100% found this document useful (2 votes)
814 views10 pages

RC.1 Example 4.1&6.1

The document provides details to calculate the reinforcement required for a propped cantilever beam subjected to uniform dead and live loads. It determines the critical moments of 177 kNm for negative bending and 99.56 kNm for positive bending. It then calculates the required reinforcement areas for the negative and positive moments using the section properties and material strengths provided. The reinforcement is to be curtailed to 30% of the length for both positive and negative reinforcement as shown in a sketch.

Uploaded by

ሽታ ዓለሜ
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
100% found this document useful (2 votes)
814 views10 pages

RC.1 Example 4.1&6.1

The document provides details to calculate the reinforcement required for a propped cantilever beam subjected to uniform dead and live loads. It determines the critical moments of 177 kNm for negative bending and 99.56 kNm for positive bending. It then calculates the required reinforcement areas for the negative and positive moments using the section properties and material strengths provided. The reinforcement is to be curtailed to 30% of the length for both positive and negative reinforcement as shown in a sketch.

Uploaded by

ሽታ ዓለሜ
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 10

Example 4.

1
The simply supported parallel T-beams sustain floor system which span 7m and
subjected to a total design BM of 500kNm. The beams are spaced at 2000mm on
centerline. The other beam dimensions are hf = 800mm, bw = 400mm, D = 400mm.
Materials, fck = 20MPa; steel, fyk = 300MPa and class I work. Determine the tensile steel
area required at mid-span of and interior beam.
Solution

Constants:
A A fcd = 11.3Mpa
7m fyd = 260.87Mpa
M = 28.78
C1 = 2.5
C2 = 0.32fcd = 3.616MPa
2m 2m 2m

80mm=hf
D=400mm

Bw=400mm

Section A-A

Check depth for deflection


f ykLe
Beam, d (0.4 + 0.6* ) Le = 7000
400 a

a = 20
300 7000
d (0.4 + 0.6 * )* = 297.5mm
400 20
D 297.5 + 75 = 372.5mm<400mmsafe.
For +ve BM flauge is on compression side

1
l 7000
bw 5 400 1800mm
be 5

c/c dist. = 2000mm


be = 1800mm
Since the BM is very large, assume two layers of 26 steel.
d1 = 26+8+26+13 = 73mm 75mm.
d = D-d1 = 400-75 = 325mm
Check T-beam (assuming b = be)
4M d
Kx = 0.5 c1 c1
2

be d 2 c 2

4 * 500 * 106
= 0.5 2.5 2.52 2
1800 * 325 * 3.616

= 0.336 < kxmax.


X = kxd = 0.336*325 = 109.23mm>kf
T-section
Mdf = (be-bw)hf fcd (d-hf/2)
= (1800-400)*80*11.3*(325-80/2)*10-6
= 360.70kNm.
M df 360.70 * 10 6
Asf =
4852mm 2
h 80
f yd (d f ) 260.87 * (325 2 )
2
1 2 4 M dw
Kw = c1 c1 Mdw = Md-Mdf
2 bw d 2 c 2

= 500-360.7
= 139.3kNm

1
4 * 139.3 * 10 6
Kw = 2.5 2.5 2
2 = 0.443<0.448 (singly reinforced)
2
400 * 325 * 3.616

kw 0.443
Asw = bw d * 400 * 325 2003mm
2

m 28 . 78
As = Asf + Asw = 4852 + 2003 = 6855mm2
6855
#26 = 12.93 say 13.
530
Use 13 26 bars in two layers.

2
1800mm

80mm

400mm 1326

400mm

Example 4.2
For the T-section singly reinforced with high strength steel (fy = 460N/m2) calculate the
design moment capacity of the section.
Assume the grade of concrete as c-30.

1200mm

120mm

400mm 1224

70mm

350mm

Solution
460
Analysis: fyk = 460MPa fyd = = 400MPa
1.15
C-30 fcd = 13.6Mpa.
f yd 400
M= = 36.76
0.8 f cd 0.8 * 13.6

d = 120 + 400 = 520mm.


be = 1200mm
As = 12*452 = 5424mm2
As 5424
= = 0.008694.
bed 1200 * 520
X = md = 0.00869 * 36.76 * 520 = 166mm

3
Y = 0.8x = 0.8*166 = 133mm> 120mm
T-section analysis is required.
Mdf = (be-bw)hf fcd Zf
hf
Zf = d- = 520- 120 = 410mm
2 2
Mdf = (1200-350)*120*13.6*410*10-6
= 568.75kNm.
M df 568.75 * 10 6
Asf = = 3468mm2
Z f f yd 410 * 400

Asw = As-Asf = 5424-3468 = 1956mm2


a sw 1956
w = = 0.01075
bw d (350)(520)

Kw = mw = 36.76*0.01075 = 0.395<kxmax
Mdw = 0.8 bwd2 fcd kw (1-0.4kw)
= 0.8*350*5202*13.6*0.395*(1-0.4*0.395)*10-6
= 342.51kNm.
Md = Mdf + Mdw = 568.75 + 342.51
= 911.26kNm

Example 6.1

4
A propped cantilever bam is subjected to a live load of 14kN/m an dead load of 5kN/m
(including self weight), both uniformly distributed. If it has a cross-section of 300 x
500mm,
(a) Determine the amounts of reinforcements at the critical sections.
(b) Show in sketch the curtailment and anchorage of the bars if only 30% of the +ve
reinforcements and 30% of the negative reinforcements are to be extended up to the
supports (see fig. below) use materials 16 for main reinforcement, 6 for stirrups of S-
400 and concrete of grade C-30.

300mm

300mm

300mm 300mm

7m

Solution
Material strengths:
C- 30 fcd = 13.6MPa.
S- 400 fyd = 348MPa.
16 and 6 are to be used.
Load:

DL 5kN / m
Pd = 1.3DL + 1.6LL = 28.90kN/m
LL 14kN / m
Analysis
28.90kNm

7m

Critical moments:

5
wl 2 28.9 * 7 2
-ve BM , M =
8 8
+ve BM,
28.90kNm

R1 R2
177kNm

28.9 * 72 1
R2 = 177 = 75.86kN.
2 7

28.9 x 2 dM
Mx = 75.86X- 75.86-28.9X = 0
2 dx
75.86
X= = 2.625m
28.9
28.9 * 2.625 2
Mmax = 75.86 * 2.625- 99.56kNm
2
Amounts of reinforcements.
Assume d1 = 40mm d = D-d1
D = 500-40 = 460mm
dused = 460mm , d1 = 25+6+8 0 39mm< 40mm ok!
Check d
M
d=
0.8 f cd bk x max (1 0.4k x max )

177 * 10 6
d=
0.8 * 13.6 * 300 * 0.448 * (1.04 * 0.448)

d = 384mm < 460mmsafe.


-ve reinforcement M = 177kNm
M K
As = f d (1 0.4k ) or As = x bd
y x m
C1 = 2.5 C2 = 0.32fcd = 4.352
m = fyd/0.8fcd = 32

4M d 4 * 177 *10 6
Kx = 0.5 c1 c1 2 0.52.5 2.52
2

bd c 2 300 * 460 2 * 4.362

+ve reinforcement M = 99.56kNm

6

4 * 99.56 * 10 6

Kx = 0.5 2.5 2.5
2
2

300 * 360 * 4.352
= 0.1536 <Kxmax
0.1536
As = * 300*460 = 662mm2
32
662
# 16 = = 3.3
200
use 416 for max. Moment in the span.
Curtailment of bars:
Basic anchorage length
fyd
lb = for fck = 24MPa
4 fbd

fbd = 2.6MPa
fbd = 2fctd (EBES-2)
0.21 f 2 3
fbd = 2*
ck 0.28 f 0.28( 24) 2 3
1.5 ck

fbd = 2.33MPa.
16 348
lb = * =597mm
4 2.33
For ve reinforcement
As ,cal = 1251mm2
As,prov = 7*200 = 1400mm2
For straight anchorage a =1.0
As ,cal 1251
Lb,net = a lb = 597* = 533mm>d safe
As , prov 1400

But the column can accommodate only


16
300-(25+ ) = 267mm<533mm
2
Hence hooking is recommended:
a = 0.7
Lb,net = 0.7*533 = 373mm

Using 900 bend

7
267m
m

lt

Lt + 267 = lb,net = 373


Lt 373-267 106mm
Use lt = 110mm 5 = 80mm ok!
70% of ve reinforcements are to be curtailed only 30% are to be extended capable of
resisting 0.3Mneg. Location of curtailment.

28.9kmN
177kNm m
28.9 x 2
M = 177 + 126.44 X
2
M = 0.3*177
126.44kNm X

0.3*177 = 177+14.45X2-126.44X
X2-8.75X + 8.574 = 0

X=
1
2

8.75 8.75 2 4 * 8.574 = 1.124m

Cut off point from the face of support will be X + lb,net = 1124 + 533 = 1657mm
70% bar means 0.7*7 = 4,95 bars.
The length of these five bars:
lcut = 1657 + 267 + 110 = 2034mm.
Take lcut = 2040mm
1930m

110

Those bars extended to the end (2bars)


lend = (7000-25)+267+110+150 = 7502
Use lend = 7500
For +ve reinforcement
As,cal = 662mm2
As,prov = 4*200 = 800mm2
For straight anchorage a = 1.0

8
As ,cal 662
lb,net = alb 597 * = 494mm> d
As , prov 800

There are only 4 bars


Extending only 30% means # bars = 0.3*4 = 1.2< 2.
Ate least 2 bars must be extended this means 50% of the bars. Curtailment loation for
these 50% bars means, the moment M = 0.5Mpos.
Mpos = 99.56kNm
0.5Mpos = 177 + 14.45x2-126.44x
-0.5*99.56 = 177 + 14.45x2 -126.44x
X2-8.75X + 15.694 = 0

X=
1
2

8.75 8.75 2 4 *15.694
X1 = 2.52m, X2 = 6.23m
(left end) (right end)
The length of the two cut bars will be
Lcut = (x2-x1) + 2lb,net = (6.23-2.52)+2*0.494
4.70m.
The remaining 2 bars extended to the support are anchored similar to the ve
reinforcements.
Lend = 7.35m lb,net = 0.7*494 = 346mm.

9
Bar No. of Bar size Bar length Bar shape(mm)
type bars ,(mm) (mm)
1 5 16 2040 1930
110
2 2 16 7500 7390
110
3 2 16 4700
4700
4 2 16 7350
80
7270

Location of Zero moment from fixed support


M=0
0 = 177 + 14.45X2-126.44X
X2-8.75X+12.25 =

X=
1
2

1
8.75 8.75 2 4 * 12.25 (8.75 5.25)
2
= 1.75m
Except 2 bars which must extend up to support ends both positive and negative
reinforcements are cut by extending with lb,net from this location.

10