Astm C136 - Sieve Analysis of Fine & Coarse Aggregates: Semi-Log Gradation Chart
Astm C136 - Sieve Analysis of Fine & Coarse Aggregates: Semi-Log Gradation Chart
Astm C136 - Sieve Analysis of Fine & Coarse Aggregates: Semi-Log Gradation Chart
SIEVE ANALYSIS
Mass of Mass of Mass Percent Cumulative
Sieve Diameter Percent
Empty Retained Retained
Sieve+Retain Percent
Passing[%]
Number [mm] ed [g] Retained [%]
Sieve [g] [g] [%]
4 4.750 515.000 1836.000 1321.000 62.3 62.3 37.7
8 2.360 479.000 514.000 35.000 1.6 63.9 36.1
16 1.190 422.000 500.000 78.000 3.7 67.6 32.4
30 0.595 399.000 538.000 139.000 6.6 74.1 25.9
50 0.297 371.000 619.000 248.000 11.7 85.8 14.2
100 0.106 340.000 582.000 242.000 11.4 97.2 2.8
200 0.075 340.000 397.000 57.000 2.7 99.9 0.1
Pan --- 367.000 369.000 2.000 0 100.0 0.0
Total 2122.000 100.000
2.360; 36.1; #8
30.0
20.0
10.0
% = *100 = 1321.000
* 100 = 62.253%
2122.000
1
=
100
For Fine Aggregates: #4, #8, #16, #30, #50 and #100
4295
1. = = 268.4375
4466 - 4450
Where
A = Mass of oven-dry sample in air, g = 4295 g
B = Mass of saturated surface-dry sample in air, g = 4466 g
C = Mass of saturated sample in water, g = 4450 g
4466
2. = = = 279.1250
4466 - 4450
4295
3. = = = -27.7097
4295 - 4450
4466 - 4295
4. % = *100 = = 3.9814%
4295
ASTM C128 - SPECIFIC GRAVITY AND ABSORPTION OF FINE AGGREGATE
500
1. = = = 2.3585
+ 668 + 510 - 966
Where
A = Mass of oven-dry sample in air, g = 500 g
B = Mass of pycnometer filled with water, g = 668 g
C = Mass of pycnometer with specimen and = 966 g
water to the calibration mark, g
S = Mass of the saturated surface dry specimen, g = 510 g
510
2. ( )= = = 2.4057
+ 668 + 510 - 966
500
3. = = = 2.4752
+ 668 + 500 - 966
510 - 500
4. % = *100 = = 2.0000%
500
ASTM C29 - BULK DENSITY (UNIT WEIGHT) AND VOIDS IN AGGREGATE
EXAMPLE CALCULATION FOR BULK UNIT WEIGHT AND PERCENT VOIDS OF AGGREGATES
3.7810 - 0.7320 kg
1. = = = 1709.1802
0.0018 m^3
Where:
G = = 3.7810 kg
Weight of the aggregate plus the measure, kg
2352.0174 - 1709.1802
2. % = = = 27.3313%
2352.0174
3. Method of Compaction: Rodding - because sample aggregate is lesser than the nominal maximum size of
37.5 mm (1 1/2 in)