0% found this document useful (0 votes)
147 views7 pages

Vertical Weld Design Bolt Design'!A1 Deflection!A1 Material Data'!a1 Index!a1 Trang

This document contains design calculations for a vertical barrier at the Student Care Centre at 300 Tanglin Halt Road project. It includes: 1. Calculations of internal forces on the barrier from different load cases and determination of controlling bending moment and shear force. 2. Section properties and checking of the proposed 50x50x3mm SHS section for flexure, shear, and deflection. 3. Similar calculations for a fixed condition with the barrier pinned at two supports. 4. Weld design calculations for connecting the vertical barrier to a base plate, checking a 3mm fillet weld is adequate. 5. Brief mention of Hilti bolt design for connecting the barrier to
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
147 views7 pages

Vertical Weld Design Bolt Design'!A1 Deflection!A1 Material Data'!a1 Index!a1 Trang

This document contains design calculations for a vertical barrier at the Student Care Centre at 300 Tanglin Halt Road project. It includes: 1. Calculations of internal forces on the barrier from different load cases and determination of controlling bending moment and shear force. 2. Section properties and checking of the proposed 50x50x3mm SHS section for flexure, shear, and deflection. 3. Similar calculations for a fixed condition with the barrier pinned at two supports. 4. Weld design calculations for connecting the vertical barrier to a base plate, checking a 3mm fillet weld is adequate. 5. Brief mention of Hilti bolt design for connecting the barrier to
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 7

vertical

weld design
BOLT DESIGN'!A1
DEFLECTION!A1
material data'!A1
index!A1
trang
project title: STUDENT CARE CENTRE AT 300 TANGLIN HALT ROAD
client CPG
designed by TRANG
checked by BKT STUDENT CARE CENTRE AT 300 TANGL
CODE:
JOB: VERTICAL BARRIER

50x50 x 2.5 2.5 3.71


50x50 x 3 3 4.39
50x50 x 3.2 3.2 4.66
50x50 x 4 4 5.72
50x50 x 5 5 6.97
50x50 x 6 6 8.15
50x50 x 6.3 6.3 8.49

50x50 x 6 10.2
50x50 x 5 8.73
5.72 #N/A
50x50 x 4
CENTRE AT 300 TANGLIN HALT ROAD

4.68 17.5 1.93 6.99 8.29 27.5 10.2 0.194


5.54 20.2 1.91 8.08 9.7 32.1 11.8 0.192
5.88 21.2 1.9 8.49 10.2 33.8 12.4 0.192
7.19 25 1.86 9.99 12.3 40.4 14.5 0.19
8.73 28.9 1.82 11.6 14.5 47.6 16.7 0.187
10.2 32 1.77 12.8 16.5 53.6 18.4 0.185
10.6 32.8 1.76 13.1 17 55.2 18.8 0.184
BKTAN CONSULTANTS
PROJECT STUDENT CARE CENTRE AT 300 TANGLIN HALT ROAD
Designed by: Date:
CLIENT CPG TRANG 9/11/2017
CODE Checked by: Revision:
JOB 50x50x3mmTHK SHS VERTICAL BAR BKT 1

STATUS DESIGN: VALID DESIGN

Type of occupancy of building: C3 (table 4- BS6399:Part 1: 1996)


Location of barrier: (case) viii
Structural diagram: Cantilever Span: L= 1.1 m
Load span: 0.9 m
Material:
Material of barrier: Steel g= 78 kN/m3
p y= 275 N/mm2
E= 205 kN/mm2
Factored load: FOS: 1.5

Determine internal force:


Case 1: Point load of : 0.5 kN
Mu= 0.83 kNm
Pu= 0.75 kN

Case 2: Uniformly distributed load of: 0.74 kN/m


Mu= 0.67 kNm
Pu= 1.22 kN

Case 3: Areal load of: 1 kN/m2


Mu= 0.82 kNm
Pu= 1.49 kN
Mu control= 0.83 kNm
Pu control= 1.49 kN

Section property: 50 x 50 x 3 mmTHK SHS


A= 5.64 cm2
Ix-x= 20.85 cm4
Z x= 6.64 cm3

Checking: Flexure checking Shear checking


Mc=py*Z= 1.82 kNm Pv=0.6pyAv= 93.06 kN
Mc > Mmax Pv > Vmax
Satisfied Satisfied

Deflection checking: = 3.17 mm < a= 6.11 mm


Satisfied
BKTAN CONSULTANTS
PROJECT STUDENT CARE CENTRE AT 300 TANGLIN HALT ROAD
Designed by: Date:
CLIENT CPG TRANG 9/11/2017
CODE Checked by: Revision:
JOB 50x50x3mmTHK SHS VERTICAL BAR BKT 1

STATUS DESIGN: VALID DESIGN

Type of occupancy of building: C3 (table 4- BS6399:Part 1: 1996)


Location of barrier: (case) viii
Structural diagram: Pined at two support Span: L= 0.9 m
Load span: 1.1 m
Material:
Material of barrier: Steel g= 78 kN/m3
p y= 275 N/mm2
E= 205 kN/mm2
Factored load: FOS: 1.5

Determine internal force:


Case 1: Point load of : 0.5 kN
Mu= 0.17 kNm
Pu= 0.38 kN

Case 2: Uniformly distributed load of: 0.74 kN/m


Mu= 0.11 kNm
Pu= 0.50 kN

Case 3: Areal load of: 1 kN/m2


Mu= 0.17 kNm
Pu= 0.74 kN
Mu control= 0.17 kNm
Pu control= 0.74 kN

Section property: 50 x 50 x 3 mmTHK SHS


A= 5.64 cm2
Ix-x= 20.85 cm4
Z x= 6.64 cm3

Checking: Flexure checking Shear checking


Mc=py*Z= 1.82 kNm Pv=0.6pyAv= 93.06 kN
Mc > Mmax Pv > Vmax
Satisfied Satisfied

Deflection checking: = 0.15 mm < a= 4.5 mm


Satisfied
BKTAN CONSULTANTS
PROJECT STUDENT CARE CENTRE AT 300 TANGLIN HALT ROAD
Designed by: Date:
CLIENT CPG TRANG 9/11/2017
CODE Checked by: Revision:
JOB WELD DESIGN BKT 1

STATUS DESIGN: VALID DESIGN

Position of weld connection: vertical bar-TB1


Design strength of fillet weld pw(N/mm2): 215 N/mm2
Welding section: 50 x 50
Iu= 83341.67 mm4
Wu= 3333.7 mm3
Length of welding L= 200 mm
Thickness of weld s= 3 mm

Internal force:
From vertical sheet:
M u= 0.825 kN.m Vu= 1.49 kN

Design fillet weld:


FS due to shear force Vu: Fs=Vu/L= 7.45 N/mm

FT due to moment Mu: FT=Mu/W= 247.5 N/mm

Resultant shear: FR=(Fs2+FT2)1/2= 247.6 N/mm

CHECK FOR 3mm WELD SIZE


PL=0.7spw= 451.5 N/mm > FR Satisfied
BKTAN CONSULTANTS
PROJECT STUDENT CARE CENTRE AT 300 TANGLIN HALT ROAD
Designed by: Date:
CLIENT CPG TRANG 9/11/2017
CODE Checked by: Revision:
JOB HSA HILTI BOLTS DESIGN BKTAN 1

DESIGN STATUS: VALID DESIGN


Position of Hilti bolts connection: vertical bar- base plate

Internal force:
From VERTICAL sheet M= 0.825 kNm P= 1.49 kN
f= 12 mm
Total bolts= 4 in 2 rows 2 cols.
Spacing in direction of major stress= 100 mm
Spacing in direction of minor stress= 100 mm
Bolts in shear: 4
Standard embedment depth: 95.0 mm

Determine stress per bolt:


Shear stress due to direct shear
H
Fs= = 0.4 kN
No. of bolts
Tension stress due to bending moment:
M.ymax
FT= = 4.1 kN
y2i

Check with 12mm HSA HILTI BOLTS


Design steel resistence: NRd,s= 29.7 kN > 4.1 kN Satisfied
Design pull out resistence: NRd,p= 16.7 kN > 4.1 kN Satisfied
Design concrete cone resistence: NRd,c= 19.7 kN > 4.1 kN Satisfied

Design shear resistence: VRd,s= 24.4 kN > 0.4 kN Satisfied


Design concrete pryout resistence: VRd,cp= 39.4 kN > 0.4 KN Satisfied
Design concrete edge resistence: VRd,c= 8.8 kN > 0.4 kN Satisfied

Hilti HSA anchor bolt data reference: Hilti Anchor Fastening Technology Manual 2008

HILTI HSA BOLTS


M NRd,s NRd,p NRd,c VRd,s VRd,cp VRd,c
6 6.3 3.3 7.1 5.2 8.5 2.7
8 12 8 11.2 9.6 11.2 4
10 21 10.7 11.9 15.6 23.8 4.8
12 29.7 16.7 19.7 24.4 39.4 8.8
16 50.7 16.7 25.9 44 51.7 12.6
20 89.3 16.7 35.1 68 70.2 18.2