CS Catalogo - Expansion Join Covers PDF
CS Catalogo - Expansion Join Covers PDF
CS Catalogo - Expansion Join Covers PDF
2013
City Center The Marina Bay Sands Columbia University City Creek Center
Architect: HKS Architect: Aedas & Moshe Interdisciplinary Center Architects: Hobbs & Black
Safdie Associates Architect: Rafael Moneo and Callison
Large seismic joints are necessary in todays architecture and unfortunately, they can destroy even the finest
C/S can make even the biggest joints disappear. interior and exterior designs. C/S has dedicated itself to becoming a master at hiding joints by developing a
range of covers that are virtually invisible in order to empathize with the architects design intent.
Interior and Exterior Joint Covers at Norman Y. Interior Joint Covers at John Wayne Airport
Mineta San Jose International Airport Terminal C, Orange County, CA
Gensler did not want its design for the San Jose Airport to The airports new terminal C is located in a seismic area that
be interrupted by obtrusive expansion joint covers inside or required massive 28" expansion joint covers. To prevent the joint
out. For the exterior, Gensler called on C/S to incorporate covers from ruining the buildings sleek design, Gensler specified
25" XLS covers within the 34" wide CENTRIA metal panels, the C/S LAF covers for the airports ceiling and customized XLS
making them disappear in the roof structure. interior covers for the walls.
5
4
T h e C / S d i f f erence
Exclusive cutting-edge
7
Whatever criteria your project calls And, only we can prove it works.
for, C/S can create a cover to meet it. See a full scale test in our exclusive test facility.
C/S has been helping architects solve complex building movement problems
for over 45 years. Since every project has its own special movement criteria,
one of C/S standard designs may not be right for your project. A large
percentage of our projects require custom expansion joint covers.
C/S team of technical experts can design a custom cover to meet your
projects specific requirements. And with the industrys
only full scale expansion joint test chamber, we can
show you in person that your expansion joint cover
will function as designed and will work under real-
life conditions. Our test chamber is capable of
testing the industrys largest joint covers.
Testing
Testing Testing two-way multi-directional
Lateral Shear movement movement
The chamber can The chamber can C/S Joint covers can
test joint covers cycle the joint cover be tested for four-way
for lateral shear. for expansion and movement and vertical
contraction. displacement.
C/S Pricing is all inclusive.
Dont be fooled by competitors low-ball prices!
5 S pecialized equipment to
help with installation. n Hardware
Cover Type Flush Thinline Flush Twinline Flush Seismic, Standard Seismic Seismic Flush Thinline Flush Twinline Seismic Flush Allway Metal Exterior Wall Roof Parking &
Gasketed Dual Gasketed Seismic PAN Allway Metal Allway Metal Corridor Cover Gasketed Dual Gasketed Twinline Stadiums
Appearance
Joint Size
1" and 2" 2" to 4" 2" and up 1" to 4" 2" and up 12" to 36" 1" to 10" 2" and up 4" and up 1" to 4" 2" and up 2" and up 1" to 16"
Description Minimum exposed Minimum exposed Minimum exposed Robust Robust Corridors in Minimum exposed Minimum exposed Minimum exposed Robust Minimum exposed Formed aluminum Exterior, waterproof
surface, sealed dual surface, sealed dual surface, optional applications, applications, base isolated surface, sealed surface, sealed surface, optional applications, low surface, sealed and EPDM bellows applications, full
durometer gasket durometer gasket sealed gasket low maintenance low maintenance, structures with gasket installation gasket installation, sealed gasket maintenance, full gasket installation, options, full movement range
installation installation, larger installation, seismic seismic movement multi-directional larger movement installation, seismic movement range full movement movement range
movement movement movement movement range
Finishes
Carpet, vinyl, Carpet, vinyl Carpet, vinyl, Concrete, carpet, Concrete, pavers, Carpet, vinyl Drywall, Drywall, Drywall, panel All finishes All finishes All roof finishes Concrete, paver
ceramic tile, terrazzo, stone vinyl carpet, vinyl, ceramic tile ceramic tile systems, metal
terrazzo, stone ceramic tile cladding, stone
Designed For
Hygienic, Hygienic, Hygienic, wheeled Industrial, Industrial, Commercial Hygienic, Hygienic, All commercial and Industrial, matches All exteriors, All roofs Vehicular traffic,
wheeled wheeled equipment, deep heavy wheeled heavy wheeled and healthcare matches Thinline matches Twinline healthcare interiors Allway floor covers colorable stadium seating
equipment equipment floor finish materials, equipment equipment, also interiors floor covers floor covers bowls and
also exterior exterior concourse
% Movement +/-
50% of 100% of 100-200% of 100-200% of 100-200% of 100-200% of 50-200% of 100-200% of 100-200% of 100-200% of 100-200% of 100-200% of 50-200% of
Joint Width Joint Width Joint Width Joint Width Joint Width Joint Width Joint Width Joint Width Joint Width Joint Width Joint Width Joint Width Joint Width
Page #
14-15 16-17 18-21 22-23 24-25 26-27 28-29 30-31 30-31 32-33 34-37 38-39 40-41
Matching Floor
N/A N/A N/A N/A N/A N/A 14-15 16-17 18-21 22-23 N/A N/A N/A
Wall/Ceiling
28-29 30-31 30-31 32-33 30-31 26-27 N/A N/A N/A N/A N/A N/A N/A
Fire Barriers
Reflex Reflex Multiflex Reflex Multiflex FB-97 Reflex Reflex Multiflex Reflex Contact Contact Contact
Page 43 or Multiflex or FB-97 Page 43 Page 43 Page 43 or Multiflex or Multiflex or FB-97 or Multiflex Factory Factory Factory
Page 43 Page 43 Page 43 Page 43 Page 43 Page 43
Cost Index
65 105 125 100 100 N/A 55 180 N/A 100 150 N/A N/A
All C/S Expansion Joint Covers, Seals and Processes are ISO 9001: 2000 compliant. All C/S Expansion Joint Covers feature a 5 year limited warranty. 100 By assigning our metal systems a cost of 100, you can determine how much an alternate system of similar size will cost. 13
12
All models below are available for purchase online. Go to www.c-sgroup.com/buyejc
GFT ES GFST ES
Flush gasketed covers for small interior joints where minimal visual
impact is preferred. Perfect for wheeled equipment. ADA compliant.
1"-3"
JW JW
GFPS GFS
ES ES
JW JW
Minimum Opening 0.75" 1.50" 0.75" 1.50" 0.75" 1.50" 0.75" 1.50"
Maximum Opening 1.25" 2.50" 1.25" 2.50" 1.25" 2.50" 1.25" 2.50"
Exposed Surface 1.25" 1.88" 1.18" 1.88" 4.31" 5.13" 4.31" 5.13"
Specify Model GFT 100 GFT 200 GFPS 100 GFPS 200 GFS 100 GFS 200 GFST 100 GFST 200
Joint Width 1" 2" 1" 2" 1" 2" 1" 2"
Minimum Opening 0.75" 1.50" 0.75" 1.50" 0.75" 1.50" 0.75" 1.50"
Maximum Opening 1.25" 2.50" 1.25" 2.50" 1.25" 2.50" 1.25" 2.50"
Exposed Surface 1.12" 1.88" 1.18" 1.88" 2.63" 3.56" 2.63" 3.56"
Specify Model GFTW 100 GFTW 200 GFPSW 100 GFPSW 200 GFSW 100 GFSW 200 GFSTW 100 GFSTW 200 15
For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com
For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers
5/8"
1-3/16"
JW JW
5/8" 5/8"
Minimum Opening 1.25" 1.25" 2.25" 1.25" 1.25" 1.25" 1.25" 1.25" 1.25"
Recessed cover Maximum Opening 3.75" 6.00" 6.25" 3.75" 6.00" 6.25" 3.75" 6.00" 6.25"
plate accepts 1/8" or Exposed Surface 6.50" 10.00" 11.00" 6.50" 10.00" 11.00" 6.50" 10.00" 11.00"
3/8" carpet and tile to
Specify Model GTR 200 GTR 300 GTR 400 DGTR 200 DGTR 300 DGTR 400 GTP 200 GTP 300 GTP 400
conceal the cover in
the surrounding floor FLOOR TO WALL COVERS
Joint Width 2" 3" 4" 2" 3" 4" 2" 3" 4"
Minimum Opening 1.00" 1.50" 2.50" 1.00" 1.50" 2.50" 1.00" 1.50" 2.50"
Maximum Opening 3.00" 4.50" 5.50" 3.00" 4.50" 5.50" 3.00" 4.50" 5.50"
Exposed Surface 4.25" 6.50" 7.50" 4.25" 6.50" 7.50" 4.25" 6.50" 7.50"
Specify Model GTRW 200 GTRW 300 GTRW 400 DGTRW 200 DGTRW 300 DGTRW 400 GTPW 200 GTPW 300 GTPW 400
17
For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers
3/4" 3/4"
JW JW
3/4" 3/4"
Gasket available in
4 standard and any
custom color to
match surrounding JW JW
floor finishes
MODEL DATA
FLOOR TO FLOOR COVERS
Joint Width 5" 6" 7" 8" 9" 10" 11" 12" 13" 14" 15" 16"
Minimum Opening 2.50" 2.75" 2.75" 2.75" 2.75" 2.75" 2.75" 2.75" 2.75" 2.75" 2.75" 2.75"
Maximum Opening 9.25" 9.50" 12.25" 13.25" 14.25" 16.25" 18.25" 18.50" 21.25" 22.25" 23.00" 25.25"
Exposed Surface 12.00" 13.00" 15.00" 16.00" 18.00" 19.00" 21.00" 22.00" 24.00" 25.00" 27.00" 28.00"
5" to 16" joint covers Specify Model SGR 500 SGR 600 SGR 700 SGR 800 SGR 900 SGR 1000 SGR 1100 SGR 1200 SGR 1300 SGR 1400 SGR 1500 SGR 1600
to accommodates
Plate deflectors large seismic joints FLOOR TO WALL COVERS
disengage gaskets Joint Width 5" 6" 7" 8" 9" 10" 11" 12" 13" 14" 15" 16"
during seismic Minimum Opening 4.25" 4.25" 5.00" 5.50" 6.00" 6.50" 7.00" 7.50" 8.00" 8.50" 9.00" 9.50"
activity to provide Maximum Opening 7.75" 7.75" 9.50" 10.50" 11.50" 13.00" 14.50" 15.25" 17.00" 18.00" 19.00" 20.50"
additional movement Exposed Surface 8.50" 9.50" 11.00" 12.00" 13.50" 14.50" 16.00" 17.00" 18.50" 19.50" 21.00" 22.00"
Specify Model SGRW 500 SGRW 600 SGRW 700 SGRW 800 SGRW 900 SGRW 1000 SGRW 1100 SGRW 1200 SGRW 1300 SGRW 1400 SGRW 1500 SGRW 1600
SGR and SGP have same model data. SGRW and SGPW have same model data. For larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com
19
For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers
2" 2"
JW JW
Exclusive edge
protection eliminates
chipping of pavers
SSR-500-700 SSR-800+
ES ES
JW JW
MODEL DATA
Floor to Floor Covers
Joint Width 2" 4" 6" 8" 10" 12" 14" 16"
Minimum Opening 0.75" 0.75" 0.75" 2.25" 2.25" 2.25" 2.25" 2.25"
Maximum Opening 4.00" 6.00" 9.50" 13.00" 16.00" 19.00" 22.00" 25.00"
Exposed Surface 13.81" 13.81" 17.75" 20.75" 23.75" 26.75" 29.75" 32.75"
Specify Model SSR 200 SSR 400 SSR 600 SSR 800 SSR 1000 SSR 1200 SSR 1400 SSR 1600
Gravity activated
turnbar raises and Floor to Wall Covers
lowers cover during Joint Width 2" 4" 6" 8" 10" 12" 14" 16"
seismic activity Minimum Opening 1.00" 1.00" 1.00" 3.00" 3.00" 3.00" 3.00" 3.00"
The thickness Maximum Opening 6.00" 6.00" 12.00" 10.50" 13.00" 15.50" 18.00" 20.50"
of the modular Exposed Surface 9.25" 9.25" 15.25" 14.38" 16.88" 19.38" 21.88" 24.32"
pan eliminates Specify Model SSRW 200 SSRW 400 SSRW 600 SSRW 800 SSRW 1000 SSRW 1200 SSRW 1400 SSRW 1600
flooring deflection For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com
and cracking 21
Select models are available for purchase online. Go to www.c-sgroup.com/buyejc
JW JW
ES ES
1" 1"
JW JW
Gaskets to eliminate
noise and metal to
metal contact
MODEL DATA
FLOOR TO FLOOR COVERS
Joint Width 1" 2" 3" 4" 2" 4" 2" 4" 2" 4"
Minimum Opening 0.75" 1.63" 2.50" 3.25" 0.00" 0.88" 0.00" 0.88" 0.00" 0.00"
Maximum Opening 1.25" 2.38" 3.50" 4.75" 4.00" 7.00" 4.00" 7.00" 3.75" 6.75"
Free-floating Exposed Surface 1.70" 3.30" 4.37" 5.28" 3.65" 6.44" 7.75" 11.75" 5.25" 8.25"
aluminum center slides Specify Model APF 100 APF 200 APF 300 APF 400 ALR 200 ALR 400 ALS 200 ALS 400 PC 200 PC 400
between cover frames
FLOOR TO WALL COVERS
to provide movement
Joint Width 1" 2" 3" 4" 2" 4" 2" 4" 2" 4"
Minimum Opening 0.75" 1.63" 2.50" 3.25" 1.00" 2.44" 1.00" 2.44" 0.00" 0.00"
Frame heights Maximum Opening 1.25" 2.38" 3.50" 4.75" 3.00" 5.50" 3.00" 5.50" 3.75" 6.75"
available for different Exposed Surface 1.70" 3.30" 4.37" 5.28" 2.81" 5.19" 4.88" 7.88" 3.75" 6.75"
floor finishes Specify Model APFW 100 APFW 200 APFW 300 APFW 400 ALRW 200 ALRW 400 ALSW 200 ALSW 400 PCW 200 PCW 400
Excellent choice for For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com
Transit applications Note: All joint systems on this page are available for 1"-4" joints. Contact factory if required size is not listed.
23
For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers
1-1/8" 1-1/2"
Flush finish
JW JW
Heavy-duty model
SJPFM SJHD
can accommodate Heavy Duty 2,000 lb. Point Load
2000 lb. point loads ES ES
1-1/8" 1-3/8"
JW JW
MODEL DATA
FLOOR TO FLOOR COVERS
Joint Width 4" 6" 8" 2" 4" 6" 2" 4" 6" 8" 10" 12" 14" 16"
Minimum Opening 2.75" 2.75" 2.75" 1.00" 1.00" 1.00" 1.00" 1.00" 1.00" 1.00" 1.00" 1.00" 1.00" 1.00"
Maximum Opening 6.38" 9.25" 14.13" 4.00" 6.50" 9.88" 4.50" 7.50" 11.13" 14.25" 16.75" 21.00" 23.75" 24.25"
Exposed Surface 8.75" 11.75" 14.75" 5.00" 8.00" 11.50" 3.50" 7.50" 11.88" 15.00" 17.94" 21.00" 23.88" 27.00"
Plate is available in a Specify Model SJ-HD 400 SJ-HD 600 SJ-HD 800 SJPF 200 SJPF 400 SJPF 600 SJP 200 SJP 400 SJP 600 SJP 800 SJP 1000 SJP 1200 SJP 1400 SJP 1600
variety of finishes
FLOOR TO WALL COVERS
During seismic activity Joint Width 4" 6" 8" 2" 4" 6" 2" 4" 6" 8" 10" 12" 14" 16"
self-centering cover Minimum Opening 3.38" 4.38" 5.38" 0.00" 0.00" 0.00" 0.00" 0.00" 0.00" 4.50" 5.50" 6.50" 7.50" 8.50"
plate disengages Maximum Opening 5.19" 7.63" 11.06" 3.00" 5.25" 7.94" 3.25" 5.75" 8.50" 10.00" 13.31" 16.50" 18.75" 20.00"
Exposed Surface 6.38" 8.88" 11.38" 3.75" 6.00" 8.75" 3.25" 5.75" 9.00" 11.50" 14.00" 16.50" 19.00" 21.50"
Specify Model SJW-HD 400 SJW-HD 600 SJW-HD 800 SJPFW 200 SJPFW 400 SJPFW 600 SJPW 200 SJPW 400 SJPW 600 SJPW 800 SJPW 1000 SJPW 1200 SJPW 1400 SJPW 1600
For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com
25
For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers
structures. It is perfect where egress is necessary during an earthquake. integrated assembly approach with floor, wall and
ceiling covers connected and moving in unison. This
Gyrometric System, or cab assembly, provides full
movement of up to 200% in any horizontal direction.
The floor cover may be used independently of the wall
and ceiling covers for lineal applications where lateral
shear is a problem (specify model XYZ).
Full Open (During Tension) During an event in the expansion
or tension mode the cab slides fully out.
COVER DETAILS
Floor/Wall Section
de Young Museum, CA 27
26
Select models are available for purchase online. Go to www.c-sgroup.com/buyejc
FWF JW FCF JW
These flush gasketed wall and ceiling covers are designed to align
with our flush gasketed floor covers. These covers are suitable for
most wall and ceiling finishes and are completely unobtrusive.
ES
ES
JW JW
FWS FCS
ES ES
Santoprene gaskets
integrate with most wall ES ES
and ceiling surfaces
Minimum Opening 0.56" 0.56" 1.00" 1.00" 1.00" 1.00" 1.00" 0.56" 0.56" 1.00" 1.00" 1.00" 1.00" 1.00"
Maximum Opening 1.25" 2.50" 4.50" 6.00" 4.00" 6.00" 8.00" 1.25" 2.50" 4.50" 6.00" 4.00" 6.00" 8.00
Exposed Surface 1.06" 2.06" 3.00" 4.00" 2.00" 3.00" 4.00" 0.81" 1.63" 3.00" 4.00" 2.00" 3.00" 4.00"
Specify Model FWF 100 FWF 200 FWF 300 FWF 400 FWS 200 FWS 300 FWS 400 FCF 100 FCF 200 FCF 300 FCF 400 FCS 200 FCS 300 FCS 400
Minimum Opening 0.75" .75" 1.00" 1.00" 1.00" 1.00" 1.00" 0.75" 0.75" 1.00" 1.00" 1.00" 1.00" 1.00"
Maximum Opening 1.25" 2.50" 4.50" 6.00" 4.00" 6.00" 8.00" 1.25" 2.50" 4.50" 6.00" 4.00" 6.00" 8.00"
Exposed Surface 0.88" 2.00" 3.00" 4.00" 2.00" 3.00" 4.00" 1.00" 1.75" 3.00" 4.00" 2.00" 3.00" 4.00"
Specify Model FWFC 100 FWFC 200 FWFC 300 FWFC 400 FWSC 200 FWSC 300 FWSC 400 FCFC 100 FCFC 200 FCFC 300 FCFC 400 FCSC 200 FCSC 300 FCSC 400 29
For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com
For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers
ES ES
Aluminum Panel
GTW SGC
deflector
JW
JW
Lightweight Panel is Joint Width 2" 4" 6" 8" 10" 12" 14" 16" 4" 6" 8" 10" 12" 14" 16"
designed to disengage Minimum Opening 1.25" 1.25" 2.75" 2.75" 2.75" 2.75" 2.75" 2.75" 1.00" 1.00" 1.00" 1.00" 1.00" 1.00" 1.00"
from the wall during a Maximum Opening 3.75" 6.25" 9.25" 12.75" 15.75" 18.75" 21.75" 24.75" 8.00" 12.00" 16.00" 20.00" 24.00" 28.00" 32.00"
seismic event so it doesnt Exposed Surface 6.50" 11.00" 13.00" 16.00" 19.00" 22.00" 25.00" 28.00" 14.31" 16.31" 18.31" 20.31" 22.31" 24.31" 26.31"
damage surrounding Specify Model GTW 200 GTW 400 SGW 600 SGW 800 SGW 1000 SGW 1200 SGW 1400 SGW 1600 LAF 400 LAF 600 LAF 800 LAF 1000 LAF 1200 LAF 1400 LAF 1600
wall surfaces
CORNER WALL COVERS
Joint Width 2" 4" 6" 8" 10" 12" 14" 16" 4" 6" 8" 10" 12" 14" 16"
Minimum Opening 1.00" 2.50" 4.25" 5.50" 6.50" 7.50" 8.50" 9.50" 2.00" 2.00" 2.00" 2.00" 2.00" 2.00" 2.00"
Maximum Opening 3.00" 5.50" 7.50" 10.25" 12.75" 15.25" 17.75" 20.25" 8.00" 12.00" 16.00" 20.00" 24.00" 28.00" 32.00"
Exposed Surface 4.25" 7.50" 9.50" 12.00" 14.50" 17.00" 19.50" 22.00" 9.13" 11.13" 13.13" 15.13" 17.13" 19.13" 21.13"
Specify Model GTWC 200 GTWC 400 SGWC 600 SGWC 800 SGWC 1000 SGWC 1200 SGWC 1400 SGWC 1600 LAFC 400 LAFC 600 LAFC 800 LAFC 1000 LAFC 1200 LAFC 1400 LAFC 1600
For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com
31
Select models are available for purchase online. Go to www.c-sgroup.com/buyejc
JW JW
ES ES
SFW SFC
JW
JW
Minimum Opening 0.25" 0.38" 0.00" 1.00" 0.38" 0.38" 0.38" 0.38" 2.75" 2.75" 2.75" 2.75"
Variety of
finishes available Maximum Opening 1.88" 3.50" 6.38 7.38" 1.50" 3.00" 6.00" 6.00" 7.25" 14.75" 18.50" 26.00"
Exposed Surface 5.00" 7.75" 10.75" 11.75" 3.13" 4.63" 7.63" 7.63" 7.50" 15.00" 21.00" 27.00"
Specify Model AFW 100 AFW 200 AFW 300 AFW 400 ASM 100 ASM 200 ASM 300 ASM 400 SFW 400 SFW 800 SFW 1200 SFW 1600
Minimum Opening 0.63" 1.19" 1.50" 2.50" 0.50" 0.50" 0.50" 0.50" 0.00" 5.50" 7.50" 9.50"
Maximum Opening 1.44" 2.75" 4.69" 5.69" 1.50" 3.00" 6.00" 6.00" 5.50" 11.25" 15.25" 21.00"
Exposed Surface 2.37" 4.25" 6.25" 7.25" 1.88" 3.38" 6.38" 6.38" 5.75" 11.50" 16.25" 21.50"
Specify Model AFWC 100 AFWC 200 AFWC 300 AFWC 400 ASMC 100 ASMC 200 ASMC 300 ASMC 400 SCW 400 SCW 800 SCW 1200 SCW 1600
For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com.
Note: additional wall and ceiling cover models SFW and SFC available, go towww.c-sgroup.com.
33
Select models are available for purchase online. Go to www.c-sgroup.com/buyejc
ES ES
SF-1200 VF
JW
JW
Durable, watertight
system for all
exterior applications
ES ES
High quality
gaskets available MODEL VF Colors Precast White Gray Limestone Sandstone Natural Stone Dusty Rose
in two styles
Adobe Tan
2" to 36" covers provide Rustic Brick Blue Spruce Bronze Charcoal Black
multi-directional
movement
Gasket Colors Black White Gray Greige
Note: Custom colors available. Call 800-233-8493.
MODEL DATA
EXTERIOR WALL COVERS
Joint Width 2" 3" 4" 5" 6" 7" 8" 9" 10" 12" 14" 16" 1.0" 2.0" 3.0" 4.0" 6.0" 8.0"
Minimum Opening 1.25" 1.25" 1.25" 1.25" 1.75" 2.50" 2.50" 2.50" 2.50" 6.00" 6.00" 6.00" 0.50" 1.00" 1.50" 2.00" 3.00" 4.00"
Maximum Opening 3.00" 4.50" 6.00" 7.50" 9.00" 10.50" 12.00" 13.50" 15.00" 18.00" 21.00" 24.00" 1.50" 3.00" 4.50" 6.00" 9.00" 12.00"
Exposed Surface
Custom colorable 2.00" 3.00" 4.00" 5.00" 6.00" 7.00" 8.00" 9.00" 10.00" 12.00" 14.00" 16.00" 1.00" 2.00" 3.00" 4.00" 6.00" 8.00"
Specify Model SF 200 SF 300 SF 400 SF 500 SF 600 SF 700 SF 800 SF 900 SF 1000 SF 1200 SF 1400 SF 1600 VF 100 VF 200 VF 300 VF 400 VF 600 VF 800
Maximum Opening 8.00" 10.00" 12.00" 14.00" 16.00" 18.00" 20.00" 22.00" 24.00" 26.00" 28.00" 30.00" 32.00"
Exposed Surface 4.00" 5.00" 6.00" 7.00" 8.00" 9.00" 10.00" 11.00" 12.00" 13.00" 14.00" 15.00" 16.00"
Specify Model SC 400 SC 500 SC 600 SC 700 SC 800 SC 900 SC 1000 SC 1100 SC 1200 SC 1300 SC 1400 SC 1500 SC 1600
For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com
35
For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers
XLS ESW
JW JW
Cover releases from Magnet
the wall on one Strike Plate
side to provide full
seismic movement
Door is self-closing
(utilizing weights and
pulleys) after an event
ES ES
Minimum Opening 4.00" 4.00" 4.00" 4.00" 4.00" 2.50" 2.50" 2.50" 2.50"
Maximum Opening 16.00" 20.00" 24.00" 28.00" 32.00" 6.00" 13.00" 19.00" 25.00"
Exposed Surface 17.31" 19.31" 21.31" 23.31" 25.31" 12.00" 18.00" 24.00" 30.00"
Specify Model XLS 800 XLS 1000 XLS 1200 XLS 1400 XLS 1600 ESW 400 ESW 800 ESW 1200 ESW 1600
Minimum Opening 4.00" 4.00" 4.00" 4.00" 4.00" 3.25" 5.25" 7.25" 8.75"
Maximum Opening 16.00" 20.00" 24.00" 28.00" 32.00" 6.50" 10.50" 15.50" 20.50"
Exposed Surface 13.00" 15.00" 17.00" 19.00" 21.00" 8.00" 13.00" 18.00" 23.00"
Specify Model XLSC 800 XLSC 1000 XLSC 1200 XLSC 1400 XLSC 1600 ESC 400 ESC 800 ESC 1200 ESC 1600
For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com
37
Select models are available for purchase online. Go to www.c-sgroup.com/buyejc
multi-directional movement. ES
JW
Variety of
finishes available
RJT BRJ
ES
JW JW Secondary Seal
(Optional)
the sliding metal cover Minimum Opening 0.00" 0.00" 0.00" 0.00" 0.00" 0.00" 0.00" 0.00" 1.00" 1.00" 1.00" 1.00" 1.00" 1.00" 1.00"
Maximum Opening 3.00" 6.00" 9.00" 12.00" 15.00" 18.00" 21.00" 24.00" 7.50" 11.75" 12.50" 16.75" 20.75" 21.00 24.25"
Factory fabricated Exposed Surface N/A N/A N/A N/A N/A N/A N/A N/A 12.00" 15.00" 18.00" 21.00" 24.00" 27.00" 30.00"
transitions to meet all Specify Model BRJ 200 BRJ 400 BRJ 600 BRJ 800 BRJ 1000 BRJ 1200 BRJ 1400 BRJ 1600 SRJ 400 SRJ 600 SRJ 800 SRJ 1000 SRJ 1200 SRJ 1400 SRJ 1600
roof/parapet conditions
Waterstop ROOF TO WALL COVERS
Joint Width 2" 4" 6" 8" 10" 12" 14" 16" 4" 6" 8" 10" 12" 14" 16"
Minimum Opening 0.00" 0.00" 0.00" 0.00" 0.00" 0.00" 0.00" 0.00" 0.00" 0.00" 4.50" 5.50" 6.50" 7.50" 8.50"
Maximum Opening 3.00" 6.00" 9.00" 12.00" 15.00" 18.00" 21.00" 24.00" 6.25" 8.75" 10.25" 13.25" 16.25" 17.50" 20.00"
Exposed Surface N/A N/A N/A N/A N/A N/A N/A N/A 8.00" 10.50" 13.00" 15.50" 18.00" 20.50" 23.00"
Specify Model BRJW 200 BRJW 400 BRJW 600 BRJW 800 BRJW 1000 BRJW 1200 BRJW 1400 BRJW 1600 SRJW 400 SRJW 600 SRJW 800 SRJW 1000 SRJW 1200 SRJW 1400 SRJW 1600
For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com
39
Select models are available for purchase online. Go to www.c-sgroup.com/buyejc
ZB ZBSM
C/S parking joints are designed to eliminate problems associated with ES
ES
standard parking joints. C/S Zip Block seals install quickly without messy
elastomeric concrete. C/S KB and PTC Metal covers can handle constant
rolling loads without breaking or loosening.
JW
JW
KB PTC
ES ES
PDS HB
ES ES
JW JW
Minimum Opening 2.00" 2.00" 3.00" 0.00" 0.00" 0.00" 0.00" 0.00" 0.0" 3.00" 4.00" 5.50"
Installs quickly with Maximum Opening 6.50" 9.50" 12.50" 11.00" 13.00" 16.00" 19.00" 22.00" 25.0" 5.25" 7.75" 10.25"
epoxy, to eliminate messy Exposed Surface 11.25" 16.25" 20.25" 19.63" 21.63" 24.63" 27.38" 30.38" 33.38" 7.63" 11.13" 14.13"
elastomeric concrete Specify Model KB 400 KB 600 KB 800 PTC 600 PTC 800 PTC 1000 PTC 1200 PTC 1400 PTC 1600 KBW 400 KBW 600 KBW 800
Minimum Opening 0.50" 1.00" 1.50" 2.00" 0.50" 1.00" 1.50" 2.00" 0.75" 0.75" 1.50" 1.50"
Maximum Opening 1.50" 3.00" 4.50" 6.00" 1.50" 3.00" 4.50" 6.00" 3.25" 3.25" 6.50" 6.50"
Exposed Surface 8.00" 9.00" 10.00" 11.00" 1.00" 2.00" 3.00" 4.00" 4.75" 4.75" 6.75" 6.75"
Specify Model ZB 100 ZB 200 ZB 300 ZB 400 HB 100 HB 200 HB 300 HB 400 PDA-100 PDA-200 PDA-300 PDA-400
For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com
41
Select models are available for purchase online. Go to www.c-sgroup.com/buyejc
structure, it is necessary to maintain the fire integrity of that structure. Nominal C/S Model C/S Model C/S Model
Joint Width Floors Gypsum Wall Masonry Wall
1 RFX-1F RFX-1W (GYP.) RFX-1W (CONC)
RFX-1F RFX-1W (1 HR CONC)
2 RFX-2F RFX-2W (GYP.) RFX-2W (CONC)
Maintaining the integrity of a 2" wide joint is quite simple; require fire barriers to limit the passing of heat and flame for
RFX-2F RFX-2W (1 HR GYP.) RFX-2W (1 HR CONC)
however, a joint designed for seismic movement up to 2, 3 and sometimes 4 hours, as well as accommodating the 3 RFX-3F
24 inches becomes a more difficult proposition. In general, dynamic movement for which the joint was designed. ASTM E 4 RFX-4F
the wider the joint, the more complex the fire barrier. 1966 and UL 2079 specify criteria for cycling a fire barrier
C/S has simplified our fire barrier for small joint sizes 500 times prior to fire testing.
for easy installation and to maximize cost effectiveness
(see Reflex). Floor applications are relatively simple MONOFLEX (OFX) 3"-20" & Multiflex (MFX) 3"-12"
configurations regardless of joint size unless lateral shear UL Testing
C/S tests all of its fire barriers Sandwich assembly of layers of stainless steel foil and insulation
is required. Walls can be more complex. Variations in
at Underwriters Laboratories contained in a stainless steel mesh. Multiflex should be used where
wall configurations and transitions between adjacent (UL) because they represent lateral shear is required in floor applications having a 3"-12" joint width.
fire barriers make it critical to consult the manufacturer. the most stringent and
universally accepted testing
C/S has a technical expert available to assist you in authority including UL 2079
detailing these applications. Current building codes Cycling Tests.
Nominal C/S Model C/S Model C/S Model
Joint Width Floors Gypsum Wall Masonry Wall
3-20 OFX-3F-20F OFX-3W-20W (GYP) OFX-3W-20W (CONC)
3-12 MFX-3F-12F OFX-3W-12W (GYP) OFX-3W-12W (CONC)
FB97 13"-Up
LS designation indicates a special adaptation of the floor fire barrier to accommodate lateral shear
movement. FB-97 wall fire barriers naturally provide lateral shear movement.
43
6696 State Route 405, Muncy, Pennsylvania 17756 U.S.A., 570-546-5941
895 Lakefront Promenade, Mississauga, Ontario L5E 2C2 Canada, 905-274-3611
www.c-sgroup.com
For the nearest C/S representative, or literature and samples, call toll free
800-233-8493 in U.S.A. and 888-895-8955 in Canada, or visit www.c-sgroup.com