3.0 Pilecap Design

The document summarizes the pile cap design for micropiles connecting to a pile head. Ties running around the pile head are designed to resist concrete breakout and punching shear. Calculations show the tie resistance of 1152 kN exceeds the maximum axial compression and tension loads on the piles. The pullout resistance of 3776 kN from the DYWIDAG bar embedded in the pile head plate also exceeds the maximum axial tension load on a pile.

Uploaded by

pektoph
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
62 views2 pages

3.0 Pilecap Design

The document summarizes the pile cap design for micropiles connecting to a pile head. Ties running around the pile head are designed to resist concrete breakout and punching shear. Calculations show the tie resistance of 1152 kN exceeds the maximum axial compression and tension loads on the piles. The pullout resistance of 3776 kN from the DYWIDAG bar embedded in the pile head plate also exceeds the maximum axial tension load on a pile.

Uploaded by

pektoph
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

3.

0 PILECAP DESIGN

3.1 PILEHEAD ANCHORAGE AND PUNCHING SHEAR DESIGN

Pile Head Tension/Compression Resistance

Concrete Breakout & Punching Shear

4 legs 15M -100 Tie is running on all micropile head to take care of concrete breakout and punching shear and concrete part
resistance is neglected.
The concrete breakout/punching failure surface interests min 4-15M ties, each tie has 4 legs
2 -3
Tie resistance = 0.9 x400 x 4(tie) x 4(leg) x 200mm x10 = 1152 kN
Max factored batter pile axial compression (pile No 11) Cf = 532kN x1.5 = 798 kN < 1152 kN --> OK
Max factored batter pile axial tension (pile No 5) Tf = 402kN x1.5 = 603 kN < 1152 kN --> OK

14 of 60
DYWIDAG Bar Pullout Resistance

2 2
1.75 DYWIDAG bar Ase =2.25 in = 1452 mm
2 2
Head Plate PL38x150x150 --> Abh = 150 -1452 = 21048 mm
Max factored batter pile axial tension (pile No 5) Tf = 402kN x1.5 = 603 kN

Anchor Pullout Resistance A23.3-04


Single bolt pullout resistance Npr = 8 Abh c fc' R = 3776.0 [kN] D.6.3.4 (D-16)
Ncpr = nt c,p Npr = 3776.0 [kN] D.6.3.1 (D-15)
Seismic design strength reduction = x 1.0 not applicable = 3776.0 [kN] D.4.3.5
ratio = 0.16 > Nu OK
c,p = 1 for cracked conc D.6.3.6
R = 1.15 for Condition A tension load D.5.4 (c)

15 of 60