0% found this document useful (0 votes)
84 views

Graph

This document presents experimental data from tests conducted on an open pan evaporator and a double pipe heat exchanger operating in co-current and counter-current configurations. Tables of temperature, heat flux, heat transfer coefficient and other variables are reported for varying process conditions in the evaporator and heat exchanger like inlet temperatures, mass flow rates, and time. Graphs are also shown plotting variables like temperature, heat transfer coefficient and evaporation rate against time and each other.

Uploaded by

devilturn70
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
84 views

Graph

This document presents experimental data from tests conducted on an open pan evaporator and a double pipe heat exchanger operating in co-current and counter-current configurations. Tables of temperature, heat flux, heat transfer coefficient and other variables are reported for varying process conditions in the evaporator and heat exchanger like inlet temperatures, mass flow rates, and time. Graphs are also shown plotting variables like temperature, heat transfer coefficient and evaporation rate against time and each other.

Uploaded by

devilturn70
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

Open pan evaporator

open pan evaporator


no. of obs. Time P=10 P=20 P=30
psig psig psig
(sec) T ( C) T ( C) T ( C)
1 60 68 64 60
2 120 78 74 76
3 180 84 80 84
4 240 88 86 92
5 300 90 92 94
6 360 92 96 98

Dimensionless temperature overal heat transfer coefficient (U)


no. of Time P=10 P=20 P=30 no. of Time P=10 P=20 P=30
obs. psig psig psig obs. pisg psig psig
(sec) T/Ts T/Ts T/Ts (sec) U U U
1 60 0.591304 0.556522 0.521739 1 60 3447 2430 2195
2 120 0.678261 0.643478 0.66087 2 120 2521 2129 1972
3 180 0.730435 0.695652 0.730435 3 180 2172 2259 2042
4 240 0.765217 0.747826 0.8 4 240 2004 1913 2197

overall heat transfer coefficent vs time


4000
3500
3000
U(j/m2.Csec

2500
2000
1500
1000
500
0
0 50 100 150 200 250 300
time (Sec

p=10 p=20 p=30


Henchley eq.

henchley equation
no Temp ( C ) Rate of evp.
obsv. (g/min)
1 45 0.2
2 55 0.4
3 65 0.9

Partial vapour
pressure pressure water
pw(mm Hg) pw* (mm Hg) ln (Pw*-Pw) ln (W)
30.4 71.97 3.73 -1.61
31.16 118.22 4.47 -0.92
31.92 187.81 5.05 -0.1

Rate of evp. vs temp


1
0.9
0.8
Rate of evp. (g/min)

0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
0 10 20 30 40 50 60 70
Temp ( C )
ln (W) vs (Pw*-Pw)
0
3 3.5 4 4.5 5 5.5

-0.5

-1
ln (W)

-1.5

-2

-2.5

-3
ln (Pw*-Pw)

Viscosity

% age composition of unknown sample


no % % water efflux
obs. alcohol time
1 0 100 11.11
2 20 80 15.21
3 50 50 31
4 80 20 48.32
5 unknown unknown 35.21

% composition alcohol
90
80
70
60
% alcohol

50
40
30
20
10
0
0 10 20 30 40 50 60
Time(s)
ln Va vs Temp
0.4

0.2

0
0 10 20 30 40 50 60 70 80 90
-0.2
ln Va

-0.4

-0.6

-0.8

-1

-1.2
Temp ( C)

Viscosity Va vs temp
1.4

1.2

0.8
Va

0.6

0.4

0.2

0
0 10 20 30 40 50 60 70 80 90
temp ( C )
Double pipe heat exchanger

Co-current operation

(a) constant hot water flow rate- Co-current operation


cold side hot side
obs. mass flow inlet temp outlet mass inlet outlet
temp flow temp temp
W (Kg/h) t1 t2 W T1 T2
(Kg/h)
1 0.122 34.1 36.5 0.122 45 42.8
2 0.28 34 36 0.122 48 44
3 0.3 34 35.8 0.122 49 44.5

(b)constant cold water flow rate- Co-current operation


cold side hot side
obs. mass flow inlet temp outlet mass inlet outlet
temp flow temp temp
W (Kg/h) t1 t2 W T1 T2
(Kg/h)
1 0.12 34.1 36 0.12 45.3 43
2 0.12 34 37 0.16 48.6 44.8
3 0.12 34 37 0.17 48 44

( c ) constant hot water flow rate- Co-current operation


obs. 1 2 m Qo heat U0
flux(qo)
C C C watt watt/m^2 watt/m^2 C
1 10.9 6.3 8.3 0.00031 0.003 0.00036
2 1 7.9 10.6 0.000683 0.0066 0.00062
3 1.5 8.7 11.3 0.00063 0.006 0.00053
( d ) constant cold water flow rate- Co-current operation
obs. 1 2 m Qo heat U0
flux(qo)
C C C watt watt/m^2 watt/m^2 C
1 11.3 7 8.97 0.00028 0.0027 0.0003
2 14.5 7.8 10.8 0.0004 0.0039 0.00036
3 14 7 10.09 0.00041 0.004 0.0004

Counter current operation

(a) constant hot water flow rate- Counter current operation


cold side hot side
obs. mass flow inlet temp outlet mass inlet outlet
temp flow temp temp
W (Kg/h) t1 t2 W T1 T2
(Kg/h)
1 0.1 34.1 38 0.122 50.5 48.3
2 0.2 34.1 38.5 0.122 51.3 48.3
3 0.3 34 37 0.122 48.3 48.3

(b)constant cold water flow rate -Counter current operation


cold side hot side
obs. mass flow inlet temp outlet mass inlet outlet
temp flow temp temp
W (Kg/h) t1 t2 W T1 T2
(Kg/h)
1 0.12 34.1 38.5 0.12 50.8 48.5
2 0.12 34.1 39 0.16 51.4 48
3 0.12 34.1 39 0.17 48.5 43.5
( c ) constant hot water flow rate -Counter current operation
obs. 1 2 m Qo heat U0
flux(qo)
C C C watt watt/m^2 watt/m^2
C
1 12.5 14.2 13.33 0.00031 0.003 0.00022
2 12.8 14.2 13.49 0.00042 0.0041 0.0003
3 11.3 14.4 12.79 0.000014 0.00013 0.00001

( d ) constant cold water flow rate-Counter current operation


obs. 1 2 m Qo heat U0
flux(qo)
C C watt watt/m^2 watt/m^2
C
1 12.3 12.2 12.2 0.00032 0.0031 0.00025
2 9 12.4 10.6 0.00063 0.0061 0.00057
3 4.5 9.5 6.6 0.00098 0.0095 0.0014

constant hot water flow rate


0.0007

0.0006

0.0005

0.0004
U

0.0003

0.0002

0.0001

0
0 0.05 0.1 0.15 0.2 0.25 0.3 0.35
flow rate(kg/h
constant hot water flow rate
0.008
0.007
heat flux(watt/m2)

0.006
0.005
0.004
0.003
0.002
0.001
0
0 0.05 0.1 0.15 0.2 0.25 0.3 0.35
flow rate(kg/h)

co-current counter-current

constant hot water flow rate


14

13

12
LMTD

11

10

8
0.1 0.15 0.2 0.25 0.3
Flow rate (kg/h)

countercurrent cocurrent

constant cold water flow rate


0.0006
0.0005
0.0004
0.0003
U

0.0002
0.0001
0
0.11 0.12 0.13 0.14 0.15 0.16 0.17
hot flow rate kg/h

co-current counter
constant cold water flow rate
13
11
9
7
LMTD

5
3
1
-1 0.11 0.12 0.13 0.14 0.15 0.16 0.17 0.18
hot flow rate kg/h

co-current counter

constant cold water flow rate


0.01

0.008
heat flux

0.006

0.004

0.002

0
0.11 0.12 0.13 0.14 0.15 0.16 0.17 0.18
hot flow rate kg/h

co-current conter