100% found this document useful (1 vote)
876 views13 pages

Flare Calc Sheet API - RP 521

This document contains calculations for an HP flare stack. It provides information on flow rates, temperatures, pressures, and other parameters needed to calculate the flare stack dimensions and safe distances. The calculations are presented in two sections, with the first using a simple approach and the second using Brzustowski's and Sommer's approach. Key results include a flame length of 60 meters, safe distance to the flame centre of 66.836 meters, and a flare height of 41.927 meters for the simple approach and 37.167 meters for the Brzustowski/Sommer approach.

Uploaded by

ionutlaur86
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
876 views13 pages

Flare Calc Sheet API - RP 521

This document contains calculations for an HP flare stack. It provides information on flow rates, temperatures, pressures, and other parameters needed to calculate the flare stack dimensions and safe distances. The calculations are presented in two sections, with the first using a simple approach and the second using Brzustowski's and Sommer's approach. Key results include a flame length of 60 meters, safe distance to the flame centre of 66.836 meters, and a flare height of 41.927 meters for the simple approach and 37.167 meters for the Brzustowski/Sommer approach.

Uploaded by

ionutlaur86
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 13

Flare Stack Calculation Sheet

Simple Approach
Title : Date of Calculation :
HP Flare Calculation ###
Project No : Calculate By :
1131/SKPI-SKPP-2006 Erwin Apriandi

1 Description Symbol Unit


2 Flowrate 75.010 MMscfd
3 88,501.944 m3/hr
4 24.584 m3/s
5 Mass Flow W 90123.000 kg/hr
6 Mol Weigth Mw 24.070
7 Pressure at Flare Tip P2 124.000 kPa
8 Flowing Temperature T 283.900 K
9 Compressibility factor z 1.000
10 Ratio of Specific Heat k 1.210
11 Mach No 0.450
12
13
14 Flare Tip ID 0.404 m
15
16
17 Heat of combustion 47140.000 kJ/kg
18 Heat Liberated Q 1180110.617 kW
19 Flame Length L 60.000 m approx
20
Fig 8 & 9
21 Wind velocity U~ 14.900 m/s
22 Flare Tip velocity Uj 192.276 m/s
23 U~/Uj 0.077
24
25
26 y/L 0.460 approx
27 y 27.600 m
Fig 10
28
29 x/L 0.770 approx
30 x 46.200 m
Fig 10
31
32
33 Fraction Radiated Heat F 0.300
34 1.000
35 Allowable Radiation K 6.310 kW/m2
36 Safe Distance to Flame Centre D 66.836 m
37

Flare Stack Calculation, Erwin A Page 1 of 13


38
39 Stack To Point of Interest R 60.000 m
40 Flare Height H 41.927 m
41
Calculation are based on API RP 521

Flare Stack Calculation, Erwin A Page 2 of 13


Flare Stack Calculation Sheet
Brzustowski's and Sommer's Approach
Title : Date of Calculation :
HP Flare Calculation ###
Project No : Calculate By :
1131/SKPI-SKPP-2006 Erwin Apriandi

1 Description Symbol Unit


2 Flowrate 75.010 MMscfd
3 88,501.944 m3/hr
4 24.584 m3/s
5 Mass Flow W 90123.000 kg/hr
6 Mol Weigth Mj 24.070
7 Pressure at Flare Tip Pj 124.000 kPa
8 Flowing Temperature Tj 283.900 K
9 Air Temperature T~ 289.000 K
10 Compressibility factor z 1.000
11 Ratio of Specific Heat k 1.210
12 Mach No 0.450
13
14
15 Flare Tip ID dj 0.404 m
16
17
18 Heat of combustion 47140.000 kJ/kg
19 Heat Liberated Q 1180110.617 kW
20 Flame Length L 60.000 m approx
21
Fig 8 & 9
22 Wind velocity U~ 11.800 m/s
23 Sonic Velocity 344.534 m/s
24 Flare Tip velocity Uj 155.040 m/s
25
26 LEL CL 2.100 %v/v
27 LEL Conc Factor 0.229
28 Jet & Wind thrust parameter 26.248
29
Fig C.2 Fig C.3
30 From Fig C.2.B & C.3.B
31 Horizontal distance, from stack to flame centre xc 17.000 m approx
32 Vertical distance, from stack to flame centre yc 14.000 m approx
33
34
35 Fraction Radiated Heat F 0.300
36 1.000

Flare Stack Calculation, Erwin A Page 3 of 13


37 Allowable Radiation K 6.310 kW/m2
38 Safe Distance to Flame Centre D 66.836 m
39
40
41 Stack To Point of Interest R 60.000 m
42 Flare Height H 37.167 m
43
Calculation are based on API RP 521

Flare Stack Calculation, Erwin A Page 4 of 13


Fig 8 & 9

Flare Stack Calculation, Erwin A Page 5 of 13


Flare Stack Calculation, Erwin A Page 6 of 13