This document contains the solutions to 17 multiple choice questions related to structural design codes and concepts. The questions cover topics like limit states, steel alloys, partial safety factors, design wind loads, buckling, material properties and bolted connection design.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
336 views
Week 1 Assignment 1 Solution
This document contains the solutions to 17 multiple choice questions related to structural design codes and concepts. The questions cover topics like limit states, steel alloys, partial safety factors, design wind loads, buckling, material properties and bolted connection design.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2
Week 1 Assignment 1 Solution
Q.1 Which of the following is considered as limit state of strength?
Answer:- (c) Fracture see clause 5.1.2 of IS 800: 2007 Q.2 Steel is an alloy which mainly contains Answer:- c) iron and carbon see slide no-4, lecture 2 (steel as a structural material) Q.3 What is the partial safety factor for dead load when it contributes to the stability of the structure against overturning? Answer:- (d) 0.9 see clause 5.5.1.1(c) of IS 800: 2007 Q.4 Which factor is denoted by k1 in the calculation of design wind speed? Answer:- (c) Probability factor see clause 5.3 of IS 875 (part-3): 2007 Q.5 What is the minimum pitch distance according to IS 800:2007 if d is the bolt diameter? Answer:- (d) 2.5d see clause 10.2.2 of IS 800: 2007 Q.6 What is the hole diameter for a bolt of 25 mm diameter? Answer:- (d) 28 mm see Table-19 of IS 800: 2007 Q.7 What is the maximum distance between two consecutive bolts (in tension) if the plate thickness is 10 mm? Answer:- (a) 160 mm see clause 10.2.3.2 of IS 800: 2007 The distance between the centres of two adjacent fasteners (pitch) in a line lying in the direction of stress, shall not exceed 16t or 200 mm, whichever is less, in tension members. So maximum distance = 1610 = 160 mm Q.8 What is the design wind pressure if the design wind speed is 50 m/s2? Answer:- (a) 1.5 kN/m2 As per clause 5.4; IS 875 (part 3) -1985 Design wind pressure, = 0.62 = 0.6 502 = 1500 N/m2 = 1.5kN/m2 Q.9 IS: 800-2007 limits the values of width-to-thickness ratios of the elements of a steel section to place a check on Answer:- (d) local buckling Q.10 The necking of the steel section during tensile test takes place Answer:- (c) after reaching ultimate tensile stress Necking is a mode of tensile deformation where relatively large amounts of strain localize disproportionately in a small region of the material. The resulting prominent decrease in local cross-sectional area provides the basis for the name "neck". Q.11 Partial safety factor for material resistance governed by ultimate stress is taken in IS 800:2007 as Answer:- (a) 1.25 see Table-5 of IS 800: 2007 Q.12 Partial safety factor for resistance of field fabricated welds is taken in IS 800:2007 as Answer:- (c) 1.5 see Table-5 of IS 800: 2007 Q.13 The partial safety factor for DL + LL + CL in limit state of strength is taken as Answer:- (c) 1.5 The question was not appropriate. This question will not be considered for evaluation. Q.14 According IS 875 (part-3)-1987 the numbers of zone are Answer:- (d) 6 See IS 875 (part 3) -1985 Q.15 The mechanical properties of steel largely depend on its Answer:- (d) All the above See slide no-4, lecture 2 Q.16 The minimum edge distance in member with rolled edge (for bolted connection) is approximately Answer:- (b) 1.5 hole diameter See 10.2.4.2 of IS 800 :2007. Q.17 Youngs modulus of steel is Answer:- (a) 2105 MPa See any book of steel structures or any steel table.