USER INSTRUCTIONS

LED Keypad Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2


Full Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Part Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Night Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Unsetting the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Resetting the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Testing the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Omitting Zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Changing Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Setting the Time and Date . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Chime Facility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Viewing the Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

LCD Keypad Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7


Full Set .................................................. 7
Part Set .................................................. 7
Night Set ................................................. 8
Unsetting the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Resetting the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Testing the System .......................................... 9
Omitting Zones ........................................... 9
Changing Codes .......................................... 10
Setting the Time and Date . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Chime Facility ............................................. 11
Viewing the Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
System Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Hot Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Additional Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Alarm System Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Zone Location Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

IU1-1230 Issue B
Important: ZONE LOCATION CHART
1. Ensure all system detectors are clear before proceeding.
2. Ensure all windows and doors are secure.
ZONE LOCATION RF (ON/OFF)
LED KEYPAD PROGRAMMING
Setting the System
1
FULL SET [1]
To FULL SET the system:
2
1. Enter the User Code.
2. Press 1 (Full Set).
3
A constant exit tone will sound. During the exit period, the DAY LED will flash and
the exit tone will become broken as the user passes detectors on the exit route. The
exit tone will become constant, when the last detector on the exit route has been 4
passed. Two confirmation beeps indicate that the system has set.

Note: To stop the system from setting during the exit period press Ö. When the
system has set, Ö will no longer function. Press # + 1 (Full Set) to
5
EASY SET the system, if available.

PART SET [2] 6

Selected areas will set using the Part Set function. The engineer will programme
which selected areas will set with user approval, (see System Settings). 7
To PART SET the system:
1. Enter the User Code. 8
2. Press 2 (Part Set).

A constant exit tone will sound. During the exit period, the DAY LED will flash and
the exit tone will become broken as the user passes detectors on the exit route. The
exit tone will become constant, when the last detector on the exit route has been
passed. Two confirmation beeps indicate that the system has set.

Note: To stop the system from setting during the exit period press Ö.
When the system has set, Ö will no longer function.
Press # + 2 (Part Set) to EASY SET the system, if available
2 15
ALARM SYSTEM SETTINGS NIGHT SET [3]
Night Set permits the user to set the system in selected areas, whilst others are unset,
e.g. unset in bedrooms whilst set in remaining rooms of house. This permits
FULL PART NIGHT freedom of movement in the secure environment.
ZONE SET SET SET
1 To NIGHT SET the system:

1. Enter the User Code.


2. Press 3 (NIGHT SET).
2
No exit tone will sound during the exit period, however the DAY LED will flash as
3 the user passes detectors on the exit route. Two confirmation beeps indicate that the
system has set.
Note: To stop the system from setting during the exit period press Ö.
4 When the system has set, Ö will no longer function.
Press # + 3 (Night Set) to EASY SET the system, if available.

5 Unsetting the System


To UNSET the system:
6
1. Proceed to a keypad via the approved route and enter the User Code.

7 Resetting the System


To UNSET and RESET the system during or after an Alarm:
Entering a User Code will stop any alarm in progress. The zone LED causing the
8 initial alarm will then be displayed on the keypad. The User Code may be entered
again to reset the system.

If the panel has been programmed to accept only an Engineer Reset after an alarm
an Engineer Code is required to RESET the system.
X: Zones which are active in each set mode.
A Technistore Reset is required if all the LEDs illuminate simultaneously followed
by a 5 digit series of numbers indicated by the LEDs lighting in sequence. This
code is given to the monitoring station to obtain an anti-code which can be entered
to RESET the system.
Note: If the system does not reset Contact the alarm company.
14 3
Testing the System [5] Hot Keys
To TEST the system: LC D
1. Enter the User Code.
H o t K ey Type K eyp ad N 0
Display
2. Press 5 (TEST).
1 Assistance 4+6
Note: The outside bell/sounder will ring for 5 seconds and the strobe will flash until
the test is finished. All LED’S on the keypad will light up for 5 seconds. Test each
zone individually when the keypad stops scrolling and the bell/sounder stops
2 Fire 7+9

ringing. Activate the zone to verify display of zone on the LCD, two beeps will
sound. To exit test mode enter the User Code and wait for two beeps. 3 Panic Ö+#

Omitting Zones [6]


To Omit Zones: Hot keys are convenient and specific for the alarms specified above.

1. Enter the user code. e.g. To trigger a fire alarm.


2. Press 6 (Omit).
3. Enter the Zone Number(s) to be isolated. 1. Press 7 + 9.
4. Press Ö to finish or wait 5 seconds. 2. Fire alarm will sound (pulse tone), all LEDs ON/ .
5. Set the system 3. Enter User Code to exit alarm mode.

e.g. To omit zones 6, 7 and 8, press 1234 6 678. Zone LED 6, 7 and 8 will flash.
Additional Information
Press Ö or wait 5 seconds.

To correct a wrong omitted zone: Entry Time : Exit Time :

1. Enter the User Code Easy SET : Yes / No


2. Press 6 (Isolate)
3. Press Ö or wait for a confirmation beep. Alarm Company Telephone Number :

Note: Fire, Silent PA and PA cannot be isolated. Daytime :

Night-time :
Unsetting the system, will restore normal operation and all zones.
Hotkey Enabled : Yes / No

4
13
System Indications Changing Codes [8]
FUNCTIONS LCD KEYPAD LED KEYPAD The system can support up to 8 separate user codes.

DAY MODE (solid) DAY LED (solid) MASTER CODE: User 1.

The Master Code (User 1) can be changed:


FULL SET (flashing) DAY LED (flashing)

PART SET (flashing) DAY LED (flashing)


1. Enter Master Code (e.g. 1234).
NIGHT SET (flashing) DAY LED (flashing)
2. Press 8 (Code).
ZONE 9 TAMPER (flashing) TAMPER LED (solid) 3. Press 1 (User 1).
4. Enter new User Code (e.g. 5678). Two beeps confirms code acceptance.
ZONAL TAMPER (solid) + zone no. TAMPER LED + ZONE LED (flashing)

ALARM/TEST Zone no.(solid) ZONE LED (solid) PROGRAMMING OTHER USER CODES INTO THE SYSTEM
LINE FAULT (solid) TELEPHONE LED (solid) The Master Code is used to programme new User Codes into the system:
COMMS FAIL (flashing) TELEPHONE LED (flashing) 1. Enter Master Code (e.g. 5678).
2. Press 8 (Code).
LOCKOUT -- (solid) All LED's (flashing)
3. Press 2 (User 2).
PA HOTKEY PA (solid) All LED's (solid) 4. Enter User 2 Code (e.g. 4321).
FIRE HOTKEY (solid) All LED's (flashing in sequence) Users can programme their own new User Codes into the system:
1. Enter User Code (e.g. 4321).
ASSIST HOTKEY (solid) All LED's (flashing alternate)

OMIT (solid) + zone no. ZONE LED (flashing) 2. Press 8 (Code).


BATT. MISSING (solid) X flashing BAT LED (solid)
3. Press 2 (User 2).
4. Enter new User 2 Code (9876).
BATTERY LOW (solid) X flashing BAT LED (solid)

MAINS FAIL (flashing) POWER LED OFF DELETING USER CODES

ENG. MODE (flashing) POWER LED (flashing) Any user may delete their own code by entering their CODE + 8 + USER No + Ö:

1. Enter User 2 Code (e.g. 9876).


2. Press 8 (Code).
3. Press 2 (User 2).
4. Press Ö.
Note: The MASTER CODE can delete any USER CODE.

“DURESS - User Code 8 may have been reserved for a DURESS CODE. This
type of code can perform all normal system functions, but will send a silent
DURESS Signal to your monitoring station”
12 5
Setting the Date and Time Setting the Date and Time
The system contains a clock which is used to record the DATE AND TIME of each The system contains a clock which is used to record the DATE AND TIME of each
event as it occurs. event as it occurs.

To Set the clock: To Set the clock:

1. Enter User Code. 1. Enter User Code.


2. Press # + 0. 2. Press # + 0.
3. Enter ddmmyyhhmm (day, month, year, hour, minute). Two confirmation beeps 3. Enter ddmmyyhhmm (day, month, year, hour, minute). Two confirmation beeps
acknowledge correct entry. acknowledge correct entry.

Note: Users cannot view time Chime Facility


Chime Facility [9] Any zone can be programmed to give a CHIME (2 beeps from the keypad and 2
beeps from the internal sounder) when operating the zone.
Any zone can be programmed to give a CHIME (2 beeps from the keypad and 2
beeps from the internal sounder) when operating the zone. To programme a zone to Chime:

To programme a zone to Chime: 1. Enter User Code


2. Press 9/ (Chime)
1. Enter User Code 3. Enter zone number for Chime.
2. Press 9 (Chime) 4. Press Ö to finish or wait for confirmation beep.
3. Enter zone for Chime.
4. Press Ö to finish or wait for confirmation beep. To disable the Chime on all zones enter User Code, press 9 then Ö.
The Chime function cannot be disabled on individual zones. Entering and exiting
To disable the chime facility on all zones: programming mode will delete all Chimes.

1. Enter User Code Viewing the Log


2. Press 9 (Chime) and press Ö
The User can VIEW the last 16 alarm zones:
Viewing the Log [0]
1. Enter User Code.
The User can VIEW the last 16 alarm zones: 2. Press 0.

1. Enter User Code. The most recent alarm zones are displayed first on the LCD with a single beep.
2. Press 0.
The most recent alarm zones are displayed first, indicated by the zone LED and a
single beep.
6 11
Changing Codes LCD KEYPAD PROGRAMMING
The system can support up to 8 separate user codes. Setting the System

MASTER CODE: User 1. FULL SET


The Master Code (User 1) can be changed: To FULL SET the system:

1. Enter Master Code (e.g. 1234) 1. Enter the User Code.


2. Press 8/ (CODE) 2. Press 1/ (Full Set).
3. Press 1 (User 1)
4. Enter new User Code (e.g. 5678). Two beeps confirms code acceptance. A constant exit tone will sound. During the exit period, the DAY LCD symbol
™ will flash and the exit tone will become broken as the user passes detectors
PROGRAMMING OTHER USER CODES INTO THE SYSTEM
on the exit route. The exit tone will become constant, when the last detector on
The Master Code is used to programme new User Codes into the system: the exit route has been passed. Two confirmation beeps indicate that the system
has set.
1. Enter Master Code (e.g. 5678).
2. Press 8/ (Code).
Note: To stop the system from setting during the exit period press Ö. When
3. Press 2 (User 2).
4. Enter User 2 Code (e.g. 4321). the system has set, Ö will no longer function. Press # + 1 / (Full
Set) to EASY SET the system, if available.
Users can programme their own new User Codes into the system:
1. Enter User Code (e.g. 4321). PART SET
Selected areas will set using the Part Set function. The engineer will programme
2. Press 8/ (Code).
which selected areas will set with user approval, (see System Settings).
3. Press 2 (User 2).
4. Enter new User 2 Code (9876).
To PART SET the system:
DELETING USER CODES
1. Enter the User Code.
Any user may delete their own code by entering their CODE + 8 + USER No + Ö: 2. Press 2/ (Part Set).
1. Enter User 2 Code (e.g. 9876).
A constant exit tone will sound. During the exit period, the DAY LCD symbol
2. Press 8/ (Code).
™ will flash and the exit tone will become broken as the user passes detectors
3. Press 2 (User 2).
on the exit route. The exit tone will become constant, when the last detector on
4. Press Ö. the exit route has been passed. Two confirmation beeps indicate that the system
Note: The MASTER CODE can delete any USER CODE. has set

“DURESS - User Code 8/ may have been reserved for a DURESS CODE. This Note: To stop the system from setting during the exit period press Ö.
type of code can perform all normal system functions, but will send a silent When the system has set, Ö will no longer function.
DURESS Signal to your monitoring station” Press # + 2/ (Part Set) to EASY SET the system, if available.

10 7
NIGHT SET Testing the System
Night Set permits the user to set the system in selected areas, whilst others are unset, To TEST the system:
e.g. unset in bedrooms whilst set in remaining rooms of house. This permits
freedom of movement in the secure environment. 1. Enter the User Code.
2. Press 5/ (TEST).
To NIGHT SET the system:
The outside bell/sounder will ring for 5 seconds and the strobe will flash until the
1. Enter the User Code. test is finished. The keypad LCD scrolls through zone numbers 1-8 for 5 seconds.
2. Press 3/ (NIGHT SET).
Note: Test each zone individually when the keypad stops scrolling and the
During the exit period, the DAY LCD symbol ™ will flash. Two confirmation bell/sounder stops ringing. Activate the zone to verify display of zone on
beeps indicate that the system has set. the LCD, two beeps will sound. To exit test mode enter the User Code and
wait for two beeps.
Note: To stop the system from setting during the exit period press Ö.
When the system has set, Ö will no longer function.
Press # + 3/ (Night Set) to EASY SET the system, if available.
Omitting Zones
To OMIT Zones:
Unsetting the System
1. Enter the user code.
To UNSET the system: 2. Press 6/ (OMIT).
1. Proceed to a keypad via the approved route and enter the User Code. 3. Enter the Zone Number(s) to be omitted.
4. Press Ö to finish or wait 5 seconds for confirmation beep.
Resetting the System 5. Set the system

To UNSET and RESET the system during or after an alarm: e.g. To omit zones 6, 7 and 8, press 1234 6/ 678. Zone No. 6, 7 and 8 will
flash. Press Ö or wait 5 seconds for confirmation.
Entering a User Code will stop any alarm in progress. The zone number causing the
initial alarm will then be displayed on the LCD keypad. The User Code may be
To correct a wrong omitted zone:
entered again to RESET the system.
If the panel has been programmed to accept only an Engineer Reset after an alarm 1. Enter the User Code
an Engineer Code is required to RESET the system. 2. Press 6/ (Omit)
3. Press Ö or wait for a confirmation beep.
If the panel has been programmed to accept only a Technistore Reset the keypad
will flash the cE symbol followed by the activated zone number. The cE symbol Note: Fire, Silent PA and PA cannot be omitted.
will then flash again followed by a five digit code which should be given to the
monitoring station who will then issue an anticode. This anticode will RESET the
system when entered on the keypad. Unsetting the system, will restore normal operation and all zones.