GEI-M1026 Installation Vertical Non-Reverse-Bolted Coupling PDF
GEI-M1026 Installation Vertical Non-Reverse-Bolted Coupling PDF
GEI-M1026 Installation Vertical Non-Reverse-Bolted Coupling PDF
GE Motors
Bolted Coupling
Installation Instructions
High Thrust
Hollow Shaft
Frames 213-449 NEMA Type P-Base
Weather Protected Type - I
Ball Type NRC (Non Reverse Coupling) & Bolted Coupling
GEI-M1026
High voltage and rotating parts can Avoid extended exposure in close proximity
cause serious or fatal injuries. with high noise levels.
Installation, operation and mainte-
nance of electric machinery should be Use proper care and procedures in handling,
performed by qualified personnel. lifting, installing, operating and maintaining
Familiarization with NEMA Publication MG-2, the equipment.
Safety Standard for Construction and Guide
for Selection, Installation and Use of Electric The motor should be lifted by the lugs
Motors and Generators, the National Electrical provided. Do not lift anything but the motor
Code and sound local practices is with the motor lifting means.
recommended.
For equipment covered by this instruction Safe maintenance practices by qualified
book, it is important to observe precautions to personnel are imperative. Before starting
protect personnel from possible injury. Among maintenance procedures, be positive that:
the many considerations, personnel should be
instructed to: Equipment connected to the shaft will not
cause mechanical rotation.
Avoid contact with energized circuits or
rotating parts. Main machine windings and all accessory
devices associated with the work area are
Avoid bypassing or rendering inoperative disconnected from electrical power sources.
any safeguards or protection devices.
Avoid use of automatic-reset thermal If a high potential insulation test is required,
protection where unexpected starting of procedures and precautions outlined in NEMA
equipment might be hazardous to Standard MG-1 and MG-2 should be followed.
personnel.
Failure to properly ground the frame of this
Avoid contact with capacitors until safe machine can cause serious injury to personnel
discharge procedures have been followed. or death. Grounding should be in accordance
with the National Electrical Code and consistent
Be sure the shaft key is fully captive before
with sound local practice.
the motor is energized.
These instructions do not purport to cover all of the details or variations in equipment nor to provide for every possible
contingency to be met in connection with installation, operation, or maintenance. Should further information be desired or
should particular problems arise which are not covered sufficiently for the purchaser's purposes, the matter should be
referred to the General Electric Company.
2
GEI-M1026
It shall be the installers responsibility in all cases to ascertain these torque values are used
and maintained. This shall include those instances when the coupling comes mounted in the
motor. Failure to comply may cause the coupling bolts to break, with resultant, extensive
damage to the equipment.
Upper Half-Coupling
Cover Plate Bolts
Cover Plate
3
GEI-M1026
Upper Half-Coupling
Cover Plate Bolts
Cover Plate
Cover Plate Lock
Washers
Lower Half-Coupling
(Located on motor). Ratchet Plate
4
GEI-M1026
It shall be the installers responsibility in all cases to ascertain these torque values are used
and maintained. This shall include those instances when the coupling comes mounted in the
motor. Failure to comply may cause the coupling bolts to break, with resultant, extensive
damage to the equipment.
5
GEI-M1026
6
GEI-M1026
g
To:
GE Motors
Attn: Industrial Engineering
Technical Publications Editor
Reader Comments 1030 Swinney Ave, Bldg 26-2
Fort Wayne IN 46802-4332
General Electric Company Fax: 260-439-3881
(GE Internal DC: 8*380-3881)
Your Job Function / How You Use This Publication Publication No. E-Mail
General Rating
Excellent Good Fair Poor Additional Comments
Contents
Organization
Technical Accuracy
Clarity
Completeness
Drawings / Figures
Tables
Referencing
Readability
Specific Suggestions (Corrections, information that could be expanded on, and such.)
Other Comments (What you like, what could be added, how to improve, and such.)
Overall Grade (Compared to publications from other manufacturers of similar products, how do you rate this publication?)
7
GEI-M1026
Place
Stamp
Here
GE MOTORS
INDUSTRIAL ENGINEERING TECHNICAL
PUBLICATIONS EDITOR
1030 SWINNEY AVE, BLDG 26-2
FORT WAYNE IN 46802-4332 USA
8
GEI-M1026