PV2000 Series
Valveplate
Modulating Pumps
Also refer to "Pump Features, Selection and Operating
Recommendations" (dynexpumpoperating.pdf)
CONTACT INFORMATION
USA Headquarters
Dynex/Rivett Inc.
770 Capitol Drive
Pewaukee, WI 53072 U.S.A.
Tel: 262-691-2222
FAX: 262-691-0312
E-mail: [email protected]
European Sales
Dynex/Rivett Inc.
Unit C5 Steel Close, Little End Road, Eaton Socon,
Huntingdon, Cambs. PE19 8TT United Kingdom
Tel: +44 (0) 1480 213980
FAX: +44 (0) 1480 405662
E-mail: [email protected]
BROCHURE NOTES:
Maximum pressures indicated throughout are the maximum intermittent pressures a component can
sustain for occasional, short periods of operation without appreciably reducing the life expectancy.
Contact the Dynex sales department for a review of any application which requires operating above
the rated pressures, flows, speeds or higher than normal operating temperatures.
Specifications shown were in effect when published. Since errors or omissions are possible, contact
your sales representative for the most current specifications before ordering. Dynex reserves the right
to discontinue products or change designs at any time without incurring any obligation.
ENERGY-SAVING CONTROLS
Pressure compensation and load sensing
CONTAMINATION match system requirements
TOLERANT BARREL
Special anti-galling coating
provides long service life
ELECTRO-HYDRAULIC CONTROL
Modulating models deliver flow
proportional to variable input signal
2
PV2000 SERIES PUMPS
Reliable Modulating
Pumps For Long,
Difficult Duty Cycles
PV2000 Series pumps, with their
durable construction yet simple
electro-hydraulic design, provide
long, reliable service life.
Modulating pumps, with accurate
output, feature a patented design
requiring no additional electronic feed-
back. The rugged design provides
dependable operation in adverse
conditions including extreme heat, dirty
environments and difficult duty cycles.
PV2000 Series pumps are available Model PV2024: Resistance 24.5 Ohms
in three displacements, with a choice 17.7 U.S. gpm (67,0 L/min); Wattage 5.9 Watts
of controls: Model PV2029: Inductance at 1.0 kHz 60 mH
21.5 U.S. gpm (81,4 L/min);
Pressure Compensation Model PV2032: Recommended 3 V (D.C.) 60 Hz
Maintains a preset maximum pressure, Dither Signal Square Wave
24.5 U.S. gpm (92,7 L/min)
adjustable from 500 to 3500 psi (35 to Specifications at 70 F (21 C)
245 bar). These models include an See Typical Performance Curves A dither signal is recommended to improve
integral stroke limiter for convenient on page 8 for maximum output. response time and reduce hysteresis. A pulse
width modulation signal can also be used to
adjustment of maximum pump output. improve performance.
3
PV2 SERIES PUMP OPERATION
signal. 75
FLOW (%)
The armature controls the movement
ACCURATE OUTPUT FLOW of a pilot spool which ports pilot flow to 50
Modulating models deliver flow pro- the pump control piston. An external 25
por tional to a variable electrical pilot supply of 0.2 gpm at 200 psi CLOCKWISE
ADJUSTMENT
signal supplied to a force motor in the (0,8 L/min at 13,8 bar) is required. 0
OFF-STROKE FULL-STROKE
pilot-stage. The force motor is an The pump cradle in these models is VOLTAGE VOLTAGE
CONTROL PISTON
FEEDBACK CAM
Figure 2: Pilot flow ported through control orifice Figure 3: Movement of sleeve nulls pilot stage
4
PV2000 SERIES PUMPS
MODEL SELECTION
Clockwise Rotation Counter-Clockwise Rotation
Shaft Pump Control
17.7 U.S. gpm 21.5 U.S. gpm 24.5 U.S. gpm 17.7 U.S. gpm 21.5 U.S. gpm 24.5 U.S. gpm
(S.A.E. B-B) Description
(67,0 L/min) (81,4 L/min) (92,7 L/min) (67,0 L/min) (81,4 L/min) (92,7 L/min)
at 1800 rpm at 1800 rpm at 1800 rpm at 1800 rpm at 1800 rpm at 1800 rpm
5
PV2000 SERIES PUMPS
Installation and
.25 (6,4) INT. HEX
Performance Data (ADJUSTMENT
FOR CRADLE STOP)
-40 F
Pour Point, 0 F
(-40 C)
Typical (-17,8 C)
or Less
Viscosity 95 95 .25 (6,4) INT. HEX
(ADJUSTMENT
Index Minimum Minimum FOR CRADLE STOP)
6
PV2000 SERIES PUMPS
60
40
50
INPUT POWER
)
KE
KE
) RO
RO ST
30 40 ST LL
L (FU
(F UL ER
ER OW
OK
E) OW TP
30 TR TP PU
S U IN
20 (FU
LL INP
R
WE
PO
20 UT
INP
10
10
ATED)
PENSATED) INPUT POWER (COMPENS
INPUT POWER (COMPENSATE
D) INPUT POWER (COM
0 0
N M LB IN
250 2250
2000
200 1750
INPUT TORQUE
1500 KE
)
KE
) RO
150 RO ST
1250 E) ST LL
K L FU
T RO UL U E(
S (F RQ
LL UE TO
1000 (FU RQ
UE TO UT
100 O RQ
PU
T INP
750 U TT IN
INP
500
50
250
0 0
U.S.
L/MIN. GPM
100
DELIVERY AT 1800 RPM
90 24
DELIVERY AT 1800 RPM
80
20
DELIVERY AT 1800 RPM
70
DELIVERY
60 16
50
12
COMPENSATOR COMPENSATOR COMPENSATOR
40 SETTING
AT 2500 PSI
SETTING
AT 2500 PSI
SETTING
AT 2500 PSI
175 BAR 175 BAR 175 BAR
AT 1500 PSI AT 1500 PSI AT 1500 PSI
30 8 105 BAR 105 BAR 105 BAR
20
4
10
0 0
100
VOLUMETRIC VOLUMETRIC VOLUMETRIC EFFIC
EFFICIENCY EFFICIENCY IENCY
90
OVERALL EFFICIENCY
80 OVERALL EFFICIENCY OVERALL EFFICIENCY
EFFICIENCY %
70
60
50
40
30
20
10
0
PSI 1000 2000 3000 4000 PSI 1000 2000 3000 4000 PSI 1000 2000 3000 4000