UPS systems

IUPS-301
300 VA

Integrated UPS
Communications interface
Temperature controlled

Other than conventional uninterruptable power supplies the


IUPS-301 was designed to be installed into a PC. Thus, UPS and
PC become one compact space-saving unit. The IUPS-301 can
easily be installed into a drive slot and its handling is exceptional-
ly user-friendly. Via interface and the UPS management software
RUPS 2000 OEM the computer will be shut down and switched
off in case of mains power failure.

Te c h n i c a l d a t a
Output power 300 VA / 180 W
Input voltage 230 V AC 15 %
Input frequency 50 Hz 5 %
Output voltage 230 VAC 15 %
Output frequency 50 Hz 1 %
Charging time 68 h
UPS Classification / Wave form VFD / rectangular
Specification is subject to change without notice. Errors excepted. Windows is a trademark of Microsoft Inc. Status as at: 15.06.2011

Power factor 0.6


Overload protection UPS mode: switch off / mains mode: fuse
Transfer time <4 ms
Back up time 100 W / 166 VA load app. 5 minutes
180 W / 300 VA load app. 23 minutes
Interface DSUB 9-pole for UPS management software
Safety / EMC CE
Windows is a registered trademark of Microsoft Corp., NetWare is a registered trademark of Novell.

Operating temperature 040 C


Storage temperature 040 C
Dimensions 146 x 41.5 x 248 mm 0.8 mm
Weight (net) 2.75 kg

Product specific data


Type of battery 2 x 6 V / 3 Ah, maintenance-free lead batteries (VRLA)
Noise development <35 dbA
Load sensor Switch off at <20 Watt
Status display Mains mode: LED green
Back-up mode: LED yellow
Battery low: LED red
Overtemperature: LED red
Acoustic alarms Power failure, every 5 seconds
Battery low, every second
AC UPS

Test function Test button at the front panel to check UPS function

Optional accessory
Article No. Description
RUPS 2000 OEM UPS management software: WIN 3.X, 95, 98, NT, ME, 2000, 2003, XP, Vista, 7,
Novell NetWare, OS/2, UNIX, LINUX, others on request
During storage the IUPS-301 has to be charged at least every 6 months.

Bicker ElektronikGmbH || Zirgesheimer Strae 31 || 86609 Donauwrth || Germany


Tel. +49 906 70595-0 || Fax +49 906 70595-55 || E-Mail [email protected] || www.bicker.de