Technical Datas IPS-System ITS-System SAX-System LTB/LTP-System WIPRO-System POCON-System FAME 1-System FAME 2-System FAME 3-System Technical Datas

This document compares the technical specifications of 10 different test plug systems: IPS-System, ITS-System, SAX-System, LTB/LTP-System, WIPRO-System, POCON-System, FAME 1-System, FAME 2-System and FAME 3-System. It provides details on each system's short-circuit current ratings, steady current ratings, voltage ratings, contact resistance, protection class, mounting options, coding and locking capabilities, cable connection options, and manufacturer. The specifications are presented in a table for easy comparison of the test plug systems.

Uploaded by

Ashroof Abdo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
11K views2 pages

Technical Datas IPS-System ITS-System SAX-System LTB/LTP-System WIPRO-System POCON-System FAME 1-System FAME 2-System FAME 3-System Technical Datas

This document compares the technical specifications of 10 different test plug systems: IPS-System, ITS-System, SAX-System, LTB/LTP-System, WIPRO-System, POCON-System, FAME 1-System, FAME 2-System and FAME 3-System. It provides details on each system's short-circuit current ratings, steady current ratings, voltage ratings, contact resistance, protection class, mounting options, coding and locking capabilities, cable connection options, and manufacturer. The specifications are presented in a table for easy comparison of the test plug systems.

Uploaded by

Ashroof Abdo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

The SniffTest | Test Plug Systems compared www.proconplanet.

com 07/2016

www.proconplanet.com

Technical Datas IPS-System ITS-System SAX-System LTB/LTP-System WIPRO-System POCON-System FAME 1-System FAME 2-System FAME 3-System
Conditional short-circuit 500 A / 1 s 500 A / 1 s 500 A / 1 s 500 A / 1s 350 A / 1 s 300 A / 1 s 500 A / 1s 500 A / 1s 500 A / 1s
current:
500 A / 0,3 s 60 A / 6 s
1250 A / 30 ms
Steady current: 20 A 30 A 30 A 25 A 10 A 19 A (Leiter 1 mm) 30 A 30 A 30 A / 10 mm
nominal current 24 A / nominal current 24 A /
6 mm 6 mm
Rated impulse voltage n.i. n.i. n.i. n.i. 5 kV n.i. 4 kV 5 kV 4 kV
according IEC 60664:

Maximum closed-circuit 600 V DC / 500 V AC 600 V n.i. 600 V n.i. 2,21 kV / 50 Hz fr 1 400 V 400 V n.i.
voltage:
min
Nominal voltage: 230 V AC/DC 250 V AC/DC 250 V AC/DC n.i. 250 V AC 250 V AC 400 V AC/DC 400 V AC/DC 400 V AC/DC
Contact resistance: 1,25 m 2 m 2 m 6 m 2 m n.i. n.i. n.i. n.i.
Protection class: IP 20 IP 20 (IP 50 with IP 20 IP 20 IP 20 IP 20 n.i. n.i. n.i.
optional dust cover)
UL94 Flame protection n.i. V-0 V-0 V-0 n.i. n.i. V-0 V-0 V-0
class:

Mounting type: - Wall cutout - Wall cutout - Support rail - Wall cutout - Support rail - Support rail - Support rail - Support rail (optional) - Wall cutout
- Wall connection - Wall connection - Wall connection - Wall connection - Wall connection
(optional Adapter)
Coding capability:
yes yes yes yes yes yes yes yes yes

Locking of the test plug:


no no no yes yes yes nein yes (with rotary yes (with rotary
(Operational plug handle) handle)
yes)
Tension-resistant plug
cabling possible: no no no no yes (By means of yes (By means of yes (By means of yes (By means of yes (By means of
ring- or fork cable ring- or fork cable ring- or fork cable ring- or fork cable ring- or fork cable
shoe) shoe) shoe) shoe) shoe)
Connection type: - Screw connection - Screw for ring- or - Screw for ring- or - Screw connection - Screw connection - Screw connection - Clamp connection - Screw connection - Screw for ring- or
fork cable shoe fork cable shoe - Tension spring - Tension spring - Tension spring fork cable shoe
connection connection connection
Sealing possibility:
no no no no yes no yes (Operational- yes (blind plug) no
&. blind plug)

1
www.proconplanet.com

Technical Datas IPS-System ITS-System SAX-System LTB/LTP-System WIPRO-System POCON-System FAME 1-System FAME 2-System FAME 3-System
Specials: - System since 1958 - Successor of IPS- - STP-Test plug - Lever mechanism - Basic unit for wall - 4, 8 and 9 contacts - With operational - Without operational - Without operational
improved system compatibel for inserting the cut-out and - additional signaling plug plug plug
- 4 opening steps - STP-Test plug - Number of poles LTB test plug support rail contact - Visible bridges - With transformer - With transformer
when inserting the compatible from 4 till 20 - STP-Plug - Number of poles short-circuit within short-circuit within
test plug - 7 till 20 contact- contacs compatible from 1 to 19 the test plug the test plug
- 7, 14 or 19 modules - Long rear end flush possible - Rotary handle within - With additional
contacts with adjacent - Coding against the the test plug service plug
appliances incorrect insertion - Visible bridges - Rotary handle
- 7 or 14 contacts of test plug within the the test
plug
- Visible bridges
Source and manufacturer www.secucontrol.com www.secucontrol.com www.secucontrol.com www.secucontrol.com www.weidmueller.de www.weidmueller.de www.phoenixcontact. www.phoenixcontact.c www.phoenixcontact.
link:
com om com

- All information may be incorrect or incomplete despite careful research, we assume no guarantee. Please contact the manufacturer!