Steel Sketch With Problem
Steel Sketch With Problem
Steel Sketch With Problem
IMSC- [email protected]/m
h=400, b=100, tf=15.3, tw=8.6
Column with Double lacing :
Build up column consists of 2 ISHB-300@ 63kg/m spaced at 350mm c/c
Provide double lacing 60mm*10mm
Inclination of lacing-45degree
Provide 8mm size fillet weld for a length 50mm on either side.
Soln: ISHB- 300@63Kg/m
h=300, b=250, tf=10.6, tw=9.4
Column bases
Slab base:
ISHB 400 @77.4 kg/cm2 is supported on slab base.
Size of the slab base 900mm*500mm*30mm
Size of the concrete base 1.5*1.5*1m
Size of the cleat angle ISA 150*115*10mm
Use 4- #24 di bolts between angle and column flange.
Provided 4 #20 dia anchor bolts.
Column with battens :
Build up columns consists of 2 ISMC 300 @ 35.8kg/m placed face to
face or toe 150m apart.
The column is connected to battens using welded connection size of the
battens = 250mm* 10mm spacing @ 700mm c/c.
Column splices
1. Same column size: Column splice is provided for two columns
Ishb-250 @ 54.7 kg/m
a. Flange splice: 250mm*400*10mm
No of rivets 6 # 18 for each column on each side with pitch=
60mm and E.D= 40 mm
b. Web splice: 140mm*160*10mm
No of rivets 4 # 20 for each column
Therefore, B=350 mm
Bearing pressure,
=364.2mm
137200 N
Using 6 mm size fillet weld,
Therefore, l = 175 mm
COLUMNS:
2). The top chord of a bridge truss having an effective length of 3.6m
has a c/s shown. Determine the compressive load this member can carry.
Properties of one channel
ISMC- 200 @ 22.1 Kg/m
area=
Ixx = 1819.3 * 104 mm4
Iyy = 140.4 * 104 mm4
Cyy =21.70 mm
y =132.24 mm
[ ( ) ]
[ ( ) ]
[ ( ) ] [ ]
( )
soln :
[ ] [ ]
[ ( ) ] [ ]
UNIT-4 ROOF TRUSS
Points to remember:
Design totally 4 members(2-outer,2-inner)
Use equal angles
Minimum size of angle- ISA 50mmX5OmmX6mm
For outer members Double angles
Inner members Single angle
Take effective length le=0.85l
Provide a minimum of 2 bolts
Gusset plate thickness is same as angle thickness or more and it is
uniform throughout.
1) Line diagram of a roof truss with external load and forces in each
member along with nature are shown in fig. below. Design various
members of the roof truss along with their end connections with
gusset plate[welded or bolted].
Also design the supports consisting of angles and bearing plate for the
support reaction.
Also design anchor bolts for an uplift of 15KN at each support. Take
M20 concrete for the column. The right support may be considered as
anchoring with sliding provision.
The left support may be considered as only anchoring support.
Draw to a suitable scale
i)Elevation of truss greater than half span
ii)Enlarged view of apex joint of the truss
iii)Enlarged view of the left support joint.
a) Assume fcd=120N/mm2
Area = force/fcd = 360X103/120 = 3000mm2 = 30cm2
b) Connection
Using M20 , property class 5.6 Black Bolt
i) Shear strength
Vdsb = Vnsb/mb [fy/3] No shank
= 113.18KN
Tdn=
311.76X103 = 0.8XAnx410/1.25
An = 1188.1mm2
Increase approximately by 30%
= 1.30X1188.1= 1544.5mm2 = 15.44cm2
b) Connection
Let us try M20 P Class 8.8 HSFG Bolts
Vdsf= Vnsf/ mf = 1/ mf [f.nekhFo]]
mf = 1.25, f=0.55, ne = 2
Kh= 1.0
FO = Ahb.fo = Ahb(0.7fub)
= 0.78 (0.7fub)
= 137.2X103
Vdsf = 1/1.25[(0.55)(2)(1)(13702x103)]
= 120.75KN
No.of bolts = 311.76/120.75 = 3
= 1.4-0.076( ) )
ISA 80X80X10mm
Area = 1505 mm2
vv = 15.5 mm
= 2.13
= = 0.09
e = = 1.86
From Page 34
Fcd=
[ ]
= 50.35 N/mm2
b) Connection
MA=0, RA*25-150*12.5-275*24=0
RA=339kn
There are two wheels at each end of crane bridge .
Therefore load on each wheel = 12.5*169.5=211.87kn
Take 212kn
b) Now consider gantry girder:
The arrangement of wheel load for maximum BM is, the mid span is
equi-distance from resultant of two wheel loads and any one load.
ROLLING LOAD METHOD
later take moment under the wheel load 4 which is very close to mid
span.
md=0, rc*8-212*1.375-212(1.375+1.75+1.75)=0
RC=165.63kn
Therefore Mmax=RC*3.125=165.63*3.125=517.6kn
Therefore factored moment M=776.4kn-m
d) Trial section:
The trial section is selected based on deflection condition .
The permissible deflection for electricity operated crane (upto
50t=500KN)
But actual deflection
2
= 485.65 N/mm
H2=2.5[40+14.7] = 136.75mm
Fw=(100+136.75)x9.9x250/1.10
Fw=532.38KN > 496.88 KN(safe)
h) Check for buckling of web
Buckling strength = (b1+n1)twXfcd
B1=100mm
H1=284.9mm=exx
Tw=9.9mm
=kL/ = le/min=0.7d/yy
= 3.44
From table 9(c) page 42
Fcd=227 N/mm2
Buckling strength = (100+284.9)X9.9X227
= 865X103N > 496.88KN (Safe)
Hence the above section can be used as a gantry girder.
Connection
a) No. of bolts = n =
n= = 8 per line
b) Check
i) Fa = P/N = 496.88X103/8X4
= 15.52KN
= = 190.39
2= 520X103 mm2
Fm= M/2 = 36.38KN
Resultant = R= cos
R= 44.82KN < Bolt value 60.38KN (Safe)