The document describes the SC10E4NI M Series 4 Port ModbusTCP Gateway, which allows communication and data conversion between Modbus TCP, RTU, and ASCII protocols over Ethernet and serial ports. It has 4 serial ports that can be individually configured and 2 Ethernet ports that can operate in dual subnet or redundancy modes. The gateway supports communication between Modbus devices over Ethernet, serial, and virtual serial connections.

Uploaded by

srmohapatra5086
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
105 views2 pages

4 Port Modbustcp Gateway

The document describes the SC10E4NI M Series 4 Port ModbusTCP Gateway, which allows communication and data conversion between Modbus TCP, RTU, and ASCII protocols over Ethernet and serial ports. It has 4 serial ports that can be individually configured and 2 Ethernet ports that can operate in dual subnet or redundancy modes. The gateway supports communication between Modbus devices over Ethernet, serial, and virtual serial connections.

Uploaded by

srmohapatra5086
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

San Telequip (P) Ltd.

,
4 Crystal House, 235, Navi Peth
Off LBS Road, Pune 411 030, India
Phone : 91-20- 24320023, 24324423, 65001587 Connecting. Converting. Leading !
email : [email protected] .
4 Port ModbusTCP Gateway : Model SC10E4NI M
Modbus is an industry adopted communication protocol based on RTU, ASCII, and
TCP protocols for various applications; these three protocols are commonly used by
various equipments in the industry, such as DCS, PLC, HMI, power meters, various
sensor and measuring instruments.
The SC10E4 M Series support 16 simultaneous TCP master and 32 simultaneous
requests for each TCP master.

Each RS232/485/422 serial port can be individually configured for Modbus RTU or
Modbus ASCII, Master or Slave or even different baud rate

There are 2 Ethernet ports and they operates as :


Dual Subnet Mode : Two Ethernet ports have separate IP addresses and subnets
Redundancy Mode : The system will use only one port for data transfer. If the port is disconnected,
the whole system will change to another port automatically

SC10E4NI M Series Gateway supports


1. RS232/485/422 and Ethernet
2. Conversion of any Modbus protocols between Modbus TCP, Modbus RTU, and Modbus ASCII
3. ID routing when a Modbus ID conflict occurs
4. Function codes 1, 2, 3, 4, 5, 6, 15 & 16

Connection Architecture
1. Interfacing between Modbus/TCP over Ethernet network to Modbus RTU/ASCII Serial devices
2. Interfacing between Modbus RTU/ASCII serial host to Modbus RTU/ASCII serial devices. In this
case COM1 can be Modbus RTU Master & COM2,3,4 can have Modbus Slaves. The
communication is Serial to Serial only.
3. Interfacing between Modbus RTU/ASCII host connected through Virtual com port (VCOM) over
Ethernet to Modbus RTU/ASCII serial devices
San Telequip (P) Ltd.,
4 Crystal House, 235, Navi Peth
Off LBS Road, Pune 411 030, India
Phone : 91-20- 24320023, 24324423, 65001587 Connecting. Converting. Leading !
email : [email protected] .

Specifications
Ethernet : 2 nos. 2 MAC ids, 10/100M Fast-Ethernet, Auto-detection
Network Protocol : ICMP, TCP, IP, UDP Modbus TCP/ASCII/RTU, HTTP, ARP, SNMP, SMTP,
NTP, DHCP Client, DNS, Telnet
Modes : RTU Master/Slave, ASCII Master/Slave, TCP Master/Slave
Supports 16 simultaneous TCP Masters & 32 simultaneous request per TCP Master
Serial Interface : RS-232/422/485 software selectable. Each port can multidrop upto 32 slaves
Date Rate :1200 bps ~ 921 Kbps, Support user define baud rate
Data Bits :5, 6, 7, 8
Parity Check : None, Even, Odd, Space, Mark
Stop Bits :1, 2
Flow Control : None, XON/XOFF, RTS/CTS
Protection : 15KV ESD

Alerts : Emails, Traps, Syslog


Diagnostics : Data log, Syslog
Watch Dog Timer : 60-second software auto-reset. 1 second real-time clock built-in
Configuration : Web Browser, Windows-based Utility
MTBF :188251 hours / 21.5 years

Connector
Serial Port : 4-Port ; DB9 Male connector
Power
Power Input : DC 9 ~ 48V, 7-pin TB, Wattage : 5.85W max
Redundant : Yes
Mechanical
Dimension (W x H x D) mm : 53.4 x 145.7 x 119.9
Mounting : DIN-Rail
Weight : 900g
Environmental
Operation Temperature :-40C ~ 80C
Storage Temperature :-40C ~ 85C
Humidity : 5%~95% non-condensing

Ordering Information
SC10E4NIM : 4-Port Serial-to-Ethernet Modbus Gateway, DB9 (M)