J1000
The basic inverter
V/f controlled inverter
Good torque performance (150% / 3 Hz)
Double rating ND 120%/1min and HD 150%/1 min
Overload detection function (150% during 60s)
Motor thermal function
Freely configurable V/f curve
5 programmable digital input
1 programmable digital output
1 programmable analog output
Optional RS-232C/485 communication - Modbus,
CE, UL, cUL and TUV, RoHS
Ratings
200 V Class single-phase 0.1 to 1.5 kW
200 V Class three-phase 0.1 to 4.0 kW
400 V Class three-phase 0.2 to 4.0 kW
System configuration
Power
Supply
MCCB
it
Un
py
Co
B R
US ER
M
CO
CX-One
ify
Adapter
Ver
ad
Re
CK
LO A
KAW
81 YAS
P-1
JVO
AC Reactor
Filter
Communication Unit
J1000
Mounting Accesories
Choke
Braking Resistor
Motor
DC Reactor
Ground
J1000 1
Specifications
Type designation
JZAB0P1BAA
Version
Coating specs:
J1000 series A: Standard
~
4: Three-phase 400 VAC
4P0: 4 kW
200 V class
Single-phase: JZA@ B0P1 B0P2 B0P4 B0P7 B1P5 - -
Three-phase: JZA@ 20P1 20P2 20P4 20P7 21P5 22P2 24P0
Motor For HD setting 0.12 0.25 0.4 1.1 1.5 2.2 4.0
kW1 For ND setting 0.18 0.37 0.55 1.1 2.2 3.0 5.51
characteristics
Inverter capacity kVA 0.3 0.6 1.1 1.9 3.0 4.2 6.7
Rated output current (A) at HD 0.8 1.6 3.0 5.0 8.0 11.0 17.5
Output
Rated output current (A) at ND 1.2 1.9 3.5 6.0 9.6 12.0 21.0
Max. output voltage Proportional to input voltage: 0..240 V
Max. output frequency 400 Hz
Rated input voltage Single-phase 200..240 V 50/60 Hz
and frequency 3-phase 200..240 V 50/60 Hz
supply
Power
400 V class
Three-phase: JZA@ 40P2 40P4 40P7 41P5 42P2 43P0 44P0
Motor For HD setting 0.37 0.55 1.10 1.5 2.2 3.0 4.0
kW1 For ND setting 0.37 0.75 1.5 2.2 3.0 4.0 5.5
characteristics
Inverter capacity kVA 0.9 1.4 2.6 3.7 4.2 5.5 7.2
Rated output current (A) at HD 1.2 1.8 3.4 4.8 5.5 7.2 9.2
Output
Rated output current (A) at ND 1.2 2.1 4.1 5.4 6.9 8.8 11.1
Max. output voltage 0..480V (proportional to input voltage)
Max. output frequency 400 Hz
Rated input voltage
3-phase 380..480 VAC, 50/60 Hz
and frequency
supply
Power
Allowable voltage
-15%..+10%
fluctuation
Allowable frequency
+5%
fluctuation
1. Based on a standard 4-pole motor for maximum applicable motor output:
Heavy Duty (HD) mode with a 150% overload capacity
Normal Duty (ND) mode with a 120% overlaod capacity
2 Frequency inverters
Specifications
Commom specifications
Model number
Specifications
JZA@
Control methods V/f control
Output frequency range 0.1..400 Hz
Digital set value: 0.01% (-10..+50 C)
Frequency tolerance
Analogue set value: 0.1% (25 10 C)
Control functions
eration mode, inverter run ready, during fault retry, reverse running, during speed search.
Full-range automatic torque boost, slip compensation, 9-step speed operation (max.), restart after momentary power loss,
DC injection braking current at stop/start (50% of inverter rated current, 0.5 sec, or less), frequency reference bias/gain, ME-
Standard functions
MOBUS communications (Option), fault retry, speed search, frequency upper/lower limit setting, overtorque detection, fre-
quency jump, accel/decel time switch, accel/decel prohibited, S-curve accel/decel
Analogue inputs 1 analogue input, 0..10 V, 4..20 mA, 0..20 mA
Braking/acceleration times 0.01..6000 s
Optionally frequency, current or set value
Display
Error and status LED
Motor overload protection Electronic thermal overload relay
Instantaneous overcurrent Motor coasts to a stop at approx. 250% of inverter rated current
Heavy Duty: Motor coasts to a stop after 1 minute at 150% of inverter rated output current
Overload
Protection functions
Normal Duty: Motor coasts to a stop after 1 minute at 120% of inverter rated output current
Overvoltage Motor coasts to a stop if DC bus voltage exceed 410 V (double for 400 V class)
Stops when DC bus voltage is approx. 190 V or less (double for 400 V class)
Undervoltage
(approx. 150 V or less for single-phase series)
Following items are selectable: not provided (stop if power loss is 15 ms or longer), continuous operation if power loss is
Momentary power loss
approx. 0.5 s or shorter, continuous operation
Cooling fin overheat Protected by thermistor
Stall prevention level Stall prevention during acceleration/deceleration and constant speed operation
Ground fault Protected by electronic circuit (operation level is approx. 250% of rated output current)
Power charge indication Indicates until the main circuit voltage reaches 50 V.
Degree of protection IP20, NEMA1
Ambient conditions
Cooling fan is provided for 200 V (3-phase) 0.75 kW (1HP) to 4.0 KW, 200V (single-phase) 1.5 KW
Cooling
400 V 1.5 kW (2HP) to 4.0 KW, others are self-cooling
Ambient humidity 95% RH or less (without condensation)
Storage temperature -20 C..+60 C (short-term temperature during transportation)
Installation Indoor (no corrosive gas, dust, etc.)
Installation height Max. 1000 m
Vibration Up to 9.8 m/s2 at 10 to less than 20 Hz, Up to 6.37 m/s2 at 20 to 50 Hz
J1000 3
Dimensions
IP 20 type 0.1 to 4 kW
Figure 1 Figure 2
D2
W1 2-M4 t1 W1 4-M4 D2
H1
H
H1
H
H2
D1 t1
H2
W
W D1
D
D
Dimensions Weight
Schaffner model
A B C D E F G H I J K L KG
A1000-FIV2010-SE 194 82 50 160 181 62 5.3 M5 25 56 118 M4 0.40
3x200 V A1000-FIV2020-SE 169 111 50 135 156 91 5.5 M5 25 96 118 M4 0.58
A1000-FIV2030-SE 174 144 50 135 161 120 5.3 M5 25 128 118 M4 0.90
A1000-FIV1010-SE 169 71 45 135 156 51 5.3 M5 22 56 118 M4 0.44
1x200 V
A1000-FIV1020-SE 169 111 50 135 156 91 5.3 M5 25 96 118 M4 0.75
A1000-FIV3005-SE 169 111 45 135 156 91 5.3 M5 22 96 118 M4 0.5
3x400 V A1000-FIV3010-SE 169 111 45 135 156 91 5.3 M5 22 96 118 M4 0.7
A1000-FIV3020-SE 174 144 50 135 161 120 5 M5 25 128 118 M4 0.9
4 Frequency inverters
Rasmi footprint Filters
Dimensions Weight
Rasmi model
W H L X Y M KG
A1000-FIV2010-RE 82 50 194 181 62 M4 0.8
3x200 V A1000-FIV2020-RE 111 50 194 181 62 M4 1.1
A1000-FIV2030-RE 144 50 174 161 120 M4 1.3
A1000-FIV1010-RE 71 45 169 156 51 M4 0.6
1x200 V
A1000-FIV1020-RE 111 50 169 156 91 M4 1.0
A1000-FIV3005-RE 111 45 169 156 91 M4 1.1
3x400 V A1000-FIV3010-RE 111 45 169 156 91 M4 1.1
A1000-FIV3020-RE 144 50 174 161 120 M4 1.3
Chokes
X
Description D Motor Dimensions Weight
diameter KW L W H X Y m Kg W Y m
A1000-FEV2102-RE 21 < 2.2 85 22 46 70 - 5 0.1
A1000-FEV2515-RE 25 < 15 105 25 62 90 - 5 0.2 L
H d
Resistor Dimensions
A1000-REJ0K15xxx A1000-REJ0K10xxx
168
27 105
11.5 182
36
45
20
J1000 5
DIN rail mounting bracket
EZZ08122A EZZ08122B
DIN rail
35.1
Four, M4 tap Four, M4 tap
Side view
(common to
all the units)
EZZ08122C
Four, M4 tap
6 Frequency inverters
Installation
Standard connections
R/L1 R/L1 U
Three phase U/T1
power supply S/L2 S/L2 Main circuit V
200 to 240 V V/T2 M
T/L3 T/L3 W
Control circuit W/T3
<4>
Forward run/stop S1
2 MCCB THRX OFF ON MC
Ground
SA Reverse run/stop S2 10 or less (400 V class)
MC Option unit 100 or less (200 V class)
THRX External fault S3 connector
MB
Digital inputs 24 V
(default setting) <5> Sink MC
DIP
switch S3 Source
SC
Shield ground
terminal
Main circuit
Terminal Name Function (signal level)
Main circuit power supply input Used to connect line power to the drive.
R/L1, S/L2, T/L3 Drives with single-phase 200 V input power use only terminals R/L1 and S/L2
(T/L3 is not connected to anything)
U/T1, V/T2, W/T3 Inverter output Used to connect the motor
B1, B2 Braking resistor connection Available for connecting a braking resistor or the braking resistor unit option.
+2, +1 DC reactor connection Remove the short bar between +2 and +1 when connecting DC reactor (option)
+1, DC power supply input For power supply input (+1: positive electrode; : negative electrode)*
Grounding For grounding (grounding should conform to the local grounding code.)
J1000 7
Control Circuit
Type No. Signal name Function Signal level
S1 Multi-function input selection 1 Factory setting: runs when CLOSED, stops when OPEN.
S2 Multi-function input selection 2 Factory setting: runs when CLOSED, stops when OPEN.
Digital S3 Multi-function input selection 3 Factory setting: External Fault (N.O.) 24 VDC, 8 mA
input photocoupler
signals S4 Multi-function input selection 4 Factory setting: Fault reset insulation
S5 Multi-function input selection 5 Factory setting: Multi-step speed cmd 1
SC Multi-function input selection Common Common for control signal
FS Power Supply for Frequency Setting +10 V (allowable max current 20 mA)
Analog Voltage input or current input
input FR1 Main Speed Freq Ref 0 to +10 VDC (20 k) (resolution 1/1000)
signal 4 to 20 mA (250 ) or 0 to 20 mA (250 ) Resolution: 1/500
FC Frequency reference common 0V
MA NO contact output Contact capacity
Digital
output MB NC Output Factory setting: "fault" 250 VAC, 1 A or less
signals Relay Output common 30 VDC, 1 A or less
MC
Analog AM Analog monitor output Factory setting: "output frequency" 0 to +10 V output Resolution: 1/1000 0 to 10 V 2 mA or less
output
signals AC Analog monitor common 0V Resolution: 8 bits
A B 2 mm B
C
HD
ND
HD
ND
8 Frequency inverters
Three-phase 400 V class
Model JZA 40P2 40P4 40P7 41P5 42P2 43P0 44P0
Inverter capacity kVA 0.9 1.4 2.6 3.7 4.2 5.5 7.2
Rated current (A) at HD 1.2 1.8 3.4 4.8 5.5 7.2 9.2
Rated current (A) at ND 1.2 2.1 4.1 5.4 6.9 8.8 11.1
Fin 19.2 28.9 42.3 70.7 81.0 84.6 107.2
loss W
Heat
HD
ND
Power
supply MCCB MC
R/L1 B1 B2
S/L2 U/T1
T/L3 V/T2 Motor
W/T3
THRX OFF ON MC
JZ
SA
MC
THRX
SA
Thermal relay switch for
external braking resistor
MC TRX
SA
TRX
FLT-A FLT-B
Fault contact
AC reactor
200 V class 400 V class
Max. applicable Current
Inductance Max. applicable
Current
Inductance AC reactor JZ
motor output value motor output value
mH mH
kW A kW A
0.12 2.0 2.0 ------ Power supply MCCB U X R/L1
0.25 2.0 2.0 0.2
1.3 18.0 V Y S/L2
0.55 2.5 4.2 0.4
1.1 5 2.1 0.75 2.5 8.4 W Z T/L3
1.5 10 1.1 1.5 5 4.2
2.2 15 0.71 2.2 7.5 3.6
4.0 20 0.53 4.0 10 2.2
DC reactor
200 V class 400 V class JZ
Max. applicable Current Inductance Max. applicable Current Inductance
Power
motor output value motor output value supply MCCB
mH mH R/L1
kW A kW A
S/L2
0.12 --------
T/L3
0.25 0.2
5.4 8
0.55 0.4 3.2 28
1.1 0.75 +1 +2
1.5 1.5
5.7 11
2.2 18 3 2.2
4.0 4.0 12 6.3 DC reactor
J1000 9
Ordering information
Power
Supply C
RS232 Communications cable with PC
D
MCCB
US
M
B
Co
py
ER
Un
R
it
C C
CO
py
Co
CX-One
ify
Adapter
Ver
ad
Re
CK
LO A
KAW
81 YAS
P-1
JVO
AC Reactor
C C
Remote Operator LED Remote
Extansion Cable Operator
A
Filter
B
Communication Unit
F
J1000
Mounting Accesories
A
Choke E
Braking Resistor
Motor
DC Reactor
Ground
J1000
Specifications Model
Heavy Duty Normal Duty Standard
0.12 kW 0.8 A 0.18 kW 0.8 A JZAB0P1BAA
0.25 kW 1.6 A 0.37 kW 1.6 A JZAB0P2BAA
1x200 V 0.55 kW 3.0 A 0.75 kW 3.5 A JZAB0P4BAA
1.1 kW 5.0 A 1.1 kW 6.0 A JZAB0P7BAA
1.5 kW 8.0 A 2.2 kW 9.6 A JZAB1P5BAA
0.12 kW 0.8 A 0.18 kW 0.8 A JZA20P1BAA
0.25 kW 1.6 A 0.37 kW 1.6 A JZA20P2BAA
0.55 kW 3.0 A 0.75 kW 3.5 A JZA20P4BAA
3x200 V 1.1 kW 5.0 A 1.1 kW 6.0 A JZA20P7BAA
1.5 kW 8.0 A 2.2 kW 9.6 A JZA21P5BAA
2.2 kW 11.0 A 3.0 kW 12.0 A JZA22P2BAA
4.0 kW 17.5 A 5.5 kW 21.0 A JZA24P0BAA
0.37 kW 1.2 A 0.37 kW 1.2 A JZA40P2BAA
0.55 kW 1.8 A 0.75 kW 2.1 A JZA40P4BAA
1.1 kW 3.4 A 1.5 kW 4.1 A JZA40P7BAA
3x400 V 1.5 kW 4.8 A 2.2 kW 5.4 A JZA41P5BAA
2.2 kW 5.5 A 3.0 kW 6.9 A JZA42P2BAA
3.0 kW 7.2 A 4.0 kW 8.8 A JZA43P0BAA
4.0 kW 9.2 A 5.5 kW 11.1 A JZA44P0BAA
10 Frequency inverters
A Line filters
Inverter Line filter Schaffner Line filter Rasmi
Voltage Model JZA@ Reference Rated current (A) Weight (kg) Reference Rated current (A) Weight (kg)
20P1 / 20P2 / 20P4 / 20P7 A1000-FIV2010-SE 10 0.7 A1000-FIV2010-RE 10 0.8
3-Phase
21P5 / 22P2 A1000-FIV2020-SE 20 0.9 A1000-FIV2020-RE 20 1.1
200 VAC
24P0 A1000-FIV2030-SE 30 1.0 A1000-FIV2030-RE 30 1.3
Single-Phase B0P1 / B0P2 / B0P4 A1000-FIV1010-SE 10 0.5 A1000-FIV1010-RE 10 0.6
200 VAC B0P7 / B1P5 A1000-FIV1020-SE 20 0.7 A1000-FIV1020-RE 20 1.0
40P2 / 40P4 A1000-FIV3005-SE 5 0.5 A1000-FIV3005-RE 5 1.1
3-Phase
40P7 / 41P5 / 42P2 / 43P0 A1000-FIV3010-SE 10 0.75 A1000-FIV3010-RE 10 1.1
400 VAC
44P0 A1000-FIV3020-SE 15 1.0 A1000-FIV3020-RE 20 1.3
A Chokes
Model Diameter Description
A1000-FEV2102-RE 21 Recommended for motors below 2.2 KW
A1000-FEV2515-RE 25 Recommended for motors below 15 KW
B Communication cards
Type Model Description Function
RS232C communications interface to connect the drive to a PC or the
SI-232/JC RS-232C serial communication interface
optional copy unit
Option units
C Accessories
Types Model Description Functions
operator
JVOP-182 LED remote operator Remote operator with LED display and copy function, cable length max. 3m.
Digital
A1000-CAVOP300-EE Remote operator cable 3 meters cable for connecting remote operator
Allows the user to copy and verify parameter settings between drives. Can
Accessories
JVOP-181 USB converter / USB cable also be used as adapter to connect the drive to a PC USB port. SI-232/JC
option is required
A1000-CAVPC232-EE PC connection cable RS232 PC tool connection cable
D Computer software
Types Model Description Installation
Software
J1000 11
F Mounting accesories
Types Model Description Applicable models JZA@
20P1/20P2/20P4/20P7
EZZ08122A
B0P1/B0P2/B0P4
21P5/22P2
DIN Rail
100-034-076
B0P4
100-034-077 20P7
100-034-078 40P2
Additional items to mount the inverter with 21P5/22P2
100-034-79 the heatshink out of the panel. B1P5
41P5/42P2/43P0
24P0
100-034-80 B2P2
44P0
100-036-357 B4P0
B0P7
100-036-418
40P4/40P7
Cat. No. I81E-EN-01A In the interest of product improvement, specifications are subject to change without notice.
12 Frequency inverters