Rankine cycle. Over a small range of temperatures
involved in OTEC (typically 22C) applications, constant property curves for steam
are nearly straight lines, as shown in the following T-S and p-v diagrams (Fig.
5-19). Therefore, the T-S diagram of the Beck cycle is essentially a triangle.
Since ijc of the OTEC cycles is of the order 0.08, we find that the ideal Beck
cycle is very nearly one-half of the maximum possible Carnot cycle efficiency. The
p-v diagram of the Beck cycle is also a triangle. Since a rectangular cycle area on
the/7-v diagram represents the maximum possible extraction of work over a certain
pressure range, the Beck cycle is found to produce one-half the maximum work, too.
It was claimed that the Beck cycle was effective compared to other power cycles
when applied to OTEC.
A schematic diagram of the mist lift OTEC plant and its corresponding T-S
diagram are illustrated in Figs. 5-20 and 5-21. Warm seawater at state 1 is taken
from near the ocean surface, filtered, and allowed to descend through a penstock to
a hydraulic turbine inlet at state 2. There is a working pressure drop across the
hydraulic turbine, which is represented by the difference in level of states 1 and 2.
The exit water at state 3 from the turbine is sprayed upward in tiny jets into the
bottom mist generator (lifting duct), where the ambient pressure is slightly less than
the saturation vapor pressure of the injected water. Some of the water evaporates
to form vapor at state 4, and the expansion of this vapor raises the droplets to the
top of the mist generator at state 5 against the force of gravity. When the flow
reaches the top, it is turned radially outward to the condenser where cold water at
state 11 is sprayed into the flow to condense the vapor. Then the mixed flows at state
6 are discharged at state 7 to the ocean at a depth where their temperature matches
the local ocean temperature in order to minimize the environmental impact and to
prevent the used water from being recirculated through the plant. Cold deep
seawater at state 8 is drawn into the cold-water pump at state 9. Noncondensable
gases are drawn from the direct-contact condenser by the deaeration pump at state
12 to the atmosphere.
Analysis (Charwat, 1978) of the mist lift process and the entire cycle is
rigorously described by the conservation of mass and energy, and momentum
equations. They are
OPEN-CYCLE OTEC 253
where the subscript r is the reference state chosen for convenience; H0 is the
stagnation enthalpy; H is the enthalpy; h is the vertical height; V is the average
velocity; A is the cross-sectional area; v is the specific volume; m is the rate of mass
flow; and p is the pressure of a state.
The two-phase mixture is assumed to be in thermodynamic and dynamic
equilibrium. It is completely described by three properties: either (v, H, p) or H0,
vr, x), where x is the quality of the mixture.
Mechanical shaft work, which can be extracted from the water of high
potential energy by a hydraulic turbine, between a heat source temperature TH and
a condensing temperature Tc is expressed as
The theoretical specific work in the unit of water lift height for warm seawater
at 25C as a function of condensing temperature is shown in Figure 5-22. For a
condensing temperature of 10C, the theoretical lift height is 165 m.
a distance of 200 m by the conversion of its thermal energy into work. The warm
ocean surface water enters through the filter and then descends to the water turbine
to produce power. Low-pressure warm water is sprayed upward into the bottom of
the duct. The bottom 20 m of the duct comprises the mist acceleration zone. Cold
water is introduced into the accelerated mist in the form of a circumferential
converging sheet in the coast zone, which is also the condenser. A vacuum pump
removes noncondensables at the top. The pressure difference between the start and
the end of the acceleration zone drives the mist to a velocity of nearly 50 m/s. The
converging cold-water sheet merges with the accelerated mist to form a single jet,
which coasts upward against gravity and overflows into a basin from which it then
drains into the ocean. The reference characteristics of the plant and losses expected
in the mist flow process are listed in Table 5-3 and Table 5-4, respectively.
The details of the characteristics and losses are discussed by Ridgway and
Hammond (1978), Charwatetal., (1979), and Wallisetal. (1980). The powerplant
design is based on the results of an experimental mist lift cycle at UCLA (Charwat
et al., 1979).
The major findings in the experiments of Lee, Ridgway, Charwat, and
Hammond have verified the mist lift theory and demonstrated that water droplets
(200 fjim diameter) could be lifted to substantial heights (50 m) by their own vapor
produced in flashing over temperature differences typical of the tropical seas. The
coupling between the vapor and droplet was found to be excellent. These results
imply that a larger extrapolation mist flow OTEC power plant could be designed
(Lee and Ridgway, 1983) and built. Because the mist lift cycle is a relatively new
concept, further research and development efforts are needed to verify its potential
for OTEC power.
The net cost comes in at a little under $1000/kW (1978 value), which is very
low compared to that of the closed and open cycles previously discussed. The costs
quoted by Ridgway (1977) and Charwat (1978), however, seem to be lower-end
estimates.
5.5.1 Concept
A foam is defined as a mixture of liquid and vapor in which the overwhelming
volume percentage is in the vapor phase. The overwhelming mass percentage is in
the liquid phase, and the vapor is contained in cells bounded by liquid films.
The Beck, mist, and foam lift systems operate upon the same thermodynamic
principles, which can be shown on the T-S diagram (Fig. 5-24).
256 OCEAN THERMAL ENERGY CONVERSION
Table 5-3. Reference characteristics of 10-MWe mist flow ocean thermal plant
Warm-water temperature (C) 25
Cold-water temperature (C) 5
Injection nozzle diameter (cm) 0.01
Injection nozzle velocity (m/s) 20
Ratio of cold- to warm-water flow 3:1
Mixed-water temperature (C) 15
Droplet size (cm) 0.02
Hull diameter at surface (in) 60
Depth at juncture of hull to cold-water conduit (m) 200
Displacement (metric tons) 189,000
Freeboard to upper deck level (m) 25
Structure weight (metric tons) 50,000
Equipment weight (metric tons) 10,000
Ballast (metric tons) 129,000
Warm-water intake flow (metric tons/s) 13
Filter area (m 2 ) 130
Cold-water intake flow (metric tons/s) 39
Cold-water conduit diameter (m) 7
Cold conduit depth (neutral buoyancy pipe) (m) 1 ,500
Pumping load (kWe) 2,500
Housekeeping electric load (kWe) 1,000
Turbine-generator gross rating (kWe) 14,000
Net output (kWe) 10,000
Mist and foam lift are two types of single-exhaust OTEC systems. The liquid
and vapor phases in the two-phase region may be distributed either having droplets
of water in a continuous vapor phase (mist) or having bubbles of vapor in a
continuous liquid phase (foam). The enthalpy released by the warm water in
process AC may also be changed either directly as potential energy (foam lift) or
as kinetic energy (mist lift). In the potential energy case, the water automatically
rises against gravity. The foam lift cycle proposed by Zener and Fetkovich (1975)
raises the liquid water first and then allows it to fall and releases its stored potential
energy to a hydraulic turbine. In contrast, the mist lift cycle discussed in the last
section let the warm water first fall into a deep hole to convert the released energy
directly into kinetic energy; the kinetic energy is then transformed into useful work
by an impulse turbine.
Several advantages of the foam lift (and mist lift) system over the conventional
OC OTEC and closed-cycle OTEC systems are (Zener and Fetkovich, 1975):
1. Closed-cycle double-exhaust OTEC plants require heat exchangers. These
constitute a major cost of such plants. Single-exhaust systems have no heat
exchangers.
2. Open-cycle double-exhaust systems require power production by a very low
vapor pressure turbine. In contrast, single-exhaust OTEC systems require only
high head hydraulic turbines. Hydraulic turbines are less expensive per unit
power output than very low pressure vapor turbines.
3. All double-exhaust OTEC systems eject slightly chilled warm water. Special
care must be taken to avoid this warm exhaust water being sucked back into
the warm-water intake.
258 OCEAN THERMAL ENERGY CONVERSION
FIG. 5-25. Schematic diagram of a foam lift plant (Zener and Fetkovich, 1975).
OPEN-CYCLE OTEC 259
water at 5C [saturation pressure 0.87 kPa (0.126 psi)]. There is a flow of vapor from
the warm water (25C) to the condenser (5C). The water between 25 and 5C exists
as a foam. The flow of vapor from the warm region to the cool region is
accompanied by a flow of the whole foam structure. The foam structure consists of
the individual foam walls, the cell edges where two walls meet, and the cell corners.
The liquid and vapor can be separated by the foam breaker at the top of the tower.
The liquid is channeled into the central water column, where it is used to drive the
turbine and then discharged back into the sea.
A maximum lift height of 296 m (972 ft) is attained only when the available
enthalpy is completely converted into potential energy. Under this condition, the
foam would rise with a zero velocity and, hence, does not produce any power. The
maximum power per unit horizontal area is generated (Zener and Fetkovich, 1975)
at 17.4 kW/m2 (1.62 kW/ft2) when the foam breaker is at two-thirds of its maximum
height, 197 m (648 ft). The time required for the foam to reach the foam breaker at
197 m is 21 s. However, surfactant (e.g., Neodol) at a concentration of the order of
200 ppm is required to create a stiffer foam to prevent premature rupture during the
lift process, and antifoaming chemicals may be required to break the foams in the
condenser. Effects of the chemical additives upon the operating cost and the
environment are unique to the foam lift power system and will have an important
bearing on the success of this concept.
FIG. 5-26. A conceptual 1000-MW foam lift OTEC plant design (Zener and Fetkovich, 1975).
cell walls and cell corners. This close tie-in is destroyed by the foam breaker. The
liquid runs down into standing pipes and thence through the hydro-turbine. The
freed vapor descends the pathway into the condenser. The condensation of this
vapor somewhat warms the cold water entering the spray. Together they leave the
spray chamber to join the exit water from the turbines. This exit water is directed
through a pipe that ends above the level where the ocean temperature matches the
temperature of the exiting water.
Based on a temperature differential of 20C (from 25 to 5C) and at maximum
power generated per unit of foam generator area condition, the design dome radius
is 295 m (970 ft). Allowing one-fourth of the area enclosed by the dome for the
condenser and three-fourths for the foam generator, the area is 206,000 m2
(2,217,000 ft2). The net system efficiency is estimated at 33% of its ideal efficiency.
This is lower than that of the closed cycle.
The basic costs of the concrete hull structure and power machinery (including
hydraulic turbine, generator, water pump, and vacuum pump) are estimated (Chen
and Michael, 1980) to be $ 131 and $ 135/kWe (1979 value), respectively. The cost
estimate is comparable to those of the closed- and the open-cycle systems.
OPEN-CYCLE OTEC 261
The whole assembly is surrounded by a shell (4), which allows the desired low
pressure to be maintained within it. The conceptual design shown in Fig. 5-27 is
independent of absolute dimensions.
The foam lift OTEC power plant is a relatively new concept. Further investi-
gation on technical issues includes (1) demonstration of stable foam lift flow
concentration in the order of 10 ppm or less, (2) development of size scale-up
relations, (3) handling of noncondensables, and (4) system and platform design to
verify its potential for OTEC power and industrial applications.
OTEC research prior to 1981 was directed toward large floating plant systems
that would provide power to islands, certain parts of the mainland, and large
plantships that produce energy-intensive products. Closed-cycle OTEC plants
were believed to be closer to commercial readiness. Open-cycle plants were thought
to have significant long-term potential but were less developed and thus offered less
potential for near-term production. Funding for OTEC development was curtailed
in 1980, and the limited funds available were shifted to longer-term research and
redirected from closed-cycle to open-cycle OTEC research. Current OTEC re-
search focuses primarily on assessing and solving the technological problems
leading to the development of land-based or near-shore open-cycle systems ranging
in size from 2 to 15 MW. Researchers are looking at ways to make OC OTEC plants
more efficiently by designing smaller plants that produce more power, using
smaller volumes of water, and incorporating less expensive materials and compo-
nents.
A number of recent discoveries (1983-1988) have enhanced the economic
prospects for the OC OTEC systems:
1. Plentiful and relatively inexpensive aluminum alloy can be used in lieu of the
more expensive titanium for making OTEC heat exchangers.
2. Cost-effective turbines for OC OTEC systems are being developed.
3. A flash evaporator with 97% efficiency has been developed to convert warm
seawater into low-pressure steam for use in an OC OTEC steam turbine.
4. Desalinated water has been produced by using the open-cycle process at
prototypical conditions.
5. A seawater supply system has been deployed to provide the warm and cold
seawater for OC OTEC electrical energy production, with a cold-water
mariculture option.
6. A direct-contact condenser used in OC OTEC systems has made significant
advances, with thermal effectiveness over 95% at OTEC operating conditions
being tested.
REFERENCES
Barr, R., W. Deucher, J. Giannotti, R. Scotti, J. Stadter, J. P. Walsh, and R. Weiss, 1980.
"Report of the Ad Hoc OTEC CWP Committee: An assessment of existing analytical
tools for predicting CWP stresses." Proc. 7th Ocean Energy Conf., Washington, D.C.,
June, 2, 14.5.
Barr, R. A., and P. Y. Chang, 1977. "Some factors affecting the selection of OTEC plant
platform/cold water pipe designs." Proc. 4th Annual Conf. on Ocean Thermal Energy,
New Orleans, La., March, V-l 1.
Bartone, L. M., Jr., 1978. "Alternative power systems for extracting energy from the ocean:
a comparison of three concepts." Proc. 5th Ocean Thermal. Energy Conversion Conf.,
Miami Beach, Fla., Feb., V-l 1.
Beck, E. J., 1975. "Ocean thermal gradient hydraulic power plant." Science, 189, 293.
Bell, K. J., 1983. "Heal exchanger evaluation for OTEC program." Department of Energy
Report, DOE/ET/20312-5, Feb.
264 OCEAN THERMAL ENERGY CONVERSION
Benedek, S., 1980. "Heat transfer at the condensation of steam on turbulent water jet."
International], of Heat and Mass Transfer, 19, 448.
Bharathan, D. P., 1981. "Measured performance of direct-contact jet condensers." AIAA
Second Terrestrial Energy Systems Conf., Colorado Springs, Col., AIAA-81-2594-
252-1437, Dec.
, F. Kreith, and D. Schlepp, 1984. "Heat and mass transfer in OC-OTEC condenser."
ASMS Trans. J. Heat Transfer Engineering, 5, 287.
, F. Kreith, and W. L. Owens, 1983. "An overview of heat and mass transfer in open-
cycle OTEC systems." Thermal Engineering Joint Conf. Proc., Honolulu, Hawaii,
March, 2, 301.
Block, D. L., 1984. Thermoeconomic optimization of OC-OTEC electricity and water
production plants. Florida Solar Energy Center Report, FSCE-CR-108-84, Sept.
Bobe, L. S., and D. D. Malyshev, 1971. "Calculating the condensation of steam with a cross-
flow of steam gas mixture over tubes." Teploenergetika, 18, 84.
Boot, J. L., and J. G. McGowan, 1974. Feasibility study of a 100-MW open cycle ocean
thermal difference power plant. National Science Foundation report, NSF/RANN/SE/
GI-34879/TR/74/3, Aug.
Brewer, J. H., 1979. "Land-based OTEC plantscold water pipe." Proc. Ocean Thermal
Energy for the 80's Conf., Washington, D.C., June, 1, 4B-5.
Brewer, J. H., J. Minor, and R. Jacobs, 1979. Feasibility design study, land-based OTEC
plants. DOE report, 600-4431-02, Jan.
Brown, C. E., and L. Wechsler, 1975. "Engineering analysis of an open cycle power plant
for extracting solar energy from the sea." Proc. 7th Ocean Energy Conf., Washington,
B.C., June, 1, 1.
Browne, R. D., andM. R. C. Bury, 1981. "Practicalities of concrete for OTEC applications."
Proc. 8th Ocean Energy Conf., Washington, D.C., June, 1, 117.
Bugby, D. C., A. T. Wassel, and A. T. Mills, 1983. "Bubble nucleation and growth in OC-
OTEC subsystems." ASME Transactions J. of Solar Energy Engineering, 105, 119.
Buglaev, V. T., M. M. Andreev, and V. P. Kleschevnikov, 1971. "Investigation of steam
condensation in the presence of air on a horizontal tube bank under vacuum conditions."
J. Thermal Engineering, 18, 19.
Charwat, A. F., 1978. Studies of the vertical mist transport process for an OTEC cycle. DOE
Contract No. EY-76-5-03-0034, Nov.
, P. R. Hammond, and S. L. Ridgway, 1979. "The mist transport cycle: Progress in
economic and experimental studies." Proc. 6th OTEC Conf., Washington, D.C., June,
8c-3, 1.
Chen, F. C., 1979. "A thermodynamic assessment of OTEC open-cycle power system."
Proc. 10th Annual Pittsburg Modeling and Simulation Conf., Pittsburg, Pa., April, 10,
921.
, and A. Golshani, 1982. "OTEC gas desorption studies." ASME Transactions J. of
Solar Energy Engineering 104, 35.
, and J.W.Michael, 1980. "Development of OTEC lift cycles."Proc. 7th Ocean Energy
Conf., Washington, D.C., June, 2, 16.1.
Coleman, W. H., D. F. Rodgers, D. F. Thompson, and M. I. Young, 1981. "OC-OTEC turbine
design." Proc. AIAA 2nd Terrestrial Energy Systems Conf., New York, N.Y., Dec., 2,
108.
Coons, K. W., 1957. Direct condensers. Engineering Experiment Station report, College of
Engineering, University of Alabama, Bulletin 3.
OPEN-CYCLE OTEC 265
Leninger, T. F., 1983. Mass transfer in round turbulent water jets. University of California
at LA report, UCLA-ENG-8309.
Lewandowski, A. A., D. A. Olson, andD. H. Johnson, 1980. OC-OTEC system performance
analysis. Solar Energy Research Institute report, SERI/TR-631-692.
, D. A. Olson, and D. H. Johnson, 1982. Open-Cycle OTEC System Performance
Analysis, SERI Research No. SERI/TR-631-692, Oct.
Litvin, A., and A. E. Fiorato, 1979. "Development of a light-weight concrete for OTEC cold
water pipes." Proc. 7th Ocean Energy Conf., Washington, D.C., June, 1, 4B-5/1.
McDermott, Inc., 1981. Conceptual design study: cold water pipe systems for shelf-mounted
OTEC power plants. DOE report, DOE/NOAA/OTEC-48.
Mills, A. P., C. Tan, and D. K. Chung, 1974. "Experimental study of a condensation from
steam-air mixtures flowing over a horizontal tube: overall condensation rates." Proc.
5th International Heat Transfer Conf., Toyko, Japan, 5, 20.
Nauf, F. E., 1976. "Economic aspect of OTEC." Proc. Joint Conf. on Sharing the Sun, Solar
Technology in the Seventies, Cape Canaveral, Fla., 393.
Ocean Thermal Corp., 1983. OTEC pilot plant conceptual design study. DOE contract,
DOE-AC01-82CE30716.
Ofer, S., 1983. Experimental study of evaporation from round turbulent water jets. UCLA
report, UCLA-ENG-8308.
Olson, D. A., 1981. Water flows from slotted pipes. DOE contract, AC02-77CH00178.
ORI, Inc., 1983. Analysis and summary of OTEC cold water pipe costs. DOE report, DOE/
NOAA/OTEC-42.
Panchal, C. B., and K. J. Bell, 1984. "Theoretical analysis of condensation in the presence
of noncondensible gases as applied to OC-OTEC condensers." ASMS winter annual
meeting, New Orleans, La., Dec.
Panchal, C. B., and K. J. Bell, 1987. "Simultaneous production of desalinated water and
power using a hybrid-cycle OTEC plant." ASME Transactions J. of Solar Energy
Engineering, 109, 156.
Panchal, C. B., and H. C. Stevens, 1986. "Apparatus for OC-OTEC heat and mass transfer
experiments at the seacoast test facility." Proc. 1986 Oceans Conf., Washington, D.C.,
Sept., 1,213.
Parsons, B., D. Bharathan, and J. Althof, 1984. "OC-OTEC thermal-hydraulic systems
analysis and parametric studies." Proc. 1984 Ocean Conf., Washington, D.C., Sept., 1,
370.
Parsons, B. K., D. Bharathan, and J. A. Althof, 185. Thermodynamic analysis of OC-OTEC.
Solar Energy Research Institute report, SERI/TR-252-2234.
Penney, T. R., 1984. Small scale OC-OTEC power systems. Solar Energy Research Institute
report, SERI/TR-252-2184.
, 1986. "Composite turbine blade design options for Claude OC-OTEC power sys-
tems." 5th International Symp. and Exhibit on OMAE, Tokyo, Japan, April.
, and J. A. Althof, 1985. "Measurements of gas sorption from seawater and the influence
of gas release on OC-OTEC system performance." 1985 Solar EnergyThe Diverse
Solution Conf., Montreal, Canada, June.
, D. Bharathan, J. Althof, and B. Parsons, 1984. "OC-OTEC research: Progress
summary and a design study." ASME winter annual meeting, 84-WA/SOL 26.
Ridgway, S. L., 1977. "The mist flow OTEC plant." Proc. 4th Annual Conf. on Ocean
Thermal Energy, New Orleans, La., March, VIII, 37-4D.
, and P. R. Hammond. 1978. Mist flow ocean thermal energy process. R & D Associates
Report No. RDA-TA-107800-002, Sept.
OPEN-CYCLE OTEC 267
, R. F. Hammond, and C. K. B. Lee, 1980. Mist flow ocean energy thermal process.
Oakridge National Laboratory Report No. ORNL-7613/1, Apr.
Rogers, L. J., R. J. Hays, and A. R. Trenka, 1989. "A status assessment of OTEC technology."
Proc. EEZ Resources: Technology Assessment Conf., Honolulu, Hawaii, Jan., 6.32.
Rosard, D. D., 1978. "Working fluids and turbines for OTEC power systems." Proc. Fluids
Engineering in Advanced Energy Systems Conf., San Francisco, Cal., Dec., 229.
Saha, P., 1979. "A review of condensation of steam on subcooled water jets." NRC/RSR
Condensation Workshop, Silver Spring, Md.
Sam, R. G., and B. R. Patel, 1982. OC-OTEC evaporator/condenser test program data
report. Creare R & D, Inc., report, TN340.
, 1984. "An experimental investigation of OC-OTEC direct-contact condensation and
evaporation processes." ASME Transactions J. of Solar Energy Engineering, 106,120.
Science Applications, Inc., 1979. OTEC modular experiment: cold water pipe system design
study. DOE contract, DOE/NOAA/OTEC-15.
Sklover, G. G., and V. G. Grigorev, 1975. "Calculating the heat transfer coefficient in steam
turbine condensers." Teploenergetika, 22, 67.
Solar Energy Research Institute, 1983. Demisters for potable water production for open-
cycle OTEC systems. Solar Energy Research Institute report, SERI/TR-252-1991.
Trimble, L. C., 1975. "OTEC systems study report." 3rd Workshop on Ocean Thermal
Energy Conversion, Houston, Tex., May.
TRW Systems and Energy Group, 1979. Ocean thermal energy conversion cold water pipe
preliminary design project. DOE report, DOE/NOAA/OTEC-14.
Wallis, G. B., et al., 1980. "A computer model for the mist lift process in an OTEC open cycle
system." 11 th Annual Pittsburgh Conf. on Modeling and Simulation, Pittsburgh, Pa.,
May.
Wassel, A. T., and S. M. Ghiaasiaan, 1985. "Falling jet flash evaporators for OC-OTEC."
Int. Comm. Heat and Mass Transfer, 12, 113.
Watt, A. D., F. S. Matthew, and R. E. Hathaway, 1978. "Open cycle energy conversion
a preliminary engineering evaluation." Proc. 5th Ocean Thermal Energy Conversion
Conf., Miami, Fla., Feb., VII, 13.
, 1977. Open cycle energy conversion, a preliminary engineering evaluation. Colorado
School of Mines report.
Westinghouse Electric Corp., 1978. 700 MW OTEC alternative power systems. DOE
contract report, EG-77-C-03-1473.
Zener, C., and J. Fetkovich, 1975. "Foam solar sea power plant." Science, 180, 294.
6
OTEC CLOSED-CYCLE ENGINEERING STATUS
Engineering analyses and component design studies during the period 1974-1977
indicated the feasibility of constructing and operating floating OTEC plants and
plantships in a variety of configurations ranging in power from 40 to 500 MWe. In
August 1979, an at-sea test of a complete OTEC power system (Mini-OTEC)
demonstrated performance in good accord with engineering predictions and estab-
lished a firm basis for scale-up to larger sizes (Owens and Trimble, 1980). Heat
exchanger operation at a level equivalent to 1-MWe power generation was
demonstrated 1 year later in the OTEC-1 program. In 1981, a complete land-based
OTEC power plant was constructed and operated under Japanese direction at the
island of Nauru on the equator in the mid-Pacific ocean.
During the period 1977-1980, a U.S. plan was developed, supported by public
laws PL 96-310 and PL 96-320, to demonstrate OTEC feasibility at a 100-MWe
level by 1985 and 500 MWe by 1990. Testing was to start with a pilot demonstration
at 40 MWe (net). Preliminary design of baseline demonstration plants at this power
level for moored operation off Punta Tuna, Puerto Rico, and for grazing operation
west of equatorial Brazil with on-board ammonia production was completed in
1980 (George and Richards, 1980). Conceptual designs of larger plants and power
systems for demonstration at the baseline level were also completed.
In accord with the requirements of the Congressional actions, a Program
Opportunity Notice (PON) was issued in September 1980 by DOE that offered cost-
sharing support for innovative OTEC systems designs that contractors believed
would be commercially viable if government cost sharing were made available
during development of demonstration vessels. The PON asked for proposals for a
development program to design, construct, and test a 40-MWe (net) closed-cycle
OTEC system, which would be conducted in six phases beginning with conceptual
design and continuing to preliminary design, engineering design, construction,
deployment and operation, and, finally, transfer of ownership and contractor
operation. The schedule was set to be consistent with the goal established by PL-
96-310 of demonstration of 100-MW OTEC operation by 1985. DOE stated its
intent to fund five to eight awards for the first phase, with DOE providing $900,000
as its share of each contract awarded (Dugger el al., 1983).
Responses to the PON were received by DOE from eight contractor teams.
Summaries of the proposals, which contained proprietary material, arc presented in
Section 6.3.5. Part of the material has been made available to the authors by the
OCEAN THERMAL ENERGY CONVERSION 269
of the equipment can be installed at the dry dock. Most of the remaining equipment
will be installed after the hull is floated from the drydock to a nearby pier where the
water is deep enough to accommodate the desired draft. A schematic of this
procedure is shown in Fig. 6-1 (George and Richards, 1980). The platform is then
towed to a suitable deep-water area near the operational site, where the cold-water
pipe is installed. A facility for construction of a concrete or plastic CWP is built at
this location to avoid the need for a long sea journey by the CWP.
FIG. 6-1. Schematic of OTRC platform construction (George and Richards, 1980).
OCEAN THERMAL ENERGY CONVERSION 271
6.2.7 Shipyards
The discussion in this section applies only to floating OTEC platforms. Facilities
for land-based plants are site specific to the local terrain and construction capabili-
ties. Shipyards in the United States suitable for construction of OTEC vessels were
surveyed in 1978 in connection with the OTEC 40-MWe baseline design program
(George et al., 1979). The basic requirements defined were for a graving dock of
width exceeding 50 m and length over 150 m, along with supporting facilities that
would permit construction of a fully outfitted concrete platform. With heat
exchanger wells closed and without the CWP, the required draft is approximately
12m. The characteristics of shipyards throughout the world are available in the
Directory of Shipowners, Shipbuilders, and Marine Engineers (Motor Ship Press,
1988) and in Lloyd's Maritime Directory (Lloyd's of London Press, 1988). The
candidate U.S. shipyards that were identified will be discussed briefly here.
1. Newport News Shipbuilding Co., Newport News, Virginia: The shipyard is a
large complex with multiple shipbuilding ways and drydocks. Of particular
interest is a graving dock that is 490 m X 76 m X 13.4 m depth and is served
by an 870-tonne gantry crane. The shipyard is equipped for steel ship construc-
tion, but the management expressed interest in expanding the facilities as
needed for construction of OTEC vessels of the concrete barge design.
2. Avondale Industries, Inc., Avondale Shipyard Div., New Orleans, Louisiana:
Avondale'smain shipyard has three outfitting docks with supporting shops and
over 1800 m (6000 ft) of pier space. The upper yard has two large positions that
can accommodate vessels up to 311 m in length by 53 m beam. Part of one ship
can be constructed at position #1 while a second part is being built at position
#2. The parts can be moved laterally for final assembly.
3. Concrete Technology Corporation (CTC), Takoma, Washington: Concrete
Technology is a world leader in construction of marine structures based on
reinforced and post-tensioned concrete. Its shipyard includes a graving dock
that is 156 X 9 X 3.7 m (510 X 160 X 12 ft) and an outfitting pier with water
depth of 9.1-10.7 m (30-35 ft). Concrete Technology built and outfitted the
ARCO LPG concrete barge, of approximately the same dimensions as the
baseline 40-MWe OTEC design. The lower part of the hull of the ARCO barge
was constructed in the graving dock, after which it was floated out and
stationed next to the pier where construction and outfitting were completed.
Construction of the OTEC demonstration vessel at this facility would involve
minimal technical and financial risk.
4. National Shipbuilding (NS), San Diego, California: National Shipbuilding has
a large facility with ship ways of suitable size for OTEC ship construction.
There is no graving dock, but construction could be done in one of the shipways
that have a depth of 3.7 m (12 ft). Water depth at the outfitting dock is 8.5 m
(28 ft). This might require construction in three phases.
5. Hawaii: There is no commercial graving docks or shipways in Hawaii that
would be suitable for OTEC hull construction; however, there are large-scale
concrete and steel construction capabi lities in Hawai i that could support OTEC
272 OTEC CLOSED-CYCLE ENGINEERING STATUS
platform construction if a graving dock and pier were installed. It appears that
unused facilities at the U.S. Navy Pearl Harbor shipyard could be made
available if Federal support for commercial development of OTEC emerged,
reflecting world concerns about fossil fuel resources and global warming.
Shipyards in Germany, Spain, Portugal, Japan, and Korea that have graving
docks and berths large enough for construction of vessels exceeding 500,000 dwt
are listed here. These and many other smaller shipyards would be obvious
candidates for construction of commercial-size OTEC platforms:
Howaldswerke-Deutsche Werft (HDW), Kiel, W. Germany
Division de Constructione Naval (DCN), Madrid, Spain
Setanave-Estaleiros Navas de Setubal, Setubal, Portugal
Hitachi-Zosen Ariake Works, Osaka, Japan
Kawasaki Heavy Industries Ltd., Kobe, Japan
Hyundai Heavy Industries Co., Ltd., Kyung-nam, S. Korea
that rust particles from the hull could be trapped on the heat exchanger surfaces.
This could induce pitting and perforation of the aluminum separating surfaces.
5. Aluminum and titanium are too expensive to be considered as construction
materials for the OTEC platform.
6.2.2.2 OTEC Hull Construction
The extension of concrete technology from construction of small barges to a size
useful for OTEC was demonstrated in 1976 in the construction of the 145.5-m-long
ARCO barge, by Concrete Technology Corp. and AB AM engineers of Takoma,
Wash. A feature of the design was the use of post-tensioning of the concrete to
maintain the entire structure under compression at all operating conditions. Full
details of the project are presented in Mast (1975) and Anderson (1977).
The vessel was designed to store liquefied propane and butane produced 3.2
km (20 miles) offshore near Jakarta, Indonesia, in an area where land is marshy and
unsuitable for construction of land facilities. The complete vessel, equipped to
liquefy and store 375,000 barrels of LPG for periodic transfer to tankers, was
designed, constructed, and outfitted in Takoma during a 26-month period. It was
then towed 15,000 km to the Indonesia site where it has been in use ever since. Final
weight of the vessel was 59,000 tonnes. Nine thousand cubic meters of concrete
were used in the construction. Overall dimensions of the hull are as follows: length,
140.5 m (461 ft); beam, 41.5 m (136 ft); depth, 17.2 m (56 ft) (Mast 1975). A
photograph of the completed vessel en route to Indonesia is shown in Fig. 6-2 (Mast,
1975).
The ARCO barge was constructed in two stages. The first section of the hull
was built in the Concrete Technology graving dock: 170 m long, 50 m wide, and
3.65 m depth. This section was then floated, moved out of the dock, and anchored
next to a pier where water depth of 11 m was available. The upper sections were then
completed.
The vessel design satisfies all requirements of the American Bureau of
Shipping (A.B.S.) and related international agencies for safe operation on the high
seas, with a safety factor of two on the ultimate load, including ability to withstand
the worst stresses expected for the 100-year storm.
The design of the hull for the baseline 40-MWe OTEC demonstration vessel
is based directly on the ARCO barge technology. The dimensions are nearly the
same: length, 135.2 m (443.5 ft); beam, 42.7 m (140 ft); depth, 27.1 m (89 ft). Thus,
construction risks will be minimal for the demonstration vessel and will provide a
firm base for scale-up to sizes suitable for commercial OTEC vessels that will
operate with minimum maintenance for the 30-year design life and beyond.
The concrete selected in the baseline design study for the OTEC platform is
of normal weight, reinforced with steel bars of 414 MPa (60,000 psi) tensile strength
[276 MPa (40,000 psi) where welding is necessary], and prestressed using 1860-
MPa (270,000 psi) strands of 1.27 cm (0.5 in.) diameter, bundled in ducts. The
design compressive strength is 41.4 MPa (6000 psi) (George et al., 1979).
274 OTEC CLOSED-CYCLE ENGINEERING STATUS
The use of concrete for suspended OTEC CWPs introduces several design
requirements not present in standard concrete pipe structures:
1. The pipe must have longitudinal strength to withstand the weight of the pipe
in seawater. This requirement is met by using concrete of lower than normal
density and by post-tensioning the concrete to 41 MPa (6000 psi).
2. It is desirable to select a pipe weight that will ensure that the angle between the
pipe and the platform will not exceed allowable values in storm or grazing
conditions, and will also be compatible with the maximum load specifications
of the pivot joint. These requirements can be met by making the pipe of low-
density concrete weighing about 1350 kg/m3 (85 lb/ft3). (The density of
seawater is 1025 kg/m3.) The submerged weight is then 325 kg/m3. Concrete
with this density is made by using a low-density granular material to replace
the sand used in standard concrete. Flyash or various proprietary materials are
suitable (O'Connor, 1981).
3. As shown in Section 4.2, the bending moments would be excessive for a con-
crete CWP without flexible joints along the length of the pipe. Systems en-
gineering indicates that a pipe made of segments connected by flexible joints
at approximately 15-m intervals would be optimal for on-land construction,
transport to the floating platform, and deployment of the (oversized) 9.1 -m-dia-
meter concrete CWP for the 40-MWe baseline OTEC plantship (Paulling, 1980).
These considerations led to selection of the pipe design shown in Fig. 6-4 for
the baseline 40-MWe OTEC vessel (George and Richards, 1980). This design is
suitable for OTEC power plants of power levels up to 60-80 MWe (net). The design
is firmly based on experience in the construction of concrete structures by AB AM
Engineers, Inc., Concrete Technology, and the Portland Cement Institute (Mast,
1975; Cichanski and Mast, 1979; O'Connor, 1981).
The post-tensioned concrete technology developed for the ARCO barge is
directly applicable to the construction of the 9.1-m-diameter CWP chosen for the
40-MWe baseline OTEC barge and for engineering design of larger sizes. The
feasibility of using post-tensioned concrete to satisfy the specific design require-
ments of the joined OTEC design was demonstrated by construction and test to
failure of a 1/3-scale section of a CWP including a flexible joint of the proposed
design. The test section was 3 m (10 ft) in diameter and 5 m (16.4 ft) long, including
the flexible joint. Failure occurred at 140% of the predicted maximum stress for the
100-year storm. The test section was designed by ABAM and was constructed on
time and within the projected cost by Concrete Technology production employees
using their standard procedures. Details of the test are given in O'Connor (1980).
The test arrangement is shown in Fig. 6-5.
The pipe is made by casting 9.1 -m-diameter by 15.2-m-long concrete sections,
incorporating structures at the two ends for the bayonet-type locking mechanisms
and bearing pads for the flexible joint. Details of a typical CWP segment are shown
in Fig. 6-6. After curing and outfitting, the sections are placed on a barge for delivery
to the OTEC platform where they are progressively joined together and lowered to
form the complete CWP.
OCEAN THERMAL ENERGY CONVERSION 277
FIG. 6-4. Schematic of CWP for JHU/APL 40-MWe OTEC barge (George and Richards, 1980).
FIG. 6-5. Setup design for test of 1/3-scale concrete CWP (O'Connor, 1980).
FIG. 6-6. Design of section of segmented pipe for JHU/APL OTEC CWP (George and Richards,
1980).
The estimated costs for manufacturing, deploying, and installing the FRP pipe on
the OTEC platform were approximately 20% higher than for the concrete CWP, but
could offer advantages in deployment procedures.
The TRW and SAI studies also examined elastomer and polyethylene CWP
constructions and concluded that they would be feasible to build and deploy. The
elastomer option was estimated to be 50% higher in cost than FRP but was judged
worthy of further consideration as an alternative to the FRP design because of
possible advantages in deployment. The cost of polyethylene appears to rule out this
option. Further details and additional references are available in TRW (1979) (see
also Gershunov et al., 1981).
280 OTEC CLOSED-CYCLE ENGINEERING STATUS
The economic promise of OTEC depends strongly on the use of heat exchangers
that offer significant gains in performance and cost in comparison with conven-
tional designs. Five types that offered promise to meet these criteria were demon-
strated in the test programs conducted by the Argonne National Laboratory (ANL)
during 19791981, as discussed in Section 4.1. A brief assessment of the facilities
that would need to be developed for manufacture of these heat exchangers is given
in Table 6-1. None of the types requires more than modest extension of current
technology for use in OTEC. The total requirements for new facilities, fabrication,
and predeployment testing are minimal for the Trane and folded-tube types. Further
information for specific development plans is given in Sections 6.4 and 6.5.
Lockheed Missiles and Space Div.: Systems integration. Design, build, operate, test
power plant. Dynamic analysis of CWP-platform system.
State of Hawaii: Obtain, operate, maintain the platform. Provide diver service.
Dillingham Corp.: Design, modify, deploy platform. Design, fabricate, deploy
CWP.
Alfa-Laval ESD: Provide HXs, instrumentation, testing.
Worthingham Pump: Provide seawater pumps.
Rotoflow Corp.: Provide turbine-generator.
Only 19 months were needed from the date of the initial go-ahead decision
until the Mini-OTEC experiment produced net power at sea. The entire program
was completed by using off-the-shelf equipment and materials and standard
fabrication techniques. A Navy hopper barge (YGN-70) loaned to the State of
Hawaii was modified to form the platform for Mini-OTEC. The general dimensions
were as follows: length, 32 m (105 ft); width, 10.3 m (33.9 ft); draft, 1.3 m (4.3 ft).
A photograph of the at-sea deployment is shown in Fig. 6-8 (Owens and Trimble,
1980).
The CWP was made by joining 11.6-m sections of high-density polyethylene
to formasingle pipe 0.56mID (1.84 ft), 0.61 mOD (2.00 ft), and 661 mlong (2170
ft). The characteristics are listed in Table 6-2.
The CWP was suspended from a buoy, and transfer of cold water to the ship
was via an underwater hose, as shown in Fig. 6-9. A special setup onshore was
needed for assembling and joining the sections of PVC pipe, but the process used
available materials and techniques, and proceeded as planned, on schedule.
Design characteristics of the power plant, which used Alfa-Laval plate heat
exchangers, are listed in Table 6-3.
The observed performance of the complete power system agreed closely with
the analytical predictions. For the nominal warm- and cold-water temperatures, the
282 OTEC CLOSED-CYCLE ENGINEERING STATUS
FIG. 6-8. Mini-OTEC deployed off Kea-hole Point, Hawaii (Owens and Trimble, 1980).
predicted isentropic power production was 93 kW; however, the efficiency of the
small geared-down turbine-generator was 56%, so that only 53 kW of gross power
was produced. Water and ammonia pumps and auxiliaries consumed 35 kW,
operating at roughly half the efficiency that would be available in larger, state-of-
the-art equipment. Thus, the net power output of 18 kW was in close agreement with
expectations.
The experiment demonstrated that the systems engineering requirements of
OTEC power system design, construction, and operation at sea were understood at
a small scale [93 kW (gross)] and that plans for construction of pilot-size OTEC
vessels could proceed with confidence (Trimble and Potash, 1979; Trimble and
Owens, 1980). Details of the construction, deployment, and test results are given
in the references cited.
OCEAN THERMAL ENERGY CONVERSION 283
FIG. 6-9. Schematic of Mini-OTEC at-sea deployment (Owens and Trimble, 1980).
The OTEC-1 program of the DOE was established to create an at-sea test facility
at a nominal 35-MWt heat loading for testing OTEC components and subsystems
of moderate size that could furnish heat exchanger operational information for later
demonstration of larger systems (Svenson, 1979). A deliberate decision was made
by DOE not to include a turbine, but to use an expansion valve to simulate the
pressure drop through the turbine (35 MWt would generate about 0.9 MWe if the
system incorporated a turbo-generator). After investigation of possible platforms,
a decision was made to convert a mothballed Navy T-2 tanker, Chepachet, to
become the test vessel. Global Marine, Inc., was given responsibility for ship
conversion and CWP construction and deployment, and TRW was assigned
responsibility for the power system design and installation.
Conversion of the vessel was done in the shipyard of the Northwest Marine
Iron Works in Portland, Oregon. Construction was completed in June 1980, and the
vessel arrived in Hawaii in July 1980. CWP construction, deployment, and
installation on the ship, now named SS Ocean Energy Converter, were completed
in December. The at-sea test began with operation of the seawater pumps on
December 13, 1980. Heat exchanger testing was conducted until March 27, 1981.
The planned 2-year program was terminated because the costs of supplying the
pumping and auxiliary power needs via diesel-fueled generators, and of maintain-
ing the ship's crew, could not be funded within the reduced fiscal year 1981 budget
(Castellano, 1981; Castellano et al., 1983). Layouts of OTEC-1 indicating the
arrangement of the installed equipment are shown in Figs. 6-10 and 6-11 (Svenson,
1979). The hull dimensions were as follows: length, 160 m (525 ft); width, 21 m (69
ft); depth, 12 m (40 ft). The displacement was 22,000 tonnes (24,200 tons). The
OTEC-1 test loop is outlined in Fig. 6-12 (Lorenz et al., 1981a, 1981b).
FIG. 6-12. OTEC-1 test loop (Lorenz et al., 1981a and 1981b).
The installation included one evaporator and one condenser, with water and
ammonia pumps and control equipment to permit ammonia to be circulated through
the system under conditions simulating OTEC HX operation. The turbo-generator
needed for OTEC power generation was replaced by the throttle valve shown in the
sketch.
The evaporator was constructed in two sections that could be operated
independently. The upper HX employed a bundle of plain titanium tubes, and the
bottom used a bundle of enhanced tubes of the Linde design. The HX was designed
to be tested in either a sprayed or flooded mode; however, time and funding
limitations prevented tests of the latter type. The condenser contained only plain
286 OTEC CLOSED-CYCLE ENGINEERING STATUS
tubes. The system was designed so that various biofouling control methods could
be evaluated, such as Amertap and chlorine. Design details of the evaporator and
condenser are shown in Fig. 6-13 (Lorenz et al., 1981a, 1981b; Snyder, 1980).
Since OTEC-1 was designed only as a heat exchanger test vehicle, no attempt
was made to simulate an operational CWP. Instead, a CWP was made by binding
together three 1.22-m-diameter (4-ft) polyethylene pipes to form the 670-m-long
FIG. 6-13. (a) Design of OTEC-1 evaporator (Lorenz et al., 1981a and 1981b). (b) Design of
OTEC-1 condenser (Lorenzet al., 1981aand 1981h).
OCEAN THERMAL ENERGY CONVERSION 287
(2200-ft) CWP. Details of the construction and deployment are depicted in Fig. 6-
14 (Gershonov et al., 1981). The pipe was supported at the platform by a gimbal that
allowed rotation of the joint through an angle of 30 degrees. The pipe was assembled
onshore and towed to the vessel mooring site off Kona, Hawaii. A thorough study
was made prior to deployment to define the loads expected and the procedures
necessary to avoid excessive pipe stresses or deflections. Deployment and opera-
tion of the buoyant pipe were accomplished according to plan and provided
valuable insight into the requirements for deploying the larger FRP pipes proposed
for actual OTEC use (Gershonov et al., 1981).
288 OTEC CLOSED-CYCLE ENGINEERING STATUS
MWe (net), to supply needed power at reasonable cost to the island grid, with
full support by the island utility.
3. The pilot plant would supply basic information for the design and development
of shore-based closed-cycle OTEC plants that could be sited at a larger number
of island sites and some continental sites in the tropical oceans.
4. Specific information would be obtained that is necessary for projecting to
higher power levels the feasibility and costs of CWP fabrication and deploy-
ment for land-based OTEC plants. Accurate data would be obtained on
pressure losses in cold-water flow, biofouling effects and remedial procedures,
and overall system performance and costs.
The island of Nauru is an elevated coral reef surrounded by a lagoon 50-150
m wide. At the plant site, the seabed is irregular from the shore to a depth of 50 m
and then slopes at a nearly constant angle of 40-45 degrees to 700-m depth. The
seabed is hard near the shore but then becomes porous; however, the bearing
capacity is adequate for seabed emplacements.
The experimental program included bathymetric surveys of the site, develop-
ment of procedures for constructing and deploying the CWP, construction of the
shore-based OTEC power plant, and intermittent plant operation for 1 year while
the operating parameters were varied and performance changes were documented.
6.3.3.1 Site
A plot of temperatures and currents versus depth at the site is shown in Figure 6-
16(Uehara, 1982).
FIG. 6-16. Profiles of temperature, current, and depth at Nauru OTEC site (Uehara, 1982).
OCEAN THERMAL ENERGY CONVERSION 291
FIG. 6-18. Deployment procedure for CWP installation (Mitsui et al, 1983).
The Nauru test was designed to provide accurate experimental data on the
performance of the complete power cycle, as well as to demonstrate total pilot-plant
construction and operation. The goals were all successfully accomplished. The
plant provided the first demonstration of land-based OTEC net power generation
and established a record for total net power production, at 31.5 kW. It also was the
first demonstration of OTEC power connection to a utility grid.
Details of the evaporator and condenser design and equipment arrangements,
and documentation of the test results are presented in papers of Mochida et al.
(1983) and Kawano et al. (1983).
Evaporator Condenser
Seawater flow (kg/s) 402.8 391.7
Seawater flow velocity (m/s) 2.0 1.97
Inlet/outlet temp. (C) 29.8/27.3 5.6/8.1
Pressure drop (m) 2.90 3.71
Freon flow (kg/s) 20.6 20.6
Freon temp. (C) 24.8 13.0
Effective HX area (m2) 371.4 437.6
Heat duty (kWt) 4024 3911
Overall U(W/m 2 C) 3000 2560
FIG. 6-19. Layout of the Japanese Mini-OTEC vessel (Uehara et al., 1980).
OCEAN THERMAL ENERGY CONVERSION 295
plate-fin heat exchangers) and water pumps were mounted on the research vessel,
which was attached to the float. A flexible pipe carried the cold water from the float
to the vessel. The power plant performance is documented in Table 6-6.
The PON was issued in compliance with Public Laws PL 96-310 and PL 96-
320, which called for demonstration of 100 MWe of OTEC power by the year 1985
and 500 MWe by 1990. Background material made available to potential contrac-
tors included the baseline 40-MWe OTEC system design prepared by JHU/APL;
the power plant design studies by Westinghouse, TRW, and GE; and the platform
and CWP investigations by Hydronautics, Gibbs and Cox, Lockheed, and Global
Marine.
Responses to the PON were received from eight teams representing major U.S.
organizations with a broad range of expertise in systems engineering, chemical
engineering, equipment manufacturing, power plant design, marine engineering,
and shipbuilding. Each response represented a substantial engineering design effort
carried out in the anticipation that DOE would award at least five contracts if the
material supplied contained the technical depth expected, displayed innovative
concepts, showed reasonable management capabilities, and offered roughly 50%
cost sharing.
The proposals are briefly described in the following paragraphs abstracted
from Dugger et al. (1983).
1. General Electric (GE), as the system integrator, proposed a 40-MWe (net) plant
on an offshore oil-rig-type tower in 100 m of water off Kahe Point, Ohau,
Hawaii, with an undersea power cable to shore. Further details are given in
Section 6.4.2.
2. Ocean Thermal Corporation (OTC) proposed a 40-MWe (net) plant on an
artificial island in 8.5 m of water off Kahe Point, Ohau, Hawaii, with an
overhead cable to shore. It would use the warm water discharged from the
Hawaiian Electric Company (HECO) 600-MWe oil-fired plant, mixed with
surface seawater, to enhance the OTEC warm-water inlet temperature. Further
details are presented in Section 6.5.2.
3. Puerto Rico Electric Power Authority (PREPA) proposed a 40-MWe (net)
OTEC power plant mounted on a steel tower in 70 m of water off Punta Tuna.
Available offshore oil-rig technology would be used in the construction.
Futher details are given in Section 6.4.3.
4. SOLARAMCO (The Solar Ammonia Company) proposed a cruising 40-MWe
OTEC plantship sited south of Hawaii that would produce ammonia for
shipment to Hawaii or other markets. It would provide test operational
information for four advanced 10-MWe power modules of types found
attractive in tests at the Argonne National Laboratory (ANL) of DOE and
include a state-of-the-art ammonia plant for evaluation of shipboard operation.
Further information is provided in Section 6.4.4.
5. Virgin Islands Water and Power Authority (VIPWA), with EBASCO as
systems integrator and J. R. McDermott and TRW as subcontractors, proposed
a 12.5-MWe plant on a shelf-mounted tower 1.5 km off St. Croix to deliver 10
MWe of power plus 190,000 m3 day of fresh water. The vertical, shell-and-tube
heat exchangers (with titanium tubes) would be submerged. Part of the
discharged cold water would be used for mariculture experiments. The
OCEAN THERMAL ENERGY CONVERSION 297
principal features of the proposed system are described in Jones et al. (1981).
The total installation cost was estimated at $141 million, and net annual
receipts were estimated at $34 million from the sale of electric power, fresh
water, and deep water for mariculture. The after-tax rate of return (IRR) was
estimated at 15%, making the concept potentially commercially viable. Sig-
nificant reductions in plant costs and increases in receipts would result from the
use of aluminum plate-type heat exchangers and improved water desalination
processes that have resulted from recent developments. A flow chart for the
process is shown in Fig. 6-20.
6. Ocean Solar Energy Association, with Sea Solar Power as the systems
integrator and General Dynamics and CEER of Puerto Rico as subcontractors,
proposed an OTEC electric power plant mounted on a steel semisubmersible
platform that would deliver power to shore by underwater cable from a site
offshore from Punta Tuna, Puerto Rico. The platform would be maintained in
position by vectoring the exhaust water plumes from the heat exchangers. The
plant would use innovative designs of the platform, heat exchangers, turbines,
and CWP to achieve minimal weight and cost.
7. Commonwealth of Northern Marianas Islands (CNMI), with Science Appli-
cations, Inc., as systems integrator and Dillingham/Hawaiian Dredging, Burns
& Roe, and Global Marine Development, Inc., as subcontractors, proposed a
10-MWe plant on a concrete barge to be installed on a foundation 100 m off
Saipan, with overhead cables to the island grid. It would use a 4.9-m-diameter
CWP, with the upper 300 m made of concrete mostly trenched and buried. The
last 1300 m would be of FRP installed on bottom-mounted piers.
FIG. 6-20. Flow chart for the VIWAPA OTEC pilot plant (Jones et al., 1981).
298 OTEC CLOSED-CYCLE ENGINEERING STATUS
At completion of the Phase I work, this program was funded to continue to Phase
II, preliminary design. It is discussed in Section 6.5.2.
The following discussion is based on the final report on the GE Phase I contract
(General Electric, 1983).
Firms participating in the Phase I contract included:
General Electric Company: Systems engineering and direction.
Brown and Root Development, Inc. : Tower, CWP, seawater piping.
Trane Corp.: HX and manifolding.
Worthington Co.: Pumps.
Hawaiian Electric Co. (HECO): Land-based facilities.
The GE OTEC design is based on the use of a tower-mounted OTEC plant
installed 2200 m offshore at a depth of 100 m, at Kahe Point, Oahu, Hawaii. Power
produced at the OTEC platform is carried by underwater cable to the Hawaiian
Electric Company (HECO) plant for distribution to its customers.
An artist's sketch of the tower and a schematic drawing are shown in Fig. 6-
21. Cold water is supplied through a pipe made of steel pipe sections 8.5 m in
diameter, 150 m long, connected end to end and extending along the sloping sea
bottom for 2000 m, to a depth of 670 m. The pipe-laying sequence is depicted in Fig.
6-22. The GE concept involves tradeoff and optimization studies of siting options,
OCEAN THERMAL ENERGY CONVERSION 299
FIG. 6-21. GE tower design for OTEC offshore plant (General Electric, 1983).
tower designs, CWP design and deployment, heat exchanger selection, turbo-
generator and water pump sizing, and power generation and distribution. Proce-
dures for biofouling control and component maintenance and replacement were
investigated, and optimal arrangements were defined. Only the final concept is
discussed here.
The GE concept calls for the tower to be constructed onshore and then barged
to the offshore site, where it is erected by using procedures and equipment in
common use for emplacement of offshore oil-drilling rigs. The tower is designed
for convenient transfer of the power plant components to and from their mounting
positions on the tower, via built-in elevators, semi-automated underwater transfer
equipment, and derricks. Thus, pumps and heat exchanger modules may be blocked
off, moved to the main deck for servicing, and returned without total plant
shutdown. Cold water from the 8.5-m-diameter CWP enters a manifold near the
base of the tower, where it transfers to four 5.9-m-diameter pipes before being
routed to the condenser modules. Each pipe incorporates a pump operated by an
external motor sealed for underwater operation. Each pipe is routed to serve four
condenser modules. Warm water is drawn from a manifold mounted at a depth of
15 m equipped with 12 stainless steel screens, each 9 m X 1 2 m . Eight 4.7-m-
diameter pipes conduct the water to 8 pairs of evaporator modules mounted at the
79-m level. Elevation views of the piping systems for the evaporators and condens-
ers are shown in Figs. 6-23 and 6-24.
300 OTEC CLOSED-CYCLE ENGINEERING STATUS
FIG. 6-22. Deployment procedure for GE OTEC plant (General Electric, 1983).
FIG. 6-23. Warm-water duct geometry for GE offshore electric plant (General Electric, 1983).
Frc. 6-24. Cold-water duct geometry for GE offshore OTEC plant (Gencral'Electric, 1983).
302 OTEC CLOSED-CYCLE ENGINEERING STATUS
Evaporator Condenser
Heat load (MWt) 1915 1871
Water flow (kg/s) 212,600 184,300
Ammonia flow (kg/s) 1533 1533
Overall heat trans, coeff. (W/m 2 K) 4528 4506
Fouling coeff. (W/m 2 K) 3.5 X 105 1.8 X 105
Water inlet/outlet temp. (oC) 25.56/23.33 4.94/7.49
Ammonia inlet/outlet temp. (o C) 1 0.33/2 1 .23 1 0.30/1 0.62
Seawater p (m)
Inlet pipe 0.51 2.61
HX 1.10 1.48
Seawater velocity (m/s) 1.45 1.60
Condenser flow [m3/MW (net)] 5.3
Net power/total HX area (kW/m2) 0.16
The principal features of the PREPA design are described in the following
subsections.
6.4.3.1 Platform
The tower mounting is selected to avoid the perceived problems of power transmis-
sion from a floating plant, and to avoid design uncertainties in the mooring and cold-
water pipe installations for a floating configuration. The platform design employs
steel construction and depends on design practice and technology developed for
offshore oil installations. A wide range of computer codes is available for establish-
ing static and dynamic specifications to withstand wave, wind, and current loads for
extreme hurricane conditions. A survey of the topography led to selection of a
sloping site 200 m offshore for platform emplacement near the edge of the
continental shelf. The slope and character of the sea bottom at the site implies the
304 OTEC CLOSED-CYCLE ENGINEERING STATUS
FIG. 6-26. Platform concept for PREPA OTEC plant (PREPA Phase I proposal, 1981).
need for drilling and grouting piles and some extension of existing off-shore
technology, but no major problems were foreseen to cause significant risk in the
installation. A scenario for platform installation is depicted in Fig. 6-28.
6.4.3.2 PREPA Power Plant
The power plant design employs four 10-MWe (net) modules that use shcll-and-
tubc heat exchangers with ammonia as the working fluid. The power plant turbines
and generators are mounted on the platform deck. The evaporators and condensers
are provisionally mounted at a depth of 15 m (to the top of the heat exchangers). This
OCEAN THERMAL ENERGY CONVERSION 305
FIG. 6-27. Topography of site for PREPA OTEC plant (PREPA Phase I proposal, 1981).
FIG. 6-28. Deployment procedure for PREPA OTEC platform (PREPA Phase I proposal, 1981).
FIG. 6-29. Power cycle for PREPA OTEC power plant (PREPA Phase I proposal, 1981).
OCEAN THERMAL ENERGY CONVERSION 307
generators, cranes, power conditioning and control systems, support facilities, and
personnel accommodations on the top deck.
Minimization of pressure losses required location of the water pumps and heat
exchangers below the surface. For minimum pressure losses in the ammonia
systems, turbineheat exchanger distance should be as short as possible. To avoid
excessive loads caused by wave action, underwater components should be placed
at a depth well below the top of the maximum significant wave.
Tradeoff studies then led to the layouts for the power system components
shown in Fig. 6-30.
6.4.3.3 Water Ducting
Fiberglass-reinforced plastic (FRP) was selected as the preferred material for the
CWP and the discharge pipes. The 8-m-diameter CWP, approximately 2000 m
long, would be deployed as shown in Fig. 6-31. Thre 8-m-diameter discharge pipes
emplaced in a suitable trench on the shelf were designed to conduct the mixed
effluent from the plant to a depth below the thermocline.
6.4.3.4 Energy Transfer
The design calls for power to be transmitted as 115 kV AC through an entrenched
power cable joining the bus bar at the platform to the onshore utility. Cables of the
required capacity are commercially available, and PREPA and Brown and Root
have extensive experience in laying and operating oil-filled cables of much larger
capacity. The design 10-MWe output at 13.8 kV of the four power modules would
feed into a single bus and then be stepped up to 115 kV to match the voltage of the
onshore substation.
The principal features of the PREPA 40-MWe (net) OTEC concept are listed
in Table 6-8. Estimated costs are listed in Chapter 7.
FIG. 6-30. Subsystem layout for PREP A OTEC power plant (PREPA Phase I proposal, 1981): (a)
side view; (h) front view.
OCEAN THERMAL ENERGY CONVERSION 309
FIG. 6-31. Deployment procedure for PREPA OTEC CWP (PREPA Phase I proposal, 1981).
operation off Kahe Point, Hawaii. In this way the same basic plant could provide
engineering design information for commercial-size OTEC operation in both
grazing and moored modes.
Participants in this PON response included:
SOLARAMCO: A company formed to develop, build, test, and operate a 115- ton/
day [40-MWe (net at busbar)] grazing OTEC ammonia plantship, and market
the ammonia product.
310 OTEC CLOSED-CYCLE ENGINEERING STATUS
Table 6-8. PREPA 40-MWe (net) OTEC electric power plant concept
Tower dimensions (steel construction)
Top platform: W 85 m, L 45 m; height above SL 20 m
Base: W90m,L 50 ma; depth (landside) 70 m, (oceanside) 100 m
Power plant
Closed Rankine cycle; ammonia working fluid
Shell-and-tube heat exchangers; titanium tubes OD 2.54 cm, ID 2.40 cm
Each 10-MW HX contains 3 bundles of 14,000 tubes
Evaporator tubes enhanced on shell side with Linde Hi Flux coating
Four 10-MWe (net) power modules
Evap: Diam. 11.3 m; L 13.3 m, 11 mb
Cond.:Diam. 11.3m;L20m, 17.7m b
Evaporators and condensers at 15-m depth (top)
Nominal operating characteristics
T22.5C; seasonal variation 2C
Gross power -53 MWe
Net power 40 MWe
Warm-water inlet temp, (o C) 27 2
Cold-water inlet temp. (C) 4.5 0.5
Overall U0 (W/m2 C): evaporator 4000, condenser 2800
Water ducts
CWP
FRP construction 8-m-diam., 2000-m-long, intake at 1000-m depth
Assembled by joining 10-m sections lowered from a surface ship
Emplaced via a marine rail
Mixed effluent: three 8-m-diam. pipes laid on shelf to 200-m depth
a
At 70-m depth.
b
Tube length.
FIG. 6-32. Proposed grazing area for SOLARAMCO ammonia plantship (SOLARAMCO Phase I
proposal, 1981).
OCEAN THERMAL ENERGY CONVERSION 311
FIG. 6-33. Design of SOLARAMCO ammonia plantship (SOLARAMCO Phase 1 proposal, 1981).
312 OTEC CLOSED-CYCLE ENGINEERING STATUS
FIG. 6-34. Construction and deployment sequence for SOLARAMCO plantship (SOLARAMCO
Phase I proposal, 1981).
FIG. 6-35. Diagram of power cycle for Alfa-Laval, Trane, and folded-tube HX systems (SOLAR AMCO
Phase I proposal, 1981).
FIG. 6-36. Di gram of power cycle for shell-and-lube HX (SOLARAMCO Phase 1 proposal, 1981).
314 OTEC CLOSED-CYCLE ENGINEERING STATUS
separating walls of 25-mm-thick FRP. The pipe is made in sections 10-20 m long
that are barged to the platform stationed at the final assembly site off Kahe Point,
Hawaii. Here the pipe is assembled by progressively joining and lowering the 10-
to 20-m sections through a moon pool in the hull. Pipe joint options are shown in
Fig. 6-37. A two-axis, in-plane gimbal (Fig. 6-38) provides a flexible connection
between the pipe and platform.
6.4.4.5 Exhaust Ducting
Warm- and cold-water effluents are discharged, unmixed, at the bottom of the heat
exchanger bays. Forward movement of the plantship prevents reinjection of the
discharged plumes into the warm-water inlets.
6.4.4.6 Energy Transfer
The net power available from the OTEC turbine-generators is used in water
electrolysis to produce hydrogen that is combined with nitrogen to form ammonia.
The ammonia is liquefied and stored on-board the grazing plantship for a nominal
1 -month period and is then transferred to an ammonia tanker for shipment to port.
The SOLARAMCO members then market the ammonia through their normal
commercial channels.
The principal characteristics of the SOLARAMCO Phase I design are listed
in Table 6-9. Estimated costs are summarized in Chapter 7.
FIG. 6-37. Alternative schemes for connecting FRP C WP sections (SOLARAMCO Phase 1 proposal,
1981).
OCEAN THERMAL ENERGY CONVERSION 315
FIG. 6-38. Gimbal for CWP connection to the SOLARAMCO OTEC plantship (SOLARAMCO Phase
I proposal, 1981).
1. Design of the power plant components for submerged operation so that the
major power plant components can be placed in the ocean outside the hull.
2. Use of turbine-driven pumps for the warm and cold water. This eliminates
efficiency losses in conventional designs that result from conversion of turbine
power to electric power for operation of electrically driven pump motors.
3. Use of a new heat exchanger design with projected heat transfer rate four times
that of conventional heat exchanger designs.
4. Use of a four-stage vapor cycle to improve the average temperature difference
between the water flows and working medium flow.
OCEAN THERMAL ENERGY CONVERSION 317
cables. The tube is made by binding together parallel steel tubes of about 1/3 m
diameter to create a cylindrical "stockade" configuration. The length of the tubes
is selected to permit assembly of pipe sections on the platform that can then be
joined together and lowered to form acomplete CWP of the desired total length. The
hollow tubes may be sealed and filled with air or water to control the buoyancy of
the assembly. The spring support is designed to isolate the CWP from platform
motions. Details of the support and water seal between pipe and platform have not
been published. The allowable angular motion between CWP and platform has not
been stated. Since the cold water is discharged into the mixed layer, it is expected
to enhance biomass production.
Warm Water. Warm water enters the system through the screens shown in
Fig. 2-3. The turbine-driven warm-water pumps are located in the vertical down-
comer pipes that conduct the water to the evaporator plenums.
Exhaust Ducting. Water from the evaporators and condensers discharges
directly through vanes into the surrounding seawater. Under average conditions the
water will enter the mixed layer and will be denser than the ambient water.
6.4.5.4 Energy Transfer
The design calls for electrical energy to be transferred ashore by an underwater
cable connecting the floating OTEC plant terminal to the onshore utility. The plant
is maintained in position by vectoring the exhaust flow to counter surface and
subsurface ocean currents. Similar methods are employed for stationkeeping of
semisubmersible drilling rigs; however, the thrust requirements are much larger
because of the underwater areas of the evaporators and condensers. Stationkeeping
must be possible under storm conditions that would cause loss of OTEC power,
implying a need for a method independent of the OTEC pumped water flow. The
method and costs of the standby equipment are not available.
6.4.5.5 Construction and Deployment
Construction of the OTEC plant, without the CWP, would be done in a shipyard
experienced in fabrication of oil drilling rigs. Deployment would involve support-
ing the OTEC structure on its side on a barge, towing the barge to the offshore site,
and then floating the assembly free from the barge and maneuvering it into an
upright position for assembly and installation of the CWP. Details of the deploy-
ment scenario have not been published.
ciently uses both oxygen and hydrogen produced by water electrolysis in combina-
tion with low-cost coal to produce a low-pollution liquid vehicle fuel that can
replace gasoline for transportation at competitive costs. Unlike other synfuel
processes involving coal as a feedstock, no CO2 is generated as a byproduct of the
OTEC methanol synthesis process.
The following organizations participated in the OTEC methanol conceptual
design program:
The Johns Hopkins University Applied Physics Laboratory (JHU/APL): Technical
direction and systems integration.
Brown and Root Development, Inc. (BARDI): Initial design of OTEC methanol
process and plant space requirements based on Texaco coal gasification and
Lurgi methanol synthesis. Hull sizing and seakeeping requirements for 160-
MWe (net) OTEC methanol plantship.
EBASCO Services, Inc.: Advanced design of OTEC methanol process based on
Rockwell coal gasification and ICI methanol synthesis.
Rockwell International: Design of coal gasification process (Kohl et al., 1980).
The principal features of the OTEC methanol conceptual design are discussed
briefly in the following sections.
6.4.6.1 Platform
The platform configuration is based on scale-up of the APL 40- MWe (net)
plantship to 160 MWe (nom) to provide power and space for a 1750-mt/day
methanol plant. The rectangular hull, with vertical sidewalk, is constructed of post-
tensioned concrete as in the baseline 40-MWe design. Wing walls at the sides and
ends provide longitudinal strength to resist 100-year-storm bending loads. Minimal
fairing of the bow is provided to reduce drag in grazing operation. The methanol
plant is placed at the center of the platform with OTEC power modules of 80 MW
(net), each equipped with a CWP, at either end. The layout is shown schematically
in Fig. 6-39. An outboard profile is shown in Fig. 6-40. For a 184-MWe power
output, enlargement of the baseline design of the cold-water pipes from 9.1 m
diameter to 11-13 m, with accompanying enlargement of the flexible joint
supports, is required. Power for seakeeping is provided by rotatable ducted thrusters
beneath the hull. Details of the design and analysis of the platform motions under
normal and storm conditions are provided in BARDI (1982). Platform construction
and deployment follow the procedures discussed in Section 6.5.1 for the APL 40-
MWe demonstration plantship, with appropriate modifications to accommodate
the larger size.
6.4.6.2 Power Plant
A plan view of the power plant layouts is included in Fig. 6-39. Eight 10-MWe (net)
power modules are grouped around one CWP at station 137.6 and eight around a
second CWP at station 687.5. (Note that the drawing dimensions are in English
units.) Each 10-MWe module includes two evaporators and two condensers,
supplied with seawater by gravity flow from overhead ponds, as in the baseline
320 OTEC CLOSED-CYCLE ENGINEERING STATUS
40-MWe OTEC design. The BARDI study uses the APL baseline power plant
performance based on the ATL-1 operational site and annual average Tof 23.3C
to give a nominal power output of 160 MWe (net) for their design. In the EB ASCO
update (EBASCO, 1984), a South Pacific site near Guam was chosen where the
annual AT is 24.1 C. A calculation of the power output for each month of the year
for this site shows that the annual average power of the nominal 160-MWe plant
would be 178.4 MWe (net), with maximum output of 189.9 MWe (net) in the
months of July and August. Since the turbines and generators would need to be
designed for this maximum output, EBASCO proposed that a supplementary coal-
fired boiler electric power system be installed that would be used to maintain
constant net power input of 189 MWe to the methanol plant. This modification
increases annual coal consumption by only 6%, with evident advantages in
maintaining plant efficiency at maximum levels throughout the year. The details are
presented in Table 6-10 (EBASCO, 1982). The added capital cost is small because
coal supplies and handling equipment are already available on the plantship.
A brief study by EBASCO indicated that the average net power could be
further increased to 207 MWe (net) in a thermal augmentation cycle that uses
process heat to superheat the ammonia working fluid in one or two of the OTEC
power modules, as shown in Fig. 6-41. The Mollier diagram for the process is shown
in Fig. 6-42. This modification was incorporated in estimating the methanol plant
output; however, funding was not available to permit equipment details of that
process to be established.
6.4.6.3 Water Ducting
The BARDI and EBASCO conceptual design studies were not funded to determine
the design requirements of the water-ducting systems for the 160-MWe (net)
methanol plantship. Scale-up of the 40-MWe baseline design, with improvements
suggested by the ANL experiments, indicates that two CWPs of 11-13 m diameter
made of FRP or lightweight concrete and supported at the center position on the
platform of each 80-MWe module by a universal joint or ball-and-socket mounting
will be required. The general layout is indicated in Figs. 6-39 and 6-40 (Avery et
al., 1983). No ducting is necessary for the warm- and cold-water effluents.
6.4.6.4 Energy Transfer
Energy transfer via production of methanol on an OTEC plantship with subsequent
shipment to world ports was studied in two phases. In the initial phase the feasibility
was studied of installing a methanol plant based on the Texaco coal-slurry coal
gasification process and Lurgi methanol synthesis (BARDI, 1982; Avery et al.,
1983). BARDI was selected for the design study because of their experience in
operating a demonstration of the Texaco technology at Muscle Shoals, Mississippi,
and the availability to them of a proprietary preliminary engineering design of a
barge-mountedplantforoffshoreproductionof methanol from natural gas. Both the
hull design requirements and methanol plant installation and operation were
considered. Further information was available from reports on the status of floating
vessels for industrial plants in a comprehensive study conducted by the U.S.
322 OTEC CLOSED-CYCLE ENGINEERING STATUS
FIG. 6-41. Augmented 20-MWe (nom) OTEC power cycle (EBASCO, 1982).
FIG. 6-42. Mollier diagram for proposed OTEC methanol power cycle (EBASCO, 1982).
324 OTEC CLOSED-CYCLE ENGINEERING STATUS
During the period 1974-1977 a program was established in Japan to explore the
feasibility and cost of supplying power or energy-intensive products to Japan via
OTEC. A presentation by Kamogawa to the Sixth General Meeting of the Pacific
Basin Economic Council in 1970 that suggested OTEC as a potential means of
supplying power and promoting mariculture led to the establishment in 1974 of a
committee of the Ministry of International Trade and Industry (MITI) to investigate
the feasibility of OTEC. The program was named the "Sunshine Project." In the
same year experimental work was begun at the Electrotechnical Laboratory of the
Agency of Industrial Science and Technology (AIST) in Tokyo, and at the Science
and Engineering Faculty of Saga University (Kamogawa, 1972; Homma and
Kamogawa, 1979). The program began with a first phase study of a 1-MWe, land-
based plant and proceeded to a study of a 100-MWe floating plant. This was
followed by a conceptual system design in 1975. In 1976 an improved conceptual
design was developed, and in 1977 the design was further refined with emphasis on
platform structure, stationkeeping, riser cable design, and heat exchanger improve-
ments. Only the final version is discussed here.
The following organizations participated in the conceptual design studies:
Saga University
Electrotechnical Laboratory
MITI
Tokyo Electric Power Co.
OCEAN THERMAL ENERGY CONVERSION 325
FIG. 6-43. Rockwell molten carbonate coal gasifier (Richards et al., 1984).
FIG. 6-44. Schematic of EBASCO-BARDI-Rockwell OTEC methanol power cycle (Avery et al.,
1985).
in some detail. The sites are shown in Fig. 6-45. An estimate of the total OTEC
power that could be produced from the thermal resources of the sea near Japan
indicated a potential output of 3.75 X 105 GW h/y from an area 1 wide in longitude
and 1 high in latitude. This output exceeds the annual electric power consumption
in Japan (Kamogawa, 1980). The sites at Toyama and Osumi were selected for
conceptual designs of OTEC moored plants. A summary of factors considered in
the conceptual design studies is listed in Table 6-11.
6.4.7.2 Platform
Three types of platform, all of steel construction, were considered: a surface ship,
a surface disc, and a submerged disc. After study of construction feasibility,
mooring, CWP design, requirements to meet extreme weather conditions, and
estimated capital cost, the submerged disc was chosen for evaluation at the Osumi
site, and the surface ship for the Toyama site. Both platforms are designed for
moored operation offshore Japan, with power transmission by underwater cable to
the on-land power system.
6.4.7.3 CWP and Power Transmission
Information is not available.
OCEAN THERMAL ENERGY CONVERSION 327
FIG. 6-45. Sites for proposed Japanese moored OTEC power plants (Homma and Kamogawa, 1979).
A feasibility study of shore-based and floating OTEC plants to be sited in Tahiti was
conducted during 1978-1980 under sponsorship of the French Centre pour
1'Exploitation des Oceans (CNEXO). It was concluded that, with estimated OTEC
plant costs and projected oil prices, OTEC installations of 520 MWe would be
competitive with oil plants. The favorable result led to a decision to proceed with
the design of a land-based 5-MWe OTEC power plant, with a scheduled completion
date of 1985. The Phase II program was initiated under joint sponsorship of
CNEXO (renamed IFREMER) and an industrial joint venture called EUROCEAN
GIE, composed of the companies that had been involved in the Phase I program. The
Phase II program included detailed site studies, evaluation of closed- and open-
cycle options, methods of constructing and deploying the cold-water pipe, and
estimates of costs of favored alternatives.
FIG. 6-46. Site of proposed French 5-MWe OTEC plant in Tahiti (IFREMER, 1985).
330 OTEC CLOSED-CYCLE ENGINEERING STATUS
The survey shows that a T"of 23.3 1.5C is available at a depth of 1000 m
within 3 km from shore and that the bottom slopes gradually from near shore to the
1000-m depth. The maximum wave is estimated to be 12m and the wave period
12s.
6.4.8.2 Platform
The design does not call for a platform or containment building. Instead the power
plant components are mounted separately. Plant layouts for closed-cycle and open-
cycle systems are illustrated in Figs. 6-47 and 6-48. A pond adjoining the power
plant installation receives nutrient-rich water leaving the condensers that is to be
used for mariculture programs. The water effluent streams are finally directed to a
lagoon from which the water flows to the ocean.
6.4.8.3 Power Plant
Conceptual designs of both closed- and open-cycle OTEC installations have been
prepared, based on selection of the most attractive of a wide range of alternative
designs considered in Phase I. Investment comparisons indicate that the costs of the
two systems are within 5% of each other. The closed-cycle plant uses horizontal
shell-and-tube heat exchangers with smooth titanium tubes in both evaporators and
condensers. A cost study showed that the performance gains with enhanced
surfaces would not compensate for the added cost of enhancement of the condenser
tubes. Dependent on industrial capabilities, enhancement of the evaporator tubes
could be cost effective (Marchand, 1985). A decision not to use aluminum was
based on the lack of data on the long-term durability of aluminum. [Durability has
FIG. 6-47. Layout of proposed French closed-cycle 5-MWc OTEC plant in Tahiti (IFRIiMER, 1985).
OCEAN THERMAL ENERGY CONVERSION 331
FIG. 6-48. Layout of proposed French open-cycle 5-MWe OTEC plant in Tahiti (IFREMER, 1985).
held at the base by concrete footings. At the knee the pipe connects through a
ball joint to the deep-water section.
2. The deep-water pipe is supported above the sea floor in a trajectory defined by
"hawses" anchored by piles in the sea floor and supported by buoys designed
to float at 50 m depth. The neutrally buoyant CWP, 3 m in diameter, assembled
on shore as deployment proceeds, is deployed by pulling it through the hawses.
This arrangement was selected after studies of the alternatives depicted in Fig.
6-50 (IFREMER, 1985; Geothermies Actualities, 1985).
3. Reviews of materials and methods for construction of the CWP led to selection
of a double-walled design with fiber-reinforced plastic (FRP) side walls and a
syntactic foam spacer.
6.4.8.5 Energy Transfer
Direct transmission of electric power, preparation of fresh water, and mariculture
may all be combined to make operation of the 5-MWe Tahiti plant of commercial
interest. Cost estimates for the last option have not been obtained.
The principal design features of the 5-MWe (net) Tahiti OTEC plants are listed
in Table 6-13. Cost information is presented in Chapter 7.
In 1984 the Taiwan Power Company initiated a program to determine the feasibility
and to prepare conceptual designs of shore-based 50-MWe OTEC plants in Taiwan
(Liao et al., 1986). Three sites on the east coast of Taiwan were selected for
evaluation: Ho-Ping, Shi-Ti-Ping, and Chang-Yuan. Studies of the bathymetry at
the sites, water temperatures and currents, and availability of supply and construc-
tion facilities led to the conclusion that shore-based plants at Ho-Ping and Chang-
OCEAN THERMAL ENERGY CONVERSION 333
FIG. 6-50. Alternative methods for 5-MWe CWP deployment (IFREMER, 1985).
Yuan sites should be selected for conceptual design. The locations are shown in Fig.
6-51. The design features are reviewed briefly in the following sections.
6.4.9.1 Platform
After reviewing estimated costs, it was decided that the platform (containment
structure) should be constructed in a shipyard, where facilities for installing heavy
equipment would be available. The platform would then be floated and towed as a
unit to the plant site on the beach. Here it would be lowered by flooding the sumps
334 OTEC CLOSED-CYCLE ENGINEERING STATUS
Table 6-13. Conceptual designs of French 5-MWe (net) OTEC plants at Tahiti
Closed-cycle plant Open-cycle plant
Platform Shore-based not enclosed Shore-based not enclosed
Power plant Closed Rankine cycle Open cycle
Evaporator Condenser
U0 (unenhanced) (W/m2 C) 2,000 2,200
HX area (m2) 32,000 50,500
Heat loading (MWt) 260 252
FIG. 6-51. Sites selected for Taiwan OTEC plants (Liao et al., 1986).
FIG. 6-52. Layout for Taiwan 50-MWe OTEC power plant (Liao et al, 1986).
they will be joined end to end to form the cold-water pipe. Pipe deployment would
involve the sequence of operations depicted in Fig. 6-55.
Warm Water. Details of the warm-water and mixed effluent deployment are
not available.
6.4.9.4 Energy Transfer
The installation of the power plant on the beach allows the generated power to be
transferred directly to the onshore utility. Details of the power conversion and
control equipment are not available.
OCEAN THERMAL ENERGY CONVERSION 337
FIG. 6-53. Schematic design of Taiwan 50-MWe OTEC power plant (Liao et al., 1986).
FIG. 6-54. Design of CWP joints for Taiwan 50-MWe OTEC power plant (Liao et al., 1986).
338 OTEC CLOSED-CYCLE ENGINEERING STATUS
FIG. 6-55. Deployment sequence for Taiwan 50-MWe OTEC CWP (Liao et al., 1986).
Table 6-14. Design features of the Taiwan Power Co. 50-MWe OTEC plants
Feature At Ho-Ping At Chang-Huan
Closed Rankine cycle; NH3 working fluid; shell-and-tube HX; titanium tubes; containment
system L 1 70 m, IV 77 m, H 40 m, depth below SL 1 5 m
Average T(C) 20.35 21.72
Power plant summary Evap. Cond. Evap. Cond.
HX internal shell diam. (m) 14 12 14 12.25
Tube OD (mm) 25.4 25.4 25.4 25.4
Effective tube length (m) 14 14 14 14
No. of tubes 79,954 62,860 79,954 79,604
Water flow (kg/s) 51,000 32,780 51,000 42,140
Reno. (H2O) 42,291 20,312 42,291 20,312
Prno. (H20) 6.437 11.512 6.437 11.512
Water vel. in tubes (m/s) 1.85 1.5 1.85 1.5
H20 inlet/outlet temp. (C) 24.35/21.49 4.0/8.3 25.95/23.07 4.0/8.3
Water pressure drop (m) 2.45 1.93 2.45 1.93
NH, flow (kg/s) 543 494 733 667
NH, temp. (C) 20.0 10.0 20.0 10.0
Operating pressure (kPa) 858 615 858 615
LMTD( C) 2.74 3.41 3.77 3.41
U 0 (W/m 2 C) 2,959 3,092 2,945 3,092
h 2
M ,(W/m C) 6,992 4,571 6,913 4,571
h"fouling (W/m2 C) 16,667 16,667 16,667 16,667
h wall (W/m2 C) 10,652 10,506 10,652 10,506
h NH, (W/m2 C) 24,365 28,501 24,365 28,501
In 1977, The Applied Physics Laboratory of The Johns Hopkins University (JHU/
APL) was tasked by DOE to prepare baseline preliminary engineering designs of
moored and grazing 40-MWe (net) OTEC plants that would furnish basic data on
systems requirements, performance, and costs. The information was required to
provide informed specifications for projected DOE industrial contracts for OTEC
plant construction. The baseline designs resulting from this task incorporate the
results of a number of earlier experimental and analytical studies of OTEC systems
requirements, including the conceptual design of a 100-MWe plant, design and tests
of a folded-tube heat exchanger module, design and test at 1/3 scale of a jointed
section of a 9.1 -m-diameter segmented CWP that would use lightweight concrete,
at-sea tests of a 1/6-scale jointed CWP which validated theoretical predictions of
CWP dynamics, tests of ultrasonic and mechanical systems for removal of biofoul-
ing from the heat exchanger tubes, and analyses of OTEC commercialization
potential (George and Richards, 1980).
The JHU/APL 40-MWe baseline designs update and augment a 1978 APL
design of a 10- to 20-MWe pilot plantship, sponsored jointly by DOE and the U.S.
Maritime Administration (MARAD) (George et al., 1979). The earlier design used
systems engineering to achieve minimal cost of a total OTEC system. Features of
340 OTEC CLOSED-CYCLE ENGINEERING STATUS
the design directed to this goal included a concrete barge-type hull, a segmented
CWP of lightweight concrete, an aluminum folded-tube HX, and plantship siting
for grazing on the tropical oceans near the equator to maximize power output.
In the subsequent development of the 40-MWe baseline, DOE asked APL to
expand the design to include the following:
1. Power increase to 40 MWe (nominal).
2. Provision of a 20-MWe power module based on the Lockheed power plant
design and a 20-MWe module of the APL design.
3. Alternative plant designs to include a moored configuration supplying electric
power to the island of Puerto Rico via underwater power cable, and a grazing
plantship to produce and store 125 mt/d of ammonia for bimonthly shipment
in ammonia tankers to onshore markets.
4. Performance and design improvements indicated by results of other OTEC
research and development programs.
The baseline design program involved a team effort headed by APL in which
the following organizations participated:
JHU/APL: Overall program direction. JHU/APL HX design, test, and analysis.
Overall systems engineering and cost evaluations.
ABAM Engineers, Inc.: Structural analysis, design, and cost estimates for the hull
and CWP. Development of the segmented CWP concept. Coordination of all
platform design activities.
L. R. Glosten & Associates: Naval architecture and marine engineering. Seakeeping
and stability analysis. Space layouts, outfitting, platform support systems.
Tokola Offshore, Inc.: CWP deployment and attachment. Construction and deploy-
ment scenarios for platform, CWP, discharge pipes, including costs. Selection
of platform heavy lift systems.
Seward Associates: Electrical engineering design of OTEC power system, includ-
ing ship services and substation for power transmission to shore.
J. R. Paulling, Inc.: Analysis of CWP and discharge pipes dynamics, including
development of computer codes and comparison of theoretical performance
with results of at-sea tests.
Trane Co.: Manufacturing study of folded-tube HX construction and costs, includ-
ing projections for large-scale production.
The following organizations contributed data, expertise, and constructive and
critical reviews of all aspects of the baseline designs:
NOAA
Argonne National Laboratory
TRW
SA1, Inc.
BARDI
M. Rosenblatt & Sons
LMSC
Simplex Wire and Cable
OCEAN THERMAL ENERGY CONVERSION 341
FIG. 6-56. Sketch of JHU/APL 40-MWe baseline OTEC ammonia plantship (George and Richards,
1980).
342 OTEC CLOSED-CYCLE ENGINEERING STATUS
FIG. 6-57. Subsystems layout of baseline 40-MWe OTEC barge (George and Richards, 1980).
Analysis of the maximum loads that would be imposed by the 100-year storm
defined the structural design and the post-tensioning and reinforcing steel require-
ments to maintain the structure in compression under the most extreme predicted
loads, with a safety margin of 100% (Mast, 1975; George and Richards, 1980). The
hull openings for the heat exchangers and CWP require that longitudinal bending
strength be provided by wing wall girders that extend the full length of the platform.
The analysis included consideration of the survival requirements for grazing
plantships stationed in the equatorial Atlantic Ocean [significant wave height (H
8 m, period (T0) 18.0 s] and for moored plants stationed near Puerto Rico (Hs 10.9
m, TQ 13.1 s) or near the island of Oahu in Hawaii (Hs 8.4 m, T0 11.7 s).
6.5.1.2 Power Systems
Details of the baseline 40-MWE OTEC HX design are provided in
Section 4.5. The OTEC barge design accommodates alternative 20-MWe power
system modules, of configurations proposed by Lockheed and JHU/APL, as shown
in Fig. 6.57. The dimensions and weight of the two systems are nearly the same.
Thus, the hull configuration is suitable for 40-MWe (net) power systems of either
design. Other compact power systems using the Trane or Alfa-Laval HX designs
could also be installed without major changes in the hull dimensions.
APL Power System. The APL power system was designed with two major
objectives:
1. Minimize HX cost by using low-cost, roll-welded aluminum tubing in a
compact folded-tube configuration with internal ammonia flow. This elimi-
OCEAN THERMAL ENERGY CONVERSION 343
FIG. 6-58. Schematic of Lockheed 5-MWe HX design for the 40-MWe OTEC baseline barge (George
and Richards, 1980).
344 OTEC CLOSED-CYCLE ENGINEERING STATUS
tion plant. In consultation with DOE, the design proposed by Lockheed for a power
module employing flat plate heat exchangers of the Alfa-Laval type was selected
as the second power module. A schematic view of the Lockheed HX configuration
is shown in Fig. 6-58 (Lockheed, 1978).
A study showed that the platform space and HX bays allotted to the APL
design were well suited to packaging the Lockheed module; thus no modifications
of the baseline hull were indicated. The plate heat exchangers are mounted in two
tiers in a heat exchanger bay. Seawater from the overhead pond enters the heat
exchangers at the sides, flows horizontally across the heat exchanger plates, and
then exits at the bottom of the HX bay. Liquid ammonia enters the evaporator from
below and flows vertically upward as it vaporizes. Vapor leaving the turbines enters
the condensers at the top and flows vertically downward to the sump from which
it is pumped to the evaporators. Analysis by Lockheed showed that this cross-flow
arrangement was superior to one using parallel flow.
6.5.1.3 Water Ducting Systems
Cold Water. Cold water is supplied to the OTEC power systems through a
9.1-m-diameter, 930-m-long, segmented concrete pipe (Cichanski and Mast,
1979). The pipe is supported by a ball-and-socket structure incorporated in the hull
at approximately the center of gravity. The joint allows the pipe to pivot freely
through an angle of 18 degrees to the vertical. It also allows the pipe to rotate about
the vertical axis (see Fig. 4-75) .The dynamics of the coupled system have been
analyzed in depth by Faulting (1980) and others, as discussed in Section 4.2 and in
George and Richards (1980). The analyses show that the coupled pipe-hull system
will survive the most extreme conditions of the 100-year storm for grazing
operation at the Atlantic-1 site, with a good safety margin, and for moored operation
at the Hawaii site. The analysis predicts that the design is marginal for the extreme
hurricane condition at the Puerto Rico site, where the combination of extreme
values of surface currents and waves leads to a predicted maximum pipe angle of
19.7 degrees (sum of extreme values due to hull deflections and surface currents).
The calculation does not include mitigating effects of mooring forces on the
platform motions or potential benefits of bow fairing of the rectangular platform.
Further study is required to indicate detail changes in design that might be required
for moored operation at this site. The cost of manufacture, assembly, and deploy-
ment of CWPs of this type was estimated in combined studies by ABAM, Concrete
Technology, Inc., Glosten Associates, and Tokola Offshore, Inc. The CWP manu-
facturing cost was independently verified by a professional estimating concern.
Warm Water. Warm water enters the evaporators through screens mounted at
the sides of the hull at a mean depth of 16. 6 m. The screen area is about 125 m2 for
each 10-MWe evaporator module.
Mixed Effluent. In the grazing mode of operation, the warm- and cold-water
effluents from the heat exchangers are discharged at the bottom of the platform,
where their higher density than the surrounding water causes them to sink. Since the
grazing platform is always moving into fresh water, there is no recirculation of the
discharged water into the warm-water inlets. The moored baseline plant is designed
OCEAN THERMAL ENERGY CONVERSION 345
with discharge pipes to carry the effluent to a depth below the thermocline, to
prevent reingestion and possible impacts on the near-shore environment. Eight
pipes 4.6 m in diameter and 76 m long are used to carry the mixed effluent below
the thermocline, where it is discharged and allowed to sink. A detailed structural
analysis of these pipes was not funded but will be necessary if they are to be retained
in the design. The OTEC-1 experiment indicated that these pipes may be unneces-
sary because the mixed plume descends rapidly and may not pose any reingestion
problem; however, termination of the program did not permit a conclusion to be
reached.
6.5.1.4 Energy Transfer Systems
The OTEC on-board electric power generation and distribution system is based on
the use of standard commercial equipment for primary and secondary applications
and is designed to comply with the requirements of IEEE standard No. 45 and
relevant regulations of the U.S. Coast Guard, ABS, NEMA, NFPA, and UL. There
are four 16-MWe (gross) ammonia turbine generators, each having its own set of
auxiliaries and switch gear. Ammonia storage, liquid nitrogen, circulating cooling
water, and generator loading systems are used in common. All of the generators may
be used in parallel, and in normal operation all power would be derived from them.
During start up or when the OTEC plant is shut down during storms, reserve power
is provided by diesel-generator sets. Tie feeders between the OTEC generators and
the reserve power units allow this interchange. The on-board power utilization
systems differ for the grazing and moored OTEC options; however, the systems are
the same up to the final phase. Figure 6-59 presents a line diagram of the basic
system. In the grazing plant, step-down/DC rectifiers are installed to furnish DC
current to the electrolyzer cells. In the moored plant, transformers step up the
voltage to 115 kV for cable transmission to shore.
Grazing Configuration. In the OTEC plantship, electric power generated on-
board is used to produce a chemical product that stores the energy for later transport
to shore. Water electrolysis provides an efficient method for converting electrical
energy to chemical energy and is the basic step in making all of the surface waters
of the tropical oceans a source of energy that can be transported to land sites.
In the baseline 40-MWe (net) OTEC plantship the power produced by the
turbo-generator is used to produce ammonia (NH3). The on-board ammonia plant
includes water electrolyzers to generate gaseous hydrogen (along with gaseous
oxygen that is vented to the air), an air separation plant to produce pure nitrogen,
a catalytic converter to combine the hydrogen and nitrogen to form ammonia,
ammonia liquefaction and storage equipment, and facilities for transferring the
liquid ammonia to tankers for shipment to world ports. Details of the ammonia
synthesis process are described in Section 4.3.
Commercial ammonia plants typically are sized to produce 1000 tons/d (909
mt/d) of liquid ammonia. The output of the 40-MWe (net) baseline plantship would
be one-eighth of this amount.
The feasibility and practicality of installing an ammonia plant on an OTEC
platform were investigated in detail in the baseline study, including possible effects
346 OTEC CLOSED-CYCLE ENGINEERING STATUS
FIG. 6-59. Proposed wiring diagram for the 40-MWe grazing and moored OTEC systems (George
and Richards, 1980).
of ship motions on the process operations, with favorable results. Smaller, less
efficient, process components would be required for the baseline vessel in compari-
son with commercial plants; however, all of the equipment apart from the electroly-
sis system is commercially available. The process design would be similar to the
commercial ammonia plant designs except for the simplification resulting from
replacement by water electrolysis of the expensive steam-reforming process for
hydrogen production. A flow diagram of the process is shown in Fig. 6-60. An
installation diagram of a 113-ton/d ammonia plant on the OTEC platform is shown
in Fig. 6-61.
Moored Configuration. It was recognized early in the OTEC program that
at favorable sites moored OTEC plants could deliver OTEC power directly to
onshore facilities via underwater power cables (Winer, 1977). The requirements for
this mode of OTEC operation were also determined in the 40-MWe (net) baseline
design study. The site selected for detailed study was near Punte Tuna, Puerto Rico.
Power transfer requires on-board equipment to convert the OTEC bus bar
output to suitable voltage and frequency for transmission through the selected
power cable and equipment to support the power cable that must connect to the
OCEAN THERMAL ENERGY CONVERSION 347
FIG. 6-60. Flow diagram for OTEC ammonia plant (George and Richards, 1980).
OTEC platform through a flexible junction. A proposed arrangement for the aft
cable installation on the platform is shown in Fig. 6-62. Experiments with power
cables under simulated OTEC conditions indicated satisfactory durability could be
achieved (Morello, 1981; Pieroni et al., 1979; Pieroni, 1980; Soden et al., 1981,
1982); however, a complete design of the power cable system had not been
completed when the program was terminated. A diagram of the electrical system,
which satisfies the total requirements of both moored and grazing OTEC plants, is
shown in Fig. 6-59.
The principal features of the APL 40-MWe (nom) OTEC baseline plants are
listed in Table 6-15.
FIG. 6-61. Schematic diagram of 40-MWe OTEC ammonia plant installation (George and Richards,
1980).
The goal of the OTC contract was to develop, with government cost sharing,
an engineering and economic evaluation of an OTEC power plant design that would
provide a firm basis for detailed engineering and construction of a 40-MWe shore-
based OTEC demonstration plant. In the conduct of the contract, the following
topics were evaluated in some depth:
System performance and operational requirements
Government regulations and operational requirements
OTC performance and operational requirements
Codes, standards, and recommended practices
HECO requirements
Possible impact on military operations near Ohau
Aesthetic considerations
Site-specific design conditions
Site description
OCEAN THERMAL ENERGY CONVERSION 349
FIG. 6-62. Schematic diagram of power cable equipment installation on 40-MWe moored OTEC plant
(George and Richards, 1980).
Table 6-15. JHU/APL preliminary design of baseline 40-MWe (nom) OTEC plants
Hull
Rectangular barge
Dimensions m (ft): L 135 (443.5), W 42.1 (140), D 31.4 (103)
Hull material: post-tensioned concrete
Power plant
Closed Rankine cycle; ammonia working fluid
Folded tube HXs of JHU/APL design with nested 0.072-m (3-in.) tubes,
or plate HXs of Lockheed design using titanium plates
Internal ammonia flow; 4 10-MWe (net) modules
Nominal operating characteristics
Nominal A7"(C)
Annual average 23.65
Seasonal ATtC) (ATL-1): Feb 23.6, May 24.6, Aug 23.4, Nov 23.0
FIG. 6-63. Artist's sketch of the OTC 50-MWe OTEC power plant at Kca-holc Point, Hawaii (OTC,
1984).
352 OTEC CLOSED-CYCLE ENGINEERING STATUS
water platform layout. A sketch of the subsystems layout is shown in Fig. 6-64. A
schematic of the underwater structure of the OTC plant is shown in Fig. 6-65. The
generated power is carried to the HECO plant via power cables mounted on the
trestle shown in Fig. 6-63 that provides access to the LBCS from the shore.
6.5.2.2 Water Ducting
Design of the CWP system required an extensive study of the physical and
hydrological features of the Kahe Point site. The studies included detailed bathymetric
surveys with a resolution of 50 m covering approximately 5.5 km2 bordering Kahe
Point. Bottom core samples and subsurface data representative of the area were also
acquired. With this information it was possible to define the pipe structural
requirements and to lay out a pipe trajectory that would minimize risks in
deployment and long-term operation and would be the most cost effective. The
bathymetry and topography of the surveyed area are shown in Fig. 6-66.
In the final preliminary design of the CWP, water enters the LBCS through a
bottom-mounted pipe 3660 m long that draws water from an offshore depth of 670
m (2200 ft). The CWP is divided into two major segments. The seaward section of
the pipe is of FRP. It is 2560 m long (8400 ft), of 6 m diameter (19.8 ft), and 0.072
m wall thickness (2.83 in.). It is composed of segments 75-90 m long, joined by
flexible bellows, and supported on a steel support structure that rests on the bottom.
This structure protects the pipe from bottom erosion, relieves tension loads on the
FIG. 6-64. Layout of subsystems for the OTC 50-MWe OTHC power plant (OTC, 1984).
OCEAN THERMAL ENERGY CONVERSION 353
FIG. 6-65. Sketch of the underwater structure of the OTC 50-MWe OTEC power plant (OTC, 1984).
FRP, provides weight to ensure stability against hydrodynamic loads, and allows
flexibility to accommodate seismic loads, bottom scour, and differential settling.
This CWP section extends 2560 m (8400 ft) from the deep-water inlet to the top of
the escarpment at a depth of 82 m (270 ft). A profile of the FRP pipe and a schematic
of the ducting construction and support structure are shown in Fig. 6-67.
At the top of the escarpment, the FRP pipe connects to a triple-pipe concrete
structure that combines a pipe to conduct the cold water to the LBCS with two
parallel pipes that carry the mixed effluent (flowing in the opposite direction) from
the OTEC plant to the discharge point. A profile of this section and a cross section
of the concrete triple-pipe structure are shown in Fig. 6-67.
Warm near-surface water enters the LBCS through a structure on the landward
side, where it is mixed with warm water conducted from the HECO condenser
discharge. After passing through the OTEC power system, the exhaust streams
from the evaporators and condensers are mixed and then conducted through the
bottom-mounted concrete ducting structure to the edge of the escarpment, where
the combined flow is discharged at a depth of approximately 115 m (380 ft).
6.5.2.3 Support Facilities
All support facilities not directly involved in plant power production are sited
onshore. These include offices, laboratories, maintenance facilities, ammonia and
equipment storage, and related equipment.
354 OTEC CLOSED-CYCLE ENGINEERING STATUS
FIG. 6-66. Topography of the offshore area of the OTC 50-MWe OTEC power plant (OTC, 1986).
FIG. 6-67. Water ducting arrangement for the 50-MWe OTC OTEC power plant (OTC, 1984).
OCEAN THERMAL ENERGY CONVERSION 355
The principal features of the OTC design are listed in Table 6-16. Cost
information is listed in Chapter 7.
Evaporator Condenser
Heat load (MWt) 1 ,765 1,711
Water flow (kg/s) 13,747 11,510
Ammonia flow (kg/s) 1,434 1,434
Number of HX tubes 40, 1 28 37,67 1
Tube length (m) 13.65 15.03
HXarea(m 2 ) 321,024 301,368
Waterside 243,197 251,239
Ammonia side 262,442 271,121
Overall heat trans, coeff. (W/m2 K) 2,516 2,601
Fouling coeff. (m2 K/W) X 105 1.76 1.76
Water inlet (outlet) temp, f C) 26.8 (22.8) 5.0 (9.7)
Ammonia inlet (outlet) temp. (C) (21.44) 10.66
Log mean temp. diff. (LMTD) (+C) 2.95 2.69
Seawater p (m) 2.39 2.25
Sum of inlet & outlet p 0.60 2.91
Heat exchanger p 2.25 2.39
Seawater velocity (m/s) 1.37 1.22
CWP flow (m-Vfs MWe (net)]) 2.25
Net power/total HX area (kWe/m2) 0.08 1
6.6 CONCLUSIONS
The review in this chapter of the OTEC programs conducted in the United States
and abroad shows that the technology required for high-confidence pilot plant
demonstration of sea-based and land-based OTEC systems is now available.
Satisfactory solutions have been demonstrated at reasonable scale for all of the
technical problems that were identified as major barriers to OTEC commercial
operation in early reviews of OTEC:
356 OTEC CLOSED-CYCLE ENGINEERING STATUS
REFERENCES
Anderson, A. R., 1977. "World's largest prestressed LPG vessel." /. Prestressed Concrete
Institute, 22, 1.
Anderson, J. H., 1985. "Ocean thermal power-the coming energy revolution." Solar & Wind
Technology, 2, 25.
, 1986. Sea solar power. Sea Solar Power Inc., Oct.
and J. H. Anderson, Jr., 1977. "Compact heat exchangers for sea thermal power plants."
Proc. 4th Annual Conf. on Ocean Thermal Energy Conversion, New Orleans, La.,
March, 6, 3.
Ashworth, D. J., and G. Slebodnick, 1980. "Cost and configuration of a closed cycle OTEC
power system using brazed aluminum plate and fin heat exchangers." Proc. 7th Ocean
Energy Conf., Washington, D.C., June, II, 7.1.
Avery, W. H., D. Richards, and G. L. Dugger, 1985. "Hydrogen generation by OTEC
electrolysis, and economical energy transfer to world markets via ammonia and
methanol.'V. Hydrogen Energy, 10, 727.
, D. R. Richards, W. G. Niemeyer, and J. D. Shoemaker, 1983. "OTEC energy via
methanol production." Proc. 18th Intersociety Energy Conversion Engineering Conf.,
Orlando, Fla., August, 1, 346.
Babbitt, J. F., 1981. Closed cycle ocean thermal energy conversion pilot plant-grazing
ammonia plantship. SOLARAMCO, Tulsa, Okla.
BARDI, 1982. Coal-to-methanol study using OTEC technology. For Johns Hopkins Univer-
sity Applied Physics Laboratory. Brown and Root Development, Inc., Houston, Tex.
Barsness, E. J., et al., 1978. Conceptual design of an OTEC power system using modular heat
exchangers. Westinghouse, March.
Baumeister, T., E. A. Avallone, andT. Baumeisterlll, 1978. Marks' standard handbook/or
mechanical engineers. 8th Ed. New York: McGraw-Hill.
Castellano, C. C., 1981. "Overall OTEC-1 status and accomplishments." Proc. 8th Ocean
Energy Conf., Washington, D.C., June, 2, 971.
, E. A. Midboe, and G. M. Hagerman, 1983. "The U.S. Department of Energy's 40 MWe
ocean thermal energy conversion pilot plant program: A status report." Proc. Oceans
'83 2, 728.
Cichanski, W. .1., and R. F. Mast, 1979. " Design of a concrete cold water pipe for ocean
thermal energy (OTEC) systems." 11th Annual Offshore Technology Conf., Houston,
Tex., 1653.
OCEAN THERMAL ENERGY CONVERSION 357
Denton, J. W., P. Bakstad, and K. Mcllroy, 1979. "Test article and a 10-MWe power
module." Proc. 6th OTEC Conf. Washington, D. C., June, 1, 8.3-1.
Dugger, G. L., J. E. Snyder, andF. Naef, 1983. "Ocean thermal energy conversion: Historical
highlights, status, and forecast." /. Energy 7, 293.
EBASCO, 1984. Final report. Coal-to-methanol OTECplantship study using the Rockwell
molten carbonate gasification system. EBASCO Services Corp., Los Angeles, Cal.
Foust, H. D., 1979. U. S. Patent No. 4,276,927 for plate type heat exchanger. U. S. Patent
Office, June.
, 1981. "Constructability of extended surface heat exchangers for OTEC." Proc. 8th
Ocean Energy Conf., Washington, D. C., June, 2, 717.
General Electric, 1983. Closed cycle OTEC power plant final report. General Electric Co.,
Schenectady, N. Y.
George, J. P., 1979. "System design considerations for a floating OTEC modular experiment
platform." Proc. 6th OTEC Conf., Washington, D. C., June, 5.5-1.
, and D. Richards, 1980. Baseline designs of moo red and grazing 40-MWe OTEC pilot
plants. Johns Hopkins Univ. Applied Physics Lab., June, SR-80A&B.
, D. Richards, and L. L. Perini, 1979. A baseline design of an OTEC plantship. Johns
Hopkins Univ. Applied Physics Lab., SR-78-3A.
Geothermie Actualites, 1985. L'Energie thermique des rners. Geothermie Actualites.
Gershunov, E. ML, Y. H. Ozudogru, and J. M. Betts, 1981. "Analysis of the up-ending
problem of the OTEC-1 cold water pipe. "Proc. 8th Ocean Energy Conf., Washington,
D. C., June, 2, 9-1.
Global Marine Development, Inc., 1981. Floating vessels for industrial plants. U. S.
Department of Commerce.
Griffin, A. B., and M. P. Bianchi, 1979. "Cold water pipe preliminary design studies."
Technical Workshop on Ocean Thermal Energy Conversion, Washington, D. C., Jan.
Griffin, A. B., and L. R. Mortaloni, 1980. "Baseline designs for three OTEC cold water
pipes." Proc. 7th Ocean Energy Conf., Washington, D. C., June, 1, 3.2.
Hoffman, B., and E. C. Paoloni, 1984. "Commercialization of OTEC: A 40-MWe OTEC
power plant for Hawaii." Oceans '84. Washington, D. C., Sept.
Homma, T., and H. Kamogawa, 1979. "An overview of Japanese OTEC development."
Proc. 6th OTEC Conf., Washington, D. C., 1, 3.31.
IFREMER, 1985. Ocean thermal energy conversion, the French program, a pilot electric
power plant for French Polynesia. IFREMER, March.
International Maritime Associates, 1981. The development of waterborne alcohol fuel
plants. U. S. Dept. of Commerce, 1, 3.
Ito, F., and Y. Seya, 1985. Operation experience of the 100-kW OTEC and its subsequent
research." Japanese-French Symp. on Ocean Development, Tokyo, Sept.
Jones, M., V. Thiagarahan, and K. Sathjanarayna, 1981. "OTEC aluminum integration
studies." Proc. 8th Ocean Energy Conf., Washington, D. C., 1, 643.
Kamogawa, H., 1972. "Equatorial marine-industrial complex. A report for National Re-
sources Development Committee of the Pacific Basin Economic Council at the 5th
general meeting in New Zealand." Proc. Second International Ocean Development
Conf. Tokyo, October, 1.
, 1980. OTEC research in Japan. Pergamon Press Ltd., London, 5, 481.
Kawano, S., T. Takahata, and M. Miyoshi, 1983. "Performance tests of a condenser for a 100-
kW (gross) OTEC plant." Proc. ASME-JSME Thermal Eng. Joint Conf., Honolulu,
March, 2, 247.
358 OTEC CLOSED-CYCLE ENGINEERING STATUS
Kohl, A. L., M. H. Slater, and P. R. Hsia, 1980. "Operation of the molten salt coal gasification
process." 7th Energy Technology Conf. and Exposition, Washington, D. C., March, 1.
Larsen-Basse,J., 1983. "Effect of biofouling and countermeasures on heat transfer in surface
and deep ocean Hawaiian waters-early results." ASME-JSME Thermal Eng. Joint Conf.
Proc., Honolulu, 2, 285.
Leitner, M. I., 1979. "Design of a 10-MWe power system and heat exchanger test articles
using plate heat exchangers." Proc. 6th OTEC Conf., Washington, D. C., 1, 8.4-1.
Liao, T., J. G. Giannotti, and P. R. Mater, 1986. Feasibility and concept design studies for
OTEC plants along the east coast of Taiwan, Republic of China. Taiwan Power Co.,
April.
Lloyd's Maritime Directory, 1988. Lloyd's of London Press.
Lockheed, 1978. OTEC platform and configuration study. Lockheed Missiles and Space Co.
Inc., 4 volumes.
, 1979a. Preliminary design report for OTEC station-keeping (SKSS). Lockheed
Missiles and Space Co. Inc.
, 1979b. PSD-I1final design briefing. Lockheed Missiles and Space Co. Inc., June, Task 2.
Lorenz, J. J., D. Yung, P. A. Howard, C. B. Panchal, and F. W. Poucher, 1981a. OTEC-1
power system test program: performance of one-megawatt exchangers. Argonne
National Lab., OTEC-PS-10.
Lorenz, J. J., D. Yung, P. A. Howard, C. B. Panchal, and F. W. Poucher, 1981b. "Heat
exchanger test results." Proc. 8th Ocean Energy Conf., Washington, D. C., June, 2,977.
MARAD, 1980. The development of waterborne alcohol fuel plants. U. S. Dept. of
Commerce (three vol.).
Marchand, P., 1985. "French thermal energy conversion program." Proc. French-Japanese
Symp. on Ocean Development, Tokyo, Sept., 1.
Mast, R. F., 1975. "The ARCO LPG vessel." Conf. on Concrete Floating Ships and Terminal
Vessels, 1.
Mitsui, T., F. Ito, Y. Seya, and Y. Nakamoto, 1983. "Outline of the 100-kW OTEC pilot plant
in the Republic of Nauru." IEEE/PES 1983 Winter Meeting, New York, Jan., 212.
Mochida, Y., T. Takahata, and M. Miyoshi, 1983. "Performance tests of an evaporator for
a 100-kW (gross) OTEC plant." Proc. ASME-JSME Thermal Eng. Joint Conf.,
Honolulu, March, 2, 241.
Morello, A., 1981. "Constructability of submarine bottom cables for OTEC power transmis-
sion." Proc. 8th Ocean Energy Conf., Washington, D. C., June, 2, 747.
Motor Ship Press, 1988. Directory of shipowners, shipbuilders, and marine engineers.
Ocean Thermal Corporation, 1984. Deployment of the land-based containment system for the
40 megawatt Ocean Thermal Corporation OTEC plant. Makai Ocean Engineering, Inc.
O'Connor, J. S., 1981. Light weight concrete cold water pipe tests: Phase II. Johns Hopkins
University Applied Physics Lab., SR-80-5A.
, 1980. "The development of a lightweight concrete for ocean thermal energy conver-
sion (OTEC) systems." International Conf. on Performance of Concrete Marine
Environment, August.
Olmsted, M. G., M. J. Mann, and C. S. Yang, 1979. "Optimizing plant design for minimum
cost per kilowatt with Refrigerant-22 working fluid." Ocean Thermal Energy for the
80's, I, 8.51.
Owens, W. L., and L. C. Trimble, 1980. "Mini-OTHC operational results." Proc. 7th Ocean
Energy Conf., Washington, D. C., June, 2, 14.1-1.
Paoloni, E. C., 1984. "Optional strategy for financing a 40-MWe OTEC power plant." Proc.
Pacific Congress on Marine Technology (PACON84), MRM 8/7.
OCEAN THERMAL ENERGY CONVERSION 359
Paulling, J. R., 1980. Theory and users manual for OTEC cold water pipe programs,
ROTECF and SEGPIP. J. R. Paulling Assoc., Berkeley, Cal.
Pieroni, C. A., 1980. "Material evaluation and testing program for OTEC riser cable." Proc.
15th Intersociety Energy Conversion Engineering Conf., Seattle, Wash., 1, 360.
, R. T. Traut, and D. O. Libby, 1979. "The development of riser cable systems for OTEC
plants." Proc. 6th OTEC Conf., Washington, D. C., June, I, 7.2-1.
Richards, D., W. H. Avery, E. J. Francis, M. Jones, B. Heyer, A. L. Kohl, and J. K. Rosemary,
1984. OTEC methanol from coal piantship studies. American Society of Mechanical
Engineers, New York, N. Y., 84-WA/SOL-32.
Sanchez, J. A., 1980. OTEC alternative for Puerto Rico vs. coal-oil-nuclear. Phase II. Clean
Energy Research Institute, Miami, Fla., Dec., 415.
Science Applications, Inc., 1979. Design of a 1/3 scale fiberglass OTEC cold water pipe.
Science Applications, Inc.
Snyder, J. E., 1978. "1-MWe heat exchanger for OTEC. Status report." Proc. 5th Ocean
Thermal Energy Conversion Conf., Miami Beach, Fla., VI, 20.
, 1980. 1-MWe heat exchangers for OTEC. Final report. TRW Systems Group.
Soden, J. E., R. Eaton, and J. P. Walsh, 1982. "Progress in the development and testing of
OTEC riser cables." Oceans 82 Conf. Records (Marine Technology Society), Washing-
ton, D. C., Sept., E, 587.
, D. O. Libby, and J. R. Spiller, 1981. "A study of ocean cable ships applied to submarine
power cable installation." Proc. 8th Ocean Energy Conf., Washington, D. C., June, 2,
617.
Svenson,N. A., 1979. "Overview of the OTEC-1 design."Proc. 6thOTECConf., Washing-
ton, D. C., 1, 5.3.
Trimble, L. C., and W.L. Owens, 1980. "Review of Mini-OTEC performance," 15th
Intersociety Energy Conversion Conf. Seattle, Wash., Aug., I, 1331.
, and R. L. Potash, 1979. "OTEC goes to sea. A review of Mini-OTEC." Proc. 6th OTEC
Conf., Washington, D. C., June, I, 5.2-1.
TRW, 1979. Ocean thermal energy conversion cold water pipe preliminary design final
report. TRW Energy Systems Group.
Uehara, H., 1982. "Research and development on ocean thermal energy conversion in
Japan." Proc. 17th IECEC Conf., 3, 1454.
, H. Kusuda, M. Monda, T. Nakaoka, and H. Sumitomo, 1983. "Shell-and-plate type
heat exchangers for an OTEC plant." Proc. ASME-JSME Thermal Eng. Joint Conf.,
Honolulu, Mar., 2, 253.
, S. Nagasaki, and H. Yokohama, 1980. "Deployment of cold water pipe in the Japan
Sea." Proc. 7th Ocean Energy Conf., Washington, D. C., June, 1, 14.4.
, K. Masutani, and M. Miyoshi, 1978. "Heat transfer coefficients of condensation on
vertical fluted tubes." Proc. 5th Ocean Thermal Energy Conversion Conf., Miami
Beach, Fla., Feb., VI, 261.
, and H. Kusuda, 1978. "Plate type evaporator and condenser for ocean thermal energy
conversion plant." Proc. 5th Ocean Thermal Energy Conversion Conf., Miami Beach,
Fla., Feb., VI, 261.
Vincent, S. P., and C.H. Kostors, 1979. "Performance optimization of an OTEC turbine."
Proc. 6th OTEC Conf., Washington, D. C., I, 8.7-1.
Winer, B., 1977. "Electrical energy transmission for OTEC power plants." Proc. 4th Annual
Conf. on Ocean Thermal Energy Conversion, New Orleans, La., March.
Yaffo, J. E., A. F. Butler, and A. B. Griffin, 1982. "OTEC power for Hawaii." Marine
Technology Workshop, Washington, D. C., 14.
7
OTEC CLOSED-CYCLE SYSTEMS COST EVALUATION
firm quotes. The fraction of the total cost in this category ranges from 45% of the
total for the ammonia plantship to 70% for the methanol plantship. Moderate
uncertainty of 20-35% is assigned to components or construction technologies
that are commercially available at smaller scale or under different working
conditions but must be modified for OTEC use. The corresponding fractions of the
total cost in this category are 41 % and 23% for the two cases. High cost uncertainty
of 35 to +100% is assigned to fabrication and deployment of the cold-water pipe.
The corresponding percentages of total cost are 13 % and 7%. The weighted average
risks of cost underestimates or overruns in constructing and deploying OTEC
systems are thus judged to be between 20% and 30%. Scaling factors and
experience factors1 are used in deriving the final estimates.
It should be noted that all complete OTEC installations will incorporate:
1. A platform system or land-based containment system to support and house the
OTEC subsystems, including water-pumping and distribution, platform
stationkeeping, and auxiliary platform services.
2. An OTEC power plant including heat exchangers, turbines, electric generators,
water and working-fluid pumps, and control equipment.
3. Water ducting equipment.
4. An energy transfer system. This may include a process plant and related
equipment for fuel production, storage, and transfer; equipment for routing
electric power to consumers, mariculture installations, fresh-water production,
and use of the cold-water effluent for air conditioning.
5. Support facilities and equipment, including shops, personnel accommoda-
tions, etc.
and by the requirement of a platform that will withstand the wave action in the near-
shore zone.
7.2.2.2 General Electric Conceptual Design of a Tower-Mounted OTEC Power
Plant for Hawaii
Costs estimated in the DOE supported conceptual design study, discussed in
Section 6.4, are listed in Table 7-5.
OTEC CLOSED-CYCLE COST EVALUATION 367
7.2.2.3 Puerto Rico Electric Power Co. Conceptual Design of a 40-MWe (Nom)
Tower-Mounted OTEC Plant
The costs quoted for the PREPA installation, described in Chapter 6, are presented
in Table 7-6.
7.2.2.4 French Designs of 5-MWe OTEC Land-Based Plant for Tahiti
French plans for a 5- to 10-MWe OTEC demonstration plant to be sited in Tahiti
were discussed in Chapter 6. Preliminary designs of a 5-MWe closed-cycle plant
and of an alternative 5-MWe open-cycle plant were completed, including equip-
ment for the production of fresh water in each system design. The cost assessment
led to essentially the same totals for the two options, as shown in Table 7-7
(Gauthier, 1986).
7.2.2.5 Taiwan 100-MWe (Gross) Land-Based OTEC Power Plant
Characteristics of land-based OTEC plants designed for sites on the island of
Taiwan were presented in Chapter 6. The estimated costs for a 74-MWe (net) plant
are listed in Table 7-8 (Liao et al., 1986).
Table 7-6. Estimated phase IV costs of PREPA 40-MWe (net) pilot plant ($M1982)
Tower system 21
Fabrication 13.9
Transportation 0.6
Installation 6.5
Power plant system 117.4
Heat exchangers 62.8
Seawater systems 12.9
Turbine-generator 10.0
Biocontrol 7.4
Ammonia systems 5.0
Startup/standby power 7.0
Control and elect. 10.6
Miscellaneous 1.5
Water ducting 22.2
CWP incl. deployment 18.6
Warm and mixed systems 3.6
Energy transfer system 66.0
Acceptance testing 2.0
Deployment services 20.0
Industrial facilities 2.0
Eng. and detail design 2.0
Total 259.4
$/kW 6485
sales price of the product is determined by the market. The profitability of the
investment is then the difference between the two values over the life of the plant.
Although the amortization costs will be known before construction begins, the
estimate of profitability must include a forecast of the course of inflation or
deflation of energy and fuel prices as a function of plant life. Fossil fuel prices are
expected to rise as U.S. reserves are depleted, but are subject to manipulation by the
Arab nations, who possess the largest share of the world's oil reserves. Thus, a
decision by private investors to proceed with OTEC involves an assessment of risk
that affects the rate of return needed to make the venture of interest. Government
cost sharing of construction of OTEC demonstration vessels in the 50- to 100-MWe
range, which was a provision of the 1980 public laws PL-310 and PL-320, and
government-supported loan guarantees such as the U.S. Maritime Administration
(MARAD) Title XI program or the Japanese Sunshine program may be essential for
large-scale OTEC commercialization.
Project financing in general requires two parties: (1) the project sponsors who
build and operate the OTEC plant, sell the product, and receive the profits, and (2)
lenders who provide the funds for construction and implementation and receive
interest on the money lent. The first group are "venture capitalists," the second
bankers and other financial institutions. Thus the total investment consists of equity
and debt. Loan guarantees available from MARAD for ship construction can be
arranged to cover 87.5% of the total investment, but 75-80% is more common. Such
loans substantially reduce the risk to the investor because loan approval, after in-
depth scrutiny by MARAD, carries a guarantee backed by the government. The
project will have a negative cash flow in the early years. For investors who have
profits in other operations, OTEC losses can be deducted from the total income,
thereby reducing the investor's total taxes, in effect providing income from the
operating losses via the tax benefit. Other sponsors will invest because, if profitable
operation is attained, the receipts from the product sales can lead to a large rate of
return on their investment. For example, a return of 10% on total investment
corresponds to a 50% rate of return on equity for an investor who has supplied 20%
370 OCEAN THERMAL ENERGY CONVERSION
of the plant investment from private funds and borrowed the remaining 80%. Thus,
the total financial package may take many forms depending on the ingenuity and
resources of the investors.
OTEC plants and plantships can be profitable if conditions can be created that
will enable commercial production to be established. The requirements are docu-
mented in the following sections of this chapter and in Chapter 8.
1. The project is valued as an all-equity financed firm. Cash flows for a selected
product sales price over the life of the project are identified for each period and
are then discounted using the standard formula to find a net present value
(NPV). The cash flows are established by entering data in a spreadsheet that
lists values over the life of the project for the terms calculated from the
following function:
a. List revenues from product sales;
b. Subtract operating expenses;
c. Subtract depreciation;
d. Equals earnings before taxes (EBT);
e. Subtract taxes on EBT;
f. Equals earnings after taxes (EAT);
g. Add-back depreciation;
h. Subtract additional working capital;
i. Subtract net capital expenditures;
j. Equals unlevered [sic] free cash flows.
2. The unlevered free cash flows are then discounted using a required rate of
return based on the expected rate of return offered to investors by equivalent-
OTEC CLOSED-CYCLE COST EVALUATION 371
risk investments traded in capital markets. This is the net present value (NPV)
of the investment.
3. Side effects of financing, primarily associated with tax shields provided by
interest payments on debt, are calculated.
4. The present value of the side effects is calculated, using the interest rate of the
debt as the discount rate, and then added to the net present value of the
unlevered free cash flows. This defines the adjusted present value (APV).
5. The decision rule is used that the APV must be greater than zero dollars. If the
APV is negative, the project will either provide a negative rate of return or a
positive rate of return that is inadequate to compensate investors for their
opportunity cost relative to other possible investments of equivalent risk.
The following assumptions were made in assessing the OTEC methanol base
case model:
1. Rate of return. For risk-free debt this is assumed to be equal to the yield
on 30-year U.S. Treasury notes, in 1989 around 8.00%.
2. Market premium. Six percent is assumed.
3. Project beta. This is a factor that is used to define the interest premium
on the borrowed capital relative to U.S. Treasury notes, that is paid by
investors in a particular industry. If Treasury notes pay 8%, the market
premium is 6%, and the value of beta is 0.83 for the OTEC project, then the
interest charge will be 8% + 6% x 0.83 = 12.98%. The beta value of 0.83
is based on 1988 equity betas of Dow Chemical, DuPont, Hercules,
Monsanto, Olin, Rohm and Haas, and Union Carbide. Beta is a measure of
the expected price stability of methanol or ammonia relative to the average
of all commodities listed in the consumer price index. A value less than 1.0
indicates more stability than the average.
4. Permanent financing interest rate. A value of 13% was chosen based on
the yield of high-interest-rate corporate bonds (BB/Ba-C) as of November
1988.
5. Construction financing. An interest rate of 12% was chosen, reflecting
1990 interest rates for short-term construction loans plus a premium to
allow for uncertainties in construction time.
6. Equity. A value of 20% was selected. Debt as percentage of total capital
was assumed to be 80% equal to the value of the debt for a methanol plant
of similar size completed in 1987 in Punta Arenas, Chile.
7. Methanol price. The amortized cost of methanol from a new U.S. plant
using natural gas at the market price in 1989 was estimated to be in the range
of $0.55-0.60 /gal. In 1990 the sales price of methanol was $0.70/gal.
8. Methanol production. The design methanol production rate per OTEC
plantship is 199 million gallons per year. The annual coal cost is 23.5
million dollars ($23.5M) (470,000 tons/year at $50/ton). Coal and methanol
shipping costs are $20/ton each. (These values are taken from A very et al.,
1985.)
372 OCEAN THERMAL ENERGY CONVERSION
9. Marginal tax rate. The 1989 top marginal tax rate for corporations was
34%. This value is used.
10. Depreciation schedule. This is based on the assumption that accelerated
depreciation will be available.
11. Inflation rate. The calculation is based on zero rate of inflation.
With the assumptions listed, a computer program was prepared following the
Mossman rationale. It relates the profitability of an OTEC venture to the values of
the plant investment, interest rates, operating and maintenance charges, and
methanol sales prices.
For the first-of-a-kind 200-MWe OTEC methanol plant, the nominal plant
investment, taken from Table 7-2, is estimated to be 960 million dollars ($960M,
in 1990S).2
The fixed cost estimate will be reduced and the financial prospects enhanced
by the following considerations:
1. The APL plant investment is based on costs of construction in U.S. shipyards.
Construction costs, including outfitting, of large ships in Japan in 1986 were
one-half those in U.S. shipyards and, in Korea, were only one-third (Bunch,
1987, 1988).
2. The sales price of methanol is assumed constant over the plant life; that is, there
is no allowance for inflation in the calculated revenues of $78.0M/year.
Operating and maintenance costs are also assumed to be constant at $50.9M/
year. Inflation acting on the difference would increase the calculated present
value of the net receipts.
3. U.S. Navy experience with large orders for destroyers of the same specifica-
tions showed that the delivered cost of the second vessel was 0.8 times that of
the first and an experience factor3 of 0.93 applied to the remaining orders of
20+ vessels. Applying these values of OTEC methanol plantships, the cost for
the 8th is 70% of the cost of the first, the cost is 60% for the 32nd, and so on
(Fink, 1987).
4. A government commitment to provide incentives for the production of low-
polluting vehicle fuels will lead to demands for large increases in methanol
production that will cause methanol prices to increase toward parity with
premium gasoline on a miles per gallon (mpg) basis.
The graph shown in Fig. 7-1 summarizes the results of the financial analysis.
The lines of the graph show the APV as a function of methanol sales price for
estimated plant investment values. The lines represent the following selection of
values for the estimated plant investment, starting from the bottom line:
1. Plant investment 30% above the nominal value of $960M, reflecting the upper
estimate of cost uncertainty for the first plant constructed in a U.S. shipyard at
1988 estimated costs.
2. Plant investment equals the nominal value.
3. Plant investment 20% below the nominal value, reflecting the lower estimate
of cost uncertainty for U.S. construction.
OTEC CLOSED-CYCLE COST EVALUATION 373
FIG. 7-1. Mossman profitability diagram for 200-MWe OTEC methanol fuel production.
gasoline. This would displace crude oil imports costing $14 billion/year at the 1990
price of $20/bbl. The economics are discussed in more detail in Chapter 9.
Methanol is also a favored fuel for use in fuel cells to generate electric power
(Patel, 1983; Patel et al., 1982), as an alternative to electric power generation from
fossil fuel or nuclear power plants. A discussion of the economics of this option is
presented in Section 8.3.
7.3.2 OTEC Ammonia Commercialization
Production of ammonia on OTEC plantships can supply world needs for a practical
motor vehicle fuel that produces only water and nitrogen as products of combustion.
Experimental work has demonstrated that ammonia can be a practical substitute for
gasoline, burning cleanly with high efficiency and a measured octane number of
111 (Avery, 1988). Use of OTEC ammonia instead of gasoline would eliminate
5 tons per year of CO2 added to the atmosphere by an average automobile, or
roughly 500 million tons per year for the total number of U.S. automobiles.
Ammonia is also an attractive fuel for fuel-cell production of electric power. This
option is discussed in Section 8.3.
Profitability projections for OTEC ammonia production have been made
using the Mossman financial analysis. The results of five cases are presented in Fig.
7-2. Data for the estimate of plant investment and operating costs are:
1. Plantship direct cost$975 (nom);
2. Annual production1.7 x 108 gal/y of fuel-grade ammonia;
3. Operating and maintenance and shipping costs$16.9M/y;
4. Rate of return on risk-free debt8.00%;
FIG. 7-2. Mossman profitability diagram for 384-MWe OTEC ammonia fuel production.
OTEC CLOSED-CYCLE COST EVALUATION 375
5. Market premium6%;
6. Project equity beta0.83;
7. Permanent financing interest rate13.00%;
8. Construction interest12.00%;
9. Debt as percentage of total capital80%;
10. Wholesale price of ammonia$230/tonne;
11. Marginal tax rate34%;
12. Depreciation schedulebased on the assumption that accelerated depreciation
will be available;
13. Rate of inflationassumed to be zero.
An assessment of the profitability of this option is given in Section 9.1.
FIG. 7-3. Mossman profitability diagram for OTC 50-MWe OTEC electric power production.
FIG. 7-4. Mossman profitability diagram for Japanese 100-MWe OTEC electric power production.
OTEC CLOSED-CYCLE COST EVALUATION 377
FIG. 7-5. Mossman profitability diagram for French 5-MWe OTEC electric power and fresh-water
production.
FIG. 7-6. Mossman profitability diagram for Taiwan 100-MWe OTEC electric power production.
378 OCEAN THERMAL ENERGY CONVERSION
Design studies for land-based OTEC power plants in Taiwan were discussed in
Section 6.4 (Liao et al., 1986). Cost data are listed in Table 7-8. Profitability
estimates for the proposed installation at Chang-Yuan with the long cold-water pipe
are shown in Fig. 7-6.
The economic potential of OTEC fuel and electric power production options
is compared with other existing and proposed alternative sources in Chapter 8.
NOTES
1. Industrial cost surveys show that unit costs of items in commercial production tend to
decrease by a constant factor with each doubling of the number produced; that is, the
second unit cost x times the cost of the first, the 4th x times the cost of the second, and
so on. The factor x is called the "experience factor."
2. In the text, tables, and graphs "$M" signifies "millions of dollars," not "thousands of
dollars," as is conventional in banking terminology.
3. The cost is reduced by the factor 0.93 for each doubling of the number produced.
REFERENCES
Anderson, J. H., 1985. "Ocean thermal powerthe coming energy revolution." Solar and
Wind Technology 2, 25.
Avery, W. H., 1988. "A role for ammonia in the hydrogen economy." Int. J. Hydrogen
Energy 13, 761.
, D. Richards, and G. L. Dugger, 1985. "Hydrogen generation by OTEC electrolysis and
economical transfer to world markets via ammonia and methanol." Int. J. Hydrogen
Energy 10, 727.
Bunch, H. M., 1987. "Comparison of the construction planning and manpower schedules for
building the PD214 general mobilization ship in a U.S. shipyard and in a Japanese
shipyard." J. of Ship Production 1, 25.
, 1988. "Testimony on ship costs, to Commission on Merchant Marine and Defense,
My 18, 1988."
Chang, G. L., 1981. "An introductory study of factors favorable to an OTEC electric power
generating station in Saipan." Proc. 8th Ocean Energy Conf., Washington, D.C., June,
941.
Curto, P. L., and R. Cohen, 1978. "Producer incentives for OTEC commercialization." Proc.
7th OTEC Conf., Washington, D.C., June, II, 77.
Dugger, G. L., J. E. Snyder, and F. Naef, 1982. "Ocean thermal energy conversion: Historical
highlights, status and forecasts." J. of Energy 5, 231.
Fink, L., 1987. "Costs of Navy ship construction." Personal communication to W. H. Avery.
Francis, E. J., and D. Richards, 1983. "OTECStatus and potential of private funding." '82
MTS-IEEE Conf. and Exposition, Washington D.C., Sept., 100.
Gauthier, M., 1986. The economic context of the utilization of the ocean thermal temperature
gradient. IFREMER, Brest, France, May.
George, J. P., and D. Richards, 1980. Baseline designs of moored and grazing 40-MW OTEC
pilot plants. Detailed report. Johns Hopkins University Applied Physics Lab. SR-80A.
OTEC CLOSED-CYCLE COST EVALUATION 379
Gritton, E. C., R. Y. Pei, and J. Aroesty, 1981. "A quantitative evaluation of closed-cycle
OTEC technology in central station applications." Proc. 8th Ocean Energy Conf.,
Washington, D.C., 873.
Homma, T., and H. Kamogawa, 1978. "Conceptual design and economic evaluation of
OTEC power in Japan." Proc. 5th Ocean Thermal Energy Conversion Conf., Miami
Beach, Ha., 2, 161.
Kamogawa, H., and Y. Nakamoto, 1981. "A feasibility study of the OTEC complex for island
applications." Proc. 8th Ocean Energy Conf., Washington, D.C., June, 161.
Liao, T., J. G. Giannnotti, P. R. Van Mater, Jr., and R. A. Lindman, 1986. "Feasibility and
concept design studies for OTEC plants along the east coast of Taiwan, Republic of
China." Proc. International Offshore Mechanics and A rctic Engineering Symp. ,2,618.
Merrow, E. W., K. E. Phillips, and C. M. Myers, 1981. Understanding cost growth and
performance shortfalls in pioneer process plants. RAND Corp., RAND report #2569,
Sept.
Mossman, B. J., 1989. "OTEC methanol plantship proposal: A financial evaluation." Based
on a project in fulfillment of the requirements for the M.B.A. degree from the Wharton
School of the University of Pennsylvania. Document available from the author.
Ocean Thermal Corp., 1984. 40-MWe OTEC power plant. Preliminary design engineering
report. Ocean Thermal Corp., Nov.
Pandolfini, P. P., 1985. OTEC system analysis. Final report. Contract 51352402. Johns
Hopkins Univ. Applied Physics Lab.
Patel, P. S., 1983. Assessment of a 6500-Btu/kWh heat rate dispersed cell generator. Energy
Research Corp., Danbury, Conn., EM-3307
, H. C. Naru, and B. S. Baker, 1982. "Direct molten carbonate fuel cell." National Fuel
Cell Seminar, 1982, 88.
Reid, A. F., 1978. "Ocean thermal energy conversion (OTEC): Temperature increase system
(TIS) assisted." Proc. 5th Ocean Thermal Energy Conversion Conf., Miami Beach, Fla.,
Feb., 59.
SOLARAMCO, 1981. Response to DOE program opportunity notice for 40-MWe OTEC
system- concept. Solar Ammonia Company, Inc., Tulsa, Okla.
8
OTEC ECONOMICS
8.1 INTRODUCTION
The economic contribution that OTEC will make to the solution of the nation's
energy problems depends on its perceived merits relative to existing and alternative
sources of energy and fuels. The previous chapters have shown that OTEC
technology is ready for large-scale demonstrations that will provide a firm basis for
commercial development. OTEC can have a large impact on U.S. energy needs by
supplying liquid fuels for direct use in transportation, or for electric power
production via fuel cells. Its commercial development will depend finally on
political and other factors that cannot be assessed quantitatively. The national
security and environmental impacts of continuing dependence on oil should receive
major emphasis in decisions to implement new processes for fuel production. In this
chapter we review the estimated sales prices of fuels and electric power from
existing and proposed sources and compare them with OTEC prices. Actual
manufacturing costs are generally unavailable and are highly dependent on the
financing methods and resources of the individual producer. However, an objective
comparison of the sales prices of fuels produced by proposed processes can be made
by using the Mossman financial analysis method to estimate the sales price of fuel
or electric power that must be charged for profitable operation. This requires only
information on the plant investment, input fuel costs, and operation and mainte-
nance costs. The sensitivity of the product costs to changes in the estimates in plant
investment can then be displayed in a suitable graph. With this procedure the
alternatives can be equitably compared from a uniform point of view.
8.2.5 Federal, State, and Local Taxes, Licensing Fees, Insurance, and Inciden-
tals
These items are a few percent of plant investment. State and local property taxes will
be zero for sea-based OTEC systems.
Department of Energy, and the National Research Council and on articles published
in the Proceedings of the annual energy technology conferences. The systems
described represent only a small fraction of the current and proposed systems but
are believed to be representative of the range of options. For each option the sales
prices of the direct energy product needed for profitable investment are estimated
from the published estimates of capital cost, fuel costs, and operating and mainte-
nance costs, by using the Mossman financial analysis procedure.
provide the feed stock, followed by purification and catalytic steps to produce
a liquid fuel.
4. Processes based on hydrogen produced by water electrolysis followed by
further reactions to produce a liquid fuel.
FIG. 8-1. Mossman profitability diagram for sale of 1200 bbl/d of motor fuel produced from oil shale.
384 OCEAN THERMAL ENERGY CONVERSION
8.3.6 Alternative Liquid Fuels from Natural Gas Reforming or Coal Gasifica-
tion
Methanol and ammonia can be used directly as motor fuels (Section 7.3). Both are
produced at low cost in large quantities (~ 20 million tons/year in the United States)
by natural gas reforming. A detailed discussion of current processes and estimated
costs for methanol production has been published by McGurl (1990). Estimated
capital costs range from $237M for a U.S.-sited 2500-metric-tons-per-day (mt/d)
methanol plant, to $558M for a 10,000-mt/d plant. Operation and maintenance costs
are estimated to be 6% of fixed costs. These cost estimates are used in determining
the profitability estimates shown in Figs. 8-3(a) and (b). In November 1990 the
average cost of natural gas at the national level was $2.45 per million Btu ($2.457
mB tu) (DOE/EI A, 1991). Methanol prices in barge quantities at the Gulf coast were
in the range $0.60-0.67/gal($25-28/bbl,$9.8-10.9/mBtu) in April 1991 (Chemical
Marketing Reporter, 1991).
Ammonia plant costs are similar to those for methanol. A 1000-mt/d plant
based on natural gas reforming to supply hydrogen and air liquefaction to provide
nitrogen, was estimated to cost $100M (Babbitt, 1981). The financial analysis for
this process is shown in Figs. 8-4(a) and (b). Ammonia in tank-car quantities was
priced at $0.33/gal ($13.9/bbl, $8.3/mBtu) in April 1991 (Chemical Marketing
Reporter, 1991).
Coal gasification to produce fuel-grade methanol appears to be competitive
with natural gas reforming at April 1991 prices (~ $0.65/gal). Large use of methanol
or ammonia in transportation would cause the price of natural gas to increase and
OTEC ECONOMICS 385
FIG. 8-2. Mossman profitability diagram for sale of 83,500 bbl/d of motor fuel produced by the Shell-
FT coal conversion process, (a) Variable plant investment; (b) variable coal price.
would make the preparation of the fuels by coal gasification processes more
competitive. The cost of methanol from coal gasification can be reduced to about
$0.55/gal in a combined process that uses part of the gas for steam electric power
generation (McGurl, 1990).
386 OCEAN THERMAL ENERGY CONVERSION
FIG. 8-3. Mossman profitability diagram for sale of 25,000 mt/d of methanol produced from natural
gas. (a) Variable plant investment; (b) variable gas price.
FIG. 8-4. Mossman profitability diagram for sale of 1000 mt/d of ammonia produced from natural gas.
(a)Variable plant investment; (b) variable gas price.
tion; nuclear, 20.9%; natural gas, 8.3%; hydroelectric power, 8.3%; and petroleum
products, 3.4% (DOE/EIA Monthly Energy Review, 1992). OTEC could be a
significant, environmentally attractive, source of electric power by using OTEC-
produced methanol or ammonia in fuel cells, as discussed in Chapter 7. Prices of
388 OCEAN THERMAL ENERGY CONVERSION
the present and proposed sources of electric power with which it would have to
compete are estimated in this section.
FIG. 8-5. Mossman profitability diagram for sale of electricity produced by 1000-MWe coal combustion
power plants, with FGD. (a) Variable plant investment; (b) variable coal cost.
FIG. 8-6. Mossman profitability diagram for electric power produced in 1000-MWe nuclear power
plants (variable plant investment).
Fuel oil is a convenient source for steam-powered electric plants but has been more
expensive than coal and therefore is used only in cases where the convenience
outweighed the added cost. In the late 1970s construction of new oil plants in the
United States was prohibited, as a means of reducing oil imports. The requirement
for coal plants to incorporate flue gas desulfurization has reduced the cost
advantage for coal, but it is unlikely that new oil plants will be built in the United
States. The capital investments for the existing plants, excluding modifications to
meet environmental requirements, have been amortized. Yan and White present a
graph that indicates that electric power from these plants would cost in the range
of $0.055 -0.07/kW h for fuel oil prices of $20-30/bbl and capacity factors between
0.3 and 0.7 (Yan and White, 1987).
FIG, 8-7, Mossman profitability diagram for electricity produced in a 15-MWe photovoltaic power
plant.
392 OCEAN THERMAL ENERGY CONVERSION
FIG. 8-8. (a) Mossman profitability diagram for electricity produced in 10-MWe central-receiver
solar-thermal power plant, (b) Mossman profitability diagram for electricity produced in 100-MWe
focused-dish solar-thermal power plant, (c) Mossman profitability diagram for electricity produced in
80-MWe cylindrical-mirror solar-thermal power plant.
394 OCEAN THERMAL ENERGY CONVERSION
8.5 COMMENTS
The graphs presented in Chapters 7 and 8 provide information from which the
competitive merits of alternative energy sources may be judged. The data for the
alternative fuel systems presented in Chapter 7 are summarized in Table 8-1. The
data for the representative alternative electric energy sources presented in Chapter
8 are summarized in Table 8-2. The use of the Mossman financial analysis for all
of the systems allows an objective comparison to be made of the ability of each
FIG. 8-9. Mossman profitability diagram for electricity produced in 9-MWe wind-turbine assembly
in Hawaii.
OTEC ECONOMICS 395
FIG. 8-10. Mossman profitability diagram for electricity produced in methanol fuel cells (variable
plant investment).
FIG. 8-11. Mossman profitability diagram for electricity produced in ammonia fuel cells (variable
plant investment).
Table 8-1. Alternative motor fuels price comparison ($1990)" (ITC = 10%; APV = 0)
(1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12)
Number of Investment
Gasoline modules Average Gasoline for 10s bbl/d
Annual Sales price mpg for 10s bbl/d plant Sales price equivalent gasoline
PI Output cost (APV = 0) equivalent gasoline investment (APV = 0) price equivalent
Plant type ($M) Product (gal/y) ($M/y) ($/gaI) ($/gal) equivalent ($B) ($/gal) ($/gal) ($B)
OTEC CH3OH
(coal $50/t) 960 CH3OH 1.99 x 108 51.1 0.70 1.27 13 0.72 0.620 1.12 9.3
OTEC NH3 975 NH, 1.70x 108 25.6 0.74 1.98 24 0.70 0.540 1.44 16.9
Shale oil 225 HCfuel 1.47 x 107 7.5 1.51 1.51 83 0.14 0.662 0.66 12.0
Shell-FT coal
liquefaction
(coal $22.7/t) 4400 HC fuel 1.28x10' 450 0.76 0.76 1 4.32 0.762 0.76 5.2
NG lo CH3OH
(NG $3/raBtu) 237 CH,OH 2.44 x 10* 117 0.58 1.04 6.3 0.19 0.461 0.83 1.7
NG to NH3
(NG $3/mBtu) 100 NH, 1.53x 10s 44 0.37 1.02 26 0.074 0.337 0.93 1.9
system to compete with currently available sources of fuels and electric power,
based on the quoted values of the plant investment, and operating and maintenance
charges. The range of values of plant investment listed for each alternative in Figs.
7-1 to 7-6 and Figs. 8-1 to 8-11 enable one to judge how improvements or
deficiencies in performance or cost, which might result from further research and
development or manufacturing experience, would affect the profitability of a
particular option.
The energy systems discussed in this and the preceding chapter are not of
uniform size. Since construction costs are reduced as component size and numbers
increase, it is desirable to estimate projected product prices based on the same total
output for each system compared. A total system capable of supplying 100,000
barrels per day of fuel equivalent to gasoline in miles per gallon has been chosen
arbitrarily for fuel-production cost estimates. This amount is roughly 1% of daily
U.S. oil imports. Electrical systems designed to produce a total output of 10 billion
kilowatt hours per year are compared. Total electrical power production in the
United States in 1990 was approximately 2800 billion kilowatt hours.
For the estimates listed in columns 8 and 9 of Tables 8-1 and 8-2, a
conservative value of 0.93 for the experience exponent has been selected for all of
the options. This gives a basis for judging the importance of the scaling and
experience factors in comparing the options discussed.
Starting with the plant investment for a particular option, shown in column 2
of Table 8-1, and plant output (module size) shown in column 4, column 8 lists the
number of modules needed to give the desired system output. The number of
doublings needed to reach this number gives the exponent of the experience factor
that is used to calculate the lower plant investment achieved with larger production.
The new sales price of product and equivalent gasoline price are then estimated as
shown in columns 10 and 11. The last column lists the estimated investment for the
total system of a particular type. In Table 8-2 the number of modules needed to
generate the desired electric power output is shown in column 8, the sales price of
electricity in column 9, and the total investment in column 10.
McGurl (1990) quotes a plant investment of $225M for a 2500-ton/d coal
liquefaction plant and $585M for a 12,500-ton/d plant. Thus for this system the
scaling factor is estimated to be 0.6 (that is, a fivefold increase in size increases the
cost by a factor of 2.6 = 5-6). U.S. Navy experience in construction of multiple ship
orders has shown that an experience factor of 0.93, beginning with the second plant,
is appropriate for ship construction (Fink, 1987).
In Tables 8-1 and 8-2 all of the estimates for the costs of multiple units are
based on the use of an experience factor of 0.93. Although the use of these factors
in actual construction estimates would be replaced by values based on engineering
judgments for the particular option, they are worthwhile for the present comparison.
For the OTEC options it is assumed that a size of 200 MWe (nom) will be
optimum for OTEC methanol planlships, and 364 MWe (nom) for ammonia
plantships. Identical modules will be produced to give the required total annual
output. For the land-based liquid-fuel systems it is assumed that plant size will be
scaled up to 100,000 bbl/d gasoline equivalent by constructing identical plants to
OTEC ECONOMICS 399
yield the required total output. Identical 1000-MWe nuclear plants are assumed for
the calculation.
The effects on the national economy of including the fuel and electric power
production options discussed here are presented in Chapter 9.
REFERENCES
Babbitt, J. F. (1981). Closed cycle ocean thermal energy conversion pilot plantGrazing
ammonia plantship. SOLARAMCO, Feb.
Chemical Marketing Reporter, 1991. "Chemical prices." Chemical Marketing Reporter,
New York, N.Y. Verbal quotation.
DOE/EIA Monthly Energy Review, 1989. Washngton, D.C.: U.S. Department of Energy.
Tables 9.1, 9.4, 9.6 (annual average values).
, 1991. Washington, D.C.: U.S. Department of Energy.
, 1992. Washington, D.C.: U.S. Department of Energy. Table 7.1.
Energy Daily, 1989. "DOE unveils 5 year clean-up plan." The Energy Daily, Washington,
D.C.: The King Publishing Group. 17, no. 167.
, 1990. "DOE to get big budget hikes for cleaning up defense programs." The Energy
Daily, Washington, D.C.: The King Publishing Group. 18, no. 8.
Fink, L., 1987. U.S. Maritime Administration (personal communication to W. H. Avery).
Gray, D., and G. Tomlinson, 1989. A review of the economic estimates of coal-derived
transportation fuels documented in the National Research Council report. MITRE
Corp., SAND-89-7089.
Holl, R. J., 1989. Molten salt solar electric experiment. Volume I: Testing, operation and
evaluation. EPRI, GS-6577.
, and D. R. Barren, 1989. Status of solar thermal electric technology. EPRI, GS-65.
International Energy Agency, 1990. Energy and environment: policy overview. Paris,
France: International Energy Agency. 18, no. 24.
Jensen, C. B., 1990. LUZ Corporation, Daggett, Cal. (personal communication to W. H.
Avery).
Jones, G. J., 1987. "Photovoltaic system technology." Proc. Energy Technology Conf. XIV,
Government Institutes, Inc., Rockville, Md., 899.
Lynette, R., 1986. "The California wind farm experience." Proc. Energy Technology Conf.
XIII, Government Institutes, Inc., Rockville, Md., 485.
Maize, K., 1990. "OXY MIS oil shale project wins support in subcommittee." Energy Daily
18, no. 149.
Maycock, P. D., 1987. "Photovoltaic technology: Installed system and module cost." Proc.
Energy Technology Conf. XIV, Government Institutes, Inc., Rockville, Md., 893.
McGurl, G. V., 1990. Assessment of costs and benefits of flexible and alternative fuel use in
the U.S. transportation sector. DOE Pittsburgh Research Center. Center Report.
Montague, J. E., 1981. "Economic viability of solar thermal central-receiver power plants."
Proc. Energy Technology Conf. VIII, Government Institutes, Inc., Rockville, Md.,
1288.
Risser, V. V., and K. W. Stokes, 1987. Photovoltaic field test performance assessment. EPRI,
GS-6251.
Roland, J. R., and D. W. Kearney, 1986. "The world's largest solar electric power plant."
Proc. Energy Technology Conf. XIII, Government Institutes, Inc., Rockville, Md., 449.
Starr, C., 1987. "Technology innovation and energy futures." Proc. Energy Technology
Conf. XIV, Government Institutes, Inc., Rockville, Md., 21.
400 OCEAN THERMAL ENERGY CONVERSION
Tonelson, A., and A. K. Hurd, 1990. Reported in the N.Y. Times, September 4, 1990.
Woods, L. M., 1986. "Fuels from tar sands." Proc. Energy Technology Conf. XIII,
Government Institutes, Inc., Rockville, Md., 1419.
Van Bibber, L. E., and T. S. Andersen, 1986. "Hawaii 9-MWe wind farm: fifteen 600 kW
machines." Proc. Energy Technology Conf. XIII, Government Institutes, Inc., Rockville,
Md., 493.
Yan, T. Y., and J. R. White, 1987. "Economics of electric power generation options and
sulfur dioxide emission control." Proc. Energy Technology Conf. XIV, Government
Institutes, Inc., Rockville, Md., 102.
9
ECONOMIC, ENVIRONMENTAL, AND SOCIAL
ASPECTS OF OTEC IMPLEMENTATION
9.1 ECONOMIC AND SOCIAL BENEFITS OF OTEC COMMERCIAL-
IZATION
The financial analyses presented in Chapters 7 and 8 indicate that commercial
development of OTEC will have a significant impact on the economics of U.S.
energy production and use. Two scenarios for commercial development are
examined in this section:
1. Development of OTEC methanol capacity sufficient to replace all U.S.
gasoline produced from imported oil.
2. Development of OTEC ammonia capacity sufficient to replace all gasoline
used in U.S. transportation.
" The nominal plant investment (PI) for the first plantship is S960M. The PI is calculated from the cost data listed in Table 7-2 assuming discount rate 13%, construction interest 12%. The PI for the second and
third plants is 0.8 times the first plant cost. Thereafter, the plant investment decreases by the factor 0.93 for each doubling of the number produced.
The 200-MWe OTEC CH3OH plantship yield = 1.99 x 108 gal/y of fuel-grade CH3OH.
'' The sales price of methanol is calculated using the Mossman financial analysis with investment and income tax credit of 0%. There is no depreciation allowance. The price is determined by the requirement that
the NPV ^ 0. Note that the lower sales prices for profitability quoted in Chapters 8 and 9 are based on the adjusted present value (APV) and assume that an investment tax credit (ITC) of 10% will be available.
'' In automobile miles/gal, 1.8 gallons CH3OH = 1.0 gallon gasoline. This is based on operating experience.
' The 1990 gasoline price = $0.786/gal (1990 avg. without taxes) (DOE/EIA, Oct. 1991, Table 9.6).
1
The average U.S. gasoline supply in 1990 was 6.96 x 106 bbl/d = 106.6 billion gallons/year (Bgal/y). The crude oil fraction imported was 44.4% or the equivalent of 47.4 Bgal/y of imported gasoline (DOE/EIA,
Oct. 1991, Tables 3.2a, 4). To supply methanol fuel that would give the same automobile mileage requires 47.2 x 1.8/0.199 = 427 OTEC CH3OH plantships.
The average import cost of crude oil (1990) was $21.78/bbl = $0.518/gal. The market price of gasoline was $0.786/gal (1990 avg) (DOE/EIA, Oct. 1991). The refinery markup = $(0.786 - 0.518)/gal = $0.270/
gal. The "real cost" of imported oil to the U.S. economy = 2.1 x market price (National Defense Council Foundation, abstracted by Freudmann,1988). Therefore, the real cost of crude was $21.78/bbl x 2.1 -
S45.7/bbl = $ 1.088/gal. Thus, the real cost of gasoline derived from imported oil was $ I.088 + 0.270)/gal = $1.358/gal versus the market price of $0.786/gal.
" A study by the Commission on Engineering and Technical Systems (1990) arrived at an added cost of $2.5/bbl (S0.0595/gal) oil equivalent to adapt automobiles in production to use methanol as a fuel in place
of gasoline.
' A tax of $70 per ton of carbon emitted was recommended by the United Nations Intergovernmental Panel on Climate Change (1984). This corresponds to $0.173/gal of gasoline used, and $0.158/gal of methanol
for equivalent automobile mileage.
1
It is assumed that by 2030 all U.S. gasoline will be priced at a value equivalent to the 1990 real cost of imported oil.
404 OCEAN THERMAL ENERGY CONVERSION
have a small negative value of the NPV until 256 are produced, after which the
national economy is benefited.
The nearly neutral impact of OTEC commercialization on the national economy,
shown in Table 9-1, suggests examination of the profitability of industrial production
of OTEC plantships if a government commitment is made to support OTEC via a 10%
investment tax credit. The financing rationale of Mossman that was explained in
Chapter 7 is used. The results are presented in Table 9-2.
According to the analysis, methanol plantship production will be profitable
beginning with the third plantship if the economic gains of reducing oil imports and
the environmental benefits of lowered carbon emissions are quantified and in-
cluded. When the total production of 427 plantships needed to replace imported oil
is operational, the net profit to the investors using the Mossman financing plan will
be $18B/y after taxes.
Liquid ammonia is an automobile fuel that has a high octane number (111) and
burns efficiently in automobile engines. It produces only water and nitrogen as
products of combustion and can meet future U.S. transportation requirements for
a technically feasible, nonpolluting automobile fuel that does not produce CO2-
The physical properties of ammonia are nearly the same as those of liquid
propane (bottled gas), and the requirements for automobile storage and handling
will be similar. It is estimated that 2.67 gallons of liquid ammonia will give the same
automobile mileage as a gallon of gasoline. A 368-MWe OTEC ammonia plantship
will produce 170 million gallons of liquid ammonia fuel per year. Thus, 1681
plantships will supply enough fuel to replace the 107 billion gallons of gasoline
used in the United States in 1990. The nominal plantship investment is $975M. The
average investment per ammonia plantship for the total production would be
$446M.
9.1.2.1 Schedule
A national goal to replace all U.S. gasoline and ammonia fuel, by the year 2050,
could be established to comply with world desires to keep carbon emissions low
enough to stabilize CO2 buildup in the atmosphere. This would require an annual
production of 30 ammonia plantships. A reasonable extension of U.S. shipbuilding
capabilities would accomplish this.
9.1.2.2 Financing
The costs and benefits of a large-scale ammonia fuel program are similar to those
outlined in the discussion of OTEC methanol financing. The principal differences
are that replacement of gasoline with ammonia fuel would entirely eliminate carbon
emissions, with a corresponding economic benefit. A larger automobile adaptation
cost than that required for methanol fuel would be associated with storage,
handling, and use of the liquefied ammonia fuel. Ammonia can also be used in fuel
cells for electricity generation.
Table 9-2. Profit to investors replacing U.S. gasoline requiring oil imports, with methanol produced on OTEC plantships
(discount rate = 13%; construction interest = 12%; ITC = 10%; APV = 0)
CH3OH Savings CH3OH Net profit
nth Gasoline equiv. using Gasoline price to investors
CH3OH CH3OH Total CH3OH Equiv. Gasoline "real price" price incl. CH3OH price incl. incl. auto replacing
plant total Avg. CH3OH sales gasoline market Gasoline with import auto to replace import and cost and gaso. by
Plant Relative PF PI PI prod.* price' price"* price" replaced^ impact8 costs'1 gasoline carbon tax'carbon tax' CH3OH7
no. cost Sum ($M) ($B) ($M) (Bgal/y) ($/gal) ($/gal) ($/gal) (Bgal/y) ($/gaI) ($/gal) ($B/y) ($/gal) ($/gal) ($B/y)
1 1.000 1.00 960 0.96 960 0.20 0.75 1.34 0.79 0.11 1.36 1.40 0.00 1.53 1.56 -0.003
2 0.800 1.80 768 1.73 864 0.40 0.70 1.25 0.79 0.22 1.36 1.31 0.01 1.53 1.47 0.013
3 0.800 2.60 768 2.50 832 0.60 0.68 1.23 0.79 0.33 1.36 1.29 0.02 1.53 1.44 0.029
4 0.744 3.34 714 3.21 803 0.80 0.67 1.20 0.79 0.44 1.36 1.26 0.04 1.53 1.42 0.051
8 0.692 6.32 664 6.07 758 1.6 0.64 1.15 0.79 0.88 1.36 1.21 0.13 1.53 1.37 0.143
16 0.64 11.9 618 11.4 711 3.2 0.62 1.12 0.79 1.77 1.36 1.18 0.32 1.53 1.33 0.35
32 0.60 22.2 575 21.3 665 6.4 0.60 1.07 0.79 3.54 1.36 1.13 0.79 1.53 1.29 0.85
64 0.56 41.3 534 39.6 620 13 0.58 1.04 0.79 7.08 1.36 1.09 1.86 1.53 1.25 1.97
128 0.52 76.9 497 73.8 577 25 0.55 1.00 0.79 14.15 1.36 1.05 4.29 1.53 1.21 4.50
256 0.48 143 462 137 537 51 0.53 0.96 0.79 28.30 1.36 1.02 9.60 1.53 1.18 10.0
427 0.46 225 438 216 507 85 0.52 0.93 0.79 47.21 1.36 0.99 17.3 1.53 1.15 18.0
512 0.45 266 430 256 500 102 0.51 0.93 0.79 56.60 1.36 0.98 21.1 1.53 1.14 22.0
" The nominal plant investment (PI) for the first plantship is S960M. The PI is calculated from the cost data listed in Table 7-2 assuming discount rate 13%, construction interest 12%. The PI for the second and
third plants is 0.8 times the first plant cost. Thereafter, the plant investment decreases by the factor 0.93 for each doubling of the number produced.
6
The 200-MWe OTEC CH,OH plantship yield = 1.99 x 10s gal/y of fuel-grade CH,OH.
'-' The sales price of methanol is calculated using the Mossman financial analysis with investment tax credit (ITC) of 10%. Note that the lower sales prices for profitability quoted in Chapters 8 and 9 are based on
the adjusted present value (APV) and assume that an ITC of 10% will be available.
'' In automobile miles/gal, 1.8 gallons CH3OH = 1.0 gallon gasoline. This is based on operating experience.
* The 1990 gasoline price = $0.786/gal (1990 avg, without taxes) (DOE/EIA, Oct. 1991, Table 9.6).
'" The average U.S. gasoline supply in 1990 was 6.96 x 106 bbl/d = 106.6 Bgal/y. The crude oil fraction imported was 44.4% or the equivalent of 47.4 Bgal/y of imported gasoline (DOE/EIA, Oct. 1991, Tables
3.2a, 4). To supply methanol fuel that would give the same automobile mileage requires 47.2 x 1.8/0.199-427 OTEC CH3OH plantships.
The average import cost of crude oil (1990) was $21.78/bbl = $0.518/gal The market price of gasoline was $0.786/gal (1990 avg) (DOE/EIA, Oct. 1991). The refinery markup = $(0.786 - 0.5 3 8)/gal = S0.270/
gal. The "real cost" of imported oil to the U.S. economy = 2.1 x market price (National Defense Council Foundation, abstracted by Freudmann,1988). Therefore, the real cost of crude was $21.78/bbl x 2.1 =
$45.7/bbl = S!.088/gal. Thus, the real cost of gasoline derived from imported oil was Si.088 + 0.270)/gal - $1.358/ga1 versus the market price of $0.786/gal.
'; A study by the Commission on Engineering and Technical Systems (1990) arrived at an added cost of $2.5/bbl (S0.0595/gal) oil equivalent to adapt automobiles in production to use methanol as a fuel in place
of gasoline.
1
A tax of $70 per ton of carbon emitted was recommended by the United Nations Intergovern mental Panel on Climate Change (1984). This corresponds to $0.173/gal of gasoline used, and $0.158/gal of methanol
for equivalent automobile mileage.
' It is assumed that by 2030 all U.S. gasoline will be priced at a value equivalent to the 1990 real cost of imported oil.
406 OCEAN THERMAL ENERGY CONVERSION
9.1.2.3 Conclusions
Several significant conclusions about the feasibility of establishing an OTEC
commercial industry are evident from the analyses presented. Their validity is
supported by production and operational experience gained in the U.S. and foreign
shipbuilding and chemical engineering industries.
1. Economic and social gains can be achieved at modest cost to the United States
by large-scale substitution of OTEC methanol for gasoline made from im-
ported oil, as shown in Table 9-1. The program will be financially attractive to
investors with customary investment incentives, netting investors $18B/y
when plantship production reaches 427 plantships, as shown in Table 9-2.
2. Large social gains resulting from the elimination of carbon emissions from
U.S. automobiles can be achieved at reasonable cost by replacing gasoline with
ammonia fuel (Table 9-3). An OTEC program that replaces all gasoline used
in U.S. automobiles by ammonia, with customary investment incentives, will
be financially attractive, netting investors a return of $23B per year when the
total production is established (Table 9-4).
3. The cost estimates are sensitive to the values judged to be reasonable for
discount rates and construction interest. For example, as shown in Tables 9-5
to 9-8, use of a discount rate of 11% and construction interest of 10% in the
Mossman analysis yields a net economic value of $9B/y to the national
economy for the 427 methanol plantship production, and profit to the investors
of $22B/y. For ammonia plantship production the economic value (NPV) is
slightly negative with the lower interest rates until the 500th plantship is
produced and then rises to $1 IB/y when plantship number 1681 is delivered.
The annual profits to investors (APV) is $38B at this time. For this case, the
difference in savings to the national economy associated with the lower
discount rate is $45B/y when full plantship production is achieved, and the net
difference to investors increases to $38B/y.
The large difference in the financial benefits associated with the small
differences in the assumed interest rates is important to note. The lower interest
rates are typical of recent values (1990), but rates will change to higher or lower
Table 9-3. Economic impact of replacing U.S. gasoline with ammonia automobile fuel produced on OTEC plantships
(discount rate = 13%; ITC = 0: NPV = 0)
Gasoline NH3 equiv. Gasoline Saving to U.S.
iith NH3 NH3 Total NH3 Equiv. Gasoline "real price" price incl. price incl. economy using
plant total Avg. NH3 sales gasoline market price" Gasoline with import auto import and NH3 to replace
Plant Relativt: in'festmenl V PI PI prod.b price' price'' ($/gal) replaced^ impact^ costs* carbon tax' gasoline'
no. cost Sum ($M) ($B) ($M) (Bgal/y) ($/gal) ($/gal) (1990 avg) (Bgal/y) ($/gal) ($/gal) ($/gal) ($B/y)
1 1.000 1.00 975 0.98 975 0.17 1.17 3.12 0.79 0.06 1.36 3.42 1.53 -0.12
2 0.800 1.80 780 1.76 878 0.34 1.06 2.84 0.79 0.13 1.36 3.14 1.53 -0.20
3 0.800 2.60 780 2.54 845 0.51 1.03 2.74 0.79 0.19 1.36 3.04 1.53 -0.29
4 0.744 3.34 725 3.26 815 0.68 0.99 2.65 0.79 0.25 1.36 2.95 1.53 -0.36
8 0.692 6.32 675 6.16 770 1.36 0.94 2.51 0.79 0.51 1.36 2.81 1.53 -0.65
16 0.643 11.9 627 11.6 722 2.72 0.89 2.37 0.79 1.02 1.36 2.67 1.53 -1.2
32 0.598 22.2 583 21.6 675 5.44 0.84 2.23 0.79 2.04 1.36 2.53 1.53 -2.0
64 0.557 41.3 543 40.3 629 10.9 0.78 2.09 0.79 4.07 1.36 2.39 1.53 -3.5
128 0.518 76.9 505 75.0 586 21.8 0.74 1.96 0.79 8.15 1.36 2.26 1.53 -6.0
256 0.481 143 469 140 545 43.5 0.69 1.84 0.79 16.3 1.36 2.14 1.53 -10.0
512 0.448 266 436 260 507 87.0 0.65 1.73 0.79 32.6 1.36 2.03 1.53 -16.2
1024 0.416 496 406 483 472 174 0.61 1.62 0.79 65.2 1.36 1.92 1.53 -25.6
1681 0.395 769 385 750 446 286 0.58 1.55 0.79 107 1.36 1.85 1.53 -33.7
" The nominal plant investment (PI) for the first plantship is S975M. The PI is calculated from the cost data listed in Table 7-2 assuming discount rate 13%, construction interest 12%. The PI for the second and
third plants is 0.8 times the first plant cost. Thereafter, the plant investment decreases by the factor 0.93 for each doubling of the number produced.
* The 368-MWe OTEC NH3 plantship yield of fuel-grade NH3 = 1.70 x 10s gal/y.
' The sales price of ammonia is calculated using the Mossman financial analysis with investment and income tax credit of 0%. There is no depreciation allowance. The price is determined by the requirement that
the NPV 5 0.
d
In automobile miles/gal, 2.67 gallons NH3 - 1.0 gallon gasoline, assuming the same benefit from high octane number that was found for CH3OH.
' The 1990 gasoline price = $0.786/gal( 1990 avg. without taxes) (DOE/EIA, Oct. 1991, Table9.6).
' The average U.S. gasoline supply in 1990 was 6.96 x 10* bbl/d = 107 Bgal/y (DOE/EIA, Oct. 1991, Tables 3.2a, 4). To supply ammonia fuel that would give the same total automobile mileage requires (107 x
2.67X0.1 i= 1681 OTEC NH3 plantships.
The average import cost of crude oil (1990) was $21.78/bbl = $0.518/gal. The "real cost" of imported oil to the U.S. economy = 2.1 x market price (National Defense Council Foundation, abstracted by Freudmann,
1988). Therefore, the real cost of imported oil was $45.7/bbl ($1.088/gal). The market price of gasoline was $0.786/gal (1990 avg) (DOE/EIA, Oct. 1991). Thus there was a refinery markup between oil cost and
the sales price of S(0.786 - 0.518)/gal = $0.270/gal.. The "real" price of imported oil was, then, $(0.278 + 1.088)/gal = $1.358/gal.
' A study by the Commission on Engineering and Technical Systems (3990) arrived at an added cost of $11.11/bbl ($0.254/gal oil equivalent) to adapt automobiles in production to use compressed natural gas
as a fuel to replace gasoline. Ammonia fuel would have simpler storage and less volume but would need a modified fuel system. This suggests a cost increment of $0.30/gal (gasoline equivalent) above the gasoline
market price as the ammonia fuel price for automobile use.
' A tax of $70 per ton of carbon emitted in energy production was recommended by the United Nations Intergovernmental Panel on Climate Change (1984). This corresponds to $0.173/gal of gasoline used in
transportation versus zero dollars per gallon of ammonia for equivalent automobile mileage.
;
It is assumed that by 2030 all U.S. gasoline will be priced at a value equivalent to the 1990 real cost of imported oil.
Table 9-4. Profit to investors replacing gasoline used in U.S. automobiles with ammonia vehicle fuel
(discount rate = 13%; construction interest = 12%; ITC = 10%; APV = 0)
Gasoline NH3 equiv. Gasoline Profit to
nth NH3 NH3 Total NH3 Equiv. Gasoline "real price" price incl. real cost investors using
plant total Avg. NH3 sales gasoline market price'1 Gasoline with import auto plus NH3 to replace
Plant Relative investment1 PI PI prod.* price' price'' ($/gal) replacedf impact^ costs* carbon taxi gasolinej
no. cost Sum ($M) ($B) ($M) (Bgal/y) ($/gal) ($/gal) (1990 avg) (Bgal/y) ($/gal) ($/gal) ($/gal) ($B/y)
1 1.000 1.00 975 0.98 975 0.17 0.743 1.98 0.79 0.06 1.36 2.28 1.53 -0.05
2 0.800 1.80 780 1.76 878 0,34 0.673 1.98 0.79 0.13 1.36 2.28 1.53 -0.10
3 0.800 2.60 780 2.54 845 0.51 0.649 1.80 0.79 0.19 1.36 2.10 1.53 -0.11
4 0.744 3.34 725 3.26 815 0.68 0.628 1.73 0.79 0.25 1.36 2.03 1.53 -0.13
8 0.692 6.32 675 6.16 770 1.36 0.596 1.68 0.79 0.51 1.36 1.98 1.53 -0.23
16 0.643 11.9 627 11.6 722 2.72 0.561 1.59 0.79 1.02 1.36 1.89 1.53 -0.4
32 0.598 22.2 583 21.6 .675 5.44 0.527 1.50 0.79 2.04 1.36 1.80 1.53 -0.5
64 0.557 41.3 543 40.3 629 10.9 0.494 1.41 0.79 4.07 1.36 1.71 1.53 -0.7
128 0.518 76.9 505 75.0 586 21.8 0.464 1.32 0.79 8.15 1.36 1.62 1.53 -0.7
256 0.481 143 469 140 545 43.5 0.434 1.24 0.79 16.3 1.36 1.54 1.53 -0.1
512 0.448 266 436 260 507 87.0 0.407 1.16 0.79 32.6 1.36 1.46 1.53 2.4
1024 0.416 496 406 483 472 174 0.382 1.09 0.79 65.2 1.36 1.39 1.53 9.4
1681 0.395 769 385 750 446 286 0.363 1.02 0.79 107 1.36 1.32 1.53 22.6
" The nominal plant investment (PI) for the first plantship is $975M. The PI is calculated from the cost data listed in Table 7-2 assuming discount rate 13%, construction interest 12%. The PI for the second and
third plants is 0.8 times the first plant cost. Thereafter, the plant investment decreases by the factor 0.93 for each doubling of the number produced.
b
The 368-MWe OTEC NH3 plantship yield of fuel-grade NH. = 1.70 x 10s gal/y.
1
The sales price of ammonia is calculated using the Mossman financial analysis with ITC of 10%. There is no depreciation allowance. The price is determined by the requirement that the APV ? 0.
' In automobile miles/gal, 2.67 gallons NH3 - 1.0 gallon gasoline, assuming the same benefit from high octane number that was found for CH3OH.
" The 1990 gasoline price = $0.786/gal (1990 avg. without taxes) (DOE/EIA, Oct. 1991, Table 9.6).
:
The average U.S. gasoline supply in 1990 was 6.96 x 106bbl/d = 107 Bgal/y (DOE/EIA, Oct. 1991, Tables 3.2a, 4). To supply ammonia fuel that would give the same total automobile mileage requires (107 x
2.67)/0.17 = 1681 OTEC NH3 plantships.
" The average import cost of crude oil (1990) was $21.78/bbl = $0.5 3 8/gal. The "real cost" of imported oil to the U.S. economy = 2.1 x market price (National Defense Council Foundation, abstracted by Freudmann,
1988). Therefore, the real cost of imported oil was $45.7/bbl ($1.088/gal). The market price of gasoline was $0.786/gal (1990 avg) (DOE/EIA, Oct. 1991). Thus there was a refinery markup between oil cost and
the sales price of $(0.786 0.5l8)/gal-$0.270/gal.. The "real" price of imported oil was, then, $(0.278 + 1.088)/gal = $1.358/gal. The difference in ammonia production between the next-to-last and last rows
is used to replace gasoline produced in the U.S. Therefore, the real price of gasoline for this increment is the market price.
' A study by the Commission on Engineering and Technical Systems (1990) arrives at an added cost of $11.11/bbl ($0.254/gal oil equivalent) to adapt automobiles in production to use compressed natural gas
as a fuel to replace gasoline. Ammonia fuel would have simpler storage and less volume but would need a modified fuel system. This suggests a cost increment of $0.30/gal (gasoline equivalent) above the gasoline
market price as the ammonia fuel price for automobile use.
1
A tax of S70 per ton of carbon emitted in energy production was recommended by the United Nations Intergovernmental Panel on Climate Change (1984). This corresponds to $0.173/gal of gasoline used in
transportation versus zero dollars per gallon of ammonia for equivalent automobile mileage.
' It is assumed that by 2030 all U.S. gasoline will be priced at a value equivalent to the 1990 real cost of imported oil.
Table 9-5. Economic impact of replacing U.S. gasoline requiring oil imports, with methanol produced on OTEC plantships
(discount rate = 11%; construction interest = 10%; ITC = 0; NPV = 0)
Net saving
CH3OH Savings CH3OH to U.S.
nth Gasoline equiv. using Gasoline price economy in
CH3OH CH3OH Total CH3OH Equiv. Gasoline "real price" price incl. CH3OH price incl. incl. auto replacing
plant total Avg. CH3OH sales gasoline market Gasoline with import auto to replace import and cost and gaso. by
Plant Relative PI" PI PI prod.* pricee priced pricee replacedf impactg costs* gasoline carbon tax'carbon tax' CH3OHJ
no. cost Sum ($M) ($B) ($M) (Bgal/y) ($/gal) ($/gal) ($/gal) (Bgal/y) ($/gal) ($/gal) ($B/y) ($/gal) ($/gal) ($B/y)
1 1.000 1.0 918 0.96 960 0.20 0.95 1.70 0.79 0.11 1.36 1.76 -0.04 1.53 1.92 -0.04
2 0.800 1.8 826 1.73 864 0.40 0.88 1.58 0.79 0.22 1.36 1.64 -0.06 1.53 1.80 -0.06
3 0.800 2.6 796 2.50 832 0.60 0.86 1.54 0.79 0.33 1.36 1.60 -0.08 1.53 1.76 -0.07
4 0.744 3.3 767 3.21 803 0.80 0.83 1.50 0.79 0.44 1.36 1.56 -0.09 1.53 1.72 -0.08
8 0.692 6.3 725 6.07 758 1.59 0.80 1.44 0.79 0.88 1.36 1.50 -0.13 1.53 1.66 -0.12
!6 0.643 11.9 680 11.4 711 3.18 0.77 1.38 0.79 1.77 1.36 1.44 -0.15 1.53 1.60 -0.12
32 0.598 22.2 635 21.3 665 6.37 0.74 1.32 0.79 3.54 1.36 1.38 -0.09 1.53 1.54 -0.03
64 0.557 41.3 592 39.6 620 12.7 0.70 1.27 0.79 7.08 1.36 1.32 0.23 1.53 1.48 0.34
128 0.518 76.9 552 73.8 577 25.5 0.67 1.21 0.79 14.2 1.36 1.27 1.23 1.53 1.43 1.44
256 0.481 143.2 513 137 537 50.9 0.64 1.16 0.79 28.3 1.36 1.22 3.94 1.53 1.38 4.37
427 0.456 225.5 485 216 507 85.0 0.62 1.12 0.79 47.2 1.36 1.18 8.36 1.53 1.34 9.07
512 0.448 266.4 478 256 500 102 0.62 1.11 0.79 56.6 1.36 1.17 10.53 1.53 1.33 11.38
" The nominal plant investment (PI) for the first piantship is S960M. The PI is calculated from the cost data listed in Table 7-2 assuming discount rate 11%, construction interest 10%. The PI for the second and
third plants is 0.8 times the first plant cost. Thereafter, the plant investment decreases by the factor 0.93 for each doubling of the number produced.
' The 200-MWe OTEC CH,OH piantship yield = 1.99 x 10 gal/y of fuel-grade CH,OH.
' The sales price of methanol is calculated using the Mossman financial analysis with investment and income tax credits of 0%. There is no depreciation allowance. The price is determined by the requirement that
the NPV S 0. Note that the lower sales prices for profitability quoted in Chapters 8 and 9 are based on the adjusted present value (APV) and assume that an ITC of 10% will be available.
'' In automobile miles/gal, 1.8 gallons CH.OH = 1.0 gallon gasoline. This is based on operating experience.
' The 1990 gasoline price = $0.786/gal (1990 avg. without taxes) (DOE/EIA, Oct. 1991, Table 9.6).
' The average U.S. gasoline supply in 1990 was 6.96 x 10" bbl/d = 106.6 Bgal/y. The crude oil fraction imported was 44.4% or the equivalent of 47.4 Bgal/y of imported gasoline (DOE/EIA, Oct. 1991, Tables
3.2a, 4). To supply methanol fuel that would give the same automobile mileage requires 47.2 x 1.8/0.199 = 427 OTEC CH,OH plantships.
x The average import cost of crude oil (1990) was $21.78/bbl = $0.518/gal. The market price of gasoline was $0.786/gal (1990 avg) (DOE/EIA, Oct. 1991). The refinery markup = $(0.786 - 0.518)/gal = S0.270/
gal. The "real cost" of imported oil to the U.S. economy - 2.1 x market price (National Defense Council Foundation, abstracted by Freudmann,1988). Therefore, the real cost of crude was $21.78/bbl x2.1 -
$45,7/bbl = $1.088/gal. Thus, the real cost of gasoline derived from imported oil was $ 1.088 + 0.270)/gal = $ 1.358/gal versus the market price of $0.786/gal.
' ' A study by the Commission on Engineering and Technical Systems (1990) arrived at an added cost of $2.5/bbI ($0.0595/gal) oil equivalent to adapt automobiles in production to use methanol as a fuel in place
of gasoline.
' A tax of $70 per ton of carbon emitted was recommended by the United Nations Intergovernmental Panel on Climate Change (1984). This corresponds to $0.173/gal of gasoline used, and $0.158/gal of methanol
for equivalent automobile mileage.
1
It is assumed that by 2030 all U.S. gasoline will be priced at a value equivalent to the 1990 real cost of imported oil.
Table 9-6. Profit to investors replacing U.S. gasoline requiring oil imports, with methanol produced on OTEC plantships
(discount rate =11%; construction interest =10%; ITC = 10%; APV = 0)
Savings CH3OH Net profit to
nth Gasoline CH3OH using Gasoline price investors of
CH3OH CH3OH Total CH3OH Equiv. Gasoline "real price" price incl. CH3OH price incl. incl. auto replacing
plant total Avg. CH3OH sales gasoline market Gasoline with import auto to replace import and cost and gaso. by
Plant Relative PF PI PI prod.b pricec priced pricee replacedf impactg costsh gasoline carbon taxi carbon tax1 CH3OHJ
no. cost Sum ($M) ($B) ($M) (Bgal/y) ($/gal) ($/gal) Cf/gal) (Bgal/y) ($/gal) ($/gal) ($B/y) ($/gal) ($/gal) ($B/y)
1 1.000 1.0 918 0.92 918 0.20 0.69 1.24 0.79 0.11 1.36 1.30 0.01 1.53 1.45 0.01
2 0.800 1.8 826 1.65 826 0.40 0.64 1.15 0.79 0.22 1.36 1.21 0.03 1.53 1.37 0.04
3 0.800 2.6 796 2.39 796 0.60 0.63 1.13 0.79 0.33 1.36 1.19 0.06 1.53 1.34 0.06
4 0.744 3.3 767 3.07 767 0.80 0.61 1.10 0.79 0.44 1.36 1.16 0.09 1.53 1.32 0.09
8 0.692 6.3 725 5.80 725 1.59 0.59 1.06 0.79 0.88 1.36 1.12 0.21 1.53 1.28 0.22
16 0.643 11.9 680 10.88 680 3.18 0.57 1.02 0.79 1.77 1.36 1.08 0.49 1.53 1.24 0.51
32 0.598 22.2 635 20.33 635 6.37 0.55 0.98 0.79 3.54 1.36 1.04 1.11 1.53 1.20 1.16
64 0.557 41.3 592 37.91 592 12.7 0.53 0.95 0.79 7.08 1.36 1.01 2.49 1.53 1.16 2.59
128 0.518 76.9 552 70.61 552 25.5 0.51 0.91 0.79 14.2 1.36 0.97 5.49 1.53 1.13 5.70
256 0.481 143.2 513 131.43 513 50.9 0.49 0.87 0.79 28.3 1.36 0.93 11.99 1.53 1.09 12.42
427 0.456 225.5 485 207.00 485 85.0 0.47 0.85 0.79 47.2 1.36 0.91 21.11 1.53 1.07 21.81
512 0.448 266.4 478 244.56 478 102 0.47 0.84 0.79 56.6 1.36 0.90 25.72 1.53 1.06 26.56
" The nominal plant investment (PI) for the first plantship is S960M. The PI is calculated from the cost data listed in Table 7-2 assuming discount rate 11 %, construction interest 10%. The Pi for the second and
ihird plants is 0.8 times the first plant cost. Thereafter, the plant investment decreases by the factor 0.93 for each doubling of the number produced.
* The 200-MWc OTEC CH3OH plantship yield = 1.99 x 108 gal/y of fuel-grade CH3OH.
' The sales price of methanol is calculated using the Mossman financial analysis with ITC of 10%. There is no depreciation allowance. The price is determined by the requirement that the NPV !> 0. Note that the
lower sales prices for profitability quoted in Chapters 8 and 9 are based on the adjusted present value (APV) and assume that an ITC of 10% will be available.
'' In automobile miles/gal, 1.8 gallons CH3OH =1.0 gallon gasoline. This is based on operating experience.
< The 1990 gasoline price = $0.786/gal (1990 avg. without taxes) (DOE/EIA, Oct. 1991, Table 9.6).
f
The average U.S. gasoline supply in 1990 was 6.96 x 106 bbl/d = 106.6 Bgal/y. The crude oil fraction imported was 44.4% or the equivalent of 47.4 Bgal/y of imported gasoline (DOE/EIA, Oct. 1991, Tables
3.2a, 4). To supply methanol fuel that would give the same automobile mileage requires 47.2 x 1.8/0.199 = 427 OTEC CH3OH plantships.
* The average import cost of crude oil (1990) was $21.78/bbl = $0.518/gal. The market price of gasoline was $0.786/gal (1990 avg) (DOE/EIA, Oct. 1991). The refinery markup = $(0.786 - 0.518)/gal = S0.270/
gal. The 'Yea! cost" of imported oil to the U.S. economy = 2.1 X market price (National Defense Council Foundation, abstracted by Freudmann,1988). Therefore, the real cost of crude was $21.78/bbl x 2.1 =
$45.7/bbl = $1.088/gal. Thus, the real cost of gasoline derived from imported oil was $1.088 + 0.270)/gal = $!.358/gal versus the market price of $0.786/gal.
" A study by the Commission on Engineering and Technical Systems (1990) arrived at an added cost of $2.5/bbl ($0.0595/gal) oil equivalent to adapt automobiles in production to use methanol as a fuel in place
of gasoline.
' A tax. of $70 per ton of carbon emitted was recommended by the United Nations Intergovernmental Panel on Climate Change (1984), This corresponds to $0.173/gal of gasoline used, and $0.158/gal of methanol
for equivalent automobile mileage.
J
It is assumed that by 2030 all U.S. gasoline will be priced at a value equivalent to the 3 990 real cost of imported oil.
Table 9-7. Economic impact of replacing U.S. gasoline with ammonia automobile fuel produced on OTEC plantships
(discount rate =11%; construction interest = 10%; NPV = 0)
Gasoline NH3 equiv. Gasoline Savings to U.S.
nth NH3 NH3 Total NH3 Equiv. Gasoline "real price" price incl. real cost economy using
plant total Avg. NH3 sales gasoline market pricee Gasoline with import auto plus NH3 to replace
Plant Relative investment" PI PI prod.b pricec priced t$/gal) replacedf impactg' costsh carbon taxi gasoline'
no. cost Sum ($M) ($B) ($M) (Bgal/y) ($/gal) ($/gal) (1990 avg) (Bgal/y) ($/gal) ($/gal) ($/gal) ($B/y)
1 1 .000 1.00 975 0.98 975 0.17 0.93 2.470 0.786 0.064 1 .358 2.770 1.648 -0.07
2 0.800 1.80 780 1.76 878 0.34 0.84 2.243 0.786 0.127 1.358 2.543 1.648 -0.11
3 0.800 2.60 780 2.54 845 0.51 0.81 2.171 0.786 0.191 1.358 2.471 1.648 -0.16
4 0.744 3.34 725 3.26 815 0.68 0.79 2.099 0.786 0.255 1.358 2.399 1.648 -0.19
8 0.692 6.32 675 6.16 770 1.36 0.75 1.994 0.786 0.509 1.358 2.294 1.648 -0.33
16 0.643 11.86 627 11.56 722 2.72 0.71 1.885 0.786 1.019 1.358 2.185 1.648 -0.55
32 0.598 22.15 583 21.60 675 5.44 0.67 1.776 0.786 2.037 1.358 2.076 1.648 -0.87
64 0.557 41.30 543 40.27 629 10.88 0.63 1.669 0.786 4.075 1.358 1.969 1.648 -1.31
128 0.518 76.92 505 75.00 586 21.76 0.59 1.570 0.786 8.150 1.358 1.870 1.648 -1.81
256 0.481 143.17 469 139.59 545 43.52 0.55 1.477 0.786 16.300 1.358 1.777 1.648 -2.09
512 0.448 266.40 436 259.74 507 87.04 0.52 1.388 0.786 32.599 1.358 1.688 1.648 -1.32
1024 0.416 495.61 406 483.22 472 174.08 0.49 1.306 0.786 65.199 1.358 1.606 1.648 2.76
1681 0.395 769.13 385 749.91 446 285.77 0.47 1.247 0.786 107.030 1.358 1.547 1.648 10.82
" The nominal plant investment (PI) for the first plantship is S975M. The PI is calculated from the cost data listed in Table 7-3 assuming discount rate 11 %, construction interest 10%. The PI for the second and
third plants is 0.8 times the first plant cost. Thereafter, the plant investment decreases by the factor 0.93 for each doubling of the number produced.
'' The 368-MWe OTEC NH, plantship yield of fuel-grade NH3 = 1.70 x 108 gal/y.
' The sales price of ammonia is calculated using the Mossman financial analysis with investment and income tax credit of 0%. The price is determined by the requirement that the NPV =S 0. Note that the financial
analysis assumes 20% equity and 80% debt.
'' In automobile miles/gal, 2.67 gallons NK, = 1.0 gallon gasoline, assuming the same benefit from high octane number that was found for CH3OH.
' The 1990 gasoline price = S0.786/gal (1990 avg. without taxes) (DOE/EIA, Oct. 1991, Table 9.6).
' The average U.S. gasoline suppiy in 1990 was 6.96 x 106 bbl/d = 107 Bgal/y (DOE/EIA, Oct. 1991, Tables 3.2a, 4). To supply ammonia fuel that would give the same total automobile mileage requires (107 x
2.67)/0.17 = 1681 OTEC NH3 plantships.
v
The average import cost of crude oil (1990) was $21.78/bbI = $0.5 f 8/gal. The "real cost" of imported oil to the U.S. economy = 2.1 x market cost (National Defense Council Foundation, abstracted by Freudmann,
1988). Therefore, the real cost of imported oil was $45.7/bbl ($ 1.088/gaI). The market price of gasoline was $0.786/gal (1990 avg) (DOE/EIA, Oct. 1991). Thus there was a refinery markup between oil cost and
the sales price of 5(0.786 - 0.518)/gal = $0.270/gal.. The "real" price of imported oil was, then, $(0.278 + 3.088)/gal = $ 1.358/gal.
'' A study by the Commission on Engineering and Technical Systems (1990) arrives at an added cost of $1 I.I 1/bbl ($0.254/gal oil equivalent) to adapt automobiles in production to use compressed natural gas
as a fuel to replace gasoline. Ammonia fuel would have simpler storage and less volume but would need a modified fuel system. This suggests a cost increment of S0.30/gal (gasoline equivalent) above the market
market price as the ammonia fuel price for automobile use.
A tax of $70 per ton of carbon emitted in energy production was recommended by the United Nations Intergovernmental Panel on Climate Change (1984). This corresponds to $0.!73/gal of gasoline used in
transportation versus zero dollars per gallon of ammonia for equivalent automobile mileage.
1
It. is assumed that by 2030 ail U.S. gasoline will be priced at a value equivalent to the 1990 real cost of imported oil.
Table 9-8. Profit to investors replacing gasoline used in U.S. automobiles with ammonia vehicle fuel
(discount rate = 11%; construction interest = 10%; ITC = 10%; APV = 0)
Gasoline NH3equiv. Gasoline Profit to
nth NH3 NH3 Total NH3 Equiv. Gasoline "real price" price incl. real cost investors using
plant total Avg. NH3 sales gasoline market pricee Gasoline with import auto plus NH3 to replace
Plant Relative investmenta PI PI prod.b pricec priced ($/gaI) replacedf impactg costsh carbon tax' gasolinej
no. cost Sum ($M) ($B) ($M) (Bgal/y) ($/gal) ($/gal) (1990 avg) (Bgal/y) ($/gaI) ($/gal) ($/gal) ($B/y)
1 1.000 1.00 957 0.96 957 0.17 0.679 1.81 0.79 0.06 1.36 2.11 1.65 -0.03
2 0.800 1.80 878 1.72 861 0.34 0.627 1.81 0.79 0.13 1.36 2.11 1.65 -0.06
3 0.800 2.60 845 2.49 829 0.51 0.605 1.67 0.79 0.19 1.36 1.97 1.65 -0.06
4 0.744 3.34 815 3.20 800 0.68 0.585 1.62 0.79 0.25 1.36 1.92 1.65 -0.07
8 0.692 6.32 770 6.05 756 1.36 0.555 1.56 0.79 0.51 1.36 1.86 1.65 -0.11
16 0.643 11.9 722 11.3 709 2.72 0.524 1.48 0.79 1.02 1.36 1.78 1.65 -0.1
32 0.598 22.2 675 21.2 622 5.44 0.493 1.40 0.79 2.04 1.36 1.70 1.65 -0.1
64 0.557 41.3 629 39.5 618 10.9 0.463 1.32 0.79 4.07 1.36 1.62 1.65 0.1
128 0.518 76.9 586 73.6 575 21.8 0.434 1.24 0.79 8.15 1.36 1.54 1.65 0.9
256 0.481 143 545 137 535 43.5 0.407 1.16 0.79 16.3 1.36 1.46 1.65 3.1
512 0.448 266 507 255 498 87.0 0.382 1.09 0.79 32.6 1.36 1.39 1.65 8.5
1024 0.416 496 472 474 463 174 0.359 1.02 0.79 65.2 1.36 1.32 1.65 21.4
1681 0.395 769 446 736 438 286 0.342 0.96 0.79 107 1.36 1.26 1.65 37.7
" The nominal plant investment (PI) for the first plantship is S975M. The PI is calculated from the cost data listed in Table 7-3 assuming discount rate 11%, construction interest 10%. The PI for the second and
third plants is 0.8 times the first plant cost. Thereafter, the plant investment decreases by the factor 0.93 for each doubling of the number produced.
' The 368-MWe OTEC NH, plantship yield of fuel-grade NH3 = 1.70 x I0! gal/y.
The sales price of ammonia is calculated using the Mossman financial analysis with ITC of 0%. There is no depreciation allowance. The price is determined by the requirement that the NPV ? 0.
'' In automobile miles/gal, 2.67 gallons NHS = 1.0 gallon gasoline, assuming the same benefit from high octane number that was found for CH^OH.
' The 1990 gasoline price = $0.786/gal (1990 avg. without taxes) (DOE/EIA, Oct. 1991, Table 9.6).
' The average U.S. gasoline supply in 1990 was 6.96 x 10" bbl/d = 107 Bgal/y (DOE/EIA, Oct. 1991, Tables 3.2a, 4). To supply ammonia fuel that would give the same total automobile mileage requires (107 x
2.67)/0.17 = 1 6 8 1 OTEC NH, plantships.
< The average import cost of crude oil (1990) was $21.78/bb! = $0.518/gal. The "real cost" of imported oil to the U.S. economy - 2.1 x market cost (National Defense Council Foundation, abstracted by Freudmann,
1988). Therefore, the real cost of imported oil was $45.7/bbl ($ 1.088/gal). The market price of gasoline was $0.786/gal (1990 avg) (DOE/EIA, Oct. 1991). Thus there was a refinery markup between oil cost and
the sales price of $(0.786 - 0.518)/gal = $0.270/gal.. The "real" price of imported oil was, then, $(0.278 + 1.088)/gal = $1.358/gal.
" A study by the Commission on Engineering and Technical Systems (1990) arrives at an added cost of $11.11/bbl ($0.254/gal oil equivalent) to adapt automobiles in production to use compressed natural gas
as a fuel to replace gasoline. Ammonia fuel would have simpler storage and less volume but would need a modified fuel system. This suggests a cost increment of $0.30/gal (gasoline equivalent) above the market
market price as the ammonia fuel price for automobile use.
1
A tax of $70 per ton of carbon emitted in energy production was recommended by the United Nations Intergovernmental Panel on Climate Change (1984). This corresponds to $0.173/gal of gasoline used in
transportation versus zero dollars per gallon of ammonia for equivalent automobile mileage.
' It is assumed that by 2030 all U.S. gasoline will be priced at a value equivalent to the 1990 real cost of imported oil.
ECONOMIC, ENVIRONMENTAL, AND SOCIAL ASPECTS 413
values with fluctuations in the world economy. The results show that national
energy decisions concerning the role of OTEC, and of other capital-intensive
energy sources, should not be based on narrow financial estimates but instead on
broad recognition of the future benefits to the nation and the world of adopting
renewable energy programs, which are inherently safe, will not degrade the
environment, and will make a major contribution to the national economy and
security.
A single OTEC plant will inject a large quantity of ocean water and discharge it at
temperature about 3.5C above or below the intake temperature. This will change
the local temperature, salinity nutrient distribution, and mixed-layer depths and
sea-surface temperatures, among others. The downstream behavior of water
discharge from an OTEC plant or plantship is essential for assessing the effects of
these disturbances.
As the plant discharge effluent enters the ocean, it will have a different density
than the surrounding water (Fig. 9-1). The behavior of the discharge plume will be
dominated by the local currents and by initial discharge momentum and buoyancy
forces resulting from the initial density difference. As distance increases from the
point of discharge, the discharge plume will be diluted by the ambient ocean water
and will sink (or rise) to reach an equilibrium level within the water column, where
the average density difference between the diluted plume and surrounding ambient
water vanishes. The plume will lose velocity until the difference between the plume
414 OCEAN THERMAL ENERGY CONVERSION
FIG. 9-1. Discharge flow field for an OTEC plant (Jirka et al., 1979).
velocity and the ambient current velocity is small. This initial region is the near-
field regime.
When the discharge effluent from the plant has reached its equilibrium depth,
it will have lost its jetlike characteristics and will have a velocity only slightly
different from the ambient current. This region is the intermediate-field regime. The
intrusion of the effluent into the stratified ocean results in the plume collapsing
vertically due to residual buoyancy forces and spreading laterally due to gravity
forces. Studies of the interaction of the spreading layer and the ambient current of
a cylindrical plant designed for radial discharge of the exhaust streams showed that
a plume will be produced in the far field that will extend up-current of the plant and
grow in width down-current of the plant due to gravity spreading until gravity forces
become small and turbulent diffusion takes over as the dominant mixing process.
The mixing process in the intermediate field is greatly reduced compared to the
near-field region. The magnitude of the ambient current dominates the behavior of
the discharge plume in the intermediate field, although local ambient density
stratification and initial near-field dilution will have some influence on the width
and thickness of the resultant plume (Jirka et al., 1979).
Further downstream, buoyancy-driven motions become small and diffusion
by means of ambient turbulence in the ocean becomes the dominant mixing and
spreading mechanism. The region of passive turbulent diffusion is the far-field
regime.
The brief description here provides a general model of the mixed-water
discharge plume from a cylindrical OTEC plant, with radial inflow of surface water
toward the intake of an OTEC plant and radial exhaust. The model is illustrated in
Figs. 9-1 and 9-2. The external near-, intermediate-, and far-field flow regions of
the OTEC plant discharge plume depend on many variables including the discharge
structure design (discharge port location, discharge angle, discharge velocity,
single or multiple discharge ports, etc.), plant size and intake and exhaust locations,
ECONOMIC, ENVIRONMENTAL, AND SOCIAL ASPECTS 415
FIG. 9-2. Surface water flow field toward an OTEC plant (Pritchard et al., 1980).
and discharge flow rate, ambient current velocity, ambient water temperature and
density, and mixed layer depth among others. Several numerical and physical
models developed by Jirka et al. (1979), Adams et al. (1979), Allender et al. (1978),
Sundaram et al. (1978), Bathen (1977), Koh and Fan (1970), Brooks (1960), and
others have been conducted to predict environmental impacts and losses in thermal
resource due to the recirculation by the interaction of the OTEC plant intake and
discharge flows with local ambient ocean currents.
The theoretical model by Jirka uses the two-dimensional continuity equation
and potential flow equation that treats the discharge as a source and ambient current
as a uniform flow. The combined flow pattern is illustrated in Fig. 9-3 with either
a stepwise or linear density stratification. The first-order solution of the model is a
rather tentative one because the model for plant interactions is extremely simple and
two dimensional.
The experimental model by Adams et al. (1979) includes <2, (evaporator intake
flow rate, ht (evaporator intake depth location below ocean surface), hj (evaporator
and condenser combined discharge depth below ocean surface), Q0 (combined
discharge flow rate), a (discharge vertical angle), Vit V0, Vc, and b0 (plant
characteristic sizes), u0 (ocean current velocity), p0 (discharge water density), p
(ambient water density), v (water kinematic viscosity), and H (depth below
surface). Some of these parameters are shown in Fig. 9-4.
Dimensionless analysis shows that several dimensionless numbers character-
ize the flow. Three such numbers are the discharge Froude number, jet Reynolds
number, and relative port size. Experiments have been done in many different cases.
416 OCEAN THERMAL ENERGY CONVERSION
FIG. 9-3. Analysis of OTEC external flow from a moored plant with radial horizontal discharge (Jirka
etal, 1979).
effects during OTEC operation may be similar. For marine biota, impingement is
expected to be confined predominantly to small fish, jellyfish, and pelagic inver-
tebrates. For near-shore OTEC plants, crustaceans are likely to be impinged in the
greatest numbers. The potential for ecologically or commercially significant losses
is small.
Marine organisms small enough to pass through the screens and be entrained
in the seawater flowing through the heat exchangers will be subjected to tempera-
ture and pressure changes in short time spans. In addition, marine life entrained in
the deep ocean water pumped up to the surface is subjected to major changes in
dissolved oxygen, turbidity, and light levels. Because of the very low level of
marine life in the deep oceans, the effects should be negligible.
Chlorine has been tested as a biocide to prevent biofouling of the evaporator
surfaces on the seawater side. Experiments in Hawaii have shown that addition of
chlorine at a concentration of 0.050 ppm 1 h/d (0.02 ppm daily average) prevents
biofouling. The U.S. EPA's standard for marine water quality allows an average
chlorine concentration of 0.01 mg/liter (0.10 ppm). Thus it appears that the impact
of OTEC biofouling control on the marine ecosystem will be minimal.
Protective hull coating materials released from ships stationed in harbors have
been found to be toxic to resident organisms. The toxic substances released from
the coatings can accumulate in the tissues of biofouling organisms, and be passed
up the food chain. There is no evidence that such coatings would be necessary for
commercial OTEC installations.
If OTEC assumes its full potential to provide world energy, eventually OTEC plants
will be deployed to generate about two-tenths of a megawatt per square kilometer
of ocean surface; that is 200-MWe plants will be sited about 30 km apart, either
grazing on the tropical oceans or grouped near a large shore installation, such as in
the Gulf of Mexico. The latter type of deployment might minimize undersea power
transmission and shore-based power conditioning costs by allowing a single shore
facility to draw power from many OTEC plants.
0.05C and a warming in the water column above the cold-water intake of 0.8C.
The mean temperature profile in the Gulf of Mexico after 10 years of operation with
one thousand 200-MW OTEC plants is shown in Fig. 9-5. These calculations are
based on the utilization of 8.5 m3 of total seawater pumped per second per megawatt
of power produced (8.5 m3/s is a high number; about 5 m3/s would be typical). The
calculated rate of warming of the deep water resulted from the fact that the model
(Martin and Roberts, 1977) does not allow for the removal of this heat input to the
deep water from the Gulf by the currents.
The effluent from one OTEC plant could reduce the thermal resource available
to other plants within a power park either by directly entering the warm-water intake
of a plant down stream or by effectively thinning the mixed layer down stream. This
thinning would increase the likelihood that cooler water near the bottom of the
mixed layer would be drawn up into the intake of neighboring plants.
Jirka et al. (1977) have presented a preliminary analysis that can be used for
estimating minimum plant spacing that will prevent the effluent from one plant
from degrading the effective thermal resources available to neighboring plants. In
his analysis, Jirka assumes both a mixed-discharge mode and a two-layer ambient
ocean. After initial dilution due to jet entrainment the mixed-discharge effluent is
assumed to form a layer of intermediate density between the upper and lower layers
of the ambient ocean. The effluent then drifts with the ambient current and spreads
laterally, due to buoyancy. Thus, the intermediate layer reduces the effective
thickness of the mixed layer at neighboring plant sites and increases the potential
for recirculation.
For a row of plants oriented orthogonal to the dominant current and an ambient
mixed-layer depth of 700 m, a minimum lateral spacing of 4.8 km is predicted for
FIG. 9-5. Mean temperature profile in the Gulf of Mexico after 10 years ot'opcration of 1000 200-MWe
OTEC plants (Martin and Roberts, 1977).
422 OCEAN THERMAL ENERGY CONVERSION
100-MW plants and 36 km for 400-MW plants. In the case of a rectangular grid of
plants, the minimum spacing depends on the ambient mixed-layer depth, the
magnitude of the ambient current, and the number of rows in the grid. In the case
of a mixed-layer depth of 70 m, an ambient current of 0.1 m/s, and a configuration
of five rows, a minimum spacing of 5.6 km is predicted for 100-MW plants and 160
km for 400-MW plants. Extremely simple and roughly approximate, Jirka's one-
dimensional interaction model is surpassed by his later two-dimensional model. In
the latter, Jirka (1978) deals directly with the problem of a source of buoyancy in
a current. His modified results suggest that lateral spacing requirements may not be
driven solely by thermal resource considerations. In addition, assessments of
downstream environmental impacts may provide constraints on plant spacing.
the plant. Other plants will both be subject to this influence and also add their
incremental effect.
9.2.8 Circulation
A medium-size OTEC plant of 100-MW capacity and a temperature differential of
23.3C (42F) would require an intake of 300 to 500 m3/s of warm surface water and
an equal intake of cold deep water. The local withdrawal of the 300 m3/s from the
surface layer would induce a radial inflow toward this sink in a pattern dependent
on surface currents. At a distance of 1 km from the intake, assuming that the flow
is drawn from a layer 40 m thick, the in-flowing velocity would be about 0.12 cm/
s (0.05 in./s). However, a vortex flow pattern might develop as a result of the local
sinking of surface water, as shown in Fig. 9-2. The induced circulation could
possibly result from friction, mixing convective acceleration, Coriolis forces, as
well as other terms. Pritchard et al. (1980) presents a surface water vortex flow
pattern of near-field OTEC circulation for a cylindrical spar OTEC design. At any
latitude other than the equator, Coriolis effects will cause the inflow to turn and
approach the OTEC sink as a spiral. Pressure drop associated with this withdrawal
of surface water would cause a slight depression in sea level above the plant and a
rise in the isotherms in the upper part of the thermocline. The horizontal pressure
field resulting from this rearrangement of the density field would support a
geostrophically balanced, cyclonic flow characteristic of a cold core eddy. The
first-order models (DOE, 1980) of an OTEC vortex suggest that a 100-MW plant
drawing warm water from a mixed layer 100 m deep would produce an eddy with
a radius of 10 to 20 km, having a maximum tangential velocity of about 15 cm/s at
a distance of about 1.5 km from the sink. The thermocline below the sink would be
raised about 15m. Pritchard's simple two-layered model assumes that the bottom
layer is infinitely deep and motionless, is constructed from a frictionless outer
region, and has a solid body motion core. Similar models have been used to study
the circulation flow in a hurricane. Such a distortion of the thermal field and the rise
in the thermocline could, in fact, reduce the temperature of the surface water
available as a heat source to the OTEC plant. However, calculations (Roels, 1980)
suggest that the warm surface water temperature drop due to the circulation is
insignificant for a 100-MW plant operating on a surface mixed layer 100 m deep.
If the inter-plant space is sufficiently large, this temperature reduction is insig-
nificant.
The interaction of the OTEC vortex with island coastal circulation should be
specifically explored, since the first commercial OTEC plants may be located near
islands. Thermal structures in coastal boundary layers are subject to natural
transients related to wind-induced upwelling and downwelling. It is difficult to
forecast the possible interaction without long-term observational data and numeri-
cal modeling. Currently, there is a lack of studies relating the possible structure and
intensity of the expected OTEC vortex as a function of plant size and ambient
oceanic conditions.
424 OCEAN THERMAL ENERGY CONVERSION
of 5 ,ug N03/liter per day is therefore added to the surface water locally at the Peru
coast. Thus, the nutrient increase from upwelling of an OTEC power park with 100-
MW plants and area density of a 120-km2 area per plant would be equal to that of
an equivalent area of the ocean off Peru, which is the world's most productive
coastal upwelling region.
The discharge and hence nutrient input of OTEC plants may be confined,
however, to depths below the euphotic zone. For OTEC plants to be efficient, the
temperature gradient between surface and deep water has to be maximally utilized.
Therefore, the mixed discharge must not be recirculated into the plant surface
intake, as a decrease of 1C in the temperature difference would reduce the
efficiency of the plant by 10%. For this reason, OTEC design has plants with
combined discharge that will sink to an equilibrium depth below 150 m. Because
the depth of the mixed layer in a typical tropical ocean is less than 100 m, nutrient
enrichment of the euphotic zone, where plankton photosynthesis takes place, by
OTEC discharge would be limited to vertical diffusion about 104 m2/s in the
immediate vicinity of the plant. The nutrient enhancement near the plant is certainly
much less than estimated previously in the surface discharge scenario. At some
distance from the OTEC plant, however, an uplifting of density surfaces and of the
concentration gradient of plant nutrients may occur. Increased nutrient input to the
euphotic zone may take place in this far-field zone, stimulating the growth of the
plankton. It is not yet known if large-scale OTEC operations will result in a gain of
surface plankton, but clearly plankton populations will be displaced in the vicinity
of the plant. One could expect a trail of organisms in the wake of discharged
upwelling water, as shown in Fig. 9-6 (Miller, 1977). In the order of their
appearance one could expect the algae or phytoplankton, followed by the herbi-
vores, and then the primary, secondary, and tertiary carnivores. Possibly this food-
chain effect could be put to advantage by judicious planning and study leading
eventually to harvesting. In any case, the "plowing" of the sea should prove to be
beneficial to the natural environment whether the end products are harvested or not.
Lack of funding has prevented study of the ecological effects of grazing OTEC
plantships. A quantitative picture was provided by Miller (1977) in the original
studies of grazing OTEC plantships.
FIG. 9-6. Probable food-chain distribution in wake of moving OTEC ship (Miller, 1977).
water in the coastal zones is continually supplied with fresh nutrients in the runoff
from the adjacent land and, hence, supports a high level of plant life activity and
produces 54% of the fish. Only 0.1 % of the ocean area lies in the upwelling regions,
where nutrient-laden water is brought up from the ocean depths, yet these regions
produce 44% of the fish. The reason for this spectacular difference can be seen in
Table 9-9, which shows that the nitrate and phosphorus concentrations in deep
seawater are about 150 and 5 times more, respectively, than their counterpart
concentrations in surface water at a typical site (St. Croix in the Virgin Islands).
Proposals to produce artificial upwelling, including one using nuclear power,
have concluded that the cost would be excessive. Roels (1980) studied the
possibility of using a shore-based OTEC plant to supply nutrient-laden water to a
mariculture system, with a series of experiments carried out at St. Croix in the U.S.
Virgin Islands. At that site the ocean is 1000 m deep only 1.6 km offshore. Three
ECONOMIC, ENVIRONMENTAL, AND SOCIAL ASPECTS 427
ing raising fish, seaweed, abalone, and lobster in Hawaii. Daniel (1989) reported
that a total of eight deep seawater systems have been installed and operating since
1987 at the Natural Energy Laboratory of Hawaii, Ocean Farms, Hawaii, and
Hawaii Ocean Science and Technology Park. These pipes have provided the cold
seawater to grow abalone, salmon, steelhead trout, flounder, and several commer-
cially valuable seaweeds successfully.
The world reserves of oil may be sufficient to maintain the current consump-
tion rate for more than several decades. The political disposition of the oil-exporting
nations, however, may limit the available supplies. In the United States (including
Alaska), oil production has declined following a peak in 1979. U.S. oil production
in that year reached 11 million barrels per day, but has declined in recent years to
9 million barrels per day in 1990. The U.S. dependence on oil net imports is given
in Fig. 9-8. The energy trade balances of the United States have been negative in
recent years and are the major contributing factor in the national annual trade
deficit. In order to improve the U.S. economy, a reduction in energy imports is
obviously needed.
Another energy transition may be on the horizon. Alternative energy sources
such as OTEC and/or increased efficiency in the use of energy will be needed if the
production of oil in the world continues to decline. Even if the world's oil
production does not decline, additional alternative energy input should be provided
to meet environmental requirements for the world's growing population and to
improve human living standards.
High oil prices have affected developing countries more severely than the
industrialized nations. Developing countries account for 15% of the world's energy
consumption. Sixty percent of this energy is supplied by oil, and 30% of the oil is
imported. In the case of Jamaica, the oil import cost increased from 17% of the
country's budget in 1973 to 60% in 1983. Similarly, as a fraction of the cost of total
imports, the oil bill increased from 10% to 34% in 1983. The Jamaican economy,
and the economies of numerous other developing nations, have stagnated as a result
of the high cost of oil imports.
Facing the large national deficit partly due to oil import cost, the United States
has a different energy challenge today from that in the 1970s. We can predict how
long easily recoverable oil reserves will last at present rates of consumption. The
opportunity to develop energy alternatives for oil is greater than ever because of
modern technology. OTEC is certainly one of the most promising alternative
energy source candidates. As explained in previous chapters, this resource is more
than enough to provide for current U.S. energy consumption and expected demands
well into the future. The extra electricity generated by OTEC stored as energy-
intensive products, particularly vehicle fuels to replace gasoline and diesel oil, can
be exported to provide substantial future energy supplies for the world, as well as
export merchandise values for the United States. As discussed in Chapters 7 and 8,
the use of OTEC in combination with water electrolysis to produce liquid fuels that
would reduce U.S. oil imports is economically attractive. The financial analyses
show that costs of OTEC energy in the form of liquid delivered to U.S. users, if rapid
commercial development was supported, could be low enough to compete with oil
after the year 2000. With a production rate compatible with reasonable U.S. funding
and shipbuilding capabilities, OTEC methanol plantships could be delivering
enough motor vehicle fuel by 2025 to eliminate the need for imported fuel to supply
gasoline in the United States. Alternatively, ammonia plantships could supply
nonpolluting fuel (no carbon emissions) to eliminate all U.S. need for gasoline by
mid-century. Large benefits would result for U.S. employment, industrial produc-
tivity, and balance of trade.
The reductions of oil cost and consumption in recent years were made possible
by impressive gains in energy efficiency around the world, the development of
alternative energy sources, and the political situation in Mideast oil export coun-
tries. However, the current oil price is not stable. While the OPEC members are
husbanding their oil reserves in an effort to maintain prices, non-OPEC producers
such as the United States, the United Kingdom, and the Soviet Union are depleting
their reserves at a rapid pace. The Middle East currently contains nearly 60% of the
world's proven oil reserves. When non-OPEC petroleum production declines in the
1990s, Middle Eastern OPEC members may gain a major role in managing world
oil supplies. World energy prices could again become subject to their control.
The drop of oil prices in recent years has undermined investments in energy
alternatives. Declining energy prices have already led many countries to cut
successful energy programs that would have provided substitutes for oil in the
beginning of the next century. OTEC is a typical example. There has been little
research and development activity in the past several years. OTEC is increasingly
attractive because it can shield the economy from the effects of increasing oil import
prices. Commercial development of OTEC can make it competitive with conven-
tional fossil fuel and nuclear plants. As shown in Chapters 7 and 8, this objective
can be achieved early in the next century if the latter sources take the steps needed
to comply with environmental and safety requirements.
432 OCEAN THERMAL ENERGY CONVERSION
The contemporary world consists mainly of food-deficient countries, with over 100
of them importing grains from the United States alone. Most of the national food
deficits are the results of excessive population growth, land degradation, other
factors, or combination of these. In recent years, grain deficits have worsened in
Africa and the Middle East. Over the past decade, growth in food output has slowed
markedly. The slowdown in food output dates from the first oil price increase.
Between 1950 and 1973, grain production increased at 3.1 % per year, outstripping
population growth. During the years since, production has expanded at only 2.2%
per year, dramatically narrowing the margin between the growth in food production
and that of population. Per capita production has declined from 1.2 to 0.4. More than
500 million people now suffer from food and protein deficiency. The need for more
and more food production, particularly high-quality protein, is great. Developed
nations have achieved high agricultural productivity using petroleum-dependent
machinery and fertilizers. Another factor limiting the expansion and agricultural
production is the scarcity of arable land. Most of the arable land in the world is in
use, and although some arid areas can be made suitable for cultivation through
irrigation, fresh water needed to do so is scarce. Increasing the water supply would
require large capital investments and vast amounts of energy.
Because of the limited supply and high costs of arable land, fresh water, and
petroleum, it is essential that we explore alternative methods to provide the world's
people with new sources of fresh water, energy, and food. The scarcity of arable
land necessary to increase food production naturally points to the vast area of the
oceans that cover approximately 70% of the earth's surface. Currently, the sea
produces only about 5-10% of the protein consumed in the world. Throughout most
of history, the human demand for seafood did not even remotely approach the
sustainable yield of oceanic fisheries, but as world population has nearly doubled
since mid-century, claims on many fisheries have become excessive. From 1950 to
1970, the world fish catch expanded at 5% per year, as fast as or even faster than
the global economy growth. This changed abruptly after 1970, when the annual
growth rate dropped to 1 %. Overfishing, which had been the exception, became the
rule, depleting the natural stocks. Fish catch per person, including fisheries from
fish farming, has been down 15% since 1970. The biggest reductions in fish
consumption have been in the third world countries such as the Philippines.
The promise of OTEC to become an important resource for mariculture and
food production through use of the OTEC cold water has been discussed in Section
9.2. The potential protein production of the oceans exceeds that of land-based
agricultural systems and is not dependent on petroleum for fertilizer and energy
required by advanced agricultural technology. The projected protein yields of 27.8
tons per hectare per year exceed by far the protein yields of alfalfa at 0.71 ton per
hectare per year. Alfalfa is land-based agriculture's highest protein-producing crop,
ECONOMIC, ENVIRONMENTAL, AND SOCIAL ASPECTS 433
Table 9-10. Annual gross dollar value of production from a combined OTEC-mariculture
system using the same deep-water flow rate of 3.76 m3V/s
System Product Unit price Gross sales value
OTEC 1 MW 60/kWh $ 473,000
Mariculture Shellfish $2.2/kg meat $1,564,200
I693t ($l/lb meat)
From Rods (1980).
434 OCEAN THERMAL ENERGY CONVERSION
oceanic islands rise steeply from the ocean floor and have steep offshore slopes.
Therefore these islands in the tropical ocean are the most likely locations for
economic land-based OTEC plant sites.
Tropical islands, which need electric baseload power and/or fresh-water
supply, constitute excellent early markets for OTEC power plants. Worldwide
there are 98 nations and territories with the prerequisites necessary to use land-
based or near-shore OTEC technology. Of these, 53 candidates are islands in
tropical areas (United Nations, 1984).
Many such islands share the following general characteristics: (1) heavy
dependence on imported oil for electric power generation and shortage of natural
precipitation for fresh-water supply, (2) high electricity costs due to small demand
and high transportation costs, (3) small incremental power needs with baseload
capacity addition in the 5- to 40-MWe range, (4) few domestic alternative energy
resources, and (5) a developing economy with a growing population. Small-scale
shelf-mounted OTEC plants are marginally economic, if the current state of the art,
expected oil prices, and the environmental and social difficulties encountered by
coal and nuclear power are considered.
It is estimated (Avery and Dugger, 1980; Gopalkrishman, 1984; Toms and
Ford, 1984) that if OTEC supplied 10% of the potential tropical islands' OTEC
market, 300 plants producing, in total, 57,700 MW of electric power (Bell, 1980;
Sanchez, 1980; Pinckert, 1980) would be needed.
Coupling an OTEC plant to a mariculture operation of island-based plants is
under active development in Hawaii and has been planned in Tahiti. Suitable sites
with deep water close to shore are widely available at volcanic islands. Since the
energy demands are in the range of 5 -25 MW, a relatively high cost per kilowatt
hour of OTEC power generation is implied. Roels (1980) estimated that the gross
sales value of the seafood produced by a combined OTEC-mariculture system
using a deep-water flow rate of 3.75 m3/s would run about five times the value of
the electricity produced by an OTEC 1 -MWe plant with the same flow rate. A small
land-based OTEC plant in Hawaii has been designed to supply deep nutrient-rich
seawater to an aquaculture facility to produce a net electric power output of 300
kWe (Johnson, 1989).
The combination of aquaculture with a small-scale OTEC plant can signifi-
cantly affect the economics of OTEC operation. Aquaculture can support the costs
of installing a cold-water pipe and its associated seawater pumps. The OTEC plant
can be viewed as just the warm-water pipe, heat exchangers, and power generation
equipment. The composite plant appears to be commercially feasible. The design
(Johnson, 1989) provides a deep ocean water rate of 13,000 gallons per minute for
aquaculture and an electric power of 300 kW into a local electricity supply grid. In
addition, the plant would produce a potable water rate of 2650 gallons per day.
OTEC processes that employ the flash evaporation of seawater are capable of
producing fresh water as a byproduct of power production. In many island locations
fresh water has a market value of $1-11 (1985 value) per 3875 liters (1000 gallons)
(SERI, 1985). The price for island-based OTEC power could become competitive
with fossil-produced power when water is also produced and sold at these prices.
ECONOMIC, ENVIRONMENTAL, AND SOCIAL ASPECTS 435
Even when electrical power is not desired, OTEC appears attractive for the
production of high-priced fresh water alone. Either open- or closed-cycle OTEC
can be used.
It has been estimated (Johnson, 1989) that the cost of fresh water produced by
OTEC at a favorable island site may be one-third that of fresh water produced by
the standard multistage flash-evaporation process using fossil energy as a heat
source. The technical feasibility of using ocean energy to desalinate seawater has
been demonstrated successfully by an open-cycle heat and mass transfer test
apparatus that produces 22 liters per second of potable water having a salinity of 86
ppm(Trenka, 1988).
Another marketable OTEC application in the islands involves hotel-resort
developments. When cost analyses are performed factoring in not only fresh-water
production but also space cooling and refrigeration via utilization of the cold
seawater into the electrical energy product costs, the overall system economics
improve dramatically.
In conclusion, the reduction in dependence on imported oil and the related
benefits of OTEC could greatly improve the economic stability of many tropical
islands. OTEC-produced metals (aluminum, magnesium, nickel, etc.) (Homma et
al., 1979; Kajikawa and Hiramatsu, 1986) as well as other inorganic and organic
chemical plants could be located on these islands. The deep seawater would
enhance the local island fisheries and provide air conditioning and refrigeration.
The potential industrial factories would create job opportunities and promote local
economic growth.
decrease or perhaps eliminate our deficit; it will help to stabilize the energy cost and
fulfill the policy goal of energy independence; it will stimulate OTEC-related
industries and generate thousands of additional jobs; it will also improve the air
pollution and abate the greenhouse effect. Because of these environmental, eco-
nomic, and socially attractive aspects, OTEC is one of the most promising solutions
to the problems of supplying future needs for reliable, economic, and environmen-
tally benign energy for the twentieth century and beyond.
REFERENCES
Adams, E. E., D. J. Fry, andD. H. Coxe, 1979. "Results of a near-field physical model study."
Proc. 6th OTEC Conf., Washington, D.C.
Allender, J. H., R. W. Blevins, G. L. Dugger, and E. J. Francis, 1978. "OTEC physical and
climatic environmental impacts: An overview of modeling efforts and needs." Proc. 5th
Ocean Thermal Energy Conversion Conf., Miami Beach, Fla., Sept.
Avery, W. H., 1988. "A role for ammonia in the hydrogen economy." Int. J. Hydrogen
Energy 13, 761.
, R. W. Blevins, G. L. Dugger, and E. J. Francis, 1976. Maritime and construction
aspects ofOTECplantships. Johns Hopkins Univ. Applied Physics Lab., SR76-1B.
, and G. L. Dugger, 1980. "Contribution of OTEC to world energy needs." Int. J.
Ambient Energy, 1(3), 177.
, D. Richards, and G. L. Dugger, 1985. "Hydrogen generation by OTEC electrolysis,
and economical energy transfer to world markets via ammonia and methanol." Int. J.
Hydrogen Energy 10, 727.
Bathen, K. H., 1977. "A further evaluation of the oceanographic conditions found off
Keahole Point, Hawaii, and the environmental impact of near-shore OTEC plants on
subtropical Hawaiian waters." Proc. 4th Annual Conf. on Ocean Thermal Energy
Conversion, New Orleans, La., July, IV-79.
Bell, R. E., 1980. "An island utility looks at OTEC." Proc. 7th Ocean Energy Conf.,
Washington, D.C, June, II, 8.1.
Blumberg, A. P., and G. L. Mellor, 1979. "A whole basin model of the Gulf of Mexico." Proc.
6th OTEC Conf., Washington, D.C., June II, 13.15.
Brooks, N. H., 1960. Diffusion of sewage effluent in an ocean current. California Inst.
Technology. Research report, Pasadena, Cal.
Brown, L. R., 1986. State of the World 1986. New York: W. W. Norton.
, 1989. State of the World 1989. New York: W. W. Norton.
Commission on Engineering and Technical Systems, 1990. Fuels to drive our future.
National Academy Press, 0-309-04142-2, April.
Daniel, T., 1983. Annual Report 1983. Natural Energy Laboratory of Hawaii.
, 1989. New seawater delivery systems at the Natural Energy Laboratory of Hawaii.
ASME. Natural Energy Laboratory of Hawaii, Kailua-Kona, Hawaii, 323.
-, 1990. Activities at the Natural Energy Laboratory of'Hawaii/HOST. Natural Labora-
tory of Hawaii Authority, Keahole Point, Hawaii.
Ditmars, J. D., and R. A. Paddock, 1979. "OTEC physical and climatic environmental
impacts." Proc. 6th OTEC Conf., Washington, D.C., 6a-3/l.
DOE, 1980. DOE workshop on the potential environmental consequences of OTEC plants,
DOE Conf-800154, Upton, N.Y., Jan.
DOE/E1A, 1990. Monthly energy review. U.S. Department of Energy, Washington, D.C.,
Tables 3.la,b, 3.4.
ECONOMIC, ENVIRONMENTAL, AND SOCIAL ASPECTS 439
DOE/EIA, 1991. Monthly energy review. U.S. Department of Energy, Washington, D.C.
Energy Information Agency, 1989. Monthly energy review.
Francis, E. J., 1977. Investment in commercial development of OTEC plantships. Johns
Hopkins Univ. Applied Physics Lab., Internal report, Dec.
Freudman, A., 1988. "Cost of foreign crude? '2.1 times the nominal price'." Energy Daily,
16(184), 1.
Gauthier, M. M., 1985. OTECThe French pro gram, a pilot electric power plant for French
Polynesia. IFREMER Report, March.
Gopalakrishman,C., 1984. The emerging marine economy of the Pacific. Boston: Butterworth.
Hileman, B., 1984. "Recent reports on the greenhouse effect." Environmental Science and
Technology, February, 18(2), 45.
Homma, T., and H. Kamogawa, 1978. "Conceptual design and economic evaluation on
OTEC power plants in Japan." Proc. 5th Ocean Thermal Energy Conversion Conf.,
Miami Beach, Fla., Feb., 1, V-91.
, N. Kamogawa, and S. Nakasaki, 1979. "Design consideration on 100 commercial
scale OTEC power plants and a 1 MWe class engineering test plant." Proc. 6th OTEC
Conf., Washington, D.C., June, 1, 5.7.
Jirka, C. H., 1978. Preliminary guideline for the siting of multiple OTEC plants. Cornell
Univ. Dept. of Environ. Eng., Ithaca, N.Y., June.
, F. A. Johnson, D. J. Fry, and R. D. Harleman, 1977. OTEC plant experimental and
analytical study of mixing and recirculation. Massachusetts Institute of Technology, R.
M. Parsons Laboratory, MIT Report No. 231.
J. H. Jones, and P. E. Sargen, 1979. "Modeling of the intermediate field OTEC
discharges." Proc. 6th OTEC Conf., Washington, D.C., June, 1, 13.14.
Johnson, F. A., 1989. "Small land based OTEC plant." Proc. of the EEZ Resources:
Technology Assessment Conf., Honolulu, Jan., 6.20.
Jones, Jr., M. S., K. Sathyanarayana, A. L. Markel, and J. E. Snyder III, 1979. "Integration
issues of OTEC technology to the American aluminum industry." Proc. 6th OTEC
Conf., Washington, D.C., June, 1, 10.9.
, K. Sathyanarayana, V. Thiagarajan, J. E. Snyder, A. M. Sprouse, and D. Leshaw.
"Aluminum industry applications for OTEC." Proc. 7th Ocean Energy Conf., 8.5-1.
Koh, C. Y., and L. N. Fan, 1970. Mathematical models for the prediction of temperature
distributions resulting from the discharge of heated water into large bodies of water.
U.S. EPA Water Pollution Control Research Series 16130 DWO, Oct.
Kajikawa, T., and H. Hiramatsu, 1986. "Status and prospects of OTEC research and
development in Japan." Proc. 13th OTEC Congress of the World Energy Conf., Oct.
(Exp. Mtg. #3), 1.
Krenz, J. H., 1984. Energy Conversion and Utilization. Second Ed. Boston: Allyn and
Bacon.
Lavi, A., and G. H. Lavi, 1979. "OTEC: Social and environmental issues." J. Energy 4,833.
Lockheed Missiles and Space Co., Inc., 1975. OTEC power plant technical and economical
feasibility. Lockheed Missiles and Space Co., April.
Martin, P. J., and G. O. Roberts, 1977. "An estimate of the impact of OTEC operations on
the vertical distribution of heat in the Gulf of Mexico." Proc. 4th Annual Conf. on Ocean
Thermal Energy Conversion, New Orleans, La., March, IV, 26.
Mayer, J., 1976. "The dimensions of human hunger" Scientific American, 253, 40.
Miller, A. R., 1977. Ranges and extremes of the natural environments related to the design
criteria for OTEC. Woods Hole Occanographic Institution Report WH01-77-61,
Oct.
440 OCEAN THERMAL ENERGY CONVERSION
Othmer, D. F., and O. A. Roels 1973. "Power, fresh water and food from cold, deep-sea
water." Science 182, 121.
Pinckert, W. F., 1980. "Overview of OTEC potential for electric power generation in Guam,
Micronesia and the Western Pacific." Proc. 7th Ocean Energy Conf., Washington, D.C.,
June, IIc/3-1.
Pont, R. J., 1978. "Effect of changes in the relative costs of fuel and capital resources on
OTEC's economic competitiveness." Proc. 5th Ocean Thermal Energy Conversion
Conf., Miami Beach, February, II 4458.
Pritchard, D. W, J. Blanton, G. Canaday, J. Ditmars, T. Hopkins, G. Marz, G. L. Mellor, D.
Pillsbury, and D. P. Wang, 1978. "Physical consequences of OTEC." Workshop on
Potential Environmental Consequences of OTEC, Upton, N.Y., Jan.
, 1980. "The physical consequence of OTEC." Potential Environmental Consequence
of OTEC Plants Workshop, Upton, N.Y., Jan.
Quinby-Hunt, M. S., S. D. Sloan, and P. Wilde, 1987. "Potential environment impacts of
closed-cycle OTEC." Environ. Impact Access Rev., 7, 169.
, P. Wilde, and A. T. Dengler, 1986. "Potential environment impact of open-cycle
OTEC." Environ. Impact Access Rev., 6, 7.
Roels, O. A., 1975. "The economic contribution of artificial up-welling mariculture to sea-
thermal power generation." Proc. 3rd Workshop on Ocean Thermal Energy Conver-
sion, Houston, Tex., May, 128.
, 1980. "From the deep sea: food, energy, and fresh water." J Mechanical Engineering
102, 37.
Rosen, S. J., 1979. "OTEC: A solution to the problem of energy versus the environment."
Proc. 6th OTEC Conf., Washington, D.C., 4D-5/1.
Sanchez, J. A., 1980. "The OTEC alternative for Puerto Rico versus coal-oil-nuclear." Proc.
7th Ocean Energy Conf., Washington, D.C., June, II, 8.2.
SERI, 1985. Thermoeconomic optimization of OC-OTEC electricity and water production
plants. Solar Energy Research Institute Report SERI/STR-251-2603 DE85121299,
May.
Sullivan, S. M., M. D. Sands, J. R. Donat, P. Jetsen, M. Smooker, and J. F. Villa, 1981.
Environmental assessment OTEC pilot plants. Lawrence Berkeley Lab., Research
report LBL-12328.
Sundaram, T. R., S. K. Kapur, and A. M. Sinnarwalla, 1978. Some further experimental
results on the external flow field of an OTEC plant. Hydronautics, Inc. Tech. report
7621-2, Laurel, Md.
Thompson, J. D., H. E. Hurlburt, and P. J. Martin, 1978. "Results from the Gulf of Mexico
OTEC far-field numerical model." Proc. 5th Ocean Thermal Energy Conversion Conf.,
Miami Beach, Fla., 1, III-414, Feb.
Toms, A., and G. Ford, 1984. OTEC for island applications. Institute of Electrical Engineers,
Energy Options No. 233, 220.
Trenka, A. R., 1988. Research done by Creare R&D, Inc., under contract with SERI. Solar
Energy Research Institute, Oct.
, L. J. Rogers, R. J. Hays, and L. A. Vega, 1989. "A status assessment of OTEC
economics." Resources Technology Assessment Conf., Honolulu, HI, Jan. 6.32.
United Nations, 1984. A guide to OTEC for developing countries. United Nations, N.Y.,
United Nations report.
Walsh, J. J., 1975. "A spatial simulation model of the Peru upwelling ecosystem." Deep Sea
Research 22, 201.
Williams, R. II., 1975. "The greenhouse effect and ocean-based solar energy systems."
Center for Environmental Studies, Princeton University, Oct. Working paper No. 21.
INDEX