Pump sizes range from DN 32 to 150 with capacities up to 850 m3/h. Heads can reach up to 630 m.

File Name: KSB_Pump_Multitec_spec_D1003

Product Introduction
1777.1/4-10 G3 Multitec
High-Pressure Pumps in Ring-Section Design

Applications Bearings/Lubrication
General water supply Distillate Drive side: rolling element bearings
Pressure boosting Industry Suction side: plain or rolling element bearings, depending on
Municipal water supply Filter systems installation type
Drinking water supply Solvents Lubrication: Rolling element bearings grease lubricated, oil
Irrigation Fire-fighting systems lubrication possible
Heating Washing systems Plain bearings are product lubricated.
Boiler feed water Reverse osmosis
Warm water Lubricants Shaft seal
Hot water Fuels Standardized mechanical seal, uncooled or cooled, single-act-
Circulation Process ing or double-acting.
Condensate Power plants Cartridge seals possible.
Uncooled gland packing with or without barrier liquid.
Operating data
Pump sizes DN 32 up to 150
Capacities Q up to 850 m3/h, 236 l/s Designation
Heads H up to 630 m
Operating temperature t --10 _C up to +200 _C Multitec A 32 / 8E - 2.1 12 . 65 (SP)
Operating pressures p2 25 up to 63 bar 1) Pump series
Standard flanges DIN Installation type
Suction nozzle PN 16 (JL1040) and DN discharge nozzle
PN 25 (GP240GH+N, 1.4408) Number of stages/Impeller combination
Discharge nozzle PN 40 (JL1040) and Hydraulics
PN 63 (GP240GH+N, 1.4408) Material variant
Standard flanges ASME Shaft seal code
Suction nozzle Class 125 (JL1040) and Code for special variants (optional)
Class 300 (GP240GH+N, 1.4408) Materials
Discharge nozzle Class 250 (JL1040) and
Class 600 (GP240GH+N, 1.4408) Cast iron JL1040,
1) The total of inlet pressure and head at zero flow must not exceed the specified value Hydraulic elements: bronze CC480K-GS (water works vari-
ant), cast steel GP240GH+N, alloyed cast steel 1.4408
Design
Horizontal or vertical multistage centrifugal pump in ring section
Drive
design, as long-coupled (baseplate mounted) or close-coupled Electric motor 50 and 60 Hz;
unit. Diesel engine or turbine up to nmax. 4000 1/min possible
Axial or radial suction nozzle. Radial suction and discharge
nozzle can be turned in multiples of 90. Certification
Flanges to EN, DIN and ANSI (bolt holes, flange face)
Closed radial impellers, from pump size 50 upwards first stage Certification of quality management ISO 9001
with suction impeller to improve the NPSH value.

DIN EN ISO 9001


General Member of
Multitec
Kennfelder / Selection charts / Rseau / Conjunto de curvas / Campi caratteristici / Grafieken / Arbetsomrde
n = 2900 1/min (1.4408)
10 US.gpm 20 30 40 50 100 200 300 400 500 1000 2000 3000 4000

10 20 30 40 50 IM.gpm 100 200 300 400 500 1000 2000 3000


700
2000

500
125 9.1
125 10.1
400 150 11.1 150 12.1

65 6.1

300 100 8.1 1000


50 3.1
50 4.1 65 5.1 100 7.1 150 11.2
150 12.2
125 9.2

200
125 10.2

500

32 2.1
400

100
300

H
[m]
200

50
ft
40

30 100

25
3
2 3 4 5 Q[m /h] 10 20 30 40 50 100 200 300 400 500 1000

1 l/s 2 3 4 5 10 20 30 40 50 100 200


KE1777.ES.S.452/1
n = 3500 1/min (1.4408)
20 30 40 50 US.gpm 100 200 300 400 500 1000 2000 3000 4000

10 IM.gpm 20 30 40 50 100 200 300 400 500 1000 2000 3000 4000
700
2000

500

400

100 8.1
65 6.1
125 9.1 125 10.1
300 1000
150 11.2
65 5.1 100 7.1
50 4.1 150 12.2
50 3.1
125 9.2
125 10.2

200
32 2.1

500

400

100
300

ft
H
[m]
200

50

40
35
3
2.5 3 4 5 Q[m /h] 10 20 30 40 50 100 200 300 400 500 1000 1400

1 l/s 2 3 4 5 10 20 30 40 50 100 200 300


KE1777.ES.S.462/1

2
Multitec

Selection of material/shaft seal depending on the pumped liquid


Pumped liquid Material Shaft seal Notes
p2 max 140 C 200 C 100 C 140 C 200 C
in bar
Sewage, raw water 1) 40 10 63, 65 Non-aggressive pumped liquid, no
slightly contaminated water 63 20 abrasive components
Drinking water 1) 40 11,12 65,615),63 Water works variant
63 22
Fire-fighting water 1) 40 11,12 65,615),62
Cooling water 40 10 65,615),62 Non-aggressive pumped liquid, no
63 20 abrasive components
Boiler feed water 2) 40 10 20 65,615),62 66, 62 64 O2 content 0.02 mg/kg
p g mode AF,, pH
Operating p > 9 (objective
( j 63 20 20
9.3) at 25 C 40 22 22 65,615),62 62 64
63 22 22
Boiler feed water 2) 40 10 20 65,615),62 66, 62 64 O2 content 0.02 mg/kg
p g mode AFT,, pH
Operating p > 9 (objective
( j 63 20 20
9.3) at 25C 40 22 22 65,615),62 66, 62 64
63 22 22
Boiler feed water 2) 40 30 30 615),62 62 64 O2 content 0.05 mg/kg
Operating mode NF. pH 6.5 at 25 C 63 30 30
Boiler feed water 2) 40 22 22 65,615),62 66, 62 64 O2 content 0.15 up to 0.3 mg/kg
Operating mode KF. pH 8 - 8.5 at 25 C 63 22 22
Condensate 2) 40 10 20 615),62 62 64 O2 content 0.02 mg/kg
Operating mode AF, pH > 9 (objective 63 20 20 temperature 190 C 4)
9.3) at 25 C
Condensate 2) 40 30 30 615),62 62 64
Operating mode NF, pH 6.5 at 25 C 63 30 30
Condensate 2) 40 22 65,615),62 66, 62 64 O2 content 0.15 mg/kg
Operating mode KF, pH 8 at 25 C 63 22 temperature 110 C 4)
Raw water for reverse osmosis plants 40 30 30 615),62 62 64 For higher chloride content (sea
63 30 30 water) contact KSB
In case of prolonged shutdown,
drain and flush the pump
Oil-water mixture, 40 10 65, 63
oil emulsion 63 20
Glycol-water mixtures 40 10 65,615),62 66, 62
63 20
Degreasing baths, washing solution for 40 10 65, 63 3) e.g. P -lye
3
metal cleansing, 63 20 for acid baths please contact KSB
alkaline cleaning agents
1) General assessment criteria when a water analysis is available: pH value 6.5; chloride AF = Water is fully demineralised, pH value set to > 9 (e.g. using ammonia).
content (Cl) 150 mg/kg, chlorine (Cl2) 0.6 mg/kg. For bronze components, the
following additional limits apply: ammonia (NH3) 5 mg/kg, free of hydrogen sulphide AFT = Water is partly demineralised, pH value set to 9, mainly with solid alkalising
(H2S); the limitation of the Cl content does not have to be applied in this case. If these agents, possibly additional dosing of ammonia.
limits are not complied with, please contact KSB.
NF = Water is fully demineralised, pH value 7-8, O2 content increased
2) The values must be assured upstream of the pump inlet under all operating conditions. to 0.05-0.25 mg/kg by adding oxygen or hydrogen peroxide.
Water treatment shall comply with the VdTV regulations for feed and boiler water grades
for steam plants up to 64 bar. KF = Water is fully demineralised, alkalised to pH values from 8 to 9, O2 content increased
Air ingress into the system must be avoided by all means. We therefore recommend to to 0.03-0.15 mg/kg by adding oxygen or hydrogen peroxide.
use a mechanical seal as a shaft seal.
Notes for the suction pipe layout:
Max. flow velocity approx. 1.5 m/s, low pressure loss arrangement (few pipe fittings/
valves, low drag valves, e.g. gate valves instead of globe valves, pipe arrangement short
and vertical, horizontal sections should be located at the deepest position).
Using impellers made of G-CuSn10 is only possible when no additives containing ammo-
nia (e.g. Hydrazin) are used for water treatment.
3) max. 80 C; pH value > 9.5
4) Values drawn from experience
5) See application limits on page 6

3
Multitec
Operating ranges depending on installation type
640

Installation type A, B, C, D
400

H
m

Installation type A, B, C, D, V Installation type A, B, C, D


250

Installation type A, B, C, D, E, Ex, Installation type A, B, C, D, V Installation type A, B, C, D


F, Fx, V, Vx
DN 65 DN 125 DN 150

Heads given for n = 2900 1/min and n = 3500 1/min

4
Multitec
Technical Description
Installation type Technical description

Installation type A 5) Horizontal design, baseplate mounted, Drive Electric motor, Diesel engine, turbine
rolling element bearings on drive side,
side
plain bearings on suction side, Axial thrust By balance drum 1)
one shaft seal only,
y, balance
axial
i l suction
ti nozzlel
(block flange up to pump size 50), Qmax 2) 840 m3/h
drive on discharge side Hmax 630 m
For the entire Q/H range p2 max 63 bar
Installation type B 5)
Same as installation type A, but with tmax -10 up to +200 C
radial suction nozzle
Shaft seal Uncooled packing;
cooled or uncooled mechanical seal
single or double-acting
Cartridge seals
Material Grey cast iron JL1040, bronze
CC480K-GS, cast steel 1.0619+N, 1.4408

Installation type C 5) Horizontal design, baseplate mounted, Drive Electric motor, Diesel engine, turbine
rolling element bearings on drive and
suction side, Axial thrust By balance drum 1)
shaft seals at both ends,, balance
d i on discharge
drive di h side
id
Qmax 2) 840 m3/h
For the entire Q/H range Hmax 630 m
p2 max 63 bar
Installation type D 6)
Same as installation type C, but drive tmax -10 up to +200 C
on suction side
Shaft seal Uncooled packing;
cooled or uncooled mechanical seal
single or double-acting
Cartridge seals
Material Grey cast iron JL1040, bronze
CC480K-GS, cast steel 1.0619+N, 1.4408

Installation type E, Ex 5) Horizontal close coupled pump, Ex, Fx E, F


common bearing for pump and motor,
motor
rigid coupling, Drive Electric motor with Standardized
radial suction nozzle special rolling ele- motor
ment bearing
up to DN 65 Axial thrust Held by motor By balance drum
balance bearing
Qmax 2) 100 m3/h
Hmax 250 m
Installation type F, Fx 5) Same as installation type E, Ex, but p2 max 25 bar 40 bar
with axial suction nozzle
tmax -10 up to +140 C
up to
t DN 65
Shaft seal Uncooled packing;
uncooled mechanical seal
single-acting
Material Grey cast iron JL1040, bronze
CC480K-GS, other materials on request
5) Vertical close coupled pump Vx V
Installation type V, Vx
Q/H range2): 2-pole: Drive Electric motor with Standardized
up to QOpt=180 m3/h, special rolling ele- motor
250 m ment bearing
up to QOpt= 85 m3/h,
/ Fixed bear- DN 100
400 m ing in lantern DN 125 3)
4-pole: Axial thrust Held by motor By balance drum
up to QOpt= 175m3/h, balance bearing
250 m
Qmax 2) 4) 100 m3/h 170 m3/h
Hmax 4) 250 m 400 m 250 m
p2 max 4) 25 bar 40 bar
tmax -10 up to +140 C
Shaft seal Uncooled packing;
uncooled mechanical seal
single-acting
Material Grey cast iron JL1040, bronze
CC480K-GS, other materials on request
1) For small number of stages without balance drum: axial thrust fully 3) DN 150 on request
held by the axial bearings 4) Other operating data on request
2) N.B.: The values given for Q apply to 50 Hz; for 60 Hz values please 5) Clockwise drive rotation when viewed from the motor end
refer to the specific performance curves. 6) Anti-clockwise drive rotation when viewed from the motor end
5
Multitec
Pressure and temperature limits
Material JL1040 (GJL-250) Material GP240GH+N (1.0619+N)
ASME Class 600

60 60 EN 1092-1, PN 63
(DIN 2546, PN 63)

EN 1092-2, PN 40
(DIN 2535, PN 40)
40 40

p ASME Class p EN 1092-1, PN 25


bar 250 bar (DIN 2544, PN 25) ASME Class 300
EN 1092-2, PN 16
20 (DIN 2533, PN 16) 20

ASME Class 125

0 0
--10 0 50 t C 100 140 150 200 --10 0 50 t C 100 150 200
Material 1.4408

60
ASME Class 600

EN 1092-1, PN 63
(DIN 2546, PN 63)
40

p
bar ASME Class 300

20
EN 1092-1, PN 25
(DIN 2544, PN 25)

0
--10 0 50 t C 100 150 200

Shaft seal code 2)


Mechanical seal
Uncooled mechanical seal Cooled mechanical seal
Temp. limits up to 100 C up to 140 C up to 200 C 3)
Non-balanced bellows-type 61 1) 4)
seal RMG 13
(U3BEGG) pump sizes 32 and 50 only
-- --
Balanced seal
H12N 62 4) 62 4) --
(AQ1EGG)
Balanced seal
Solids-laden media 63 5) -- --
H17GN (Q12Q1VGG) 6)
Balanced seal
H75N -- -- 64 4)
(AQ1EGG)
Gland packing
Pmax up to 100 C (RAMIE / PTFE) up to 140 C (ARAMID / SILIKON)
without balance drum 25 bar
with balance drum 63 bar
65 5) 66 4)

Design N/b N/c


Plant conditions with suction head operation PS abs. < 1 bar (vacuum vessel)
PS abs. 1 bar with clean external sealing liquid
barrier pressure > pressure to be sealed
Technical features without lantern ring 1 lantern ring on suction side
1 lantern ring on discharge side
2 tapped holes for auxiliary pipework
1) pmax without balance drum = 18 bar; pmax with balance drum = 63 bar
2) Other seal variants on request
3) Air-cooled up to DN 100 (installation types A, B, C and D, electric motor IP 55, 2-pole, only); otherwise water-cooled.
4) static seals in EPDM
5) static seals in FPM
6) H75N (Q1Q1VGG) for pump size 150

6
Multitec

Materials table
Part no. Description Material code
10 3) 11 3) 12 3) 20
106 Suction casing JL1040 JL1040 JL1040 GP240GH+N
107 Discharge casing JL1040 JL1040 JL1040 GP240GH+N
108 Stage casing JL1040 JL1040 S355J2G3 1)/JL1040 2) S355J2G3 1)/
GP240GH+N 2)
171 Diffuser JL1040 2)6) JL1040 2)6) CC480K-GS JL1040
210 Shaft C45+N 4) C45+N 4) C45+N 4) C45+N 4)
230 Impeller JL1040 CC480K-GS CC480K-GS JL1040
231 Suction impeller JL1040 CC480K-GS CC480K-GS JL1040
350 Bearing housing JL1040 JL1040 JL1040 JL1040
381/529 Plain bearing assy. SiC/SiC SiC/SiC SiC/SiC SiC/SiC
441 Stuffing box housing JL1040 JL1040 JL1040 GP240GH+N
502 7) Casing wear ring JL1040 2) CC493K-GS 2) CC493K-GS 2) JL1040
523 Shaft sleeve 1.4057+QT800 1.4057+QT800 1.4057+QT800 1.4057+QT800
524 Shaft protecting sleeve 1.4122 1.4122 1.4122 1.4122
550.1 8) Disc 1.4571 1.4571 1.4571 1.4571
59-4 Balance drum JL1040 1.4021 1.4021 JL1040
540 Bush JL1040 JL1040 JL1040 JL1040
905 Tie bolt C45K (or 42 CrMo4) C45K (or 42 CrMo4) C45K (or 42 CrMo4) 1.6772 (Monix 3K)

Part no. Description Material code


21 22 23 30
106 Suction casing GP240GH+N GP240GH+N GP240GH+N 1.4408
107 Discharge casing GP240GH+N GP240GH+N 1.4408 1.4408
108 Stage casing S355J2G3 1)/ S355J2G3 1)/ S355J2G3 1)/ 1.4404 1) 1.4408 2)
GP240GH+N 2) GP240GH+N 2) GP240GH+N 2)
171 Diffuser JL1040 1.4408 1.4408 1.4408
210 Shaft C45+N 4) 1.4021+QT 1.4021+QT 1.4462
230 Impeller JL1040 1.4408 1.4408 1.4408
231 Suction impeller 1.4408 1.4408 1.4408 1.4408
350 Bearing housing JL1040 JL1040 JL1040 JL1040
381/529 Plain bearing assy. SiC/SiC SiC/SiC SiC/SiC SiC/SiC
441 Stuffing box housing GP240GH+N GP240GH+N 1.4408 1.4408 5)
502 7) Casing wear ring JL1040 1.4138 1.4138 1.4571
523 Shaft sleeve 1.4057+QT800 1.4571 1.4571 1.4571
524 Shaft protecting sleeve 1.4122 1.4122 1.4122 5)
550.1 8) Disc 1.4571 1.4571 1.4571 1.4571
59-4 Balance drum JL1040 1.4021 1.4021 1.4301
540 Bush JL1040 1.4021 1.4021 1.4301
905 Tie bolt 1.6772 (Monix 3K) 1.6772 (Monix 3K) 1.6772 (Monix 3K) 1.6772 (Monix 3K)
1) For pump sizes DN 32 up to 100 6) Integrated in stage casing of pumps sizes 32 to 100.
2) For pump sizes DN 125 and 150 7) Pump sizes 125 and 150 only, and casing wear ring in suction casing for pump sizes 32 to 100 of material
3) Up to t 140 _C variants 20 to 30
4) Available in material 1.4021 8) For pump sizes 32 to 100 only, also used as casing wear ring
5) Only provided for seal codes 61, 62, 63, 64 (no packing)

Material Equivalents
Description Short designation and material No. Standard to NF A to ASTM
Cast iron JL1040 / GJL-250 EN 1561 -- A48:40B
Cast bronze CC480K-GS EN 1982 -- B505C90250
Cast bronze CuSn7Zn4PB7-C-GS/CC493K-GS EN 1982 -- B585C93200 (similar)
Steel C45+N / 1.0503+N EN 10083-2 -- A29Gr.1045
Steel C45K / 1.0503 K DIN 1652 AF65C45 A663
Steel S355J2G3 / 1.0570 EN 10025 E36-4 A678C
Cast steel GP240GH+N / 1.0619+N EN 10213-2 -- A216WCB
Chrome steel 1.4021+QT / X20Cr13+QT EN 10088 -- A276:420
Chrome nickel steel 1.4122 / X35CrMo17 EN 10088 -- A276S42010 (similar)
Chrome nickel steel 1.4057+QT800 / EN 10088-3 -- A276:431
X17CrNi16-2--QT800
Chrome molybdenum cast steel 1.4138 / GX120CrMo29-2 SEW 410 Z1200D29-02-M --
Chrome nickel steel 1.4301 / X5CrNi18-10 EN 10088 -- A276:304
Chrome nickel molybdenum steel 1.4404 / X2CrNiMo 17-12-2 EN 10088 -- A276:316L
Chrome nickel molybdenum cast
1.4408 / GX5CrNiMo19-11-2 EN 10213 -- A743CF8M
steel
Chrome nickel molybdenum steel 1.4462 / X2CrNiMoN22-5-3 EN 10088 -- A473 S32950
Chrome nickel molybdenum steel 1.4571 / X6CrNiMoTi17-12-2 EN 10088 -- A276:316
Silicon carbide SiC -- Carbure de silicium SiC
without free silicon sans silicium libre without free silicon
Bar steel 1.6772 / 20NiCrMo14-5 I VdTV 337 16NC11n. A36-612 A540 Gr. B24
Steel 42CrMo4 / 1.7225 EN 10083-1 -- A322GR.4140 (similar)

7
Multitec
Benefits at a glance
1st stage with special suction Newly developed hydraulics Wear rings made of 1.4571 Axial thrust balancing with
impeller - High efficiencies Pump size 32 to 100: standard balance drum
- low NPSH required - Low operating costs Pump size 125 to 150: - Low bearing loads under
- reliable for suction lift depending on material variant variable operating conditions
operation thanks to improved - Highly resistant - Low pressure in the shaft
suction behaviour - Easily replaceable with low costs seal area
- Long life of rolling element
bearings and shaft seal

between bearings design

Subject to technical modifications.


Adaptation of the material Plain bearings made of silicon Shaft sealed by Shaft protecting sleeve made of
from many possible options carbide - Uncooled gland packing up to 140 C alloyed steel
(JL 1040, Bronze, - Longer service life - Standardized mechanical seal, - Efficient protection of the shaft
GP240GH+N, 1.4408) - Higher reliability balanced or non-balanced from wear
- Low maintenance costs Uncooled up to 140 C, - Quick and simple replacement
- One shaft seal only cooled up to 200 C of the shaft seal
- Dimensioned for start-stop - Single or double-acting, cartridge
operation and all speeds seals

d/4

1777:7

Mechanical seal, Double acting


single-acting mechanical seal, e.g.
tandem arrangement
d/4

1777:5
01.03.2002

Axial inlet
pump size 65

Installation type V;
Separate rolling element bearing
in the motor lantern from pump
size 100 upwards
Installation type E

KSB S.A.
Alle de Sagan - B. P. 189 . 36004 Chteauroux Cedex
Tl.: (02) 54 08 84 00 Fax: (02) 54 08 84 91 http://www.ksb.com