IQ4E CPU Controller
IQ4E CPU Controller
IQ4E CPU Controller
IQ4E/..
Controller
IQ4E Controller
Description Features
The IQ 4E controller has 10 universal inputs and 6 analogue 16 onboard I/O channels - 10 inputs and 6 outputs
voltage outputs and is expandable up to 192 points (depending I/O bus supports up to a total of 192 I/O channels (depending
on the controller variant) by adding I/O modules. This flexibility on the controller variant) using additional I/O modules
makes it suitable for a broad range of applications. I/O bus length up to 300 m (328 yards)
Ethernet 10/100 Mbps main network with TCP/IP protocol
The IQ4E controller uses Ethernet and TCP/IP networking Trend current loop LAN option
technologies with embedded XML and is fully compatible with Embedded XML Web Services as standard
other Trend IQ controllers. The IQ4E supports BACnet over IP BACnet over IP
as standard. Trend communications over a current loop LAN is Wallbus for connection of room displays
available as an option. A local PC or display (e.g. IQView4) can RS232 and USB local supervisor/engineering ports
be connected to the RS232 port. A Wallbus port is also provided Automatic time synchronisation and daylight saving via SNTP
for use with room displays. DIN rail mounting, DIN 19 size 2 standard enclosure
230 Vac, 24 Vac or 48 Vdc input power supply options
Physical
General 58.5 mm (2.3)
USB Connector Service Input Channel
(local engineering port) Indicators Button Indicators 53.5 mm (2.11)
116 mm (4.57)
110 mm (4.33)
DIN rail
clips
192.5 mm (7.55)
OK RX TX RX Output Channel
Ethernet Indicators Current Loop Indicators Indicators
(/LAN variants only)
Physical(continued)
Terminal Labels
Upper Labels
IQ4E/../230
Power Input Wallbus Universal Inputs
IQ4E/../24VAC
Power Input Wallbus Universal Inputs
1 2 3 80 81 70 71 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
!
All terminals 24V 24V
24V Class 2 (UL) 1 2 3 4 5 6 7 8 9 10
48V WMB AUX C C C C C C C C C C
Lower Label
IQ4E/../230 and IQ4E/../24VAC
Auxiliary Supply Output
Not used Ethernet Current Loop (/LAN variants only) Analogue Outputs
Functionality
The IQ4Es functionality can be divided into four sections: System, Hardware, Firmware, and Strategy.
System
The IQ4E has communication ports for Ethernet, USB (Local In addition, the IQ4E has the ability to join an internetwork
Engineering), RS232 (Local Supervisor) and Wallbus. In using its virtual INC (see Networking on page 4 for further
addition /LAN variants have a Trend current loop: details).
vINC
Ethernet
LAN Internetwork
In order to join an internetwork, an INC type device will be Inputs and Outputs
required elsewhere on the current loop LAN.
The IQ4E has 10 universal inputs and 6 analogue outputs, plus
The current loop may be wired in either a 2-wire or 4-wire three 24 Vdc auxiliary supply output terminals for powering
configuration. certain types of I/O devices. See Hardware on page 4 for
further details.
Network Bypass Relay:If the IQ4E loses power a set of
bypass relays will close to maintain the integrity of the current Cable Screening
loop network. If the relays close it will be recognised by a The use of screened cable for input and/or output connections
downstream device, and reported as a LAN Changed alarm. is not generally required unless the cable passes through
electrically noisy environments.
Baud Rate:By default the IQ4E auto-detects the baud rate to
use on the current loop. Where required, the rate can be set If screened cable is used the screen must be connected to the
manually using configuration software. local panel/enclosure ground and left unterminated at the far end.
When not in use the connector is protected by a retained flexible The following I/O module ranges are compatible with the IQ4E:
plastic plug.
IQ4/IO see IQ4/IO Modules Data Sheet (TA201341).
Wallbus XCITE/IO see XCITE/IO Modules Data Sheet (TA201352).
The Wallbus port facilitates the connection of room display Up to 30 modules can be connected to the I/O bus, depending
devices (e.g. an RD-WMB series room display). Devices can be on the module range(s) used and the number of I/O channels
wired using either bus (daisy-chain) or star topology. supported by the controller (as described above).
These devices offer control and indication of parameters such Module Range IQ4/IO only IQ4/IO and/or XCITE/IO
as setpoint, fan speed and occupancy, as well as sensing
Number of Modules 30 15
temperature, humidity and CO2 levels.
The last module on the I/O bus must be fitted with a terminator.
A suitable terminator (compatible with IQ4/IO modules only) is
supplied with the IQ4E.
Networking Hardware
In order to connect to the Trend network the IQ4E will create its Universal Inputs(IN1 to IN10)
own internal LAN which includes the following nodes:
Each input channel will function as one of the following:
a CNC for its own controller,
a supervisor CNC (sCNC1) for its RS232 port, thermistor input,
a supervisor CNC (sCNC2) for its USB port, voltage input,
three virtual CNCs (vCNC1, vCNC2 and vCNC3), and digital input, or
a virtual INC (vINC). current input.
Supervisor Web Supervisor The input function is set automatically by the IQ4E strategy.
/Tool Browser /Tool IQSET
Thermistor input:Used for a thermistor (NTC 10 k @ 25C
(77F), -40 to 110C (-40F to 230F)), potentiometer (0 to
200k) or fan speed control. The thermistor bridge resistor is
12 k with a bridge supply 3.3 V.
Ethernet
RS232
USB
Example wiring
IQ4E
IQ4E
control
vINC vCNC1 CNC sCNC1 sCNC2
vCNC2 vCNC3 LAN
n n
Default CNC Addressing:The IQ4E device (outstation) n
address is factory-set (in the Address module) as follows:
Externally powered Loop powered The /230 version must be installed in a secondary enclosure
with a minimum protective rating of IP20 (or equivalent).
n n n n n
24V
n n IQ4E
AUX
IQ4E
IQ4E
Analogue Outputs(OUT11 to OUT16)
These provide a variable control voltage between 0 and 10Vdc.
IQ4E
The output can source up to 20 mA (see Combined Supply) DIN rail
and sink up to 3 mA. end stop
Example wiring
n
n n
Rotating clear polycarbonate covers provide access for the
power, communications and I/O connections.
Vdc
00V
V /230:This option requires a 230 Vac 10%, 50/60 Hz supply
The input power earth (ground) terminal is isolated from the
input power neutral, and must be separately earthed (grounded)
Auxiliary Supply Output locally; this ground terminal is internally connected to the IQ4E
electronics earth (ground).
This output can be used to supply I/O devices (e.g. sensors).
It provides 24 Vdc 5% from AUX terminals 70, 71 and 72, with The 230 V supply must include a dedicated 5 A fuse complying
a return through terminal 73 or any C terminal. with IEC60269 (BS1362) and a suitably rated switch in close
proximity and be clearly marked as the disconnecting device for
The maximum available current is internally limited as follows: the unit. A 5A circuit breaker with high breaking capacity may
be used as an alternative.
Auxiliary Output (AUX) Terminals E N L
70 71 72
120 mA shared 120 mA
5A
The available current also depends on other current demands
(see Combined Supply).
Combined Supply
The IQ4Es combined supply provides power for the:
Analogue outputs,
Auxiliary supply terminals,
Wallbus,
RS232 port, and
I/O Bus supply.
/24VAC:This option requires a 24 Vac 10%, 50/60 Hz, 44VA Current Loop(adjacent to current loop connector - operational
max or 48 Vdc +/- 15% 0.67A, 32 W supply. on /LAN variants only):
General(in centre of cover): The barcodes on both labels conform to the code 128 auto
format.
Indicator Colour Function
Power Green Condition of input power supply
Watchdog Red Presence of a firmware/strategy fault
LAN OK Green Status of the Trend LAN
(operational on /LAN variants only)
I/O Bus Green Status of connection to I/O modules
Service Yellow Service button activated. Flashes if
a powered device is connected to the
USB port when IQ4E is not powered
Timemaster
The IQ4E can act as a system Timemaster to synchronise the
time and date across the Trend system. It can use SNTP (simple
network time protocol) to obtain precision current time from an
unauthenticated NTP server on the Internet. Daylight saving
can be implemented automatically (via timezone setting) or
manually by specified dates and time adjustment.
alarms
The IQ4E will generate Network, General, and Item alarms.
Network alarms are generated by the Trend Network nodes,
General alarms are generated when the IQ4E detects a
problem within its own hardware or program, and Item alarms
are generated by the strategy, and are normally due to a faulty
plant condition.
For coded alarms the protocol limits the item number to 255
maximum. For text alarms the maximum item label length is
20 characters (although the 963 can be set up to use labels
previously learnt).
All alarms (except Network alarms) are also stored locally in the
Alarm Log. The alarm log can record up to 300 alarms. Once this
limit is reached each new alarm will overwrite the oldest record.
Language
The user can specify which language the IQ4E uses for the
display of web pages and for transmitted alarms. The standard
languages are in the controller as supplied. In the controller the
Address module has a language parameter which will be set
to the default language, but can be changed to any one of the
other available languages. The IQ4E can use languages which
require 8 bit code (i.e. special or accented characters) and can
also operate with right to left languages (e.g. Chinese, Arabic).
Identication
The IQ4E will identify itself as an IQ4 to w comms.
Strategy
In order to operate as a controller, the modules provided by the This produces a strategy file (filename.IQ4) that can be
firmware must be configured to define the way the controller downloaded to the controller to define its operation. This file
is to control the connected equipment. This configuration is consists of all the strategy module instances, their parameters,
known as the strategy. Strategies are configured using the and links. When this is downloaded it is stored in the controller
System Engineering Tool (IQSET). and then run using the controller firmware.
Field Maintenance
The IQ4E requires no routine maintenance.
WARNING: Contains no serviceable parts. Do
! not attempt to open the unit. Failure to comply
may cause damage to the unit.
DISPOSAL
COSHH (Control of Substances Hazardous to Health -
UK Government Regulations 2002) ASSESSMENT FOR WEEE Directive:
DISPOSAL OF IQ4E.
At the end of their useful life the packaging, and
RECYCLING . product should be disposed of by a suitable
All plastic and metal parts are recyclable. The printed circuit recycling centre.
board may be sent to any PCB recovery contractor to recover
some of the components for any metals such as gold and silver. Do not dispose of with normal household waste.
Do not burn.
Compatibility
Browsers: This device has been successfully tested with Controllers: IQ3/IQ4 directly and IQ1, IQ2, IQL by way of
Internet Explorer (v10 & 11), Chrome (v29.0.1547.0), Mozilla XTEND. IQ4E/../LAN communicates with IQ2, IQ1 directly.
Firefox (v23), Safari (v5.1.7) and with the default browser on the IQeco by way of IQ4NC.
following device operating systems:
Strategies: IQ1, IQ2, IQ3 can be imported into IQSET,
Apple iOS 8.1.3 converted into IQ4 strategies, and then downloaded into an
Android 5.0 Lollipop IQ4E. If the strategy file accesses I/O channels beyond those
Windows Phone 8.1 available in the IQ4E the strategy will be rejected.
It should work with all modern browsers, smart phones, and Ethernet Nodes:XTEND, NXIP, or EINC.
tablets (with JavaScript enabled) available at the date of release
of this product. Note: NXIP or EINC must not be used in an automatic IP
addressing (DHCP) environment.
Owing to the rapidly changing nature of web devices, new
devices and browsers will become available after the release of BACnet Devices:IQ4E Compatibility is defined in IQ4 Product
this product. If you would like to check the compatibility of IQ4E Implementation Conformance Statement (TP201248).
with your device, please connect to: iq4demo.trendcontrols.
com. Log in with username: mobile and password: trend.
Note: The NDP is not compatible with IQ4E; it will not recognise
an IQ4E connected to its network.
Installation
The IQ4E is designed to be clipped on to a standard TS35 DIN rail. The IQ4E must be installed in a secondary enclosure with a
minimum protective rating of IP20 (or equivalent). The /24VAC version can also be mounted outside normal reach (e.g. in a plenum).
A full description of installing the unit is given in the IQ4E/.., IQ4NC/16/.., IQ4NC/32/.. Installation Instructions - Mounting (TG201338)
and IQ4E/.. IQ4NC/16/..., IQ4NC/32/... Installation Instructions - Configuring (TG201339).
Order Codes
IQ4E/[CHAN]/[LAN]/BAC/[Power]
[CHAN] Number of supported I/O channels: 16, 32, 64, 96, 128, 160, 192
[LAN] Blank No Trend current loop
LAN Trend current loop option fitted
[Power] 230 230 Vac input power supply
24VAC 24 Vac/48 Vdc input power supply
UPGRADES
If the number of supported I/O channels needs to be increased, the following controller upgrades are available:
Note: An upgrade will only increase the number of I/O channels that are supported in the firmware; an upgrade does not change the
hardware. Additional I/O modules will be required to make use of the extra channels.
Accessories
IQ4/IO/.. Range of IQ4/IO modules - see IQ4/IO Modules Data Sheet (TA201341)
XCITE/IO/.. Range of XCITE/IO modules - see XCITE/IO Modules Data Sheet (TA201352)
Specifications
Electrical Supply Current :50 mA maximum*.
Number of Devices :up to 14 (subject to power loading)
Power Input
/230 :230 Vac 10% 50/60 Hz, 70 VA max. USB Local Engineering Port
/24VAC :24 Vac 10% 50/60Hz, 44 VA max or Transmission :USB 2.0.
:48 Vdc 15% 0.67A, 32 W Data Rate :480 Mbits/s (Hi-Speed).
Fusing :No replaceable fuses required. Distance :5 m (5 yards) maximum.
Power Failure Protection Address (sCNC2) :1 to 119, (2, 3 and 10 not permitted)
Strategy & data :non-volatile flash memory. settable in software.
Real time clock :supercap, maintained for up to 8 days
(typical). I/O Bus
Clock Accuracy :10 s per month (typical). Maximum Total Length :300 m (328 yds), using IQ4/IO modules
Cycle Time :Sequence table 1s. only;
30 m (33 yds), using IQ4/IO and/or
Ethernet Network XCITE/IO modules.
Transmission :10/100 BASE-T (IEEE 802.3). Maximum Modules :30 (IQ4/IO modules only);
Connection :RJ45, auto MDI-X. 15 (IQ4/IO and/or XCITE/IO modules).
Cable Type :Cat 5e, UTP (unshielded twisted pair). Maximum Channels :192 (including 16 onboard).
Distance (to hub) :100 m (109 yds) maximum. Bus Supply 24 Vdc 5%; 800 mA maximum*.
Virtual CNCs :3. Cable Type :Belden 3084A (up to 100 m);
Addresses :Not set by default set to desired value Belden 7895A (up to 300 m).
in range 1 to 119 (excluding 2, 3, & 10) For further details see:
using configuration mode. Address IQ4/IO Modules Data Sheet (TA201341);
must be unique on LAN. XCITE/IO Modules Data Sheet (TA201352).
Wallbus
Cable Type :Unscreened twisted pair.
Distance :60 m (200 ft) maximum.
Analogue Outputs I/O Bus :PCB edge connector for use with
Number of Channels :6. IQ4/IC/LINK rigid interconnector,
Function :Variable control from strategy of valve/ IQ4/IC/ADPT cable adapter, or IQ4/
damper actuators, voltage to current/ IC/TERM terminator.
pressure converters, relay modules, RS232 Supervisor Port :RJ11 (FCC68).
lighting dimmers, etc. Ethernet Port :RJ45 connector.
Voltage Range :0 to 10Vdc. USB Engineering Port :Micro B connector.
Current (maximum*) :up to 20 mA (source) or 3 mA (sink). USB Expansion Port :USB Type A (for future use)
Accuracy :0.5% of span.
Resolution :11 bit (2048 steps). Environmental
Auxiliary Supply Output EMC :EN61326-1:2013.
Voltage :24 Vdc 5%. Immunity :Table 2 - for equipment intended for
Current (maximum*) :120 mA shared between terminals 70 and use in industrial locations.
71, plus 120 mA from terminal 72. Emissions :Class B.
Safety :EN61010-1:2010.
*Available current may be affected by demands on other CB certificate
outputs - see Combined Supply on page 5. IQ4E/LAN/230 :NO90303
IQ4E/230 :NO90304
Indicators IQ4E/LAN/24VAC :TBD
IQ4E/24VAC :TBD
Power ( ) :Green LED Ambient limits
Watchdog ( ) :Red LED Storage :-25C (-13F) to +60C (+140F).
LAN OK ( ) :Green LED Operating :-25C (-13F) to +55C (+131F).
I/O Bus ( ) :Green/Red LED
Service Button ( ) :Yellow LED Note: For temperatures below 0C (32F) special care must
RX (current loop) :Yellow LED be taken that there is no condensation on or within the unit.
TX (current loop) :Yellow LED
OK (Ethernet) :Green LED Humidity :0 to 90%RH non-condensing.
RX (Ethernet) :Yellow LED Altitude :<4000 m (13124).
IN1 to IN10 :Yellow LED Pollution Degree :2 (Only non-conducting pollution
OUT11 to OUT16 :Yellow LED occurs).
Protection :IP20 if mounted in an enclosure rated
Mechanical at IP20 or equivalent.
Connectors
Power
Connector type :2 part connector with rising cage clamp
screw terminals.
Cable size :0.14 to 2.5 mm2 (22 to 12 AWG).
Inputs/Outputs, Current Loop, Wallbus & AUX (power out).
Connector type: :2 part connector (0.2 pitch) with rising
cage clamp screw terminals.
Cable size :0.14 to 2.5mm2 (22 to 12 AWG)
iPad and iPhone are trademarks of Apple Inc., registered in the U.S. and other countries. Android is a trademark of Google Inc.
Windows is either a registered trademark or trademark of Microsoft Corporation in the United States and/or other countries
Please send any comments about this or any other Trend technical
publication to [email protected]
2016 Honeywell Technologies Srl, ECC Division. All rights reserved. Manufactured for and on behalf of the Environmental and Combustion Controls
Division of Honeywell Technologies Srl, Z.A. La Pice, 16, 1180 Rolle, Switzerland by its Authorized Representative, Trend Control Systems Limited.
Trend Control Systems Limited reserves the right to revise this publication from time to time and make changes to the content hereof without obligation
to notify any person of such revisions or changes.
Trend Control Systems Limited
Albery House, Springfield Road, Horsham, West Sussex, RH12 2PQ, UK. Tel:+44 (0)1403 211888 Fax:+44 (0)1403 241608 www.trendcontrols.com