OMRON Inverter PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 64

Inverters

Selection Guide
Table of contents

SYSDRIVE inverters Page

Inverter -- Outline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

3G3EV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
System architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Product overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Programming accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Connections diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Technical documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

3G3JV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
System architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Product overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Connections diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Set of parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

3G3MV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
System architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Product overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Connections diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Set of parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

3G3HV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
System architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Product overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Programming accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Connections diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Technical documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

3G3FV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
System architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Product overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Programming accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Connections diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Technical documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58

i
ii
Outline

Frequency inverters
In the field of drives OMRON offers five series of frequency inverters for standard three-phase motors: 3G3EV, 3G3JV, 3G3MV, 3G3HV and
3G3FV. These inverters can be run on all European and non-European single-phase and three-phase power supplies. The power spectrum
ranges from 0.1...300 kW at supply voltages from 200 ... 575 V (50/60 Hz).

OMRON frequency inverters are heavy-duty, application-oriented, user-friendly and communicative:

heavy-duty:
-- high rated current
-- built-in brake chopper up to 15 kW inverter power
-- high range of nominal voltage, i.e. 380 V (--10%) to 460 V (+ 15%)
-- high starting torque
-- short-circuit and earth-fault proof
-- error-free operation at short-time voltage breakdown

application-oriented:
-- integrated PID control
-- energy-saving algorithm
-- flux vector control
-- low-noise operation
-- brake management
-- numerous multifunctional inputs and outputs

communicative and user-friendly:


-- built-in serial interfaces
-- diverse bus couplings
-- standard built-in operating console
-- parameterising software under WINDOWS

Frequency inverter
Power

3G3HV 3G3FV

Programming software
SYSDRIVE Configurator
3G3EV/3G3JV/3G3MV/
3G3HV/3G3FV
3G3MV

3G3JV

3G3EV

simple fast process torque


speed control speed control control control

Functionality

1
Outline
Table of options according to application
Variable-frequency inverter
Power (kW) 0.1--1.5 0.1--4.0 0.1--7.5 0.4--4.0 4.0--15 18.5--300
Mains voltage (VAC) 1 x 230 1 x 230 1 x 230 1 x 230 3 x 400 3 x 400
3 x 230 (up to 1.5) 3 x 230 (up to 3.7)
3 x 400 3 x 230 3 x 400 3 x 400
3 x 400
Quadratic Fan, Pumps 3G3EV 3G3JV 3G3MV 3G3HV 3G3HV --
moment
Constant Lifts, Cranes -- -- 3G3MV -- 3G3FV 3G3FV
moment
steady load Conveyors 3G3EV 3G3JV 3G3MV 3G3HV 3G3HV/FV 3G3FV
Extruders -- -- -- -- 3G3FV 3G3FV
Heavy industry -- -- -- -- 3G3FV 3G3FV
Cyclical load Palletising 3G3EV -- 3G3MV -- 3G3HV/FV 3G3FV
Tooling machines -- -- -- -- 3G3FV 3G3FV
Presses -- -- -- -- 3G3FV 3G3FV
Robots -- -- -- -- -- --
Controlled Coil winders -- -- -- -- 3G3HV/FV 3G3FV
moment (thick material)
Coil winders -- -- -- -- 3G3FV 3G3FV
(sensitive material)
Spindles -- -- -- -- 3G3FV 3G3FV

2
3G3EV inverter
General

The 3G3EV is a miniature variable-frequency inverter of great reliabili-


ty due to a very high current-carrying capacity. The continuous output
current of the 3G3EV is about 20% above the rated current of a
four-pole standard motor.
Advantages are a high starting torque even when fully loaded and not
being susceptible to overload or shock loads. This increases the
operating time of your machine. Inputs and outputs are very flexible.
The analogue frequency default takes place via 4...20mA or 0...10V.
The digital inputs can be NPN or PNP.
Features:
-- compact design
-- NPN or PNP digital inputs
-- analogue frequency default: 0-10VDC or 4-20mA
-- high continuous output current
-- low noise thanks to 15 kHz carrier frequency
-- built-in operating console, also may be mounted on front panel
-- built-in brake chopper
-- UL/CSA and CE in one device
-- modbus
-- optional RS-232C interface and programming software

System architecture

To comply with relevant EMC guidelines it is imperative for


variable-frequency inverters to be operated with line filters.

Switch cabinet assembly


on metal plate
Voltage Contact surfaces to the
supply Shielding metal plate
L1
L2
L3
PE

Line filter,
footprint type

Shielding
U
V M
W
PE

3
3G3EV inverter
Product overview

Max. motor Output Rated Product number


output current voltage
Standard type* Multifunction type* Multifunction type
with optional modbus

Inverter for high starting torque, single phase 230 V


0,12 kW 0,8 A 1 x 230 VAC 3G3EV--AB001--CE 3G3EV--AB001M--CE 3G3EV--AB001MA--CUE (S1)**
0,25 kW 1,5 A 1 x 230 VAC 3G3EV--AB002--CE 3G3EV--AB002M--CE 3G3EV--AB002MA--CUE (S1)**
0,55 kW 3,0 A 1 x 230 VAC 3G3EV--AB004--CE 3G3EV--AB004M--CE 3G3EV--AB004MA--CUE (S1)**
1,1 kW 5,0 A 1 x 230 VAC 3G3EV--AB007--CE 3G3EV--AB007M--CE 3G3EV--AB007MA--CUE (S1)**
1,5 kW 7,0 A 1 x 230 VAC 3G3EV--AB015--CE 3G3EV--AB015M--CE 3G3EV--AB015MA--CUE (S1)**

Inverter for low starting torque, single phase 230 V


0,1 kW 0,8 A 3 x 230 VAC 3G3EV--A2001--CE 3G3EV--A2001M--CE 3G3EV--A2001MA--CUE (S1)**
0,2 kW 1,5 A 3 x 230 VAC 3G3EV--A2002--CE 3G3EV--A2002M--CE 3G3EV--A2002MA--CUE (S1)**
0,4 kW 3,0 A 3 x 230 VAC 3G3EV--A2004--CE 3G3EV--A2004M--CE 3G3EV--A2004MA--CUE (S1)**
0,75 kW 5,0 A 3 x 230 VAC 3G3EV--A2007--CE 3G3EV--A2007M--CE 3G3EV--A2007MA--CUE (S1)**
1,5 kW 7,0 A 3 x 230 VAC 3G3EV--A2015--CE 3G3EV--A2015M--CE 3G3EV--A2015MA--CUE (S1)**

Inverter for high starting torque, 3 phase 400 V


0,37 kW 1,2 A 3 x 400 VAC 3G3EV--A4002--CE 3G3EV--A4002M--CE 3G3EV--A4002MA--CUE (S1)**
0,55 kW 1,8 A 3 x 400 VAC 3G3EV--A4004--CE 3G3EV--A4004M--CE 3G3EV--A4004MA--CUE (S1)**
1,1 kW 3,4 A 3 x 400 VAC 3G3EV--A4007--CE 3G3EV--A4007M--CE 3G3EV--A4007MA--CUE (S1)**
1,5 kW 4,8 A 3 x 400 VAC 3G3EV--A4015--CE 3G3EV--A4015M--CE 3G3EV--A4015MA--CUE (S1)**

* Differences in the connections (page 36) and in the set of parameters


On demand:
-- Input: 1 x 110 VAC
** -- Modbus in combination with 3G3EV--PJVOP485
-- CE and UL/CSA model with blind panel (without S1)
-- CE and UL/CSA model with digital operator (with S1)

Accessories

Input noise filter, braking resistors, ferrite rings

Rated output Rated voltage Product number


of inverter
Input noise filter Braking resistors Ferrite rings
(footprint type)
0,1 kW 1 x 230 VAC 3G3EV--PFI 1010--E(N) 3G3IV--PERF 150WJ401 3G3IV--PFO OC/1
0,2 kW
0,4 kW 1 x 230 VAC 3G3EV--PFI 1015--E(N) 3G3IV--PERF 150WJ201
0,75 kW
1,5 kW 1 x 230 VAC 3G3EV--PFI 1020--E(N) 3G3IV--PERF 150WJ101 3G3IV--PFO OC/2
0,2 kW 3 x 400 VAC 3G3EV--PFI 3006--E(N) 3G3EV--PERF 150WJ751 3G3IV--PFO OC/1
0,4 kW
0,75 kW
1,5 kW 3 x 400 VAC 3G3EV--PFI 3008--E(N) 3G3EV--PERF 150WJ401 3G3IV--PFO OC/2

Other

Description Product number


DIN bar adapter for assembly without line filter 3G3EV--PSPAT3 (0,1 -- 0,2 kW)
3G3EV--PSPAT4 (0,4 -- 0, 75 kW)
Blank cover for operating console 3G3EV--CVST
RS-232C interface instead of the programming console 3G3EV--PJVOP122A
RS-485 (modbus) adapter instead of the programming console 3G3EV--PJVOP485
Copy unit (save up to 3 sets of parameters in unit) 3G3EV--PJVOP125
Accessory: 3G3EV--PJVOP122A
3G3EV--PCN123

4
3G3EV inverter
Programming accessories

PC programming Description Cable length Product number


Programming software under WINDOWS -- SYSDRIVE Configurator

RS-232C interface -- 3G3EV--PJVOP122A


Connecting cable 1m 3G3EV--PCN122
3m 3G3EV--PCN323

Technical data

230 V Class

Single-phase: 3G3EV--AB_MA--CUE AB001 AB002 AB004 AB007 AB015

Three-phase: 3G3EV--A2_M--E A2001 A2002 A2004 A2007 A2015


Maximum allowed motor output kW 0,1 0,25 0,55 (0,4)* 1,1 (0,75)* 1,5 (1,1*)
Output data Inverter output kVA 0,3 0,6 1,1 1,9 2,6
Output rated current A 0,8 1,5 3,0 5,0 7,0
Max. output voltage three-phase proportional to the input voltage: 200 to 240 V
Output frequency 0,5...400 Hz
Supply Rated input voltage and single-phase: 200...240 V, 50/60 Hz
frequency three-phase: 200...230 V, 50/60 Hz
Max. voltage variation --15 % to +10 %
Max. frequency variation +5%
Weight kg 0,6 0,9 1,3 1,3 2,0

* with single phase connection for EV--A2 type

400 V Class

3G3EV--A4_MA--CUE, input: three-phase A4002 A4004 A4007 A4015


Maximum allowed motor output kW 0,37 0,55 1,1 1,5
Output data Inverter output kVA 0,9 1,4 2,6 3,7
Output rated current A 1,2 1,8 3,4 4,8
Max. output voltage three-phase proportional to the input voltage: 380 to 460 V
Output frequency 0,5...400 Hz
Supply Rated input voltage and three-phase: 380...460 V, 50/60 Hz
frequency
Max. voltage variation --15 % to +10 %
Max. frequency variation +5%
Weight kg 0,8 1,0 1,5 2,0

5
3G3EV inverter
Technical data (continued)

General details
Control functions Output frequency range 0,5...400 Hz
Frequency accuracy digital command : 0,01% at --10C to 50C
(temperature fluctuation) analogue command : 1% at 25C 10C
Digital inputs NPN/PNP switchable 24 VDC, 8 mA (terminal S1--S3)
Auxiliary voltage output 12 VDC, 20 mA (terminal FS)
Relay output 250 VAC/30 VDC, 1 A max. (terminal MA, MB, MC)
Overload capacity 150% of the output rated current for 1 minute
Frequency reference default 0...10 V = (20 kW ) or 4...20 mA (250 W )
Accelerating and braking 0...999 s (values can be set separately for acceleration and braking ramp)
times
Braking torque approximately 20% (with braking resistor: 125% to 220%) continuously
Protective Stall prevention Stall prevention during the acceleration and braking phase, and also at assigned
functions frequency can be programmed separately
Instantaneous overcurrent when 250% of the rated output current is exceeded, the motor coasts to stop
Overload at 150% of the rated output current the motor runs down to a halt after 1 minute
Earth fault via electronic circuit
Protection against motor electronic thermal protection against overload
overload
Ambient conditions Type of protection IP20
Cooling self-cooling
Operating temperature --10C to +50C (without frozen-fog formation)
Humidity 90% rel. humidity (without condensation)

Modbus model (3G3EV--A_MA--CUE)*


Communication modbus protocol
Speed 19,2 kbps
Number of slaves 32 max.
Transmission transposed 2 wire lead, RS-485

* can only be used in connection with the 3G3EV--PJVOP485 adapter

6
3G3EV inverter
Technical data (continued)

Standard model Multifunction model (modbus)


Number of defined inputs 2 2
Number of free programmable inputs 1 3
Programmable three-wire sequence NO YES
with:
fault reset NO YES
external fault NO A or B contact optional
multifunction frequency max. 2 max. 8
2 prog. ramp times NO YES
external controller block NO A or B contact optional
choice of operating mode NO YES
order for blocking accel/braking NO YES
UP/DOWN function NO YES
REMOTE/LOCAL-- NO YES
switching function
JOG speed (creeping) NO YES
Relay output 1a, 1b contact 1a, 1b contact
(AC: 250 V, 1 A / DC: 30 V, 1 A) (AC: 250 V, 1 A / DC: 30 V, 1 A)
Programmable opto-coupler output 0 1
Programmable fault YES YES
with:
motor runs YES YES
fref = factual NO YES
zero speed NO YES
speed change NO YES
excess torque NO YES
controller block NO YES
insufficient voltage NO YES
speed search NO YES
Automatic new start NO max. 10 repeats
Output frequency limitation NO YES
Jump frequency NO max. 3 positions
Block for reverse turning direction NO YES
DC braking on braking on starting and braking
Slip compensation NO YES
Frequency reference value and amplification offset YES YES
Display (operator) Fref, Fout, output current, fault Fref, Fout, output current, fault
Forward/Reverse display (operator) initialised with LED initialised with LED
Analogue output monitor NO DC, 0 to 10 V (Fout or Iout)
Torque performance 150% from 1,5 Hz 150% from 1,5 Hz
Noise extremely quiet extremely quiet

7
3G3EV inverter
Connections diagram

Standard design
3G3EV--A_--CE
Voltage supply Braking resistor
With single-phase models L3 remains free. 200...240 VAC, 50/60 Hz or (optional)
380...460 VAC, 50/60 Hz
three-phase
Line filter B1 B2

L1(R) U
L2/N (S) V M
L3 (T) W

Forwards--Start/--Stop Multifunction
SF relay output
Reverse--Start/--Stop MA
Closer
SR
Multifunction input MB
Opener
S1
MC
Common contact
SC

for frequency reference FS


value (4...20 mA) (+12 VDC)
SW1--switch position I FR
0...10 V, 4...20 mA
FC E

Multifunction design
3G3EV--A_M--CE
Voltage supply Braking resistor
With single-phase models L3 remains free. 200...240 VAC, 50/60 Hz or (optional)
380...460 VAC, 50/60 Hz
three-phase
Line filter B1 B2

L1(R) U
L2/N (S) V M
L3 (T) W

AM
Multifunction
Forwards--Start/--Stop analog output
SF 0...10 VDC
Reverse--Start/--Stop
SR 0V
Multifunction input 1 Multifunction
S1 relay output
MA
Multifunction input 2 Multifunction contact output
S2 (contact a)
MB
Multifunction input 3 contact b
S3
MC
Common
SC
PA
Multifunction
output
PC
48 VDC, 50 mA
for frequency reference FS
value (4...20 mA) (+12 VDC)
SW1--switch position I FR
0...10 V, 4...20 mA
FC E

8
3G3EV inverter
Connections diagram (continued)

Modbus design
3G3EV--A_MA--CUE with 3G3EV--PJVOP485
Voltage supply Braking resistor
With single-phase models L3 remains free. 200...240 VAC, 50/60 Hz or (optional)
380...460 VAC, 50/60 Hz
three-phase
Line filter B1 B2

L1(R) U
L2/N (S) V M
L3 (T) W

AM
Multifunction
Forwards--Start/--Stop analog output
SF 0...10 VDC
Reverse--Start/--Stop
SR 0V
Multifunction input 1 Multifunction
S1 relay output
MA
Multifunction input 2 Multifunction contact output
S2 (contact a)
MB
Multifunction input 3 contact b
S3
MC
Common
SC
PA
Multifunction
3G3EV--PJVOP485 output
(Modbus protocol)
PC
1 S/R -- 48 VDC, 50 mA

2 SR +
3 SGND
4 S/R--
5 S/R+

for frequency reference FS


value (4...20 mA) (+12 VDC)
SW1--switch position I FR
0...10 V, 4...20 mA
FC E

9
3G3EV inverter
Technical documentation

English Product Title Product number


documentation
Standard type User Manual I011--E1--1A

SYSDRIVE INVERTER Multifunction Type User Manual I013--E1--2

Multifunction MA-CUE type User Manual I013--E2--1

OPERATION MANUAL

Dimensions (mm)

3G3EV--AB_

B B1 T T1 Dia- Product
gram number
68 56 75 3 1 001
68 56 108 5 1 002
108 96 130 -- 2 004
118 128
108 96 130 -- 2 007
130 118 170 -- 2 015

T1
B1

B T

Diagram 1

10
3G3EV inverter
Dimensions (mm) (continued)

3G3EV--A4_

B B1 T T1 Dia- Product
gram number
108 96 83 8 2 002
108 96 110 5 2 004
108 96 140 5 2 007
118 128
130 118 170 5 2 015

3G3EV--A2_

B B1 T T1 Dia- Product
gram number T1
B1
68 56 75 3 1 001
B T
68 56 88 3 1 002
68 56 110 5 1 004
96 130 -- 2
Diagram 2
108 007
108 96 155 -- 2 015

Line filter 3G3EV--PFI_

B B1 H H1 T Product
number
72 51 162 149 41 1010E(N)
111 91 162 149 41 1015E(N)
134 91 162 148 42 1020E(N)
112 91 162 148 42 3006E(N) H1 H

134 91 162 148 42 3008E(N)

B1

B T

11
3G3EV inverter

12
3G3JV inverter
General

The 3G3JV is a miniature high--efficiency frequency inverter with an


excellent price-- performance relationship.
The generous dimensions of the power section ensure a high starting
torque and low susceptibility to overload which increases machine
reliability.
Its many programmable inputs and outputs, an integrated potentio-
meter for speed control and various monitor functions provide the
inverter with high versatility and flexibility. The multifuntion inputs can
be set to either PNP or NPN. The analog inputs can be 0..10 V,
4..20 mA or 0..20 mA.
Features
-- exceptionally compact design
-- integrated reference value potentiometer
-- modbus interface, optional
-- 8 fixed frequencies
-- 4 multifunction digital inputs
-- 1 multifunction digital output
-- 1 multifunction analog output
-- Approval: CE, UL, CSA

System architecture

To comply with relevant EMC guidelines it is imperative for


frequency inverters to be operated with line filters.

Cabinet assembly
on metal plate
Voltage Contact surfaces to
supply Shielding the metal plate
L1
L2
L3
PE

Line filter,
footprint type

Shielding
U
V M
W
PE

13
3G3JV inverter
Product overview

Max. motor Output Rated Product number


output current voltage
Standard type

Single phase 230 V


0,1 kW 0,8 A 1 x 230 VAC 3G3JV--AB001
0,25 kW 1,6 A 1 x 230 VAC 3G3JV--AB002
0,55 kW 3,0 A 1 x 230 VAC 3G3JV--AB004
1,1 kW 5,0 A 1 x 230 VAC 3G3JV--AB007
1,5 kW 8,0 A 1 x 230 VAC 3G3JV--AB015
Three phase 230 V

0,1 kW 0,8 A 3 x 230 VAC 3G3JV--A2001


0,25 kW 1,6 A 3 x 230 VAC 3G3JV--A2002
0,55 kW 3,0 A 3 x 230 VAC 3G3JV--A2004
1,1 kW 5,0 A 3 x 230 VAC 3G3JV--A2007
1,5 kW 8,0 A 3 x 230 VAC 3G3JV--A2015
2,2 kW 11 A 3 x 230 VAC 3G3JV--A2022
4,0 kW 11 A 3 x 230 VAC 3G3JV--A2040
Three phase 400 V

0,37 kW 1,2 A 3 x 400 VAC 3G3JV--A4002


0,55 kW 1,8 A 3 x 400 VAC 3G3JV--A4004
1,1 kW 3,4 A 3 x 400 VAC 3G3JV--A4007
1,5 kW 4,8 A 3 x 400 VAC 3G3JV--A4015
2,2 kW 5,5 A 3 x 400 VAC 3G3JV--A4022
3,0 kW 7,2 A 3 x 400 VAC 3G3JV--A4030
4,0 kW 9,2 A 3 x 400 VAC 3G3JV--A4040

Accessories

Line filter, braking resistors, ferrite rings, DIN track mounting bracket
Inverter Product number
Line filter (footprint filter) Ferrite rings DIN track mounting bracket
3G3JV--AB001 3G3JV--PFI1010--E 3G3IV--PFO OC/1 3G3IV--PZZ08122A
3G3JV--AB002 3G3JV--PFI1010--E 3G3IV--PFO OC/1 3G3IV--PZZ08122A
3G3JV--AB004 3G3JV--PFI1010--E 3G3IV--PFO OC/1 3G3IV--PZZ08122A
3G3JV--AB007 3G3JV--PFI1020--E 3G3IV--PFO OC/1 3G3IV--PZZ08122B
3G3JV--AB015 3G3JV--PFI1020--E 3G3IV--PFO OC/2 3G3IV--PZZ08122B
3G3JV--A2001 3G3JV--PFI2010--E 3G3IV--PFO OC/1 3G3IV--PZZ08122A
3G3JV--A2002 3G3JV--PFI2010--E 3G3IV--PFO OC/1 3G3IV--PZZ08122A
3G3JV--A2004 3G3JV--PFI2010--E 3G3IV--PFO OC/1 3G3IV--PZZ08122A
3G3JV--A2007 3G3JV--PFI2010--E 3G3IV--PFO OC/1 3G3IV--PZZ08122A
3G3JV--A2015 3G3JV--PFI2020--E 3G3IV--PFO OC/2 3G3IV--PZZ08122B
3G3JV--A2022 3G3JV--PFI2020--E 3G3IV--PFO OC/2 3G3IV--PZZ08122B
3G3JV--A2040 3G3JV--PFI2030--E 3G3IV--PFO OC/2 3G3IV--PZZ08122C
3G3JV--A4002 3G3JV--PFI3005--E 3G3IV--PFO OC/1 3G3IV--PZZ08122B
3G3JV--A4004 3G3JV--PFI3005--E 3G3IV--PFO OC/1 3G3IV--PZZ08122B
3G3JV--A4007 3G3JV--PFI3010--E 3G3IV--PFO OC/1 3G3IV--PZZ08122B
3G3JV--A4015 3G3JV--PFI3010--E 3G3IV--PFO OC/2 3G3IV--PZZ08122B
3G3JV--A4022 3G3JV--PFI3010--E 3G3IV--PFO OC/2 3G3IV--PZZ08122B
3G3JV--A4030 3G3JV--PFI3020--E 3G3IV--PFO OC/2 3G3IV--PZZ08122C
3G3JV--A4040 3G3JV--PFI3020--E 3G3IV--PFO OC/2 3G3IV--PZZ08122C

14
3G3JV inverter
Technical data

230 V class

Single phase: 3G3JV--AB AB001 AB002 AB004 AB007 AB015

Three phase: 3G3JV--A2 A2001 A2002 A2004 A2007 A2015 A2022 A2040
Maximum allowed motor output kW 0,12 0,25 0,55 1,1 1,5 (1,1*) 2,2 4,0
(0,4*) (0,75*)
Output data Inverter output kVA 0,3 0,6 1,1 1,9 3,0 4,2 6,7
Output rated current A 0,8 1,6 3,0 5,0 8,0 11,0 17,5
Max. output voltage proportional to the input voltage: 0..240 V
Output frequencies 400 Hz
Supply Rated input voltage and 200..240 V, 50/60 Hz
frequency
Max. voltage variation --15 % to +10 %
Max. frequency variation +5%

* With single phase connection for JV--A2 type s

400 V class

Three phase: 3G3JV--A4 A4002 A4004 A4007 A4015 A4022 A4030 A4040
Maximum allowed motor output kW 0,37 0,55 1,1 1,5 2,2 3,0 4,0
Output data Inverter output kVA 0,9 1,4 2,6 3,7 4,2 5,5 7,0
Output rated current A 1,2 1,8 3,4 4,8 5,5 7,2 9,2
Max. output voltage proportional to the input voltage: 0..460 V
Output frequencies 400 Hz
Supply Rated input voltage and 3--phase, 380..460 V, 50/60 Hz
frequency
Max. voltage variation --15 % to +10 %
Max. frequency variation + /- 5 %

* With single phase connection for JV--A2 type s

15
3G3JV inverter
Technical data (continued)
General data
Control functions Control method Sinusoidal PWM, terminal Volts/Hertz control
Output frequency range 0,1..400 Hz
Frequency precision digital reference value: 0,01 % (--10..+50C)
analogue reference value: 0,5% (25 10C)
Resolution of frequency digital reference value: 0,01 Hz (<100 Hz), 0.1 Hz (>100 Hz)
reference value analogue reference value 1/1000 of maximum frequency
Resolution of output frequency 0,01 Hz
Overload capacity 150%/60 s
Frequency reference value 0..10 V (20 kW ), 4--20 mA (250 W ), 0--20 mA (250 W )
Braking torque up to 200 W 150%
(short--time peaks) 550W, 1,1 kW 100%
1,5 kW 50%
>1,5 kW 20%
Sustained braking torque approx. 20% without, 150% with external braking resistor
Protective Motor overload protection electronically adjustable motor protection
functions Instantaneous overcurrent stops at approx. 250% of rated output current
protection
Overload protection stops at 150% of rated current for 1 min.
Overvoltage protection stops when maincircuit DC voltage is approx. 410 V
Undervoltage protection stops when maincircuit DC voltage is approx. 160 V
Momentary power interruption stops for 15 ms or more by setting the inverter to momentary power interruption mode,
compensation (selection) operation can be continued if power is restored within approx. 0,5 sec.
Cooling fin overheating detects at 110 C 10 C
Ventilator control electronic protection against blocking
Grounding protection protection at rated output current level
Functions Digital inputs 4 multifunction digital input
Digital outputs 1 multifunction digital output
Analog output 1 multifunction analog output (0..10 V)
Braking and acceleration 0,0..999 s
times
Display frequency, current or reference value by selection
error and status LED
Ambient conditions Type of protection IP20, wall installation
Cooling separate cooler for 0,75 kW (200 V)
Ambient temperature open installation: --10C to 50C
wall installation: --10C to 40C
Air humidity 95% (without condensation)
Storage temperature --20C to +60C
Assembly in cabinet, free of dust and corrosive gases
Position height max. 1000 m
Ambient conditions Vibration resistance 1 g at <20 Hz, 0,2 g at <50 Hz

16
3G3JV inverter
Connections diagram

L3 remains free with single--phase equipment

Voltage supply
200...240 VAC, 50/60 Hz,
single--phase

Line filter
L1(R) U
L2/N (S) V M
W
E

AM
Forwards--Start--Stop Multifunction
S1 analog output
Multifunction input 1 0..10 VDC
S2 AC
Multifunction input 2 0V
S3 Multifunction
relay output
Multifunction input 3 MA
S4 Closer
Multifunction input 4 MB
S5 Opener

Reference potential MC
Multifunction inputs Common contact

FS
(+12 VDC)
Frequency reference FR
value 0..10 V, 4..20 mA
FC

17
3G3JV inverter
Dimensions (mm)

3G3JV

Product number

B B1 T AB A2
68 56 70 001 001
68 56 70 002 002
68 56 112 004 004 118 128

68 56 112 -- 007
108 96 129 007 015
108 96 154 015 022
140 128 161 -- 040 8,5
B1

B T

Product
number

B B1 T A4
108 96 81 002
108 96 99 004
108 96 129 007
108 96 154 015
108 96 154 022
140 128 161 030
140 128 161 040

Line filter 3G3JV--PFI_

B B1 H H1 T Product
number
71 51 169 156 45 1010E
111 91 169 156 50 1020E
82 62 194 181 50 2010E
111 91 169 156 50 2020E H1 H

144 120 174 161 50 2030E


111 91 169 156 50 3005E
111 91 169 156 50 3010E
144 120 174 161 50 3020E B1

B T

18
3G3JV inverter
Set of Parameters

Parameter Default MODBUS Name Adjustment range


number setting address

n001 1 101H Parameter write prohibit selection/ 0 Only n01 can be adjusted
parameter initialization 1 n01--079 can be altered
6 reset error memory
7 not used
8 initializes parameters to default values in 2--wire sequence
9 initializes parameters to default values in 3--wire sequence
n002 0 102H Operation mode selection 0 Operator console
1 Multifunction inputs
2 via modbus (option card needed)
n003 0 103H Frequency reference selection 0 integrated potentiometer
1 parameter n021
2 0..10 V
3 4..20 mA
4 0..20 mA
6 modbus (option card needed)
n004 0 104H Stop method 0 Stop at ramp (n017)
1 Coast to stop
n005 0 105H Backwards direction of rotation 0 Reverse enabled
1 Reverse disabled
n006 0 106H Operator stop button 0 Stop button at n02= 1 enabled
1 Stop button at n02= 1 disabled
n007 0 107H Reference value in local mode 0 integrated potentiometer
1 digital via operator (n024)
n008 0 108H Reference value input in 0 complete input with ENTER
local mode 1 no ENTER necessary
n009 60.0 Hz 109H Maximum output frequency 50,0..400 Hz

n010 200 V 10AH Max. output voltage 1..255 V


n011 60.0 Hz 10BH Corner frequency 0,2..400 Hz
n012 1.5 Hz 10CH Middle output frequency 0,1..399,9 Hz
n013 12 V 10DH Output voltage at middle output 0,1..255 V
frequency
n014 1.5 Hz 10EH Minimum output frequency 0,1..10 Hz
n015 12 V 10FH Output voltage at minimum output 0.1..50 V
frequency
n016 10.0s 110H Acceleration time 1 0,0..999 s

19
3G3JV inverter
Set of parameters (continued)

Parameter Default MODBUS Name Adjustment range


number setting address

n017 10.0s 111H Braking time 1 0,0..999 s


n018 10.0s 112H Acceleration time 2 0,0..999 s
n019 10.0s 113H Braking time 2 0,0..999 s
n020 0 114H S curve slide on braking/ 0 no S curve
accelerating 1 0,2 s
2 0,5 s
3 1,0 s
n021 0.00 Hz 115H Frequency reference value 1 0,0..400 Hz
n022 0.00 Hz 116H Frequency reference value 2 0,0..400 Hz
n023 0.00 Hz 117H Frequency reference value 3 0,0..400 Hz
n024 0.00 Hz 118H Frequency reference value 4 0,0..400 Hz
n025 0.00 Hz 119H Frequency reference value 5 0,0..400 Hz
n026 0.00 Hz 11AH Frequency reference value 6 0,0..400 Hz
n027 0.00 Hz 11BH Frequency reference value 7 0,0..400 Hz
n028 0.00 Hz 11CH Frequency reference value 8 0,0..400 Hz
n029 6.00 Hz 11DH Jog frequency 0,0..400 Hz
n030 100% 11EH Max. reference value limit 0..110 % of n09
n031 0 11FH Min. reference value limit 0..110 % of n09
n032 depending on 120H Motor rated current for simulation 0..120% in relation to inverter rated current
model of motor protection switch
n033 0 121H Simulation of motor protection 0 Standard motor with standard rated data
switch 1 Standard motor for short--time operation
2 No thermal protection
n034 8min 122H Thermal motor time constant 1 -- 60min
n035 0 123H Function of ventilator 0 only runs during RUN (1 min after STOP)
(in the inverter) 1 always runs
n036 2 124H Multifunction input 2 2 reverse/stop (2--wire)
3 external error (NO)
4 external error (NC)
5 Error reset
6 Multi--step speed reference 1
7 Multi--step speed reference 2
8 Multi--step speed reference 3
10 Jogging
11 Acc./dec. time change over
12 external base block (NO)
13 external base block (NC)
14 Speed search of max. frequency
15 Speed search of assigned frequency
16 Acc./dec. prohibit
17 Local/Remote change--over
18 Serial change--over/operator
19 Fast stop n19 error (NO)
20 Fast stop n19 alarm (NO)
21 Fast stop n19 error (NC)
22 Fast stop n19 alarm (NC)
n037 5 125H Multifunction input 3 0 Change in rotation direction (3--wire) otherwise see n036
n038 3 126H Multifunction input 4 see n036
n039 6 127H Multifunction input 5 34 Up or down comment
35 Self--test otherwise see n036

20
3G3JV inverter
Set of Parameters (continued)

Parameter Default MODBUS Name Adjustment range


number setting address

n040 1 128H Multifunction output 0 Fault


MA, MB, MC (relay) 1 Inverter in operation
2 Reference value reached
3 Zero frequency reached
4 Output frequency n058
5 Output frequency n058
6 Over--torque (NO)
7 Over--torque (NC)
10 Alarm
11 Base block
12 Run mode
13 Ready for operation
14 active during error reset
15 under--voltage recognised
16 Reverse direction
17 Speed search
18 Data transfer via ModBus
n041 100% 129H Reinforcement of analog input 0..255%
n042 0% 12AH Offset of analog input --99..99%
n043 0.1s 12BH Filter time for analog input 0.00..2.00s
n044 0 12CH Analog input holding 0 Output frequency
1 Motor current
n045 1 12DH Analog input reinforcement 0,00..2,00
n046 4 12EH Clock frequency 1 2,5 kHz
2 5,0 kHz
3 7,5 kHz
4 10 kHz
7 12 x motor frequency
8 24 x motor frequency
9 36 x motor frequency
n047 0 12FH Operation after short voltage 0 Error signal
breakdown 1 Error signal after >0.5 s
2 Operation is continued
n048 0 130H New start attempts after error 0..10
n049 0.0 Hz 131H Gating frequency 1 0,0..400 Hz
n050 0.0 Hz 132H Gating frequency 2 0,0..400 Hz
n051 0.0 Hz 133H Bandwidth of gating frequencies 0,0..25,5 Hz
n052 50% 134H Current for d.c. braking 0..100 % of the inverter rated current

n053 0.5s 135H d.c. braking time at Stop 0,0..25,5 s


n054 0.5s 136H d.c. braking time at Start 0,0..25,5 s
n055 0 137H Protection against sweep on 0 Enabled
braking 1 Disabled (braking resistor!!)
n056 170% 138H Level of protection against sweep 30..200% of the rated current
on accelerating
n057 160% 139H Level of protection against sweep 30..200% of the rated current
during operation
n058 0.0 Hz 13AH Frequency recognition level 0,0..400 Hz
n059 0 13BH Over--torque recognition 0 Disabled
1 Detection only when speed coincides
and operation continues
2 Detection only when speed coincides
and output shut off
3 Always detection, issues alarm
4 Always detection, output shut off

21
3G3JV inverter
Set of Parameters (continued)

Parameter Default MODBUS Name Adjustment range


number setting address

n060 160% 13CH Level of torque recognition 30..200%


n061 0.1s 13DH Time of torque recognition 0,1..10 s
n062 0 13EH Storing of reference value during 0 No stored after STOP
motor poti operation 1 Stored after STOP
n063 1.0 13FH Torque boost 0,0..2,5
n064 depending on 140H Rated slip 0,0..20.0 Hz
model
n065 depending on 141H no--load current 0..99%
model
n066 0.0 142H Slip compensation reinforcement 0,0..2.5
n067 2.0s 143H Delay time for slip compensation 0,0..25,5 s
n068 0 144H Slip compensation on braking 0 Disabled
1 Enabled
n069 0 145H Setting unit of transmission fre- 0 0,1 Hz
quence reference / frequency 1 0,01 Hz
monitor 2 30000 = max. frequency
3 0,1 %
n070 0 146H Slave address 0..1
n071 2 147H Baud rate 0 2400 Kbaud
1 4800 Kbaud
2 9600 Kbaud
3 19200 Kbaud
n072 0 148H Parity 0 straight
1 not straight
2 no parity
n073 10ms 149H Send waiting time 10..65 ms
n074 0 14AH RTS control 0 RTS control
1 RS422A, 1:1 link
n075 0 14BH Low speed carrier frequency re- 0 Function disabled
duction 1 Function enabled
n077 0 14DH Select to prevent accidently over- 0 Read prohibited
writing constants stored in EE- 1 Read allowed
PROM or digital operator
n078 14EH Error memory
n079 14FH Software number

22
3G3MV inverter
General

The 3G3MV is a miniature frequency inverter incorperating an open


loop vector control function, which ensures a torque output that is
150% of the rated motor torque at an output frequency of 1Hz.
Furthermore, the 3G3MV suppresses the revolution fluctuation caused
by the load.

Incorporates a high--speed current limit function, thus suppressing


overcurrent caused by high torque and ensuring smooth operation of
the motor.

Flexibility is an important feature: the reference value default is


selected through 4..20 mA, 0..10 V or a pulse train that is speed
proportional in its frequency. The multi--function inputs can be set to
either PNP or NPN. Plug--in are available for different options.

Features
-- exceptionally compact design
-- integrated reference value potentiometer
-- integrated modbus interface
-- optional field bus cards
(I.E. DeviceNet)
-- 16 fixed frequencies
-- 6 multifunction digital inputs
-- 3 multifunctional digital outputs
-- 1 multifunctional analog output
-- 1 multifunctional analog input
-- Approval: CE, UL, CSA

System architecture

To comply with relevant EMC guidelines it is imperative for


frequency inverters to be operated with line filters.

Cabinet assembly on
metal plate
Voltage Contact surfaces to
supply Shielding the metal plate
L1
L2
L3
PE

Line filter, footprint type

Shielding
U
V M
W
PE

23
3G3MV inverter
Product overview

Max. motor output Output current Product number

Single phase 230 V


0,12 kW 0,8 A 3G3MV--AB001
0,25 kW 1,6 A 3G3MV--AB002
0,55 kW 3,0 A 3G3MV--AB004
1,1 kW 5,0 A 3G3MV--AB007
1,5 kW 7,0 A 3G3MV--AB015
2,2 kW 11 A 3G3MV--AB022
4,0 kW 17,5 A 3G3MV--AB040

Three--phase 230 V
0,12 kW 0,8 A 3G3MV--A2001
0,25 kW 1,6 A 3G3MV--A2002
0,55 kW 3,0 A 3G3MV--A2004
1,1 kW 5,0 A 3G3MV--A2007
1,5 kW 7,0 A 3G3MV--A2015
2,2 kW 11 A 3G3MV--A2022
4,0 kW 17,5 A 3G3MV--A2040
5,5 kW 25 A 3G3MV--A2055
7,5 kW 33 A 3G3MV--A2075

Three--phase 400 V
0,25 kW 1,2 A 3G3MV--A4002
0,55 kW 1,8 A 3G3MV--A4004
1,1 kW 3,4 A 3G3MV--A4007
1,5 kW 4,8 A 3G3MV--A4015
2,2 kW 5,5 A 3G3MV--A4022
3,0 kW 7,2 A 3G3MV--A4030
4,0 kW 9,2 A 3G3MV--A4040
5,5 kW 14,8 A 3G3MV--A4055
7,5 kW 18 A 3G3MV--A4075

24
3G3MV inverter
Accessories

Line filter, braking resistors, ferrite rings, DIN track mounting bracket

Inverter Product number


Line filter Braking resistors Ferrite rings DIN track mounting
(mountable under- bracket
neath)
3G3MV--AB001 3G3MV--PFI1010--E 3G3IV--PERF150WJ401 3G3IV--PFO OC/1 3G3IV--PZZ08122A
3G3MV--AB002 3G3MV--PFI1010--E 3G3IV--PERF150WJ401 3G3IV--PFO OC/1 3G3IV--PZZ08122A
3G3MV--AB004 3G3MV--PFI1010--E 3G3IV--PERF150WJ201 3G3IV--PFO OC/1 3G3IV--PZZ08122A
3G3MV--AB007 3G3MV--PFI1020--E 3G3IV--PERF150WJ201 3G3IV--PFO OC/1 3G3IV--PZZ08122B
3G3MV--AB015 3G3MV--PFI1020--E 3G3IV--PERF150WJ101 3G3IV--PFO OC/2 3G3IV--PZZ08122B
3G3MV--AB022 3G3MV--PFI1030--E 3G3IV--PERF150WJ700 3G3IV--PFO OC/2 3G3IV--PZZ08122C
3G3MV--AB040 3G3MV--PFI1040--E 3G3IV--PERF150WJ620 3G3IV--PFO OC/2 3G3IV--PZZ08122D
3G3MV--A2001 3G3MV--PFI2010--E 3G3IV--PERF150WJ401 3G3IV--PFO OC/1 3G3IV--PZZ08122A
3G3MV--A2002 3G3MV--PFI2010--E 3G3IV--PERF150WJ401 3G3IV--PFO OC/1 3G3IV--PZZ08122A
3G3MV--A2004 3G3MV--PFI2010--E 3G3IV--PERF150WJ201 3G3IV--PFO OC/1 3G3IV--PZZ08122A
3G3MV--A2007 3G3MV--PFI2010--E 3G3IV--PERF150WJ201 3G3IV--PFO OC/1 3G3IV--PZZ08122B
3G3MV--A2015 3G3MV--PFI2020--E 3G3IV--PERF150WJ101 3G3IV--PFO OC/2 3G3IV--PZZ08122B
3G3MV--A2022 3G3MV--PFI2020--E 3G3IV--PERF150WJ700 3G3IV--PFO OC/2 3G3IV--PZZ08122C
3G3MV--A2040 3G3MV--PFI2030--E 3G3IV--PERF150WJ620 3G3IV--PFO OC/2 3G3IV--PZZ08122C
3G3MV--A2055 3G3MV--PFI2050--E 3G3IV--PERF500WJ360T 3G3IV--PFO OC/2 --
3G3MV--A2075 3G3MV--PFI2050--E 3G3IV--PERF101WJ360T 3G3IV--PFO OC/2 --
3G3MV--A4002 3G3MV--PFI3005--E 3G3IV--PERF150WJ751 3G3IV--PFO OC/1 3G3IV--PZZ08122B
3G3MV--A4004 3G3MV--PFI3005--E 3G3IV--PERF150WJ751 3G3IV--PFO OC/1 3G3IV--PZZ08122B
3G3MV--A4007 3G3MV--PFI3010--E 3G3IV--PERF150WJ751 3G3IV--PFO OC/2 3G3IV--PZZ08122B
3G3MV--A4015 3G3MV--PFI3010--E 3G3IV--PERF150WJ401 3G3IV--PFO OC/2 3G3IV--PZZ08122B
3G3MV--A4022 3G3MV--PFI3010--E 3G3IV--PERF150WJ201 3G3IV--PFO OC/2 3G3IV--PZZ08122B
3G3MV--A4030 3G3MV--PFI3020--E 3G3IV--PERF150WJ201 3G3IV--PFO OC/2 3G3IV--PZZ08122C
3G3MV--A4040 3G3MV--PFI3020--E 3G3IV--PERF150WJ101 3G3IV--PFO OC/2 3G3IV--PZZ08122C
3G3MV--A4055 3G3MV--PFI3030--E 3G3IV--PERF500WJ360T 3G3IV--PFO OC/2 --
3G3MV--A4075 3G3MV--PFI3030--E 3G3IV--PERF101WJ360T 3G3IV--PFO OC/2 --

Miscellaneous

Description Product number


Multi function analog input cable 3G3MV--PCN--CN2

25
3G3MV inverter
Accessories (continued)
Miscellaneous

Description Product number


Option card holder on demand

Option cards on demand


-- CAN--Bus
-- DeviceNet
-- Interbus S
-- PROFIBUS DP

Technical data

230 V class

Single phase: 3G3MV--AB AB001 AB002 AB004 AB007 AB015 AB022 AB040

Three phase: 3G3MV--A2 A2001 A2002 A2004 A2007 A2015 A2022 A2040 A2055 A2075
Maximum allowed motor output kW 0,12 0,25 0,55 1,1 1,5 2,2 4,0 5,5 7,5
(0,4*) (0,75*) (1,1*)
Output data Inverter output kVA 0,3 0,6 1,1 1,9 3,0 4,2 6,7 9,5 13,0
Output rated current A 0,8 1,6 3,0 5,0 8,0 11,0 17,5 25,0 33,0
Max. output voltage proportional to the input voltage: 0..240 V
Output frequencies 400 Hz
Supply Rated input voltage 200..240 V, 50/60 Hz
and
frequency
Max. voltage variation --15 % to +10 %
Max. frequency varia- +5%
tion
Weight A2/AB type kg 0,6/0,6 0,6/0,7 0,9/1,0 1,1/1,5 1,4/1,5 1,5/2,2 2,1/2,9 4,6 4,8

400 V class

Three phase, 3G3MV--A4 A4002 A4004 A4007 A4015 A4022 A4030 A4040 A4055 A4075
Maximum allowed motor output kW 0,25 0,55 1,1 1,5 2,2 3,0 4,0 5,5 7,5
Output data Inverter output kVA 0,9 1,4 2,6 3,7 4,2 5,5 7,0 11,0 14,0
Output rated current A 1,2 1,8 3,4 4,8 5,5 7,2 9,2 14,8 18,0
Max. output voltage proportional to the input voltage: 4..400 V
Output frequencies 400 Hz
Supply Rated input voltage 380..460 V, 50/60 Hz
and
frequency
Max. voltage variation --15 % to +10 %
Max. frequency vari- +5%
ation
Weight kg 1,0 1,1 1,5 1,5 1,5 2,1 2,1 4,8 4,8

* With single phase connection for MV--A2 type.

26
3G3MV inverter
Technical data (continued)

General data
Control functions Control method Sinusoidal PWM, can be switched between v/f control and voltage vector control
Output frequency range 0,1..400 Hz
Frequency precision digital reference value: 0,01 % (--10..+50C)
analog reference value: 0,5% (25 10C)
Resolution of frequency digital reference value: 0,01 Hz (<100 Hz), 0.1 Hz (>100 Hz)
reference value analog reference value 1/1000 of maximum frequency
Resolution of output frequency 0,01 Hz
Overload capacity 150%/60 s
Frequency reference value 0..10 V (20 kW ), 4--20 mA (250 W ), 0--20 mA (250 W )
pulse signal
Braking torque up to 200 W 150%
(short--time peaks) 550W, 1,1 kW 100%
1,5 kW 50%
>1,5 kW 20%
Sustained braking torque approx. 20% without, 150% with external braking resistor
Protective Motor overload protection electronically adjustable motor protection
functions Instantaneous overcurrent stops at approx: 250% of rated output current
protection
Overload protection stops at 150% of rated current for 1 min.
Overvoltage protection stops when main circuit DC voltage is approx 410 V
Undervoltage protection stops when main circuit DC voltage is approx 160 V
Momentary power interruption stops for 15 ms or more by setting the inverter to momentary power interruption mode,
compensation selection operation can be continued if power is restored within approx 0.5 sec.
Cooling fin overheating electronic protection
Ventilator control electronic protection against blocking
Grounding protection protection of rated output current
Functions Digital inputs 7 multifunction digital input
Digital outputs 1 relay output, 2 open collector outputs, multifunction
Analog input 1 multifunction analog input
Analog output 1 multifunction analog output
Braking and acceleration 0,01..6000 s
times
Display frequency, current or reference value by selection
error and status LED
Ambient conditions Type of protection IP20, wall installation
Cooling separate cooler for 0,75 kW (200 V), 1,5 kW (400 V)
Ambient temperature open installation: --10C to 50C
wall installation: --10C to 40C
Air humidity 95% (without condensation)
Storage temperature --20C to +60C
Assembly cabinet, free of dust and corrosive gases
Position height 1000 mA
Vibration resistance 1 g at <20 Hz, 0,2 g at <50 Hz

27
3G3MV inverter
Connections diagram

(Connect L2/L3 with single--phase equipment)

Line Line con-


fuse tactor Line filter
R/L1 U
S/L2 V M
T/L3 W
3--phase

Multifunction input 1
S1
Multifunction analog output/
Multifunction input 2
S2 AM pulse monitor ouput 0..10 V
Multifunction input 3
S3
Multifunction input 4 Analog output
S4 AC 0V
Multifunction input 5
S5
Multifunction input 6
S6
Multifunction relay
Multifunction input 7 MA
S7 Closer
Reference potential SC MB
Multifunction inputs Opener
MC
Common contact

P1 Multifunction output 1
Pulse reference value RP
open collector
+12 V, 20 mA FS
P2
Analog reference value FR Multifunction output 2
PC open collector

17
Reference potential 0V
set--point value
33

40 (R+)
E
41 (R--)
Modbus interface
RS422/RS485 42 (S+)
43 (S--)

Connector
Digital Operator
Multifunction analog voltage input 1
Multifunction analog current input
2 CN2
Analog input common 3

28
3G3MV inverter
Dimensions (mm)

3G3MV--AB_

B B1 T H Product
number
68 56 76 128 001
68 56 89 128 002
118 H
68 56 138 128 004
108 96 140 128 007
108 96 156 128 015
140 128 163 128 022
158 180 128 8,5
170 040 B1

B T

3G3MV--A2_

B B1 T H Product
number
68 56 76 128 001
68 56 76 128 002
68 56 108 128 004
68 56 128 128 007
108 96 131 128 015
108 96 140 128 022
140 128 143 128 040
180 164 170 260 055
180 164 170 260 075

3G3MV--A4_

B B1 T H Product
number
108 96 92 128 002
108 96 110 128 004
108 96 140 128 007
108 96 156 128 015
108 96 156 128 022
140 128 143 128 030
140 128 143 128 040
180 164 170 260 055
180 164 170 260 075

29
3G3MV inverter
Line filter 3G3MV--PFI_

B B1 H H1 T Product
number
71 51 169 156 45 1010E
111 91 169 156 50 1020E
144 120 174 161 50 1030E
174 150 174 161 50 1040E H1 H

82 62 194 181 50 2010E


111 91 169 156 50 2020E
144 120 174 161 50 2030E
184 150 304 288 56 2050E B1
111 91 169 156 45 3005E B T
111 91 169 156 45 3010E
144 120 174 161 50 3020E
184 150 304 288 56 3030E

30
3G3MV inverter
Set of Parameters

Parameter Default MODBUS Name Adjustment range


number setting address

n001 1 101H Parameter record protection 0: Only n01 can be adjusted


Parameter initialising 1: n01--049 can be altered
2: n01--079 can be altered
3: n01--119 can be altered
5: not used
6: reset error memory
7: not used
8: initialising works adjustment (2--wire)
9: initialising works adjustment (3--wire)
n002 0 102H Choice of control mode 0: Terminal Volts/Hertz mode
1: Voltage vector control
n003 0 103H Start/Stop source 0: Operator console
1: via terminal strip
2: via modbus
n004 0 104H Reference value source 0: integrated potentiometer
1: parameter n024
2: 0..10 V
3: 4..20 mA
4: 0..20 mA
5: Pulse sequence
6: modbus
n005 0 105H Stop method 0: Stop at ramp (n020)
1: Spinning out the motor
n006 0 106H Backwards direction of rotation 0: Backwards released
1: Backwards blocked
n007 0 107H Operator stop button 0: Stop button at n03=1 button released
1: Stop button at n03= 1 blocked
n008 0 108H Reference value in local mode 0: integrated potentiometer
1: digital via operator (n024)
n009 0 109H Reference value input in local 0: complete input with ENTER
mode 1: no ENTER necessary
n010 0 10AH Action on lacking control element 0: no error
1: error signal
n011 60.0 Hz 10BH Maximum output frequency 50,0 Hz to 400 Hz

n012 200 V 10CH Max. output voltage 200V--class: 1 to 255 V


(400 V) 400V--class: 2 to 510 V
n013 60.0 Hz 10DH Corner frequency 0,2 Hz to 400 Hz
n014 1.5 Hz 10EH Middle output frequency 0,1 Hz to 399,9 Hz
n015 12 V 10FH Output voltage at middle output 200V--class: 0,1 V to 255 V
(24 V) frequency 400V--class: 0,2 V to 510 V
n016 1.5 Hz 110H Minimum output frequency 0,1 Hz to 10 Hz
n017 12 V 111H Output voltage at minimum output 200V--class: 0,1 V to 50 V
(24 V) frequency 400V--class: 0,2 V to 100 V
n018 0 112H Unit for braking/acceleration ramp 0: 0,0..999.9/1000..6000 s
1: 0,00..99.99/100.0..600,0 s
n019 10.0s 113H Acceleration time1 see n018
n020 10.0s 114H Braking time 1 see n018
n021 10.0s 115H Acceleration time 2 see n018
n022 10.0s 116H Braking time 2 see n018
n023 0 117H S curve slide on braking/ 0: no S--curve
accelerating 1: 0.2 s
2: 0.5 s
3: 1.0 s
n024 6.00 Hz 118H Frequency reference value 1 0,00 Hz to 400 Hz
n025 0.00 Hz 119H Frequency reference value 2 0,00 Hz to 400 Hz
n026 0.00 Hz 11AH Frequency reference value 3 0,00 Hz to 400 Hz
n027 0.00 Hz 11BH Frequency reference value 4 0,00 Hz to 400 Hz

31
3G3MV inverter
Set of Parameters (continued)

Parameter Default MODBUS Name Adjustment range


number setting address

n028 0.00 Hz 11CH Frequency reference value 5 0,00 Hz to 400 Hz


n029 0.00 Hz 11DH Frequency reference value 6 0,00 Hz to 400 Hz
n030 0.00 Hz 11EH Frequency reference value 7 0,00 Hz to 400 Hz
n031 0.00 Hz 11FH Frequency reference value 8 0,00 Hz to 400 Hz
n032 6.00 Hz 120H Jog frequency 0,00 Hz to 400 Hz
n033 100% 121H Max. reference value limit 0 % to 110 % of n011
n034 0 122H Min. reference value limit 0 % to 110 % of n011
n035 0 123H Frequency reference 0: 0.01 Hz
setting/display unit 1: 0.1%
2 to 39: rpm (number of motor poles)
40 to 3999: value can be set or monitored
at max. frequency
n036 depending on 124H Motor rated current for simulation 0..150% in relation to inverter rated current
model of motor protection switch
n037 0 125H Simulation of motor protection 0: Standard motor with standard rated data
switch 1: Standard motor for short--time operation
2: No thermal protection
n038 8 min 126H Thermal motor time constant 1 -- 60 min
n039 0 127H Function of ventilator (in the 0: only runs during RUN (1 min after STOP)
inverter) 1: always runs
n050 1 132H Multifunction input S1 1: forwards start (2--wire)
2: backwards start (2--wire)
3: external error (NO)
4: external error (NC)
5: Error reset
6: Fixed frequency 1
7: Fixed frequency 2
8: Fixed frequency 3
9: Fixed frequency 4
10: Jogging
11: Ramp change--over
12: external regulator block (NO)
13: external regulator block (NC)
14: Speed search of max. frequency
15: Speed search of assigned. frequency
16: Stopping during the ramp
17: Local/Remote change--over
18: Serial/operator change--over
19: Fast stop n022 (NO)
20: Fast stop n022 (NC)
21: Fast stop error (NO)
22: Fast stop error (NC)
n051 2 133H Multifunction input S2 see n050
n052 3 134H Multifunction input S3 0: Change in rotation direction (3--wire)
otherwise see n050
n053 5 135H Multifunction input S4 see n050
n054 6 136H Multifunction input S5 see n050
n055 7 137H Multifunction input S6 see n050
n056 10 138H Multifunction input S7 34: DOWN for motor poti (S6 automatic UP)
35: Self--test
otherwise see

32
3G3MV inverter
Set of Parameters (continued)

Parameter Default MODBUS Name Adjustment range


number setting address

n057 0 139H Multifunction output 0: Fault


MA, MB (relay) 1: Inverter in operation
2: Reference value reached
3: Zero frequency reached
4: Output frequency n095)
5: Output frequency n095
6: Over--torque (closer)
7: Over--torque (opener)
10: Alarm
11: Base block
12: active during local operation
13: Ready for operation
14: active during error reset
15: undervoltage detection
16: Backwards rotational direction
17: Trapping active
18: Data transfer via ModBus
19: PID Feedback loss
n058 1 13AH Multifunction output P1 like n057
n059 2 13BH Multifunction output P2 like n057
n060 100% 13CH Reinforcement of analog input 0..255%
n061 0% 13DH Offset of analog input --100..+100%
n062 0.1s 13EH Filter time for analog input 0,00..2.00 s
n064 0 140H Operation method for frequency ref- 0.1
erence loss detection Note: only for 5,5/7,5kW models
n065 0 141H Multi function analog output type 0.1
n066 0 142H Analog output holding 0: Output frequency
1: Motor current
n067 1 143H Analog output reinforcement 0,00..2,00
n068 100 0144 Multifunction analog voltage input --255..255%
gain
n069 0 0145 Multifunction analog voltage input --100..100%
bias
n070 0.10 0146 Multifunction analog voltage input 0.00..2.00 s
filter time constant
n071 100 0147 Multifuntion analog current input --255..255
gain
n072 0 0148 Multifunction analog current input --100..100%
bias
n073 0.10 0149 Multifunction analog current input 0.00..2.00 s
filter time constant
n074 100 014A Pulse train frequency reference 0..255%
gain
n075 0 014B Pulse train frequency reference --100..100%
bias
n076 0.10 014C Pulse train frequency reference 0.00..2.00 s
input filter time constant
n077 0 014D Multifunction analog input function 0..4
n078 0 014E Multifunction analog input signal 0.1
selection
n079 10 014F Frequency reference bias (FBIAS) 0..50%
value
n080 4 150H Clock frequency 1: 2,5 kHz
2: 5,0 kHz
3: 7,5 kHz
4: 10 kHz
7: 12 x motor frequency
8: 24 x motor frequency
9: 36 x motor frequency

33
3G3MV inverter
n081 0 151H Operation after short voltage 0: Error signal
breakdown 1: Error signal after >0,5 s
2: Operation is continued
n082 0 152H New start attempts after error 0..10
n083 0.00 Hz 153H Gating frequency 1 0,00..400 Hz
n084 0.00 Hz 154H Gating frequency 2 0,00..400 Hz
n085 0.00 Hz 155H Gating frequency 3 0,00..400 Hz
n086 0.00 Hz 156H Bandwidth of gating frequencies 0,00..25,50 Hz
n087 0.00 Hz 157H Cumulative operation time 0.1
selection Note: only for 5,5/7,5kW models
n088 0 158H Cumulative operation time 0 to 6550, 1=10H
Note: only for 5,5/7,5kW models
n089 0 159H SCurrent for d.c. braking 0..100% of the inverters rated current

n090 0.5s 15AH d.c. braking time at Stop 0,0..25,50 s


n091 0.5s 15BH d.c. braking time at Start 0,0..25,50 s
n092 0 15CH Protection against sweep on 0: switched on
braking 1: switched off (braking resistor!!)
n093 170% 15DH Level of protection against sweep 30..200% of the rated current
on accelerating
n094 160% 15EH Level of protection against sweep 30..200% of the rated current
during operation
n095 0.00 Hz 15FH Frequency recognition level 0,00..400 Hz
n096 0 160H Over--torque detection 1 0: no detection
1: Detection at constant speed, no error signal
2: Detection at constant speed, with error signal and stop
3: Always detection, no error signal
4: Always detection with error signal and stop
n097 0 161H Over--torque detection 2 0: Detection via current
1: Detection via torque
n098 160% 162H Level of torque detection 30..200%
n099 0.1s 163H Time of torque detection 0,1.10 s
n100 0 164H Storing of reference value during 0: No storing after STOP
motor poti operation 1: Storing after STOP
n101 2.0 165H Speed search deceleration time 0,0..10,0s
Note: only for 5,5/7,5kW models
n102 150 166H Speed search operation level 0..200%
Note: only for 5,5/7,5kW models
n103 1.0 167H Torque boost 0,0..2.5
n104 0.3s 168H Delay time for boost 0,0..25.5 s
n105 depending on 169H Iron losses in motor 0,0..6550 W
model
n106 depending on 16AH Rated slip 0,0..20.0 Hz
model
n107 depending on 16BH Motor coil resistance 0,000..65,50 W
model
n108 depending on 16CH Motor inductance 0,00..655,0 mH
model
n109 150% 16DH Torque limit 0..250%
n110 depending on 16EH no--load current 0..99%
model
n111 0.0 16FH Slip compensation reinforcement 0,0..2,5
n112 2.0s 170H Delay time for slip compensation 0,0..25,5 s
n113 0 171H Slip compensation on braking 0: not active
1: active
n115 0 173H Stall prevention level automatic 0.1
suppression selection
n116 0 174H Stall prevention acc/dec time set- 0.1
ting

34
3G3MV inverter
Set of Parameters (continued)

Parameter Default MODBUS Name Adjustment range


number setting address

n120 0.00 Hz 178H Frequency reference value 9 0,00..400 Hz


n121 0.00 Hz 179H Frequency reference value 10 0,00..400 Hz
n122 0.00 Hz 17AH Frequency reference value 11 0,00..400 Hz
n123 0.00 Hz 17BH Frequency reference value 12 0,00..400 Hz
n124 0.00 Hz 17CH Frequency reference value 13 0,00..400 Hz
n125 0.00 Hz 17DH Frequency reference value 14 0,00..400 Hz
n126 0.00 Hz 17EH Frequency reference value 15 0,00..400 Hz
n127 0.00 Hz 17FH Frequency reference value 16 0,00..400 Hz
n128 0 180H PID control selection 0: PID control disabled
1 to 8: PID control enabled
n129 1.00 181H Feedback value adjustment gain 0,00 to 10,00
n130 1.0 182H Proportional (P) gain 0,0 to 25,0
n131 1.0 183H Integral (I) time 0,0 to 360,0 s
n132 0.00 184H Derivative (D) time 0,00 to 2,50 s
n133 0 185H PID offset adjustment --100 to 100 %
n134 100 186H Integral (I) upper limit 0 to 100 %
n135 0.0 187H PID primary delay time 0,0 to 10,0 s
n136 0 188H Feedback loss detection level 0: Feedback loss detection disabled
1: Feedback loss detection enabled
(Nonfatal error: FbL warning)
2: Feedback loss detection enabled
(Fatal error: FbL fault)
n137 0 189H Feedback loss detection level 0 to 100 %
n138 1.0 18AH Feedback loss detection time 0,0 to 25,5
n139 0 18BH Energy saving control selection 0: disabled
1: enabled
n140 Varies with 18CH Energy saving control coefficient 0,0 to 6550
capacity K2
n141 50 18DH Energy saving voltage lower limit at 0 to 120 %
60Hz output
n142 12 18EH Energy saving voltage lower limit at 0 to 25 %
6Hz output
n143 1 18FH Power averaging time 1 to 200 ms
n144 0 190H Probe operation voltage limit 0 to 100 %
n145 0.5 191H Probe operation control voltage 0,1 to 10,0 %
step at 100%
n146 0.2 192H Probe operation control voltage 0,1 to 10,0 %
step at 5%
n149 2500 195H Scaling pulse input 100..3000 (x10Hz)
n150 0 195H Multi--function analog output, pulse 0: 1440Hz at max. frequency
train frequency selection 1: 1x output frequency
6: 6x output frequency
12: 12x output frequency
24: 24x output frequency
36: 36x output frequency
n151 0 197H RS422/485 communications time-- 0: Spinning out
over detection selection 1: STOP with ramp 1 (n020)
2: STOP with ramp 2 (n022)
3: no STOP, alarm signal
4: no STOP
n152 0 198H RS422/485 communications fre- 0: 0,1 Hz
quency reference/display unit 1: 0,01 Hz
selection 2: 30000 = max. frequency
3: 0,1 %
n153 0 199H RS422/485 slave address 0..31

35
3G3MV inverter
n154 0 19AH RS422/485 baud rate 0: 2400 Kbaud
1: 4800 Kbaud
2: 9600 Kbaud
3: 19200 Kbaud
n155 0 19BH RS422/485 parity 0: straight
1: not straight
2: no parity
n156 10ms 19CH RS422/485 waiting time when 10..65 ms
sending
n157 0 19DH RS422/485 RTS control 0: RTS control
1: RS422A, 1:1 link
n158 Varies with 19EH Motor code 0 to 70
capacity
n159 120 19FH Energy saving voltage upper limit 0 to 120 %
at 60Hz output
n160 16 1A0H Energy saving voltage upper limit 0 to 25 %
at 6Hz output
n161 10 1A1H Power detection width for probe 0 to 100 %
operation switching
n162 5 1A2H Power detection filter constant 0 to 255 ms
n163 1,0 1A3H PID output gain 0,0 to 25,0
n164 0 1A4H PID feedback input block selection 0: frequency reference control terminal for voltage
input (0 to 10V) is enabled
1: frequency reference control terminal for current
input (4 to 20mA) is enabled
2: frequency reference control terminal for current
input (0 to 2--mA) is enabled
3: multi--function analog voltage input (0 to 10V) is
enabled
4: multi--function analog current input (4 to 20mA)
is enabled
5: pulse train reference control terminal is enabled
n165 0 1A5H Installed braking resistor 0: disabled
overheating protection 1: enabled
Note: only for 5,5/7,5kW models
n166 0 1A6H Input open phase detection level 0 to 100%
Note: only for 5,5/7,5kW models
n167 0 1A7H Input open phase detection time 0 to 255s
Note: only for 5,5/7,5kW models
n168 0 1A8H Output open phase detection level 0 to 100%
Note: only for 5,5/7,5kW models
n169 0,0 1A9H Output open phase detection tiime 0..2.0s
Note: only for 5,5/7,5kW models
n175 0 1AFH Low speed carrier frequency 0: disabled
reduction selection 1: enabled
n176 rdy 1B0H Parameter copy and verify function rdy: ready to accept the nect command
selection rEd: reads the inverter parameter
Cpy: copies the parameter to the inverter
vFy: verifies the inverter parameter
vA: checks the inverter capacity display
Sno: checks the software number
n177 0 1B1H Copy--prohibit function 0: read prohibited for inverter parameters
(data cannot be stored in EEPROM)
1: read possible for invertr parameters
(data can be stored in EEPROM)
n178 ---- 1B2H Fault log
n179 1B3H Software number

36
3G3MV inverter
Set of Parameters (continued)

Apart from the parameters which are accessible through the


programming unit and MODBUS communication, there are other
parameters which can only be operated and read through
MODBUS communication.

MODBUS address Name Function Access*


0001h Control word Bit R, W

Start / Stop 0 1 Run; 0 Stop


Selection of rotational direction 1 1 Reverse; 0 Forward
External error 1 1 Error (EF0)
Reset after error 3 1 Error reset
Multifunction input S1 4 1 Input S1 selected
Multifunction input S2 5 1 Input S2 selected
Multifunction input S3 6 1 Input S3 selected
Multifunction input S4 7 1 Input S4 selected
Multifunction input S5 8 1 Input S5 selected
Multifunction input S6 9 1 Input S6 selected
Multifunction input S7 A 1 Input S7 selected
9
10
11
12
13
14
15
0002H Frequency reference value in units as given in R, W
n152
0003H V/f gain R, W
0009H Multifunction outputs MA, P1, P2 Bit R, W
(n057--n059=18)
0 Multifunction output MA
1 Multifunction output P1
2 Multifunction output P2
0020H R
Bit

Start / Stop 0 1 Start; 0 Stop


Selection of rotational direction 1 1 Reverse; 0 Forward
Inverter readiness for operation 2 1 Ready for operation 0 Not ready for oper.
3 1 Fault; 0 No fault
Inverter error 4 1 Parameter error;
Invalid parameter entry 0: No parameter error
5 1 active
Multifunction output MA 0 not active
6 1 active
Multifunction output P1 0 not active
7 1 active
Multifunction output P2 0 not active
8
9
10
11
12
13
14
15

37
3G3MV inverter
Set of Parameters (continued)

MODBUS address Name Function Access*


0021H Inverter error Bit R

1 Overcurrent (OC)
2 Overvoltage (OV)
3 Inverter overload (OL2)
3 Inverter overheat (OH)
4
5
6
7 External error (EF0, EF)
8 Hardware error(CPFxx)
9 Motor overload (OL1)
10 Over--torque (OL3)
11
12 Line cut--off (UV1)
13 Control voltage error (UV2)
14 Bus error (BUS)
15 Control element error (OPR)
0022H Status inverter communication Bit R

Data transfer 0 1 during data recording


1
2
Range error parameter 3 Range error
4 Data inconsistency
5
6
7
8
9
10
11
12
13
14
15
0023H Frequency reference value in units of n152 R
0024H Frequency actual value in units of n152 R
0027H Output current(10 / A)
0028H Output voltage(1 / V)
002BH Binary inputs Bit R
Multifunction input S1 0 1 input active
Multifunction input S2 1 1 input active
Multifunction input S3 2 1 input active
Multifunction input S4 3 1 input active
Multifunction input S5 4 1 input active
Multifunction input S6 5 1 input active
Multifunction input S7 6 1 input active
002CH R
Bit

Operating condition 0 1 Operation; 0: no operation


Standstill signal 1 1 Standstill; 0: Motor turning
Frequency reference value reached 2 1 reached; 0: not reached
Alarm 3 1 Alarm; 0: no alarm
Rotating field frequency n095 4 1 yes; 0: no
Rotating field frequency n095 5 1 yes; 0: no
Inverter is ready for operation 6 1 yes; 0: no
Undervoltage detection 7 1 undervoltage 0 no undervoltage
8 1 yes; 0: no
Base block 9 1 not serial; 0: serial
Reference value source 10 1 not serial; 0: serial
Inverter control
11 1 registered; 0: not registered
Over--torque detection 12
13
14 1 yes; 0: no
Bad error (including transfer) 15 1 yes; 0: no
Transfer error

38
3G3MV inverter
Set of Parameters (continued)

MODBUS address Name Function Access*


002DH Bit R
Multifunction output MA 0 1 active
Multifunction output P1 1 1 active
Multifunction output P2 2 1 active
0031H Intermediate circuit voltage(1 / V)
0032H Torque
003DH Communication error Bit R

0 CRC error
1 Data length wrong
2
3 Parity error
4 Overrun error
5 Frame error
6 Time over
7
8
9
10
11
12
13
14
15

The following MODBUS functions can be carried out using a


Broadcast order (all connected inverters are described at the same
time, slave address = 0).

MODBUS address Name Function Access*


0001h Control word Bit BC

Start/Stop 0 1 Run; 0 Stop


Direction of rotation selection 1 1 Reverse; 0 Forward
2
3
External error 4 1 Input selected
Error reset 5 1 active
6
7
8
9
10
11
12
13
14
15
0002H Frequency reference value 30000 = 100% BC

* R = Read only
W = Write only
BC = Broadcast

39
3G3MV inverter

40
3G3HV inverter
General

The 3G3HV is designed in particular for applications with quadratic


power requirement. Pumps and ventilators are always operated with
the highest efficiency by means of a self-adapting energy saving
function.

Features:
-- power range: 0,4...300 kW
-- PID controller
-- self-adapting energy saving function
-- NPN or PNP digital inputs
-- analog frequency default: 0...10 VDC or 4...20 mA
-- high continuous output current
-- low noise thanks to high carrier frequency (adjustable to 15 kHz)
-- built-in programming unit
-- MODBUS interface RS-422/-485
-- built-in DC reactor above 15 kW
-- 12 pulse rectifier above 15 kW

System architecture

To comply with relevant EMC guidelines it is imperative for


Variable-frequency inverters always to be operated with
appropriate line filters and according to the relevant installation
instructions.

Switch cabinet assembly


on metal plate
Voltage Contact surfaces to the
supply Shielding metal plate
L1
L2
L3
PE

Line filter,
footprint type

Shielding
U
V M
W
PE

41
3G3HV inverter
Product overview

Inverter: 200 V Class: Model 3G3HV--AB_--CE

3G3HV--A B004 B007 B015 B022 B037


Maximum allowed motor output kW 0,55 1,1 1,5 2,2 3,7
Output data Inverter performance kVA 1,2 2,3 3,0 4,2 6,7
Output rated current A 3,2 6 8 11 17,5

Inverter: 400 V Class: Model 3G3HV--A4_--CE

3G3HV--A 4004 4007 4015 4022 4037 4040 4055 4075 4110 4150
Maximum allowed motor output kW 0,55 1,1 1,5 2,2 3,7 4,0 5,5 7,5 11 15
Output data Inverter performance kVA 1,4 2,6 3,7 4,7 6,1 8,4 11 14 21 26
Output rated current A 1,8 3,4 4,8 6,2 8 11 14 18 27 34

3G3HV--B 4185 4220 4300 4370 4450 4550 4750 411K 416K
Maximum allowed motor output kW 18,5 22 30 37 45 55 75 110 160
Output data Inverter performance kVA 31 40 50 61 73 98 130 170 230
Output rated current A 41 52 65 80 96 128 165 224 302

3G3HV--B 418K 422K 430K


Maximum allowed motor output kW 185 220 300
Output data Inverter performance kVA 260 340 460
Output rated current A 380 506 675

Accessories
Line filter

Line filter Rated voltage Line filter Current*


3G3HV--AB004--CE 1 x 230 VAC 3G3HV--PFI1010--E 10 A
3G3HV--AB007--CE and 3G3HV--AB015--CE 1 x 230 VAC 3G3HV--PFI1020--E 20 A
3G3HV--AB022--CE and 3G3HV--AB037--CE 1 x 230 VAC 3G3HV--PFI1040--E 40 A
3G3HV--A4004--CE and 3G3HV--A4007--CE 3 x 400 VAC 3G3FV--PFI4012--E* 12 A
3G3HV--A4015--CE 3 x 400 VAC 3G3FV--PFI4012--E* 12 A
3G3HV--A4022--CE 3 x 400 VAC 3G3FV--PFI4012--E* 12 A
3G3HV--A4037--CE and 3G3HV--A4040--CE 3 x 400 VAC 3G3FV--PFI4012--E* 12 A
3G3HV--A4055--CE 3 x 400 VAC 3G3FV--PFI4025--E* 25 A
3G3HV--A4075--CE 3 x 400 VAC 3G3FV--PFI4025--E* 25 A
3G3HV--A4110--CE 3 x 400 VAC 3G3FV--PFI4040--E* 40 A
3G3HV--A4150--CE 3 x 400 VAC 3G3FV--PFI4040--E* 40 A
3G3HV--B4185--CE and 3G3HV--B4220--CE 3 x 400 VAC 3G3FV--PFI4060--E 60 A
3G3HV--B4300--CE and 3G3HV--B4370--CE 3 x 400 VAC 3G3FV--PFI4100--E 100 A
3G3HV--B4450--CE 3 x 400 VAC 3G3FV--PFI4120--E 120 A
3G3HV--B4550--CE 3 x 400 VAC 3G3FV--PFI4150--E 150 A
3G3HV--B4750--CE 3 x 400 VAC 3G3FV--PFI4180--E 180 A
3G3HV--B411K--CE 3 x 400 VAC 3G3FV--PFI4280--E 280 A
3G3HV--B418K--CUE 3 x 400 VAC 3G3FV--PFI4450--E 450 A
3G3HV--B418K--CUE 3 x 400 VAC 3G3FV--PFI4450--E 450 A
3G3HV--B422K--CUE 3 x 400 VAC 3G3FV--PFI4600--E 600 A
3G3HV--B430K--CUE 3 x 400 VAC 3G3FV--PFI4900--E 900 A

* footprint type

42
3G3HV inverter
Accessories (continued)

Brake choppers, braking resistors

Inverter Rated voltage Brake chopper Number Braking resistors Number Specification
for each unit

for inverter, single-phase 230 V


3G3HV--AB004--CE 1 x 230 VAC built-in -- 3G3IV--PERF150W--J620 1 62 W , 150 W
3G3HV--AB007--CE 1 x 230 VAC built-in -- 3G3IV--PERF150W--J620 1 62 W , 150 W
3G3HV--AB015--CE 1 x 230 VAC built-in -- 3G3IV--PERF150W--J620 1 62 W , 150 W
3G3HV--AB022--CE 1 x 230 VAC built-in -- 3G3IV--PERF150W--J620 1 62 W , 150 W
3G3HV--AB037--CE 1 x 230 VAC built-in 3G3IV--PERF150W--J620 1 62 W , 150 W

for inverter, three-phase 400 V


3G3HV--A4004--CE 3 x 400 VAC built-in -- 3G3IV--PERF150W--J101 1 100 W , 150 W
3G3HV--A4007--CE 3 x 400 VAC built-in -- 3G3IV--PERF150W--J101 1 100 W , 150 W
3G3HV--A4015--CE 3 x 400 VAC built-in -- 3G3IV--PERF150W--J101 1 100 W , 150 W
3G3HV--A4022--CE 3 x 400 VAC built-in -- 3G3IV--PERF250W--J680T 1 68 W , 250 W
3G3HV--A4037--CE 3 x 400 VAC built-in -- 3G3IV--PERF500W--J360T 1 36 W , 500 W
3G3HV--A4040--CE 3 x 400 VAC built-in -- 3G3IV--PERF500W--J360T 1 36 W , 500 W
3G3HV--A4055--CE 3 x 400 VAC built-in -- 3G3IV--PERF500W--J360T 1 36 W , 500 W
3G3HV--A4075--CE 3 x 400 VAC built-in -- 3G3IV--PERF101W--J360T 1 36 W , 1000 W
3G3HV--A4110--CE 3 x 400 VAC built-in -- 3G3IV--PERF151W--J200T 1 20 W , 1500 W
3G3HV--A4150--CE 3 x 400 VAC built-in -- 3G3IV--PERF151W--J200T 1 20 W , 1500 W

Other

Description Cable length Product number


Adapter for front panel installation, fixed mounting of console -- 3G3FV--PDACT--AD
Adapter for front panel installation, removable console -- 3G3FV--PDACT--BD
Extension cable to programming console 1m 3G3FV--PCN125
Extension cable to programming console 3m 3G3FV--PCN325
Ferrite rings for output, D = 21 to 58 mm -- 3G3IV--PFO--OC1--OC4

43
3G3HV inverter
Programming accessories

PC programming Description Cable length Product number


Programming software under WINDOWS -- SYSDRIVE Configurator

Connecting cable 2m 3G3FV--PCNDW225N

Technical data

Type 3G3HV--A4_--CE 3G3HV--B4_--(--CE) 3G3HV--AB_--CE


Output data Max. output voltage three-phase: 380/400/415/440/460 V (prop. to input volt.) three-phase: 200-240 V
(prop. to input volt.)
Output frequency 0,1 Hz to 400 Hz
Supply Rated input voltage and three-phase: 380/400/415/440/460 V, 50/60 Hz three-phase: 200-240 V,
frequency 50/60 Hz
Allowed voltage variation +10%, --15%
Allowed frequency variation 5%
Control functions Type of control sinusoidal pulse width modulation (PWM)
Output frequency range 0,1-400 Hz
Frequency precision digital default: 0,01% (--10C to +40C)
analog default: 0,1% (25C 10C)
Frequency resolution digital default: 0,1 Hz
analog default: 0,05 Hz, 50 Hz (10 Bits)
Output frequency resolution 0.01 Hz
Overload capacity 150% of the output rated 120% of the output rated current for 1 minute
current for 1 minute 150% for 12 s
Frequency reference value signal 0-10 VDC (20 kW ), 4-20 mA (250 W )
Acceleration/deceleration 0,0 bis 3600 s (can be programmed independently)
Braking torque about 20% (with braking about 20%
resistor up to 125%)
U/f characteristics 15 already programmed and one freely programmable characteristic
Protective Protection against motor thermo-electronic protection against overload
functions overload
Instantaneous overcurrent stops at approx. 200% of stops at approx. 180% of rated output current
rated output current
Overload at 150% of the output rated at 120% of the output rated current the motor coasts to
current the motor coasts to stop after 1 minute
stop after 1 minute
Overvoltage stops when main circuit DC voltage is approx. 820 V
Undervoltage stops when main circuit DC voltage is approx. 380 V (400 V model)
Supply voltage failure after failure of longer than 15 ms the output switches off. After the return of voltage
operation can be automatically continued.
Cooling fin overheating protection by thermistor
Stall prevention stall prevention during the acceleration and braking phase, and also during constant fre-
quency operation
Earth fault via electronic circuit
Charge indicator the charge indicator lights up until the intermediate circuit voltage falls under 50 V

44
3G3HV inverter
Technical data (continued)

Type 3G3HV--A4_--CE 3G3HV--B4_--(--CE) 3G3HV--AB_--CE


Ambient conditions Ambient temperature during --10C to +45C --10C to +45C --10C to +45C
operation
Air humidity 90% RH (without condensation)
Storage temperature --20C to +60C
Place of assembly inside ( protected against corrosive gases and dust)
Vibrations 1 G at 0...20 Hz
0,2 G at 20...50 Hz

Connections diagram

200 V Class, 0,4...3,7 kW, single-phase

DC reactor
(optional)
Voltage supply Braking resistor
200...240 VAC, 50/60 Hz (optional)

Line Line
fuse contactor Line filter +1 +2 -- B1 B2

L1 U
N V M
W
3--phase

PNP connection NPN connection AM

Forwards-Start/-Stop Forwards-Start/-Stop Multifunction


S1 S1 analog output
Multifunction input 1 Multifunction input 1 AC
S2 S2 Analog output, mass
Multifunction input 2 Multifunction input 2
S3 S3
Multifunction input 3 Multifunction input 3
S4 S4
Multifunction input 4 Multifunction input 4
S5 S5
Multifunction input 5 Multifunction input 5
S6 S6
SP
24 V SC

SS SS
SC SP
0V 24 V

Multifunction
output 1
MA
Auxiliary voltage 15 V, 20 mA FS Multifunction contact output
(contact a)
MB
Ref. value input 1, 0...10 V FV contact b
(main frequency ref. value)
MC
Ref. value input 2, 4...20 mA FI Common

Ref. common FC M1
Multifunction
M2 output 2
(R+)
Serial interface (R--)
RS--485/--422
(shielded in pairs) (S+)
(S--) E

45
3G3HV inverter
Connections diagram (continued)

400 V Class, 0,4...15 kW, three-phase


DC reactor
(optional)
380...460 VAC, 50/60 Hz Braking resistor
three-phase (optional)

Line Line
fuse contactor Line filter +1 +2 -- B1 B2

R U
S V M
T W
3--phase

PNP connection NPN connection AM

Forwards-Start/-Stop Forwards-Start/-Stop Multifunction


S1 S1 analog output
Multifunction input 1 Multifunction input 1 AC
S2 S2 Analog output, mass
Multifunction input 2 Multifunction input 2
S3 S3
Multifunction input 3 Multifunction input 3
S4 S4
Multifunction input 4 Multifunction input 4
S5 S5
Multifunction input 5 Multifunction input 5
S6 S6
SP
24 V SC

SS SS
SC SP
0V 24 V
E
Multifunction
output 1
MA
Auxiliary voltage 15 V, 20 mA FS Multifunction contact output
(contact a)
MB
Ref. value input 1, 0...10 V FV contact b
(main frequency ref. value)
MC
Ref. value input 2, 4...20 mA FI Common

Ref. common FC M1
Multifunction
M2 output 2
(R+)
Serial interface (R--)
RS--485/--422
(shielded in pairs) (S+)
(S--) E

46
3G3HV inverter
Connections diagram (continued)

400 V Class, 18,5...300 kW, three-phase


-- Brake chopper on demand. 380...460 VAC, 50/60 Hz
three-phase

Line Line
fuse contactor Line filter
R U
S V M
T W
3--phase

AM
R1
S1
Multifunction
PNP connection NPN connection T1 analog output
AC
Forwards-Start/-Stop Forwards-Start/-Stop Analog output, mass
S1 S1
Multifunction input 1 Multifunction input 1
S2 S2
Multifunction input 2 Multifunction input 2
S3 S3
Multifunction input 3 Multifunction input 3
S4 S4
Multifunction input 4 Multifunction input 4
S5 S5
Multifunction input 5 Multifunction input 5
S6 S6
SP
24 V SC

SS
SS
SC
0V SP
24 V
E

Auxiliary voltage 15 V, 20 mA FS Multifunction


output 1
MA
Ref. value input 1, 0...10 V FV Multifunction contact output
(main frequency ref. value) (contact a)
MB
Ref. value input 2, 4...20 mA FI contact b
MC
Ref. common FC Common

M1
(R+) Multifunction
Serial interface (R--) M2 output 2
RS--485/--422
(shielded in pairs) (S+)
(S--) E

47
3G3HV inverter
Technical documentation

English Product Title Product number


documentation
3G3HV User Manual I515--E1--2

SYSDRIVE INVERTER
Installation Manual I520--E1--1

OPERATION MANUAL

Dimensions (mm)

Inverter
3G3HV--AB_, 200 V single-phase

B B1 H H1 T Weight Product
kg number
140 126 280 266 160 3 004--CE
140 126 280 266 180 4,5 007--CE
140 126 280 266 180 4,5 015--CE
200 186 300 285 205 6 022--CE
200 186 300 285 205 6 037--CE

H1 H
3G3HV--A4_, 400 V three-phase, up to 15 kW

B B1 H H1 T Weight Product
kg number
140 126 280 266 160 3 004--CE
140 126 280 266 160 3 007--CE
140 126 280 266 180 4 015--CE
140 126 280 266 180 4,5 022--CE B1 T
140 126 280 266 180 4,5 037--CE B
140 126 280 266 180 4,5 040--CE
200 186 300 285 205 6 055--CE
200 186 300 285 205 6 075--CE
250 236 380 365 225 11 110--CE
250 236 380 365 225 11 150--CE

48
3G3HV inverter
Dimensions (mm) (continued)

Inverter
3G3HV--B_, 400 V three-phase, >15 kW

B B1 H H1 T Product
number
325 275 450 435 285 4185--CE
325 275 450 435 285 4220--CE
325 275 625 610 285 4300--CE
325 275 625 610 285 4370--CE
625 610 285 H1 H
325 275 4450--CE
455 350 820 795 350 4550--CE
455 350 820 795 350 4750--CE
575 445 925 895 375 411K--CE
575 445 925 895 400 416K--CE
950 * 1450 1400 435 418K--CUE
B1 T
950 * 1450 1400 435 422K--CUE
B
960 * 1600 1550 455 430K--CUE
* on demand

Line filter
3G3HV--PFI_, 200 V single-phase, mountable underneath up to 15 kW

B B1 H H1 T Product
number
143 90 320 310 46 1010--E
143 90 320 310 46 1020--E
213 150 320 310 51 1040--E
H1 H

3G3FV--PFI_, 400 V three-phase, mountable underneath

B B1 H H1 T Product
number
143 90 320 310 40 4012--E B1
213 150 350 330 40 4025--E B T
266 200 435 415 55 4040--E

3G3FV--PFI_, 400 V three-phase from 18,5 kW

B B1 H H1 T Product
number
140 106 270 258 90 4060--E
180 146 350 338 90 4100--E
200 166 420 408 130 4120--E
200 166 420 408 130 4150--E H1 H

200 166 480 468 160 4180--E


200 166 480 468 160 4280--E
250 170 587 560 205 4450--E

B1

B T

49
3G3HV inverter

50
3G3FV inverter
General

The 3G3FV is a frequency inverter of the top class. It is equipped with


real flux vector control of the latest generation. This allows a holding
torque (standstill) of 100% long-term and up to 150% short-term. This
is an important point in particular for elevators and lifts.
In addition flux vector control permits precise torque control. This is of
great advantage for coil winders or axis driven at both ends.
Starting-up is facilitated by an LCD display with indications in
7 languages. If the inverter should ever fail, it shows all the data at the
moment of failure (current, voltage etc.). In this way trouble location is
made much easier and the standstill time is minimised. Many pro-
tective functions (protection against short-circuit, excess voltage and
overload) ensure that the inverter and your plant are not damaged in
the event of a failure.

Features:
-- high torque -- position lock at 0speed
-- high speed stability during load variations -- protection against short-circuit, excess / insufficient voltage and
-- torque control (winder, load sharing) overload
-- built-in PID controller -- saving of electrical operating circumstances at moment of failure
-- fast analog input (< 2 ms) -- 8 switchable digital NPN or PNP inputs
-- high dynamics thanks to 32 bit DSP -- analog frequency default: 0-10 VDC or 4-20 mA
-- neuro-fuzzy allows short start and stop times -- high continuous output current
-- self-adjustment to the motor (auto-tuning) -- low noise thanks to 15 kHz carrier frequency
-- slip compensation for motor and generator operation -- built-in programming unit, also may be mounted on front panel
-- built-in timing element (e.g. for delayed response of mechanical -- built-in RS-232C/-422/-485
brakes) -- Windows software for programming

System architecture

To comply with relevant EMC guidelines it is imperative for


frequency inverters always to operate with
appropriate line filters and according to the relevant installation
instructions.

Switch cabinet assembly


on metal plate
Voltage Contact surfaces to
supply Shielding the metal plate
L1
L2
L3
PE

Line filter,
footprint type

Shielding
U
V M
W
PE

51
3G3FV inverter
Product overview

Inverter: 3G3FV--A4_--CUE

3G3FV--A 4004--CUE 4007--CUE 4015--CUE 4022--CUE 4037--CUE


Maximum allowed motor output kW 0,55 1,1 1,5 2,2 3,7
Output data Inverter performance kVA 1,4 2,6 3,7 4,7 6,1
Output rated current A 1,8 A 3,4 4,.8 6,2 8

3G3FV--A 4040--CUE 4055--CUE 4075--CUE 4110--CUE 4150--CUE


Maximum allowed motor output kW 4,0 5,5 7,5 11 15
Output data Inverter performance kVA 8,6 11 14 21 26

Output rated current A 11 14 18 27 34

Inverter: 3G3FV--B4_--CUE

3G3FV--B 4185--CUE 4220--CUE 4300--CUE 4370--CUE 4450--CUE 4550--CUE


Maximum allowed motor output kW 18,5 22 30 37 45 55
Output data Inverter performance kVA 31 40 50 61 73 98
Output rated current A 41 52 65 80 96 128

3G3FV--B 4750--CUE 411K--CUE 416K--CUE 418K--CUE 422K--CUE 430K--CUE


Maximum allowed motor output kW 75 110 160 185 220 300
Output data Inverter performance kVA 130 170 230 260 340 460

Output rated current A 165 224 302 340 450 605

Accessories

Line filter

Inverter Rated voltage Line filter Current


3G3FV--A4004--CUE 3 x 400 VAC 3G3FV--PFI4012--E* 12 A
3G3FV--A4007--CUE
3G3FV--A4015--CUE 3 x 400 VAC 3G3FV--PFI4012--E* 12 A
3G3FV--A4022--CUE 3 x 400 VAC 3G3FV--PFI4012--E* 12 A
3G3FV--A4037--CUE 3 x 400 VAC 3G3FV--PFI4012--E* 12 A
3G3FV--A4040--CUE
3G3FV--A4055--CUE 3 x 400 VAC 3G3FV--PFI4025--E* 25 A
3G3FV--A4075--CUE 3 x 400 VAC 3G3FV--PFI4025--E* 25 A
3G3FV--A4110--CUE 3 x 400 VAC 3G3FV--PFI4040--E* 40 A
3G3FV--A4150--CUE 3 x 400 VAC 3G3FV--PFI4040--E* 40 A
3G3FV--B4185--CUE 3 x 400 VAC 3G3FV--PFI4060--E 60 A
3G3FV--B4220--CUE 3 x 400 VAC 3G3FV--PFI4060--E 60 A
3G3FV--B4300--CUE 3 x 400 VAC 3G3FV--PFI4100--E 100 A
3G3FV--B4370--CUE 3 x 400 VAC 3G3FV--PFI4100--E 100 A
3G3FV--B4450--CUE 3 x 400 VAC 3G3FV--PFI4120--E 120 A
3G3FV--B4550--CUE 3 x 400 VAC 3G3FV--PFI4150--E 150 A
3G3FV--B4750--CUE 3 x 400 VAC 3G3FV--PFI4180--E 180 A
3G3FV--B411K--CUE 3 x 400 VAC 3G3FV--PFI4280--E 280 A
3G3FV--B416K--CUE 3 x 400 VAC 3G3FV--PFI4450--E 450 A
3G3FV--B418K--CUE
3G3FV--B422K--CUE 3 x 400 VAC 3G3FV--PFI4600--E 600 A
3G3FV--B430K--CUE 3 x 400 VAC 3G3FV--PFI4900--E 900 A

* footprint design

52
3G3FV inverter
Accessories (continued)

Brake choppers, braking resistors for frequency inverters, 3-phase 400 V

Inverter Rated voltage Braking chopper Number Braking resistors Number Specification
for each unit
3G3FV--A4004--CUE 3 x 400 VAC built-in -- 3G3IV--PERF150W--J101 1 100 W , 150 W
3G3FV--A4007--CUE 3 x 400 VAC built-in -- 3G3IV--PERF150W--J101 1 100 W , 150 W
3G3FV--A4015--CUE 3 x 400 VAC built-in -- 3G3IV--PERF150W--J101 1 100 W , 150 W
3G3FV--A4022--CUE 3 x 400 VAC built-in -- 3G3IV--PERF250W--J680T 1 68 W , 250 W
3G3FV--A4037--CUE 3 x 400 VAC built-in -- 3G3IV--PERF500W--J360T 1 36 W , 500 W
3G3FV--A4040--CUE 3 x 400 VAC built-in -- 3G3IV--PERF500W--J360T 1 36 W , 500 W
3G3FV--A4055--CUE 3 x 400 VAC built-in -- 3G3IV--PERF500W--J360T 1 36 W , 1000 W
3G3FV--A4075--CUE 3 x 400 VAC built-in -- 3G3IV--PERF101W--J360T 1 36 W , 1000 W
3G3FV--A4110--CUE 3 x 400 VAC built-in -- 3G3IV--PERF151W--J200T 1 20 W , 1500 W
3G3FV--A4150--CUE 3 x 400 VAC built-in -- 3G3IV--PERF151W--J200T 1 20 W , 1500 W
3G3FV--B4185--CUE 3 x 400 VAC 3G3IV--PCDBR 4030B 1 3G3IV--PERF601W--J200T 1 20 W , 6000 W
3G3FV--B4220--CUE 3 x 400 VAC 3G3IV--PCDBR 4030B 1 3G3IV--PERF601W--J200T 1 20 W , 6000 W
3G3FV--B4300--CUE 3 x 400 VAC 3G3IV--PCDBR 4030B 1 3G3IV--PERF601W--J200T 1 20 W , 6000 W
3G3FV--B4370--CUE 3 x 400 VAC 3G3IV--PCDBR 4045B 1 3G3IV--PERF961W--J100T 1 10 W , 9600 W
3G3FV--B4450--CUE 3 x 400 VAC 3G3IV--PCDBR 4045B 1 3G3IV--PERF961W--J100T 1 10 W , 9600 W
3G3FV--B4550--CUE 3 x 400 VAC 3G3IV--PCDBR 4030B 2 3G3IV--PERF601W--J200T 2 20 W , 6000 W
3G3FV--B4750--CUE 3 x 400 VAC 3G3IV--PCDBR 4045B 2 3G3IV--PERF961W--J100T 2 10 W , 9600 W
3G3FV--B411K--CUE 3 x 400 VAC 3G3IV--PCDBR 4030B 3 3G3IV--PERF601W--J200T 3 20 W , 6000 W
3G3FV--B416K--CUE 3 x 400 VAC 3G3IV--PCDBR 4045B 4 3G3IV--PERF961W--J100T 4 10 W , 9600 W
3G3FV--B418K--CUE 3 x 400 VAC 3G3IV--PCDBR 4045B 4 3G3IV--PERF961W--J100T 4 10 W , 9600 W
3G3FV--B422K--CUE 3 x 400 VAC 3G3IV--PCDBR 4045B 5 3G3IV--PERF961W--J100T 5 10 W , 9600 W
3G3FV--B430K--CUE 3 x 400 VAC 3G3IV--PCDBR 4045B 6 3G3IV--PERF961W--J100T 6 10 W , 9600 W

Other accessories

Description Product number


Encoder cards for speed control in U/f operation, 30 kHz, 12 VDC 3G3FV--PPGA2
for vector control, 30 kHz, 12 VDC 3G3FV--PPGB2
for speed control in U/f operation, 300 kHz, RS-422-line driver 3G3FV--PPGD2
for vector control, 300 kHz, RS-422-line driver 3G3FV--PPGX2
Analog input/output cards analog input card, 10 V, 14 bit resolution 3G3IV--PAI14B
analog input card, 0...10 V, 14 bit resolution 3G3IV--PAI14U
aanalog input card, 2 channel, 0...10 V, 8 bit 3G3IV--PAO08
analog input card, 2 channel, 10 V, 12 bit 3G3IV--PAO12
Digital input/output cards pulse output card, pulse frequency proportional to motor frequency 3G3IV--PPO36F
relay output card, 2 change-over contacts, 250 VAC, 30 VDC, 1 A 3G3IV--PDO02C
digital input card, 8 bit, BCD or binary 3G3IV--PDI08
digital input card, 8 bit, BCD or binary 3G3IV--PDI16H2
Consoles and cables copy unit 3G3FV--PJVOP135
programming console 3G3FV--PJVOP130E
extension cable for copy unit 3G3FV--PW5101
extension cable for programming console 3G3FV--PCN125
extension cable for programming console 3G3FV--PCN325
programming cable to PC 3G3FV--PCNDW225N
Adapters adapter for front panel assembly of programming console, fixed assembly 3G3FV--PDACT--AD
adapter for front panel assembly of programming console, removable 3G3FV--PDACT--BD

53
3G3FV inverter
Accessories (continued)

Other accessories
Field bus cards device net 3G3FV--PDRT1--SIN
Special applications master slave speed control of 2 axes, 300 kHz, 3G3FV--PGW2
RS-422-line driver (VSG10012 required)
brake management dependent on current and three-phase current Crane software
speed control dependent on load VSG10514
software for high-speed drives 1000 Hz software
VSG10511

Programming accessories

PC programming Description Cable length Product number


Programming software under WINDOWS -- SYSDRIVE Configurator

Connecting cable 2m 3G3FV--PCNDW225N

54
3G3FV inverter
Technical data

Output data Max. output voltage three-phase: 380/400/415/440/460 V (proportional to input voltage)
Output frequency 0,1 Hz to 400 Hz programmable
Supply Rated input voltage and frequency three-phase 380/400/415/440/460 V, 50/60 Hz
Allowed voltage variation +10%, --15%
Allowed frequency variation 5%
Control functions Type of control sinusoidal pulse width modulation (PWM)
Starting torque 150% at 0 rpm (with incremental encoder)
Speed adjustment range 1:1000 (with incremental encoder)
Speed constant 0,2% (0.02% with incremental encoder)
Speed response 5 Hz (30 Hz with incremental encoder)
Torque limit adjustable (with parameter, 4 values can be set)
Torque precision 5%
Torque response 40 Hz (with incremental encoder)
Output frequency range 0,0-400 Hz
Frequency precision digital default: 0,01%
analog default: 0,1%
Frequency resolution digital operator reference: (0,01 Hz (under 100 Hz) 0,1 Hz (over 100 Hz)
analog reference: (0,03 Hz / 60 Hz (11 Bit + Code)
Output frequency resolution 0.001 Hz
Overload capacity 150% of the output rated current for 1 minute
200% for 1 s
Frequency reference --10 to 10 V, 0 to 10 V, 4 to 20 mA
Acceleration/deceleration 0,0 to 6000 s (can be programmed independently, 4 values can be set)
Braking torque approx. 20% (150% with braking resistor)

Protective Undervoltage stops when main circuit DC voltage is approx. 380 V


functions
Momentary power interruption ridethru immediate stop after failure of longer than 15 ms (standard adjustment)
continuous operation for 2 s on voltage failure (standard)
Cooling fin overheating protection by thermistor
Stall prevention Stall prevention during the acceleration/deceleration phase, and also during
constant frequency operation possible
Earth fault protection by electronic circuit
Charge indicator the charge indicator lights up until the intermediate circuit voltage falls under 50 V
Protection against motor overload thermo-electronic protection against overload
Short-time excess current for the duration of 1 s at 200% of the rated current the motor runs down freely
Fuse short the motor runs down to a halt
Overload after 1 minute at 150% of the rated current the motor runs down to a halt
Overvoltage stops when maincircuit DC voltage is approx. 820 V
Ambient conditions Ambient temperature --10C to +45C (open chassis type)
Air humidity 90% RH (without condensation)
Storage temperature --20C to +60C
Place of assembly inside ( protected against corrosive gases and dust)
Vibrations 1 G for oscillations of less than 20 Hz, up to 0.2 G for oscillations from 20 to 50 Hz

55
3G3FV inverter
Connections diagram

3G3FV, 3 x 400 VAC, 0,4...15 kW

DC reactor
(optional)
380...460 VAC, 50/60 Hz Braking resistor
three-phase (optional)

Line Line
fuse contactor Line filter +1 +2 -- B1 B2

R U
S V M
T W
3--phase

PNP connection NPN connection 21

Forwards-Start/-Stop Forwards-Start/-Stop Multifunction


1 1 analog output 1
Reverse-Start/-Stop Reverse-Start/-Stop 0...10 V
2 2 23
Multifunction input 1 Multifunction input 1
3 3 Multifunction
Multifunction input 2 Multifunction input 2 analog output 2
4 4 0...10 V
Multifunction input 3 Multifunction input 3 22
5 5 Analog output
Multifunction input 4 Multifunction input 4 0V
6 6
Multifunction input 5 Multifunction input 5
7 7
Multifunction input 6 Multifunction input 6 Interference signal relay
8 8 18
Fault output (NO)
36 11
24 V 19
Fault output (NC)
35 35 20
Common
11 36
0V 24 V
9
E Multifunction contact
10 output (relay)
Auxiliary voltage 15 V, 20 mA 15

Main ref. value input 13


0...10 V
Multifunction analog 14
output 1 4...20 mA
25
Multifunction analog 16 Multifunction output 1
output 2 0...10 V (open collector)
27
17
Analog input common 0V

Auxiliary voltage 33
--15 V, 20 mA
26
40 (R+) Multifunction output 2
Serial interface 41 (R--) 37 (open collector)
RS--485/--422
(shielded in pairs) 42 (S+)
43 (S--) E

56
3G3FV inverter
Connections diagram (continued)

3G3FV, 3 x 400 VAC, 18,5...300 kW

380...460 VAC, 50/60 Hz


three-phase

Line Line
fuse contactor Line filter
R U
S V M
T W
3--phase

PNP connection NPN connection 21

Forwards-Start/-Stop Forwards-Start/-Stop Multifunction


1 1 analog output 1
Reverse-Start/-Stop Reverse-Start/-Stop 0...10 V
2 2 23
Multifunction input 1 Multifunction input 1
3 3 Multifunction
Multifunction input 2 Multifunction input 2 analog output 2
4 4 0...10 V
Multifunction input 3 Multifunction input 3 22
5 5 Analog output
Multifunction input 4 Multifunction input 4 0V
6 6
Multifunction input 5 Multifunction input 5
7 7
Multifunction input 6 Multifunction input 6 Interference signal relay
8 8 18
Fault output (NO)
36 11
24 V 19
Fault output (NC)
35 35 20
Common
11 36
0V 24 V
9
E Multifunction contact
10 output (relay)
Auxiliary voltage 15 V, 20 mA 15

Main ref. value input 13


0...10 V
Multifunction analog input 1 14
4...20 mA
25
Multifunction analog input 2 16 Multifunction output 1
0...10 V (open collector)
27
17
Analog input common 0V

Auxiliary voltage 33
--15 V, 20 mA
26
40 (R+) Multifunction output 2
Serial interface 41 (R--) 37 (open collector)
RS--485/--422
(shielded in pairs) 42 (S+)
43 (S--) E

57
3G3FV inverter
Technical documentation

English Product Title Product number


documentation
3G3FV User Manual I516--E1--1

SYSDRIVE INVERTER
3G3FV/3G3HV Installation Manual I520--E1--1
3G3FV--PRT1--S/W Devicenet User Manual I525--E1--1

OPERATION MANUAL

Dimensions (mm)

Inverter
3G3FV--A4_, 400 V, three-phase, up to 15 kW

B B1 H H1 T Weight Product
kg number
140 126 280 266 180 3 004--CUE
007--CUE
140 126 280 266 180 4,5 015--CUE
022--CUE
037--CUE
040--CUE
200 186 300 285 205 6 055--CUE
075--CUE
H1 H
250 236 380 365 225 11 110--CUE
150--CUE

B1 T

58
3G3FV inverter
Dimensions (mm) (continued)

Inverter
3G3FV--B4_, 400 V three-phase, >15 kW

B B1 H H1 T Weight Product
kg number
325 275 450 435 285 27 185--CUE
325 275 450 435 285 27 220--CUE
325 275 625 610 285 44 300--CUE
325 275 625 610 285 44 370--CUE
625 610 285 44 H1 H
325 275 450--CUE
455 350 820 795 350 79 550--CUE
455 350 820 795 350 80 750--CUE
575 445 925 895 375 135 11K--CUE
575 445 925 895 400 145 16K--CUE
950 * 1450 1400 435 * 18K--CUE
B1 T
950 * 1450 1400 435 * 22K--CUE
B
960 * 1600 1550 455 * 30K--CUE
* on demand

Line filter
3G3FV--PFI_, 400 V, single phase, footprint type up to 15 kW

B B1 H H1 T Product
number
143 90 320 310 40 4012E
213 150 350 330 40 4025E
266 200 435 415 55 4040E
H1 H

B1

B T

3G3FV--PFI_, 400 V, three-phase from 15 kW

B B1 H H1 T Product
number
140 106 270 258 90 4060--E
180 146 350 338 90 4100--E
200 166 420 408 130 4120--E
200 166 420 408 130 4150--E H1 H
200 166 480 468 160 4180--E
200 166 480 468 160 4280--E
250 170 567 560 205 4450--E

B1

B T

59
3G3FV inverter

60
Inverters
Selection Guide

Omron Europe B.V. - Wegalaan 67-69 - P.O. Box 13 - 2130 AA Hoofddorp - The Netherlands - Phone: +31 23 568 13 00 - Fax: +31 23 568 13 88 - www.eu.omron.com

Austria Denmark Germany The Netherlands Portugal Switzerland


+43 1 801900 +45 4344 0011 +49 2103 203-3 +31 23 568 1100 +351 21 942 94 00 +41 41 748 1313

Belgium Finland Hungary Norway Spain Turkey


+32 2 466 2480 +358 9 5495 800 +36 1 350 9532 +47 22 65 7500 +34 91 377 7900 +90 126 326 2980/1/2

Czech France Italy Poland Sweden United Kingdom


+42 0 2 6731 1254 +33 1 49 74 70 00 +39 02 32 681 +48 22 645 78 60 +46 8 632 3500 +44 181 450 4646

Cat. No. X201-E2-02

You might also like