Intial Tank Mass (KG) : Company Internal

The document contains data from 11 runs of an experiment measuring venturi pressure, turbine frequency, tank masses, and other variables. Key findings: 1) As the rotameter reading and venturi pressure increased from run to run, the mass flow rate through the venturi and turbine frequency also increased. 2) Calculations were performed to convert measurement units and determine values like flow rates, velocities, discharge coefficients, and mass flow rates. 3) The data was analyzed to study the relationship between the rotameter reading, venturi pressure, and other variables in the water flow system.

Uploaded by

esnow
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
37 views4 pages

Intial Tank Mass (KG) : Company Internal

The document contains data from 11 runs of an experiment measuring venturi pressure, turbine frequency, tank masses, and other variables. Key findings: 1) As the rotameter reading and venturi pressure increased from run to run, the mass flow rate through the venturi and turbine frequency also increased. 2) Calculations were performed to convert measurement units and determine values like flow rates, velocities, discharge coefficients, and mass flow rates. 3) The data was analyzed to study the relationship between the rotameter reading, venturi pressure, and other variables in the water flow system.

Uploaded by

esnow
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 4

Venturi Orifice

Pressure (hv peressure (Ho Turbine Intial Tank


Run Rotameter in WC) in WC) frequncey (hz) Mass (kg)
1 2 12 22 8 27
2 2.25 15 28 9 27
3 2.5 20 42 11 28
4 2.75 25 48 11 28
5 3 28 57 13 29
6 3.25 30 64 13 28
7 3.5 35 75 14 29
8 3.75 40 92 16 30
9 4 45 105 17 31
10 4.25 50 115 17 30
11 4.5 56 130 18 32

conversions for water pressure h0 in feet


1 1.8333333333 1.8333333333 rho of water
1.25 2.3333333333 2.3333333333
1.6666666667 3.5 3.5
2.0833333333 4 4
2.3333333333 4.75 4.75
2.5 5.3333333333 5.3333333333
2.9166666667 6.25 6.25
3.3333333333 7.6666666667 7.6666666667
3.75 8.75 8.75
4.1666666667 9.5833333333 9.5833333333
4.6666666667 10.8333333333 10.8333333333

Company Internal
final Tank
Mass (kg) Time (s) mass flow rate velocity flow rate (SI)
33 54.23 0.1106398672 0.0001107506
32 40.36 0.1238850347 0.000124009
33 32.75 0.1526717557 0.0001528246
33.5 32.8 0.1676829268 0.0001678508
34.5 31.96 0.1720901126 0.0001722624
33.25 26.6 0.1973684211 0.000197566
36 32.23 0.2171889544 0.0002174064
35.5 24.4 0.2254098361 0.0002256355
37.5 26.91 0.2415458937 0.0002417877
37.5 27.57 0.2720348205 0.0002723071
40 29.59 0.2703616087 0.0002706322

1.7579463151

62.4 lb/ft^3
1.94 slg/ft^3 beta 0.5271186441
area 0.0005275312
0.0259166667

Company Internal
Rotometer Reading Flow Rate Q (GPM) Qo Orifice Flow Rate Qv venturi Cd orifice
2 1.7536831072 0.2643101428 0.0059646271 0.1507171631
2.25 1.963623945 0.2955077233 0.0067290069 0.150490996
2.5 2.419904196 0.3412229271 0.0082413167 0.1410067918
2.75 2.6578368494 0.3814988303 0.0088103381 0.1435373395
3 2.7276923861 0.4037404122 0.0096008434 0.1480153753
3.25 3.1283629902 0.41791103 0.0101733021 0.1335877682
3.5 3.4425258264 0.4513955034 0.0110129226 0.1311233455
3.75 3.5728298631 0.4825620914 0.0121973608 0.1350643915
4 3.8285923874 0.5118343907 0.0130306658 0.1336873553
4.25 4.3118532328 0.5395208198 0.0136370639 0.1251250427
4.5 4.2853322024 0.5709751666 0.0144991864 0.1332394175

15834.5221112696

Company Internal
Cd enturi Cd enturi Cd enturi

Company Internal