Industry Product Catalogue WEB
Industry Product Catalogue WEB
Industry Product Catalogue WEB
100%
Full load tested
VLT drives are factory tested
insuring the highest level of
quality and reliability.
www.danfossdrives.com
50%
Energy saving
We take responsibility for every
element of our products. The
fact that we develop and pro-
duce our own features, hard-
ware, software, power modules,
printed circuit boards and
accessories is your guarantee of
reliable products.
2
Helps you stay green,
clean and efficient
The basic urge for Danfoss VLT One basic technology Throughput modularity
Drives is to enable our millions of versions This is possible due to throughput
customers to have easy Thats why our customers always will modularity in the design. Components
and efficient control of any ask for specific power sizes, features, developed for one drive can be mass
application powered by an AC enclosure classes and fieldbus produced and used in many different
motor. protocols. types of drives and the same
modularity allows for easy and quick
Controlling an application a fan, The VLT concept is to mass produce updates and upgrades of your VLT
pump, compressor, centrifuge, hoist, such highly customized drives drive.
etc. via the power supply provides from a relatively limited number of
two important benefits: components on stock.
Know one and you
Fully automated operation will know them all
Major energy savings Factory built and tested The control panel is such an element.
Having received an order a drive Knowing how to control one drive
specified by the customer our factory with the local control panel, you will
Energy savings builds it and tests it against real motors be able to control all other VLT drives.
Energy savings are tied to the before shipping. Embedded features and different
technology and the fact that plug-in options make the difference
applications need less energy when Factories and competence centres all between the different versions.
idle or operating with partial loads. around the globe, enables Danfoss VLT
Drives to deliver drives that suits your This catalog presents the majority of
VLT drives do the trick and no brand purpose exactly within a few days. our different versions and describes
is more energy efficient than VLT how they are dedicated for specific
drives. industries and applications.
3
Contents
VLT AutomationDrive VLT DriveMotor FCM 300
The VLT AutomationDrive is a single drive concept that The VLT FCM 300 Series is an integrated drive-motor
covers the entire spectrum of drives applications a solution which combines a VLT frequency converter and
PAGE 22
PAGE 6
major benefit in commissioning, operating and main- a high standard quality induction motor in a single
taining the equipment. VLT AutomationDrive comes product. The frequency converter is attached in place of
in a standard version (FC 301) and an advanced high the motor terminal box and it is no higher than the
dynamic version (FC 302) with additional functionalities. standard terminal box nor wider or longer than the
motor.
PAGE 24
PAGE 10
tions, offering advanced application protective features. sions, the HygienicDrive and the Standard version. The
Available with cascade control in fixed speed mode or HygienicDrive is certified for use in clean rooms and the
master/follower mode. pharmaceutical industry. The compact construction of
the OneGearDrive makes it especially suitable for mount-
ing on transport and conveyor systems.
PAGE 28
set-ups and optimises energy efficiency and operation. direct-on-line starting is undesirable. MCD 200 is,
because of its size and functionality, a good alternative
to other reduced voltage starting methods such as star/
delta starters.
VLT Decentral Drive FCD 302 VLT Soft Starter MCD 100
The VLT Decentral Drive FCD 302 is the new generation The VLT Soft Starter is a cost effective and extremely
of the highly successful VLT Decentral FCD 300, based compact soft starter for AC motors from 1.5 - 15 HP. Due
PAGE 18
PAGE 30
on the VLT AutomationDrive FC 302 platform. It to a unique semiconductor design it is a true fit and
combines the key features of both products in a forget product.
completely re-designed enclosure, made for best fit on
direct machine mounting.
PAGE 32
the machine/wall close to the motor or directly onto Drive is the first solution combining an active filter and a
the motor. The decentral design eliminates the need for drive in one package. The VLT Low Harmonic Drive
space-consuming control cabinets and the need for long continuously regulates harmonic suppression according
screened motor cables is significantly reduced. to the load and grid conditions without affecting the
connected motor.
4
VLT 12-Pulse Drives VLT Motion Control Tool
A robust and cost effective harmonic solution for the MCT 10
higher power range. The Danfoss VLT 12-pulse drive For managing drive parameters in systems, the Motion
PAGE 34
PAGE 46
offers reduced harmonics for demanding industry Control Tool MCT 10 is the perfect tool to handle all
applications above 300 HP. The VLT 12-pulse is a high drive-related data.
efficiency variable frequency converter which is built to
the same modular design as the popular 6-pulse VLT
drives.
PAGE 48
PAGE 36
Filters can compensate for individual VLT drives as a harmonics will be an issue in your installation when
compact integrated solution or can be installed as a drives are added. VLT MCT 31 estimates the benefits of
compact stand-alone solution at a point of common cou- adding various harmonic mitigation solutions from the
pling, compensating for multiple loads simultaneously. Danfoss product portfolio and calculates system
Danfoss Active Filters can operate at medium voltage harmonic distortion.
level by means of a step-down transformer.
PAGE 50
PAGE 52
that mitigate high frequency noise in the motor cable the necessary VLT Service facilities are at your
(shielded or unshielded) and reduce bearing currents in disposal, which will minimize downtime and
the motor. increase productivity at your factory.
5
VLT AutomationDrive
Perfect
match for:
Industrial automation
High dynamic applications
Safety installations
The VLT AutomationDrive is a single drive concept that covers an entire range of applications,
which is a major benefit in commissioning, operating and maintaining the equipment.
The modular open-technology Feature Benefit
platform that VLT AutomationDrive Reliable Maximum uptime
is built on makes it exceptionally Ambient temperature 50 C without derating Less need for cooling or oversizing
adaptable and programmable. Its Available in IP 00, 20, 21, 54, 55 Suitable for harsh and wash down areas
and 66 enclosures
configurable, user-friendly interface
Resistant to wear and tear Low lifetime cost
supports local languages and letters. Back-channel cooling for frame D, E and F Prolonged lifetime of electronics
User-friendly Saves commissioning and operating cost
Plug-and-Play technology Easy upgrade and change over
Pluggable options Awarded control panel User-friendly
The drive solution can be adapted to Intuitive VLT interface Saves time
any application due to the flexible Pluggable cage clamp connectors Easy connection
option structure. Numerous options are Exchangeable languages User-friendly
Intelligent
available and can be mounted and
Intelligent warning systems Warning before controlled stop
tested from factory or be plugged in
Smart Logic Control Reduces need for PLC capacity
later for change-over or upgrade. Advanced plug-in features Easy commissioning
Safety cat. 3 (EN 954-1), PL d (ISO 13849-1),
Safe stop Stop cat. 0 (EN 60204-1)
Adapts to the future STO: Safe Torque Off (IEC 61800-5-2) SIL 2 (IEC 61508)
SIL CL 2 (IEC 62061)
The modular concept of VLT Auto-
Intelligent heat management Extends life of the drive
mationDrive makes it highly adaptable
to future features and options. replaced with a blank cover. Settings
Modularity offers the benefit of buying are easily trans- ferred via the LCP from
on a need-to-have basis without losing one drive to another or from a PC to a
future possibilities. drive with the VLT Set-up Software
MCT 10.
6
Options Mains supply (L1, L2, L3)
200 240 V 10%
The following options are available: FC 301: 380 480 V 10%
Supply voltage FC 302: 380 500 V 10%, 525 600 V 10%
525 690 V 10%
Fieldbus options Supply frequency 50/60 Hz
MCA 101 Profibus True Power Factor () 0.92 nominal at rated load
MCA 104 DeviceNet Displacement Power Factor (cos ) near unity (> 0.98)
MCA 105 CanOpen Switching on input supply L1, L2, L3 Maximum 2 times/min.
MCA 120 PROFINET Output data (U, V, W)
MCA 121 Ethernet IP Output voltage 0 100% of supply voltage
MCA 122 Modbus TCP FC 301: 0.2 1000 Hz (1/3 100 HP)
FC 302: 0 1000 Hz (1/3 100 HP)
Output frequency 0 800 Hz (125 to 1600 HP)
I/O and feedback options 0 300 Hz (Flux mode)
MCB 101 General Purpose I/O Switching on output Unlimited
MCB 102 Encoder Ramp times 13600 sec.
MCB 103 Resolver Note: 160% current can be provided for 1 minute.
Higher overload rating is achieved by oversizing the drive.
MCB 105 Relay
MCB 107 24 V input option Digital inputs
for control voltage Programmable digital inputs FC 301: 4 (5) / FC 302: 4 (6)
MCB 113 Extended Relay Card Logic PNP or NPN
Voltage level 0 24 VDC
MCB 114 VLT Sensor Input
Note: One/two digital inputs can be programmed as digital output for FC 301/FC 302.
Analog input
VLT Automation VT Drive PC Analog inputs 2
Software Tools Modes Voltage or current
MCT 10: FC 301: 0 to +10 V
Voltage level
Ideal for commissioning and FC 302: -10 to +10 V (scaleable)
servicing the drive including guided Current level 0/4 to 20 mA (scaleable)
programming of cascade controller, Pulse/encoder inputs
real time clock, smart logic controller Programmable pulse/encoder inputs FC 301: 1 / FC 302: 2
and preventive maintenance. Voltage level 0 24 V DC (PNP positive logic)
MCT 31: Digital output*
Harmonics calculations tool. Programmable digital/pulse outputs FC 301: 1 / FC 302: 2
Voltage level at digital/frequency output 0 24 V
Safety options Analog output*
MCB 108 Safety PLC interface Programmable analog outputs 1
Current range 0/4 20 mA
(DC/DC converter)
MCB 112 ATEX-PTC Thermistor Card Relay outputs*
Programmable relay outputs FC 301: 1 / FC 302: 2
Brake chopper (IGBT) option Cable lengths
Connected to an external brake FC 301: 150 ft / FC 302: 500 ft
(screened/armoured)
resistor, the built-in brake chopper Max. motor cable lengths FC 301: 225 ft / FC 302: 1000 ft
limits the load on the intermediate (unscreened/unarmoured)
circuit in the case the motor acts as a *More analog and digital inputs/outputs can be added by options.
generator.
7
VLT AutomationDrive continued
Current and power ratings
T2 200 240 V T4/T5 380 480/500 V
kW HP Amp. Amp. HO Amp. NO
IP 00
IP 66
IP 66
IP 54
IP 20
IP 20
IP 55
IP 55
IP 21
IP 21
FC 300 HO NO HO NO HO NO 440 V >440 V 440 V >440 V
PK25 0.25 0.33 1.8
PK37 0.37 0.50 2.4 1.3 1.2 1.3 1.2
A1*/A2
A1*/A2
A1*/A2
PK55 0.55 0.75 3.5 1.8 1.6 1.8 1.6
A4/A5
A4/A5
PK75 0.75 1.00 4.6 A2 2.4 2.1 2.4 2.1
A4/A5
A4/A5
P1K1 1.1 1.50 6.6 3 2.7 3 2.7
P1K5 1.5 2.00 7.5 4.1 3.4 4.1 3.4
P2K2 2.2 3.00 10.6 A2 5.6 4.8 5.6 4.8 A2 A2
P3K0 3 4.00 12.5 7.2 6.3 7.2 6.3
A3 A3 A5 A5
P3K7 3.7 5.00 16.7
P4K0 4.0 5.50 10 8.2 10 8.2 A2 A2
P5K5 5.5 7.5 7.5 10 24.2 30.8 13 11 13 11 A5 A5
B3 B1 B1 B1 A3 A3
P7K5 7.5 11 10 15 30.8 46.2 16 14.5 16 14.5
P11K 11 15 15 20 46.2 59.4 B2 B2 B2 24 21 32 27
B4 B3 B1 B1 B1
P15K 15 18 20 25 59.4 74.8 32 27 37.5 34
P18K 18.5 22 25 30 74.8 88 C1 C1 C1 37.5 34 44 40
C3 B2 B2 B2
P22K 22 30 30 40 88 115 44 40 61 52 B4
P30K 30 37 40 50 115 143 61 52 73 65
C4 C2 C2 C2
P37K 37 45 50 60 143 170 73 65 90 80 C1 C1 C1
C3
P45K 45 55 60 75 90 80 106 105
P55K 55 75 75 100 106 105 147 130
C4 C2 C2 C2
P75K 75 90 100 125 147 130 177 160
P90K 90 110 125 150 177 160 212 190
D3 D1 D1
P110 110 132 150 200 212 190 260 240
P132 132 160 200 250 260 240 315 302
P160 160 200 250 300 315 302 395 361 D4 D2 D2
P200 200 250 300 350 395 361 480 443
P250 250 315 350 450 480 443 600 540
P315 315 400 450 550 600 540 658 590
E2 E1 E1
P355 355 450 500 600 658 590 745 678
P400 400 500 550 650 695 678 800 730
P450 450 500 600 650 800 730 880 780
F1/F3
F1/F3
P500 500 560 650 750 880 780 990 890
P560 560 630 750 900 990 890 1120 1050
P630 630 710 900 1000 1120 1050 1260 1160
F2/F4
F2/F4
Dimensions [Inches]
A2 A2 A3 A4 A5 B2 B3 C1 C2 C3 C4 D1 D2 D3 D4 E1 E2 F1 F2 F3 F4
H 7.9 10.5 15.3 16.5 25.5 15.7 26.8 30.3 21.6 26.0 47.6 62.6 41.1 52.2 33.0 32.8 91.5 91.5 91.5 91.5
W 2.9 3.5 5.1 7.9 9.5 6.5 12.1 14.5 12.1 14.5 16.5 16.0 86.5 67.1 61.8 77.2 85.0 85.0
D 8.1 8.1 6.9 7.9 10.2 9.8 12.2 13.2 13.1 14.97 14.7 28.9 28.9 36.5 36.5 36.5 36.5
H+ 14.7 18.7 29.7 37.4
W+ 3.5 5.1 6.5 12.9 15.3
Note: H and W dimensions are with back-plate. H+ and W+ are with IP upgrade kit. D dimensions are without option. A or B for A2 and A3.
8
T6 525 600 V T7 525 690 V
IP 54/55
kW HP Amp. HO Amp. NO Amp. HO Amp. NO
IP 00
IP 66
IP2 0
IP 55
IP 21
IP21
FC 300 HO NO HO NO 550 V >550 V 550 V >550 V 550 V 690 V 550 V 690 V
PK25 0.25 0.33
PK37 0.37 0.50
PK55 0.55 0.75
PK75 0.75 1.00 1.8 1.7
P1K1 1.1 1.50 2.6 2.4
P1K5 1.5 2.00 2.9 2.7 A3 A3 A5 A5
P2K2 2.2 3.00 4.1 3.9
P3K0 3 4.00 5.2 4.9
P3K7 3.7 5.00
P4K0 4.0 5.50 6.4 6.1
P5K5 5.5 7.5 7.5 10 9.5 9 A3 A3 A5 A5
P7K5 7.5 11 10 15 11.5 11
P11K 11 15 15 20 19 18 23 22 14 13 19 18
B3 B1 B1 B1
P15K 15 18 20 25 23 22 28 27 19 18 23 22
B2 B2
P18K 18.5 22 25 30 28 27 36 34 23 22 28 27
B2 B2 B2
P22K 22 30 30 40 36 34 43 41 B4 28 27 36 34
P30K 30 37 40 50 43 41 54 52 36 34 43 41
P37K 37 45 50 60 54 52 65 62 C1 C1 C1 43 41 54 52
C3
P45K 45 55 60 75 65 62 87 83 54 52 65 62 C2 C2
P55K 55 75 75 100 87 83 105 100 65 62 87 83
C4 C2 C2 C2
P75K 75 90 100 125 105 100 137 131 87 83 105 100
P90K 90 110 125 150 113 108 137 131
P110 110 132 150 200 137 131 162 155 D3 D1 D1
P132 132 160 200 250 162 155 201 192
P160 160 200 250 300 201 192 253 242
P200 200 250 300 350 253 242 303 290
D4 D2 D2
P250 250 315 350 450 303 290 360 344
P315 315 355 450 550 360 344 418 400
P355 355 400 500 600 395 380 470 450
E2 E1 E1
P400 400 450 550 650 429 410 523 500
P450 450 500 600 650
P500 500 560 650 750 523 500 596 570
E2 E1 E1
P560 560 630 750 900 596 570 630 630
P630 630 710 900 1000 659 630 763 730
F1/F3
F1/F3
P710 710 800 1000 1200 763 730 899 850
P800 800 1000 1200 1350 889 850 988 945
P900 900 1000 988 945 1108 1060
F2/F4
9
VLT Automation VT Drive
Perfect
match for:
Industrial Pumps
Fans & Blowers
Compressors
Danfoss VLT Drives unequalled experience was used to make the Automation VT Drive the perfect match
for AC motor driven applications in modern water and wastewater systems also for retrofitting.
10
Options High power options
A wide range of integrated options can IEC Emergency stop with
be fitted in the drive: Safety Relay
Safety Stop with Safety Relay
Fieldbus options RFI Filters
MCA 101 Profibus NAMUR terminals
MCA 104 DeviceNet RCD
MCA 105 CanOpen IRM
MCA 120 PROFINET Mains shielding
MCA 121 Ethernet IP Regen terminals
MCA 122 Modbus TCP
Power options
I/O and feedback options We offer a wide range of external
MCB 101 General Purpose I/O power options for use together with
MCB 105 Relay our drive in critical networks or
MCB 107 24 V input option applications:
for control voltage
MCB 114 VLTR Sensor Input VLT Low Harmonic Drive:
Optimum reduction of harmonic
Safety options distortion with built-in active filter.
MCB 108 Safety PLC interface VLT Advanced Harmonic Filter:
(DC/DC converter) For applications where reducing
MCB 112 ATEX-PTC Thermistor Card harmonic distortion is critical.
dV/dt filter: For providing motor
Brake chopper (IGBT) option isolation protection.
Connected to an external brake Sine wave filter (LC filter):
resistor, the built-in brake chopper For noiseless motor.
limits the load on the intermediate
circuit in the case the motor acts as a
generator. FC322 PC software tools
MCT 10:
Power options Ideal for commissioning and
Brake resistors servicing the drive including guided
Sine-Wave Filters programming of cascade controller,
dV/dt Filters real time clock, smart logic controller
Harmonic Filters (AHF) and preventive maintenance.
VLT Energy Box:
24 V DC supply option (MCB 107) Comprehensive energy analysis
Back-up option to keep the control tool. Energy consumption with and
system alive during mains loss. w/o drive can be calculated (drive
payback time). Online function for
Coated PCB available accessing drives energy log.
For harsh environments, according to MCT 31:
levels in IEC61721-3-3, standard 3C2, Harmonics calculations tool.
optional 3C3.
11
VLT Automation VT Drive Specifications
continued Mains supply (L1, L2, L3)
200 240 V 10%,
380 480 V 10%,
Supply voltage 525 600 V 10%,
525 690 V 10%
Supply frequency 50/60 Hz
Displacement Power Factor (cos ) near unity (> 0.98)
True power factor ( 0.9
Switching on input supply L1, L2, L3 1 2 times/min.
Output data (U, V,W)
Output voltage 0 100% of supply
Switching on output Unlimited
Ramp times 0.1 3600 sec.
Output frequency (dependent on power size) 1000 Hz
Note: VLT AQUA Drive can provide 110% current for 1 minute.
Higher overload rating is achieved by oversizing the drive.
Digital inputs
Programmable digital inputs 6*
Logic PNP or NPN
Voltage level 0 24 VDC
* Two of the inputs can be used as digital outputs.
Analog inputs
Number of analog inputs 2
Modes Voltage or current
Voltage level -10 to +10 V (scaleable)
Current level 0/4 to 20 mA (scaleable)
Pulse inputs
Programmable pulse inputs 2
Voltage level 0 24 VDC (PNP positive logic)
Pulse input accuracy (0.1 110 kHz)
* Two of the digital inputs can be used for pulse inputs.
Analog output
Programmable analog outputs 1
Current range at analog output 0/4 20 mA
Relay outputs
Programmable relay outputs 2 (240 VAC, 2 A and 400 VAC, 2 A)
Fieldbus Communication
FC Protocol and Modbus RTU built-in (Optional: Modbus TCP, Profibus, DeviceNet, Ethernet IP)
Ambient temperature
Up to 55 C (50 C without derating)
Dimensions [Inches]
A2 A2 A3 A4 A5 B2 B3 C1 C2 C3 C4 D1 D2 D3 D4 E1 E2 F1 F2 F3 F4
H 7.9 10.5 15.3 16.5 25.5 15.7 26.8 30.3 21.6 26.0 47.6 62.6 41.1 52.2 33.0 32.8 91.5 91.5 91.5 91.5
W 2.9 3.5 5.1 7.9 9.5 6.5 12.1 14.5 12.1 14.5 16.5 16.0 86.5 67.1 61.8 77.2 85.0 85.0
D 8.1 8.1 6.9 7.9 10.2 9.8 12.2 13.2 13.1 14.97 14.7 28.9 28.9 36.5 36.5 36.5 36.5
H+ 14.7 18.7 29.7 37.4
W+ 3.5 5.1 6.5 12.9 15.3
Note: H and W dimensions are with back-plate. H+ and W+ are with IP upgrade kit. D dimensions are without option. A or B for A2 and A3.
12
Current and power ratings
T2 200 240 V T4 380 480 V
T6 525 600 V T7 525 690 V
1 ph 3 ph 1 ph 3 ph
Amp. Amp. A A
IP 54/55
All IP cl.*
440 V
>440 V
440 V
>440 V
550 V
>550 V
690 V
550 V
IP 00
IP 00
IP 66
IP 66
IP 66
IP 66
IP 54
IP 20
IP 20
IP 20
IP 20
IP 55
IP 55
IP 55
IP 55
IP 21
IP 21
IP 21
IP 21
FC 322 kW HP Amp.
PK25 0.25 0.33 1.8
PK37 0.37 0.50 2.4 1.3 1.2
PK55 0.55 0.75 3.5 1.8 1.6
A4/A5
A4/A5
PK75 0.75 1.00 4.6 2.4 2.1 1.8 1.7
A2 A2
P1K1 1.1 1.50 6.6 A3 A5 A5 3 2.7 A2 A2 2.6 2.4
A4/A5
A4/A5
P1K5 1.5 2.00 7.5 4.1 3.4 2.9 2.7 A3 A3 A5 A5
P2K2 2.2 3.00 10.6 5.6 4.8 4.1 3.9
B1 B1
P3K0 3 4.00 12.5 7.2 6.3 5.2 4.9
A3 A3 A5 A5
P3K7 3.7 5.00 16.7
P4K0 4.0 5.50 10 8.2 A2 A2 6.4 6.1
P5K5 5.5 7.50 24.2 B1 B1 13 11 9.5 9 A3 A3 A5 A5
A3 A3 A5 A5
P7K5 7.5 10 30.8 B2 B2 B3 B1 B1 B1 33 30 B1 16 14.5 11.5 11
P11K 11 15 46.2 48 41 B2 24 21 19 18 14 13
P15K 15 20 59.4 C1 C1 B2 B2 B2 32 27 B3 B1 B1 B1 23 22 B3 B1 19 B1 B1 18
B4
P18K 18 25 74.8 37.5 34 C1 37.5 34 28 27 23 22 B2 B2
P22K 22 30 88 C2 C2 C1 C1 C1 44 40 36 34 28 27
C3 B2 B2 B2
P30K 30 40 115 61 52 B4 43 41 B4 B2 B2 B2 36 34
P37K 37 50 143 151 135 C2 73 65 54 52 43 41 C2 C2
C4 C2 C2 C2
P45K 45 60 170 90 80 C1 C1 C1 65 62 54 52
C3 C3 C1 C1 C1
C2 + D1
C2 + D1
P55K 55 75 106 105 87 83 65 62
P75K 75 100 147 130 105 100 87 83
C4 C2 C2 C2 C4 C2 C2 C2
P90K 90 125 177 160 137 131 105 100 D3
P110 110 150 212 190 137 131
D3 D1 D1
P132 132 200 260 240 162 155 D1 D1
P160 160 250 315 302 201 192
P200 200 300 395 361 D4 D2 D2 253 242
P250 250 350 480 443 303 290 D4 D2 D2
P315 315 450 600 540 360 344
P355 355 550 658 590
E2 E1 E1
P400 400 600 745 678 418 400 D4 D2 D2
P450 450 650 800 730 470 450
P500 500 650 880 780 523 500
E2 E1 E1
F1/F3
F1/F3
F1/F3
F1/F3
P800 800 1200 1460 1380 F2/ F4 889 850
P900 900 988 945
P1M0 1000 1720 1530 F2/ F4 1108 1060
F2/F4
13
VLT 2800 Series
Perfect
match for:
Conveyors, centrifuges,
dosing pumps, compressors
Special applications like
cutting machines with
constant speed, and
packaging machines with a
need for high precision
The VLT 2800 series has been developed for the low power market. The drive is extremely compact and
prepared for side-by-side mounting. The concept is modular with a power module and a control module.
14
PC software tools Specifications
MCT 10: Mains supply (L1, L2, L3)
Ideal for commissioning and Supply voltage 200-240 V 10%, 380-480 V 10%
servicing the drive. Supply frequency 50/60 Hz
MCT 31: Displacement Power Factor (cos ) near unity (> 0.98)
Harmonics calculations tool. Switching on input supply L1, L2, L3 12 times/min.
Output data (U, V, W)
Output voltage 0 100% of supply voltage
RFI filter Switching on output Unlimited
The RFI filter ensures that the Ramp times 13600 sec.
frequency converter will not disrupt Closed loop 0132 Hz
other electrical components that are Digital inputs
connected to the mains and might For start/stop, reset, thermistor, etc. 5
cause operating disruption. Logic PNP or NPN
Voltage level 0 24 VDC
By fitting an RFI 1B filter module Analog input
between the mains supply and the No. of analog inputs 2
VLT 2800, the solution complies with Voltage level -10 to +10 V (scaleable)
Current level 0/4 to 20 mA (scaleable)
the EMC norm EN 55011-1B.
Pulse inputs
No. of pulse inputs 2
Voltage level 0 24 V DC (PNP positive logic)
Pulse input accuracy (0.1110 kHz)
Digital output
No. of digital outputs 1
Analog output
Programmable analog outputs 1
Current range 0/4 20 mA
Relay outputs
No. of relay outputs 1
Power Current (Amps)
Fieldbus communication
PN,M Output Input
Mains Type HP RS485
[kW] Amps Amps
2803 0.37 1/2 2.2 5.9 Ambient temperature
2805 0.55 3/4 3.2 8.3 50C
1 x 220-240 V
15
VLT Micro Drive
Perfect
match for:
Industrial Automation
General Purpose Applications
Designed for OEMs
The VLT Micro Drive is a general purpose drive that can control AC motors up to 30 HP.
Its a small robust drive with high efficiency and reliability.
VLT Micro Drive is a full member of Feature
F t Benefit
the VLT family sharing the overall User friendly
quality of design, reliability and user- Minimum commissioning Saves time
friendliness. Mount connect go! Minimum effort minimum time
Copy settings via local control panel Easy programming of multiple drives
Due to high quality components and Intuitive parameter structure Minimal manual reading
genuine VLT solutions, VLT Micro Complies with VLT software Saves commissioning time
Self-protecting features Lean operation
Drive is extremely reliable.
Process PI-controller No need for external controller
Ensure optimal match between drive
Automatic Motor Tuning and motor
RoHS compliant 150% motor torque up to 1 minute Plenty of brake-away and acceleration torque
The VLT Micro Drive is manufactured Flying start (catch a spinning motor) Doesnt trip when started on a spinning
(freewheeling) motor
with respect for the environment, and
Electronic Thermal Relay (ETR) Replaces external motor protection
it complies with the RoHS Directive. Smart Logic Controller Often makes PLC unnecessary
Built-in RFI filter Saves cost and space
Energy saving Less operation cost
Power range Energy efficiency 98% Minimises heat loss
1 phase 200240 V AC ........... 1/4 3 HP Automatic Energy Optimization (AEO) Saves 5-15% energy in HVAC applications
3 phase 200240 V AC ...........1/3 5 HP Reliable Maximum uptime
3 phase 380480 V AC ........ 1/2 30 HP Earth fault protection Protects the drive
Over temperature protection Protects the motor and drive
Short circuit protection Protects the drive
Optimum heat dissipation Longer lifetime
Unique cooling concept with no forced Problem-free operation in harsh
air flow over electronics environments
High quality electronics Low lifetime cost
High quality capacitors Tolerates uneven mains supply
All drives full load tested from factory High reliability
Dust resistant Increased lifetime
RoHS compliant Protects the environment
Designed for WEEE Protects the environment
16
Coated PCB standard Specifications
For harsh environments. Mains supply (L1, L2, L3)
1 x 200 240 V 10%, 3 x 200 240 V 10%
Supply voltage 3 x 380 480 V 10%
Power options Supply frequency 50/60 Hz
Displacement Power Factor (cos ) near unity (> 0.98)
Danfoss VLT Drives offers a range
Switching on input supply L1, L2, L3 12 times/min.
of external power options for use
together with our drives in critical Output data (U, V, W)
Output voltage 0 100% of supply voltage
networks or applications:
Output frequency 0 200 Hz (VVC+ mode), 0 400 Hz (U/f mode)
VLT Advanced Harmonic Filter:
Switching on output Unlimited
For applications where reducing Ramp times 0.05 3600 sec
harmonic distortion is critical.
Digital inputs
Built - In Brake Chopper in 2 HP and
Programmable digital inputs 5
above.
Logic PNP or NPN
Voltage level 0 24 VDC
Pulse inputs
PC software tools
Programmable pulse inputs 1*
MCT 10:
Voltage level 0 24 V DC (PNP positive logic)
Ideal for commissioning and
Pulse input frequency 20 5000 Hz
servicing the drive including * One of the digital inputs can be used for pulse inputs.
guided programming of cascade Analog input
controller, real time clock, smart Analog inputs 2
logic controller and preventive Modes 1 current/1 voltage or current
maintenance. Voltage level 0 10 V (scaleable)
VLT Energy Box: Current level 0/4 to 20 mA (scaleable)
Comprehensive energy analysis Analog output
tool, shows the drive payback time. Programmable analog outputs 1
MCT 31: Current range at analog output 0/4 20 mA
Harmonics calculations tool. Relay outputs
Programmable relay outputs 1 (240 VAC, 2 A)
Approvals
CE, C-tick, UL
Fieldbus communication
FC Protocol, Modbus RTU
Ordering numbers
200 240 VAC 440 480 VAC
Power Output Output
HP 1 ph. 3 ph. 3 ph.
[kW] (Amps) (Amps)
0.18 1/4 1.2 132F 0001
0.25 1/3 1.5 132F 0008
0.37 1/2 2.2 132F 0002 132F 0009 1.1 132F 0017
0.75 1 4.2 132F 0003 132F 0010 2.1 132F 0018
1.5 2 6.8 132F 0005 132F 0012 3.4 132F 0020
2.2 3 9.6 132F 0007 132F 0014 4.8 132F 0022
3.0 4 6.3 132F 0024
3.7 5 15.2 132F 0016 8.2 132F 0026
5.5 7.5 11 132F 0028
M1 M2 M3 M4 M5
7.5 10 14 132F 0030
11.0 15 Micro drives from 2 HP and up 21 132F 0058
Cabinet sizes 15.0 20 have built in brake chopper 27 132F 0059
(mounting flange incl.) 18.5 25 34 132F 0060
[inches] M1 M2 M3 M4 M5 22.0 30 40 132F 0061
Height 5.9 6.92 9.41 11.49 13.18
Width 2.76 2.95 3.54 4.92 6.49
Depth 5.82 6.61 7.63 9.48 9.76 VLT Control panel LCP 11 ............................................................................. Without potentiometer: 132B0100
.25 with Potentiometer VLT Control panel LCP 12 .....................................................................................With potentiometer: 132B0101
17
VLT Decentral Drive FCD 302
Perfect
match for:
Conveyor applications
Installation in wash-down
areas
Widely distributed
applications, with large
number of drives
The VLT Decentral Drive FCD 302 is the newest member of the VLT FCD 300 family, based on the
VLT AutomationDrive FC 302 platform. It combines the key features of both products in a completely
re-designed enclosure, made for best fit on direct machine mounting.
18
Integrated 24 V supply Specifications
24 V DC control supply is provided by Mains supply (L1, L2, L3)
the drive. Separate supply terminals Supply voltage 380 480 V 10%
have been made available for remote Supply frequency 50/60 Hz
l/Os and devices. True Power Factor () 0.92 nominal at rated load
Displacement Power Factor (cos ) (>0.98)
Switching on input supply 2 times/min.
Power looping Output data (U, V, W)
The new FCD 302 facilitates internal Output voltage 0 100% of supply
0 1000 Hz
power looping. 6 Terminals for #10 Output frequency
0 300 Hz (Flux mode)
AWG power cable inside the enclosure Switching on output Unlimited
allows connection of multiple units in Ramp times 0.01 3600 sec.
the same power branch-circuit. Digital inputs
Programmable digital inputs 4 (6)
Logic PNP or NPN
Ethernet switch Voltage level 0 24 V DC
Two RJ-45 ports are available in the Note: One/two digital inputs can be programmed as digital output
drive for easy daisy chaining of Ether- Analog inputs
net communication. Number of analog inputs 2
Modes Voltage or current
Voltage level -10 to +10 V (scaleable)
Current level 0/4 20 mA (scaleable)
Fieldbus options
Pulse/encoder inputs
PROFIBUS DP
Programmable pulse/encoder inputs 2
PROFINET Voltage level 0 24 V DC (PNP positive logic)
Ethernet/IP
Digital output
Programmable digital/pulse outputs 2
Voltage level at digital/frequency output 0 24 V
Application options Analog output
Encoder Programmable analog outputs 1
Resolver Current range 0/4 20 mA
Relay outputs
Programmable relay outputs 2
Hardware options Integrated 24 V supply
Mounting brackets Max. load 600 mA
Service switch
Internal circuit breaker
M12 sensor plugs
24 V DC input for control supply
Brake chopper
Electromechanical brake control and
supply
1.73 12.16
16.33
Dimensions
.98
Small frame size
(0.37 2.2 kW/0.5 3.0 HP) 13.70
14.64
17.69
.51
.98
19
VLT Decentral FCD 300
Perfect
match for:
Material handling in Food
& Beverage and Industry
Installations in wash-
down areas
Widely distributed
applications
The VLT Decentral FCD 300 is a complete frequency converter designed for decentral mounting. It can be
mounted on the machine or a wall near the motor, or directly on the motor itself.
Power range
1/2 - 5 HP - 3 x 380 480 VAC
Enclosure
IP 66/Type 4X (indoor)
Central Vs. Decentral concept Robust cleaning-friendly surface Hot pluggable LCP
20
Specifications
Mains supply (L1, L2, L3)
Supply voltage 3 x 380/400/415/440/480 V 10%
Supply frequency 50/60 Hz
Max. imbalance on supply voltage 2.0% of rated supply voltage
Switching on input supply 2 times/min.
Power Factor (cos ) 0.9 /1.0 at rated load
Output data (U, V, W)
Output voltage 0100% of supply
Overload torque 160% for 60 sec.
Switching on output Unlimited
Ramp times 0.02 - 3600 sec.
Output frequency 0.2 - 132 Hz, 1 - 1000 Hz
Digital inputs
Programmable digital inputs 5
Plug-and-drive Voltage level 024 V DC (PNP positive logic)
The bottom section contains main- Analog inputs
tenance-free Cage Clamp connectors Analog inputs 2 (1 voltage, 1 current)
and looping facilities for power and Voltage level/Current level 0 10 V DC / 0/420 mA (scaleables)
fieldbus cables. Once installed, Pulse inputs
commissioning and upgrading can be Programmable pulse inputs 2 (24 V DC)
performed in no time by plugging in Max. frequency 110 kHz (push-pull) / 5 kHz (open collector)
another control lid. Analog output
Programmable analog output 1
Current range 0/420 mA
Digital output
Programmable digital/frequency output 1
Voltage/frequency level 24 V DC/10 kHz (max.)
Relay output
Programmable relay output 1
Max. terminal load 250 V AC, 2 A, 500 VA
Fieldbus communication
FC Protocol, Modbus RTU, Metasys N2 Built-in
Profibus DP, DeviceNet, AS-interface Optional (integrated)
Externals
Vibration test 1.0 g (IEC 60068)
Max. relative humidity 95 % (IEC 60068-2-3)
Ambient temperature Max. 40C (24 hour average max. 35C)
Flexible installation
Min. ambient temperature in full operation 0C
The FCD 300 series facilitates internal
Min. ambient temperature at reduced perfor-
power line and fieldbus looping. -10C
mance
Terminals for 4 mm2 power cables Approvals CE, UL, C-tick, ATEX*
inside the enclosure allows connec- * Contact Danfoss for details
tion of up to 10+ units.
21
VLT DriveMotor FCM 300
Perfect
match for:
Air Handling Unit fan
wheels
Pumps
Simple conveyors
The VLT FCM 300 Series is an integrated drive-motor solution which combines
a VLT frequency converter and a high standard quality motor in a single product.
22
Specifications
Mains supply (L1, L2, L3)
Supply voltage 3 x 380/400/415/440/460/480V 10%
Supply frequency 50/60 Hz
Power factor (cos ) Max. 0.9/1.0 at rated load
Max. imbalance of supply voltage 2% of rated supply voltage
Switching on supply input Once every 2 minutes
Control Characteristics (frequency converter)
Frequency range 0 132 Hz
Overload torque 160% for 60 sec.
Resolution on output frequency 0.1%
System response time 30 msec. 10 msec.
15 RPM (open loop, CT mode,
Speed accuracy 4-pole motor 150 1500 RPM)
Digital inputs
Control panel Programmable digital inputs 4
A Local Control Panel is available for Voltage level 0 24 V DC (PNP positive logic)
operating, setup and diagnostics. The Analog inputs
LCP can be handheld or mounted in a Analog inputs 2 (1 voltage, 1 current)
panel front (IP65). Voltage/current level 0 10 V DC / 0/4 20 mA (scaleables)
Pulse input
Programmable pulse input 1 (24 V DC)
Max. frequency 70 kHz (push-pull) / 8 kHz (open collector)
Analog/digital output
Programmable analog/digital output 1
Current/voltage range 0/4 20 mA / 24 V DC
Relay output
Programmable relay output 1
Max. terminal load 250 V AC, 2 A, 500 VA
Fieldbus communication
FC Protocol, Modbus RTU Built-in
Profibus DP Optional (integrated)
Externals
Vibration test 1.0 g (IEC 60068)
Max. relative humidity 95% (IEC 60068-2-3)
Ambient temperature Max. 40 C (24 hour average max. 35 C)
Sleep Mode Min. ambient temperature in full operation 0C
In Sleep Mode the motor will stop in a Min. ambient temperature at reduced
no load situation. When the load -10 C
performance
returns, the frequency converter will
restart the motor.
Technical data
Also available: FCM 305 307 311 315 322 330 340 355 375
Forced ventilation Motor output
For constant operation at low speed [HP] 0.75 1.0 1.5 2.0 3.0 4.0 5.0 7.5 10.0
without torque reduction. [kW] 0.55 0.75 1.1 1.5 2.2 3.0 4.0 5.5 7.5
Motor torque
2-pole [Nm] 1) 1.8 2.4 3.5 4.8 7.0 9.5 12.6 17.5 24.0
4-pole [Nm] 2) 3.5 4.8 7.0 9.6 14.0 19.1 25.4 35.0 48.0
Motor drain holes Frame size
For applications where formation of [mm] 80 80 90 90 100 100 112 132 132
condensate water might occur. Input current [A] 380 V
2-pole 1.5 1.8 2.3 3.4 4.5 5.0 8.0 12.0 15.0
4-pole 1.4 1.7 2.5 3.3 4.7 6.4 8.0 11.0 15.5
Sensorless Pump Control Input current [A] 480 V
OEM version 2-pole 1.2 1.4 1.8 2.7 3.6 4.0 6.3 9.5 11.9
Offers precise pressure (head) control 4-pole 1.1 1.3 2.0 2.6 3.7 5.1 6.3 8.7 12.3
without using a pressure transmitter. 1) at 400 V, 3000 RPM, 2) at 400 V, 1500 RPM
23
VLT OneGearDrive
Perfect
match for:
Dry and wet areas
Clean room production areas
The compact design of the VLTe OneGearDrive makes it predestined for use in Material Handling and conveying
systems. The drive has been designed especially for use in the food and beverage industry, although this new
generation of transmission product offers significant benefits in all conveyor drive applications.
24
Product range Speed/ torque characteristics for gear ratios
Power rating ........................................................................2 4 HP i = 31.13; i = 14.13 and i = 8.12 (max 3.0 kW)
Max speed .................................................... 3000 RPM @ 250 Hz
Frequency ................................................................... max. 250 Hz
i = 14,13
Current.............................................................................. max. 7.2 A 250
200
Constants
Torque S1 / [Nm]
Torque........................................................................ kt 1,7 Nm/A 150
50
0
0 40 80 120 160 200 240 280
Speed [rpm]
i = 31,13
400
350
300
Torque S1 / [Nm]
250
VLT OneGearDrive Hygienic 200
The OneGearDrive Hygienic complies with the require- 150
ments for best cleaning and hygienic design with 100
certification according to EHEDG (European Hygienic
50
Engineering & Design Group).
0
0 20 40 60 80 100 120
It is certified as usable for clean rooms and aseptic filling by Speed [rpm]
IPA (Fraunhofer institute) according to the dedicated
Air Cleanliness Classification DIN EN ISO 14644-1.
i = 8,12
The OneGearDrive is designed to be integrated in the plant 160
equipment and to withstand the same cleaning agents and 140
physical cleaning as the rest of the aseptic production
120
equipment.
Torque S1 / [Nm]
100
80
60
40
Danfoss GmbH
OneGearDrive Hygienic
20
TYPE EL - CLASS I
SEPTEMBER 2010
0
0 50 100 150 200 250 300 350 400 450
Speed [rpm]
19.01
2.91 5.78 3.09 7.24
7.28
7.20
.13
4.52
25
VLT Soft Starter MCD 500
Perfect
match for:
Pumps
Conveyors
Fans
Mixers
Compressors
Centrifuges
Mills
Saws, and many more
VLT Soft Starter MCD 500 is a total motor starting solution. Current transformers
measure motor current and provide feedback for controlled motor ramp profiles.
26
Specifications
Mains voltage (L1, L2, L3)
MCD5-xxxx-T5 200 VAC ~ 525 VAC ( 10%)
MCD5-xxxx-T7 380 VAC ~ 690 VAC ( 10%)
380 VAC ~ 600 VAC ( 10%)
MCD5-xxxx-T7 (inside delta connection)
Control voltage (terminals A4, A5, A6)
CV1 (A5, A6) 24 VAC/VDC ( 20%)
AAC Profiles CV2 (A5, A6) 110~120 VAC (+ 10% / - 15%)
CV2 (A4, A6) 220~240 VAC (+ 10% / - 15%)
Mains frequency 50/60 Hz ( 10%)
Rated insulation voltage to earth 600 VAC
Fully featured Soft Starter for Rated impulse withstand voltage 4 kV
motors up to 1100 HP Form designation Bypassed or continuous, semiconductor
Total motor starting solution motor starter form 1
Advanced start, stop and protection Short circuit capability
features Coordination with semiconductor fuses Type 2
Adaptive Acceleration Control Coordination with HRC fuses Type 1
MCD500-0021B to 0215B Prospective current of 65 kA
Inside Delta connection
MCD500-0245C Prospective current of 85 kA
4-line graphical display MCD500-1200C to 1600C Prospective current of 100 kA
Multiple programming setup menus
Electromagnetic capability (compliant with EU Directive 89/336/EEC)
IEC 60947-4-2 Class B and
EMC Emissions (Terminals 13 & 14) Lloyds Marine No. 1 Specification
Optional EMC Immunity IEC 60947-4-2
Modules for serial communication: Outputs
DeviceNet 10A @ 250 VAC resistive, 5A
Relay Outputs
Profibus @ 250 VAC AC15 pf 0.3
Modbus RTU Programmable Outputs
Relay A (13, 14) Normally open
USB
Relay B (21, 22, 24) Changeover
Remote operator kit Relay C (33, 34) Normally open
PC software: Analog Output (07, 08) 0 20 mA or 4 20 mA ( selectable)
WinMaster Maximum load 600 (12 VDC @ 20 mA) (accuracy 5%)
MCT10 24 VDC Output (16, 08) Maximum load 200 mA (accuracy 10%)
Environmental
Protection MCD5-0021B ~ MCD5-0105B IP 20 & NEMA, UL Indoor Type 1
Protection MCD5-0131B ~ MCD5-1600C IP 00, UL Indoor Open Type
Operating temperature -10 C to 60 C, above 40 C with derating
Storage temperature -25 C to + 60 C
Operating Altitude 0 1000 m, above 1000 m with derating
Humidity 5% to 95% Relative Humidity
Pollution degree Pollution Degree 3
Heat Dissipation
During start 4.5 watts per ampere
Dimensions
Current rating [A] Weight [lbs] Height [in] Width [in] Depth [in] Frame size
Remote operation kit 21. 37. 43 and 53 9.3
7.2
68 9.9 11.6 5.9 G1
Start/stop, reset
84, 89 and 105 10.8 8.4
LED for start, run, trip 131, 141, 195 and 215 32.8 17.2 10.8 9.8 G2
Trip codes 245 52.7 18.1 15.4 11 G3
Current display 360, 380 and 428 110.5
27.1 16.9 11.9 G4
Motor temperature display 595, 619, 790 and 927 117.1
4 20 mA output 1200, 1410 and 1600 264.6 33.7 23 14.3 G5
27
VLT Compact Starter MCD 200
Perfect
match for:
Pumps
Fans
Compressors
Mixers
Conveyors
and many more
The VLT Compact Starter MCD 200 from Danfoss includes two families
of soft starters in the power range from 10 - 150 HP.
U I Current U
limit
Ramp Ramp
Ramp up down M Ramp up down M
Initial torque 3~ Initial current
3~
28
Soft Starter for motors Specifications
up to 150 HP Mains supply (l1, L2, L3)
Total motor starting solution Supply voltage 3 X 200 - 480 VAC (T6 model)
Start, stop and protection features Supply frequency 45 66 Hz
Local programming keypad and Control voltage CV1 - 24 VAC / VDC
CV3 - 110 -240 VAC & 380-440 VAC
display
Control inputs
Start, Stop
Control inputs Reset upsh button on the unit
Optional
Relay outputs
Modules for serial communication:
1 x main contactor
DeviceNet Relay outputs 1 x programmable* (Trip or Run)
Profibus Protections, MCD 201
Modbus RTU Phase sequence
USB Supply fault
Shorted SCR
Remote operator kit
PC software Protections, MCD 202
Pump application module Motor thermistor input
Motor temperature thermal model
Phase imbalance
Phase sequence
Excess start time
Supply fault
Shorted SCR
LED indications
Ready/Fault
Indications Run
Ambient operating temperature
Ambient temperature -5 to 60C (above 40C without derating)
Standards approvals
Approvals CE, UL, C-UL, CCC, C-tick, Lloyds
29
VLT Soft Starter MCD 100
Perfect
match for:
Smaller compressors for
example scroll or recipro-
cating compressors in
air-conditioning units
Conveyor systems
Pumps
MCD 100 is a cost effective and extremely compact soft starter for AC motors.
0% Time
Initial Torque up to
85% of nominal torque
30
Timed voltage ramp Specifications
Micro Soft Start Controller for Mains supply (L1, L2, L3)
motors up to 15 HP MCD 100 3 x 208 VAC ~ 600 VAC (+10% / -15%)
Extremely robust SCR design with Supply frequency (at start) 45 Hz 66 Hz
heavy ratings as standard Control circuit (A1, A2)
Unlimited number of starts per hour MCD 100 24 480 VAC/VDC (-15% +10%)
Contactor style design for easy Environmental
selection, installation and Degree of protection MCD 100 IP 20
commissioning Operating temperatures -5 C/+40 C (60 C with de-rating)
Pollution Degree Pollution Degree 3
EMC Emission
Power range Equipment class (EMC) Class A
MCD 100-001 .......................................2 HP Conducted radio frequency emission
MCD 100-007 .....................................10 HP 0.15 MHz 0.5 MHz < 90 dB (V)
MCD 100-011 .....................................15 HP 0.5 MHz 5 MHz < 76 dB (V)
5 MHz 30 MHz 80-60 dB (V)
All sizes are rated for line voltage up to Radiated radio frequency emission
600 V AC. 30 MHz 230 MHz < 30 dB (V/m)
230 MHz 1000 MHz < 37 dB (V/m)
This product has been designed for Class A equipment. Use of the product in domestic environments may
cause radio interference, in wich case the user may be required to employ additional mitigation methods.
EMC Immunity
Electro static discharge 4 kV contact discharge, 8 kV air discharge
Radio-frequency electromagnetic field
0.15 MHz 1000 MHz 140 dB (V)
Rated impulse withstand voltage 4 kV line to earth
(Fast transients 5/50 ns Burst)
Rated insulation voltage 4 kV line to earth, 2 kV line to line
(Surges 1.2/50 s 8/20 s)
Voltage dip and short 100 ms (at 40% nominal voltage)
time interruption
Short Circuit
Rated short-circuit current MCD 100-001 Normal fuses: 25 A gL/gG
SCR I2t rating for semiconductor fuses 72 A2s
Rated short-circuit current MCD 100-007 Normal fuses: 50 A gL/gG
SCR I2t rating for semiconductor fuses 1800 A2s
Rated short-circuit current MCD 100-011 Normal fuses: 80 A gL/gG
SCR I2t rating for semiconductor fuses 6300 A2s
Heat Dissipation
MCD 100-001 Max. 4 watts
MCD 100-007 to MCD 100-011 2 watts/Ampere
Standards Approvals
UL/C-UL UL508
CE IEC 60947-4-2
Dimensions
Power size Rated current Dimensions
Model Approvals
(HP) (Amps) (in) H x W x D
3 A: 5-5:10
2 4.01 x 0.88 x 4.88
(AC 53b)
15 A: 8-3:
MCD100 10 100-3000 4.33 x 1.77 x 5.03 UL, CSA, CE
(AC 53a)
25 A: 6-5:100-480
15 4.33 x 3.54 x 5.03
(AC 53a)
31
VLT Low Harmonic Drive
Optimized
for:
VLT Automation VT Drive
VLT AutomationDrive FC 302
The Danfoss VLT Low Harmonic Drive is the first solution combining an active filter
and a drive in one package.
32
Options Specifications
The following options are available: THiD* at:
RFI filters 40% load < 5,5%
70% load < 3,5%
Disconnect 100% load < 3%
Fuses Efficiency* at:
Mains shielding 40% load > 93%
70% load > 95%
Feedback and I/O options 100% load > 96%
Fieldbus options
True power factor* at:
dV/dt filters 40% load > 98%
Sine wave filters 70% load > 98%
100% load > 98%
Ambient temperature 40 C without derating
Cooling Back-channel air cooling
PC software * Measured at balanced grid without pre-distortion
VLT MCT 10 Setup Software Norms and recommendations Compliance
VLT MCT 10 offers advanced IEEE519 Yes
programming functionality for all IEC61000-3-4 (above 75 A) Yes
Danfoss drive products, greatly
reducing programming and set-up
time.
33
VLT 12-pulse drive
Optimized
for:
VLT Automation VT Drive
VLT AutomationDrive FC 302
Robust and cost effective harmonic solution for the higher power range. The Danfoss VLT 12-pulse drive
offers reduced harmonics for demanding industry applications above 350 HP.
34
Specifications
PC software THiD* at:
VLT MCT 10 Setup Software 40% load 20%
70% load 14%
VLT MCT 10 offers advanced 100% load 12%
programming functionality for all Efficiency* at:
Danfoss drive products, greatly 40% load 95%
reducing programming and set-up 70% load 97%
100% load 98%
time.
True power factor* at:
40% load 91%
VLT MCT 10 Basic (available free of 70% load 95%
100% load 97%
charge on www.danfossdrives.com) Ambient temperature 45 C without derating
allows access to a finite number of Cooling Back-channel air cooling
drives with limited functionality. The * Measured at balanced grid without pre-distortion
advanced edition, offering a higher Norms and recommendations Compliance
level of functionality, is available from IEEE519 Depends on grid and load conditions
your Danfoss sales partner. IEC61000-3-4 (above 75 A) Yes
F10 F12
F8
460 V AC 690 V AC
Normal High Normal High
Overload Overload Overload Overload Dimensions
Frame HxWxD
Power Current Power Current Power Current Power Current IP 21 [in]
[HP] [A] [HP] [A] [kW] [A] [kW] [A]
450 540 350 443 400 450 355 380
F8 89.76 x 31.49 x 23.89
500 590 450 540 500 500 400 410
550 678 500 590 560 570 500 500 F9 w. options 89.76 x 55.11 x 23.89
600 730 550 678 630 630 560 570 cabinet
650 780 600 730 710 730 630 630
F10 89.76 x 62.99 x 23.89
750 890 650 780 800 850 710 730
900 1050 750 890 900 945 800 850 F11 w. options 89.76 x 86.61 x 23.89
1000 1160 900 1050 cabinet
1200 1380 1000 1160 1000 1060 900 945 F12 89.76 x 89.76 x 23.89
1350 1530 1200 1380 1200 1260 1000 1160 F13 w. options 89.76 x 102.36 x 23.89
1400 1415 1200 1260 cabinet
35
VLT Advanced Active Filter AAF 006
Perfect
match for:
Industrial automation
High dynamic applications
Safety installations
36
Options Specifications
The following options are available: THiD* at:
RFI filters 40% load < 7%
70% load < 5,5%
Disconnect 100% load < 5%
Fuses Efficiency* at:
Mains shielding 40% load > 95%
70% load > 98%
100% load > 98%
True power factor* at:
PC software 40% load > 0,98
VLT MCT 10 Setup Software 70% load > 0,98
100% load > 0,98
VLT MCT 10 offers advanced program- Ambient temperature 45 C
ming functionality for all Danfoss drive Cooling Back-channel air cooling
products, greatly reducing program- * Measured at balanced grid without pre-distortion and with VLT drive matching full load demand
ming and set-up time. Norms and recommendations Compliance
IEEE519 Application and load dependent
VLT MCT 10 Basic (available free of
charge from www.danfossdrives.com)
allows access to a finite number of
drives with limited functionality.
The advanced edition, offering a higher
level of functionality, is available from
your Danfoss sales partner.
D14 E1
VLT MCT 31 Harmonics
Calculation Software
With VLT MCT 31, you can determine
whether harmonics will be an issue in
your installation when drives are
added.
37
VLT Advanced Harmonic Filter
Perfect
match for:
Industrial automation
High dynamic applications
Safety installations
38
Options Specifications
The following options are available: AHF 010 AHF 005
IP 21/NEMA 1 kit THiD* at: ~ 7%
40% load ~ 12% ~ 6%
70% load ~ 11% < 5%
100% load < 10%
PC software Efficiency* at 100% load >98.5%
VLT MCT 10 Setup Software True power factor* at:
VLT MCT 10 offers advanced 40% load ~ 81% ~ 80%
70% load ~ 96% ~ 95%
programming functionality for all 100% load > 99% > 98%
Danfoss drive products, greatly Ambient temperature 45 C without derating
reducing programming and set-up Cooling Back-channel air cooling
time. * Measured at balanced grid without pre-distortion
Norms and recommendations Compliance
VLT MCT 10 Basic (available free of IEEE519 AHF 005 Yes
AHF 010 Determined by Grid and load conditions
charge from www.danfossdrives.com)
IEC61000-3-2 (up to 16 A) Yes
allows access to a finite number of IEC61000-3-12 (between 16 and 75 A) Yes
drives with limited functionality. IEC61000-3-4 (above 75 A) Yes
The advanced edition, offering a higher
level of functionality, is available from
your Danfoss sales partner.
Enclosures Dimensions
380415 V 440480 V Dimensions in inches
Enclosure Type Enclosure
50/60 Hz 60 Hz
VLT MCT 31 Harmonics Type A B C
Current [A] Current [A] AHF010 AHF005 (height) (width) (depth)
Calculation Software 10 10 X1 X1 X1 31.07 7.48 8.11
With VLT MCT 31, you can determine 14 14 X1 X1 X2 17.71 9.13 9.76
whether harmonics will be an issue in 22 19 X2 X2 X3 23.38 14.88 9.52
your installation when drives are 29 25 X2 X2 X4 24.56 14.88 13.11
added. 34 31 X3 X3 X5 29.09 16.45 13.11
40 36 X3 X3 X6 30.62 16.45 23.46
VLT MCT 31 estimates the benefits of 55 48 X3 X3 X7 35.78 18.42 17.67
adding various harmonic mitigation 66 60 X4 X4 X8 35.86 18.42 21.37
82 73 X4 X4
solutions from the Danfoss product
96 95 X5 X5
portfolio and calculates system 133 118 X5 X5
harmonic distortion. Furthermore the 171 154 X6 X6
software provides quick indication of 204 183 X6 X6
whether the installation complies with 251 231 X7 X7
the most recognised harmonic norms 304 291 X7 X7
and recommendations. 325 355 X7 X7
381 380 X7 X8
From www.danfoss.com you can 480 436 X7 X8
down-load the free tool VLT Harmonic
Calculation MCT 31 the most up-to-
date version of the calculation
software.
39
VLT Common Mode Filters
Effective
kit to reduce
electromagnetic interference
High-frequency common-mode
(HF-CM) cores are special Feature Benefit
nanocrystalline magnetic cores which Effective reduction of electrical discharges
in the motor bearings
have superior filtering performance High-performance nanocrystalline Reduces bearing wear-out, maintenance
compared to regular ferrite cores. magnetic material costs and down-time
Reduces high-frequency electromagnetic inter-
They act like a common-mode ference from the motor cable
inductor (between phases and Oval shape Easy to install in restricted places such
ground). Scalable solution: longer cables as the VLT enclosure or the motor
handled by stacking more cores terminal box
Installed around the three motor
Easy logistics, fast delivery and
phases (U, V, W), they reduce Only 4 core sizes cover the entire comprehensible product program
VLT power range
high-frequency common-mode Allows the addition to a service tool-kit
currents. As a result, high-frequency Cost-effective alternative to, for example,
sine-wave filters if the only phenomena to
electromagnetic interference from Low investment be mitigated is bearing wear-out through
the motor cable is reduced. However, electrical discharge
the core kit should not be used as the
sole mitigation measure, and even
when the cores are used, the EMC Ideal for retrofitting A flexible solution
installation rules shall be followed. Bearing current problems are most The cores can be combined with
often discovered after commissioning. other output filters, and especially in
Therefore, the cores have an oval shape combination with dV/dt filters they
Prevent motor which makes them ideal for retrofitting offer a low cost solution for protection
bearing currents and for installation in restricted places. of both motor bearings and insulation.
The most important function is to
reduce high-frequency currents Only 4 variants cover the entire VLT
associated with electrical dis- product range making it possible to Product range
charges in the motor currents. carry these valuable aids in a service Available for all power sizes
These discharges contribute to tool kit. from 1/4 1900 HP
the premature wear-out and failure 4 core sizes cover the entire
of motor bearings. By reducing or VLT power range
even eliminating discharges, the
wear-out of the bearings is reduced
and the lifetime extended. Thus,
maintenance and down-time costs
are lowered.
40
HF-CM selector Cable length A and B frame C frame D frame E and F frame
[inches] T5 T7 T5 T7 T5 T7 T5 T7
The cores can be installed at the
150 2 4 2 2 2 4 2 2
frequency converters output terminals 350 4 4 2 4 4 4 2 4
(U, V, W) or in the motor terminal box. 500 4 6 4 4 4 4 4 4
When installed at the frequency 1000* 4 6 4 4 4 6 4 4
converters terminals, the HF-CM kit * Longer cable lengths are easily handled by stacking more HF-CM cores.
reduces bearing stress and high-fre-
quency electromagnetic interference
from the motor cable. The number of
cores depends on motor cable length
and frequency converter voltage. A
selection table is shown to the right.
W
w
d
H h
Installation
41
VLT Power Option Sine-wave Filter
Perfect
match for:
Applications with older
motors
Aggressive environments
Applications with
frequent braking
690 V applications with
general purpose motors
Motor cable length above
150 m (500 feet)
Sine-wave output filters are low-pass filters that suppress the switching frequency component from
the drive and smooth out the phase-to-phase output voltage of the drive to become sinusoidal.
This reduces the motor insulation stress and bearing currents.
By supplying the motor with a Eliminates acoustic noise in motor Noiseless motor operation
Reduces high frequent losses in motor Prolongs service interval of motor
sinusoidal voltage waveform, the
switching acoustic noise from the
motor is also eliminated. Quality and Design Range
All filters are designed and tested for 3 x 200 500 V, 2.5 800 A
Thermal losses and operation with the VLT Automation- 3 x 525 690 V, 13 660 A
bearing currents Drive FC 302, VLT AQUA Drive FC 202,
The sinusoidal voltage supply to the and the VLT HVAC Drive FC 102. They
motor reduces hysteresis thermal are rated for the nominal switching Enclosures
losses in the motor. Since the motor frequency of the VLT FC series and IP 00 and IP 20 wall-mounted
insulation lifetime is dependent on therefore no derating of the drive is enclosure up to 75 A (500 V)/
the motor temperature, the sine-wave needed. 13 A (690 V)
filter prolongs the lifetime of the IP 23 floor-standing enclosure from
motor. The enclosure is designed to match the 115 A (500 V)/28 A (690 V)
look and quality of the VLT FC series
The sinusoidal motor terminal voltage drives.
from the sine-wave filter furthermore Mounting
has the advantage of suppressing any Side by side mount with the drive
bearing currents in the motor. This Advantages up to 75 A (500 V)
reduces the risk of flashover in the Compatible with all control princi-
motor bearings and thereby also ples including flux and VVC+
contributes to extended motor Parallel filter installation is possible
lifetime and increased service for applications in the high power
intervals. range
42
Specifications
3 x 200 500 V and
Voltage rating 3 x 525 690 V
2.5 800A
Nominal current IN @ 50 Hz for higher power modules can be paralleled
0 60 Hz without derating
Motor frequency 100/120 Hz (up to 10 A) with derating
Ambient temperature -25 to 45C without derating
fmin 1,5 kHz 5 kHz
Min. switching frequency
depending on filter type
Max. switching frequency fmax 8 kHz
Overload capacity 160% for 60 sec every 10 min.
Enclosure degree IP 00/IP 20/IP 23 (ref. page 1)
Approvals CE, UL508
43
VLT Power Option dV/dt Filter
Perfect
match for:
Applications with
short motor cables
(up to 150 m (500 ft))
Applications with older
motors
Aggressive environments
Applications with
frequent braking
dV/dt filters reduce the dV/dt values on the motor terminal phase-to-phase voltage
an issue that is important for short motor cables.
dV/dt filters are differential-mode Feature Benefit
filters which reduce motor terminal Reduces dV/dt stresses Increases motor service interval
phase-to-phase peak voltages spikes Lowers the magnetic interference propagation Trouble-free operation
and reduce the rise time to a level on surrounding cables and equipment
Low voltage drop makes dV/dt filters the ideal
that lowers the stress on the solution for highly dynamic applications with flux Small size and cost compared
to sine-wave filters
insulation of motor windings. vector regulation
44
Specifications
0 60 Hz without derating
Motor frequency Max. 100 Hz (with derating)
1.2
Upeak [V]
0
0 0.5 1 1.5 2.0 2.5 3
tr [us]
The dV/dt value decreases with the motor cable length whereas the peak voltage increases. Therefore it is
recommended to use sine-wave filters in installations with motor cable lengths above 150 m (500 ft).
45
VLT Motion Control Tool MCT 10
Perfect
tool for:
Commissioning
Servicing
Programming
The VLT Motion Control Tool, MCT 10, is ideal for commissioning and servicing the drive including guided
programming of cascade controller, real-time clock, smart logic controller and preventive maintenance.
46
Fieldbusses
ProfiBus DP-V1
RS485
USB
Ethernet-TSC
Profibus Profibus
DP V1 DP V1 MCT 10 via Siemens Softnet
Internet download
http://www.danfoss.com/drives
#1 #2 #3 ...#50 #126
System requirements #1 #2 #3 ...#50
MS Windows NT 4.0, 2000,
XP, Vista or 7
Pentium III 350 MHz or better
512 MB RAM or better
200 MB free hard disk space
FC 51
CD-ROM drive
MCT 10 via RS485 MCT 10 via USB
VGA or XGA graphic adapter
47
VLT MCT 31
Harmonics Calculation Software
Perfect
tool for:
Application specific
simulations
Various Power Supply
sources
Norm compliance
indication
Project Documentation
With VLT MCT 31, you can determine whether harmonics will be an issue in your installation when drives are
added. VLT MCT 31 estimates the benefits of adding various harmonic mitigation solutions from the Danfoss
product portfolio and calculates system harmonic distortion.
Save money and reduce Feature Benefit
running costs Explore-like view Easy to use
On the basis that it is better to avoid a Simple simulation model with less parameters Easy to use and fast simulation saves time
problem rather than cure one after it Configurable for various Power supply sources Matching all customer needs
happens, it is preferable to calculate One tool supporting all Danfoss harmonic Matching all customer needs
the effect of installing non-linear loads mitigation solutions
before doing so, to estimate the degree Configurable Norm compliance indication Save time
User configurable Report gation solutions Project documentation
of harmonic distortion that may result.
Trying to achieve this on a spreadsheet Saves time and money. Prevent problems
Simulate the setup before installation appear later
basis can be time consuming and
inaccurate. Calculate the harmonic The Windows-like interface of the
disturbance MCT 31 tool makes possible intuitive
To help, Danfoss offers free to The MCT 31 tool can easily be used operation of the software. It is built
download, the VLT Harmonic to evaluate the expected grid quality with a focus on user-friendliness
Calculation Tool MCT 31, a simple and includes a range of passive and and the complexity is limited to
to use and fast software tool for active counter-measures which can be system parameters that are normally
calculating the harmonic disruption selected to ease system stress. accessible.
from your existing or intended drives
installation. The power quality impact of The Danfoss VLT frequency converter
electronic devices can be estimated and mitigation equipment data is
A fast estimate is vital as, in this case, in the frequency range up to 2.5 kHz, already pre-loaded, allowing fast data
more is not better, simply more costly, depending on the system configuration entry.
so the MCT 31 can help save money and standard limits.
when selecting harmonic mitigation Your local Danfoss consultant will be
solutions. The analysis includes indication of very happy to provide all the assistance
Simply over-specifying a harmonic compliance with various standards and you need to evaluate your power
mitigation solution will lead to recommendations. quality and advice in the selection
unnecessary initial cost escalation and of the correct mitigation for your
increased running expenses. circumstances.
48
Internet download
http://www.danfoss.com/drives
System requirements
MS WindowsR NT 4.0, 2000, XP, Vista
or 7
Pentium III 350 MHz or better
512 MB RAM or better
200 MB free hard disk space
CD-ROM drive
VGA or XGA graphic adapter
49
VLT Energy Box
Perfect
tool for:
Designing HVAC installations
Obtaining energy savings
Calculating pay-back time
With VLT Energy Box software you can both theoretically in project face estimate and afterwards physically
validate your real energy savings and reductions in your carbon footprint from your desk.
With VLT Energy Box software you The software allows you to upload
can both theoretically in project face real trend and energy data, to present
estimate and afterwards physically multiple systems in one report and to
validate your real energy savings and calculate energy consumption for cool-
reductions in your carbon footprint ing towers.
also from your desk.
The VLT Energy Box communicates
with the drives through the USB/ Complete financial analysis
RS485 protocol and can read all data VLT Energy Box provides a complete
about duty cycles and energy financial analysis including:
consumptions.
Initial cost for the drive system and
Data about duty cycles and energy the alternative system
consumptions can be requested Installation and hardware costs
remotely from the VLT HVAC Drive, Annual maintenance costs and any
making it easy to monitor your energy utility company incentives for installa-
savings and return on investment. tion of energy conservation products
Monitoring via fieldbus often makes Payback time and accumulated
energy meters omissible. savings are calculated
50
No nonsense
Since VLT Energy Box both estimates
and afterwards measures the real
energy savings, it is a very trustworthy
means for calculating projects involv-
ing many fans, pumps and cooling
towers. You can simply install a single
VLT HVAC Drive and check the actual
savings to exactly calculate the
benefits from installing VLT HVAC
Drives on the other applications.
51
Service and support
VLT DrivePro
24 hours
on a budget.
DrivePro-SC Service Contract ensures
long-term service coverage beyond DrivePro EnLease provides end
7 days a week the warranty period for drives up to 10 customers with alternative financing for
years old. drives and services.
52
DESIGN
START-UP
PLANNING
MAINTENANCE
TECHNICAL
SUPPORT
DISPOSAL
COVERAGE
53
Danfoss DriveProtection
provides the solution
Emergency response expense threatens your budget.
$3,500
avarage savings
Compared to the cost of
repairing or replacing a
mid-sized drive
60%
downtime reduction
Typically achieved with
factory-direct support
54
Configure your VLT drive
The Drive Configurator gives you the possibility to configure (select) the right drive for your purpose
You dont have to consider if the combinations are valid, while the configurator only gives you valid selections.
Drive Configurator
The Danfoss Drive Configurator is an
advanced but easy-to-use tool to
configure the Danfoss VLT frequency
converter that exactly matches your
requirements.
55
What VLT is all about
Danfoss VLT Drives is the world leader among dedicated drives providers
and still gaining market share.
Danfoss VLT Drives, 4401 N. Bell School Rd., Loves Park, IL 61111, Tel. +1 (815) 639-8600 (main),
Tel. +1 (800) 432-6367 (24 Hour Service for Drives), Fax +1 (815) 639-8000, www.danfossdrives.com, Email: [email protected]
DKDD.PB.101.E1.22 VLT is a trademark of Danfoss A/S Copyright 2011 by Danfoss PE-MMSC 2011.08 177R0390