Arup FS
Arup FS
Simplified Method of bending moment and shear forces for flat slabs of 3 or more equal spans
Near Centre First Interior Centre of Interior
of first span Support Interior Span Support
Moment in X-direction, Mx 334 -290 281 -188
Moment in Y-direction, My 334 -290 281 -188
Shear - 411 - 343
Total Column Moment - - - -
A. INPUT DATA
Column Location = Internal Shear Perimeter
Concrete 28 D Strength fcu = 35 N/mm2
Main Steel Strength fy = 460 N/mm2
Links Strength fyv = 410 N/mm2 1.5d
Concrete Cover, c = 30 mm Edge
Slab Thickness, h = 275 mm Column
Column Size, Cx (Main) = 903 mm Location Cy (Dist) Y (Dist)
Cy (Dist) = 903 mm = 1579
Effective depth, dx = 238.5 mm Cx (Main)
dy = 226 mm
(fcu/25)1/3 = 1.119
vc = 0.534 N/mm2
Successive
perimeters
loaded
area
Zone 1
The figure show the location of sucessive perimeters and
failure zones. A typical failure zone (zone 3) is shown
shaded together with the notional failure associated with
Zone 2
the zone.
Zone 3
At least two sets of reinforcement should intersect the
Zone 4
notional failure within each zone.
S.B.T CONSULTANTS +ACCREDITED CHECKERS
av = 1.5d = 348 mm
Asv req = No shear links required. Note : 1. v-vce shall not less than 0.4 N/mm2.
= 0 mm2 2. Links shall be provided within Zone 1
Place links within = 150 & 300 mm fr. support face
Inner Perimeter, U1 = 4810.81 mm 1st Perimeter of shear links
Outer Perimeter, U2 = 6011 mm 0.5d = 116 mm
2nd Perimeter, < 0.75d way fr. the 1st
Tot. Nos of Links req = 0 legs 1.25d = 290 mm
Tot. Links req in U1 = 0 legs, Min Link's Spacing, Sv ### mm c/c
Provide T 8 - 185 c/c 26.0 legs ###
av = 2.25d= 522 mm
Asv req = No shear links required. Note : 1. v-vce shall not less than 0.4 N/mm2.
= 0 mm2 2. Links shall be provided within Zone 2
Place links within = 300 & 550 mm fr. support face 3rd Perimeter, = 2nd Perimeter
Inner Perimeter, U2 = 6010.81 mm = 300 mm
Outer Perimeter, U3 = 8011 mm 4th Perimeter, < 0.75d away fr. the 3rd
= 474 mm
Tot. Nos of Links req = 0 legs
Tot. Links req in U2 = 32 legs, Min Link's Spacing, Sv 188 mm c/c
Provide T 8 - 185 c/c
Tot. Links req in U3 = -32 legs, Min Link's Spacing, Sv -250 mm c/c
Provide T 8 - 237 c/c 33.8 legs OK
S.B.T CONSULTANTS +ACCREDITED CHECKERS
av = 3.0d = 696 mm
Asv req = No shear links required. Note : 1. v-vce shall not less than 0.4 N/mm2.
= 0 mm2 2. Links shall be provided within Zone 2
Place links within = 550 & 700 mm fr. support face 5th Perimeter, = 4th Perimeter
Inner Perimeter, U3 = 8010.81 mm = 550 mm
Outer Perimeter, U4 = 9211 mm 6th Perimeter, < 0.75d away fr. the 5th
= 724 mm
Tot. Nos of Links req = 0 legs
Tot. Links req in U3 = 33 legs, Min Link's Spacing, Sv 243 mm c/c
Provide T 8 - 237 c/c
Tot. Links req in U4 = -33 legs, Min Link's Spacing, Sv -279 mm c/c
Provide T 8 - 200 c/c 46.1 legs OK
av = 3.75d= 870 mm
Asv req = No shear links required. Note : 1. v-vce shall not less than 0.4 N/mm2.
= 0 mm2 2. Links shall be provided within Zone 2
Place links within = 700 & 850 mm fr. support face 7th Perimeter, = 6th Perimeter
Inner Perimeter, U4 = 9210.81 mm = 700 mm
Outer Perimeter, U5 = 10411 mm 8th Perimeter, < 0.75d away fr. the 7th
= 874 mm
Tot. Nos of Links req = 0 legs
Tot. Links req in U4 = 46 legs, Min Link's Spacing, Sv 200 mm c/c
Provide T 8 - 200 c/c
Tot. Links req in U5 = -46 legs, Min Link's Spacing, Sv -226 mm c/c
Provide T 8 - 200 c/c 52.1 legs OK