0% found this document useful (0 votes)
260 views33 pages

MC Rap1

This document is a monitoring channels report for a ship called DIANA owned by Norden. It lists over 100 monitoring channels for the ship's equipment, including parameters like module errors, pressure and temperature readings, and alarm statuses. Each channel is identified by ID number, name, unit of measurement, alarm group, priority level and other technical details.

Uploaded by

nitin9860
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
260 views33 pages

MC Rap1

This document is a monitoring channels report for a ship called DIANA owned by Norden. It lists over 100 monitoring channels for the ship's equipment, including parameters like module errors, pressure and temperature readings, and alarm statuses. Each channel is identified by ID number, name, unit of measurement, alarm group, priority level and other technical details.

Uploaded by

nitin9860
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 33

Lyngso Marine A/S

UMS/UCS 2100
Monitoring Channels Report

Yard/No.: GSI/NB02130010
Ship Name: DIANA
Owner: Norden
Version: 1.02
Print Date: 2005-6-11 15:23:21
Project Manager: CSN

Sorted After: ID
Filter: All Records
Monitoring Channels Report Page
Limit Related Parameters 2 / 33
ID Name Unit
Delay
Type Yard ID Scaling Disp Range Alm Grp Mess. Text Prio On Off Limit Suppression Rev.
01C1AI01 MODULE 01C1AI01 (AEM402) ERROR - - alarm 1 0 0 1.01
Computed - 99
01C1AI02 MODULE 01C1AI02 (MXM402) ERROR - - alarm 1 0 0 1.01
Computed - 99
01C1AI03 MODULE 01C1AI03 (MXM402) ERROR - - alarm 1 0 0 1.01
Computed - 99
01C1AI04 MODULE 01C1AI04 (MXM402) ERROR - - alarm 1 0 0 1.01
Computed - 99
01C1C001 MODULE 01C1C001 (DSN) ERROR - - alarm 1 0 0 1.01
Computed - 99
01C1C002 MODULE 01C1C002 (SIO) ERROR - - alarm 1 0 0 1.01
Computed - 99
01C1M101 MODULE 01C1M101 (DEM401) ERROR - - alarm 1 0 0 1.01
Computed - 99
01C1M102 MODULE 01C1M102 (DEM401) ERROR - - alarm 1 0 0 1.01
Computed - 99
01C1M103 MODULE 01C1M103 (DEM401) ERROR - - alarm 1 0 0 1.01
Computed - 99
01C1M104 MODULE 01C1M104 (DEM401) ERROR - - alarm 1 0 0 1.01
Computed - 99
01C1M201 MODULE 01C1M201 (REM401) ERROR - - alarm 1 0 0 1.01
Computed - 99
02C1AI01 MODULE 02C1AI01 (AEM402) ERROR - - alarm 1 0 0 1.01
Computed - 99
02C1AI02 MODULE 02C1AI02 (MXM402) ERROR - - alarm 1 0 0 1.01
Computed - 99
02C1AI03 MODULE 02C1AI03 (MXM402) ERROR - - alarm 1 0 0 1.01
Computed - 99
02C1AI04 MODULE 02C1AI04 (MXM402) ERROR - - alarm 1 0 0 1.01
Computed - 99
02C1C001 MODULE 02C1C001 (DSN) ERROR - - alarm 1 0 0 1.01
Computed - 99
02C1C002 MODULE 02C1C002 (SIO) ERROR - - alarm 1 0 0 1.01
Computed - 99

Lyngso Marine A/S 651299 Printed: 2005-6-11


Monitoring Channels Report Page
Limit Related Parameters 3 / 33
ID Name Unit
Delay
Type Yard ID Scaling Disp Range Alm Grp Mess. Text Prio On Off Limit Suppression Rev.
02C1C003 MODULE 02C1C003 (SIO) ERROR - - alarm 1 0 0 1.02
Computed - 99
02C1M101 MODULE 02C1M101 (DEM401) ERROR - - alarm 1 0 0 1.01
Computed - 99
02C1M102 MODULE 02C1M102 (DEM401) ERROR - - alarm 1 0 0 1.01
Computed - 99
02C1M103 MODULE 02C1M103 (DEM401) ERROR - - alarm 1 0 0 1.01
Computed - 99
02C1M104 MODULE 02C1M104 (REM401) ERROR - - alarm 1 0 0 1.01
Computed - 99
1100 NO.1 A/E START FAIL 3 20 alarm 1 2 1 1.01
DI NC - -
1101 NO.1 A/E STARTING AIR INL-PL. 3 20 alarm 1 2 1 1.01
DI NC - -
1102 NO.1 A/E F.O.LEAKAGE TK.LH. 3 20 alarm 1 2 1 1.01
DI NC - -
1103 NO.1 A/E L.O.FILT.DIFF P.HDP 3 20 alarm 1 2 1 1.01
DI NC - -
1104 NO.1 A/E L.O.SUMP TK.LEVEL LL 3 20 alarm 1 2 1 1.01
DI NC - -
1105 NO.1 A/E L.O.INL-PRESS.PL bar 0.0 3 20 low pres 1 5 1 4.0 1110 1.02
AI 0_10 10.0 - - low low 1 5 1 3.5 1110
1106 NO.1 A/E C.F.W.INL-PRESS.PL bar 0.0 3 20 low pres 1 2 1 0.8 1110 1.02
AI 0_6 6.0 - -
1107 NO.1 A/E L.O.INL-TEMP TH ?C -50.0 3 20 high temp 1 2 1 75.0 1.01
AI PT100_2 200.0 - -
1108 NO.1 A/E C.F.W OUTLET TEMP TH ?C -50.0 3 20 high temp 1 2 1 90.0 1.01
AI PT100_2 200.0 - -
1109 NO.1 A/E SHUT DOWN AL 3 20 alarm 1 2 1 1.01
DI NC - -
1110 NO.1 A/E STOP(ALARM BL SIGNAL) - 20 alarm 4 0 1 1.02
DI NC - -
1111 NO.1 A/E TACHO.& PWR FAIL AL 3 20 alarm 1 2 1 1.01
DI NC - -

Lyngso Marine A/S 651299 Printed: 2005-6-11


Monitoring Channels Report Page
Limit Related Parameters 4 / 33
ID Name Unit
Delay
Type Yard ID Scaling Disp Range Alm Grp Mess. Text Prio On Off Limit Suppression Rev.
1112 NO.1 A/E JET SYS.FAIL & OVERL 3 20 alarm 1 2 1 1.01
DI NC - -
1113 NO.1 A/E PRE LUB OIL LEVEL LL 3 20 alarm 1 2 1 1.01
DI NC - -
1114 NO.1 D/G EXH.GAS INL-T/C TH ?C 0.0 3 20 high temp 1 2 1 550.0 1.01
AI 0_600D 600.0 - -
1115 NO.1 D/G COOLING AIR TEMP TH ?C -50.0 3 20 high temp 1 2 1 105.0 1.02
AI PT100_2 200.0 - -
1116 NO.1 D/G AIR COOL.W.LEAK 3 20 alarm 1 2 1 1.01
DI NC - -
1117 NO.1 D/G STATOR WIND(U)HT ?C -50.0 3 20 high temp 1 2 1 140.0 1.02
AI PT100_2 200.0 - -
1118 NO.1 D/G STATOR WIND(V)HT ?C -50.0 3 20 high temp 1 2 1 140.0 1.01
AI PT100_2 200.0 - -
1119 NO.1 D/G STATOR WIND(W)HT ?C -50.0 3 20 high temp 1 2 1 140.0 1.01
AI PT100_2 200.0 - -
1120 NO.1 D/G ACB TRIP 3 20 alarm 1 2 1 1.01
DI NC - -
1121 NO.1 D/G ACB NON CLOSE 3 20 alarm 1 2 1 1.01
DI NC - -
1129 NO.2 A/E START FAIL 3 21 alarm 1 2 1 1.01
DI NC - -
1130 NO.2 A/E STARTING AIR INL-PL. 3 21 alarm 1 2 1 1.01
DI NC - -
1131 NO.2 A/E F.O.LEAKAGE TK.LH. 3 21 alarm 1 2 1 1.01
DI NC - -
1132 NO.2 A/E L.O.FILTER HDP 3 21 alarm 1 2 1 1.01
DI NC - -
1133 NO.2 A/E L.O.SUMP TK.LEVEL LL 3 21 alarm 1 2 1 1.01
DI NC - -
1134 NO.2 A/E L.O.INL-PRESS.PL bar 0.0 3 21 low pres 1 5 1 4.0 1139 1.02
AI 0_10 10.0 - - low low 1 5 1 3.5 1139
1135 NO.2 A/E C.F.W.INL-PRESS.PL bar 0.0 3 21 low pres 1 2 1 0.8 1139 1.02
AI 0_6 6.0 - -

Lyngso Marine A/S 651299 Printed: 2005-6-11


Monitoring Channels Report Page
Limit Related Parameters 5 / 33
ID Name Unit
Delay
Type Yard ID Scaling Disp Range Alm Grp Mess. Text Prio On Off Limit Suppression Rev.
1136 NO.2 A/E L.O.INL-TEMP TH ?C -50.0 3 21 high temp 1 2 1 75.0 1.01
AI PT100_2 200.0 - -
1137 NO.2 A/E C.F.W OUTLET TEMP TH ?C -50.0 3 21 high temp 1 2 1 90.0 1.01
AI PT100_2 200.0 - -
1138 NO.2 A/E SHUT DOWN AL 3 21 alarm 1 2 1 1.01
DI NC - -
1139 NO.2 A/E STOP(ALARM BL.SIGNAL) - 21 alarm 4 0 1 1.02
DI NC - -
1140 NO.2 A/E TACHO.& PWR FAIL AL 3 21 alarm 1 2 1 1.01
DI NC - -
1141 NO.2 A/E JET SYS.FAIL & OVERL 3 21 alarm 1 2 1 1.01
DI NC - -
1142 NO.2 A/E PRE LUB OIL LEVEL LL 3 21 alarm 1 2 1 1.01
DI NC - -
1143 NO.2 D/G EXH.GAS INL-T/C TH ?C 0.0 3 21 high temp 1 2 1 550.0 1.01
AI 0_600D 600.0 - -
1144 NO.2 D/G COOLING AIR TEMP TH ?C -50.0 3 21 high temp 1 2 1 105.0 1.02
AI PT100_2 200.0 - -
1145 NO.2 D/G AIR COOL.W.LEAK 3 21 alarm 1 2 1 1.01
DI NC - -
1146 NO.2 D/G STATOR WIND.(U)HT ?C -50.0 3 21 high temp 1 2 1 140.0 1.01
AI PT100_2 200.0 - -
1147 NO.2 D/G STATOR WIND.(V)HT ?C -50.0 3 21 high temp 1 2 1 140.0 1.01
AI PT100_2 200.0 - -
1148 NO.2 D/G STATOR WIND.(W)HT ?C -50.0 3 21 high temp 1 2 1 140.0 1.01
AI PT100_2 200.0 - -
1149 NO.2 D/G ACB TRIP 3 21 alarm 1 2 1 1.01
DI NC - -
1150 NO.2 D/G ACB NON CLOSE 3 21 alarm 1 2 1 1.01
DI NC - -
1159 NO.3 A/E STAR FAIL 3 22 alarm 1 2 1 1.01
DI NC - -
1160 NO.3 A/E STARTING AIR INL-PL. 3 22 alarm 1 2 1 1.01
DI NC - -

Lyngso Marine A/S 651299 Printed: 2005-6-11


Monitoring Channels Report Page
Limit Related Parameters 6 / 33
ID Name Unit
Delay
Type Yard ID Scaling Disp Range Alm Grp Mess. Text Prio On Off Limit Suppression Rev.
1161 NO.3 A/E F.O.LEAKAGE TK.LH. 3 22 alarm 1 2 1 1.01
DI NC - -
1162 NO.3 A/E L.O.FILT.DIFF HDP 3 22 alarm 1 2 1 1.01
DI NC - -
1163 NO.3 A/E L.O.SUMP TK.LEVEL LL 3 22 alarm 1 2 1 1.01
DI NC - -
1164 NO.3 A/E L.O.INL-PRESS.PL bar 0.0 3 22 low pres 1 5 1 4.0 1169 1.02
AI 0_10 10.0 - - low low 1 5 1 3.5 1169
1165 NO.3 A/E C.F.W.INL-PRESS.PL bar 0.0 3 22 low pres 1 2 1 0.8 1169 1.02
AI 0_6 6.0 - -
1166 NO.3 A/E L.O.INL-TEMP TH ?C -50.0 3 22 high temp 1 2 1 75.0 1.02
AI PT100_2 200.0 - -
1167 NO.3 A/E C.F.W OUTLET TEMP TH ?C -50.0 3 22 high temp 1 2 1 90.0 1.01
AI PT100_2 200.0 - -
1168 NO.3 A/E SHUT DOWN AL 3 22 alarm 1 2 1 1.01
DI NC - -
1169 NO.3 A/E STOP(ALM BL.SIGNAL) - 22 alarm 4 0 1 1.02
DI NC - -
1170 NO.3 A/E TACHO.& PWR FAIL AL 3 22 alarm 1 2 1 1.01
DI NC - -
1171 NO.3 A/E JET SYS.FAIL & OVERL 3 22 alarm 1 2 1 1.01
DI NC - -
1172 NO.3 A/E PRE LUB OIL LEVEL LL 3 22 alarm 1 2 1 1.01
DI NC - -
1173 NO.3 D/G EXH.GAS INL-T/C TH ?C 0.0 3 22 high temp 1 2 1 550.0 1.01
AI 0_600D 600.0 - -
1174 NO.3 D/G COOLING AIR TEMP TH ?C -50.0 3 22 high temp 1 2 1 105.0 1.02
AI PT100_2 200.0 - -
1175 NO.3 D/G AIR COOL.WATER LEAK 3 22 alarm 1 2 1 1.01
DI NC - -
1176 NO.3 D/G STATOR WIND.(U)HT ?C -50.0 3 22 high temp 1 2 1 140.0 1.01
AI PT100_2 200.0 - -
1177 NO.3 D/G STATOR WIND.(V)HT ?C -50.0 3 22 high temp 1 2 1 140.0 1.01
AI PT100_2 200.0 - -

Lyngso Marine A/S 651299 Printed: 2005-6-11


Monitoring Channels Report Page
Limit Related Parameters 7 / 33
ID Name Unit
Delay
Type Yard ID Scaling Disp Range Alm Grp Mess. Text Prio On Off Limit Suppression Rev.
1178 NO.3 D/G STATOR WIND.(W)HT ?C -50.0 3 22 high temp 1 2 1 140.0 1.01
AI PT100_2 200.0 - -
1179 NO.3 D/G ACB TRIP AL 3 22 alarm 1 2 1 1.01
DI NC - -
1180 NO.3 D/G ACB NON CLOSE AL 3 22 alarm 1 2 1 1.01
DI NC - -
1181 NO.1 A/E EXH GAS TEMP OUT CYL1 ?C 0.0 3 20 high temp 1 2 2 430.0 1.02
AI 0_600D 600.0 - -
1181A NO.1 A/E CLY1 EXH GAS TEMP DEV ?C -100.0 3 20 low temp 1 2 2 -50.0 1.02
Computed 100.0 - - high temp 1 2 2 50.0
1181AV NO.1 AE CYL. EXH. GAS.TEMP.AV ?C 0.0 3 20 high temp 1 1 1 430.0 1.01
Computed 600.0 - -
1182 NO.1 A/E EXH GAS TEMP OUT CYL2 ?C 0.0 3 20 high temp 1 2 2 430.0 1.01
AI 0_600D 600.0 - -
1182A NO.1 A/E CLY2 EXH GAS TEMP DEV ?C -100.0 3 20 low temp 1 2 2 -50.0 1.02
Computed 100.0 - - high temp 1 2 2 50.0
1183 NO.1 A/E EXH GAS TEMP OUT CYL3 ?C 0.0 3 20 high temp 1 2 2 430.0 1.01
AI 0_600D 600.0 - -
1183A NO.1 A/E CLY3 EXH GAS TEMP DEV ?C -100.0 3 20 low temp 1 2 2 -50.0 1.02
Computed 100.0 - - high temp 1 2 2 50.0
1184 NO.1 A/E EXH GAS TEMP OUT CYL4 ?C 0.0 3 20 high temp 1 2 2 430.0 1.01
AI 0_600D 600.0 - -
1184A NO.1 A/E CLY4 EXH GAS TEMP DEV ?C -100.0 3 20 low temp 1 2 2 -50.0 1.02
Computed 100.0 - - high temp 1 2 2 50.0
1185 NO.1 A/E EXH GAS TEMP OUT CYL5 ?C 0.0 3 20 high temp 1 2 2 430.0 1.01
AI 0_600D 600.0 - -
1185A NO.1 A/E CLY5 EXH GAS TEMP DEV ?C -100.0 3 20 low temp 1 2 2 -50.0 1.02
Computed 100.0 - - high temp 1 2 2 50.0
1186 NO.1 A/E EXH GAS TEMP OUT CYL6 ?C 0.0 3 20 high temp 1 2 2 430.0 1.01
AI 0_600D 600.0 - -
1186A NO.1 A/E CLY6 EXH GAS TEMP DEV ?C -100.0 3 20 low temp 1 2 2 -50.0 1.02
Computed 100.0 - - high temp 1 2 2 50.0
1187 NO.2 A/E EXH GAS TEMP OUT CYL1 ?C 0.0 3 21 high temp 1 2 2 430.0 1.01
AI 0_600D 600.0 - -

Lyngso Marine A/S 651299 Printed: 2005-6-11


Monitoring Channels Report Page
Limit Related Parameters 8 / 33
ID Name Unit
Delay
Type Yard ID Scaling Disp Range Alm Grp Mess. Text Prio On Off Limit Suppression Rev.
1187A NO.2 A/E CLY1 EXH GAS TEMP DEV ?C -100.0 3 21 low temp 1 2 2 -50.0 1.02
Computed 100.0 - - high temp 1 2 2 50.0
1187AV NO.2 AE CYL. EXH. GAS.TEMP.AV ?C 0.0 3 21 high temp 1 1 1 430.0 1.01
Computed 600.0 - -
1188 NO.2 A/E EXH GAS TEMP OUT CYL2 ?C 0.0 3 21 high temp 1 2 2 430.0 1.01
AI 0_600D 600.0 - -
1188A NO.2 A/E CLY2 EXH GAS TEMP DEV ?C -100.0 3 21 low temp 1 2 2 -50.0 1.02
Computed 100.0 - - high temp 1 2 2 50.0
1189 NO.2 A/E EXH GAS TEMP OUT CYL3 ?C 0.0 3 21 high temp 1 2 2 430.0 1.01
AI 0_600D 600.0 - -
1189A NO.2 A/E CLY3 EXH GAS TEMP DEV ?C -100.0 3 21 low temp 1 2 2 -50.0 1.02
Computed 100.0 - - high temp 1 2 2 50.0
1190 NO.2 A/E EXH GAS TEMP OUT CYL4 ?C 0.0 3 21 high temp 1 2 2 430.0 1.01
AI 0_600D 600.0 - -
1190A NO.2 A/E CLY4 EXH GAS TEMP DEV ?C -100.0 3 21 low temp 1 2 2 -50.0 1.02
Computed 100.0 - - high temp 1 2 2 50.0
1191 NO.2 A/E EXH GAS TEMP OUT CYL5 ?C 0.0 3 21 high temp 1 2 2 430.0 1.01
AI 0_600D 600.0 - -
1191A NO.2 A/E CLY5 EXH GAS TEMP DEV ?C -100.0 3 21 low temp 1 2 2 -50.0 1.02
Computed 100.0 - - high temp 1 2 2 50.0
1192 NO.2 A/E EXH GAS TEMP OUT CYL6 ?C 0.0 3 21 high temp 1 2 2 430.0 1.01
AI 0_600D 600.0 - -
1192A NO.2 A/E CLY6 EXH GAS TEMP DEV ?C -100.0 3 21 low temp 1 2 2 -50.0 1.02
Computed 100.0 - - high temp 1 2 2 50.0
1193 NO.3 A/E EXH GAS TEMP OUT CYL1 ?C 0.0 3 22 high temp 1 2 2 430.0 1.01
AI 0_600D 600.0 - -
1193A NO.3 A/E CLY1 EXH GAS TEMP DEV ?C -100.0 3 22 low temp 1 2 2 -50.0 1.02
Computed 100.0 - - high temp 1 2 2 50.0
1193AV NO.3 AE CYL. EXH. GAS.TEMP.AV ?C 0.0 3 21 high temp 1 1 1 430.0 1.01
Computed 600.0 - -
1194 NO.3 A/E EXH GAS TEMP OUT CYL2 ?C 0.0 3 22 high temp 1 2 2 430.0 1.01
AI 0_600D 600.0 - -
1194A NO.3 A/E CLY2 EXH GAS TEMP DEV ?C -100.0 3 22 low temp 1 2 2 -50.0 1.02
Computed 100.0 - - high temp 1 2 2 50.0

Lyngso Marine A/S 651299 Printed: 2005-6-11


Monitoring Channels Report Page
Limit Related Parameters 9 / 33
ID Name Unit
Delay
Type Yard ID Scaling Disp Range Alm Grp Mess. Text Prio On Off Limit Suppression Rev.
1195 NO.3 A/E EXH GAS TEMP OUT CYL3 ?C 0.0 3 22 high temp 1 2 2 430.0 1.01
AI 0_600D 600.0 - -
1195A NO.3 A/E CLY3 EXH GAS TEMP DEV ?C -100.0 3 22 low temp 1 2 2 -50.0 1.02
Computed 100.0 - - high temp 1 2 2 50.0
1196 NO.3 A/E EXH GAS TEMP OUT CYL4 ?C 0.0 3 22 high temp 1 2 2 430.0 1.01
AI 0_600D 600.0 - -
1196A NO.3 A/E CLY4 EXH GAS TEMP DEV ?C -100.0 3 22 low temp 1 2 2 -50.0 1.02
Computed 100.0 - - high temp 1 2 2 50.0
1197 NO.3 A/E EXH GAS TEMP OUT CYL5 ?C 0.0 3 22 high temp 1 2 2 430.0 1.01
AI 0_600D 600.0 - -
1197A NO.3 A/E CLY5 EXH GAS TEMP DEV ?C -100.0 3 22 low temp 1 2 2 -50.0 1.02
Computed 100.0 - - high temp 1 2 2 50.0
1198 NO.3 A/E EXH GAS TEMP OUT CYL6 ?C 0.0 3 22 high temp 1 2 2 430.0 1.01
AI 0_600D 600.0 - -
1198A NO.3 A/E CLY6 EXH GAS TEMP DEV ?C -100.0 3 22 low temp 1 2 2 -50.0 1.02
Computed 100.0 - - high temp 1 2 2 50.0
1200 MSB VOLTAGE H/L AL 3 23 alarm 1 2 1 1.02
DI NC - -
1201 MSB FREQUENCY H/L AL 3 23 alarm 1 2 1 1.02
DI NC - -
1202 MSB PREFERENTIAL TRIP AL 3 23 alarm 1 2 1 1.02
DI NC - -
1203 EARTH LEAKAGE MSB AC440V 3 23 alarm 1 2 1 1.02
DI NC - -
1204 EARTH LEAKAGE MSB AC 220V 3 23 alarm 1 2 1 1.02
DI NC - -
1205 MSB 24V DC & PLC FAIL 3 23 alarm 1 2 1 1.02
DI NC - -
1206 MSB EM'CY ST/PRE SYS.PWR FAIL 3 23 alarm 1 2 1 1.02
DI NC - -
1208 EM'CY STOP SYS.ESB PWR FAIL 3 23 alarm 1 2 1 1.02
DI NC - -
1209 EARTH LEAKAGE ESB AC220V 3 23 alarm 1 2 1 1.02
DI NC - -

Lyngso Marine A/S 651299 Printed: 2005-6-11


Monitoring Channels Report Page
Limit Related Parameters 10 / 33
ID Name Unit
Delay
Type Yard ID Scaling Disp Range Alm Grp Mess. Text Prio On Off Limit Suppression Rev.
1210 ECC AC220V POWER FAILURE 3 23 alarm 1 2 1 1.02
DI NC - -
1211 AIR COND.HEAT SYS.EARTH LEAK 3 23 alarm 1 2 1 1.02
DI NC - -
1212 CHP FAILURE - 23 alarm 1 2 1 1.02
DI NC - -
1213 CHP DC24V EARTH LEAKAGE - 23 alarm 1 2 1 1.02
DI NC - -
1214 EM'CY GEN BATTERY FAILURE 3 23 alarm 1 2 1 1.02
DI NC - -
1215 NAV LIGHT INDI PANEL PWR ABN. - 23 alarm 1 2 1 1.02
DI NC - -
1216 WCP POWER FAILURE - 23 alarm 1 2 1 1.02
DI NC - -
1217 ER. AUTO.SYS UPS POWER FAIL 3 11 alarm 1 2 1 1.02
DI NC - -
1300 EM'CY GEN COMM ALARM 3 24 alarm 1 2 1 1.02
DI NC - -
1308 EM'CY GEN.D.O.TK.L.L 3 24 alarm 1 2 1 1.02
DI NC - -
1400 NO.1 S/G CONTROL POWER FAIL 3 25 alarm 1 2 1 1.02
DI NC - -
1401 NO.2 S/G CONTROL POWER FAIL 3 25 alarm 1 2 1 1.02
DI NC - -
1402 NO.1 S/G OVERLOAD 3 25 alarm 1 2 1 1.02
DI NC - -
1403 NO.2 S/G OVERLOAD 3 25 alarm 1 2 1 1.02
DI NC - -
1404 NO.1 S/G PHASE FAIL/NO VOLTAGE 3 25 alarm 1 2 1 1.02
DI NC - -
1405 NO.2 S/G PHASE FAIL/NO VOLTAGE 3 25 alarm 1 2 1 1.02
DI NC - -
1407 S/G STAND BY UNIT AUTO CUT-IN 3 25 alarm 1 2 1 1.02
DI NC - -

Lyngso Marine A/S 651299 Printed: 2005-6-11


Monitoring Channels Report Page
Limit Related Parameters 11 / 33
ID Name Unit
Delay
Type Yard ID Scaling Disp Range Alm Grp Mess. Text Prio On Off Limit Suppression Rev.
1408 NO.1 S/G OIL TK.L.L 3 25 alarm 1 2 1 1.02
DI NC - -
1409 NO.2 S/G OIL TK.L.L 3 25 alarm 1 2 1 1.02
DI NC - -
1500 A/B BURNER SHUT DOWN 3 26 alarm 1 2 1 1.02
DI NC - -
1501 BOILER POWER FAILURE 3 26 alarm 1 2 1 1.02
DI NC - -
1502 A/B FUEL OIL PL 3 26 alarm 1 2 1 1.02
DI NC - -
1503 A/B FUEL OIL INLET H/LT 3 26 alarm 1 2 1 1.02
DI NC - -
1504 A/B WATER LOW LOW 3 26 alarm 1 15 1 1.02
DI NC - -
1505 A/B WATER LOW/HIGH 3 26 alarm 1 15 1 1.02
DI NC - -
1506 A/B ST/BY OIL PUMP START 3 26 alarm 1 2 1 1.02
DI NC - -
1507 A/B ST/BY WATER PUMP START 3 26 alarm 1 2 1 1.02
DI NC - -
1508 EXH GAS BOILER WATER LOW LOW 3 26 alarm 1 15 1 1.02
DI NC - -
1509 EXH GAS BOILER WATER LOW 3 26 alarm 1 15 1 1.02
DI NC - -
1510 A/B STEAM PRESSURE HIGH/LOW 3 26 alarm 1 2 1 1.02
DI NC - -
1511 EXH GAS BOIL.ST/BY W.PMP STRT 3 26 alarm 1 2 1 1.02
DI NC - -
1512 BLR FD WTR OIL CONT / SALINITY 3 26 high alm 1 2 1 1.02
DI NC - -
1513 BOILER FEED W.CASCADE TK.LL 3 26 alarm 1 15 1 1.02
DI NC - -
1514 EXH GAS BOILER STEAM HIGH/LOW 3 26 alarm 1 2 2 MESTOP1 1.02
DI NC - -

Lyngso Marine A/S 651299 Printed: 2005-6-11


Monitoring Channels Report Page
Limit Related Parameters 12 / 33
ID Name Unit
Delay
Type Yard ID Scaling Disp Range Alm Grp Mess. Text Prio On Off Limit Suppression Rev.
1515 AUX.BOILER F.O.INLET L.T 26 - alarm 1 1 1 1.02
DI NC - -
1516 AUX.BOILER WATER LEVEL L.L 26 - alarm 1 1 1 1.02
DI NC - -
1517 AUX.BOILER FAN OVERLOAD 26 - alarm 1 1 1 1.02
DI NC - -
1518 AUX.BOILER FRAME FAILURE 26 - alarm 1 1 1 1.02
DI NC - -
1601 MAIN LO ST/BY PUMP START 3 14 alarm 1 2 1 1.02
DI NC - -
1602 MAIN S.W.ST/BY PUMP START 3 12 alarm 1 2 1 1.01
DI NC - -
1603 M/E H.T.F.W.ST/BY PUMP START 3 12 alarm 1 2 1 1.01
DI NC - -
1604 M/E L.T.F.W.ST/BY PUMP START 3 12 alarm 1 2 1 1.01
DI NC - -
1605 IGS DECK W.SEAL ST/BY PMP ST 8 30 alarm 1 2 1 1.02
DI NC - -
1701 VAPOUR CONT.SYS.COMM ALARM 8 30 alarm 1 2 1 1.02
DI NC - -
1702 ODME SYSEM FAIL&15PPM ALARM 8 30 alarm 1 2 1 1.02
DI NC - -
1703 GAS DETECT.SYS.COMM ALARM 8 30 alarm 1 2 1 1.02
DI NC - -
1704 HHL ALARM SYS POWER FAILURE 8 30 alarm 1 2 1 1.02
DI NC - -
1705 IGS PLANT FAIL 8 30 alarm 1 2 1 1.02
DI NC - -
1706 IGS PWR FAIL 8 30 alarm 1 2 1 1.02
DI NC - -
1707 IGS OXY.CONTENT FAIL 8 30 alarm 1 2 1 1.02
DI NC - -
1708 IGS DECK MAIN LINE LPL 8 30 alarm 1 2 1 1.02
DI NC - -

Lyngso Marine A/S 651299 Printed: 2005-6-11


Monitoring Channels Report Page
Limit Related Parameters 13 / 33
ID Name Unit
Delay
Type Yard ID Scaling Disp Range Alm Grp Mess. Text Prio On Off Limit Suppression Rev.
1709 CARGO SYS.POWER FAIL 8 30 alarm 1 2 1 1.02
DI NC - -
1710 CARGO/BALLAST SYS.FAIL 8 30 alarm 1 2 1 1.02
DI NC - -
1711 CARGO TANKS LH 8 30 alarm 1 2 1 1.02
DI NC - -
1712 CARGO TANKS PRESS./TEMP ALARM 8 30 alarm 1 2 1 1.02
DI NC - -
1713 CARGO TANK RADAR SYS.FAIL 8 30 alarm 1 2 1 1.02
DI NC - -
1714 NO.1 CARGO CONV.COMM ALARM 8 30 alarm 1 2 1 1.02
DI NC - -
1715 NO.2 CARGO CONV.COMM ALARM 8 30 alarm 1 2 1 1.02
DI NC - -
1716 HYD UNIT FOR R.V.C.SYS AL 8 30 alarm 1 2 1 1.02
DI NC - -
1801 FIRE ALARM 4 31 alarm 1 2 1 1.02
DI NC - -
1802 FIRE ALARM CONT PANEL FAIL 3 31 alarm 1 2 1 1.02
DI NC - -
1803 CO2 SYSTEM FAILURE 3 31 alarm 1 2 1 1.01
DI NC - -
1804 CO2 ROOM EXH.FAN FAIL 3 31 alarm 1 2 1 1.01
DI NC - -
1902 QUICKLY CLOSE VALVE AIR PL. 3 28 alarm 1 2 1 1.02
DI NC - -
1910 S/G ROOM BILGE WELL LH 7 29 alarm 1 15 1 1.02
DI NC - -
1911 B/T ROOM BILGE WELL LH 7 29 alarm 1 15 1 1.02
DI NC - -
1912 BOSUN STORE BILGE WELL LH 7 29 alarm 1 15 1 1.02
DI NC - -
1913 BALLAST P/R BILGE WELL LH 7 29 alarm 1 15 1 1.02
DI NC - -

Lyngso Marine A/S 651299 Printed: 2005-6-11


Monitoring Channels Report Page
Limit Related Parameters 14 / 33
ID Name Unit
Delay
Type Yard ID Scaling Disp Range Alm Grp Mess. Text Prio On Off Limit Suppression Rev.
1914 E.F.P.R. BILGE WELL HIGH LEVEL 7 29 alarm 1 15 1 1.02
DI NC - -
1915 FRESH WATER TANK(PS) LOW LEVEL 8 32 alarm 1 15 1 1.02
DI NC - -
1916 FRESH WATER TANK(SB) LOW LEVEL 8 32 alarm 1 15 1 1.02
DI NC - -
1920 F.W.EXPANSION TANK LL 8 12 alarm 1 15 1 1.02
DI NC - -
1921 CYL OIL MEASURE TANK LL 3 14 alarm 1 15 1 1.01
DI NC - -
1922 NO.1 PS HFO TANK LH 3 13 alarm 1 15 1 1.01
DI NC - -
1923 NO.2 PS HFO TANK LH 3 13 alarm 1 15 1 1.01
DI NC - -
1924 NO.1 SB HFO TANK LH 3 13 alarm 1 15 1 1.01
DI NC - -
1925 NO.2 SB HFO TANK LH 3 13 alarm 1 15 1 1.01
DI NC - -
1926 HFO MINOR TANK LH 3 13 alarm 1 15 1 1.01
DI NC - -
1927 PUBLIC ADDRESS COM. ALARM 8 - alarm 1 1 1 1.02
DI NC - -
1928 BOW THRUSTER COMM ALARM 8 32 alarm 1 2 1 1.02
DI NC - -
1929 PROV.REEF.PLANT SYS.FAILURE 8 32 alarm 1 2 1 1.02
DI NC - -
1930 AUTO PILOT POWER ABNORMAL 8 32 alarm 1 2 1 1.02
DI NC - -
1931 #1 GYRO COMPASS POWER FAIL 8 32 alarm 1 2 1 1.02
DI NC - -
1932 #2 GYRO COMPASS POWER FAIL 8 32 alarm 1 2 1 1.02
DI NC - -
1933 RUDDER ANGLE SYS POWER FAIL 8 32 alarm 1 2 1 1.02
DI NC - -

Lyngso Marine A/S 651299 Printed: 2005-6-11


Monitoring Channels Report Page
Limit Related Parameters 15 / 33
ID Name Unit
Delay
Type Yard ID Scaling Disp Range Alm Grp Mess. Text Prio On Off Limit Suppression Rev.
1935 M/E TELEGRAPH SYS.POWER FAIL 5 11 alarm 1 2 2 1.02
DI NC - -
1936 M/E TELEGRAPH ALARM - 11 alarm 1 5 1 1.02
DI NC - -
2003 M/E CONTROL SYS(DMS) ALARM 5 11 alarm 1 2 2 1.02
DI NC - -
2004 M/E SAFETY SYSTEM (DPS) FAIL 5 11 alarm 1 2 2 1.02
DI NC - -
2006 M/E ELECTRIC GOVERNOR FAIL 5 11 alarm 1 2 2 1.02
DI NC - -
2009 MANUAL REDUCE RPM 6 - released 1 1 1 1.02
Computed - -
2010 M/E OIL MIST DETECTOR FAILURE 3 14 alarm 1 2 2 1.02
DI NC - -
2011 M/E HIGH OIL MIST IN CRNKC. AL 3 14 alarm 1 2 2 1.02
DI NC - -
2013 M/E AXIAL VIBRATION HIGH mm 0.00 3 19 high alm 1 5 1 2.50 1.02
AI AXIAL 10.00 - -
2014 M/E AXIAL VIBRATION MON.SLD - 14 slow down 1 2 2 1.02
DI NO 2 -
2015 M/E TURBO CHARGER RPM rpm 0 3 17 alarm 1 2 2 16500 1.02
AI TC_RPM 20000 - -
2016 M/E AUX BLOWER ABN STOP ALM 3 11 alarm 1 2 2 1.02
DI NC - -
2100 M/E J.C.F.W.INL.PRESS PL/SLD bar 0.0 2 12 low pres 1 2 2 2.0 1.02
AI 0_6 6.0 - - low low 1 2 2 1.5
2101 M/E J.C.F.W.INL.T. LT ?C 0.0 3 12 low temp 1 2 2 57.0 1.02
AI PT100_2 100.0 - -
2102 M/E C.F.W.INL.AIR COOL.PL bar 0.0 3 12 low pres 1 2 2 1.0 1.01
AI 0_6 6.0 - -
2103 M/E C.F.W.INL.AIR COOL.T. TH ?C 0.0 3 12 high temp 1 2 2 40.0 1.02
AI PT100_2 100.0 - -
2104 M/E CYL.1 C.F.W.OUT T.TH/SLD ?C 0.0 - 12 high temp 1 2 2 90.0 1.02
AI PT100_2 100.0 2 71 slow down 1 2 2 95.0

Lyngso Marine A/S 651299 Printed: 2005-6-11


Monitoring Channels Report Page
Limit Related Parameters 16 / 33
ID Name Unit
Delay
Type Yard ID Scaling Disp Range Alm Grp Mess. Text Prio On Off Limit Suppression Rev.
2105 M/E CYL.2 C.F.W.OUT T.TH/ SLD ?C 0.0 - 12 high temp 1 2 2 90.0 1.02
AI PT100_2 100.0 2 71 slow down 1 2 2 95.0
2106 M/E CYL.3 C.F.W.OUT T.TH/ SLD ?C 0.0 - 12 high temp 1 2 2 90.0 1.02
AI PT100_2 100.0 2 71 slow down 1 2 2 95.0
2107 M/E CYL.4 C.F.W.OUT T.TH/ SLD ?C 0.0 - 12 high temp 1 2 2 90.0 1.02
AI PT100_2 100.0 2 71 slow down 1 2 2 95.0
2108 M/E CYL.5 C.F.W.OUT T.TH/ SLD ?C 0.0 - 12 high temp 1 2 2 90.0 1.02
AI PT100_2 100.0 2 71 slow down 1 2 2 95.0
2109 M/E CYL.6 C.F.W.OUT T.TH/ SLD ?C 0.0 - 12 high temp 1 2 2 90.0 1.02
AI PT100_2 100.0 2 71 slow down 1 2 2 95.0
2110 M/E C.F.W.DIFT.P. ACR.ENG.LDP 3 12 alarm 1 2 2 MESTOP 1.02
DI NC - -
2111 M/E F.O.INL.PRESS PL bar 0.0 3 13 low pres 1 2 2 6.5 1.01
AI 0_16 16.0 - -
2112 M/E CYL 1 H.P. F.O.PIPE LEAK 3 13 alarm 1 2 2 1.01
DI NC - -
2113 M/E CYL 2 H.P. F.O.PIPE LEAK 3 13 alarm 1 2 2 1.01
DI NC - -
2114 M/E CYL.3 H.P. F.O.PIPE LEAK 3 13 alarm 1 2 2 1.01
DI NC - -
2115 M/E CYL.4 H.P. F.O.PIPE LEAK 3 13 alarm 1 2 2 1.01
DI NC - -
2116 M/E CYL 5 H.P. F.O.PIPE LEAK 3 13 alarm 1 2 2 1.01
DI NC - -
2117 M/E CYL 6 H.P. F.O.PIPE LEAK 3 13 alarm 1 2 2 1.01
DI NC - -
2120 M/E L.O.INL.PRESS PL/SLD bar 0.0 - 14 low pres 1 2 2 1.6 1.02
AI 0_4 4.0 2 - slow down 1 2 2 1.4
2121 M/E L.O.INL.T. TH/SLD ?C 0.0 - 14 high temp 1 2 2 55.0 1.02
AI PT100_2 100.0 2 - high high 1 2 2 60.0
2122 M/E NO.1 LUBRICATOR LEVEL LL 3 14 alarm 1 2 2 MESTOP 1.02
DI NC - -
2123 M/E NO.1 LUBRICATOR NO FL SLD - 14 alarm 1 10 1 MESTOP 1.02
DI NC 2 72

Lyngso Marine A/S 651299 Printed: 2005-6-11


Monitoring Channels Report Page
Limit Related Parameters 17 / 33
ID Name Unit
Delay
Type Yard ID Scaling Disp Range Alm Grp Mess. Text Prio On Off Limit Suppression Rev.
2124 M/E NO.2 LUBRICATOR LEVEL LL 3 14 alarm 1 2 2 MESTOP 1.02
DI NC - -
2125 M/E NO.2 LUBRICATOR NO FL SLD - 14 alarm 1 10 1 MESTOP 1.02
DI NC 2 72
2126 M/E T/C L.O. INLET PRESSURE LP bar 0.0 6 14 low pres 1 2 2 1.6 1.02
AI 0_4 4.0 85 -
2127 M/E T/C LO OUTLET TEMP HT/SLD ?C 0.0 6 15 high temp 1 2 2 70.0 1.02
AI PT100_2 100.0 85 - high high 1 2 2 75.0
2130 M/E CYL1 P.C.O OUT T. TH/SLD ?C 0.0 - 15 high temp 1 2 2 70.0 1.02
AI PT100_2 100.0 2 73 slow down 1 2 2 75.0
2131 M/E CYL2 P.C.O OUT T. TH/SLD ?C 0.0 - 15 high temp 1 2 2 70.0 1.02
AI PT100_2 100.0 2 73 slow down 1 2 2 75.0
2132 M/E CYL3 P.C.O OUT T. TH/SLD ?C 0.0 - 15 high temp 1 2 2 70.0 1.02
AI PT100_2 100.0 2 73 slow down 1 2 2 75.0
2133 M/E CYL4 P.C.O OUT T. TH/SLD ?C 0.0 - 15 high temp 1 2 2 70.0 1.02
AI PT100_2 100.0 2 73 slow down 1 2 2 75.0
2134 M/E CYL5 P.C.O OUT T. TH/SLD ?C 0.0 - 15 high temp 1 2 2 70.0 1.02
AI PT100_2 100.0 2 73 slow down 1 2 2 75.0
2135 M/E CYL6 P.C.O OUT T. TH/SLD ?C 0.0 - 15 high temp 1 2 2 70.0 1.02
AI PT100_2 100.0 2 73 slow down 1 2 2 75.0
2136 M/E CYL1 P.C.O OUT FLOW LF/SLD - 15 alarm 1 2 2 1.02
DI NC 2 74
2137 M/E CYL2 P.C.O OUT FLOW LF/SLD - 15 alarm 1 2 2 1.02
DI NC 2 74
2138 M/E CYL3 P.C.O OUT FLOW LF/SLD - 15 alarm 1 2 2 1.02
DI NC 2 74
2139 M/E CYL4 P.C.O OUT FLOW LF/SLD - 15 alarm 1 2 2 1.02
DI NC 2 74
2140 M/E CYL5 P.C.O OUT FLOW LF/SLD - 15 alarm 1 2 2 1.02
DI NC 2 74
2141 M/E CYL6 P.C.O OUT FLOW LF/SLD - 15 alarm 1 2 2 1.02
DI NC 2 74
2151 M/E EXH GAS A.T/C T. TH ?C 0.0 3 16 high temp 1 2 2 350.0 1.02
AI PT100_3 600.0 - -

Lyngso Marine A/S 651299 Printed: 2005-6-11


Monitoring Channels Report Page
Limit Related Parameters 18 / 33
ID Name Unit
Delay
Type Yard ID Scaling Disp Range Alm Grp Mess. Text Prio On Off Limit Suppression Rev.
2152 M/E EXH GAS A.CYL 1 T. TH/SLD ?C 0.0 - 16 high temp 1 2 2 430.0 1.02
AI PT100_3 600.0 2 75 slow down 1 2 2 450.0
2153 M/E EXH GAS A.CYL 2 T. TH/SLD ?C 0.0 - 16 high temp 1 2 2 430.0 1.02
AI PT100_3 600.0 2 75 slow down 1 2 2 450.0
2154 M/E EXH GAS A.CYL 3 T. TH/SLD ?C 0.0 - 16 high temp 1 2 2 430.0 1.02
AI PT100_3 600.0 2 75 slow down 1 2 2 450.0
2155 M/E EXH GAS A.CYL 4 T. TH/SLD ?C 0.0 - 16 high temp 1 2 2 430.0 1.02
AI PT100_3 600.0 2 75 slow down 1 2 2 450.0
2156 M/E EXH GAS A.CYL 5 T. TH/SLD ?C 0.0 - 16 high temp 1 2 2 430.0 1.02
AI PT100_3 600.0 2 75 slow down 1 2 2 450.0
2157 M/E EXH GAS A.CYL 6 T. TH/SLD ?C 0.0 - 16 high temp 1 2 2 430.0 1.02
AI PT100_3 600.0 2 75 slow down 1 2 2 450.0
2158 M/E EXH GAS A.CYL 1 TEMP DEV ?C -100.0 3 16 low temp 1 2 2 -50.0 2163AV 1.02
Computed 100.0 - - high temp 1 2 2 50.0 2163AV
2158A M/E EXH GAS A.CYL 1 TEMP DEV ?C -100.0 3 16 slow down 1 2 2 -60.0 2163AV 1.02
Computed 100.0 77 2 slow down 1 2 2 60.0 2163AV
2159 M/E EXH GAS A.CYL 2 TEMP DEV ?C -100.0 3 16 low temp 1 2 2 -50.0 2163AV 1.02
Computed 100.0 - - high temp 1 2 2 50.0 2163AV
2159A M/E EXH GAS A.CYL 2 TEMP DEV ?C -100.0 3 16 slow down 1 2 2 -60.0 2163AV 1.02
Computed 100.0 77 2 slow down 1 2 2 60.0 2163AV
2160 M/E EXH GAS A.CYL 3 TEMP DEV ?C -100.0 3 16 low temp 1 2 2 -50.0 2163AV 1.02
Computed 100.0 - - high temp 1 2 2 50.0 2163AV
2160A M/E EXH GAS A.CYL 3 TEMP DEV ?C -100.0 3 16 slow down 1 2 2 -60.0 2163AV 1.02
Computed 100.0 77 2 slow down 1 2 2 60.0 2163AV
2161 M/E EXH GAS A.CYL 4 TEMP DEV ?C -100.0 3 16 low temp 1 2 2 -50.0 2163AV 1.02
Computed 100.0 - - high temp 1 2 2 50.0 2163AV
2161A M/E EXH GAS A.CYL 4 TEMP DEV ?C -100.0 3 16 slow down 1 2 2 -60.0 2163AV 1.02
Computed 100.0 77 2 slow down 1 2 2 60.0 2163AV
2162 M/E EXH GAS A.CYL 5 TEMP DEV ?C -100.0 3 16 low temp 1 2 2 -50.0 2163AV 1.02
Computed 100.0 - - high temp 1 2 2 50.0 2163AV
2162A M/E EXH GAS A.CYL 5 TEMP DEV ?C -100.0 3 16 slow down 1 2 2 -60.0 2163AV 1.02
Computed 100.0 77 2 slow down 1 2 2 60.0 2163AV
2163 M/E EXH GAS A.CYL 6 TEMP DEV ?C -100.0 3 16 low temp 1 2 2 -50.0 2163AV 1.02
Computed 100.0 - - high temp 1 2 2 50.0 2163AV

Lyngso Marine A/S 651299 Printed: 2005-6-11


Monitoring Channels Report Page
Limit Related Parameters 19 / 33
ID Name Unit
Delay
Type Yard ID Scaling Disp Range Alm Grp Mess. Text Prio On Off Limit Suppression Rev.
2163A M/E EXH GAS A.CYL 6 TEMP DEV ?C -100.0 3 16 slow down 1 2 2 -60.0 2163AV 1.02
Computed 100.0 77 2 slow down 1 2 2 60.0 2163AV
2163AV M/E CYL. EXH. GAS.TEMP.AVERAGE ?C 0.0 - 16 high temp 1 1 1 430.0 1.02
Computed 600.0 - - low temp 4 1 1 200.0
2165 M/E CYL 1 SC.A.T.- FIRE TH/SLD ?C -50.0 - 17 high temp 1 2 2 80.0 1.02
AI PT100_2 200.0 2 76 slow down 1 2 2 120.0
2166 M/E CYL 2 SC.A.T.- FIRE TH/SLD ?C -50.0 - 17 high temp 1 2 2 80.0 1.02
AI PT100_2 200.0 2 76 slow down 1 2 2 120.0
2167 M/E CYL 3 SC.A.T.- FIRE TH/SLD ?C -50.0 - 17 high temp 1 2 2 80.0 1.02
AI PT100_2 200.0 2 76 slow down 1 2 2 120.0
2168 M/E CYL 4 SC.A.T.- FIRE TH/SLD ?C -50.0 - 17 high temp 1 2 2 80.0 1.02
AI PT100_2 200.0 2 76 slow down 1 2 2 120.0
2169 M/E CYL 5 SC.A.T.- FIRE TH/SLD ?C -50.0 - 17 high temp 1 2 2 80.0 1.02
AI PT100_2 200.0 2 76 slow down 1 2 2 120.0
2170 M/E CYL 6 SC.A.T.- FIRE TH/SLD ?C -50.0 - 17 high temp 1 2 2 80.0 1.02
AI PT100_2 200.0 2 76 slow down 1 2 2 120.0
2171 M/E SC.A.REC.PL bar 0.0 3 17 1.02
AI 0_4 4.0 - -
2172 M/E SC.A.REC.WATER H.LEVEL 3 17 high lvl 1 2 2 1.02
DI NC - -
2173 M/E STARTING AIR INL.PL bar 0.0 3 18 low pres 1 2 2 15.0 1.02
AI 0_40 40.0 - -
2175 M/E CONTROL AIR INL.PL bar 0.0 3 18 low pres 1 2 2 5.5 1.01
AI 0_10 10.0 - -
2176 M/E CONTROL AIR INL.FWE HIGH 3 18 alarm 1 2 2 NFWE 1.02
DI NC - -
2177 M/E SAFETY AIR INL.PL bar 0.0 3 18 alarm 1 2 2 0.0 1.02
AI 0_10 10.0 - -
2178 M/E SAFETY AIR INL.FWE HIGH 3 18 alarm 1 2 2 NFWE 1.02
DI NC - -
2179 M/E EXH V.A.I.TO A.C.PL/SLD - 18 low pres 1 2 2 1.02
DI NC 2 -
2181 M/E THR.BEAR.SEG.AH T. TH/SLD ?C -50.0 2 19 high temp 1 2 2 75.0 1.02
AI PT100_2 200.0 - - slow down 1 2 2 80.0

Lyngso Marine A/S 651299 Printed: 2005-6-11


Monitoring Channels Report Page
Limit Related Parameters 20 / 33
ID Name Unit
Delay
Type Yard ID Scaling Disp Range Alm Grp Mess. Text Prio On Off Limit Suppression Rev.
2182 INTERMEDIATE SHAFT BRG.TH. ?C -50.0 6 19 high temp 1 2 2 65.0 1.02
AI PT100_2 200.0 85 - high high 1 2 2 70.0
2183 STERN TUBE FORE BEARING TH. ?C -50.0 6 19 high temp 1 2 2 60.0 1.02
AI PT100_2 200.0 85 - high high 1 2 2 65.0
2184 STERN TUBE AFT BEARING TH. ?C -50.0 6 19 high temp 1 2 2 60.0 1.02
AI PT100_2 200.0 85 - high high 1 2 2 65.0
2201 NO.1 FO PURIFIER ABN 3 27 alarm 1 2 2 1.01
DI NC - -
2202 NO.1 FO PURIFIER VIBRATION 3 27 alarm 1 2 2 1.01
DI NC - -
2203 NO.2 FO PURIFIER ABN 3 27 alarm 1 2 2 1.01
DI NC - -
2204 NO.2 FO PURIFIER VIBRATION 3 27 alarm 1 2 2 1.01
DI NC - -
2205 DO PURIFIER ABN 3 27 alarm 1 2 2 1.02
DI NC - -
2206 DO PURIFIER VIBRATION 3 27 alarm 1 2 2 1.02
DI NC - -
2207 NO.1M/E LO PURIFIER ABN 3 27 alarm 1 2 2 1.01
DI NC - -
2208 NO.1M/E LO PURIFIER VIBRATION 3 27 alarm 1 2 2 1.01
DI NC - -
2209 NO.2 M/E LO PURIFIER ABN 3 27 alarm 1 2 2 1.01
DI NC - -
2210 NO.2 M/E LO PURIFIER VIBRATION 3 27 alarm 1 2 2 1.01
DI NC - -
2211 A/E LO PURIFIER ABN 3 27 alarm 1 2 2 1.01
DI NC - -
2212 A/E LO PURIFIER VIBRATION 3 27 alarm 1 2 2 1.01
DI NC - -
2213 FO BOOSTER UNIT COMM ALARM 3 13 alarm 1 2 2 1.01
DI NC - -
2214 FO AUTO FILTER DIFF HP. 3 13 alarm 1 2 2 1.01
DI NC - -

Lyngso Marine A/S 651299 Printed: 2005-6-11


Monitoring Channels Report Page
Limit Related Parameters 21 / 33
ID Name Unit
Delay
Type Yard ID Scaling Disp Range Alm Grp Mess. Text Prio On Off Limit Suppression Rev.
2215 FO VISCOSITY HIGH/LOW 3 13 alarm 1 2 2 1.01
DI NC - -
2218 MAIN LO A.FILT.DIFF HP. 3 14 alarm 1 2 2 1.01
DI NC - -
2219 SEWAGE TREAT.C.P FAILURE 8 32 alarm 1 2 2 1.02
DI NC - -
2220 F.W.GEN.DIST.WATER SAL.HIGH 8 32 alarm 1 2 2 1.02
DI NC - -
2221 BILGE WATER SEPARATOR FAIL 7 32 alarm 1 2 2 1.02
DI NC - -
2300 NO.1 MAIN AIR COMP.ABN 3 28 alarm 1 2 2 1.01
DI NC - -
2301 NO.2 MAIN AIR COMP.ABN 3 28 alarm 1 2 2 1.01
DI NC - -
2302 WORK AIR COMPRESSOR ABN 3 28 alarm 1 2 2 1.01
DI NC - -
2304 WORK AIR DRYER FAILURE 3 18 alarm 1 2 2 1.01
DI NC - -
2305 #1 MAIN AIR RESEVOIR PL. bar 0.0 3 28 low pres 1 2 2 16.0 1.01
AI 0_40 40.0 - -
2306 #2 MAIN AIR RESEVOIR PL. bar 0.0 3 28 low pres 1 2 2 16.0 1.01
AI 0_40 40.0 - -
2307 AUX AIR RESEVOIR PL. bar 0.0 3 28 low pres 1 2 2 16.0 1.02
AI 0_40 40.0 - -
2308 WORK AIR RESEVOIR PL. bar 0.0 3 28 low pres 1 2 2 5.5 1.02
AI 0_16 16.0 - -
2309 SEA WATER PUMP OUT PL. 3 12 low pres 1 2 2 1.02
DI NC - -
2400 INCINERATOR SLUDGE TANK H.L. 8 32 alarm 1 2 2 1.02
DI NC - -
2401 INCINERAOR COMM ALARM 8 32 alarm 1 2 2 1.02
DI NC - -
2402 AIR CONDITION SYS FAILURE 8 32 alarm 1 2 2 1.02
DI NC - -

Lyngso Marine A/S 651299 Printed: 2005-6-11


Monitoring Channels Report Page
Limit Related Parameters 22 / 33
ID Name Unit
Delay
Type Yard ID Scaling Disp Range Alm Grp Mess. Text Prio On Off Limit Suppression Rev.
2403 WATER SPRINKER SYS FIRE ALARM 8 32 alarm 1 2 2 1.02
DI NC - -
2404 SPRINKLER SYS FAULT ALARM 8 32 alarm 1 2 2 1.02
DI NC - -
2405 SPRINKLER PUMP UNIT FAILURE 32 3 fail 1 1 1 1.02
DI NC - -
2501 M/E FO SETT TANK TH. ?C -50.0 3 13 high temp 1 2 2 80.0 1.01
AI PT100_2 200.0 - -
2502 M/E FO SERV TANK TH. ?C -50.0 3 13 high temp 1 2 2 98.0 1.01
AI PT100_2 200.0 - -
2503 NO.1 PS HFO TANK TH. ?C -50.0 3 13 high temp 1 2 2 55.0 1.01
AI PT100_2 200.0 - -
2504 NO.2 PS HFO TANK TH. ?C -50.0 3 13 high temp 1 2 2 55.0 1.01
AI PT100_2 200.0 - -
2505 NO.1 SB HFO TANK TH. ?C -50.0 3 13 high temp 1 2 2 55.0 1.01
AI PT100_2 200.0 - -
2506 NO.2 SB HFO TANK TH. ?C -50.0 3 13 high temp 1 2 2 55.0 1.01
AI PT100_2 200.0 - -
2507 HFO MINOR TANK TEMP HIGH ?C -50.0 3 13 high temp 1 2 2 55.0 1.02
AI PT100_2 200.0 - -
2508 DIRTY BILGE TANK TEMP HIGH ?C -50.0 3 29 high temp 1 2 2 50.0 1.02
AI PT100_2 200.0 - -
2509 CLEAN BILGE TANK TEMP HIGH ?C -50.0 3 29 high temp 1 2 2 50.0 1.02
AI PT100_2 200.0 - -
2601 M/E SCAV AIR DRAIN TANK LH 3 17 alarm 1 15 15 1.01
DI NC - -
2602 M/E STUFF BOX DRAIN TANK LH 3 14 alarm 1 15 15 1.01
DI NC - -
2603 NO.1DO TANK LH (PS) 3 13 alarm 1 15 15 1.01
DI NC - -
2604 NO.2 DO TANK LH (PS) 3 13 alarm 1 15 15 1.01
DI NC - -
2605 NO.1DO TANK LH (SB) 3 13 alarm 1 15 15 1.01
DI NC - -

Lyngso Marine A/S 651299 Printed: 2005-6-11


Monitoring Channels Report Page
Limit Related Parameters 23 / 33
ID Name Unit
Delay
Type Yard ID Scaling Disp Range Alm Grp Mess. Text Prio On Off Limit Suppression Rev.
2606 M/E LO SUMP TANK LL 3 14 alarm 1 15 15 1.01
DI NC - -
2607 STERN TUBE LO GRAV.TANK LL 3 19 alarm 1 15 15 1.01
DI NC - -
2608 STERN TUBE LO SUMP TANK LL 3 19 alarm 1 15 15 1.01
DI NC - -
2609 M/E JCW DE-AERATED TANK LOW LV 3 12 alarm 1 15 15 1.02
DI NC - -
2610 STERN TUBE FORE SEAL OIL TK LL 3 19 alarm 1 15 15 1.01
DI NC - -
2611 STERN TUBE AFT SEAL OIL TK L 3 19 alarm 1 15 15 1.02
DI NC - -
2612 DO SERVICE TANK LL 3 13 alarm 1 15 15 1.01
DI NC - -
2613 HFO SERVICE TANK LL 3 13 alarm 1 15 15 1.01
DI NC - -
2614 HFO SETTING TANK LH 3 13 alarm 1 15 15 1.01
DI NC - -
2615 HFO SETTING TANK LL 3 13 alarm 1 15 15 1.01
DI NC - -
2616 HFO OVERFLOW TANK LH 3 13 alarm 1 15 15 1.01
DI NC - -
2617 HFO SLUDGE TANK LH 3 13 alarm 1 15 15 1.01
DI NC - -
2618 FO DRAIN TANK LH 3 13 alarm 1 15 15 1.01
DI NC - -
2619 LO DRAIN TANK LH 3 13 alarm 1 15 15 1.01
DI NC - -
2620 LO SLUDGE TANK LH 3 13 alarm 1 15 15 1.01
DI NC - -
2701 E/R FORE PS BILGE WELL LH 7 29 alarm 1 15 15 1.02
DI NC - -
2702 E/R FORE SB BILGE WELL LH 7 29 alarm 1 15 15 1.02
DI NC - -

Lyngso Marine A/S 651299 Printed: 2005-6-11


Monitoring Channels Report Page
Limit Related Parameters 24 / 33
ID Name Unit
Delay
Type Yard ID Scaling Disp Range Alm Grp Mess. Text Prio On Off Limit Suppression Rev.
2703 E/R BELOW M/E BILGE W LH 7 29 alarm 1 15 15 1.02
DI NC - -
2704 E/R AFT BILGE WELL LH 7 29 alarm 1 15 15 1.02
DI NC - -
2705 DIRTY BILGE WATER TANK LH 7 29 alarm 1 15 15 1.02
DI NC - -
2706 CLEAN BILGE WATER TANK LH 7 29 alarm 1 15 15 1.01
DI NC - -
AGP71 J.C.W. OUTLET TEMP HIGH - - active 4 0 0 1.02
Computed - -
AGP72 LUBRICATOR NO FLOW - - active 4 0 0 1.02
Computed - -
AGP73 P.C.O OUTLET TEMP HI - - active 4 0 0 1.02
Computed - -
AGP74 P.C.O OUTLET NO FLOW - - active 4 0 0 1.02
Computed - -
AGP75 EXH GAS TEMP HIGH - - active 4 0 0 1.02
Computed - -
AGP76 SCAV. AIR FIRE - - active 4 0 0 1.02
Computed - -
AGP77SLD M/E EXH GAS DEV SLD - - alarm 1 1 1 1.02
Computed - -
BW_STOP BRIDGE WING STOP HORN - - activated 4 0 1.02
DI NO - -
BW_STOP1 BRIDGE WING STOP HORN - - 4 1.02
Computed - -
DMAS1 DMAS ACTIVE ER COPY - - active 4 0 0 1.02
Computed - -
DMAS2 DMAS WARNING ER COPY - - active 4 0 0 1.02
Computed - -
DMAS3 DMAS WARNING BC COPY - - active 4 0 0 1.02
Computed - -
DMASABC DEADMAN BRIDGE ALARM 32 - alarm 1 30 1 1.02
Computed - -

Lyngso Marine A/S 651299 Printed: 2005-6-11


Monitoring Channels Report Page
Limit Related Parameters 25 / 33
ID Name Unit
Delay
Type Yard ID Scaling Disp Range Alm Grp Mess. Text Prio On Off Limit Suppression Rev.
DMASAER DEADMAN ER ALARM 32 - alarm 1 30 1 1.02
Computed - -
DMASOER DEADMAN ER ON/OFF - - 4 1.02
DI NO - -
DMASRBC DEADMAN BC RESET - - 4 1.02
DI NO - -
DMASRER DEADMAN ER RESET - - 4 1.02
DI NO - -
DMS1AI01 MODULE DMS1AI01 (AEM402) ERROR - - alarm 1 0 0 1.02
Computed 98 99
DMS1C001 MODULE DMS1C001 (SIO) ERROR - - alarm 1 0 0 1.02
Computed 98 99
DMS1C002 MODULE DMS1C002 (DSN) ERROR - - alarm 1 0 0 1.02
Computed 98 99
DMS1M101 MODULE DMS1M101 (IOM402) ERROR - - alarm 1 0 0 1.02
Computed 98 99
DMS1M102 MODULE DMS1M102 (REM401) ERROR - - alarm 1 0 0 1.02
Computed 98 99
DMS1M103 MODULE DMS1M103 (REM401) ERROR - - alarm 1 0 0 1.02
Computed 98 99
DMS1M104 MODULE DMS1M104 (AAM401) ERROR - - alarm 1 0 0 1.02
Computed 98 99
DMSA21F1 AUTM.SUPPLY (IFM401) FUSE F1 - 98 alarm 1 1 1 1.01
DI NC 11 -
DMSA21F2 MAN.SUPPLY (IFM401) FUSE F2 - 98 alarm 1 1 1 1.01
DI NC 11 -
DMSA21F3 SENSOR SUPPLY (IFM401) FUSE F3 - 98 alarm 1 1 1 1.01
DI NC 11 -
DMSA21F4 LPTEST SUPPLY (IFM401) FUSE F4 - 98 alarm 1 0 0 1.01
DI NC 11 -
DMSM101F MODULE DMS1M101 (IOM402) FUSE - 98 alarm 1 0 10 1.02
DI NC 11 -
DMSM102F MODULE DMS1M102 (REM401) FUSE - 98 alarm 1 1 1 1.02
DI NC 11 -

Lyngso Marine A/S 651299 Printed: 2005-6-11


Monitoring Channels Report Page
Limit Related Parameters 26 / 33
ID Name Unit
Delay
Type Yard ID Scaling Disp Range Alm Grp Mess. Text Prio On Off Limit Suppression Rev.
DMSM103F MODULE DMS1M103 (REM401) FUSE - 98 alarm 1 1 1 1.02
DI NC 11 -
DMSMF_SB DMS MALFUNCTION STARTBLOCKING - - block 4 1 1 1.02
Computed - 52
EAD1 COMM. TO ECR - 0 - - 1.01
Computed 15 - 99
EAD2 COMM. TO ECR - 0 - - 1.01
Computed 15 - 99
EGS2000 EGS2000 INTERFACE COMM. ERROR - 98 comm. err 1 1 1 1.01
Computed 11 -
FWE M/E FINISHED WITH ENGINE - - on 4 0 0 1.02
Computed - -
G001MAST GAMMA 1: ALARM NET - 0 - - 1.01
Computed 15 - 99
G001STAT GAMMA1:DATA BASE STATUS - 0 - - 1.01
Computed 15 - 99
G002STAT GAMMA2:DATA BASE STATUS - 0 - - 1.01
Computed 15 - 99
G040STAT GAMMA40:DATA BASE STATUS - 0 - - 1.01
Computed 15 - 99
G40_LOP1 GAMMA 40: COMM. TO PCS PANEL 1 - 0 - - 1.02
Computed 15 - 99
G40_LOP2 GAMMA 40: COMM. TO PCS PANEL 2 - 0 - - 1.02
Computed 15 - 99
GENAL_IN GENERAL ALARM - 32 alarm 1 1 1 1.01
DI NO - -
HABOUR HABOUR MODE - - on 4 1 1 1.02
DI NO - -
LIP3 E/R ALARM OUTPUT - - activated 4 0 0 1.02
Computed - -
LIP4 BMS FAIL ALARM OUTPUT - - activated 4 0 0 1.02
Computed - -
LIP5 REDUCE RPM OUTPUT - - activated 4 0 0 1.02
Computed - -

Lyngso Marine A/S 651299 Printed: 2005-6-11


Monitoring Channels Report Page
Limit Related Parameters 27 / 33
ID Name Unit
Delay
Type Yard ID Scaling Disp Range Alm Grp Mess. Text Prio On Off Limit Suppression Rev.
LIP6 BRIDGE WING HORN OUTPUT - - activated 4 0 0 1.02
Computed - -
MASTG001 ALARM NET TO GAMMA 1 - 0 - - 1.01
Computed 15 - 99
ME1ALARM DMS2100 COMMON ALARM - - alarm 4 1 1 1.02
Computed - -
ME1BCTR ME AUTOMATIC BRIDGE - - alarm 4 1 1 1.02
Computed - -
ME1CFG02 ME STARTING AIR bar 0.00 - - low alarm 1 1 1 15.00 1.02
AI 0_40_DMS 40.00 11 -
ME1ECTR ME MANUAL ECR - - alarm 4 1 1 1.02
Computed - -
ME1LCTR ME IN LOCAL CONTROL - - alarm 4 1 1 1.02
Computed - -
ME1MECRC ME ECR MANUAL LEVER rpm -127.0 5 - 1.02
Computed 127.0 - -
ME1SHD01 ME DPS SHUTDOWN PREWARNING - - prewarn 4 1 1 1.02
DI NC - -
ME1SHD02 ME DPS SHUTDOWN ACTIVE 1 - active 4 1 1 1.01
DI NC - -
ME1SHD04 ME: DPS EMERGENCY STOP - 51 shut down 1 1 1 1.02
DI NC 11 52
ME1SHD05 ME DPS OVERSPEED SHUTDOWN - - shut down 1 1 1 1.02
DI NC 11 52
ME1SP01 ME BRIDGE SETPOINT rpm 0.0 51 - 4 1 5.0 1.02
Computed 150.0 - 52
ME1SP02 ME ECR SETPOINT rpm 0.0 51 - 4 1 5.0 1.02
Computed 150.0 - 52
ME1SP04 ME ME RPM rpm 0.0 51 - 4 1 5.0 1.02
Computed 150.0 - 52
ME1ST03 ME START CMD 5 98 start cmd 4 1 1 1.01
Computed - -
ME1ST04 ME STOP CMD 5 98 stop cmd 4 1 1 1.01
Computed - -

Lyngso Marine A/S 651299 Printed: 2005-6-11


Monitoring Channels Report Page
Limit Related Parameters 28 / 33
ID Name Unit
Delay
Type Yard ID Scaling Disp Range Alm Grp Mess. Text Prio On Off Limit Suppression Rev.
ME1ST05 ME SLOW TURN 5 98 slow turn 4 1 1 1.01
Computed - -
ME1ST07 ME AHEAD VALVE 5 98 ahead 4 1 1 1.01
Computed - -
ME1ST08 ME ASTERN VALVE 5 98 astern 4 1 1 1.00
Computed - -
ME1_BLA ME START BLOCKED - - alarm 1 1 1 1.01
Computed 11 -
ME1_BLC ME START BLOCK CANCELLED - - alarm 1 1 1 1.01
Computed 11 -
ME1_BRGA ME BRG TLG MIS ALIGNED 5 - alarm 1 1 1 1.02
Computed 11 -
ME1_BRGC ME BRG TLG CMD rpm -127.0 5 - 1.02
Computed 127.0 11 -
ME1_CSR1 ME CRITICAL SPEED RANGE 1 - - alarm 1 1 1 1.02
Computed - -
ME1_ECRA ME ECR TLG MIS ALIGNED 5 - alarm 1 1 1 1.02
Computed 11 -
ME1_ECRC ME ECR TLG CMD rpm -127.0 11 - 1.02
Computed 127.0 5 -
ME1_EGS EGS2000 GOVERNOR OFFLINE 5 11 alarm 1 1 1 1.02
DI NC - -
ME1_LIMS ME LIMIT STATUS - 0 - - 1.02
Computed 64 - -
ME1_NOF ME MAX NO START EXCEEDED - - alarm 1 1 1 1.02
Computed 11 52
ME1_POS ME CONTROL POSITION FAIL - - alarm 1 1 1 1.02
Computed 11 -
ME1_PWUP ME POWER UP: PUT TLG. IN STOP 98 - alarm 1 0 300 1.02
Computed 11 -
ME1_REPS ME REPEATED START - - alarm 1 1 1 1.01
Computed 11 -
ME1_RPM1 ME TACHO 1 ERROR - - alarm 1 1 1 1.01
Computed 11 -

Lyngso Marine A/S 651299 Printed: 2005-6-11


Monitoring Channels Report Page
Limit Related Parameters 29 / 33
ID Name Unit
Delay
Type Yard ID Scaling Disp Range Alm Grp Mess. Text Prio On Off Limit Suppression Rev.
ME1_RPM2 ME TACHO 2 ERROR - - alarm 1 1 1 1.01
Computed 11 -
ME1_RPMA ME RPM rpm -150.0 - - 1.02
Computed 150.0 - -
ME1_RSTA ME RUNNING STATUS FOR DISPLAY - 0 - - 1.02
Computed 256 - -
ME1_RUN ME RUNNING - - running 4 1 1 1.02
Computed - -
ME1_SAF ME START AIR TIME EXCEEDED - - alarm 1 1 1 1.01
Computed 11 -
ME1_SBCU ME STARTBLOCK ALARMS CUT-OUT - - cut-out 4 1 1 1.02
Computed - -
ME1_SHDA ME SHUTDOWN ACTIVE 1 - alarm 1 1 1 1.02
Computed 11 52
ME1_SHDC ME SHUTDOWN CANCELLED - - alarm 1 1 1 1.01
Computed 11 -
ME1_SHDP ME SHUTDOWN PREWARNING - - alarm 1 1 1 1.01
Computed 11 -
ME1_SHRA ME SHAFT RPM rpm -150.0 - - 1.02
Computed 150.0 - -
ME1_SLDA ME SLOWDOWN ACTIVE 2 - alarm 1 1 1 1.02
Computed 11 -
ME1_SLDC ME SLOWDOWN CANCELLED - - alarm 1 1 1 1.01
Computed 11 -
ME1_SLDN ME NON CANCELLABLE SLD ACTIVE 2 - alarm 1 1 1 1.01
Computed 11 -
ME1_SLDP ME SLOWDOWN PREWARNING - - alarm 1 1 1 1.01
Computed 11 -
ME1_SLF ME SLOWTURNING FAIL - - alarm 1 1 1 1.01
Computed 11 -
ME1_STOP ME STOPPED - - stopped 4 1 1 1.02
Computed - -
ME1_SUPR ME ALARM CUT-OUT IN STOP - - stopped 4 1 1 1.02
Computed - -

Lyngso Marine A/S 651299 Printed: 2005-6-11


Monitoring Channels Report Page
Limit Related Parameters 30 / 33
ID Name Unit
Delay
Type Yard ID Scaling Disp Range Alm Grp Mess. Text Prio On Off Limit Suppression Rev.
MESLD01 THR. BEAR TEMP HIGH 70 - slow down 1 0 0 1.02
Computed - -
MESLD02 CRANK. OIL MIST HIGH 2 - slow down 1 0 0 1.02
DI NO - -
MESLD03 J.C.W INLET PRES LOW 70 - slow down 1 0 0 1.02
Computed - -
MESLD04 J.C.W OUTLET TEMP HI 70 - slow down 1 0 0 1.02
Computed - -
MESLD05 L.O. INLET PRESS LOW 70 - slow down 1 0 0 1.02
Computed - -
MESLD06 L.O. INLET TEMP HIGH 70 - slow down 1 0 0 1.02
Computed - -
MESLD07 LUBRICATOR NO FLOW 70 - slow down 1 0 0 1.02
Computed - -
MESLD08 P.C.O OUTLET TEMP HI 70 - slow down 1 0 0 1.02
Computed - -
MESLD09 P.C.O OUTLET NO FLOW 70 - slow down 1 0 0 1.02
Computed - -
MESLD10 EXH GAS TEMP HIGH 70 - slow down 1 0 0 1.02
Computed - -
MESLD11 SCAV. AIR FIRE 70 - slow down 1 0 0 1.02
Computed - -
MESLD12 EXH VALVE AIR PRES L 70 - slow down 1 1 1 1.02
Computed - -
MESLD13 AXIAL VIBRATION HIGH 70 - slow down 1 0 0 1.02
Computed - -
MESLD14 ME EXH GAS DEV SLD 70 - slow down 1 0 0 1.02
Computed - -
MESTOP ME STOPPED - - on 4 1 1 1.02
Computed - -
MESTOP1 ME STOPPED - - on 4 1 1 1.02
Computed - -
NFWE ME NOT FWE - - on 4 0 0 1.02
Computed - -

Lyngso Marine A/S 651299 Printed: 2005-6-11


Monitoring Channels Report Page
Limit Related Parameters 31 / 33
ID Name Unit
Delay
Type Yard ID Scaling Disp Range Alm Grp Mess. Text Prio On Off Limit Suppression Rev.
OS1FAIL OUSTATION 1 POWER FAILURE 99 - normal 4 0 0 1.01
Computed - -
OS2FAIL OUSTATION 2 POWER FAILURE 99 - normal 4 0 0 1.01
Computed - -
PANEL01 PANEL NET TO ECR - 0 - - 1.01
Computed 15 - 99
PANEL02 PANEL NET TO BRIDGE - 0 - - 1.01
Computed 15 - 99
PANEL03 PANEL NET TO GYMNASIUM - 0 - - 1.01
Computed 15 - 99
PANEL04 PANEL NET TO S.C.C - 0 - - 1.01
Computed 15 - 99
PANEL05 PANEL NET TO DUTY MESS. - 0 - - 1.01
Computed 15 - 99
PANEL06 PANEL NET TO OFF. MESS. - 0 - - 1.01
Computed 15 - 99
PANEL07 PANEL NET TO OFF. SMOKE - 0 - - 1.01
Computed 15 - 99
PANEL08 PANEL NET TO 2ND OFF. - 0 - - 1.01
Computed 15 - 99
PANEL09 PANEL NET TO 1ST OFF. - 0 - - 1.01
Computed 15 - 99
PANEL10 PANEL NET TO 2ND ENG - 0 - - 1.01
Computed 15 - 99
PANEL11 PANEL NET TO 3RD ENG - 0 - - 1.01
Computed 15 - 99
PANEL12 PANEL NET TO C/ENG OFFICE - 0 - - 1.01
Computed 15 - 99
PANEL13 PANEL NET TO C/ENG DAY ROOM - 0 - - 1.01
Computed 15 - 99
PANEL14 PANEL NET TO 1ST ENG DAY RM - 0 - - 1.01
Computed 15 - 99
PANEL15 PANEL NET TO CHIEF OFF - 0 - - 1.02
Computed 15 - 99

Lyngso Marine A/S 651299 Printed: 2005-6-11


Monitoring Channels Report Page
Limit Related Parameters 32 / 33
ID Name Unit
Delay
Type Yard ID Scaling Disp Range Alm Grp Mess. Text Prio On Off Limit Suppression Rev.
PANEL16 PANEL NET TO CAPTAIN - 0 - - 1.02
Computed 15 - 99
PHONE_IN TELEPHONE - 32 alarm 1 5 1 1.01
DI NO - -
PRINT1 MASTER: PRINTER 1 - - print err 1 0 0 1.01
Computed - 99
PRINT2 MASTER: PRINTER 2 - - print err 1 0 0 1.01
Computed - 99
SN002001 GAMMA2:STL NET TO GAMMA 1 - 0 - - 1.01
Computed 15 - 99
SN002040 GAMMA2:STL NET TO GAMMA 40 - 0 - - 1.01
Computed 15 - 99
SN040002 GAMMA40:STL NET TO GAMMA 2 - 0 - - 1.02
Computed 15 - 99
STPHRN STOP HORN - - 4 1.01
DI NO - -
TACHO_11 TACHO_1 PICKUP 1 FAIL 11 - fail 1 3 3 1.02
Computed 5 -
TACHO_12 TACHO_1 PICKUP 2 FAIL 5 - fail 1 3 3 1.02
Computed 11 -
TGBCAS01 ME: BRG TLG AS: FULL rpm -100.0 - - active 4 2 1 -90.0 1.02
Computed 100.0 51 - -81.0
TGBCAS02 ME: BRG TLG AS: HALF rpm -100.0 - - active 4 2 1 -81.0 1.02
Computed 100.0 51 - -66.0
TGBCAS03 ME: BRG TLG AS: SLOW rpm -100.0 - - active 4 2 1 -66.0 1.02
Computed 100.0 51 - -46.0
TGBCAS04 ME: BRG TLG AS: DEADSLOW rpm -100.0 - - active 4 2 1 -46.0 1.02
Computed 100.0 51 - -35.0
TGBCAS05 ME: BRG TLG: STOP rpm -100.0 - - active 4 2 1 -20.0 1.02
Computed 100.0 51 - 20.0
TGBCAS06 ME: BRG TLG AH: DEADSLOW rpm -100.0 - - active 4 2 1 35.0 1.02
Computed 100.0 51 - 46.0
TGBCAS07 ME: BRG TLG AH: SLOW rpm -100.0 - - active 4 2 1 46.0 1.02
Computed 100.0 51 - 66.0

Lyngso Marine A/S 651299 Printed: 2005-6-11


Monitoring Channels Report Page
Limit Related Parameters 33 / 33
ID Name Unit
Delay
Type Yard ID Scaling Disp Range Alm Grp Mess. Text Prio On Off Limit Suppression Rev.
TGBCAS08 ME: BRG TLG AH: HALF rpm -100.0 - - active 4 2 1 66.0 1.02
Computed 100.0 51 - 86.0
TGBCAS09 ME: BRG TLG AH: FULL rpm -100.0 - - active 4 2 1 86.0 1.02
Computed 100.0 51 - 101.0
TGBCAS10 ME: BRG TLG AH: MAX FULL rpm -100.0 - - active 4 2 1 101.0 1.02
Computed 100.0 51 - 127.0
TGERAS01 ME: ECR TLG AS: FULL rpm -100.0 - - active 4 2 1 -90.0 1.02
Computed 100.0 51 - -81.0
TGERAS02 ME: ECR TLG AS: HALF rpm -100.0 - - active 4 2 1 -81.0 1.02
Computed 100.0 51 - -66.0
TGERAS03 ME: ECR TLG AS: SLOW rpm -100.0 - - active 4 2 1 -66.0 1.02
Computed 100.0 51 - -46.0
TGERAS04 ME: ECR TLG AS: DEADSLOW rpm -100.0 - - active 4 2 1 -46.0 1.02
Computed 100.0 51 - -35.0
TGERAS05 ME: ECR TLG: STOP rpm -100.0 - - active 4 2 1 -20.0 1.02
Computed 100.0 51 - 20.0
TGERAS06 ME: ECR TLG AH: DEADSLOW rpm -100.0 - - active 4 2 1 35.0 1.02
Computed 100.0 51 - 46.0
TGERAS07 ME: ECR TLG AH: SLOW rpm -100.0 - - active 4 2 1 46.0 1.02
Computed 100.0 51 - 66.0
TGERAS08 ME: ECR TLG AH: HALF rpm -100.0 - - active 4 2 1 66.0 1.02
Computed 100.0 51 - 86.0
TGERAS09 ME: ECR TLG AH: FULL rpm -100.0 - - active 4 2 1 86.0 1.02
Computed 100.0 51 - 101.0
TGERAS10 ME: ECR TLG AH: MAX FULL rpm -100.0 - - active 4 2 1 101.0 1.02
Computed 100.0 51 - 127.0
End of Report

Lyngso Marine A/S 651299 Printed: 2005-6-11

You might also like