Accord XPC User
Accord XPC User
IU1-1230 Issue B
Important: ZONE LOCATION CHART
1. Ensure all system detectors are clear before proceeding.
2. Ensure all windows and doors are secure.
ZONE LOCATION RF (ON/OFF)
LED KEYPAD PROGRAMMING
Setting the System
1
FULL SET [1]
To FULL SET the system:
2
1. Enter the User Code.
2. Press 1 (Full Set).
3
A constant exit tone will sound. During the exit period, the DAY LED will flash and
the exit tone will become broken as the user passes detectors on the exit route. The
exit tone will become constant, when the last detector on the exit route has been 4
passed. Two confirmation beeps indicate that the system has set.
Note: To stop the system from setting during the exit period press Ö. When the
system has set, Ö will no longer function. Press # + 1 (Full Set) to
5
EASY SET the system, if available.
Selected areas will set using the Part Set function. The engineer will programme
which selected areas will set with user approval, (see System Settings). 7
To PART SET the system:
1. Enter the User Code. 8
2. Press 2 (Part Set).
A constant exit tone will sound. During the exit period, the DAY LED will flash and
the exit tone will become broken as the user passes detectors on the exit route. The
exit tone will become constant, when the last detector on the exit route has been
passed. Two confirmation beeps indicate that the system has set.
Note: To stop the system from setting during the exit period press Ö.
When the system has set, Ö will no longer function.
Press # + 2 (Part Set) to EASY SET the system, if available
2 15
ALARM SYSTEM SETTINGS NIGHT SET [3]
Night Set permits the user to set the system in selected areas, whilst others are unset,
e.g. unset in bedrooms whilst set in remaining rooms of house. This permits
FULL PART NIGHT freedom of movement in the secure environment.
ZONE SET SET SET
1 To NIGHT SET the system:
If the panel has been programmed to accept only an Engineer Reset after an alarm
an Engineer Code is required to RESET the system.
X: Zones which are active in each set mode.
A Technistore Reset is required if all the LEDs illuminate simultaneously followed
by a 5 digit series of numbers indicated by the LEDs lighting in sequence. This
code is given to the monitoring station to obtain an anti-code which can be entered
to RESET the system.
Note: If the system does not reset Contact the alarm company.
14 3
Testing the System [5] Hot Keys
To TEST the system: LC D
1. Enter the User Code.
H o t K ey Type K eyp ad N 0
Display
2. Press 5 (TEST).
1 Assistance 4+6
Note: The outside bell/sounder will ring for 5 seconds and the strobe will flash until
the test is finished. All LEDS on the keypad will light up for 5 seconds. Test each
zone individually when the keypad stops scrolling and the bell/sounder stops
2 Fire 7+9
ringing. Activate the zone to verify display of zone on the LCD, two beeps will
sound. To exit test mode enter the User Code and wait for two beeps. 3 Panic Ö+#
e.g. To omit zones 6, 7 and 8, press 1234 6 678. Zone LED 6, 7 and 8 will flash.
Additional Information
Press Ö or wait 5 seconds.
Night-time :
Unsetting the system, will restore normal operation and all zones.
Hotkey Enabled : Yes / No
4
13
System Indications Changing Codes [8]
FUNCTIONS LCD KEYPAD LED KEYPAD The system can support up to 8 separate user codes.
ALARM/TEST Zone no.(solid) ZONE LED (solid) PROGRAMMING OTHER USER CODES INTO THE SYSTEM
LINE FAULT (solid) TELEPHONE LED (solid) The Master Code is used to programme new User Codes into the system:
COMMS FAIL (flashing) TELEPHONE LED (flashing) 1. Enter Master Code (e.g. 5678).
2. Press 8 (Code).
LOCKOUT -- (solid) All LED's (flashing)
3. Press 2 (User 2).
PA HOTKEY PA (solid) All LED's (solid) 4. Enter User 2 Code (e.g. 4321).
FIRE HOTKEY (solid) All LED's (flashing in sequence) Users can programme their own new User Codes into the system:
1. Enter User Code (e.g. 4321).
ASSIST HOTKEY (solid) All LED's (flashing alternate)
ENG. MODE (flashing) POWER LED (flashing) Any user may delete their own code by entering their CODE + 8 + USER No + Ö:
DURESS - User Code 8 may have been reserved for a DURESS CODE. This
type of code can perform all normal system functions, but will send a silent
DURESS Signal to your monitoring station
12 5
Setting the Date and Time Setting the Date and Time
The system contains a clock which is used to record the DATE AND TIME of each The system contains a clock which is used to record the DATE AND TIME of each
event as it occurs. event as it occurs.
1. Enter User Code. The most recent alarm zones are displayed first on the LCD with a single beep.
2. Press 0.
The most recent alarm zones are displayed first, indicated by the zone LED and a
single beep.
6 11
Changing Codes LCD KEYPAD PROGRAMMING
The system can support up to 8 separate user codes. Setting the System
DURESS - User Code 8/ may have been reserved for a DURESS CODE. This Note: To stop the system from setting during the exit period press Ö.
type of code can perform all normal system functions, but will send a silent When the system has set, Ö will no longer function.
DURESS Signal to your monitoring station Press # + 2/ (Part Set) to EASY SET the system, if available.
10 7
NIGHT SET Testing the System
Night Set permits the user to set the system in selected areas, whilst others are unset, To TEST the system:
e.g. unset in bedrooms whilst set in remaining rooms of house. This permits
freedom of movement in the secure environment. 1. Enter the User Code.
2. Press 5/ (TEST).
To NIGHT SET the system:
The outside bell/sounder will ring for 5 seconds and the strobe will flash until the
1. Enter the User Code. test is finished. The keypad LCD scrolls through zone numbers 1-8 for 5 seconds.
2. Press 3/ (NIGHT SET).
Note: Test each zone individually when the keypad stops scrolling and the
During the exit period, the DAY LCD symbol will flash. Two confirmation bell/sounder stops ringing. Activate the zone to verify display of zone on
beeps indicate that the system has set. the LCD, two beeps will sound. To exit test mode enter the User Code and
wait for two beeps.
Note: To stop the system from setting during the exit period press Ö.
When the system has set, Ö will no longer function.
Press # + 3/ (Night Set) to EASY SET the system, if available.
Omitting Zones
To OMIT Zones:
Unsetting the System
1. Enter the user code.
To UNSET the system: 2. Press 6/ (OMIT).
1. Proceed to a keypad via the approved route and enter the User Code. 3. Enter the Zone Number(s) to be omitted.
4. Press Ö to finish or wait 5 seconds for confirmation beep.
Resetting the System 5. Set the system
To UNSET and RESET the system during or after an alarm: e.g. To omit zones 6, 7 and 8, press 1234 6/ 678. Zone No. 6, 7 and 8 will
flash. Press Ö or wait 5 seconds for confirmation.
Entering a User Code will stop any alarm in progress. The zone number causing the
initial alarm will then be displayed on the LCD keypad. The User Code may be
To correct a wrong omitted zone:
entered again to RESET the system.
If the panel has been programmed to accept only an Engineer Reset after an alarm 1. Enter the User Code
an Engineer Code is required to RESET the system. 2. Press 6/ (Omit)
3. Press Ö or wait for a confirmation beep.
If the panel has been programmed to accept only a Technistore Reset the keypad
will flash the cE symbol followed by the activated zone number. The cE symbol Note: Fire, Silent PA and PA cannot be omitted.
will then flash again followed by a five digit code which should be given to the
monitoring station who will then issue an anticode. This anticode will RESET the
system when entered on the keypad. Unsetting the system, will restore normal operation and all zones.
8 9