4 Digit Programmablev&a Meter
4 Digit Programmablev&a Meter
3 4
Specifications :
l Measuring method TRMS using microcontroller
l Display type RED LED Super Bright Display
4 Digit Programmable l Maximum Display 0-9999 counts (4 Digit)
Overrange Indication -OL-
Ammeter
l
l Under range Indication -UL-
MODEL : SMP35SN l Resolution 0.001 to 1 (depending on CTP)
l Accuracy 0.5% FSD
l Sampling Rate 2.5 Samples/Second
l Maximum Overload 2 times continuous
l Faceplate/Lens Red Antiglare Faceplate with
Annunciators
l Mounting Clamps Sturdy, Derlin (Engineering
plastic)
l VA Burden (Typical) Auxiliary : < 1.5VA
Input : < 0.5VA
l Frequency Response 45-65Hz
l Environmental conditions 0 to 550C, <70% RH (Operation)
-10 to 700C, <70%RH (Storage)
l Dielectric strength 2.5 KV at 50Hz for 1 minute
between Input, Auxiliary & Case
l Impulse withstand 3.5KV, 1.2/50 S.
l Case/Housing Material Black ABS, Dimension as per
DIN 43700
l Connectors Terminal Block : Thermoplastic
(UL 94V-0) With Tin Plated Brass
Terminals
l Display Stability Within 2 digits
l Display Digit Height 0.56" / 14.2mm
l Auxiliary Supply (Dual) 230V AC 10% / 110V AC 10%
@50 Hz
USER MANUAL (V1.2) 2
Terminal Connection Note : If the selected range is 5A then short the jumper J2
Aux. Supply (any one only) provided at front PCB in the meter.
230V AC If the selected range is 1A then open the jumper J2 provided
IN IN 110V at front PCB in the meter. Remove filter plate to open/
(LO) (HI) N AC L L
short J2 jumper.
Meter will display "Ctp". Press "P" key to configure the CT
primary. Meter will display "0001" with right most digit i.e. "1" will
Power ON the meter, meter will display measured readings. be blinking.
Default Factory Setting : Note : In case of 5A range CT primary should be greater
A1 / A5 : A5 (5A Range) than or equal to 5.
CTP : 5 To change digit 0 to 9 use "" Key and to shift left use "" Key.
Programming Mode : Enter required CT primary.
To configure the meter, Press "P" key, the meter will display e.g. If CT being used is 1000/5A user should enter 1000 as
"----". Enter the Password to configure the meter. Password is CT primary. Selected current range should be A 5 (i.e. 5A
"4321". If it is not required to configure the meter press "P" key range).
again, meter will start displaying measured reading. To enter the CT primary with decimal point, press, "" key after
To change digit 0 to 9 use "" Key and to shift left use "" Key. left most digit starts blinking. Now no digit will blink. Press ""
key to change decimal point. Initially decimal point will appear at
e.g. Enter Password "4321".
second digit from right side. Press "" key to shift decimal
Press "" key "---1"
point left side. After decimal point reaches at left most digit if
Press "" key followed by "" key "--11" user presses "" key decimal point will disappear. Press "P"
Press "" key again "--21" Key to enter. Now meter will display the measured values. For
Press"" key followed by "" key "-121" Measured Value > 9999, the LED for "K" (Kilo) will glow.
Press ""key again "-221"
TEST RESULTS :
Press ""key again "-321"
Press ""key followed by "" key "1321" INPUT (5A) 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0
Press ""key again "2321" INPUT (1A) 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Press ""key again "3321"
RESULT UL OK OK OK OK OK OK OK OK OK OK
Press ""key again "4321". Press "P" key to enter setup.
Use "" key to change between "A 1" and "A 5" (1A range or 5A
range). (If entered password is wrong and "P" key is pressed, MECO INSTRUMENTS PRIVATE LTD.
meter will start displaying measured readings.) Plot No. EL-1, MIDC Electronic Zone, TTC Industrial Area, Mahape, Navi Mumbai - 400710 (INDIA)
Press "P" key to enter the desired range. Tel : 0091-22-27673311-16, 27673300 (Board) Fax : 0091-22-27673310, 27673330
3 E-mail : [email protected] Web : www.mecoinst.com 4
15102010
Note : If the selected range is 5A then short the jumper
1A/5A provided at front PCB in the meter.
If the selected range is 1A then open the jumper 1A/5A
provided at front PCB in the meter. Remove filter plate to
open/short 1A/5A jumper. 4 Digit Programmable
Meter will display "Ctp". Press "P" key to configure the CT Ammeter
primary. Meter will display "0001" with right most digit i.e. "1" will
be blinking. MODEL : SMP9635SN
Note : In case of 5A range CT primary should be greater
than or equal to 5.
To change digit 0 to 9 use "" Key and to shift left use "" Key.
Enter required CT primary.
e.g. If CT being used is 1000/5A user should enter 1000 as
CT primary. Selected current range should be A 5 (i.e. 5A
range).
To enter the CT primary with decimal point, press, "" key after
left most digit starts blinking. Now no digit will blink. Press ""
key to change decimal point. Initially decimal point will appear at
second digit from right side. Press "" key to shift decimal
point left side. After decimal point reaches at left most digit if
user presses "" key decimal point will disappear. Press "P"
Key to enter. Now meter will display the measured values. For
Measured Value > 9999, the LED for "K" (Kilo) will glow.
TEST RESULTS : Meter Serial No. ..........................................
INPUT (5A) 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0
INPUT (1A) 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
RESULT UL OK OK OK OK OK OK OK OK OK OK
2 3
SMP9635SN-A : 28-09-2012
start displaying measured readings.)
Press "P" key to configure PT ratio.
Meter will display "0001" with right most digit i.e. "1" will be blinking.
To change digit 0 to 9 use "" Key and to shift left use "" Key.
Enter required PT ratio.
4 Digit Programmable
e.g. if PT is 33KV / 110V then Voltmeter
PT ratio = PT primary / PT secondary. MODEL : SMP9635SN
PT ratio = 33000 / 110 = 300.
To enter the PT ratio with decimal point, press "" key after left
most digit starts blinking. Now no digit will blink. Press "" key to
change decimal point. Initially decimal point will appear at second
digit from right side. Press "" key to shift decimal point left side.
After decimal point reaches at left most digit if user presses ""
key decimal point will disappear. Press "P" to enter. Now meter
will display the measured values. For Measured Value > 9999,
the LED for "K" (Kilo) will glow.
INPUT (V) 0 50 100 150 200 250 300 350 400 450 500
RESULT UL OK OK OK OK OK OK OK OK OK OK
SMP9635SN-V : 28-09-2012