0% found this document useful (0 votes)
59 views2 pages

Appendix: Table 1.1 Maximum Harmonic Current Distortions

The document contains two tables that provide technical specifications and modeling parameters for solid oxide fuel cell (SOFC) systems. Table 1 lists allowable harmonic current distortion levels relative to the fundamental based on harmonic order. Table 2 lists parameter names, values, and descriptions used in an SOFC system mathematical model, including rated power, operating temperature, electrode area, and time constants for fuel gas components.

Uploaded by

SudheerKumar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
59 views2 pages

Appendix: Table 1.1 Maximum Harmonic Current Distortions

The document contains two tables that provide technical specifications and modeling parameters for solid oxide fuel cell (SOFC) systems. Table 1 lists allowable harmonic current distortion levels relative to the fundamental based on harmonic order. Table 2 lists parameter names, values, and descriptions used in an SOFC system mathematical model, including rated power, operating temperature, electrode area, and time constants for fuel gas components.

Uploaded by

SudheerKumar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

APPENDIX

Table 1.1 Maximum Harmonic Current Distortions

Harmonic order Allowable level relative to fundamental

(Odd harmonics) in percentage

< 11th 4%

< 11th to < 17th 2%

< 17th to 23rd 1.5%

< 23rd to < 35th 0.6%

35th or greater 0.3%

Total Harmonic Distortion 5%

Table 1.2 Technical Specifications of IEEE Std. 1547

Specifications Descriptions

Voltage 0.88 1.10 per unit

Frequency 59.3 60.5 Hz

Voltage Flicker Imperceptible. IEEE 519 1992 [B5]

DC Injection Less than 0.5%

Harmonics TDD < 5%

Islanding Must be detected within 2 sec.

Synchronization Must cause voltage fluctuation < 5%

Isolation Device Upon request of the area EPS

Parallel Device Capable of withstanding up to 220%

Voltage Rating of the system rating voltage

164
Table 2.2: Parameters representation and values in SOFC system model: [58]

Symbol Parameter Value Symbol Parameter Value


Representation Representation

Prated Rated Power 100 kW H2 Response time for 26.1 sec


Hydrogen

Pref Reference Power 100kW H 2O Response time for 78.3 sec


Water

T Operating 1273 K O 2 Response time for 2.91 sec


temperature Oxygen

F Faradays constant 96487 C/mol r Ohmic resistance 0.126

R Universal gas 8.314 J/(mol m Mass transportation 1 x 10-3


constant K) constant

E0 Ideal standard 1.18 V n Mass transportation 8 x 10-3


potential constant

Umax Maximum fuel 0.9 A Electrode area 0.5 m2


utilization

Umin Minimum fuel 0.8 B Tafel line constant 0.002


utilization

Uopt Optimum fuel 0.85 Tf Fuel system response 5.0sec


utilization time

KH 2 Valve molar constant 8.43 x 104 Te Electrical response time 0.8 sec
for Hydrogen kmol (S atm)

K H 2O Valve molar constant 2.81 x 104 rH_O Hydrogen Oxygen 1.145


for Water kmol (S atm) ratio

KO 2 Valve molar constant 2.52 x 104 Kr Constant, Kr N0 4F -


for Oxygen mol (S atm)

165