Project Job Ref. Section Sheet No./rev. Calc. by Date CHK'D by Date App'd by Date

This document provides calculations for the design of a two-way reinforced concrete slab. Key details include: - The slab is 175mm thick with spans of 6000mm x 3000mm - Loads on the slab include a total factored load of 15 kN/m^2 - Moments are calculated in both the x and y directions for column and middle strips - Required flexural strengths are calculated per meter width of slab for the column and middle strips

Uploaded by

Amanda Smith
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
219 views3 pages

Project Job Ref. Section Sheet No./rev. Calc. by Date CHK'D by Date App'd by Date

This document provides calculations for the design of a two-way reinforced concrete slab. Key details include: - The slab is 175mm thick with spans of 6000mm x 3000mm - Loads on the slab include a total factored load of 15 kN/m^2 - Moments are calculated in both the x and y directions for column and middle strips - Required flexural strengths are calculated per meter width of slab for the column and middle strips

Uploaded by

Amanda Smith
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Project Job Ref.

Section Sheet no./rev.


1
Calc. by Date Chk'd by Date App'd by Date
D 8/20/2017

RC TWO-WAY SLAB DESIGN (ACI318-11)


TEDDS calculation version 1.2.01

lx x

Column strip
Middle strip
ly

Column strip
Column strip Middle strip Column strip

TWO-WAY SLAB PANEL

147 mm
175 mm

250 mm
Section at middle strip along X axis

Slab definition
Slab thickness; h = 175 mm
Span along x dir; lx = 6000 mm
Span along y dir; ly = 3000 mm
Long span to short span ratio less than 2, hence two-way slab
Clear cover to positive reinforcement; cc = 20 mm
Clear cover to negative reinforcement; cc = 20 mm
Effective flanged beam section
Flange width; bf = 1000 mm
Beam depth; hb = 650 mm
Beam width; bw = 450 mm
Materials
Specified compressive strength of concrete; fc = 28 MPa
Specified yield strength of reinforcement; fy = 415 MPa
Modulus of elasticity; ESACI = 199948MPa
Concrete type; Normal weight
Project Job Ref.

Section Sheet no./rev.


2
Calc. by Date Chk'd by Date App'd by Date
D 8/20/2017

Concrete modification factor; = 1.00

Loads
Total factored ultimate load on slab; wu = 15.00 kN/m2
Check for the depth of slab provided
Clear span x dir (13.6.2.5); lnx = max(0.65 lx, (lx - bw / 2 - bw / 2)) = 5550 mm
Clear span y dir (13.6.2.5); lny = max(0.65 ly, (ly - bw / 2 - bw / 2)) = 2550 mm
Ratio; = max(lnx, lny) / min(lnx, lny) = 2.176
Moment of inertia of beam; Ib = 14628994381 mm4
Moment of inertia of slab along x axis; Isx = 1339843750 mm4
Moment of inertia of slab along y axis; Isy = 2679687500 mm4
Flexural stiffness ratio along x axis; fx = Ib / Isx = 10.918
Flexural stiffness ratio along y axis; fy = Ib / Isy = 5.459
Average flexural stiffness ratio; fm = (fx 2 + fy 2) / 4 = 8.189
Minimum depth required (9.5.3); hmin = 110 mm
PASS - slab thickness provided is sufficient for deflection
Moment computation (x direction)
Width of column strip (half) (13.2.1); lcol_stp = min(0.25 lx, 0.25 ly) = 750 mm
Width of middle strip (13.2.2); lmid_stp_x = ly - 2 lcol_stp = 1500 mm
Factored moment (Eqn 13-4); Mox = wu ly lnx2 / 8 = 173.26 kNm
Moment distribution for interior panel (13.6.3.2); Mux = 0.65 Mox = 112.62 kNm
Mux = 0.35 Mox = 60.64 kNm
Moment distribution in column and middle strips
ly / lx = 0.50
fx ly / lx = 5.46
Moment distribution factors; fx_neg = 0.90
fx_pos = 0.90
Total column strip design moments; Mx_col_stp = fx_neg Mux = 101.36 kNm
Mx_col_stp = fx_pos Mux = 54.58 kNm
Column strip beam moments; Mx_beam = 86.16 kNm
Mx_beam = 46.39 kNm
Column strip slab moments; Mx_slab = Mx_col_stp - Mx_beam = 15.20 kNm
Mx_slab = Mx_col_stp - Mx_beam = 8.19 kNm
Total middle strip design moments; Mx_mid_stp = (1 - fx_neg) Mux = 11.26 kNm
Mx_mid_stp = (1 - fx_pos) Mux = 6.06 kNm
Required flexural nominal strength in column strip per 1 m width of slab
Mnx_col = Mx_slab / (0.9 (2 lcol_stp - bf)) = 33.79 kNm/m
Mnx_col = Mx_slab / (0.9 (2 lcol_stp - bf)) = 18.19 kNm/m
Required flexural nominal strength in middle strip per 1 m width of slab
Mnx_mid = Mx_mid_stp / (0.9 lmid_stp_x) = 8.34 kNm/m
Mnx_mid = Mx_mid_stp / (0.9 lmid_stp_x) = 4.49 kNm/m
Moment computation (y direction)
Width of column strip (half) (13.2.1); lcol_stp = min(0.25 lx, 0.25 ly) = 750 mm
Width of middle strip (13.2.2); lmid_stp_y = lx - 2 lcol_stp = 4500 mm
Factored moment (Eqn 13-4); Moy = wu lx lny2 / 8 = 73.15 kNm