Things You Should Know.......................................... 2 Wireless Repeater Assignment.............................. 14
About This Programming Guide ............................................... 2
Conventions.............................................................................. 2 Wireless Siren Assignment .................................... 14
Installer Code (Default: 0000 / 000000).................................... 2
Wireless Programmable Output (PGM) Settings .. 14
Maintenance Code (Default: 1111 / 111111)............................ 2
Master Code (Default: 1234 / 123456) ..................................... 2 Wireless PGM Timer............................................... 15
Entering Programming Mode.................................... 2 Wireless Supervision Options................................ 15
Single Digit Data Entry Method ................................................ 2
Feature Select Programming Method....................................... 3 Wireless Repeater Options..................................... 17
Decimal and Hexadecimal Values ............................................ 3
Appendix 1: PGM Event Table................................ 19
Installer Quick Keys................................................... 3
Appendix 2: Specifications..................................... 22
Zone Programming .................................................... 4
Appendix 3: Connection Diagrams........................ 22
Remote Control Button Programming ..................... 5 Power Connections ........................................................... 22
Telephone Line Connections ............................................ 24
System Timers............................................................ 6 PGM Connections ............................................................. 25
Hardwire Zone Connections.............................................. 26
On-board Programmable Outputs (PGMs) .......... 6 Connecting the Radio Antenna (MG6160 only) ................ 26
Connecting to a UIP256 .................................................... 27
System Options.......................................................... 7 X10 Transmitter Connections (MG6160 only) ................... 27
Connecting Magellan to WinLoad ..................................... 28
Communicator Settings ..................................... 10 Connecting a Paradox Memory Key (PMC5) .................... 28
Tabletop Mounting ............................................................ 29
Report Codes............................................................ 11 Mounting Magellan on the Wall......................................... 29
System Settings ....................................................... 13 Appendix 4: Ademco Contact ID Report Codes ... 30
Wireless Transmitter Assignment .......................... 13 Appendix 5: Automatic Report Code List ............. 32
Wireless Output Assignment .................................. 14
Wireless Keypad Assignment................................. 14
Things You Should Know
About This Programming Guide
This programming guide should be used in conjunction with the Magellan Reference & Installation Manual which can be downloaded
from our website at paradox.com. Use this guide to record the settings programmed for this console.
Conventions
This symbol designates a feature that can also be programmed in the Installer menu which can be accessed by pressing
[menu] and then entering your [INSTALLER CODE]. The icon will then be followed by the path or buttons that have to be
pressed in order to access the feature once in the Installer menu. For example:
J[4] J[6] = Once in the Installer menu, press the [4] key and then press the [6] key to access the desired feature.
Refer to the Installer Menu Overview on the back cover for more information on accessing and using the Installer menu.
2 Programming Guide
Feature Select Programming Method
After entering certain sections, eight options will be displayed where each option from [1] to [8] represents a specific feature. Press
the key corresponding to the desired option and the option number will appear in the LCD screen. This means the option is ON.
Press the key again to remove the digit from the LCD screen (a * appears), thereby, turning OFF the option. Press the [*] key to set
all eight options to OFF. When the options are set, press the [#] key to save and advance to the next section.
Decimal and
Hexadecimal
Values:
Keys [0] to [9] = 0
to 9
Magellan 3
Zone Programming
Zone Definitions ( J[4] J[6] ) Zone Options
000 = Zone Disabled (default) 008 = Delayed Fire Zone [1] = Auto-zone Shutdown (default) [6] = Intellizone
001 = Entry Delay 1 009 = 24Hr. Burglary Zone [2] = Bypassable Zone (default) [7] = Delay alarm transmission
002 = Entry Delay 2 010 = 24Hr. Hold-up Zone [3] = Future Use [8] = Force Zone (default)
003 = Follow Zone 011 = 24Hr. Buzzer Zone [4] [5] Zone Alarm Type
004 = Follow / Stay Zone 012 = 24Hr. Gas Zone OFF OFF Audible alarm (default)
005 = Instant Zone 013 = 24Hr. Heat Zone Intellizone is not for use in UL
OFF ON Pulsed alarm installations.
006 = Instant / Stay Zone 014 = 24Hr. Water Zone
007 = Instant Fire Zone 015 = 24Hr. Freeze Zone ON OFF Silent alarm Force Arming is not permitted in UL
ON ON Report only installations.
4 Programming Guide
Remote Control Button Programming
Section RC# Data (Default: 4DE0) Section RC# Data (Default: 4DE0)
+ +
+ +
[041] 1 ______ ______ ______ ______ [049] 9 ______ ______ ______ ______
[042] 2 ______ ______ ______ ______ [050] 10 ______ ______ ______ ______
[043] 3 ______ ______ ______ ______ [051] 11 ______ ______ ______ ______
[044] 4 ______ ______ ______ ______ [052] 12 ______ ______ ______ ______
[045] 5 ______ ______ ______ ______ [053] 13 ______ ______ ______ ______
[046] 6 ______ ______ ______ ______ [054] 14 ______ ______ ______ ______
[047] 7 ______ ______ ______ ______ [055] 15 ______ ______ ______ ______
[048] 8 ______ ______ ______ ______ [056] 16 ______ ______ ______ ______
The button of the REM1 and REM2 remote controls has been permanently programmed to disarm the system. The buttons
functionality cannot be altered. The button of the REM2 remote control has been permanently programmed to request feedback from
the system. The buttons functionality cannot be altered.
When section [040] is accessed, the console will display the contents of section [041] and copy the saved value of that section to all remote
options: [041] to [056].
Magellan 5
System Timers
Section Data (value from 000 to 255) Description Defaults
[060] ____/____/____ seconds Entry delay 1 ( J[4] J[4] ) 045 secs.
[061] ____/____/____ seconds Entry delay 2 ( J[4] J[4] ) 045 secs.
[062] ____/____/____ seconds Exit delay ( J[4] J[4] ) 060 secs.
[063] ____/____/____ minutes Bell cut-off time ( J[4] J[4] )* 004 mins.
[064] ____/____/____ x 15 minutes No movement time Disabled
[065] ____/____/____ seconds (minimum 10 seconds) Intellizone delay 045 secs.
[066] ____/____/____ seconds Recent closing delay Disabled
[067] ____/____/____ times Auto-zone shutdown 005 times
[068] ____/____/____ seconds PGM1 timer Disabled
[069] ____/____/____ seconds PGM2 timer Disabled
[070] ____/____/____ minutes Power failure report delay 015 mins.
[071] ____/____/____ days Auto-test report Disabled
[072] ____/____/____ rings Number of rings 008 rings
[073] ____/____/____ seconds TLM fail timer 032 secs.
[074] ____/____/____ seconds Answering machine override delay 030 secs.
[075] ____/____/____ seconds Delay alarm transmission Disabled
V
[076] ____/____/____ seconds (maximum 130 seconds) Delay between dialing attempts 020 secs.
[077] ____/____/____ seconds Pager/voice delay 005 secs.
[078] ____/____/____ seconds Remote panic disarm lock delay 020 secs.
[079] ____/____/____ repetitions (maximum 10 repetitions) Voice reporting message repetitions 003 reps.
[080] ____/____/____ days Closing delinquency delay Disabled
[081] ____/____/____ (000 to 007**) Entry delay audio selection ( J[4] J[4] ) 003
[082] ____/____/____ (000 to 007**) Exit delay audio selection ( J[4] J[4] ) 002
[083] ____/____/____ attempts (maximum 10 attempts) Voice/utility dialing attempts 003 atts.
[084] ____/____:____/____ Hours Auto-test report time Disabled
[085] ____/____:____/____ Hours Auto-arm time ( J[8] J[3] ) Disabled
** 000 = No tone; 001 = Beeping; 002 = Countdown; 003 = Tonality 1; 004 = Tonality 2; 005 = Tonality 3; 006 = Tonality 4;
007 = Radio tuner (MG6160 only)
For UL installations, the Entry delay must not exceed 45 seconds. * For UL installations, the Bell cut-off time must be a minimum of 4 minutes; for
For UL installations, the Exit delay must not exceed 60 seconds. cUL installations, the Bell cut-off time must be a minimum of 5 minutes.
V For UL installations, the number of dialing attempts shall not exceed 10.
Refer to Appendix 1: PGM Event Table on page 19 for the PGM events that can be used to program Magellans PGM outputs.
6 Programming Guide
System Options
[090] General Options Bold = Default setting
Option OFF ON
[1] Access code length 6 digits 4 digits
[2] Audible trouble warning (except AC power failures) Disabled Enabled
[3] Lock master code Disabled Enabled
[4] Use user code 16 as duress code Disabled Enabled
[5] Console tamper supervision Disabled Enabled
[6] Need code to bypass zones Disabled Enabled
[7] PGM1 normal state N.O. N.C.
[8] PGM2 normal state N.O. N.C.
Magellan 7
[094] Zone Options Bold = Default setting
Option OFF ON
[1] Stay delay zones Disabled Enabled
[2] Report zone restore On Bell cut-off On zone closure
[3] & [4] Tamper recognition options See table See table
[3] [4] See table See table
OFF OFF - Disabled
OFF ON - Trouble only
ON OFF - Disarmed: Trouble only
- Armed: Follow zones alarm type (page 4)
ON ON - Disarmed: Audible alarm
- Armed: Follow zones alarm type (page 4)
[5] Generate tamper trouble if detected on bypassed zone No Yes
[6] & [7] Wireless transmitter supervision options See table See table
[6] [7] See table See table
OFF OFF - Disabled *
OFF ON - Trouble only
ON OFF - Disarmed: Trouble only
- Armed: Follow zones alarm type (page 4)
ON ON - Disarmed: Audible alarm
- Armed: Follow zones alarm type (page 4)
[3] & [4] Doorbell 2 tone options See table See table
[3] [4]
See table See table
OFF OFF - Tone 1
OFF ON - Tone 2
ON OFF - Tone 3
ON ON - Tone 4
8 Programming Guide
[098] Dialer Options Bold = Default setting
Option OFF ON
[1] & [2] Telephone line monitoring options * See table See table
[1] [2]
See table See table
OFF OFF - TLM disabled
OFF ON - Generate a trouble
ON OFF - Generate audible alarm if armed
ON ON - Silent alarms become audible
* For UL installations, the telephone line monitoring must be enabled if off-premise transmission is used.
Magellan 9
Communicator Settings
Section Data Description
[105] ____/____/____ Report format for monitoring station telephone number 1 ( J[4] J[3] )
[106] ____/____/____ Report format for monitoring station telephone number 2 ( J[4] J[3] )
001 = Ademco slow (1400Hz 10BPS) 002 = Silent Knight (1400Hz 20BPS) 003 = SESCOA (2300Hz 20BPS)
004 = Ademco Contact ID (default) 005 = SIA FSK 006 = ADEMCO Express (DTMF 4+2)
[108] ____/____/____/____ Panel identifier (for use with WinLoad software) ( J[4] J[9] )
[109] ____/____/____/____ Panel password (for use with WinLoad software) ( J[4] J[9] )
[111] Monitoring station telephone number 1 (32 digits maximum; if less than 32, press [ok] to accept) ( J[4] J[3] )
___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___
[112] Monitoring station telephone number 2 (32 digits maximum; if less than 32, press [ok] to accept) ( J[4] J[3] )
___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___
[113] Pager Telephone # (32 digits maximum; if less than 32, press [ok] to accept) ( J[4] J[3] )
___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___
[114] Numeric message sent with Pager Reporting (32 digits maximum; if less than 32, press [ok] to accept) ( J[4] J[3] )
___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___
[115] PC telephone number for WinLoad (32 digits maximum; if less than 32, press [ok] to accept)
___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___
[116] Service telephone number* (32 digits maximum; if less than 32, press [ok] to accept) ( J[4] J[3] ) (MG6160 only)
___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___
* Using Magellans speakerphone feature (MG6160 only), the Service telephone number allows the user to directly call the installer or maintenance staff if any problems arise.
If you are using any report format other than SIA in sections [105] and [106] and you would like to transmit an A, press [0] on the main keypad; if you would like to enter a
space (non-reportable digit), press the [1] key on the center keypad.
[#] #
Center [ACTION] (pause) key Add a 4-second pause to the telephone number. Press the key and a P will be inserted into the telephone number
There are five personal telephone numbers used for voice reporting. These telephone numbers are programmed through the
consoles communicator menu. ( J[4] J[3] )
10 Programming Guide
Report Codes
Default = FF
Arming Report Codes Special Arming Report Codes Disarming Report Codes Special Disarming Report Codes
Sec- Sec-
Data Data Section Data Section Data
tion tion
[120] ____/____ User Code 1 [124] ____/____ Auto-arming [126] ____/____ User Code 1 [130] ____/____ End auto-arm
____/____ User Code 2 ____/____ Late to close ____/____ User Code 2 ____/____ Disarm via PC
____/____ User Code 3 ____/____ No movement ____/____ User Code 3 ____/____ Alarm cancelled via PC
____/____ User Code 4 ____/____ Partial arming ____/____ User Code 4 ____/____ Non-medical alarm
cancelled
[121] ____/____ User Code 5 [125] ____/____ Quick-arming [127] ____/____ User Code 5
____/____ User Code 6 ____/____ Arming via PC ____/____ User Code 6
____/____ User Code 7 ____/____ Future use ____/____ User Code 7
____/____ User Code 8 ____/____ Future use ____/____ User Code 8
Default = FF
Alarm Report Codes Alarm Report Codes Alarm Restore Report Codes Alarm Restore Report Codes
Section Data Section Data Section Data Section Data
[131] ____/____ Zone 1 [135] ____/____ Zone 17 [139] ____/____ Zone 1 [143] ____/____ Zone 17
____/____ Zone 2 ____/____ Zone 18 ____/____ Zone 2 ____/____ Zone 18
____/____ Zone 3 ____/____ Zone 19 ____/____ Zone 3 ____/____ Zone 19
____/____ Zone 4 ____/____ Zone 20 ____/____ Zone 4 ____/____ Zone 20
[132] ____/____ Zone 5 [136] ____/____ Zone 21 [140] ____/____ Zone 5 [144] ____/____ Zone 21
____/____ Zone 6 ____/____ Zone 22 ____/____ Zone 6 ____/____ Zone 22
____/____ Zone 7 ____/____ Zone 23 ____/____ Zone 7 ____/____ Zone 23
____/____ Zone 8 ____/____ Zone 24 ____/____ Zone 8 ____/____ Zone 24
[133] ____/____ Zone 9 [137] ____/____ Zone 25 [141] ____/____ Zone 9 [145] ____/____ Zone 25
____/____ Zone 10 ____/____ Zone 26 ____/____ Zone 10 ____/____ Zone 26
____/____ Zone 11 ____/____ Zone 27 ____/____ Zone 11 ____/____ Zone 27
____/____ Zone 12 ____/____ Zone 28 ____/____ Zone 12 ____/____ Zone 28
[134] ____/____ Zone 13 [138] ____/____ Zone 29 [142] ____/____ Zone 13 [146] ____/____ Zone 29
____/____ Zone 14 ____/____ Zone 30 ____/____ Zone 14 ____/____ Zone 30
____/____ Zone 15 ____/____ Zone 31 ____/____ Zone 15 ____/____ Zone 31
____/____ Zone 16 ____/____ Zone 32 ____/____ Zone 16 ____/____ Zone 32
Magellan 11
Default = FF
Special Alarm Report Codes Tamper Report Codes Tamper Report Codes Tamper Restore Report Codes
Section Data Section Data Section Data Section Data
[147] ____/____ Emer. panic [149] ____/____ Zone 1 [153] ____/____ Zone 17 [157] ____/____ Zone 1
____/____ Aux. panic ____/____ Zone 2 ____/____ Zone 18 ____/____ Zone 2
____/____ Fire panic ____/____ Zone 3 ____/____ Zone 19 ____/____ Zone 3
____/____ Recent closing ____/____ Zone 4 ____/____ Zone 20 ____/____ Zone 4
[148] ____/____ Zone shutdown [150] ____/____ Zone 5 [154] ____/____ Zone 21 [158] ____/____ Zone 5
____/____ Duress ____/____ Zone 6 ____/____ Zone 22 ____/____ Zone 6
____/____ Paramedical ____/____ Zone 7 ____/____ Zone 23 ____/____ Zone 7
____/____ Future use ____/____ Zone 8 ____/____ Zone 24 ____/____ Zone 8
Default = FF
Tamper Restore Report Codes System Trouble Report Codes System Troubles Restore Report Special Report Codes
Codes
Section Data Section Data Section Data Section Data
[161] ____/____ Zone 17 [165] ____/____ Future use [168] ____/____ Future use [171] ____/____ Cold start
____/____ Zone 18 ____/____ AC failure ____/____ AC failure ____/____ Test report
____/____ Zone 19 ____/____ Battery failure ____/____ Battery failure ____/____ Future use
____/____ Zone 20 ____/____ Timer loss ____/____ Timer prog. ____/____ WinLoad
logout
[162] ____/____ Zone 21 [166] ____/____ Unit tamper [169] ____/____ Unit tamp. rest. [172] ____/____ Installer logon
____/____ Zone 22 ____/____ Fail to comm. ____/____ Future use ____/____ Installer logout
____/____ Zone 23 ____/____ TX low battery ____/____ TX low battery ____/____ Delinquency
____/____ Zone 24 ____/____ TX superv. loss ____/____ TX superv. rest. ____/____ Future use
12 Programming Guide
Default = FF
Wireless Module Trouble Report Wireless Module Trouble Restore Report Wireless Siren Trouble Report Codes
Codes Codes
____/____ PGM Supervision ____/____ PGM Supervision ____/____ Tamper
[173] [175] [177]
Loss Restored
____/____ PGM Tamper ____/____ PGM Tamper ____/____ Supervision Loss
Restored
____/____ Keypad ____/____ Keypad Supervision ____/____ Battery Trouble
Supervision Restored
Loss
____/____ Keypad Battery ____/____ Keypad Battery ____/____ AC Failure
Trouble Trouble Restored
Wireless Siren Trouble Restore Report
Codes
____/____ Keypad AC ____/____ Keypad AC Restored ____/____ Tamper Restored
[174] [176] [178]
Failure
____/____ Repeater ____/____ Repeater Supervision ____/____ Supervision Restored
Supervision Lost Restored
____/____ Repeater Battery ____/____ Repeater Battery ____/____ Battery Trouble
Trouble Trouble Restored Restored
____/____ Repeater AC ____/____ Repeater AC ____/____ AC Restored
Failure Restored
System Settings
Section Data Description Default
Magellan 13
Wireless Output Assignment
Wireless output assignment may be done through the consoles menu ( J[4] J[7] ). Alternatively, assign the PGM by entering its serial
number in the corresponding section:
Section Serial Number Section Serial Number
[235] PGM1: ____/____/____/____/____/____ [239] PGM5: ____/____/____/____/____/____
[236] PGM2: ____/____/____/____/____/____ [240] PGM6: ____/____/____/____/____/____
[237] PGM3: ____/____/____/____/____/____ [241] PGM7: ____/____/____/____/____/____
[238] PGM4: ____/____/____/____/____/____ [242] PGM8: ____/____/____/____/____/____
14 Programming Guide
Wireless PGM Timer
Section Data Description Default
[280] ____/____/____ (000 to 008) Wireless PGM1 timer 000
[281] ____/____/____ (000 to 008) Wireless PGM2 timer 000
[282] ____/____/____ (000 to 008) Wireless PGM3 timer 000
[283] ____/____/____ (000 to 008) Wireless PGM4 timer 000
[284] ____/____/____ (000 to 008) Wireless PGM5 timer 000
[285] ____/____/____ (000 to 008) Wireless PGM6 timer 000
[286] ____/____/____ (000 to 008) Wireless PGM7 timer 000
[287] ____/____/____ (000 to 008) Wireless PGM8 timer 000
000 = No delay; 001 = 1s delay; 002 = 5s delay; 003 = 15s delay; 004 = 30s delay; 005 = 1min delay; 006 = 5min delay;
007 = 15min delay; 008 = 30min delay.
Magellan 15
[294] Wireless PGM Supervision Options Bold = Default setting
Option OFF ON
[1] Wireless PGM1 supervision Disabled Enabled
[2] Wireless PGM2 supervision Disabled Enabled
[3] Wireless PGM3 supervision Disabled Enabled
[4] Wireless PGM4 supervision Disabled Enabled
[5] Wireless PGM5 supervision Disabled Enabled
[6] Wireless PGM6 supervision Disabled Enabled
[7] Wireless PGM7 supervision Disabled Enabled
[8] Wireless PGM8 supervision Disabled Enabled
[297] Wireless PGM Console Supervision Options (Follow Alarm/Follow Bell) Bold = Default setting
Option OFF ON
[1] PGM1 console supervision Disabled Enabled
[2] PGM2 console supervision Disabled Enabled
[3] PGM3 console supervision Disabled Enabled
[4] PGM4 console supervision Disabled Enabled
[5] PGM5 console supervision Disabled Enabled
[6] PGM6 console supervision Disabled Enabled
[7] PGM7 console supervision Disabled Enabled
[8] PGM8 console supervision Disabled Enabled
Note: For information on supervising communication between the MG6160 and the 2WPGM, refer to the Magellan Reference and Installation Manual.
16 Programming Guide
Wireless Repeater Options
RPT1 #1 RPT1 #2
Wireless Repeater Options Bold = Default setting
[300] [306]
Option OFF ON OFF ON
[1] Repeat Wireless Zone 1 Signals N N
[2] Repeat Wireless Zone 2 Signals N N
[3] Repeat Wireless Zone 3 Signals N N
[4] Repeat Wireless Zone 4 Signals N N
[5] Repeat Wireless Zone 5 Signals N N
[6] Repeat Wireless Zone 6 Signals N N
[7] Repeat Wireless Zone 7 Signals N N
[8] Repeat Wireless Zone 8 Signals N N
RPT1 #1 RPT1 #2
Wireless Repeater Options Bold = Default setting
[301] [307]
Option OFF ON OFF ON
[1] Repeat Wireless Zone 9 Signals N N
[2] Repeat Wireless Zone 10 Signals N N
[3] Repeat Wireless Zone 11 Signals N N
[4] Repeat Wireless Zone 12 Signals N N
[5] Repeat Wireless Zone 13 Signals N N
[6] Repeat Wireless Zone 14 Signals N N
[7] Repeat Wireless Zone 15 Signals N N
[8] Repeat Wireless Zone 16 Signals N N
Magellan 17
RPT1 #1 RPT1 #2
Wireless Repeater Options Bold = Default setting
[302] [308]
Option OFF ON OFF ON
[1] Repeat Wireless Zone 17 Signals N N
[2] Repeat Wireless Zone 18 Signals N N
[3] Repeat Wireless Zone 19 Signals N N
[4] Repeat Wireless Zone 20 Signals N N
[5] Repeat Wireless Zone 21 Signals N N
[6] Repeat Wireless Zone 22 Signals N N
[7] Repeat Wireless Zone 23 Signals N N
[8] Repeat Wireless Zone 24 Signals N N
RPT1 #1 RPT1 #2
Wireless Repeater Options Bold = Default setting
[303] [309]
Option OFF ON OFF ON
[1] Repeat Wireless Zone 25 Signals N N
[2] Repeat Wireless Zone 26 Signals N N
[3] Repeat Wireless Zone 27 Signals N N
[4] Repeat Wireless Zone 28 Signals N N
[5] Repeat Wireless Zone 29 Signals N N
[6] Repeat Wireless Zone 30 Signals N N
[7] Repeat Wireless Zone 31 Signals N N
[8] Repeat Wireless Zone 32 Signals N N
RPT1 #1 RPT1 #2
Wireless Repeater Options Bold = Default setting
[303] [309]
Option OFF ON OFF ON
[1] Repeat Wireless 2-Way PGM 1 Signals N N
[2] Repeat Wireless 2-Way PGM 2 Signals N N
[3] Repeat Wireless 2-Way PGM 3 Signals N N
[4] Repeat Wireless 2-Way PGM 4 Signals N N
[5] Repeat Wireless 2-Way PGM 5 Signals N N
[6] Repeat Wireless 2-Way PGM 6 Signals N N
[7] Repeat Wireless 2-Way PGM 7 Signals N N
[8] Repeat Wireless 2-Way PGM 8 Signals N N
RPT1 #1 RPT1 #2
Wireless Repeater Options Bold = Default setting
[304] [310]
Option OFF ON OFF ON
[1] Repeat Wireless Keypad 1 Signals N N
[2] Repeat Wireless Keypad 2 Signals N N
[3] Repeat Wireless Keypad 3 Signals N N
[4] Repeat Wireless Keypad 4 Signals N N
[5] Repeat Doorbell 1 Signals N N
[6] Repeat Doorbell 2 Signals N N
[7] & [8] Future Use N N
18 Programming Guide
Appendix 1: PGM Event Table
Event Group # Sub-group #
00 = Zone closed 01 to 32 = Zone number
01 = Zone opened 99 = Any zone number
02 = System status 00 = N/A
01 = N/A
02 = Silent alarm
03 = Buzzer alarm
04 = Steady alarm
05 = Pulsed alarm
06 = Strobe
07 = Siren stopped
08 = Squawk ON*
09 = Squawk OFF*
10 = Ground start
11 = System disarmed
12 = System armed
13 = Entry delay engaged
99 = Any system status event
03 = Bell status 00 = Bell OFF
01 = Bell ON
02 = Bell Squawk Arm
03 = Bell Squawk Disarm
04 = Future use Future use
05 = Non-reportable event 00 = Telephone line trouble
01 = Future use
02 = Arm with no entry delay
03 = Arm in Stay mode
04 = Arm in Force mode
05 = Full arm when armed in Stay mode
06 = PC fail to communicate
07 = Future use
08 = Future use
* Squawk ON/OFF is similar to Bell ON/OFF except it follows the arming/disarming even if section [093] option [3] is disabled (no
bell squawk when arming/disarming with remote control). These 2 events are used to activate/deactivate a light, strobe, or any
other PGM with squawk activation/deactivation capabilities.
Magellan 19
Event Group # Sub-group #
12 = Delay zone alarm transmission 01 to 32 = Zone number
99 = Any zone number
13 = Arming with user 01 to 16 = User number
99 = Any user number
14 = Special arming 00 = Auto-arming
01 = Late to close
02 = No movement arming
03 = Partial arming
04 = Quick arming
05 = Arming through WinLoad
99 = Any special arming event
15 = Disarming with user
01 to 16 = User number
16 = Disarm after alarm with user *
99 = Any user number
17 = Alarm cancelled with user **
18 = Special disarming 00 = Auto-arm cancelled
01 = Disarm through WinLoad
02 = Disarm through WinLoad after alarm *
03 = Alarm cancelled through WinLoad **
04 = Non-medical alarm cancelled
99 = Any special disarming event
19 = Zone bypassed
20 = Zone in alarm
01 to 32 = Zone number
21 = Fire alarm
99 = Any zone number
22 = Zone alarm restore
23 = Fire alarm restore
24 = Special alarm 00 = Panic non-medical emergency
01 = Panic medical (this medical panic alarm is not UL approved)
02 = Panic fire
03 = Recent closing
04 = Global shutdown
05 = Duress alarm (User 16)
99 = Any special alarm event
25 = Zone shutdown
01 to 32 = Zone number
26 = Zone tampered
99 = Any zone number
27 = Zone tamper restore
28 = New trouble 00 = N/A
01 = AC failure
02 = Battery failure
03 = Clock loss
04 = Console tamper
05 = Fail to communicate to monitoring station
06 = Fail to communicate to voice report
07 = Fail to communicate to pager
08 = RF jamming supervision
99 = Any new trouble event
29 = Trouble restored 00 = Telephone line restored
01 = AC failure
02 = Battery failure
03 = Clock lost
04 = Console tamper restore
05 = N/A
06 = N/A
07 = N/A
08 = RF jamming restore
99 = Any trouble restore event
30 = Low battery on zone
31 = Low battery on zone restore 01 to 32 = Zone number
32 = Zone supervision trouble 99 = Any zone number
33 = Zone supervision restored
* An armed system is or was in alarm and was disarmed by a user.
** A disarmed system is or was in alarm (e.g. 24Hr. zone) and was disarmed by a user.
20 Programming Guide
Event Group # Sub-group #
34 = Special 00 = System power up
01 = Reporting test
02 = WinLoad logon
03 = WinLoad logoff
04 = Installer in programming mode
05 = Installer exited programming mode
06 = Closing delinquency delay elapsed
99 = Any special event
35 = Non-medical alarm 01 to 16 = User number
99 = Any user number
36 = Zone triggered a utility report
37 = Signal strength weak 1
01 to 32 = Zone number
38 = Signal strength weak 2
99 = Any zone number
39 = Signal strength weak 3
40 = Signal strength weak 4
41 & 42 = Reserved Reserved
43 = PGM supervision lost
44 = PGM supervision restored 01 to 08 = PGM number
45 = PGM tampered 99 = Any PGM number
46 = PGM tamper restored
47 = Wireless keypad supervision lost
48 = Wireless keypad supervision restored
49 = Wireless keypad battery trouble 01 to 04 = Keypad number
50 = Wireless keypad battery trouble restored 99 = Any keypad number
51 = Wireless keypad AC failure
52 = Wireless keypad AC failure restored
53 = Wireless repeater supervision lost
54 = Wireless repeater supervision restored
55 = Wireless repeater battery trouble 01 to 02 = Repeater number
56 = Wireless repeater battery trouble restored 99 = Any repeater number
57 = Wireless repeater AC failure
58 = Wireless repeater AC failure restored
59 = Wireless siren tampered
60 = Wireless siren tamper restored
61 = Wireless siren supervision lost
62 = Wireless siren supervision restored 01 to 04 = Siren number
63 = Wireless siren battery trouble 99 = Any siren number
64 = Wireless siren battery trouble restored
65 = Wireless siren AC failure
66 = Wireless siren AC failure restored
80 = Fire delay started 01 to 32 = Zone number
81= Fire delay cancelled 99 = Any zone number
82 = PGM cold start 01 to 08 = PGM number
99 = Any PGM number
83 = Keypad cold start 01 to 04 = Keypad number
99 = Any keypad number
84 = Repeater cold start 01 to 02 = Repeater number
99 = Any repeater number
85 = Wireless siren cold start 01 to 04 = Siren number
99 = Any siren number
90 = User remote access granted 01 to 16 = User number
99 = Any user number
91 = PGM activation via phone 01 to 08 = PGM number
99 = Any PGM number
Magellan 21
Appendix 2: Specifications
Input Voltage 12Vac to 16Vac* 20VA or 12Vdc to 18Vdc 1A
Max. Current Consumption 1A
Backup Battery 7.2Vdc NiMH rechargeable battery pack (order # 0780100178)
PGM1: N.O. solid-state relay (not polarized); Internal resistance 16 9(max.): Max. handling current
2 PGMs 100mA
PGM2: One low powered open-collector; Max. handling current 50mA
Standby Battery Life Minimum 24 hours
Temperature Range 0C to 50C (32F to 122F)
When using an AC or DC power source, the auxiliary output provides 13.8V (200mA maximum)
Auxiliary Output
When a power failure occurs, the auxiliary output will drop to 7Vdc (backup battery)
Approvals
* It is recommended that you use a 12Vac 1A transformer to power the Magellan console. The console will generate less heat when
connected to a 12Vac transformer than when connected to a 16.5Vac transformer.
To achieve this value, use a minimum of 15Vdc.
DC Power
Supply
-
+
22 Programming Guide
Figure 4: Connecting the Battery
- +
Magellan 23
Telephone Line Connections
Figure 6: Telephone Line Direct Connect
Telephone Line Connection Note
The Magellan console must be able to seize the telephone line and place a
call in an emergency situation. It must be able to do this even if other
equipment (telephones, answering machines, computer modems, etc.)
already has the line in use. To do so, the Magellan console must be
connected to a properly installed RJ31X (or RJ38X) jack that is electrically
in series with and ahead of all other equipment attached to the same
telephone line. Proper installation is depicted in the diagram below. If you
have any questions concerning these instructions, you should consult your
telephone company or a qualified installer about installing the RJ31X (or
RJ38X) jack and the Magellan console for you.
Do not connect
the RJ-11 cable
into this plug.
24 Programming Guide
PGM Connections
Figure 8: PGM1 Connections
Back view of the Magellan console.
Method 1
(less than 100mA)
Method 2
(exceeds 100mA) External DC Devices
Power Supply such as a
light, etc.
Devices
External such as a
relay light, etc.
External DC
Power Supply
Devices
such as a
Method 2 External DC
light, etc.
(exceeds 50mA) Power Supply
Method 3
(less than 50mA)
External
relay
Devices
such as a
light, etc.
External DC Devices
Power Supply such as a
light, etc.
Magellan 25
Hardwire Zone Connections
Figure 10: Hardwire Zone Connections
26 Programming Guide
Connecting to a UIP256
Figure 12: Connecting to a UIP256 Universal In-Field Programmer
Connect the 10- Back view of the
pin cable of the Magellan console.
UIP256 to the 10-
pin connector of
the Magellan
console
Standard
DB-9 cable
UIP256
(9-pin serial
Universal
cable)
In-Field
Programmer
Download latest
firmware version of
Magellan from the
Paradox website at
paradox.com
1. Connect one end of the inverted Back view of the Magellan console.
4-pin RJ-11 cable into the X10
plug of the console.
2. Connect the other end of the
inverted 4-pin RJ-11 cable into the
X10 transmitter. Do not connect the X10
3. Plug the X10 transmitter into a transmitter into this plug.
standard wall outlet.
For information on
programming the X10 1
features of Magellan, refer to
the X10 Operation User
Inverted 4-pin
Guide which can be found
RJ-11 cable
and downloaded for free
from our Web site at
paradox.com.
3
X10 devices (transmitters,
modules, etc.) are not
supplied and cannot be Make sure that an inverted 4-pin
purchased through Paradox RJ-11 cable is used when
Security Systems Ltd. connecting the Magellan console to
the X10 transmitter. Note the pin
configuration below:
Magellan X10
Console Transmitter
Inverted Pin 1 Pin 4
4-pin
RJ-11 Pin 2 Pin 3
cable Pin 3 Pin 2
Pin 4 Pin 1
X10 transmitter 2
Magellan 27
Connecting Magellan to WinLoad
Figure 14: Connecting Magellan to WinLoad
Back view of the
Magellan console.
4- to 10-pin cable
(supplied with the
306 306 Adapter)
Adapter
Computer Standard
containing DB-9 cable
WinLoad (9-pin serial
software cable) 4-pin
connector
cable
PMC5
Jumper ON:
Read from and/or write to memory key
Jumper OFF:
Write protected (Read from the memory key
only)
Download Data to Destination Console The installer code of the Magellan console used to
To download the data of a memory key into a console: download data to the memory key must be the same
installer code programmed in the Magellan console that is
1. Remove power from the Magellan console (AC and battery) and
to download the contents from the same memory key. If the
connect the memory key to the 5-pin connector on the left side of the
installer codes do not match, the contents of the memory
back of the console as shown above.
key cannot be downloaded into the receiving console.
2. Re-apply both AC and battery power to the console.
3. Press the [OK] key and Magellan will begin downloading the data from Example: The contents of the Magellan console A will be
the memory key. copied into memory key B. The installer code for console A
is 111111. In order to download the contents of memory key
Copy Data to Memory Key from Source Console B into the Magellan console C, the installer code
To copy the contents of a console into the memory key. programmed in console C must also be 111111.
1. Remove power from the Magellan console (AC and battery) and
connect the memory key to the 5-pin connector on the left side of the
back of the console as shown above. Re-apply both AC and battery
power to the console.
2. Press the [NEXT] key and then the [OK] key. Magellan will begin
copying its data into the memory key.
28 Programming Guide
Tabletop Mounting
Figure 16: Tabletop Mounting
Plastic feet (x2) To mount the Magellan console on a tabletop
the wall plate has to be inserted beforehand:
1. Slide the wall plates tabs labeled B into the
Back view of the Magellan consoles open slots labeled D
Magellan console. (see Figure 17 on page 29).
2. Insert two screws (included) through the wall
plates screw holes labeled C into holes
labeled E in the Magellan console (see
Wall plate Figure 17 on page 29).
3. Insert the two plastic feet (included) into the
appropriate holes on the back plate of the
Magellan console as shown at left.
4. Attach the two rubber stops (included) to the
lower edge of the wall plate as shown at left.
D D
A (x7)
C E
Magellan 29
Appendix 4: Ademco Contact ID Report Codes
CID# Reporting Code Programming CID# Reporting Code Programming CID# Reporting Code Programming
Value Value Value
Medical Alarms - 100 151 Gas detected 26 327 Notification appliance chk. #4 4E
100 Medical alarm * 01 152 Refrigeration 27 System Peripheral Troubles - 330 and 340
102 Fail to report in 03 154 Water leakage 29 331 Polling loop open 50
Fire Alarms - 110 155 Foil break 2A 332 Polling loop short 51
110 Fire alarm 04 156 Day trouble 2B 333 Expansion module failure 52
111 Smoke 05 157 Low bottled gas level 2C 334 Repeater failure 53
112 Combustion 06 158 High temperature 2D 335 Local printer paper out 54
113 Water flow 07 159 Low temperature 2E 336 Local printer failure 55
114 Heat 08 161 Loss of air flow 2F 337 Exp. module DC loss 56
115 Pull station 09 162 Carbon monoxide detected 30 338 Exp. module low battery 57
117 Flame 0B Fire Supervisory - 200 and 210 341 Exp. module tamper 59
118 Near alarm 0C 200 Fire supervisory 32 342 Exp. module AC loss 5A
Panic Alarms - 120 201 Low water pressure 33 343 Exp. module self-test fail 5B
120 Panic Alarm 0D 202 Low CO2 34 344 RF receiver jam detect 5C
121 Duress 0E 203 Gate valve sensor 35 Communication Troubles - 350 and 360
124 Duress - Access grated 206 Pump failure 38 352 Telco 2 fault 5F
125 Duress - Egress granted 12 System Troubles - 300 and 310 353 Long range radio 60
131 Perimeter 14 302 Low system battery 3B 356 Loss of central polling 63
132 Interior 15 303 RAM checksum bad 3C 357 Long range radio VSWR prob. 64
135 Day/Night 18 306 Panel program changed 3F 371 Protection loop open 66
138 Near alarm 1B 309 Battery test failure 42 374 Exit error alarm 69
139 Intrusion verified 1C 310 Ground fault 43 375 Panic zone trouble 6A
General Alarms - 140 311 Battery missing/dead 44 376 Hold-up zone trouble 6B
140 General alarm 1D 312 Power supply over current limit 45 377 Swinger trouble 6C
141 Polling loop open 1E 313 Engineer reset 46 378 Cross-zone trouble 6D
142 Polling loop short 1F Sounder/Relay Troubles - 320 Sensor Troubles - 380 and 390
145 Expansion module tamper 22 322 Bell 2 49 382 Loss of supervision - RPM 70
147 Sensor supervision failure 24 324 Trouble relay 4B 384 RF transmitter low battery 72
24-hour Non-burglary - 150 and 160 325 Reversing relay 4C 385 Smoke detector Hi sensitivity 73
150 24-hour non-burglary 25 326 Notification appliance chk. #3 4D 386 Smoke detector Low sensitivity 74
30 Programming Guide
CID# Reporting Code Programming CID# Reporting Code Programming CID# Reporting Code Programming
Value Value Value
387 Intrusion detector Hi sensitivity 75 451 Early open/close 9A 603 Periodic RF transmission BF
388 Intrusion detector Low 76 452 Late open/close 9B 604 Fire test C0
sensitivity
389 Sensor self-test failure 77 453 Failed to open 9C 605 Status report to follow C1
391 Sensor watch trouble 78 454 Failed to close 9D 606 Listen-in to follow C2
392 Drift compensation error 79 455 Auto-arm failed 9E 607 Walk test mode C3
393 Maintenance alert 7A 456 Partial arm 9F 608 Periodic test - system trouble C4
present
Open/Close - 400 457 Exit error (user) A0 609 Video transmitter active C5
401 Open/Close by user 7C 459 Recent close A2 612 Point not tested C7
402 Group open/close 7D System - 460 613 Intrusion zone walk tested C8
403 Automatic open/close 7E 461 Wrong code entry A3 614 Fire zone walk tested C9
404 Late to open/close 5E 462 Legal code entry A4 615 Panic zone walk tested CA
405 Deferred open/close 5F 463 Re-arm after alarm A5 616 Service request CB
406 Cancel 7F 464 Auto-arm time extended A6 621 Event log reset CC
407 Remote arm/disarm 80 465 Panic alarm reset A7 622 Event log 50% full CD
408 Quick arm 81 466 Service ON/OFF premises A8 623 Event log 90% full CE
409 Keyswitch open/close 82 Sounder Relay Disabled - 520 624 Event log overflow CF
411 Call back request made 83 521 Bell 1 disabled AA 626 Time/Date inaccurate D1
412 Success - download access 84 522 Bell 2 disabled AB 627 Program mode entry D2
413 Unsuccessful access 85 523 Alarm relay disabled AC 628 Program mode exit D3
414 System shutdown 86 524 Trouble relay disabled AD 629 32-hour event log marker D4
415 Dialer shutdown 87 525 Reversing relay disabled AE 630 Schedule change D5
416 Successful upload 88 526 Notification appliance chk. #3 AF 631 Exception schedule change D6
disabled
Access Control - 420 and 430 527 Notification appliance chk. #4 B0 632 Access schedule change D7
disabled
421 Access denied 89 Modules - 530 654 System inactivity D8
Magellan 31
Appendix 5: Automatic Report Code List
System Event Default Contact ID Report Code Default SIA Report Code
when using sections [790] to [795] when using sections [790] to [795]
Arming with Master Code (##) 3 4A1 - Close by user CL - Closing Report
Arming with User Code (##) 3 4A1 - Close by user CL - Closing Report
Arming with Keyswitch (##) 3 4A9 - Keyswitch Close CS - Closing Keyswitch
Auto Arming 3 4A3 - Automatic Close CA - Automatic Closing
Arm with PC software 3 4A7 - Remote arm/disarm CL - Closing Report
Late To Close 3 4A4 - Late to Close OT - Late to Close
No Movement 3 4A4 - Late to Close NA - No Activity
Partial arming 1 574 - Group bypass CG - Close Area
Quick arming 3 408 - Quick arm CL - Closing Report
Closing Delinquency 1 654 - System Inactivity CD - System Inactivity
Disarm with Master Code (##) 1 4A1 - Open by user OP - Opening Report
Disarm with User Code (##) 1 4A1 - Open by user OP - Opening Report
Disarm with Keyswitch (##) 1 4A9 - Keyswitch Open OS - Opening Keyswitch
Disarm after alarm* with Master Code (##) 1 4A1 - Open by user OP - Opening Report
Disarm after alarm* with User Code (##) 1 4A1 - Open by user OP - Opening Report
Disarm after alarm* with Keyswitch (##) 1 4A1 - Keyswitch Open OS - Opening Keyswitch
Cancel alarm** with Master Code (##) 1 4A6 - Open by user OR - Disarm from Alarm
Cancel alarm** with User Code (##) 1 4A6 - Open by user OR - Disarm from Alarm
Cancel alarm** with Keyswitch (##) 1 4A6 - Keyswitch Open OS - Opening Keyswitch
32 Programming Guide
System Event Default Contact ID Report Code Default SIA Report Code
when using sections [790] to [795] when using sections [790] to [795]
AC Failure 1 3A1 - AC loss AT - AC Trouble
Battery Failure 1 3A9 - Battery test failure YT - System Battery Trouble
Auxiliary supply trouble 1 3AA - System trouble YP - Power Supply Trouble
Bell output current limit 1 321 - Bell 1 YA - Bell Fault
Bell absent 1 321 - Bell 1 YA - Bell Fault
Clock lost 1 626 - Time/Date inaccurate JT - Time Changed
Fire loop trouble 1 373 - Fire trouble FT - Fire Trouble
TLM trouble restore 3 351 - Telco 1 fault restore LR - Phone Line restoral
AC Failure restore 3 3A1 - AC loss restore AR - AC Restoral
Battery Failure restore 3 3A9 - Battery test restore YR - System Battery Restoral
Auxiliary supply trouble restore 3 3AA - System trouble restore YQ - Power Supply restored
Bell output current limit restore 3 321 - Bell 1 restore YH - Bell Restored
Bell absent restore 3 321 - Bell 1 restore YH - Bell Restored
Clock programmed 3 625 - Time/Date Reset JT - Time Changed
Fire loop trouble restore 3 373 - Fire trouble restore FJ - Fire Trouble Restore
Bus fault restore 3 333 - Expansion module failure restore ER - Expansion Restoral
Module tamper restore 3 145 - Expansion module tamper restore TR - Tamper Restoral
Module ROM_RAM_error restore 3 3A4 - Rom checksum bad restore YG - Parameter Changed
Module TLM restore 3 352 - Telco 2 fault restore LR - Phone Line Restoral
Printer fault restore 3 336 - Local printer failure restore VR - Printer Restore
Module AC restore 3 3A1 - AC loss restore AR - AC Restoral
Module battery restore 3 3A9 - Battery test failure restore YR - System Battery Restoral
Module Auxiliary supply restore 3 3AA - System trouble restore YQ - Power Supply Restored
Fail to communicate with monitoring station 1 354 - Fail to communicate YC - Communication Fails
Module RF low battery 1 384 - RF transmitter low battery XT - Transmitter Battery Trouble
Module RF battery restore 3 384 - RF transmitter battery restore XR - Transmitter Battery Restoral
Module RF supervision trouble 1 381 - Loss of supervision - RF US - Untype Zone Supervision
Module RF supervision restore 3 381 - Supervision restore - RF UR - Untyped Zone Restoral
Magellan 33
Installer Menu Overview
Ready to arm 1-bypass zones
menu 2-alarm clock
3-time and date
Must enter the 4-system
installer, maintenance 1-language
setup
or user code to 2-user profile
access 3-communicator
central report? add tel. # 1 add backup # account number report format
voice report? add tel.#1 TEL#2 TEL#3 TEL#4 TEL.#5 record alrm mes?
utility report? add tel. # 1 add tel. # 2 report type? record alrm mes?
pager report? add tel. # 1 add message?
add service tel? tel.:
(MG6160 only)
11-signal strength
Your security system should therefore be considered as one of many tools available to reduce risk and/or damage of burglary, fire or other emergencies, such other tools include but are not limited to insurance
coverage, fire prevention and extinguish devices, and sprinkler systems.
We also strongly recommend that you regularly maintain your security systems and stay aware of new and improved Paradox products and developments.
For example, if your VoIP equipment has no battery back-up, during a power failure your system's ability to transmit signals to the central station may be compromised. Or, if your VoIP connection becomes
disabled, your telephone line monitoring feature may also be compromised. Other concerns would include, without limitation, Internet connection failures which may be more frequent than regular telephone line
outages.
We therefore strongly recommend that you discuss these and other limitations involved with operating an alarm system on a VoIP or other non-traditional telephone system with your installation company. They
should be able to offer or recommend measures to reduce the risks involved and give you a better understanding.
TBR-21
In order to comply with TBR-21, standard force dialing must be enabled.
CERTIFICATON
For the latest information on product approvals, such as UL and CE, please visit www.paradox.com.
Legal
2010 Paradox Security Systems Ltd. All rights reserved. Specifications may change without prior notice. One or more of the following US patents may apply: 7046142, 6215399, 6111256, 6104319,
5920259, 5886632, 5721542, 5287111, 5119069, 5077549 and RE39406. Canadian and international patents may also apply. Magellan is a trademark or registered trademark of Paradox Security Systems
Ltd. or its affiliates in Canada, the United States and/or other countries.
.
PARADOX.COM
PRINTED IN CANADA - 05/2010 MAGELLAN-EP09