Error Codes
Error Codes
In case of washing-machine fault in carrying out the self-test function, the machine reproposes the
fault previously signaled and the same fault is shown on the display of the new hardware key.
3. The control panel LEDs light up, to signal the fault, according to the table (fig. 01).
The example shown in fig. 02 (Example Fault F03) below indicates which LEDs are flashing if the
machine has Fault F03
List of faults, malfunctions and Warnings:
- Check for water leaks that may affect connector J9 causing the relevant contacts to short
- Check the motor terminal block (possible problems due to chemical effects of work residuals on the
contacts which may cause short-circuiting)
- Replace Card
- Check the tachometric winding verifying an ohmic resistance reading of 115 - 170 ohm between
pins 1 and 2 on wiring connector J9. In case of short circuit/open circuit check the wiring between
pins 1 and 2 of J9 relevant to the tachometrics. With three-phase motor, make sure there is ohmic
continuity between J9 pins 6 and 7.
- Replace motor
- Replace card
F03: NTC Open or in Short Circuit or washing heater relay stuck (signaled in presence of full load)
- Check NTC verifying that the ohmic resistance value at room temperature 20C is approx. 20Kohm
on J8 wiring connector pin 11 and 12.
- Replace NTC
- Replace Card
If the pressure switch contact is stuck on empty the washing-machine loads water until reaching the
overflow. The drain pump is automatically started by the contact on the overflow pressure switch.
- Check efficiency of J3 connector contacts on card
- Check pressure switch status by checking ohmic continuity on wiring connector J3 pins 2 and 4 (it
must only be present with tub empty), pins 2 and 3 (it must only be present with water in the drum)
and pins 2 and 1 (it must only be present with water in the tub above normal level, more than
halfway up door glass).
- Replace card.
- Check efficiency of J9 connector on card, verifying a voltage of 220V between pins 8 and 9
- Change Pump
- Replace Card
F07: No Wash Heating Element Absorption (the fault is only signaled with the pressure switch on
empty)
- Check continuity of the wash heating element on J3 connector pins 5 and 6. The 1800W 230V
heating element has a resistance of 25 ohm.
- Check connection of pressure switch J3 connector pins 2 and 3: there must not be ohmic continuity
(shared with full load).
Check connection of pressure switch J3 connector pins 2 and 4: there must be ohmic continuity
- Replace Card
F08: Wash Heater Relay Stuck (signaled in presence of empty) or pressure switch stuck on Full
(simultaneously empty and full)
- Check pressure switch status by checking ohmic continuity on wiring connector J3 pins 2 and 4 (it
must only be present with tub empty), pins 2 and 3 (it must only be present with water in the drum)
and
pins 2 and 1 (it must only be present with water in the tub above normal level, more than halfway up
door glass).
- Replace Card
- In case of production card with Eeprom soldered: replace the card and Eeprom
- In case of replacement of Eeprom and card, check correct housing of Eeprom on card socket
- Check pressure switch status by checking ohmic continuity on wiring connector J3 pins 2 and 4 (it
must only be present with tub empty), pins 2 and 3 (it must only be present with water in the drum)
and
pins 2 and 1 (it must only be present with water in the tub above normal level, more than halfway up
door glass).
- Replace Card
- Replace Pump
- Replace Card
F13: Drying NTC sensor open / Drying system NTC wiring disconnected
Check NTC on J10 connector pins 7 and 8 verifying that the ohmic value of the sensor at room
temperature 20C is approx. 20Kohm
Replace NTC
Replace card
Check continuity of drying heater on J2 wiring connector pins 1 and 2, verifying that the ohmic value
of the 1300W 230V heating element is approx. 40Kohm
Replace card
F15: Drying heater always on (drying relay contact stuck or drying Triac short circuit)
Replace card
- Check presence of 230V mains power on J4 wiring connector inserted on card between pins 3 and
4, (not present with machine on standby) and presence of power from 230V door lock between pins
3 and 5
- Check ohmic continuity of the door microswitch on J4 connector inserted on card between pins 1
and 2 (with door closed/on open/off)
- Replace card
F17: (b) Door lock unfed/open (conventional door lock, not Easy Door)
- Check presence of 230V mains power on J4 wiring connector inserted on card between pins 2 and
3, (not present with machine on standby) and presence of power from 230V door lock between pins
3 and 1
- Replace card