Inconort Contratistas Generales Eirl: Pumping Test - Water Level Data

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Pumping Test - Water Level Data Page 1 of 1

INCONORT CONTRATISTAS Project: Estudio Fuente de Agua Bateria de Pozos

GENERALES EIRL Number: 01


Client: SEDALIB

Location: Barraza - Laredo Pumping Test: IRHS142 Pumping Well: Well 1

Test Conducted by: Ing. J.Sanchez T. Test Date: 18/06/2016 Discharge: variable, average rate 18.903 [l/s]

Observation Well: Well 1 Static Water Level [m]: 1.30 Radial Distance to PW [m]: -

Time Water Level Drawdown


[s] [m] [m]
1 0 1.30 0.00
2 30 1.48 0.18
3 60 1.70 0.40
4 90 1.90 0.60
5 120 2.02 0.72
6 150 2.12 0.82
7 180 2.21 0.91
8 210 2.28 0.98
9 240 2.35 1.05
10 270 2.39 1.09
11 300 2.44 1.14
12 360 2.55 1.25
13 420 2.57 1.27
14 480 2.62 1.32
15 540 2.67 1.37
16 600 2.70 1.40
17 660 2.71 1.41
18 720 2.72 1.42
19 780 2.73 1.43
20 840 2.75 1.45
21 900 2.77 1.47
22 1200 2.83 1.53
23 1500 2.81 1.51
24 1800 2.81 1.51
25 2100 2.84 1.54
26 2400 2.83 1.53
27 2700 2.84 1.54
28 3000 2.83 1.53
29 3300 3.59 2.29
30 3600 3.72 2.42
31 4200 3.73 2.43
32 4800 3.76 2.46
33 5400 3.78 2.48
34 6000 3.81 2.51
35 6600 3.81 2.51
36 7200 3.83 2.53
37 8100 3.84 2.54
38 9000 3.86 2.56
39 9900 3.88 2.58
40 10800 3.90 2.60
41 12600 3.945 2.645
42 14400 3.945 2.645
43 16200 4.51 3.21