FOUNDATION Fieldbus H1 is one of the FOUNDATION fieldbus protocol versions. FOUNDATION H1 (31.25 kbit/s) is a bi-directional communications protocol used for communications among field devices and to the control system.

Uploaded by

MsKaroly
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
106 views4 pages

Foundation Fieldbus H1

FOUNDATION Fieldbus H1 is one of the FOUNDATION fieldbus protocol versions. FOUNDATION H1 (31.25 kbit/s) is a bi-directional communications protocol used for communications among field devices and to the control system.

Uploaded by

MsKaroly
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Foundation Fieldbus H1

FOUNDATION Fieldbus H1 is one of the FOUNDATION fieldbus protocol versions.


FOUNDATION Fieldbus H1
FOUNDATION H1 (31.25 kbit/s) is a bi-directional communications protocol used for
Protocol Information
communications among field devices and to the control system. It utilizes either
twisted pair, or fiber media to communicate between multiple nodes (devices) and Type of Process Control
the controller. The controller requires only one communication point to Network
communicate with up to 32 nodes, this is a significant improvement over the Physical Twisted Pair, fiber
standard 4-20 mA communication method which requires a separate connection Media
point for each communication device on the controller system.
Network Star, Bus
From a business standpoint, FOUNDATION Fieldbus technology delivers savings in Topology
total installation costs. H1 Fieldbus reduces instrument wiring, which means less Maximum 32 nodes/segment
termination and fewer screwdriver turns. The technology reduces hardware Devices
requirements and lowers Capital Expenditures (CAPEX). FOUNDATION Fieldbus Maximum 9500 meters with 4
primarily reduces Operating Expenses (OPEX) through improved plant efficiencies, Distance repeaters(depending
better asset management, and reduced maintenance requirements.Specific benefits of on minimum signal
FOUNDATION technology include: reduced wiring, multi-variables from a single strength and power to
multi-channel field instrument, simpler integration and easier maintenance. Using reach the field
Half Duplex RS485 hardware connection a two wire communication is possible. devices)

The FOUNDATION Fieldbus H1 has support for Intrinsically Safe Wiring. Unlike
Device Automatic when
Addressing connected to segment
other protocols, FOUNDATION H1 provides explicit synchronization of control and
communication for precisely periodic (isochronous) communication and execution Governing FieldComm Group
of control functions with minimized dead time and jitter. It synchronizes clocks in Body
fieldbus devices for support of Function Block scheduling and alarm time-stamping Website www.fieldcommgroup
at the point of detection. .org

The original concept was to connect as many fields devices as possible on controller field connection, limited only by signal strength.

Contents
1 FOUNDATION HSE
2 Parameters
3 Communication Methods
4 Use
5 Power Supply
6 Termination
7 Intrinsically Safe Fieldbus
8 Development
9 See also
10 External links

FOUNDATION HSE
FOUNDATION HSE is a control network technology specifically designed for process automation to connect higher-level devices such
as controllers and remote-I/O, high-density data generators etc., and for horizontal integration of subsystems.

FOUNDATION HSE is based on unmodified IEEE 802.3 Ethernet and, therefore, is compatible with standard Ethernet equipment.
Unlike mere "ring topology, FOUNDATION HSE provides complete "DCS style" redundancy with redundant network switches,
redundant devices, and redundant communication ports ensuring unsurpassed availability. FOUNDATION HSE is also based on
standard IP, enabling it to coexist with other devices and ensuring compatibility with standard tools. At the highest level,
FOUNDATION HSE includes a standard application layer that provides interoperability between devices beyond the mere coexistence
provided by Ethernet and TCP/IP. FOUNDATION HSE communication is schedule-driven to minimize dead-time and jitter with
support for peer-to-peer communication directly between devices. Again, a rigorous interoperability testing program ensures quality
connectivity.

The hub-and-spoke tree topology of Ethernet makes it very easy to add and remove devices without upsetting the operating network.
Because FOUNDATION HSE is based on unmodified Ethernet, standard Ethernet tools can be used for installation qualification,
testing, and troubleshooting. These tools speed up the resolution of communication problems. FOUNDATION HSE is supported by
better troubleshooting tools not available for RS485 and coax. Since FOUNDATION HSE is based on UDP and TCP, standard network
management tools employing SNMP,RMON, etc., can be used. Similarly, familiar IP addressing is used including support for DHCP
.

Parameters
The communication line can stretch 1900 meters without repeaters or 9500 meters with up to 4 allowed repeaters.

Communication Methods
The communication methods supported are:

Client/Server
The Client/Server VCR Type is used for queued, unscheduled, user initiated, one to one, communication between devices on the
fieldbus. Queued means that messages are sent and received in the order submitted for transmission, according to their priority,
without overwriting previous messages.

Publisher/Subscriber
The Publisher/Subscriber VCR Type is used for buffered, one-to-many communications. Buffered means that only the latest version
of the data is maintained within the network. New data completely overwrites previous data.

Report Distribution
The Report Distribution VCR Type is used for queued, unscheduled, user initiated, and one-to man
y communications.

Use
This protocol is primarily used for analog and discrete process control devices. The primary advantage is configuration by functional
block concept.

Power Supply
The big advantage of FOUNDATION Fieldbus is that it allows power to be transferred over the communication bus to the controlled
devices, this requires a FOUNDATION Fieldbus power supply. Power supplies are normally redundant type with rating of 32 V DC
with 500 mA current, and are mostly installed in the Marshalling Cabinet or System Cabinet in the Control Room.

Termination
Every field bus segment needs exactly two terminators to operate properly. The terminators are designed to be the equivalent of a
1 F capacitor and a 100 resistor in series. The terminators serve several purposes including shunting the Fieldbus current(device
communication) and protecting against electrical reflections. The primary function of terminators is to act as a current shunt for the
control network. Fieldbus communication works by the field device modulating its current draw. When the devices need to transmit
data, the FF devices will act as a current sink. The devices will draw less current to represent a high signal (1, one) and draw more
current to represent a low signal (0, zero). As the modulating current of the FF devices is between 15 mA and 20 mA peak to peak,
while the modulating voltage in the bus caused by this modulating current is between 0.75 V and 1 V peak to peak. This 0.75 and
1 V is simply a result of the 15 mA x 50 which equal to 0.75 V and 20 mA x 50 which is equal to 1 V. The 50 resistor is an
equivalent of two parallel resistors from the FF terminator. Because of all devices use the same cable, only one device can transmit a
message at any given time. Without the proper number of terminators, the signal level will be out of specification and can disrupt the
network. Because of all devices use the same cable, only one device can transmit a message at any given time.

Another function of the terminator is to reduce the impact of electrical reflections.

Intrinsically Safe Fieldbus


There are several Intrinsically Safe Fieldbus technologies in the market. The most commonly used are:

Entity Barrier Concept


This Design takes the concept of normal Field barriers that has been successfully used in the analog signal world(4-20 mA). These
barriers use an infallible resistor (wire-wound), Zener diodes and a fuse, and require a good intrinsically safe ground. While this
barrier limited energy sufficient for Zone 0/1 all Gas Groups (Class I Div 1 all Gas Groups), it only provides 80 mA for the Fieldbus
segment. This optimistically could only power four Fieldbus devices which typically take 15-26 mA each. The Entity barrier concept
is safe, but its low power limitations and engineering requirements ef
fectively eliminate many of the benefits of using bus technology
.

FISCO
Fieldbus Intrinsically Safe Concept (FISCO), which was first developed by PTB (Physikalisch-Technische Bundesanstalt, the
national metrological institute of Germany) as a method to provide higher power to a Fieldbus segment in hazardous areas. The
FISCO concept, considers the entire circuit of the Fieldbus segment. The maximum total cable length in a FISCO system is 1 km in
Gas Groups A and B (IIC) and 1.9 km in Gas Groups C and D (IIA and IIB), while the maximum allowed spur length (length from
the segment junction box/protector) is 60 metres for Gas Groups A through D (IIC, IIB and IIA). Additional constraints are also
placed on the power conditioners i.e. load-sharing redundant power conditioners are not allowed in a FISCO power supply
.

Certifying devices to a standard before implementation, allows them to be integrated into systems without the engineering
requirements necessitated by the Entity approach. This then allows FISCO power supplies to generate more power (and allow more
devices per segment) than the Entity barrier solution. The bottleneck of this solution is that it requires each part of the system,
including devices, cables and power conditioners to be FISCO compliant and that FISCO design and installation rules are strictly
followed. While it does provide more power than the Entity barrier approach, still the system can only support four to five devices
per segment as the trunk current is limited to 15 mA.

HPT with Field Barriers


A more recent enhancement for intrinsically safe applications is the High Power Trunk (HPT) with field-based field barriers (FBs),
which limits power at the spur, rather than the trunk.This method significantly changes the equation for end users of Fieldbus in
hazardous settings. It increases the amount of available power and therefore the number of connected devices on a segment. It also
lets end users maximize the length of their trunk cables without the restrictions of FISCO/Entity Barrier Concept.

While the HPT model does provide some significant improvements(500 mA at Fieldbus segment), it is not without its downsides.
The field barrier is in essence a field-based isolated power conditioner. So even though the segment can be powered by load-sharing
redundant power conditioners at the host, the practical MTBF (Mean Time Before Failure) is still that of a single power conditioner,
since most field barriers are not redundant.

Intrinsically Safe-High Power Trunk/High Power Intrinsically Safe Trunk (HPIST)


The High Power IS Trunk (HPIST) technique provides an enhanced level of safety and simplicity in installation, along with the
ability to use it for all devices (FISCO and Entity) and hazardous Zones and Divisions. It delivers approximately 350 mA of IS power
to segments located in hazardous areas.

This is achieved by utilizing a split-architecture design that puts part of the barrier in an isolator card located in the safe area (power
supply rack) & the other part in each of the spurs of field-mounted device couplers/segment. The barrier in the isolator allows
350 mA to be run through the segment up to the Spur/junction Box through trunk cable. Since infallible resistors are used, devices
from Zone 0/1 or 2 can be direct connected. Having 350 mA, now allows users to power up to 16 Fieldbus devices (20 mA each) at
500 m while retaining intrinsic safety.

Development
This protocol is developed, enhanced and supported byFieldComm Group

See also
Computer networking
Computer science

External links
http://www.fieldbus.org/
http://www.pepperl-fuchs.com
[1]
[2]

Retrieved from "https://en.wikipedia.org/w/index.php?title=Foundation_Fieldbus_H1&oldid=791495021


"

This page was last edited on 20 July 2017, at 17:06.

Text is available under theCreative Commons Attribution-ShareAlike License ; additional terms may apply. By using this
site, you agree to the Terms of Use and Privacy Policy. Wikipedia is a registered trademark of theWikimedia
Foundation, Inc., a non-profit organization.

You might also like