0% found this document useful (0 votes)
168 views3 pages

Lateral Pile Analysis Example

This document contains calculations for the axial compressive and tensile resistance of a driven steel pile with a length of 7000mm installed in two soil strata. It determines that the pile has sufficient capacity to resist the design compression and tension loads under two load combinations when accounting for partial resistance factors and a model factor in accordance with Eurocode 7. The pile passes all checks for axial resistance in both compression and tension.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
168 views3 pages

Lateral Pile Analysis Example

This document contains calculations for the axial compressive and tensile resistance of a driven steel pile with a length of 7000mm installed in two soil strata. It determines that the pile has sufficient capacity to resist the design compression and tension loads under two load combinations when accounting for partial resistance factors and a model factor in accordance with Eurocode 7. The pile passes all checks for axial resistance in both compression and tension.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Project Job no.

Fenog Nigeria Limited Calcs for Start page no./Revision

Warri 1
Calcs by Calcs date Checked by Checked date Approved by Approved date
R 08/08/2017

PILE ANALYSIS
In accordance with EN 1997-1:2004 incorporating Corrigendum dated February 2009 and the UK national annex
Tedds calculation version 1.0.00

Pile details
Installation method; Driven
Shape; Euro CHS 762.0x20.0
Length; L = 7000 mm
Material details
Material; Steel
Modulus of elasticity; E = 210 kN/mm2
Geometric properties
Pile section end is closed; No
Plugging action assumed for bearing; No
Pile section depth; h = 762 mm
Bearing area; Abearing = A = 0.047 m2
Pile perimeter; Perimpile = h = 2.394 m
Moment of inertia; I = Iy = 321083 cm4

Fd
7000 mm
10000 mm

qsk1 = 25 kN/m 2
qbk1 = 0 kN/m 2

Stratum 2

qski = Characteristic value, shaft resistance, q bki = Characteristic value, base

Stratum details
Stratum Geomaterial Thickness, tstratai Characteristic value, Characteristic value,
(mm) base, qbki shaft, qski
(kN/m2) (kN/m2)
1 Cohesive 10000 - 25
2 Cohesive 5000 346 20.8

Action details
Characteristic perm. unfav. action, compression; Gc,k,unfav = 200 kN
Project Job no.

Fenog Nigeria Limited Calcs for Start page no./Revision

Warri 2
Calcs by Calcs date Checked by Checked date Approved by Approved date
R 08/08/2017

Characteristic perm. fav. action, compression; Gc,k,fav = 0 kN


Characteristic variable unfav. action, compression; Qc,k = 0 kN
Characteristic perm. unfav. action, tension; Gt,k,unfav = 200 kN
Characteristic perm. fav. action, tension; Gt,k,fav = 0 kN
Characteristic variable unfav. action, tension; Qt,k = 0 kN
Geotechnical partial and model factors:
Design approach 1:
Model factor on axial resistance; model = 1.20
Permanent unfavourable, A1 (Table A.3); G,unfav,A1 = 1.35
Permanent favourable, A1 (1); G,fav,A1 = 1.00
Variable unfavourable, A1 (Table A.3); Q,A1 = 1.50
Permanent unfavourable, A2 (Table A.3); G,unfav,A2 = 1.00
Permanent favourable, A2 (Table A.3); G,fav,A2 = 1.00
Variable unfavourable, A2 (Table A.3); Q,A2 = 1.30

Characteristic axial resistance


Characteristic axial base resistance; Rbk = Abearing qbk = 0 kN
Characteristic axial shaft resistance per stratum
Stratum 1; Rsk1 = qsk1 Perimpile (L - Dstrata1) =418.9 kN
Characteristic total axial shaft resistance; Rsk = Rsk1 = 418.9 kN
Axial compressive resistance
Load combination 1: A1 + M1 + R1
Design compression action; Fc,d,C1 = G,unfav,A1 Gc,k,unfav - G,fav,A1 Gc,k,fav + Q,A1 Qc,k = 270 kN
Partial resistance factor, bearing (Table A.NA.6); b,R1 = 1.00
Partial resistance factor, shaft (Table A.NA.6); s,R1 = 1.00
Design compressive resistance; Rc,d,C1 = (Rbk / b,R1 + Rsk / s,R1) / model = 349.1 kN
Fc,d,C1 / R c,d,C1 = 0.773
PASS - Design compressive resistance exceeds design load
Load combination 2: A2 + M1 + R4
Design compression action; Fc,d,C2 = G,unfav,A2 Gc,k,unfav - G,fav,A2 Gc,k,fav + Q,A2 Qc,k = 200 kN
Partial resistance factor, bearing (Table A.NA.6); b,R4 = 1.50
Partial resistance factor, shaft (Table A.NA.6); s,R4 = 1.30
Design compressive resistance; Rc,d,C2 = (Rbk / b,R4 + Rsk / s,R4) / model = 268.5 kN
Fc,d,C2 / R c,d,C2 = 0.745
PASS - Design compressive resistance exceeds design load
Axial tensile resistance
Load combination 1: A1 + M1 + R1
Design tension load; Ft,d,C1 = G,unfav,A1 Gt,k,unfav - G,fav,A1 Gt,k,fav + Q,A1 Qt,k = 270 kN
Partial resist. factor, shaft in tension (Table A.NA.6);s,t,R1 = 1
Design tensile resistance; Rt,d,C1 = Rsk / (s,t,R1 model) = 349.1 kN
Ft,d,C1 / R t,d,C1 = 0.773
PASS - Design tensile resistance exceeds design load
Load combination 2: A2 + M1 + R4
Design tension load; Ft,d,C2 = G,unfav,A2 Gt,k,unfav - G,fav,A2 Gt,k,fav + Q,A2 Qt,k = 200 kN
Partial resist. factor, shaft in tension (Table A.NA.6);s,t,R4 = 1.7
Design tensile resistance; Rt,d,C2 = Rsk / (s,t,R4 model) = 205.4 kN
Project Job no.

Fenog Nigeria Limited Calcs for Start page no./Revision

Warri 3
Calcs by Calcs date Checked by Checked date Approved by Approved date
R 08/08/2017

Ft,d,C2 / R t,d,C2 = 0.974


PASS - Design tensile resistance exceeds design load
;