Sikaplan-Sgma 2.0 PB Eng

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

Roofing

Product Data Sheet


Edition 03.2009
Identification no. 02 09 01 01 124 0 200000
Version no. 03

Sikaplan-SGmA 2.0 (Trocal SGmA 2.0 mm)


Polymeric membrane for roof waterproofing


Sikaplan -SGmA 2.0 (Trocal SGmA 2.0 mm) is a multi-layer, synthetic roof
Product waterproofing sheet based on premium-quality polyvinyl chloride (PVC) with inlay of
Description glass non-woven according to EN 13956.
Uses Roof waterproofing membrane for roofs with ballast (e.g. gravel, concrete slabs,
green roof (intensive, extensive), terraces with pedestrian traffic):
 Loose laid with ballast
 Green roofs
 Utility roofs
Characteristics /  High resistance to ageing
Advantages  Resistant to all common environmental influences
 High resistance to mechanical influences
 Resistant to micro-organisms
 High tensile strength
 High dimensional stability
 Excellent flexibility in cold temperatures
 High water vapour permeability
 Outstanding weldability
 Resistance against weathering during installation period
 Recyclable
Approval / Standards  Polymeric sheets for roof waterproofing according to EN 13956, certified by
notified body 1213-CPD-4125/4127 and provided with the CE-mark.
 Reaction to fire according to EN 13501-1.
 Root penetration resistance tested according to FLL-Test Procedure.
 Official Quality Approvals and Agrement Certificates and approvals.
 Monitoring and assessment by approved laboratories.
 Quality Management system in accordance with EN ISO 9001/14001.
 Production according to Responsible Care policy of Chemical Industry.
Appearance / Colours Surface: slightly structured
Colours:
Top surface: beige
Bottom surface: beige
Packaging Packing unit: 9 or 15 rolls per pallet
Roll length: 15.00 m
Roll width: 2.00 m
Roll weight: 75.00 kg
Storage Conditions / Rolls must be stored in a horizontal position on pallet and protected from direct
Shelf-Life sunlight, rain and snow. Product does not expire during correct storage.

Sikaplan-SGmA 2.0 (Trocal SGmA 2.0 mm) 1/5


Technical Data
Product Declaration EN 13956
Visible defects Pass EN 1850-2
Length 15.00 m (- 0 % / + 5 %) EN 1848-2
Width 2.00 m (- 0.5 % / + 1 %) EN 1848-2
Straightness 30 mm EN 1848-2
Flatness 10 mm EN 1848-2
Effective thickness 2.0 mm (- 5 % / + 10 %) EN 1849-2
Mass per unit area 2.5 kg/m (- 5 % / + 10 %) EN 1849-2
Water tightness Pass EN 1928
Effects of liquid EN 1847
chemicals, including
water On request
Reaction to fire E EN ISO 11925-2, classification to EN 13501-1
Joint shear resistance 500 N/50 mm EN 12317-2
Water vapour EN 1931
properties 20'000
Tensile stress EN 12311-2
longitudinal (md)
1)
9.5 N/mm
8.5 N/mm
2)
transversal (cmd)
Elongation EN 12311-2
longitudinal (md)
1)
200 %
200 %
2)
transversal (cmd)
Resistance to impact EN 12691
hard substrate 1000 mm
soft substrate 1250 mm
Resistance to static load EN 12730
soft substrate 20 kg
rigid substrate 20 kg
Resistance to root EN 13948
penetration Pass
Dimension stability EN 1107-2
longitudinal (md)
1)
|0.3| %
2)
transversal (cmd) |0.3| %
Foldability at low EN 495-5
temperature -25 C
1)
md = machine direction
2)
cmd = cross machine direction

Sikaplan-SGmA 2.0 (Trocal SGmA 2.0 mm) 2/5


System
Information
System Structure Ancillary products according to local price list:
Sikaplan -18 D unreinforced sheet for detailing

Sikaplan -S 1.5 (Trocal S 1.5 mm) unreinforced sheet for detailing


Sikaplan -SG 1.5 (Trocal SG 1.5 mm) or Sikaplan -15 G roofing sheet for

exposed connections and flashings


Moulded corner pieces, prefabricated corners and pipe flashings
Sika-Trocal Metal Sheet Type S

Sika-Trocal Cleaner 2000


Sika-Trocal Cleaner L 100


Sika-Trocal Welding Agent


Sika-Trocal Seam Sealant


Sika-Trocal C 733 (Contact adhesive)


Sika-Trocal CV 705/733 (Thinner for Sika-Trocal C 733)


Application Details
Substrate Quality The substrate surface must be uniform, smooth and free of any sharp protrusions or
burrs, etc.

Sikaplan -SGmA 2.0 (Trocal SGmA 2.0 mm) must be separated from any
incompatible substrates by an effective separation layer to prevent accelerated
ageing. Prevent direct contact with bitumen, tar, fat, oil, solvent containing materials
and other plastic materials, e.g. expanded polystyrene (EPS), extruded polystyrene
(XPS), polyurethane (PUR), polyisocyanurate (PIR) or phenolic foam (PF) as this
could adversely affect the product properties.
Application
Conditions / Limits

Temperature The use of Sikaplan -SGmA 2.0 (Trocal SGmA 2.0 mm) membranes is limited to
geographical locations with average monthly minimum temperatures of -25 C.
Permanent ambient temperature during use is limited to +50 C.
Compatibility Not compatible with direct contact to other plastics, e.g. EPS, XPS, PUR, PIR, PF.
Not resistant to tar, bitumen, oil and solvent containing materials.
Resistance Not applicable for permanent exposure to UV irradiation.

Sikaplan-SGmA 2.0 (Trocal SGmA 2.0 mm) 3/5


Installation
Instructions
Installation Method / Installation procedure:

Tools According to the valid installation instructions of manufacturer for Sikaplan SGmA

(Trocal SGmA)-types for ballasted roof system.
Fixing Method:
Loosely laid and covered with ballast. Mechanical fixing at the roof perimeter is
recommended to keep membrane in place.
The roof waterproofing membrane is installed by loose laying and covered with
ballast according to local wind load situation. If ballast weight is insufficient to
restrain against wind uplift the membrane may be fixed mechanically in seam
overlap or independent from overlap.
Welding Method:
Overlap seams are welded by electric hot welding equipment, such as manual hot
air welding machines and pressure rollers or automatic hot air welding machines
with controlled hot air temperature capability of minimum 600 C.

Recommended type of equipment: LEISTER TRIAC PID for manual welding


LEISTER VARIMAT for automatic welding
Welding parameters including temperature, machine speed, air flow, pressure and
machine settings must be evaluated, adapted and checked on site according to the
type of equipment and the climatic situation prior to welding works. The effective
width of welded overlaps should be minimum 20 mm.

If local weather conditions allow cold welding of sheet overlaps with Sika-Trocal

Welding Agent, it is permitted for Sikaplan -SGmA 2.0 (Trocal SGmA 2.0 mm)
system with ballast. The effective width of welded overlap by cold welding must be
30 mm.
The seams must be mechanically tested with screw driver or steel needle to ensure
the integrity/completion of the weld. Any imperfections must be rectified by hot air
welding.

Cold welded seam edges must be sealed by Sika-Trocal Seam Sealant after
testing.
Notes on Installation / Installation works must be carried out only by Sika instructed contractors for roofing.
Limits
Temperature limits for the installation of the membrane:
Substrate temperature: -25 C min. / +60 C max. for hot air welding
+5 C min. / +60 C max. for cold welding
Ambient temperature: -15 C min. / +60 C max. for hot air welding
+5 C min. / +60 C max. for cold welding
Installation of some ancillary products, e.g. contact adhesives/thinners is limited to
temperatures above +5 C. Please refer to the respective Product Data Sheets.
Special measures may be compulsory for installation below +5 C ambient
temperature due to safety requirements in accordance with national regulations.

Sikaplan-SGmA 2.0 (Trocal SGmA 2.0 mm) 4/5


Value Base All technical data stated in this Product Data Sheet are based on laboratory tests.
Actual measured data may vary due to circumstances beyond our control.

Local Restrictions Please note that as a result of specific local regulations the performance of this
product may vary from country to country. Please consult the local Product Data
Sheet for the exact description of the application fields.

Ecology, Health The product does not fall within the EC-regulation of hazardous goods.
As a result, a material safety data sheet following EC-Guideline 91/155 EWG is not
and Safety needed to bring the product to the market, transport or use it.
Information The product does not damage the environment when used as specified.
Protective Measures Fresh air ventilation must be ensured, when working (welding) in closed rooms.
Local safety regulations must be observed.
Transportation Class The product is not classified as hazardous good for transport.
Disposal The material is recyclable. Disposal must be according to local regulations. Please
contact your local Sika sales organisation for more information.

Sika Sverige AB
Domnarvsgatan 15
Box 8061 Tel. +46 8 621 89 00
SE-163 08 Spnga Fax +46 8 621 89 89
Sverige www.sika.se

Sikaplan-SGmA 2.0 (Trocal SGmA 2.0 mm) 5/5

You might also like